    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    Implant System – Zirconia Implant System, K231803 Neodent Implant System – Zirconia Implant System, K101945

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Zirconia Implants:
    The Neodent Implant System is intended to be surgically placed in the bone of upper or lower jaw to provide support for prosthetic devices, such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage surgical procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with physiological occlusion loading. Multiple teeth applications can be rigidly splinted. The implants with length of 5 mm (short implants) may be used only with two-stage surgical procedures. The recommended healing time before loading is between 10 to 12 weeks.

    Zi Transmucosal Cover Screw and Healing:
    The Neodent Implant System is intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices, such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage surgical procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with physiological occlusal loading. Multiple teeth applications can be rigidly splinted.

    Zi Transmucosal Provisional Coping:
    The Neodent Implant System is intended for surgical procedures in maxilla or mandible, providing support for prosthetic devices such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single- or multi-unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading.

    Zi Transmucosal Abutment Replacement Screw:
    The Neodent Implant System is intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices, such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading.

    Zi Transmucosal Universal Base:
    The Universal Ceramic Base Zi Transmucosal 5.0 is an abutment placed over Neodent Zi Transmucosal 5.0 Ceramic Implant System in order to provide support for custom-made prosthetic restorations, such as copings or crowns. It may be used for cement or screw-retained single unit restorations. All digitally designed copings and/or crowns to be used with the Neodent Zirconia Base Abutment System are intended to be sent to Straumann for manufacture at a validated milling center.

    Zirconia Base for Bridge:
    The Zirconia Base for Bridge is an abutment placed over Neodent Zirconia Implants in order to provide support for custom-made prosthetic restorations. It may be used for cement or screw-retained multi-unit restorations. All digitally designed copings and/or crowns to be used with the Neodent Zirconia Base Abutment System are intended to be sent to Straumann for manufacture at a validated milling center.

    Zirconia Base C:
    The Zirconia Base C is an abutment placed over Neodent Zirconia Implants in order to provide support for customized prosthetic restorations, such as copings or crowns. It may be used for single-unit restorations that are screw- or cement-retained in esthetic areas over implants installed in the maxilla or mandible. All copings and/or crowns digitally designed for use with the Titanium Base C are to be designed using Sirona inLab software or Sirona CEREC Software and manufactured using a Sirona CEREC or inLab MC X or MC XL milling unit.

    Device Description

    This premarket notification includes new ceramic devices into Neodent Implant System, which are compatible with Zirconia Implant System. The Zirconia Implants and Abutments proposed on this submission are similar to devices already cleared in previous submissions of Neodent Implant System – Zirconia Implant System, according to predicate devices described above. This submission intends to expand the portfolio with new solutions and diameter, in order to provide more treatment options to the customers.

    The Zirconia Implants are manufactured in Zirconia Y-TZP and are available in Bone Level (BL) or Tissue Level (TL or Transmucosal) configurations. The Zirconia Implants (BL) are available in a diameter of 5.0 mm and lengths in a range of 8 to 13 mm. The Zi Transmucosal Implants (TL) are available in a diameter of 5.0 mm and lengths in a range of 5 to 11.5 mm.

    The Zi Transmucosal Healing and Cover Screw are temporary abutments manufactured in PEEK and used during the healing phase. They are compatible with the Zi Transmucosal Implants Ø5.0. The Zi Transmucosal Healing Abutment is available in the heights of 2 and 3.5mm.

    The Zi Transmucosal Provisional Coping is a temporary abutment made of polycarbonate (PC) and has a double function: used for molding procedures or production of provisional restoration.

    The Zi Transmucosal Abutment Replacement Screw is a prosthetic component manufactured in titanium alloy and used to fix the fix the Zi Transmucosal Base to the Zi Transmucosal Implant.

    The Zi Transmucosal Universal Base is a two-piece abutment of base and top-half prosthetic structure to provide support for customized single-unit restorations over Zi Transmucosal Implant (TL). The base is manufactured in Zirconia Y-ZTP and used with a patient-specific top-half prosthetic structure. The two-piece abutment has a cementable portion of 4mm and is available with gingival heights of 0.3, 1.0 and 1.5 mm. The top-half prosthetic structure to be used with Zi Transmucosal Universal Base must be designed and milled in a Straumann Validated Milling center, using the following restoration materials and dimensions:
    Material: IPS e.max CAD HT, Associated Material 510(k): K132209, Minimum wall thickness: 0.9 mm, Maximum angulation: 30°
    Material: IPS e.max CAD LT, Associated Material 510(k): K132209, Minimum wall thickness: 0.9 mm
    Material: N!ce, Associated Material 510(k): K171773, Minimum wall thickness: 1.0 mm
    Material: IVOCLAR Multilink cement, Associated Material 510(k): K130436, Minimum wall thickness: N/A
    Material: Zirconia N!ce® LT, Associated Material 510(k): K222836, Minimum wall thickness: 0.4 mm
    Material: Zirconia N!ce® HT, Associated Material 510(k): K222836, Minimum wall thickness: 0.4 mm
    Material: Zirconia N!ce® XT, Associated Material 510(k): K222836, Minimum wall thickness: 0.4 mm
    Material: PMMA N!ce, Associated Material 510(k): K071548, Minimum wall thickness: 0.7 mm
    Material: Panavia—Kuraray Cement, Associated Material 510(k): K150704, Minimum wall thickness: N/A, Maximum angulation: N/A

    The Zi Base for Bridge is a two-piece abutment of base and top-half prosthetic structure to provide support for customized multi-unit restorations over Zirconia Implants (BL). The base is manufactured in Zirconia Y-ZTP and used with a patient-specific top-half prosthetic structure. The two-piece abutment has a cementable portion of 4mm and is available with gingival heights of 1.5, 2.5 and 3.5 mm. The top-half prosthetic structure to be used with Zi Base for Bridge must be designed and milled in a Straumann Validated Milling center, using the following restoration materials and dimensions:
    Material: Zirconia N!ce® LT, Associated Material 510(k): K222836, Minimum wall thickness: 0.4 mm, Maximum angulation: 30°
    Material: Zirconia N!ce® HT, Associated Material 510(k): K222836, Minimum wall thickness: 0.4 mm
    Material: Zirconia N!ce® XT, Associated Material 510(k): K222836, Minimum wall thickness: 0.4 mm
    Material: PMMA N!ce, Associated Material 510(k): K071548, Minimum wall thickness: 0.7 mm
    Material: Panavia—Kuraray Cement, Associated Material 510(k): K150704, Minimum wall thickness: N/A, Maximum angulation: N/A

    The Zi Base C is a two-piece abutment of base and top-half prosthetic structure to provide support for customized single-unit restorations over Zirconia Implants (BL). The base is manufactured in Zirconia Y-ZTP and used with a patient-specific top-half prosthetic structure. The two-piece abutment has a cementable portion of 4mm and is available with gingival heights of 1.5, 2.5, 3.5 and 4.5 mm. The top-half prosthetic structure to be used with Zi Base C must be designed and milled in a Sirona InLab Validated Workflow, using the following restoration materials and dimensions:
    Material: IPS e.max CAD, Associated Material 510(k): K132209, Minimum wall thickness: 0.9 mm, Maximum angulation: 20°
    Material: IVOCLAR Multilink cement, Associated Material 510(k): K130436, Minimum wall thickness: N/A, Maximum angulation: N/A

    All these abutments have an internal connection with the implants (ZiLock) and the prosthetic platform is identical for all subject devices described in this submission. They are intended for single use and provided sterile via Ethylene Oxide method, along with undergoing moist heat sterilization after end-user customization.

    AI/ML Overview

    The provided FDA 510(k) clearance letter and its associated summary for the Neodent Implant System - Zirconia Implant System contain extensive information about the device, its intended use, and comparisons to predicate devices. However, it does not include specific acceptance criteria with numerical thresholds directly stated within the tables, nor does it detail a study that directly proves the device meets such criteria in terms of performance metrics like sensitivity, specificity, or image quality assessments.

    Instead, the submission focuses on demonstrating substantial equivalence to predicate devices through various tests, implying that if the new device performs similarly to or better than previously cleared devices, it meets the necessary standards. The performance testing section describes the types of tests conducted (e.g., dynamic fatigue, torsion, insertion, pull-out, and software validation), but it does not present clear quantitative acceptance criteria or the specific performance results in a comparative table format.

    Therefore, many of the requested fields cannot be directly extracted from the provided text as they pertain more to the performance evaluation of AI/software in interpreting medical images, which is not the primary focus of this dental implant submission.

    Here's an attempt to answer the questions based on the available information, noting where information is not explicitly provided in the document:


    Acceptance Criteria and Device Performance Study for Neodent Implant System - Zirconia Implant System

    The FDA 510(k) summary for the Neodent Implant System - Zirconia Implant System focuses on demonstrating substantial equivalence to predicate devices through a combination of bench testing, software validation, MRI compatibility, biocompatibility, and sterilization validation. It does not present specific quantitative acceptance criteria or performance metrics directly from a comparative study in the way one might expect for an AI/software-based medical device (e.g., sensitivity, specificity thresholds). Instead, the "acceptance criteria" are implicitly met by demonstrating that the proposed devices perform at a level substantially equivalent to legally marketed predicate devices under standardized testing conditions.

    1. A table of acceptance criteria and the reported device performance

    As mentioned, explicit numerical acceptance criteria and reported device performance in a comparative table (e.g., for diagnostic accuracy) are not provided in this 510(k) summary. The summary indicates that tests were conducted according to relevant ISO standards and FDA guidance, and the results demonstrated that the subject devices exhibit a level of performance substantial equivalent to the predicate and reference devices.

    Below is a conceptual table based on the types of tests mentioned, noting that specific numerical acceptance criteria and performance data are not detailed in the provided text.

    Acceptance Criteria Category (Implicit)Standard/GuidanceReported Device Performance (Summary)
    Dynamic Fatigue StrengthISO 14801, FDA Guidance (Class II Special Controls)Demonstrated a level of performance substantial equivalent to predicate and reference devices in identical conditions.
    Torsion StrengthNot specifiedAdequate torsion strength in accordance with recommended IFU installation torque.
    Insertion TorqueNot specifiedEvaluated insertion torque in sawbones material (Bone type I, II, III, IV). (Specific values not given).
    Implant Surface Area & Pull-Out StrengthNot specifiedGreater surface area compared to reference devices; higher resistance values in Pull Out Test.
    Software Validation (Sirona Digital Workflow)Not specifiedAccuracy requirement was met; critical design parameters (min wall thickness, max angulation) respected and monitored.
    MRI CompatibilityK182620, FDA GuidanceMR conditional labeling from K182620 is applicable; safe for scanning under previously established parameters.
    BiocompatibilityISO 10993-1, ISO 10993-18, ISO 10993-5, FDA GuidanceSubject devices are equivalent in material and manufacturing processes to predicates; no new issues raised; no additional testing required.
    Sterilization Validation (Ethylene Oxide)ISO 11135:2014Validated to a Sterility Assurance Level (SAL) of 1x10⁻⁶; residuals below max allowable limits per ISO 10993-7.
    Sterilization Validation (Moist Heat)ISO 17665-1Validated using parameters described in IFU.
    Endotoxin TestANSI/AAMI ST72:2011, ISO 11737-3, US Pharmacopeia chapter 85Results <0.05 EU/device.
    Shelf LifeNot specifiedDetermined to be 5 years; packaging identical to predicates.

    2. Sample size used for the test set and the data provenance

    The document details various bench tests (dynamic fatigue, torsion, insertion, pull-out) and validation studies (software, MRI, biocompatibility, sterilization, endotoxin, shelf-life). However, specific numerical sample sizes ("n=") for these individual tests are not provided in the summary. For example, for dynamic fatigue testing, it states "the results demonstrated that...". It doesn't specify how many implants or setups were tested.

    • Data Provenance (Country of Origin): The submitter is JJGC Indústria e Comércio de Materiais Dentários S.A. (dba Neodent) based in Curitiba, Paraná, Brazil. The tests are generally conducted to international ISO standards and FDA guidance, but the location where the tests were performed is not explicitly stated for each test beyond the company's Brazilian location.
    • Retrospective or Prospective: Not applicable in the context of bench testing and validation studies as described. These are laboratory-based tests rather than clinical studies on patient data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    This information is not applicable and not provided in the context of this 510(k) submission. The device is a dental implant system (hardware), not an AI/software device that interprets medical images requiring expert-established ground truth for a test set. The validation processes involve standardized engineering and biological tests as opposed to expert review of clinical cases.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This information is not applicable and not provided. As explained above, the submission pertains to a hardware device, not an AI/software system requiring human adjudication for ground truth establishment.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This information is not applicable and not provided. This type of study is relevant for AI-assisted diagnostic tools, not for dental implant hardware.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This information is not applicable and not provided. This concept is specific to AI/software performance, not a physical dental implant system. The "software validation" mentioned is for the compatibility of milling units (CAD/CAM workflow), ensuring design parameters are respected, not for an AI algorithm interpreting dental images.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    For the bench tests, the "ground truth" is defined by compliance with established engineering standards (e.g., ISO 14801 for dynamic fatigue) and specifications (e.g., material properties, dimensions). For biological safety, it's compliance with ISO 10993. For the CAD/CAM software, it's the accurate adherence to design parameters. This isn't "ground truth" in the diagnostic sense, but rather adherence to predefined engineering and biocompatibility specifications.

    • Clinical Literature Review: A clinical literature review was conducted to support the safety of Zi Transmucosal Implant less than 7mm of length, referencing animal studies and histomorphometry evaluation. This aligns with outcomes data or pathological/histological evidence from preclinical studies, suggesting "similar osseointegration outcomes" and "ability to promote bone formation around them in a manner equivalent to titanium implants."

    8. The sample size for the training set

    This information is not applicable and not provided. This concept is specific to machine learning/AI models, which are not the subject of this 510(k) submission.

    9. How the ground truth for the training set was established

    This information is not applicable and not provided. As above, this is relevant for AI/ML training data, not for a physical dental implant system.

    Ask a Question

    Ask a specific question about this device

    K Number
    K242686

    Validate with FDA (Live)

    Date Cleared
    2024-12-04

    (89 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    NeoConvert Solution: The Neodent Implant System is intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices, such as artificial teeth, to restore chewing function. The NeoConvert Solution may be used with single-stage or two-stage procedures, for temporary multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading.

    Direct Screw to MUA: The Neodent Implant System is intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices, such as artificial teeth, to restore chewing function. The Direct Screw to MUA may be used with single-stage or two-stage procedures, for screw-retained multi-unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading. All digitally designed personalized copings to be used with the Direct to Multi Unit Abutment Screw are intended to be sent to Straumann for manufacture at a validated milling center.

    GM Attachment TiN 30°: The Neodent Implant System is intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices, such as artificial teeth, to restore chewing function. The GM Attachment TiN 30° may be used with single-stage or two-stage procedures, for multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading.

    Device Description

    This premarket notification includes the following additions to the Neodent Implant System: NeoConvert Solution, Direct Screw to MUA, GM Attachment TiN 30°. The Neodent Multi-Unit Abutments proposed on this submission are similar to devices already cleared in previous submissions of Neodent Implant System, according to predicate devices described above. This submission intends to expand the portfolio of Neodent Abutments with these new solutions for multi-unit restorations, to provide more treatment options to customers. The NeoConvert Solution is a technique comprised by some abutments (not subject of this submission) used for converting removable temporary prosthesis into a screw-retained fixed temporary prosthesis. The Direct Screw to MUA is a prosthetic component designed to fix planned and digitally designed multi-unit milled restorations directly onto mini or micro abutments, eliminating the need for using the passive seating cylinder to restore chewing function. The GM Attachment TiN 30° is a prosthetic component used to stabilize implant-mucosa-supported removable full prosthesis (retained on the implant and supported on the mucosa), on implants installed in the maxilla or mandible. Although all these three new solutions are compatible with the same implants and components of Neodent Implant System and used for multiple unit rehabilitation, they are not used in conjunction with each other.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the "Neodent Implant System," focusing on the NeoConvert Solution, Direct Screw to MUA, and GM Attachment TiN 30°. This document details the device's technical characteristics, intended use, and its substantial equivalence to previously cleared predicate devices.

    However, the provided text does not contain information about acceptance criteria and a study proving a device meets those criteria in the context of an AI/ML medical device submission. The document is a traditional 510(k) submission for dental implants and abutments, which are physical medical devices, not AI/ML software. Therefore, the specific requirements for an AI/ML device study (such as sample sizes for test and training sets, expert qualifications for ground truth, MRMC studies, or standalone performance) are not applicable or present in this document.

    The "Performance Testing" section (pages 15-16) describes bench testing (dynamic fatigue, torsion, SEM images), MRI compatibility testing, biocompatibility testing, sterilization validation, and shelf-life testing for the physical dental implant components. These are standard performance tests for this type of physical device, not AI/ML algorithm validation.

    Therefore, I cannot provide a table of acceptance criteria and a study proving the device meets acceptance criteria as typically outlined for an AI/ML medical device, as this information is not present in the provided document. The document focuses on demonstrating substantial equivalence of a physical dental device to predicate devices through engineering and material testing.

    Ask a Question

    Ask a specific question about this device

    K Number
    K210336

    Validate with FDA (Live)

    Date Cleared
    2021-08-13

    (189 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K151328, K101945, K182620

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Neodent Implant System is intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices, such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage surgical procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with physiological occlusal loading. Multiple teeth applications can be rigidly splinted.

    The CR Abutment is an abutment placed over Neodent Zirconia Implants in order to provide support for prosthetic restorations, such as copings or crowns. It may be used for single-unit restorations that are cement-retained in esthetical areas over implants installed in maxilla or mandible.

    Device Description
    • Intended for single use;
    • Provided sterile via Ethylene Oxide;
    • . All devices of Zirconia Implant System are manufactured of Y-TZP (Yttrium-stabilized zirconium dioxide);
    • . The CR Abutment for Zirconia system is supplied along with a titanium alloy screw (ASTM F136);
    • ZiLock prosthetic interface with internal indexer;
    • Apically tapered implant with trapezoidal thread profile;
    • Implant provided with sand-blasted, acid etched surface finish;
    • . The subject Implants are compatible with the Zirconia Bases (already cleared per market per K201491) and CR Abutments (subject of this submission);
    • . The subject CR Abutments are compatible with the Zirconia Implants 4.3 mm (already cleared per market per K201491) and Zirconia Implants 3.75 mm (subject of this submission).
    AI/ML Overview

    This document describes the Neodent Implant System - Zirconia Implant System (K210336), which includes Zirconia Implants and CR Abutments. The submission aims to demonstrate substantial equivalence to previously cleared predicate devices.

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document doesn't explicitly refer to "acceptance criteria" in the traditional sense of numerical thresholds for a study endpoint. Instead, the performance data presented aims to demonstrate equivalence to predicate devices through various tests.

    Test TypeAcceptance Criteria (Implied)Reported Device Performance
    BiocompatibilityCompliance with ISO 10993-1 and ISO 10993-18. Not representing a new worst-case compared to K201491.Biological Safety Assessment guided by ISO 10993-1 performed. Chemical characterization per ISO 10993-18 performed. Subject devices do not represent a new worst-case, relying on results from K201491.
    Dynamic Fatigue TestEquivalent fatigue strength to predicate devices per ISO 14801 and FDA Guidance.Performed according to ISO 14801. Devices exhibit a level of performance equivalent to that reviewed for the predicate devices. SEM images after fatigue show similar wear to K201491.
    Torsion TestSufficient resistance to static torsional loading.Performed to evaluate the Zirconia Implant System under static torsional loading. (Specific quantitative results not provided in this summary).
    Insertion TestAcceptable insertion torque into different bone types.Performed to evaluate insertion torque into sawbones material representing bone types I, II, III, and IV. (Specific quantitative results not provided in this summary).
    Screw Torque TestingNo visible failure after torque application and removal.Performed with torque application and visual analysis. No visible failure identified after applying torque and removing items. Subject screws considered equivalent to those cleared per K201491.
    Sterilization ValidationSterility Assurance Level (SAL) of 1x10^-6 via Ethylene Oxide (ISO 11135-1). Not representing a new worst-case compared to K201491.Sterilized by Ethylene Oxide per ISO 11135-1 (over-kill method). Achieved an SAL of 1x10^-6. Subject devices do not represent a new worst-case, adopting the method from K201491.
    Bacterial Endotoxin TestingResults < 0.05 EU/device per ANSI/AAMI ST72:2011.Performed on representative samples. Obtained results were <0.05 EU/device.
    MR Conditional LabelingLeveraging of existing K182620 labeling.MR Conditional Labeling was leveraged from K182620.
    Shelf Life5 years of product and package stability.Validated per ASTM F1980. Shelf life determined to be 5 years.

    2. Sample Size Used for the Test Set and Data Provenance:

    The document does not explicitly state the specific numerical sample sizes for each individual test conducted for the subject device. It refers to "representative samples" for biocompatibility and bacterial endotoxin testing, and studies conducted based on "FDA Guidance" and ISO standards.

    • Data Provenance: The document does not specify the country of origin of the data or whether the studies were retrospective or prospective. The manufacturer, JJGC Indústria e Comércio de Materiais Dentários SA, is located in Curitiba, Parana, Brazil.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts:

    This information is not applicable and not provided in the document. The document describes engineering and laboratory testing for device performance, not a clinical study involving diagnosis or interpretation by experts to establish ground truth.

    4. Adjudication Method:

    This information is not applicable and not provided in the document. As mentioned above, it's not a clinical study requiring adjudication of expert opinions.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done:

    No, an MRMC comparative effectiveness study was not done. The submission focuses on demonstrating substantial equivalence through non-clinical performance testing.

    6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) was Done:

    No, this question is not applicable. The device is a physical dental implant system, not a software algorithm.

    7. The Type of Ground Truth Used:

    The "ground truth" for the performance tests is derived from established engineering standards, material specifications, and regulatory guidance. For example:

    • Biocompatibility: ISO 10993 standards and a comparison to previously cleared (predicate) device data.
    • Mechanical Testing: ISO 14801 standard and comparison to predicate device performance.
    • Sterilization: ISO 11135-1 standard achieving a specific SAL.
    • Bacterial Endotoxin: ANSI/AAMI ST72:2011 standard.
    • Shelf Life: ASTM F1980 standard.

    8. The Sample Size for the Training Set:

    This information is not applicable as the device is a physical medical device, not an AI/ML algorithm that requires a training set.

    9. How the Ground Truth for the Training Set was Established:

    This information is not applicable as the device is a physical medical device, not an AI/ML algorithm.

    Ask a Question

    Ask a specific question about this device

    K Number
    K192839

    Validate with FDA (Live)

    Date Cleared
    2021-02-11

    (504 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The DSP Implant System is intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices, such as artificial teeth, to restore chewing function. It may be used with single stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading.

    Device Description

    DSP Implant System is composed of the External Hex (HE) implant line is composed of implants and related prosthetic components available in multiple designs. DSP implants are made of commercially pure titanium (ASTM F67). DSP prosthetic components are made of commercially pure titanium or cobalt-molybdenum alloy (ASTM F1537). DSP implant system screws (abutment and prosthetic screws) are made of titanium alloy (ASTM F136). The HE implant line is named after the External Hex implant-to-abutment interface. It is subdivided in External Hex SLIM (HE SLIM), External Hex BIOFIT), External Hex SOULFIT (HE SOULFIT), External Hex PROPFIT (HE PROPFIT) and External Hex WAYFIT). The HE implants are bone-level implants. The subject device abutments components mate exclusively with the subject implants of the same line.

    AI/ML Overview

    This is a 510(k) summary for the DSP Implant System, a dental implant device. It establishes substantial equivalence to various predicate devices rather than providing performance data against specific acceptance criteria for the new device. Therefore, it does not present a typical study design with acceptance criteria and results in the way a clinical trial or device performance study would.

    However, based on the provided text, we can infer the approach taken by the manufacturer to demonstrate substantial equivalence, which serves as their "proof" that the device meets regulatory requirements.

    Here's an interpretation of the requested information based on the 510(k) summary:

    1. A table of acceptance criteria and the reported device performance

    Since this is a 510(k) submission focusing on substantial equivalence, there isn't a table of discrete acceptance criteria and reported device performance in terms of clinical outcomes or specific quantitative measures as one might find in a standalone performance study. Instead, the "acceptance criteria" are implied by the characteristics of the legally marketed predicate devices, and the "reported device performance" is the demonstration that the subject device shares these characteristics or has equivalent performance as validated through non-clinical testing.

    The acceptance is based on demonstrating that the DSP Implant System is substantially equivalent to the predicate devices in terms of:

    • Intended Use: The indications for use statement of the subject device is equivalent to the primary predicate device K101207, and within the scope of reference devices.
    • Technological Characteristics: The subject device's design features, materials (CPTi Gr4, CoCr, POM, Ti6Al4V-ELI), sterilization methods (irradiation), and surface treatments (grit-blasted and acid-etched, machined collar) are compared to the predicate and reference devices. Minor differences are justified as not raising new questions of safety or effectiveness.
    • Performance: Non-clinical testing demonstrates that the device performs comparably to the predicate devices in relevant areas for dental implants.

    Implicit Acceptance Criteria and Reported Device Performance (based on substantial equivalence justification):

    Acceptance Criteria (Implied from Predicate Device Characteristics)Reported Device Performance (DSP Implant System's Characteristics & Non-Clinical Testing)
    Intended Use: Support prosthetic devices (artificial teeth) to restore chewing function; single-stage or two-stage procedures; single/multiple unit restorations; immediate loading with good primary stability and appropriate occlusal loading.Equivalent: "The DSP Implant System is intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices, such as artificial teeth, to restore chewing function. It may be used with single stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading." (Matches K101207, with one phrase "multiple tooth application may be rigidly splinted" removed as it's a technique choice).
    Implant-to-Abutment Connection: e.g., External Hex (HE).Equivalent: HE connection for all subject implants (HE SLIM, HE BIOFIT, HE SOULFIT, HE WAYFIT, HE PROPFIT) and abutment components (CoCr Base UCLA, CoCr UCLA, Titanium Abutments, Mini Conical Abutments, Anatomical Abutments, O'ring Abutment, Temporary Coping, CoCr Base Coping, One Step Hybrid Coping).
    Raw Materials: Commercially Pure Titanium (CPTi Gr4), Titanium alloys (ASTM F136), Cobalt-Chromium alloys, Polyoxymethylene (POM).Equivalent: Implants are CPTi Gr4. Prosthetic components use CPTi Gr4, CoCr alloy, CoCr/POM, and Ti alloy (ASTM F136). These match or are comparable to predicate/reference device materials.
    Surface Treatment: Grit-blasted and acid-etched (and/or machined collar).Equivalent: Implants are treated. Grit-blasted and acid-etched. Machined collars are specified (e.g., h 1.0 mm for HE SLIM, h 0.3 mm for HE BIOFIT). EDS analysis confirmed no contaminating metal particles.
    Sterilization: Sterile by irradiation (or ethylene oxide for predicates).Equivalent/Validated: Provided sterile by irradiation. Sterilization validated according to ISO 11137-1, ISO 17665-1, ISO 17665-2. Sterile barrier shelf life testing (ASTM F1980), package integrity (ASTM F1929, ASTM F88/F88M), sterility of content (ISO 11737-2).
    Biocompatibility: Materials are biocompatible.Validated: Biocompatibility of materials supported by testing according to ISO 10993-5 (likely ISO 10993-1 as well, given the guidance document reference).
    Pyrogenicity: Device is non-pyrogenic.Validated: Pyrogenicity monitoring according to AAMI/ANSI ST72. Bacterial Endotoxin Test (BET) performed according to USP <85> using photometric technique. Representative samples selected for testing.
    Dimensions/Geometry: Range of diameters and lengths for implants and abutments.Equivalent: Tables 5.2-5.17 detail the diameter and length ranges for various implants and abutments, comparing them to predicate/reference devices. The text explicitly states that the subject implants and abutments are "substantially equivalent" to predicate/reference devices in design and range of dimensions, with specific predicate/reference devices covering particular dimensions or features. For example, K101207 covers 17mm length for HE SLIM, while K170398 covers other dimensions and body geometrical features.
    Functional Equivalence: e.g., Screw-retained, Cement-retained, Overdenture prosthesis attachment; Single-unit, Multi-unit restoration.Equivalent: All subject implants and abutments support screw-retained, cement-retained, and/or overdenture prosthesis attachment, and single-unit or multi-unit restorations, consistent with the predicate devices.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample Size for Test Set: Not applicable for a typical clinical or performance study as presented in this 510(k). The "testing" referred to is non-clinical bench testing (sterilization, biocompatibility, pyrogenicity, material analysis). These tests typically use a representative sample size specified by the relevant standard (e.g., a certain number of devices for sterility testing). The document does not specify these individual sample sizes.
    • Data Provenance: The data is non-clinical (bench testing) and generated by the manufacturer to support device characteristics. The 510(k) is submitted by a Brazilian manufacturer (D.S.P. Industrial Eireli) and prepared by a Brazilian regulatory affairs specialist (PR Servicos Regulatorios Administrarivos Ltda). The location of the actual testing labs is not specified. The studies are not clinical, so concepts like "retrospective" or "prospective" do not apply.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • Not applicable. This is a non-clinical submission. Ground truth, in the sense of expert opinion on clinical data, is not established. The "ground truth" for the non-clinical tests is established by the specifications of the referenced international and national standards (ISO, ASTM, USP, AAMI/ANSI).

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not applicable. Adjudication methods are typically for evaluation of conflicting expert opinions or clinical outcomes, which is not the nature of this non-clinical submission.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No. This is a submission for a dental implant system (hardware), not an AI/software device. An MRMC study is not relevant.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    • No. This is a physical medical device. Not an algorithm.

    7. The type of ground truth used (expert concensus, pathology, outcomes data, etc)

    • For the non-clinical performance data, the "ground truth" is defined by the requirements and test methodologies of the referenced industry standards (e.g., ISO 11137 for sterilization, ISO 10993-5 for biocompatibility, AAMI/ANSI ST72 and USP <85> for pyrogenicity, SEM/EDS for material analysis). The demonstration is that the device conforms to these standards and shares equivalent characteristics with legally marketed predicate devices.

    8. The sample size for the training set

    • Not applicable. This is a physical medical device, not an AI/software device that requires a training set.

    9. How the ground truth for the training set was established

    • Not applicable, as there is no training set for this type of device.
    Ask a Question

    Ask a specific question about this device

    K Number
    K183024

    Validate with FDA (Live)

    Date Cleared
    2020-02-13

    (469 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Predicate For
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Implacil Implant System is intended for placement in the maxillary or mandibular arch to provide support for single-unit and/or multi-unit restorations. When a one-stage surgical is applied, the Implacil Implant System is intended for immediate loading when good primary stability is achieved and with appropriate occlusal loading.

    Device Description

    Implacil Implant System is composed of three implant lines that are divided according to the implant-toabutment interface: External Hex (HE), Internal Hex (HI) and Morse Taper AR Due Cone (CM AR). HE and HI lines are composed of tissue-level implants while CM AR line of bone-level implants. Each implant line is composed of implants and related prosthetic components available in multiple designs (temporary, screwed, cementable, angled, straight, UCLA, ball).

    HE implant line implants are available in two root-forms designs: conical (tapered) and cylindrical. Conical implants are available in three diameters and platforms (3.5, 4.0 and 5.0 mm) and five lengths (7.0, 9.0, 11.0, 13.0 and 15.0 mm). Cylindrical implants are provided in four diameters (3.3, 3.75, 4.0 and 4.75 mm), three platforms (3.5, 4.0 and 5.0 mm) and five lengths (8.0, 10.0, 11.5, 13.0 and 15.0 mm). HE cylindrical implants of diameters 3.75 and 4.0 share the same platform of 4.0 mm.

    HI implant line implants are available in two root-forms designs: conical (tapered) and cylindrical. Conical implants are available in three diameters and platforms (3.5, 4.0 and 5.0 mm). For diameters 3.5 and 4.0 are available in the lengths 8.0, 9.0, 11.0, 13.0 and 15.0 mm, and for diameters 5.0 are available in the lengths 7.0, 9.0, 11.0, 13.0 and 15.0 mm. Cylindrical implants are provided in four diameters (3.3, 3.75, 4.3 and 4.75 mm) and three platforms (3.5, 4.0 and 5.0 mm). For diameter 3.3 are available in the lengths 8.0, 9.0, 11.0, 13.0 and 15.0 mm, and for diameters 3.75 and 4.3 are available in the lengths 7.0, 9.0, 11.0, 13.0 and 15.0 mm. HI cylindrical implants of diameters 3.75 and 4.3 share the same platform of 4.0 mm.

    CM AR implant line implants are available in conical root-form design only, in four diameters (3.5, 4.0, 4.5 and 5.0 mm) and five lengths (7.0, 9.0, 11.0, 13.0 and 15.0 mm).

    lmplacil implants are made of commercially pure titanium (ASTM F67). Implacil prosthetic components are made of commercially pure titanium (ASTM F67) or titanium alloy (ASTM F136). Implant System screws (abutment screw, UCLA screws and coping screws) are made of titanium alloy (ASTM F136).

    The subject device abutments components mate exclusively with the subject implants of the same line (HJ, HE, CM AR).

    AI/ML Overview

    The provided document is a 510(k) Summary for a dental implant system. It outlines the device description, intended use, and a comparison to predicate and reference devices to demonstrate substantial equivalence. Crucially, this document does not contain information about acceptance criteria or a study proving the device meets specific acceptance criteria in the context of AI/ML-based medical devices.

    The "Performance Data" section explicitly states: "No clinical data were included in this submission." Instead, it lists non-clinical data for physical and material properties of the dental implants, such as sterilization validation, shelf life testing, biocompatibility, and mechanical performance (fatigue and torsional loading).

    Therefore, I cannot provide the requested information regarding acceptance criteria, study details, sample sizes, expert involvement, ground truth establishment, or MRMC comparative effectiveness studies, as these types of studies are not described in this 510(k) submission for a traditional medical device (dental implants), which are not a software device or AI/ML-based device.

    If you are looking for information on acceptance criteria and study data for AI/ML-based medical devices, you would need to consult a different type of FDA submission, specifically for software as a medical device (SaMD) or AI-enabled medical devices, where such performance data would be critical for demonstrating safety and effectiveness.

    Ask a Question

    Ask a specific question about this device

    K Number
    K182620

    Validate with FDA (Live)

    Date Cleared
    2019-01-18

    (116 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Predicate For
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    • HE (External Hex) implants, stock abutments and stock copings (originally cleared per K101207)
    • Titamax CM (Cone Morse) implants, stock abutments and stock copings (originally cleared per K101945 ● and extended per K123022, K133696 and K150199)
    • Titamax CM (Cone Morse) EX implants, stock abutments and stock copings (originally cleared per K101945 and extended per K123022, K133696 and K150199)
    • Alvim CM (Cone Morse) implants, stock abutments and stock copings (originally cleared per K101945 and ● extended per K123022, K133696 and K150199)
    • CM (Cone Morse) Drive implants, stock abutments and stock copings (originally cleared per K123022 and extended per K133696, K150182 and K150199)
    • GM (Grand Morse) Titamax implants, stock abutments and stock copings (originally cleared per K163194)
    • GM (Grand Morse) Drive implants, stock abutments and stock copings (originally cleared per K163194) ●
    • . GM (Grand Morse) Helix implants, stock abutments and stock copings (originally cleared per K163194)

    The implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading. Multiple tooth applications may be rigidly splinted.

    • Titamax WS implants, abutments and copings (originally cleared per K123022)
      The implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth to restore chewing function. The Neodent Implant System may be used for single or multiple unit restorations. Multiple tooth applications may be rigidly splinted.

    The Titamax WS implants are indicated for a delayed loading protocol.

    • Facility implants, stock abutments and stock copings (originally cleared per K123022 and extended per K133696 and K150199)
      The implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth to restore chewing function. The Neodent Implant System may be used for single or multiple unit restorations. Multiple tooth applications may be rigidly splinted.

    The Facility implants of the Neodent Implant System are indicated for replacement of maxillary lateral incisors, mandibular incisors or retention of overdentures.

    • Zygomatic implants, stock abutments and stock copings (originally cleared per K141777)
      The Zygomatic implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading. Multiple tooth applications may be rigidly splinted.

    The Zygomatic implants of the Neodent Implant System are indicated for surgical installation in the zygoma region in cases of severe jaw resorption in order to restore patient esthetics and chewing function. Zygomatic implants are recommended for the posterior (pre-molar/ molar) region, one implant on each side, with at least two standard dental implants in the anterior region to support a fixed restoration.

    • CM (Cone Morse) Titanium Base Abutment component of two-piece patient-specific abutment (originally cleared per K150367 and extended per K153624)
    • o GM (Grand Morse) Exact Titanium Base Abutment component of two-piece patient-specific abutment (originally cleared per K163194)

    The implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading. Multiple tooth applications may be rigidly splinted.

    The Titanium Base Abutment is a titanium base placed onto Neodent dental implants to provide support for customized prosthetic restorations. The Titanium Base is used with a coping and crown, or crown alone, and is indicated for cement-retained single or multi-unit restorations, or screw-retained single restorations.

    All digitally designed copings and/or crowns for use with the Neodent Titanium Base Abutment are intended to be sent to Straumann for manufacture at a validated milling center.

    • CM (Cone Morse) Titanium Base for CEREC Abutment component of two-piece patient-specific abutment (originally cleared per K160964)
      The implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading. Multiple tooth applications may be rigidly splinted.

    The Titanium Base for CEREC Abutment is a titanium base placed onto Neodent dental implants to provide support for customized prosthetic restorations. They are used with a coping and crown, or crown alone, and is indicated for cement-retained single or multi-unit restorations, or screw-retained single restorations.

    All digitally designed copings and/or crowns for use with the Neodent Titanium Base for CEREC Abutment are to be designed using Sirona inLab software or Sirona CEREC Software and manufactured using a Sirona CEREC or inLab MC X or MC XL milling unit.

    • CM Preface Abutment component of patient-specific abutment (originally cleared per K150367)
      The implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading. Multiple tooth applications may be rigidly splinted.

    The Preface Abutment is a titanium abutment to be used in fabricating a full custom abutment placed onto Neodent dental implants to provide support for customized prosthetic restorations. The Preface Abutments is indicated for screw-retained single restorations or cement-retained single or multi-unit restorations.

    All digitally designed restorations for use with the Neodent Preface Abutment are intended to be sent to Straumann for manufacture at a validated milling center.

    • GM (Grand Morse) ProPEEK Abutments (originally cleared per K163194) ●
    • CM (Cone Morse) ProPEEK Abutments (originally cleared per K170080)

    The implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading. Multiple tooth applications may be rigidly splinted.

    The Pro PEEK Abutment is indicated to be used on Neodent implants to provide temporary support for prosthesis structure for up to 6 months.

    • Neodent Implant for Orthodontic Anchor (originally cleared per K102769) ●
      The Neodent Implant for Orthodontic Anchor is a surgical device in the form of a temporary screw used as an aid in orthodontic movement procedures.

    • . The Neodent Graft Screw (originally cleared per K103084)
      The Neodent Graft Screw is an implantable device used for fixation of bone blocks for the regeneration of bone in the oral cavity. The product is intended for temporary use only.

    Device Description

    Not Found

    AI/ML Overview

    The provided text is a 510(k) Premarket Notification from the FDA regarding the MRI compatibility of various Neodent Implant System devices. It primarily focuses on defining the indications for use for different components of the implant system and does not contain information about acceptance criteria, device performance studies, sample sizes, expert qualifications, or ground truth establishment for an AI/Medical Device.

    The document is a regulatory approval letter and descriptive indications for use, not a study report or technical performance assessment. Therefore, I cannot extract the requested information from this text.

    Ask a Question

    Ask a specific question about this device

    K Number
    K170398

    Validate with FDA (Live)

    Date Cleared
    2017-11-21

    (285 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Why did this record match?
    Reference Devices :

    K120414,K072570,K072363,K092035,K101945

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    S.I.N. Dental Implant System is intended for placement in the maxillary or mandibular arch to provide support for single-unit or multi-unit restorations. When a one-stage surgical approach is applied, the S.I.N. Dental Implant System is intended for immediate loading when good primary stability is achieved and with appropriate occlusal loading. Revolution Compact with a 6 mm length is intended for delayed loading only.

    Device Description

    The subject device includes six product lines (Revolution Compact, Micro-Mini Revolution, Strong SW HE, TryOn, Strong SW HI). Five of the product lines have an external hex implant/abutment connection (HE) and one has an internal hex implant/abutment connection (HI). Each product line includes implants with an acid-etched surface and abutments in multiple designs (healing, provisional, cemented, UCLA, overdenture, conical and mini).

    Revolution implants (Revolution Compact, Micro-Mini Revolution) are cylindrical implants with apical cutting flutes and are placed with the Revolution Assembler mount. Strong SW HI are cvlindrical implants with apical cutting flutes and micro-threads on the collar. Strong SW HE has and external connection and Strong SW HI has an internal connection. TryOn implants with apical cutting flutes and a machined collar. Subject Device components are made of commercially pure titanium, titanium alloy or cobalt-chromium alloy. All subject device abutments have 0° angulation.

    AI/ML Overview

    This document is a 510(k) summary for the S.I.N. Dental Implant System. It primarily focuses on demonstrating substantial equivalence to predicate devices based on indications for use and technological characteristics, rather than presenting a performance study with acceptance criteria in the typical sense for a medical device with an AI/ML component.

    Therefore, many of the requested details about acceptance criteria, study design, and AI performance metrics are not available in this document.

    Here's an analysis based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    This document does not present acceptance criteria for a performance study in the way a clinical trial or AI validation study would. Instead, it demonstrates "substantial equivalence" of the S.I.N. Dental Implant System to existing predicate devices based on:

    • Indications for Use: The subject device's indications align with those of multiple predicate devices.
    • Technological Characteristics: Comparison of design (prosthesis attachment, restoration, implant/abutment interface, dimensions) and material composition (implant, surface, abutment, abutment screw) to predicate devices.
    • Non-clinical Testing Data: This includes validation of sterilization, biocompatibility, endotoxin testing, and shelf-life testing. These are regulatory compliance criteria, not performance metrics related to diagnostic or predictive accuracy.

    Reported Device Performance (in terms of substantial equivalence):

    Feature/TestAcceptance Criteria (Implied by Substantial Equivalence)Reported Performance (Stated Equivalence/Compliance)
    Indications for UseSimilar to predicate devices: placement in maxillary/mandibular arch for single/multi-unit restorations, immediate/delayed loading."Substantially equivalent in indications and design principles to the predicate devices." "Small differences... do not change the intended use."
    Design Characteristics (e.g., diameters, lengths, connections)Within common ranges and similar to predicate devices."Encompass the same range of physical dimensions."
    MaterialsSame or similar materials as predicate devices (e.g., CPTi Gr 4, Ti-6Al-4V, CoCr)."Made of the same or similar materials."
    SterilizationSAL of 10^-6 according to ISO 11137-1, ISO 11137-2 (radiation); SAL of 10^-6 according to ISO 17665-1 and ISO 17665-2 (steam).Validated to SAL of 10^-6 for both radiation and steam sterilization.
    BiocompatibilityAcceptable biocompatibility according to ISO 10993-1.Acceptable biocompatibility demonstrated by reference to K051859 and testing per ISO 10993-5 (cytotoxicity).
    Endotoxin TestingIn accordance with FDA Guidance documents.Limulus amebocyte lysate (LAL) endotoxin testing performed.
    Shelf-Life TestingSeal leaks according to ASTM F88/F88M, seal integrity according to ASTM F1929, accelerated age testing according to ASTM F1980.Shelf-life testing including seal leak, seal integrity, and accelerated aging reported.
    Surface Area AnalysisSubstantially equivalent to a predicate.Surface area analysis showed substantial equivalence to a predicate.

    2. Sample Size for Test Set and Data Provenance

    • Sample Size: Not applicable. This document does not describe a performance study involving a "test set" of patient data for evaluating diagnostic or predictive accuracy. The testing mentioned is for non-clinical aspects (sterilization, biocompatibility, etc.), which would involve material samples or batches.
    • Data Provenance: Not applicable in the context of patient data. The "data" refers to non-clinical testing results.

    3. Number of Experts for Ground Truth and Their Qualifications

    • Not applicable. This document pertains to the substantial equivalence of a physical dental implant system and does not involve AI/ML or a ground truth established by experts for diagnostic performance.

    4. Adjudication Method

    • Not applicable. There is no "adjudication method" described as it relates to expert consensus for a test set.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • No. This document explicitly states: "No clinical data were included in this submission." An MRMC study would fall under clinical effectiveness.

    6. Standalone (Algorithm Only) Performance Study

    • No. The device is a physical dental implant system, not a software algorithm.

    7. Type of Ground Truth Used

    • Not applicable. Not relevant for this type of device submission. The "truth" here relates to the physical and material properties meeting regulatory standards and being substantially equivalent to legally marketed devices, verified through laboratory testing and predicate comparisons.

    8. Sample Size for the Training Set

    • Not applicable. There is no "training set" as this device is not an AI/ML product.

    9. How the Ground Truth for the Training Set was Established

    • Not applicable. There is no "ground truth for a training set" as this device is not an AI/ML product.
    Ask a Question

    Ask a specific question about this device

    K Number
    K170080

    Validate with FDA (Live)

    Date Cleared
    2017-11-02

    (296 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K101945, K133510

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Pro PEEK Abutments are indicated to be used on Neodent implants to provide temporary support for prosthesis structure for up to 6 months. They can be used in one or two stage procedures and also immediate load when there is good primary stability.

    Device Description

    CM Pro PEEK abutments are temporary intermediary prosthetic components to be installed onto CM Implants to support the provisional prosthesis up to 6 months. They are composed of a customizable cylindrical body with an internal channel for the screw access and of a base for anti-rotational implant connection. The customizable portion is manufactured in PEEK (high performance polymer – specific for dental use) and the implant-to-abutment interface is made of titanium alloy. They have a coupled screw for fixing them to the Implant. They present a hexagonal indexing at the apical end of the Morse taper connection to provide anti-rotational feature to the implant-to-abutment connection, and facilitates proper alignment of the prosthesis to the implant. They are available in diameters of 4.5 and 6.0 mm and in lengths of 0.8, 1.5, 2.5, 3.5, 4.5 and 5.5 mm. The customization of the PEEK chimney must be done into the mouth of patient or chairside. Chairside customization means that the device preparation must be done in a controlled environment in the operating room, in the context of the prosthetic placement, in a surgical site's aseptic environment using sterilized tools. The dentist can wear the PEEK chimney with the aid of suitable techniques, high speed handpiece and cooling, according to the patient interocclusal space, respecting the minimum of 5mm of height. No customization is allowed for the diameter/ wall thickness of the abutment, as well as no angulation. No CAD/CAM design and fabrication is allowed for the CM Pro PEEK Abutments. Only hand-milling may be used for abutment modification. The CM Pro PEEK abutments can be used before the installation of the final prosthesis to maintain, stabilize and shape the soft tissue (gum) during the healing phase.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and the study information based on the provided text, formatted as requested:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance CriteriaReported Device Performance
    BiocompatibilityNo extracts of leachable substances of concern were identified. No cytotoxicity response was observed. (Assessed according to ISO 10993-1, ISO 10993-5, ISO 10993-18)
    Mechanical Strength (Dynamic Fatigue)Strength demonstrated through fatigue testing. (Performed according to ISO 14801 and FDA Guidance for Industry and FDA Staff - Class II Special Controls Guidance Document: Root-form Endosseous Dental Implants and Endosseous Dental Abutments)
    Sterilization Assurance Level (SAL)SAL of 10⁻⁶ achieved. (Validated by bioburden method, according to ISO 11135)
    Ethylene Oxide (EO) Sterilization ResidualsLess than the maximum allowable limits. (Verified according to ISO 10993-7)
    Sterile Barrier Shelf Life2 years. (Determined through real-time and accelerated aging protocol, according to ASTM F1980. Tested for sterility, thermal seal integrity, and tensile strength of thermal seal according to ISO 11737, US Pharmacopeia, ASTM E499/E499M, ASTM F1929, and ASTM F88/F88M)

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not explicitly state the sample size for the "test set" in terms of number of devices for biocompatibility, mechanical, or sterilization testing. It mentions "samples" were submitted for testing.

    The data provenance is from laboratory testing performed by or for JJGC Indústria e Comércio de Materiais Dentários SA, a company based in Curitiba, Parana, BRAZIL. The clinical data was not submitted or relied upon, so the testing is likely retrospective in the sense that it's laboratory data, not data gathered from human trials.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications of Experts

    This information is not applicable as the studies conducted are laboratory-based performance tests (biocompatibility, mechanical, sterilization validation) and do not involve human interpretation or subjective assessment that would require expert ground truth establishment in the way it's typically understood for AI/diagnostic devices. The acceptance criteria are based on established international standards (ISO, ASTM) and FDA guidance documents.

    4. Adjudication Method for the Test Set

    This is not applicable for the type of laboratory performance studies described. Adjudication methods (like 2+1, 3+1) are typically used in studies involving human interpretation of medical images or clinical outcomes, which did not occur here.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No, an MRMC comparative effectiveness study was not done. The study involved laboratory performance testing of the device itself, not a comparison of human readers with or without AI assistance.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Study Was Done

    No, a standalone algorithm performance study was not done. This submission is for a physical medical device (dental abutment), not a software algorithm.

    7. The Type of Ground Truth Used

    The "ground truth" for the performance tests consists of:

    • Compliance with international standards: ISO 10993 series for biocompatibility, ISO 14801 and FDA Guidance for Mechanical Strength, ISO 11135 and ISO 10993-7 for Sterilization, and ASTM F1980, ISO 11737, US Pharmacopeia, ASTM E499/E499M, ASTM F1929, and ASTM F88/F88M for Shelf Life.
    • Predicate device characteristics: The subject device's performance is compared against the established performance and characteristics of legally marketed predicate devices to demonstrate substantial equivalence.

    8. The Sample Size for the Training Set

    This information is not applicable. The device is a physical dental abutment, not an AI model that requires a training set.

    9. How the Ground Truth for the Training Set Was Established

    This information is not applicable as there is no training set for a physical device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K160786

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2016-11-21

    (244 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Predicate For
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Rodo Abutment System is intended to be used in conjunction with compatible implant systems in the maxillary or mandibular arch to provide support for crowns, bridges or overdentures.

    Device Description

    The Rodo Abutment System includes the Rodo Abutment, Smileloc Sleeve, Silicone Seal, Titanium Coping, Temporary Cap, abutment screws, and Smileloc Activator (or Smileloc Remover). The Smileloc Sleeve is used to lock and unlock the Titanium Coping for final restoration to or from the abutment. This makes the prosthesis removable.

    Rodo Abutment is provided in five series designs (100 F. 200 P. 300 S. 400 M. 500 D) with the 200 P and 500 D series having angled abutments (17°, 30°), for a total of nine designs. The 200 P and 500 D series are designed for multi-unit restorations only, the 300 S series is designed for limited occlusal space, and the 400 M series is designed for large interproximal spaces. Abutments are available in sizes ranging from 0 3.0 mm depending on the compatible implant system in use. Designs are available with engaging and non-engaging implant-abutment interfaces.

    AI/ML Overview

    The provided document is a 510(k) summary for the Rodo Abutment System, a dental device. It outlines the device's indications for use, its classification, and a comparison to predicate devices, but does not contain information about acceptance criteria or a study designed to prove the device meets specific performance criteria in terms of algorithm-based metrics (like sensitivity, specificity, or AUC) as would be typical for an AI/ML device.

    The closest information available that might relate to "acceptance criteria" for a medical device (not specifically an AI/ML device) typically involves demonstrating substantial equivalence to a legally marketed predicate device through various tests and comparisons.

    Here's an analysis based on the provided document, addressing the requested points:

    1. Table of Acceptance Criteria and Reported Device Performance

    As this is a 510(k) submission for a physical dental abutment system and not an AI/ML device, there are no specific performance metrics like sensitivity, specificity, or accuracy mentioned as "acceptance criteria" for an algorithm. Instead, the "performance" is demonstrated through various non-clinical and clinical tests to show safety and effectiveness and substantial equivalence to predicate devices.

    Acceptance Criteria (Implied by Substantial Equivalence and Testing)Reported Device Performance (from "Performance Data" & "Clinical Data" sections)
    Sterility (SAL 10⁻⁶)Validated according to ISO 17665-1 and ISO 17665-2, demonstrating a sterility assurance level (SAL) of 10⁻⁶.
    Biocompatibility (Cytotoxicity, Sensitization, Irritation)Tested according to ISO 10993-5 (cytotoxicity) and ISO 10993-10 (sensitization and irritation), demonstrating acceptable biocompatibility.
    Electrical Safety (if applicable - though less relevant for an abutment)Electrical safety analysis according to AAMI / ANSI ES60601-1:2005/(R) 2012 and related IEC standards, demonstrating acceptable electrical safety (though the relevance for a non-powered dental abutment is minimal, it was part of the submission).
    Thermal PropertiesTested according to ASTM F2004, showing acceptable transition temperatures.
    Corrosion ResistanceTested according to ASTM G71 and ASTM F2129, and nickel leaching evaluation, showing acceptable corrosion resistance.
    Retention StrengthRetention testing, showing acceptable retention strength.
    Compatibility with OEM ImplantsReverse engineering and dimensional analysis of OEM devices, showing that the Rodo Abutment is compatible with corresponding OEM implants.
    Mechanical Performance / Dynamic Compression-BendingDynamic compression-bending testing according to ISO 14801, showing mechanical performance sufficient for its intended use.
    Clinical Safety & Effectiveness (for intended use)A prospective multi-center clinical trial demonstrating safety and effectiveness. Overall conclusion: "Rodo Abutment System provides an appropriate method of attaching prosthetic restorations to dental implant abutments. If necessary, it allows repeated removal of the restoration, as is the case for screw-retained restorations on dental implant abutments."
    Substantial Equivalence in Indications for Use"The subject device is substantially equivalent in indications and design principles to the predicate devices shown above." Minor differences in Indications for Use language between the systems do not change the intended use.
    Substantial Equivalence in Design/TechnologySimilar technological characteristics, similar materials, similar range of physical dimensions (diameter, gingival height, angle), similar packaging and sterilization methods compared to predicate devices.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size (Clinical Trial): 34 subjects were enrolled, 32 subjects received Rodo Abutments and restorations. Out of these, 3 subjects received 4 abutments each as part of full arch treatment, resulting in a total of 41 Rodo Abutments placed and restored.
    • Data Provenance: The document states, "A prospective multi-center clinical trial... was conducted under an Investigational Device Exemption study according to FDA guidelines." This indicates it's prospective data. The document does not explicitly state the country of origin, but given the FDA submission context, it's presumed to be a US-based study or at least data acceptable for US regulatory purposes.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    This information is not provided in the document. For a physical device like a dental abutment, "ground truth" might refer to clinical outcomes assessed by trained dental professionals, but the study description does not detail the number or qualifications of experts involved in assessing device performance or generating the "ground truth" of safety and effectiveness outcomes beyond the medical staff conducting the trial.

    4. Adjudication Method for the Test Set

    This information is not provided in the document. Adjudication methods (like 2+1 or 3+1) are typically relevant for studies where multiple readers interpret data and discrepancies need to be resolved, which is common in imaging studies for AI/ML devices. For a clinical trial of a physical implant, such a method for "test set" adjudication is not typically described in this manner.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and the Effect Size

    No, an MRMC comparative effectiveness study was not done. This type of study is specific to evaluating diagnostic performance, often of AI/ML systems or diagnostic tests, comparing multiple readers' interpretations of cases. The Rodo Abutment System is a physical dental device.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    No, a standalone algorithm performance study was not done. The Rodo Abutment System is a physical dental device, not an algorithm or AI system.

    7. The Type of Ground Truth Used

    For the clinical study, the "ground truth" for evaluating the Rodo Abutment System's safety and effectiveness was based on clinical outcomes data from human subjects who received the device. This included:

    • Observation of adverse events (e.g., abutment screw loosening, crown separation, non-device related events).
    • The overall clinical assessment that the system "provides an appropriate method of attaching prosthetic restorations to dental implant abutments" and "if necessary, it allows repeated removal of the restoration."

    For non-clinical tests, the "ground truth" was based on engineering standards and direct measurement/testing results (e.g., SAL for sterility, acceptable ranges for biocompatibility, mechanical strength, corrosion resistance).

    8. The Sample Size for the Training Set

    This product is a physical medical device, not an AI/ML algorithm. Therefore, there is no "training set" in the context of machine learning. The clinical and non-clinical data collected serve as validation for the device's design and manufacturing rather than training an algorithm.

    9. How the Ground Truth for the Training Set Was Established

    As there is no training set for an AI/ML algorithm, this question is not applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    K150367

    Validate with FDA (Live)

    Date Cleared
    2015-07-13

    (151 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K133421, K133592, K123022, K101945

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Titanium Base Abutment is a titanium base placed onto Neodent dental implants to provide support for customized prosthetic restorations. It is used with a coping and crown, or crown alone, and is indicated for cement-retained single or multi-unit restorations, or screw-retained single restorations.

    PreFace Abutment is a titanium abutment to be used in fabricating a full custom abutment and placed onto Neodent dental implants to provide support for customized prosthetic restorations. PreFace Abutments are indicated for screw-retained single restorations or cement-retained single or multi-unit restorations.

    Device Description

    The purpose of this submission is to expand the Neodent Implant System components cleared under K101945, K123022, and K133592; these submissions included dental implants with a Morse taper abutment interface, mating abutments, abutment screws, and other associated components. This submission includes the Titanium Base Abutment, provided in two prosthetic platform diameters (3.5 and 4.5 mm), each in five gingival heights (0.8, 1.5, 2.5, 3.5 and 4.5 mm). Titanium Base is an abutment to be used as a base when fabricating a zirconia superstructure. This submission also includes the PreFace Abutment in two overall (milling) diameters of 11.5 and 15.8 mm. The PreFace Abutment with overall (milling) diameter of 15.8 mm is only used to mill an angled abutment.

    PreFace is an abutment to be used in fabricating a full custom abutment in titanium alloy. After milling the minimum wall thickness for the PreFace must be no less than 0.4 mm, and the emergence profile diameter must be at least 3.3 mm. The maximum limit for angulation is 30°, and the maximum gingival height is 6 mm from the implant platform. In the case of an angled abutment, the cementable height from the emergence profile (prosthetic height) must not exceed 6 mm. The total height of the abutment (above the implant-abutment connection platform) must be no greater than 14.2 mm and no shorter than 4 mm. The range for the abutment body diameter (above the implant-abutment connection platform) is 3.3 mm. The implant interface must remain intact and cannot be modified.

    The subject abutments are made of titanium alloy conforming to ASTM F136 Standard Specification for Wrought Titanium-6Aluminum-4Vanadium ELI (Extra Low Interstitial) Alloy for Surgical Implant Applications (UNS R56401). The subject abutments are compatible with Neodent dental implants having the Morse taper interface cleared in K101945, K123022 and K133592.

    AI/ML Overview

    The provided text is a 510(k) Summary for the Neodent Implant System. It describes a medical device approval and focuses on demonstrating substantial equivalence to existing predicate devices rather than proving the device meets specific acceptance criteria through a standalone study with defined performance metrics, ground truth, or expert consensus.

    Therefore, many of the requested elements regarding acceptance criteria, study design, expert qualifications, and ground truth are not present in this type of regulatory document.

    However, I can extract information related to performance data and comparison to predicate devices, which serve as a form of "acceptance criteria" in the context of substantial equivalence.

    Here's an attempt to answer your request based on the provided document:

    1. A table of acceptance criteria and the reported device performance

    In the context of a 510(k) submission, "acceptance criteria" are typically demonstrating substantial equivalence to legally marketed predicate devices through comparison of technological characteristics and performance data. The reported "performance" is that the new device is at least as good as, or substantially equivalent to, the predicates.

    Acceptance Criteria (Demonstration of Substantial Equivalence)Reported Device Performance
    Intended Use EquivalenceThe subject device and the primary predicate devices have substantially equivalent indications for use, including providing support for customized prosthetic restorations.
    Design and Function Equivalence (Titanium Base Abutment)The subject Titanium Base abutments are substantially equivalent in design, function, size, and material to the Straumann CARES Variobase Abutments (K120822). They are both titanium alloy bonding bases for CAD/CAM zirconia superstructures.
    Design and Function Equivalence (PreFace Abutment)The subject PreFace abutments are substantially equivalent in design, function, size, and material to the Straumann C.A.R.E.S. Titanium Abutment (K052272). Both are abutment blanks for CAD/CAM fabrication of a custom titanium alloy abutment. Each has a precision implant-abutment interface compatible with specific implant systems.
    Material EquivalenceThe subject device uses Ti-6Al-4V, while predicate devices use Ti-6Al-7Nb. This is considered a "minor difference" but is justified by mechanical testing.
    Mechanical Strength (Fatigue Testing)Mechanical test results demonstrated that the strengths of subject Titanium Base and PreFace abutments are equal to or greater than that of predicate abutments in K120822 and K133421, respectively. (Performance: Fatigue testing according to ISO 14801).
    BiocompatibilityNon-clinical data submitted, referenced, or relied upon to demonstrate substantial equivalence include biocompatibility. (Performance/Finding: Biocompatible, assumed to meet relevant standards).
    SterilizationSterilization testing was performed according to ISO 17665-1 and ISO 17665-2. (Performance/Finding: Sterilizable using moist heat, assumed to meet standards, and packaging similar to predicates). The device is "to be sterilized using the same processes" as predicate devices.
    Operating PrincipleThe device uses the same operating principle as predicate devices.
    Basic DesignThe device incorporates the same basic design as predicate devices.
    PackagingThe device has similar packaging to predicate devices.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample Size for Test Set: Not specified in the document. The performance data mentioned are "non-clinical" (biocompatibility, engineering analysis, dimensional analysis, mechanical testing, sterilization testing). For mechanical testing (ISO 14801), sample sizes are not detailed, but such standards typically require a specific number of samples for statistically valid testing.
    • Data Provenance: The document does not specify the country of origin of the data. It is a premarket notification from a Brazilian manufacturer (JJGC Indústria e Comércio de Materiais Dentários SA) to the U.S. FDA, meaning the testing data would typically be generated by or for the manufacturer. The data is non-clinical, likely from laboratory testing. It is not clinical data (no "retrospective or prospective" clinical studies are mentioned).

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • This information is not applicable and not provided in the document. The document describes a medical device (dental implant abutments) that undergoes non-clinical engineering and material testing, not diagnostic performance evaluation requiring ground truth established by experts.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • This information is not applicable and not provided in the document. Adjudication methods are typically used in clinical studies or performance evaluations where there's subjectivity and disagreement among reviewers (e.g., in imaging interpretation). The tests described are objective, non-clinical tests (e.g., mechanical fatigue, sterilization parameters).

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No, a multi-reader multi-case (MRMC) comparative effectiveness study was not done. This type of study is relevant for AI/imaging devices that assist human interpretation, which is not the nature of the dental implant abutments described.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • No, a standalone (algorithm only) performance study was not done. This is not an AI/algorithm-based device. The "performance data" refers to the physical and material properties of the abutments.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • This information is not applicable and not provided in the document as it pertains to non-clinical engineering and material testing. The "ground truth" for mechanical testing, for example, would be the physical measurement of failure points or fatigue limits compared against a standard. For biocompatibility, it's compliance with ISO standards.

    8. The sample size for the training set

    • This information is not applicable and not provided in the document. There is no AI or algorithm involved that would require a "training set."

    9. How the ground truth for the training set was established

    • This information is not applicable and not provided in the document as there is no training set mentioned.
    Ask a Question

    Ask a specific question about this device

    Page 1 of 2