21 CFR 876.5820 — Dialyzer, Single Coil

Gastroenterology, Urology (GU) · Subpart F—Therapeutic Devices · § 876.5820

Identification

A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer.(1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air foam or bubble detectors, and alarms to keep blood moving safely from the blood access device and accessories for hemodialysis (§ 876.5540) to the blood compartment of the dialyzer and back to the patient. (2) The conventional dialyzer allows a transfer of water and solutes between the blood and the dialysate through the semipermeable membrane. The semipermeable membrane of the conventional dialyzer has a sufficiently low permeability to water that an ultrafiltration controller is not required to prevent excessive loss of water from the patient's blood. This conventional dialyzer does not include hemodialyzers with the disposable inserts (Kiil type) (§ 876.5830) or dialyzers of high permeability (§ 876.5860). (3) The dialysate delivery system consists of mechanisms that monitor and control the temperature, conductivity, flow rate, and pressure of the dialysate and circulates dialysate through the dialysate compartment of the dialyzer. The dialysate delivery system includes the dialysate concentrate for hemodialysis (liquid or powder) and alarms to indicate abnormal dialysate conditions. This dialysate delivery system does not include the sorbent regenerated dialysate delivery system for hemodialysis (§ 876.5600), the dialysate delivery system of the peritoneal dialysis system and accessories (§ 876.5630), or the controlled dialysate delivery system of the high permeability hemodialysis system § 876.5860). (4) Remote accessories to the hemodialysis system include the unpowered dialysis chair without a scale, the powered dialysis chair without a scale, the dialyzer holder set, dialysis tie gun and ties, and hemodialysis start/stop tray.

Classification Rationale

(1) Class II (performance standards) for hemodialysis systems and all accessories directly associated with the extracorporeal blood system and the dialysate delivery system.(2) Class I for other accessories of the hemodialysis system remote from the extracorporeal blood system and the dialysate delivery system, such as the unpowered dialysis chair, hemodialysis start/stop tray, dialyzer holder set, and dialysis tie gun and ties. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.

Product Codes

Product CodeDevice NameClassDevicesAttributes
FHSDialyzer, Single Coil212Life-Sustaining
FIAChair, Dialysis, Unpowered, Without Scales10
FIBProtector, Transducer, Dialysis235Life-Sustaining
FIDTubing, Dialysate23Life-Sustaining
FIFSet, Dialysis, Single Needle With Uni-Directional Pump26Life-Sustaining
FIGClamp, Tubing, Blood, Automatic24Life-Sustaining
FIHPump, Infusion Or Syringe, Extra-Luminal25Life-Sustaining
FIJSystem, Dialysate Delivery, Recirculating, Single Pass21Life-Sustaining
FIKSystem, Dialysate Delivery, Recirculating20Life-Sustaining
FILSystem, Dialysate Delivery, Single Pass28Life-Sustaining
FINTank, Holding, Dialysis2183rd Party
FIRPump, Blood, Extra-Luminal27Life-Sustaining
FISFlowmeter, Dialysate20Life-Sustaining
FIWAlarm, Pillow Pressure21Life-Sustaining
FIZMeter, Conductivity, Non-Remote213Life-Sustaining
FJAManometer, Water203rd Party
FJBDetector, Dialysate Level23Life-Sustaining
FJCDetector, Blood Level21Life-Sustaining
FJDDetector, Leak, Blood24Life-Sustaining
FJFDetector, Air Bubble25Life-Sustaining
FJGDialyzer, Parallel Flow236Life-Sustaining
FJIDialyzer, Capillary, Hollow Fiber2131Life-Sustaining
FJJDialyzer, Twin Coil20Life-Sustaining
FJKSet, Tubing, Blood, With And Without Anti-Regurgitation Valve276Life-Sustaining
FJPAdaptor, Y203rd Party
FJTIntracatheter, Dialysis25Life-Sustaining
FJZDeclotting Tray, Kit (Including Contents)233rd Party
FKBConnector, Blood Tubing, Infusion T22Life-Sustaining
FKDCanister, Coil21Life-Sustaining
FKETie, Dialysis10
FKFGun, Tie, Dialysis10
FKGTray, Start/Stop (Including Contents), Dialysis16
FKHSolution-Test Standard-Conductivity, Dialysis283rd Party
FKISet, Dialyzer Holder23
FKJFilter, Blood, Dialysis25Life-Sustaining
FKLInsert, Pump, Blood21Life-Sustaining
FKMAdaptor, Fistula203rd Party
FKPSystem, Dialysate Delivery, Single Patient250Life-Sustaining
FKQSystem, Dialysate Delivery, Central Multiple Patient261Life-Sustaining
FKRSubsystem, Proportioning212Life-Sustaining
FKYConnector, Tubing, Dialysate24Life-Sustaining
FLAMonitor, Temperature, Dialysis23Life-Sustaining
FLBMeter, Conductivity, Induction, Remote Type263rd Party
FLCStation, Dialysis Control, Negative Pressure Type24Life-Sustaining
KOCAccessories, Blood Circuit, Hemodialysis2182Life-Sustaining
KPODialysate Concentrate For Hemodialysis (Liquid Or Powder)2123Life-Sustaining
KQQTubing, Dialysate (And Connector)21Life-Sustaining
KQRDetector, Air Or Foam20Life-Sustaining
KXMSystem Accessories, Extracorporeal24Life-Sustaining
LIFDialyzer Reprocessing System257
LLBSystem, Blood, Extracorporeal And Accessories22Life-Sustaining
LRIPh Meter For Dialysis Hydrogen Ion Concentration21Life-Sustaining
MNVStrip, Dialysate Ph Indicator263rd Party
MONSystem, Hemodialysis, Remote Accessories10
MQSSystem, Hemodialysis, Access Recirculation Monitoring218Life-Sustaining
MSEHemodialyzer, Re-Use, Low Flux27Life-Sustaining
NNGSet, Dialysis, Single Needle With Uni-Directional Pump, Reprocessed20
NTZStrip, Dialysate, Ph, Bicarbonate, Glucose, Acid, Indicator21
ODXAutonomous Extracorporeal Blood Leak Detector/Alarm24
PEVDialysis Administration Kit20
PPHSingle Needle With Uni-Directional Pump Kit20
PPIHemodialysis Tray (Not A Start/Stop Kit)20
PPLSingle Needle (Co-Axial Flow) Dialysis Kit20
PROAnti-Regurgitation Blood Tubing Kit20
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...