Search Filters

Search Results

Found 7 results

510(k) Data Aggregation

    K Number
    K241127

    Validate with FDA (Live)

    Date Cleared
    2024-12-27

    (248 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K210161, K200827, K201323, K132242, K083067

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The INNO SLA Mini Plus® Implant System is divided into two types:

    • Cemented Type
      The Cement type is indicated for use in the treatment of missing maxillary lateral incisors or the mandbular central and lateral incisors to serve as temporary support prosthetic devices during stage of permanent endosseous dental implant, such as artificial teeth, in order to restore masticating function in partially edentulous patients.

    • Ball Type
      The Ball type is designed for use in dental implant surgery. The Ball type is intended for use in partially or fully edentulous mandibles and maxillae, in support of overdentures. The use of the Ball type implants is not to exeed one hundred and eighty (180) days.

    The Cemented Type and Ball Type implant bodies are indicated for immediate loading when good primary stability is achieved and with appropriate occlusal loading.

    Device Description

    The INNO SLA Mini Plus® Implant System has two types, cement type and ball type. The INNO SLA Mini Plus® Implant System is a one-piece endosseous dental implant which is a combination of implant and abutment sections. The implant is made of commercially pure titanium and has S.L.A. surface treatment.

    AI/ML Overview

    The provided text is a 510(k) summary for the INNO SLA Mini Plus® Implant System, which establishes substantial equivalence to predicate devices rather than proving a device meets specific acceptance criteria based on a clinical study for performance. Therefore, much of the requested information regarding acceptance criteria, study details, and expert involvement is not present in the provided document.

    However, I can extract the non-clinical performance data and related information as presented.

    Here's a breakdown of the available information:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not present a table of acceptance criteria with corresponding device performance metrics from a formal study. Instead, it describes various non-clinical tests conducted or leveraged to demonstrate substantial equivalence to predicate devices. These tests primarily focus on material properties, manufacturing processes, and safety aspects.

    Acceptance Criteria (Implied)Reported Device Performance / Assessment
    BiocompatibilityLeveraged K201323; Biocompatibility tests performed and results support substantial equivalence.
    Shelf LifeLeveraged K132242.
    Sterilization ValidationLeveraged K201323. Sterilization validation test conducted for POM caps & Nylon caps per ISO 17665-1 and ISO 17665-2.
    Endotoxin LimitEndotoxin testing to be conducted on random batch every two months using Limulus amebocyte lysate (LAL) test (gel-clot technique).
    Fatigue TestingNot required as no angled abutments in the submission.
    MRI SafetyNon-clinical worst-case MRI review conducted. Scientific literature (Kim et al., Woods et al.) and ASTM standards (F2052, F2213, F2182, F2119) referenced to confirm stability of CP Ti Gr.4 in MRI environment and address FDA guidance.
    Material (CP Ti Gr.4)Confirmed stability in MRI environment.
    Material (POM caps, Nylon caps)Sterilization validation achieved.
    Manufacturing (SLA surface treatment)Leveraged K132242.

    2. Sample Size Used for the Test Set and Data Provenance

    This information is not provided in the document. The document describes non-clinical tests, and for those, the "sample size" would refer to the number of units tested. This detail is not present. Data provenance (country of origin, retrospective/prospective) is also not applicable or not disclosed for these non-clinical tests.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of those Experts

    This information is not provided. This document focuses on demonstrating substantial equivalence to existing devices through non-clinical testing and comparison of characteristics, not through a clinical study requiring expert-established ground truth.

    4. Adjudication Method for the Test Set

    This information is not provided. Adjudication methods are typically relevant for clinical studies involving multiple readers or assessors, which is not described here.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This information is not provided. The device is an endosseous dental implant system, not an AI-assisted diagnostic tool. Therefore, an MRMC comparative effectiveness study involving AI assistance would not be applicable.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This information is not applicable. The device is a physical dental implant system, not an algorithm or AI.

    7. The Type of Ground Truth Used

    For the non-clinical tests described:

    • Biocompatibility/Chemical Analysis: The ground truth would be established by industry standards and regulatory requirements for safe material interaction with biological systems.
    • Sterilization Validation: Ground truth is established by meeting the sterility assurance level (SAL) defined by ISO standards.
    • Shelf Life: Ground truth is established by assessing material degradation over time under specific conditions.
    • Endotoxin Testing: Ground truth is established by meeting specified pyrogen limits.
    • MRI Safety: Ground truth is established by referenced scientific literature and adherence to ASTM standards and FDA guidance for MR safety, which define acceptable parameters for magnetic field interaction, heating, and artifact generation.

    8. The Sample Size for the Training Set

    This information is not applicable/not provided. There is no mention of a "training set" as this is not an AI/machine learning device. The non-clinical tests would have involved a sample size of the physical device components, but these details are not disclosed.

    9. How the Ground Truth for the Training Set Was Established

    This information is not applicable/not provided for the same reason as point 8.

    Ask a Question

    Ask a specific question about this device

    K Number
    K241972

    Validate with FDA (Live)

    Date Cleared
    2024-12-27

    (175 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The BLUEDIAMOND IMPLANT is intended to be surgically placed in the maxillary or mandibular molar areas for the purpose providing prosthetic support for dental restorations (Crown, bridges, and overdentures) in partially or fully edentulous individuals. It is used to restore a patient's chewing function in the following situations and with the clinical protocols:

    • Delaved loading
    • Immediate loading when good primary stability is achieved and with appropriate occlusal loading.
      For the BLUEDIAMOND IMPLANTS with a Thread Length of 5mm,
      It is indicated for fixed or removable reconstruction in situations of moderate to severely atrophic jawbone and with adequate bone quality that allows primary stability after implant insertion, where a longer implant cannot be placed due to limited vertical bone height. The recommended healing time before loading is between 10 to 12 weeks.
      It is specifically recommended for:
    • Fixed partial dentures/splinted units (one implant per unit)
    • Pontic cases in combination with at least one longer implant
    • Fully edentulous cases with at least one 5 mm Short Implant in combination with 2 longer implants in the anterior region and at least four total implants
    Device Description

    The BLUEDIAMOND IMPLANT is a dental implant body system made of CP Ti Grade 4 with the surface treated by SLA method. It is intended to be placed in the maxillary or mandibular areas to restore masticatory function.
    It has different thread lengths depending on the diameter and length. The Implanted length of the device is the length that is implanted into the bone, including the length from the thread to the shoulder, which is the non-threaded part.
    The Gingival (Cuff) area of the device has grooves; the bottom of the grooves indicate the implantable length.
    The BLUEDIAMOND IMPLANT is consisted of the following components.
    BLUEDIAMOND IMPLANT Cuff Type: The BLUEDIAMOND IMPLANT is a dental implant body system made of CP Ti Grade 4 with the surface treated by SLA method. It is intended to be placed in the maxillary or mandibular areas to restore masticatory function.
    Material: CP Ti Grade 4 of ASTM F67
    Dimension (mm):

    • Normal Thread Ø 4.0 x 9.0, 11.0, 13.0, 15.0 (7.0, 9.0); Ø 4.4 x 7.0, 9.0, 11.0, 13.0, 15.0 (5.0, 7.0, 9.0); Ø 4.7 x 7.0, 9.0, 11.0, 13.0, 15.0 (5.0, 7.0, 9.0)
    • Deep Thread Ø 4.4 x 9.0, 11.0, 13.0, 15.0 (5.0, 7.0, 9.0); Ø 4.8 x 7.0, 9.0, 11.0, 13.0, 15.0 (5.0, 7.0, 9.0); Ø 5.1 x 7.0, 9.0, 11.0, 13.0, 15.0 (5.0, 7.0, 9.0)
      Diameter X Total Length (Thread Length):
    • Normal Thread Ø 4.0: 8.0, 9.0, 10.0, 11.0 (1.0, 2.0); Ø 4.4: 7.0, 8.0, 9.0, 10.0, 11.0 (1.0, 2.0); Ø 4.7: 7.0, 8.0, 9.0, 10.0, 11.0 (1.0, 2.0)
    • Deep Thread Ø 4.4: 8.0, 9.0, 10.0, 11.0 (1.0, 2.0); Ø 4.8: 7.0, 8.0, 9.0, 10.0, 11.0 (1.0, 2.0); Ø 5.1: 7.0, 8.0, 9.0, 10.0, 11.0 (1.0, 2.0)
      Implanted Length (Thread to Shoulder Height): 2.0, 3.0, 4.0
      Gingival (Cuff) Height: Not Found

    The BLUEDIAMOND IMPLANTs are compatible to abutments of The BLUEDIAMOND IMPLANT System from K182448, K192614, K210161, K203808, K233450.

    AI/ML Overview

    The provided text is an FDA 510(k) summary for a dental implant device (BLUEDIAMOND IMPLANT). It focuses on demonstrating substantial equivalence to predicate devices, rather than an AI/ML medical device. Therefore, it does NOT contain the specific information required to answer your prompt, such as:

    • Acceptance Criteria for AI/ML Performance: The document does not describe performance metrics like sensitivity, specificity, AUC, or other measures typically used for AI/ML models. Instead, it focuses on physical and material properties, and mechanical performance (fatigue, pull-out).
    • Study Proving Device Meets Acceptance Criteria for AI/ML: No AI model training, validation, or testing is described. The "performance test" section refers to fatigue tests and pull-out tests, which are engineering tests for the physical implant, not for an AI algorithm.
    • Sample Sizes for Test Set (AI/ML): Not applicable, as there's no AI/ML test set.
    • Data Provenance (AI/ML): Not applicable.
    • Number of Experts/Qualifications (AI/ML Ground Truth): Not applicable.
    • Adjudication Method (AI/ML Ground Truth): Not applicable.
    • MRMC Study (AI/ML): Not applicable.
    • Standalone Performance (AI/ML): Not applicable.
    • Type of Ground Truth (AI/ML): Not applicable.
    • Sample Size for Training Set (AI/ML): Not applicable.
    • How Ground Truth for Training Set was Established (AI/ML): Not applicable.

    The document primarily discusses:

    • Device Description: Material (CP Ti Grade 4), surface treatment (S.L.A), dimensions, components.
    • Indications for Use: Placement in maxillary/mandibular molar areas for prosthetic support, delayed and immediate loading protocols, specific recommendations for 5mm thread length implants.
    • Substantial Equivalence: Comparison of the BLUEDIAMOND IMPLANT to a primary predicate device (ARi ExCon Implant System) and several reference devices based on design, dimensions, material, surface treatment, sterilization, shelf life, and features.
    • Non-Clinical Testing: Biocompatibility, pyrogen/endotoxin testing, sterilization validation, shelf life, modified surface treatment evaluation, and performance test (fatigue test in accordance with ISO 14801, and pull-out testing), and MR compatibility.

    In summary, the provided text describes a physical dental implant device and its regulatory submission to the FDA, not an AI/ML-driven medical device. Therefore, it does not contain the information requested about AI acceptance criteria, performance studies, or ground truth establishment.

    Ask a Question

    Ask a specific question about this device

    K Number
    K234142

    Validate with FDA (Live)

    Date Cleared
    2024-09-18

    (264 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The TiGEN Abutment, PMMA Abutment and Scan Healing Abutment are intended for use on endosseous dental implants in the edentulous or partially edentulous maxilla or mandible, as an aid in prosthetic rehabilitation.

    The PMMA Abutment is indicated to be used pror to the final components to maintain, stabilize and shape the soft tissue during the healing plase. They must be placed out of occlusion and are for temporary use (3 months).

    For TiGEN Abutment and PMMA Abutment, all digitally designed abutments for use with PMMA Abutment and TiGEN Abutment are intended to be sent to a MegaGen-validated milling center for manufacture.

    Device Description

    The TiGEN Abutment is machined with the final prosthetic in accordance with the intraoral structure. It is machined by using dental CAD/CAM technology in accordance with customized patient's information in MegaGen-validated milling center. The TiGEN Abutment is made of Ti-6Al-4V ELI alloy. And It is provided with abutment screw. All TiGEN Abutment is provided non-sterile. The milled TiGEN Abutment must be sterilized by users prior to use.

    The PMMA Abutment is a temporary prosthesis used until the final prosthesis is placed for up to three months. The PMMA Post is machined with the temporary prosthetic in accordance with the intraoral structure by using dental CAD/CAM technology. The PMMA Cuff is made of Ti-6Al-4V ELI alloy and available in various gingival heights. The PMMA Post is made of Polymethyl methacrylate and available in various diameters and lengths so that it can be used according to individual patient conditions. All PMMA Abutment is provided non-sterile with abutment screw. The milled PMMA Abutment must be sterilized by users prior to use.

    The Scan Healing Abutment designed to aid in soft tissue contouring during the healing period after implant placement, creating an emergence profile for the final prosthesis. And they have the added design feature to be scannable an intraoral impression by digital scanner. The Scan Healing Abutment is provided with abutment screw and is provided gamma-sterile.

    AI/ML Overview

    This document pertains to a 510(k) premarket notification for dental implant abutments and does not contain information about an AI/ML medical device. Therefore, a table of acceptance criteria and a study proving the device meets the criteria, as requested by the prompt, cannot be extracted from the provided text for an AI/ML context.

    The document discusses the substantial equivalence of the "TiGEN Abutment, PMMA Abutment and Scan Healing Abutment" to already marketed predicate devices. The studies mentioned are primarily bench tests, biocompatibility evaluations, and sterilization/shelf-life validations, which are standard for physical medical devices. There is no mention of an AI/ML component, AI/ML device performance metrics, or related study methodologies like multi-reader multi-case (MRMC) studies.

    Without information on an AI/ML component, the requested details such as sample size for test sets (for AI), data provenance, expert ground truth establishment, MRMC studies, standalone AI performance, and training set details are not applicable and cannot be provided.

    Ask a Question

    Ask a specific question about this device

    K Number
    K231426

    Validate with FDA (Live)

    Date Cleared
    2024-05-24

    (373 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K122231, K210134, K210161

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    8plant Implant System is indicated for use in partially or fully edentulous mandibles and maxillae, in support of single or multiple unit restorations including; cemented retained, or overdenture restorations, and final or temporary abutment support for fixed bridgework. It is intended for delayed loading. Implant bodies with a diameter of 5mm or more are intended to be used in the molar region.

    Device Description

    8plant Implant System consists of SF Fixtures, Cover Screw, Abutment, and Abutment Screw.

    1. 8plant Implant System (SF Fixtures and Cover Screw)
      This titanium dental implant features a SLA (Sandblasted with Large-grit and Acid-etched) surface with the alveolar bone and is designed to support single or multiple-unit restorations in partially or fully edentulous patients. It is secured to the upper structure using an internal hex fastening system.
    2. 8plant Abutment System (Abutment and Abutment Screw)
      8plant Abutment System is compatible with the SF Fixtures. 8plant Abutment System is intended for use with a dental implant to provide support for prosthetic restorations such as crowns, bridges, or overdentures. The 8plant Abutment System consists of the following; Healing Abutment, Rigid Abutment, Locator Abutment, Transfer Abutment, Angled Abutment, Temporary Abutment, Abutment Screw.
    AI/ML Overview

    The provided document describes a 510(k) premarket notification for the "8plant Implant System." This submission focuses on demonstrating substantial equivalence to a predicate device, rather than providing a detailed study proving the device meets specific acceptance criteria with reported device performance.

    Therefore, the requested information for acceptance criteria and a study proving the device meets them, including specific details like sample sizes, data provenance, number of experts for ground truth, adjudication methods, MRMC studies, standalone performance, type of ground truth used, and training set sample size/ground truth establishment, is not available in this document.

    The document primarily highlights:

    • Substantial Equivalence Comparison: The core of the submission is a comparison of the subject device (8plant Implant System) to a primary predicate device (ZENEX Implant System) and several reference devices. This comparison is presented in tables detailing similarities and differences in intended use, structure, dimensions, material, surface treatment, and sterilization methods for various components (fixture, cover screw, abutments, abutment screw).
    • Non-clinical Testing: The document lists bench tests conducted to "verify that the subject device met all design specifications as was Substantially Equivalent (SE) to the predicate device." These tests were performed to ensure compliance with standards relevant to dental implants:
      • Mechanical Performance: Fatigue testing (ISO 14801:2016).
      • Surface Analysis: Utilizing EDS and SEM evaluations for SLA treated surfaces.
      • Sterilization, Shelf-life, and Packaging: Gamma sterilization validation (ISO 11137 series), End User Sterilization Validation (ISO 11138-1, ISO 17665 series, ISO 11737 series), and real-time aging tests (ASTM F88, ASTM F1929).
      • MR Environment Condition: Non-clinical worst-case MR review based on scientific rationale and published literature.
      • Bacterial Endotoxin: Testing to ensure endotoxin levels are below 0.5 EU/mL (USP <85>).
      • Biocompatibility: Evaluations according to ISO 10993-1 and ISO 10993-12.

    The document concludes that the "results of the below tests have met the standards and demonstrated the substantial equivalence with the predicate device." However, it does not provide specific numerical acceptance criteria or detailed performance data from these tests. It simply states that the device 'met the standards' or 'demonstrated substantial equivalence.'

    Without a dedicated clinical study or further non-clinical performance data with explicit acceptance criteria and corresponding results, it's impossible to fill out the table and provide the in-depth study information requested.

    Ask a Question

    Ask a specific question about this device

    K Number
    K231967

    Validate with FDA (Live)

    Date Cleared
    2023-12-07

    (157 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Predicate For
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The ARi ExCon Implant System is intended to be surgically placed in the maxillary or mandibular molar areas for the purpose providing prosthetic support for dental restorations (Crown, bridges, and overdentures) in partially or fully edentulous individuals. It is used to restore a patient's chewing function in the following situations and with the clinical protocols:

    • Delayed loading

    • Immediate loading when good primary stability is achieved and with appropriate occlusal loading.

    For TiGEN Abutment and ZrGEN Abutment, all digitally designed abutments for use with TiGEN Abutment and ZrGEN Abutment are intended to be sent to a MegaGen-validated milling center for manufacture.

    Device Description

    The ARi ExCon Implant is a substructure of a dental implant system made of CP Ti Grade 4 with the surface treated by SLA method. It is intended to be placed in the maxillary or mandibular areas to restore masticatory function.
    The Abutments are prosthetic components directly or indirectly connected to the endosseous dental implant and are intended for use as an aid in prosthetic rehabilitation, allows single & multiple prosthetic restorations.

    AI/ML Overview

    The provided text is an FDA 510(k) premarket notification summary for the "ARi ExCon Implant System." It details various components of the dental implant system (implants, cover screws, healing abutments, etc.) and compares them to predicate and reference devices to demonstrate substantial equivalence.

    However, the document does not contain information about a study that proves the device meets specific acceptance criteria in the context of an AI/human-in-the-loop performance study, such as an MRMC study. The "Performance test" section on page 25-26 only mentions fatigue testing according to ISO 14801 and "Class II Special Controls Guidance Document: Root-form Endosseous Dental Implants and Endosseous Dental Implant Abutment" to evaluate the performance of subject devices (implant components), and that test results met pre-set criteria. This is a mechanical performance test, not a clinical or human-reader study.

    Therefore, I cannot fulfill the request for information regarding:

    1. A table of acceptance criteria and reported device performance (in the context of AI/human performance).
    2. Sample size for the test set and data provenance.
    3. Number of experts and their qualifications for ground truth.
    4. Adjudication method.
    5. MRMC comparative effectiveness study results or effect size.
    6. Standalone (algorithm-only) performance.
    7. Type of ground truth used (clinical/AI performance).
    8. Training set sample size.
    9. How training set ground truth was established.

    The document primarily focuses on demonstrating substantial equivalence of the dental implant components through material comparisons and mechanical bench testing to predicate and reference devices, not on the performance of a medical AI device or human-in-the-loop performance with AI assistance.

    Ask a Question

    Ask a specific question about this device

    K Number
    K230618

    Validate with FDA (Live)

    Date Cleared
    2023-10-11

    (219 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    -Healing Abutment, Cover Screw (previously cleared per K210826) MegaGen Prosthetics are intended for use as an aid in prosthetic rehabilitation.
    -Multi-unit Abutment, Multi-unit Angled Abutment (previously cleared per K203808) The Multi-unit Abutment, Multi-unit Angled Abutment is intended to be surgically placed in the maxillary or mandbular arches for the purpose providing prosthetic support for dental restorations (Crown, bridges, and overdentures) in partially or fully edentulous individuals.
    -AnyOne External Implant System (previously cleared per K203554) The AnyOne External Implant System is intended to be surgically placed in the maxillary or mandibular molar areas for the purpose providing prosthetic support for dental restorations (Crown, bridges, and overdentures) in partially or fully edentulous individuals. It is used to restore a patient's chewing function. Smaller implants (less than 6.0 mm) are dedicated for immediate loading when good primary stability is achieved and with appropriate occlusal loading, Larger implants are dedicated for the molar region and are indicated for delayed loading.
    -AnyOne Onestage Implant System (previously cleared per K210161) The AnyOne Onestage Implant System is intended to be surgically placed in the maxillary or mandibular arches for the purpose of providing prosthetic support for dental restorations (Crown, bridges, and overdentures) in partially or fully edentulous individuals. It is used to restore a patient's chewing function in the following situations and with the clinical protocols: -Delayed loading. -Immediate loading when good primary stability is achieved and with appropriate occlusal loading. Larger implants are dedicated for the molar region.
    -Meg-Ball Attachment System, Meg-Loc Abutment, Meg-Magnet Abutment (previously cleared per K192614) Meg-Ball Attachment System, Meg-Loc Abutment, Meg-Magnet Abutment is intended to be used in the upper or lower jaw and used for supporting tooth replacements to restore chewing function. Intended for fully edentulous jaw retaining a tissue supported overdenture. The abutments in combination with endosseous implants are used as the foundation for anchoring tooth replacements in either jaw. The attachments are used in fixed overdenture restorations that can be attached with a snap-in system.
    -ST Internal Implant System (previously cleared per K192347) The ST Internal Implant System is intended to be surgically placed in the maxillary or mandibular arches for the purpose providing prosthetic support for dental restorations (Crown, bridges, and overdentures) in partially or fully edentulous individuals. It is used to restore a patient's chewing function. Smaller implants (less than 6.0 mm) are dedicated for immediate loading when good primary stability is achieved and with appropriate occlusal loading. Larger implants are dedicated for the molar region and are indicated for delayed loading.
    -AnyRidge Octa 1 Implant System (previously cleared per K182448) The AnyRidge Octa 1 Implant System is intended to be surgically placed in the maxillary or mandibular arches for the purpose of providing prosthetic support for dental restorations (Crown, bridges, and overdentures) in partially or fully edentulous individuals. It is used to restore a patient's chewing situations and with the clinical protocols: - Delayed loading. - Immediate loading when good primary stability is achieved and with appropriate occlusal loading. Larger implants are dedicated for the molar region.

    • Advanced Intermezzo Implant System (previously cleared per K191127) Advanced Intermezzo Implant Systems is threaded one-piece implants designed for orthodontic onestage surgical procedures in upper and lower jaw to provide a means of prosthetic attachment to restore a patient's chewing function. Advanced Intermezzo Implant System consists of single-stage, root-form dental implants. The system is designed to provide immediate provisional implant to provide temporary support for prosthetic devices during the healing phase of permanent root form implants. Depends on a patient's quality of bone condition, Advanced Intermezzo Fixtures are to be removed within six to ten weeks after the surgery. The system is intended for immediate placement in partially or fully edentulous mandibles and maxillae, in support of single or multiple-unit restorations including; cement retained, screw retained, or overdenture restorations.
      -MiNi Internal Implant System (previously cleared per K150537) The MiNi Internal Implant System is intended for two-stage surgical procedures in the following situations and with the following clinical protocols: - The intended use for the 3.0 mm diameter MiNi implant is limited to the replacement of maxillary lateral incisors and mandibular incisors. - Immediate placement in extraction situations with a partially or completely healed alveolar ridge. - It is intended for delayed loading.
      -XPEED ANYRIDGE INTERNAL IMPLANT SYSYEM (previously cleared per K140091) The Xpeed AnyRidge Internal Implant System is intended to be surgically placed in the maxillary or mandibular molar areas for the purpose providing prosthetic support for dental restorations (Crown, bridges, and overdentures) in partially or fully edentulous individuals. It is used to restore a patient's chewing function. Smaller implants (less than 06.0 mm) are dedicated for immediate loading when good primary stability is achieved and with appropriate occlusal loading. Larger implants are dedicated for the molar region and are indicated for delayed loading.
      -ANYONE™ INTERNAL IMPLANT SYSTEM (previously cleared per K123988) The AnyOne™ Internal Implant System is intended to be surgically placed in the maxillary or mandibular molar areas for the purpose providing prosthetic support for dental restorations (Crown, bridges, and overdentures) in partially or fully edentulous individuals. It is used to restore a patient's chewing function. Smaller implants (less than Ø6.0 mm) are dedicated for immediate loading when good primary stability is achieved and with appropriate occlusal loading. Larger implants are dedicated for the molar region and are indicated for delayed loading.
      -XPEED ANYRIDGE INTERNAL IMPLANT SYSTEM (previously cleared per K123870) The Xpeed®AnyRidge®Intemal Implant System is intended to be surgically placed in the maxillaryor mandbular molar areas for the purpose providing prosthetic support for dental restorations(Crown, bridges, and overdentures) in partially or filly edentulous individuals. It is used to restore a patient's chewing function. Smaller implants (less than Ø6.0mm) are dedicated for immediate loading when good primary stability is achieved and with appropriate occlusal loading. Larger implants are dedicated for the molar region and are indicated for delayed loading.
    Device Description

    Not Found

    AI/ML Overview

    I am sorry, but the provided text does not contain any information about acceptance criteria or a study proving that a device meets such criteria. The document is primarily an FDA 510(k) clearance letter for the "MegaGen Dental Implant Systems Portfolio - MR Conditional." It lists various implant systems and their indications for use, many of which were previously cleared.

    The letter focuses on regulatory approval, substantial equivalence, and compliance with general controls and other FDA regulations for medical devices. It does not include details on specific performance metrics, clinical studies, sample sizes, ground truth establishment, or expert evaluations that would be necessary to answer your request.

    Ask a Question

    Ask a specific question about this device

    K Number
    K222792

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2023-06-08

    (265 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    SNUCONE Tissue Level Implant System is inticated for use in partially or fully edentulous mandibles and maxillae, in support of single or multiple-unit restorations including; cemented retained, or overdenture restorations and terminal or internediate Abutment support for fixed bridge work. Snucone implant system is dedicated for two stage surgical procedures and for immediate loading when there is good primary stability and an appropriate occlusal load. Also, implants with diameters larger than 5mm are indicated for molar regions.

    Device Description

    SNUCONE Implant System Fixture, also known as an endosseous implant, is surgical component that interfaces with the bone of the jaw or skull to support a dental prosthesis such as a crown, bridge, denture. Snucone's abutment and prosthetic components and tools are compatible with the Snucone's fixture only. The system includes Fixtures and Cover Screw, and Abutment and Component (Solid Abutment, InOcta Closing Screw, InOcta Healing Abutment, InOcta Abutment, InOcta Angled Abutment, InOcta Temporary Abutment, Platform Switching Abutment, and Abutment Screw).

    AI/ML Overview

    The provided text is a 510(k) premarket notification for a medical device (SNUCONE Tissue Level Implant System). It contains details about the device, its intended use, comparison to predicate devices, and a list of non-clinical tests performed. However, it does not contain information about acceptance criteria or a study that proves the device meets those criteria, especially in the context of an FDA clearance for an AI/ML-driven device.

    The document explicitly states: "Bench tests were conducted to verify that the subject device met all design specifications as was Substantially Equivalent (SE) to the predicate device." It details mechanical performance, sterilization, shelf-life, packaging, MR environment conditions, bacterial endotoxin, and biocompatibility.

    THERE IS NO MENTION OF AN AI/ML COMPONENT IN THIS DEVICE.

    Therefore, I cannot fulfill your request for information regarding:

    1. A table of acceptance criteria and the reported device performance for an AI/ML component. The document describes acceptance criteria for mechanical, material, and sterilization properties, but not AI/ML performance metrics (e.g., sensitivity, specificity, AUC).
    2. Sample size for test set and data provenance specific to an AI/ML model. The tests mentioned are laboratory bench tests, not data-driven performance studies on patient cohorts for an AI model.
    3. Number of experts and their qualifications for ground truth establishment. This is not relevant to the non-clinical tests described.
    4. Adjudication method for the test set. Not relevant.
    5. MRMC comparative effectiveness study or human reader improvement. Not relevant.
    6. Standalone (algorithm only) performance. Not relevant.
    7. Type of ground truth used (expert consensus, pathology, outcomes data, etc.). Not relevant to the tests performed.
    8. Sample size for the training set. Not relevant, as no AI model is described.
    9. How ground truth for the training set was established. Not relevant, as no AI model is described.

    In summary, the provided document is a 510(k) submission for a physical dental implant system and does not involve any AI/ML components or related performance studies.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1