KOC · Accessories, Blood Circuit, Hemodialysis

Gastroenterology, Urology · 21 CFR 876.5820 · Class 2

Overview

Product CodeKOC
Device NameAccessories, Blood Circuit, Hemodialysis
Regulation21 CFR 876.5820
Device ClassClass 2
Review PanelGastroenterology, Urology
Life-SustainingYes

Identification

A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer.(1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air foam or bubble detectors, and alarms to keep blood moving safely from the blood access device and accessories for hemodialysis (§ 876.5540) to the blood compartment of the dialyzer and back to the patient. (2) The conventional dialyzer allows a transfer of water and solutes between the blood and the dialysate through the semipermeable membrane. The semipermeable membrane of the conventional dialyzer has a sufficiently low permeability to water that an ultrafiltration controller is not required to prevent excessive loss of water from the patient's blood. This conventional dialyzer does not include hemodialyzers with the disposable inserts (Kiil type) (§ 876.5830) or dialyzers of high permeability (§ 876.5860). (3) The dialysate delivery system consists of mechanisms that monitor and control the temperature, conductivity, flow rate, and pressure of the dialysate and circulates dialysate through the dialysate compartment of the dialyzer. The dialysate delivery system includes the dialysate concentrate for hemodialysis (liquid or powder) and alarms to indicate abnormal dialysate conditions. This dialysate delivery system does not include the sorbent regenerated dialysate delivery system for hemodialysis (§ 876.5600), the dialysate delivery system of the peritoneal dialysis system and accessories (§ 876.5630), or the controlled dialysate delivery system of the high permeability hemodialysis system § 876.5860). (4) Remote accessories to the hemodialysis system include the unpowered dialysis chair without a scale, the powered dialysis chair without a scale, the dialyzer holder set, dialysis tie gun and ties, and hemodialysis start/stop tray.

Classification Rationale

(1) Class II (performance standards) for hemodialysis systems and all accessories directly associated with the extracorporeal blood system and the dialysate delivery system.(2) Class I for other accessories of the hemodialysis system remote from the extracorporeal blood system and the dialysate delivery system, such as the unpowered dialysis chair, hemodialysis start/stop tray, dialyzer holder set, and dialysis tie gun and ties. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.

Recent Cleared Devices (20 of 182)

Showing 20 most recent of 182 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K242479BLOOD TUBING LINES FOR HEMODIALYSIS AL Series (Archloop) BLOOD TUBING LINES FOR HEMODIALYSIS C18 Series AL-ADC-PU, AL-CDC-PU, C18RDC-PU, C18BDD-PU, C18SFD-PUNIKKISO CO., LTD.May 15, 2025SESE
K242176BLOOD TUBING LINES FOR HEMODIALYSIS AL Series (Archloop) BLOOD TUBING LINES FOR HEMODIALYSIS C18 Series (AL-ADC-E(U), AL-CDC-E(U), C18RDC-E(U), C18BDD-E(U), C18SFD-E(U)NIKKISO CO., LTD.May 15, 2025SESE
K231589Blood Tubing Lines for Hemodialysis AV06C-ENIKKISO CO., LTD.Jul 28, 2023SESE
K230514Blood Tubing Lines for Hemodialysis AL Series (Archloop), Blood Tubing Lines for Hemodialysis C18 SeriesNIKKISO CO., LTD.Jun 16, 2023SESE
K201207CombiSet SMARTECH Hemodialysis Blood Tubing Set with attached Priming Set and Integrated Crit-Line Technology, CombiSet SMARTECH Hemodialysis Blood Tubing Set with attached Priming Set and Intergrated Crit-Line Technology, no Heparin LineFresenius Medical Care Renal Therapies Group, LLCSep 18, 2020SESE
K172238CAREline Airless Hemodialysis Blood Tubing SetsFresenius Medical Care Renal Therapies Group, LLCDec 14, 2017SESE
K160749CRIT-LINE III Blood Chamber IIFresenius Medical Care Renal Therapies Group, LLCApr 15, 2016SESE
K152953CRIT-LINE CLIP (CLIC) BLOOD CHAMBERFresenius Medical Care North AmericaNov 5, 2015SESE
K141997CRIT-LINE IV SYSTEMFresenius Medical CareApr 1, 2015SESE
K141281CRIT-LINE CLIP (CLIC) BLOOD CHAMBERFresenius Medical Care Renal Therapies Group, LLCAug 14, 2014SESE
K121599CRIT-LINE CLIP (CLIC)Fresenius Medical Care-North AmericaNov 9, 2012SESE
K082719NIKKLINE BLOOD TUBING LINES WITH TRANSDUCER PROTECTORS, MODELS AV06A-P, AVO6B-P, AV06C-PNIKKISO CO., LTD.Mar 30, 2009SESE
K081740HEMOBAND, MODELS HB-NS AND HB-NSXLInnovations For Access, Inc.Mar 12, 2009SESE
K082758PRISMAFLO IIStihler Electronic GmbHDec 19, 2008SESE
K081043LEAK DETECTION SENSOR AND TRAY ACCESSORY KITNxstage Medical, Inc.Jul 7, 2008SESE
K071909PRISMACOMFORT, MODEL AUTOCONTROL 3XPT WITH AUTOLINE XPT 4RBarkey GmbH & Co. KGOct 18, 2007SESE
K030456VASC-ALERTVasc-Alert, LLCJul 11, 2003SESE
K022536\RESENIUS ACCESS FLOW RESERVING CONNECTORS, FRESENIUS STANDALONE ACCCES FLOW RESERVING CONNECTORFresenius Medical CareOct 30, 2002SESE
K020103PRISMAFLOStihler Electronic GmbHJul 24, 2002SESE
K003712MODIFICATION TO MALE TO MALE LUER ADAPTERMolded Products, Inc.May 16, 2001SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...