Search Filters

Search Results

Found 2 results

510(k) Data Aggregation

    K Number
    K253253

    Validate with FDA (Live)

    Device Name
    IPDmilled Blanks
    Date Cleared
    2026-01-22

    (115 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    IPDmilled Blanks are intended to be used in conjunction with endosseous dental implants in the maxillary or mandibular arch to provide support for prosthetic restorations.

    All digitally designed CAD/CAM customizations for the IPDmilled Blanks are to be designed and manufactured according to digital dentistry workflow or to be sent to an IPD validated milling center for manufacture. The workflow system integrates multiple components of the digital dentistry workflow: scan files from intra-oral and lab (desktop) scanners, CAD software, CAM software, milling machine and associated tooling and accessories. Compatible Implant Systems: Dentium Co., Ltd Implantium, Friadent Implant Systems, Neoss ProActive Implant, SPI® Dental Implant, Inicell®, BEGO Semados® S-Line, ANKYLOS® C/X Implant System, MIS V3 Conical Connection Dental Implant System, Conical Connection Implants (MIS® C1), MIS C1 Narrow Platform Conical Connection Implant System, MIS C1 Wide Platform Conical Connection Abutments, PRAMA White Implant Systems, Altatec GmbH CAMLOG®/CONELOG® PROGRESSIVE-LINE Implants, Straumann TLX Implant System, Kontact Dental Implant System, ICX-Implant System, Tapered Pro Conical Implant System, Straumann® Tissue Level, Zimmer Tapered Screw-Vent®, Nobel Biocare® Nobel Active®, Straumann® Bone Level Tapered Implants, Neodent Implant System – GM Line, Osstem Implant System, Xpeed AnyRidge Internal Implant System, 3i Osseotite® Certain® Dental Implants, Astra Tech Implant System (Osseospeed®), OsseoSpeed™ Plus, BioHorizons Tapered Internal Implant System, MIS Internal Hex Dental Implant System (MIS® Seven®), Straumann BLX Ø3.5 mm Implants, Straumann® BLX Implant System, ALTATEC Camlog Screwline Implant System, Replace TiUnite Endosseous Implant.

    Device Description

    The purpose of this submission is to expand abutment categories of IPD Dental Implant Abutments, which were previously cleared.

    IPDmilled Blanks is a dental implant abutment system composed of dental abutments and screws intended to be placed into dental implants to provide support for dental prosthetic restorations. Abutments provide basis for single or multiple tooth prosthetic restorations. They are available in a variety of connection types to enable compatibility with commercially available dental implants systems. IPDmilled Blanks have a pre-manufactured connection interface that fits directly with a pre-specified dental implant. The customized shape of the abutment is intended to be designed and manufactured according to a digital dentistry workflow or to be sent to an IPD validated milling center for manufacture. IPDmilled Blank is delivered non-sterile and the final restoration, including the screw, is intended to be sterilized at the dental clinic before it is placed in the patient.

    The IPDmilled Blanks are blistered together with their specific screw. The screws are intended to attach the prosthesis to the dental implant.

    The metallic components of the subject abutments and screws are made of titanium alloy conforming to ISO 5832-3 "Implants for surgery – Metallic materials – Part 3: Wrought titanium 6-aluminium 4-vanadium alloy".

    The design and manufacturing of the custom abutment will be conducted using a digital dentistry workflow requiring the use of the following equipment and software:
    Intraoral Scanner: 3Shape TRIOS A/S Series
    Desktop Scanner: 3Shape E Series.
    Design Software: 3Shape Abutment Designer Software, K151455.
    AbutmentCAD, K193352.
    Milling unit: CORiTEC 350i PRO / CORiTEC 350i Loader PRO with MillBox CAM software.

    IPDmilled Blank libraries' have built-in design limitations, and the user isn't allowed to exceed these limitations. The custom abutment design limitation specifications are as follows:
    Minimum gingival height: 0.5 mm
    Maximum gingival height: 6.0 mm
    Minimum wall thickness: 0.4 mm
    Minimum post height: 4.0 mm

    All IPDmilled Blanks are for straight abutments only.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K201700

    Validate with FDA (Live)

    Date Cleared
    2021-01-13

    (205 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K090716, K161435, K102436, K161416, K072878

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The BEGO Semados® RS/RSX implant is indicated for single or multiple unit restorations on splinted or non-splinted applications both in the upper and lower jaw. This can be achieved by a 2-stage or 1-stage surgical technique in combination with immediate, early or delayed loading on sufficient primary stability and appropriate occlusal loading.

    The BEGO Semados® RS/RSX implant 3.0 is only indicated for single unit restorations of the lower lateral, central incisors or upper lateral incisors.

    The healing posts are indicated for patients treated with BEGO Semados® RS/RSX implants for the time during healing of the surrounding soft tissue.

    The abutments are indicated for patients treated with BEGO Semados® RS/RSX implants as an aid in prosthetic rehabilitation.

    PS ITA, PS TTiA and PS TTiA NH are intended to be used for a maximum period of 6 months.

    Device Description

    The BEGO Semados® RS/RSX Implant System consists of implants, healing posts and abutments.

    BEGO Semados® RS/RSX implants are self-tapping, conical endosseous dental implants made of commercially pure titanium Grade 4. In contrast to the RSX implant family, the RS implant family has a 0.5 mm machined neck region. BEGO Semados® RS/RSX implants are marketed together with cover screws and insertion posts.

    The healing posts are sterile packaged Titanium Grade 5 dental healing abutments that are available in two different sizes. Healing posts can be used either to shape the soft tissue after sub-merged healing of an implant (two-stage) or to keep the shape of the soft tissue after having placed the implant (one-stage).

    The abutments are prefabricated prosthetic components made of Titanium Grade 5 directly connected to BEGO Semados® implants with Platform Switch design such as BEGO Semados® RS/RSX implants. They are delivered non-sterile but have to be sterilized by the end-user. They serve as an aid in temporary (provisional) and permanent prosthetic rehabilitation. The abutments are used for single or multiple tooth restorations. There are two types of abutments regarding the duration of use: provisional abutments intended for a limited period of ≤ six months and permanent abutments. The abutments are marketed with the compatible prosthesis and a technician screw.

    The MultiPlus system consists of the PS MultiPlus abutments, the MultiPlus Titanium abutment, the MultiPlus Healing posts, the MULTI PLUS UNIVERSAL component and various supporting tools. The MultiPlus system is intended for occlusal screw-retained bridge, full dentures and bar constructions in the mandible and maxilla.

    The Easy-Con system consists of the PS Easy-Con abutment and the Easy-Con laboratory set. The Easy-Con system is used to retain full supported dentures in the mandible or maxilla on two to four implants.

    AI/ML Overview

    The provided document is a 510(k) Premarket Notification for the BEGO Semados® RS/RSX Implant System. This type of submission focuses on demonstrating substantial equivalence to a legally marketed predicate device, rather than proving the safety and effectiveness of a novel device through extensive clinical trials with pre-defined acceptance criteria.

    Therefore, the document does not contain the kind of information requested in your prompt (e.g., acceptance criteria for an AI/ML model's performance, sample sizes for test sets, expert ground truth establishment, MRMC studies, or training set details). The "performance data" section (Section 11) refers to non-clinical testing of the physical implant system, such as biocompatibility, mechanical properties (fatigue, corrosion), and sterilization, typical for traditional medical devices. Section 12 explicitly states that "no human clinical testing was required."

    This submission is about demonstrating that a new dental implant system is as safe and effective as existing, legally marketed implant systems, based on similar technology, materials, and non-clinical performance characteristics. It is not an AI/ML device submission.

    Thus, I cannot extract the requested information as it is not present in the provided text.

    Ask a Question