Found 622 results

510(k) Data Aggregation

    K Number
    K251166
    Device Name
    Mfinity Femoral System
    Manufacturer
    Medacta International S.A.
    Date Cleared
    2025-06-13

    (59 days)

    Product Code
    MEH, KWL, KWY, LPH, LZO
    Regulation Number
    888.3353
    Why did this record match?
    Search-Everything :

    Matched: '888.3358'

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    Mfinity femoral stems are indicated in patients requiring hip arthroplasty. Total or partial hip arthroplasty is indicated in the following cases: - Severely painful and/or disabled joint as a result of osteoarthritis, post-traumatic arthritis, inflammatory arthritis or hip dysplasia. - Avascular necrosis of the femoral head. - Acute fracture of the femoral head. - Acute fracture of the proximal femur, suitable to be treated by means of hip arthroplasty. - Non-union of proximal femur fracture, suitable to be treated by means of hip arthroplasty. - Primary pathology involving the femoral head but with a non-deformed acetabulum. - Failure of previous hip surgery: - Conservative hip surgery. - Internal fixation. - Arthrodesis. - Partial or total hip arthroplasty. - Hip resurfacing replacement.
    Device Description
    The Mfinity Femoral System includes implantable devices provided individually packed, sterile and single-use intended for cementless use in total or partial hip arthroplasty to replace the native femoral neck for primary or revision surgery. The product range is composed of three different versions (Mfinity collarless, Mfinity collared and Mfinity L) available in standard and lateral offset. The Mfinity femoral stem can be combined with the CoCr ball head (K072857, K080885 and K103721), Endo Head (K111145), the MectaCer BIOLOX® forte (K073337), MectaCer BIOLOX® Delta Femoral Heads (K112115) or MectaCer BIOLOX® Option Heads (K131518). The subject devices are made of titanium alloy according to ISO 5832-11 and coated with Titanium plasma spray according to ASTM F1580 and Hydroxyapatite according with ASTM F1185.
    Ask a Question
    K Number
    K243456
    Device Name
    ONVOY™ Acetabular System
    Manufacturer
    Globus Medical, Inc
    Date Cleared
    2025-06-06

    (211 days)

    Product Code
    LPH, LZO, MBL, OQG
    Regulation Number
    888.3358
    Why did this record match?
    Search-Everything :

    Matched: '888.3358'

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The ONVOY Acetabular System is intended for use in reconstruction of the articulating surface of the acetabular portion of the hip that is severely disabled and/or very painful resulting from: 1. Non-inflammatory degenerative joint disease including osteoarthritis, traumatic arthritis, and avascular necrosis. 2. Rheumatoid arthritis. 3. Correction of functional deformity. 4. Treatment of non-union, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement, unmanageable using other techniques. 5. Revision of previously failed total hip arthroplasty. 6. Dislocation risks. The ONVOY Acetabular System is used in conjunction with Globus/StelKast Hip Systems. The acetabular components of this hip system are intended for cementless fixation.
    Device Description
    The ONVOY™ additional implants consist of acetabular shells, liners, and dual mobility liners and bearings that are used as part of a complete total hip system in conjunction with a femoral head and femoral stem in total hip arthroplasty. New femoral head sizes are also being introduced. Implants are available in various configurations and sizes to fit a wide variety of patient anatomy. Shells are available in a cluster-hole design, liners are available in hooded, non-hooded, and lateralized designs used in conjunction with ONVOY shells. Dual mobility polyethylene bearings are used with dual mobility liners. ONVOY™ acetabular shells are additively manufactured from titanium alloy powder per ASTM F3001. Acetabular liners and dual mobility bearings are manufactured from highly crosslinked ultra-high molecular weight polyethylene (UHMWPE) with Vitamin E. Dual mobility liners are manufactured from Cobalt Chrome (CoCr) alloy and femoral heads are manufactured from alumina matrix composite ceramic.
    Ask a Question
    K Number
    K242744
    Device Name
    Trinity EVO Acetabular Shell
    Manufacturer
    Corin USA Limited
    Date Cleared
    2025-06-05

    (267 days)

    Product Code
    LPH, LZO, MBL, OQG, OQI
    Regulation Number
    888.3358
    Why did this record match?
    Search-Everything :

    Matched: '888.3358'

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The indications for the Trinity™ EVO Acetabular Shell as a total hip arthroplasty include: - Non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis. - Rheumatoid arthritis. - Correction of functional deformity. - Developmental dysplasia of the hip (DDH)/Congenital dislocation of the hip (CDH) The Trinity™ EVO acetabular shell is also indicated for use in revisions of a previously failed total hip arthroplasty. The Trinity™ EVO Acetabular Shell is indicated for cementless use only.
    Device Description
    The Trinity™ EVO acetabular shell forms part of a modular acetabular system. The Trinity™ EVO acetabular shell is a hemispherical press fit titanium alloy shell for use with cobalt chrome alloy (Trinity™ Dual Mobility only) or polyethylene liners and a dedicated range of ceramic and cobalt chrome alloy modular 12/14 taper femoral heads providing ceramic on polyethylene and metal on polyethylene articulations for use in total hip arthroplasty (THA) procedures using Corin metal stems with a 12/14 taper connection. The Trinity™ EVO acetabular shell has a porous structure manufactured from titanium alloy powder, produced via additive manufacturing using Laser Powder Bed Fusion (LPBF), and is available with or without an additional layer of electrochemically deposited calcium phosphate. The Trinity™ EVO acetabular shell is provided in sizes permitting the use of titanium bone screws to provide additional fixation, if required. The Trinity™ EVO acetabular shell is also available without screw holes. A titanium occluder is provided to occlude the apical introducer hole. The Trinity™ EVO acetabular shell is intended for use in primary and revision THA in skeletally mature patients, to provide increased mobility and reduce pain by replacing the damaged hip joint articulation when there is evidence of sufficient sound bone to seat and support the components.
    Ask a Question
    K Number
    K251052
    Device Name
    Trivicta® Hip Stem
    Manufacturer
    Ortho Development Corp.
    Date Cleared
    2025-05-22

    (49 days)

    Product Code
    MEH, KWL, LPH, LZO
    Regulation Number
    888.3353
    Why did this record match?
    Search-Everything :

    Matched: '888.3358'

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    This device is intended for use in total and hemi-hip arthroplasty. The device is intended for uncemented, press-fit use only in cases of: 1. Notably impaired hip joint due to osteoarthritis, rheumatoid arthritis, and/or post traumatic arthritis. 2. Previously failed hip surgery. 3. Proximal femoral neck fractures or dislocation. 4. Idiopathic avascular necrosis of the femoral head. 5. Non-union of proximal femoral neck fractures. 6. Treatment of fractures that are unmanageable using other forms of therapy. 7. Benign or malignant bone tumors, congenital dysplasia or other structural abnormalities where sufficient bone stock exists to properly seat the prosthesis.
    Device Description
    The subject device is a set of smaller stems that extends the size range of the previously cleared Trivicta® stems (K233758). Trivicta® is a single-piece, tapered, collared and non-collared, hydroxyapatite (HA) and sintered bead commercially pure (Cp) Titanium coated femoral hip stem designed for single use. The stem has a neck with a 12/14 trunnion taper for modular attachment to femoral heads. Trivicta® is manufactured from titanium alloy and device fixation is achieved through uncemented press-fit in the medullary canal and through the use of biocompatible HA coating and porous sintered bead coating. The size range of the subject device is: lengths (97-101mm), horizontal offsets (36-43mm), vertical offsets (27-29mm), resection angle of 41°, and neck angle of 132°. The stem is offered with both standard (STD) and extended (EXT) offsets and with and without a collar. Trivicta® is compatible with the following Ortho Development® devices: CoCr Femoral Heads, Biolox Delta Ceramic Femoral Heads, Solitude™ Unipolar Head, Escalade Acetabular Cup System, Legend® Acetabular Liner, Escalade Legend® Acetabular Shell, and Tri-plus™ DCM Liner.
    Ask a Question
    K Number
    K243043
    Device Name
    Origin™ Cemented Hip Stem
    Manufacturer
    Signature Orthopaedics Pty Ltd
    Date Cleared
    2025-05-02

    (217 days)

    Product Code
    LZO, KWL, KWY, KWZ, LPH, OQG, OQI
    Regulation Number
    888.3353
    Why did this record match?
    Search-Everything :

    Matched: '888.3358'

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    Components of the Signature Orthopaedics hip replacement range are intended to replace a hip joint where bone stock is sufficient to support the implant. When a surgeon has selected prosthetic replacement as the preferred treatment, the devices are indicated for: - Non-inflammatory degenerative joint disease including osteoarthritis or avascular necrosis - Inflammatory joint disease including rheumatoid arthritis - Correction of functional deformity including congenital hip dysplasia - Traumatic injury involving the hip joint including traumatic arthritis or femoral head or neck fracture - Failed previous hip surgery including internal fixation or joint fusion, reconstruction, hemiarthroplasty, surface replacement, or total replacement Signature Orthopaedics' Origin, Origin TT, Aria, Remedy, Origin-NS, Pegasus, Spartan, World and Everglade Hip femoral stems, SignaSure Cementless Cups, Logical and World Acetabular Cups are intended for cementless fixation only. Signature Orthopaedics' Evolve, Cemented TSI (both CoCr and HNSS variants), and Origin Cemented femoral stems and SignaSure Cemented Cups are intended for cemented fixation only. Signature Orthopaedics' SignaSure Logical/World Metal Insert is indicated for use with a cementless Signature Orthopaedics' Logical/World Acetabular Cup to provide dual mobility articulation. Signature Orthopaedics' constrained liner components are indicated particularly for patients at high risk of hip dislocation due to a history of prior dislocation, bone loss, joint or soft tissue laxity, neuromuscular disease or intraoperative instability. Signature Orthopaedics' Evolve UniPolar Head and BiPolar Head are intended for hemi-hip arthroplasty only, where the natural acetabulum does not require replacement. The Evolve UniPolar Head and BiPolar Head are indicated for bone fractures or pathologies involving only the femoral head/neck and/or proximal femur, such as: - Acute femoral head or neck fracture - Fracture dislocation of the hip - Avascular necrosis of the femoral head - Non-union of femoral neck fractures - Certain high subcapital and femoral neck fractures in the elderly - Degenerative arthritis involving only the femoral head
    Device Description
    Signature Orthopaedics' Origin™ Cemented Hip Stems are manufactured from nitrogen stainless steel per ASTM F1568 and ISO 5832-9. The subject stem is straight and tapered with a lateral chamfer. The Cemented Origin™ stem is polished and intended for cemented use in total hip arthroplasty. It features a 12/14 taper which allows for compatibility with Signature Orthopaedics' range of previously cleared femoral head components including the Signature CoCr Femoral Heads (K121297 and K163081), Signature Ceramic Femoral Heads (K190704), Signature BiPolar Head (K133370 and K163081) and Evolve UniPolar Head (K143184). Compatible acetabular cups and liners including the Logical Cup (G-Series K121297, PX-Series K121297 and C-Series K153131) and the Logical Liners (Neutral and 10º Hooded, Lateralised K121297), Logical Liners (20º Hooded, Lateralised 20º Hooded K153131), Logical Constrained Liners (K153131) and Logical Liners Vit-E (Neutral and 10º Hooded, Lateralised, 20º Hooded, Lateralised 20º Hooded, High Wall, 10º Face Changing (K241690).
    Ask a Question
    K Number
    K242232
    Device Name
    Mpact 3D Metal Augments II
    Manufacturer
    Medacta International S.A.
    Date Cleared
    2025-04-23

    (267 days)

    Product Code
    LPH
    Regulation Number
    888.3358
    Why did this record match?
    Search-Everything :

    Matched: '888.3358'

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    Mpact 3D Metal Augments are intended for cementless use to the bone interface and are affixed to a compatible Medacta Acetabular shell using bone cement in hip replacement surgeries. Mpact 3D Metal Augments are indicated in cases of: - Acetabular dysplasia; - Acetabular fractures; - Revision of previous implants in the presence of insufficient bone quality or seriously altered bone structures.
    Device Description
    The Mpact 3D Metal Augment II is an acetabular implant intended to be used in Total Hip Arthroplasty cemented to its Medacta compatible Acetabular Shell. It is provided sterile and individually packaged to the end user. The devices subject of this submission are: - Mpact 3D Metal Augments II from size Ø46 to Ø80, made of Ti6Al4V according to ASTM F2924; - Double Augment Technique Screw, made of Ti6Al4V according to ISO 5832-3. The Mpact 3D Metal Augments II represent the second generation of the Mpact 3D Metal Augments cleared within K171966.
    Ask a Question
    K Number
    K242045
    Device Name
    Initia T3 Acetabular Hemispherical Shell System
    Manufacturer
    Kyocera Medical Technologies, Inc.
    Date Cleared
    2025-04-10

    (272 days)

    Product Code
    LPH, LZO
    Regulation Number
    888.3358
    Why did this record match?
    Search-Everything :

    Matched: '888.3358'

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The KMTI Hip Replacement System is indicated for patients suffering from: 1. Non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis; 2. Rheumatoid arthritis; 3. Correction of functional deformity; 4. Treatment of non-union, femoral neck fracture and trochanteric fractures of the proximal femur with head involvement, unmanageable using other techniques; and 5. Revision procedures where other treatment or devices have failed. The Initia T3 Acetabular Hemispherical Shell System is intended for cementless applications.
    Device Description
    The Kyocera Medical Technologies, Inc. (KMTI) Initia T3 Acetabular Hemispherical Shell System is a cementless shell intended for use in the treatment of hip disorders requiring hip replacement surgery. The Initia T3 Acetabular Hemispherical Shell System includes several components including: Initia T3 Acetabular Hemispherical Shell, Initia Acetabular Liner, Initia Bone Screw, and Delta 22.2 Femoral Head. The Initia T3 Acetabular Hemispherical Shell is a cementless porous shell manufactured from Ti-6Al-4V ELI per ASTM F136. The Initia Acetabular Liner attaches to the inner surface of the Initia T3 Acetabular Hemispherical Shell and is available in four different configurations. The Initia Acetabular Liner is used to provide a single articulation implant option and is manufactured from Vitamin E infused UHMWPE per ASTM F2695 or UHMWPE per ASTM F648. The femoral head is manufactured from Biolox® delta and is available in two offsets.
    Ask a Question
    K Number
    K243029
    Device Name
    Origin™ TT Stem
    Manufacturer
    Signature Orthopaedics Pty Ltd
    Date Cleared
    2025-03-11

    (165 days)

    Product Code
    LZO, KWL, KWY, KWZ, LPH, MEH, OQG, OQI
    Regulation Number
    888.3353
    Why did this record match?
    Search-Everything :

    Matched: '888.3358'

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    Components of the Signature Orthopaedics hip replacement range are intended to replace a hip joint where bone stock is sufficient to support the implant. When a surgeon has selected prosthetic replacement as the preferred treatment, the devices are indicated for: - · Non-inflammatory degenerative joint disease including osteoarthritis or avascular necrosis - · Inflammatory joint disease including rheumatoid arthritis - · Correction of functional deformity including congenital hip dysplasia - · Traumatic injury involving the hip joint including traumatic arthritis or femoral head or neck fracture - Failed previous hip surgery including internal fixation or joint fusion, reconstruction, hemiarthroplasty, surface replacement, or total replacement Signature Orthopaedics' Origin TT, Aria, Remedy, Origin-NS, Pegasus, Spartan, World and Everglade Hip femoral stems, SignaSure Cementless Cups, Logical and World Acetabular Cups are intended for cementless fixation only. Signature Orthopaedics' Evolve, Cemented TSI (both CoCr and HNSS variants), Origin Cemented femoral stems and SignaSure Cemented Cups are intended for cemented fixation only. Signature Orthopaedics' SignaSure Logical/World Metal Insert is indicated for use with a cementless Signature Orthopaedics' Logical/World Acetabular Cup to provide dual mobility articulation. Signature Orthopaedics' constrained liner components are indicated particularly for patients at high risk of hip dislocation due to a history of prior dislocation, bone loss, joint or soft tissue laxity, neuromuscular disease or intraoperative instability. Signature Orthopaedics' Evolve UniPolar Head and BiPolar Head are intended for hemi- hip arthroplasty only, where the natural acetabulum does not require replacement. The Evolve UniPolar Head are indicated for bone fractures or pathologies involving only the femoral head/neck and/or proximal femur, such as: - · Acute femoral head or neck fracture - · Fracture dislocation of the hip - · Avascular necrosis of the femoral head - · Non-union of femoral neck fractures - · Certain high subcapital and femoral neck fractures in the elderly - · Degenerative arthritis involving only the femoral head
    Device Description
    The Signature Orthopaedics Origin™ TT Stem is intended for single use and cementless fixation. It is manufactured from titanium alloy as per ISO 5832-3 and has a proximal plasma spray coating of titanium as per ASTM F1580 and hydroxyapatite as per ISO 13779-2. It features a 12/14 taper and is compatible for use with Signature CoCr Femoral Heads (K121297 and K163081), Ceramic Femoral Heads (K190704), Logical™ PX, G and C Series Acetabular Cups (K121297 and K153131), Logical™ Liners (K121297, K153131 and K241690), Logical™ Constrained Liners (K153131), BiPolar Heads (K133370 and K163081) and Evolve™ UniPolar Heads (K143184).
    Ask a Question
    K Number
    K243809
    Device Name
    Biolox® Delta Revision heads
    Manufacturer
    Limacorporate
    Date Cleared
    2025-03-04

    (83 days)

    Product Code
    LZO, LPH
    Regulation Number
    888.3353
    Why did this record match?
    Search-Everything :

    Matched: '888.3358'

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    LimaCorporate Femoral modular heads are intended to be used in Total Hip arthroplasty with compatible femoral and acetabular components. - Coupling of femoral modular heads with DELTA Acetabular System is indicated for use for reduction or relief of pain and/or improved hip function in skeletally mature patients with the following conditions: - · Non-inflammatory degenerative joint disease such as osteoarthritis, avascular necrosis and hip dysplasia; - · Rheumatoid arthritis; - · Post-traumatic arthritis, - · Correction of functional deformity; - · Fractures, dislocation of the hip and unsuccessful cup arthroplasty; - · Revisions in cases of good remaining bone stock. - · Revision of previously failed total hip arthroplasty (DELTA Multihole TT Pro only) The components are intended for use in cementless (press-fit) applications. - Coupling of femoral modular heads with H-MAX S, Minima S, Master SL, C2, MODULUS femoral stems is indicated for reduction or relief of pain and/or improved hip function in skeletally mature patients with the following conditions: · non-inflammatory degenerative joint disease such as osteoarthritis, avascular necrosis and hip dysplasia; - · rheumatoid arthritis; - · osteoarthritis after femoral heads fractures (H-MAX S and Modulus stem); - · treatment of femoral head and neck fractures (Minima S and MasterSL stems) - · correction of functional deformity (MODULUS stems); - · revisions in cases of good remaining femoral bone stock. The components are intended for use in cementless (press-fit) applications. - Coupling of femoral modular heads with Revision Femoral Stem is indicated for patients whose bone stock is of poor quality or inadequate for other reconstruction techniques as indicated by deficiencies of the femoral head, neck or portions of the proximal femur. The components are intended for use in cementless (press-fit) applications. - Coupling of femoral modular heads with Cemented Cup is intended applications in hip arthroplasty where the acetabular socket needs reconstruction. LimaCorporate Lock Bipolar femoral heads are intended to be used in Partial Hip replacement with compatible femoral components (Minima S, Master SL, C2, MODULUS femoral stems) for cementless applications. This procedure is intended for redict of pain and/or improved hip function in skeletally mature patients with the following conditions: treatment of non-union, femoral neck fracture and intertrochanteric fractures unmanageable by other techniques.
    Device Description
    Biolox® Delta Revision heads consist of a Biolox® Delta ball head and a titanium sleeve (Ti6Al4V). The ball heads are made of the Biolox® Delta ceramic material (K141327, K182099) and come in various outer diameters. The ceramic Biolox® Delta ball head is assembled with the corresponding titanium sleeve and is then placed over the taper of an in-situ hip stem prosthesis, during revision of a previously implanted femoral head: K170473, K112091, K160011, K140975, K151739, K161226, K141327, K143509, K150855 The titanium sleeve has an inner 12/14 taper which fits the dimensions of a metallic hip stem prosthesis, and the Biolox® Delta ball head has a 16/18 taper which fits to the dimensions of the outer diameter of the titanium sleeve. The ball head then articulates against an acetabular insert: K112898, K141395, K182099, K181491, K191622, K200656 The titanium sleeves are available in sizes -3, 0, +4, and +7 (S, M, L, XL) and the ball heads of the Biolox® Delta Revision heads are available with outer diameters ranging from 28mm - 40 mm.
    Ask a Question
    K Number
    K243784
    Device Name
    Stryker Orthopaedics Hip Devices Labeling Update
    Manufacturer
    Howmedica Osteonics Corp. dba Stryker Orthopaedics
    Date Cleared
    2025-02-06

    (59 days)

    Product Code
    LPH, JDG, JDI, KWL, KWY, KWZ, LWJ, LZN, LZO, MAY, MBL, MEH
    Regulation Number
    888.3358
    Why did this record match?
    Search-Everything :

    Matched: '888.3358'

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    Indications for Restoration Modular Hip System - · Noninflammatory degenerative joint disease, including osteoarthritis and avascular necrosis: - · Rheumatoid arthritis; - · Correction of functional deformity; - · Revision procedures where other treatments or devices have failed; and, · Nonunions, femoral neck fractures, and trochanteric fractures of the proximal femur with head involvement that are unmanageable using other techniques. · The RESTORATION Modular Hip System is intended for primary and revision total hip arthroplasty as well as in the presence of severe proximal bone loss. These femoral stems are designed to be proximal femur. Indications for Accolade C, Accolade HFx, SYSTEM 12 CROSSFIRE, ACCOLADE DISTAL SPACER, CITATION TMZF, PCA Duration Insert, PCA Femoral Head - · Noninflammatory degenerative joint disease, including osteoarthritis and avascular necrosis; - · Rheumatoid arthritis; - · Correction of functional deformity; - · Revision procedures where other treatments or devices have failed; and, · Nonunions, femoral neck fractures, and trochanteric fractures of the proximal femur with head involvement that are unmanageable using other techniques Indications for Accolade II Stems The indications for use of the total hip replacement prostheses include: - · noninflammatory degenerative joint disease, including osteoarthritis and avascular necrosis; - rheumatoid arthritis; - · correction of functional deformity; - · revision procedures where other treatments or devices have failed; and. · nonunions, femoral neck and trochanteric fractures of the proximal femur with head involvement that are unmanageable using other techniques. Additional indication specific to use of ACCOLADE II Femoral Stems with compatible Howmedica Osteonics Constrained Liners · When the stem is to be used with compatible Howmedica Osteonics Constrained Liners, the device is intended for use in primary or revision patients at high risk of hip dislocation due to a history of prior dislocation, bone loss, soft tissue laxity, neuromuscular disease, or intraoperative instability. ACCOLADE II Femoral Stems are intended for cementless use only and are intended for total and hemiarthroplasty procedures. Indications for OMNIFIT SERIES Acetbular Inserts, Omnifit Crossfire 10 Deg Inserts, Crossfire Inserts, Omnifit Crossfire Inserts, Trident Crossfire Inserts, Trident X3 Inserts, Trident X3 Eccentric Inserts · Painful, disabling joint disease of the hip from: degenerative arthritis, theumatoid arthritis, posttraumatic arthritis or late stage avascular necrosis. · Revision of previous unsuccessful femoral head replacement, cup arthroplasty or other procedure. · Clinical management problems where arthrodesis or alternative techniques are less likely to achieve satisfactory results. · Where bone stock is of poor quality or inadequate for other reconstructive techniques as indicated by deficiencies of the acetabulum. Indications for ALL POLY CONSTRAINED INSERT, TRIDENT 0 DEG CONSTRAINED INSERT, TRIDENT CONSTRAINED INSERT A Constrained Acetabular Insert is indicated for use as a component of a total hip prosthesis in primary and revision patients at high risk of hip dislocation due to a history of prior dislocation, bone loss, joint or soft tissue laxity, neuromuscular disease, or intraoperative instability. Indications for UHR Bipolar - · Femoral head/neck fractures or non-unions. - · Aseptic necrosis of the femoral head. · Osteo-, rheumatoid, and post-traumatic arthritis of the hip with minimal acetabular involvement or distortion. Other Considerations: · Pathological conditions or age considerations which indicate a more conservative acetabular procedure and an avoidance of the use of bone cement in the acetabulum. · Salvage of failed total hip arthroplasty Indications for Artisan Bone Plug These bone plugs are intended to be placed in the femoral canal prior to the introduction of bone cemented hip procedure. The plug is placed distally to the femoral stem to help allow cement pressurization and to help prevent cement migration further down the femoral canal. Indications for C-Taper Alumina Ceramic Heads, V40 Taper Alumina Ceramic V40™ Femoral Head • Painful, disabling joint disease of the hip from: degenerative arthritis, theumatoid arthritis, posttraumatic arthritis or late stage avascular necrosis. · Revision of previous unsuccessful femoral head replacement, cup arthroplasty or other procedure. · Clinical management problems where arthrodesis or alternative techniques are less likely to achieve satisfactory results. • Where bone stock is of poor quality or is inadequate for other reconstructive techniques as indicated by deficiencies of the acetabulum Indications for BIOLOX Delta Ceramic Heads, C-Taper to Universal Taper Adapter Sleeve, Universal V40™ Taper Adapter Sleeve For Use as a Total Hip Replacement: · Painful disabling joint disease of the hip resulting from: degenerative arthritis, rheumatic arthritis or late stage avascular necrosis. • Revision of previous cup arthroplasty or other procedures · Clinical management problems where arthrodesis or alternative techniques are less likely to achieve satisfactory results. · Where bone stock is of poor quality or is inadequate for other reconstructive techniques as indicated by deficiencies in the acetabulum. For Use as a Bipolar Hip Replacement - · Femoral head/neck fractures or non-unions. · Aseptic necrosis of the femoral head. • Osteo-, rheumatoid, and post traumatic arthritis of the hip with minimal acetabular involvement or distortion. · Pathological considerations or age considerations which indicate a more conservative acetabular procedure and an avoidance of the use of bone cement in the acetabulum. · Salvage of failed total hip arthroplasty Indications for ADM/MDM X3 Inserts, MDM Acetabular Inserts, MDM Acetabular Liners The indications for use for total hip arthroplasty include: 1. Noninflammatory degenerative joint disease including osteoarthritis and avascular necrosis; 2. Rheumatoid arthritis; 3. Correction of functional deformity; 4. Revision procedures where other treatments or devices have failed; and, 5. Treatment of nonunion, femoral neck and trochanteric fractures of the proximal femur with head involvement that are unmanageable using other techniques. 6. Dislocation risks MDM Liners are intended for cementless use only.
    Device Description
    The devices included in this submission are femoral heads, acetabular inserts, distal spacers, and bone plugs, used in hip arthroplasty procedures. All devices have been previously deemed substantially equivalent in prior premarket submissions and are commercially available.
    Ask a Question

    Page 1 of 63