MQS · System, Hemodialysis, Access Recirculation Monitoring

Gastroenterology, Urology · 21 CFR 876.5820 · Class 2

Overview

Product CodeMQS
Device NameSystem, Hemodialysis, Access Recirculation Monitoring
Regulation21 CFR 876.5820
Device ClassClass 2
Review PanelGastroenterology, Urology
Life-SustainingYes

Identification

A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer.(1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air foam or bubble detectors, and alarms to keep blood moving safely from the blood access device and accessories for hemodialysis (§ 876.5540) to the blood compartment of the dialyzer and back to the patient. (2) The conventional dialyzer allows a transfer of water and solutes between the blood and the dialysate through the semipermeable membrane. The semipermeable membrane of the conventional dialyzer has a sufficiently low permeability to water that an ultrafiltration controller is not required to prevent excessive loss of water from the patient's blood. This conventional dialyzer does not include hemodialyzers with the disposable inserts (Kiil type) (§ 876.5830) or dialyzers of high permeability (§ 876.5860). (3) The dialysate delivery system consists of mechanisms that monitor and control the temperature, conductivity, flow rate, and pressure of the dialysate and circulates dialysate through the dialysate compartment of the dialyzer. The dialysate delivery system includes the dialysate concentrate for hemodialysis (liquid or powder) and alarms to indicate abnormal dialysate conditions. This dialysate delivery system does not include the sorbent regenerated dialysate delivery system for hemodialysis (§ 876.5600), the dialysate delivery system of the peritoneal dialysis system and accessories (§ 876.5630), or the controlled dialysate delivery system of the high permeability hemodialysis system § 876.5860). (4) Remote accessories to the hemodialysis system include the unpowered dialysis chair without a scale, the powered dialysis chair without a scale, the dialyzer holder set, dialysis tie gun and ties, and hemodialysis start/stop tray.

Classification Rationale

(1) Class II (performance standards) for hemodialysis systems and all accessories directly associated with the extracorporeal blood system and the dialysate delivery system.(2) Class I for other accessories of the hemodialysis system remote from the extracorporeal blood system and the dialysate delivery system, such as the unpowered dialysis chair, hemodialysis start/stop tray, dialyzer holder set, and dialysis tie gun and ties. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.

Recent Cleared Devices (18 of 18)

RecordDevice NameApplicantDecision DateDecision
K232283PhySoftAMS®Physician Software Systems, LLCDec 14, 2023SESE
K180410Dosis SAMDosis, Inc.Jan 16, 2019SESE
K130579PHYSOFT AMSPhysicians Software Systems, LLCDec 19, 2013SESE
K042566VASC-ALERTVasc-Alert, Inc.Nov 8, 2004SESE
K022963TRANSONIC SYRINGE WARMER, MODEL SYR-1000Transonic Systems, Inc.Dec 4, 2002SESE
K021571TRANSONIC FLOW-QC SET MODEL ADT1010Transonic Systems, Inc.Aug 12, 2002SESE
K001763CRIT-LINE MONITOR III (CLM III)In-Line Diagnostics Corp.Dec 20, 2000SESE
K993587HP M2376A DEVICE LINK SYSTEMHewlett-Packard Co.Jan 20, 2000SESE
K992227CRIT-LINE MONITOR III (CLM III)In-Line Diagnostics Corp.Jul 30, 1999SESE
K984194HP M2376A DEVICE LINK SYSTEMHewlett-Packard Co.Apr 30, 1999SESE
K982412MODIFICATION OF CRIT-LINE MONITOR III (CLM III)In-Line Diagnostics Corp.Oct 9, 1998SESE
K980906TRANSONIC HEMODIALYSIS MONITOR, CARDIAC OUTPUT, MODEL HD01-COTransonic Systems, Inc.Oct 6, 1998SESE
K972470CRIT-LINE MONITOR (CLMIII)In-Line Diagnostics Corp.Dec 11, 1997SESE
K960817HD01-SERIES TRANSONIC HEMODIALYSIS MONITOR (R%,QA,CO,QB,QB2)Transonic Systems, Inc.Feb 11, 1997SESE
K954003COBE HEMODYNAMIC RECIRCULATION MONITORCobe Renal Care, Inc.Feb 6, 1997SESE
K953875CRIT-LINE HEMATOCRIT ALERT (MODIFICATION)In-Line Diagnostics Corp.Jul 23, 1996SESE
K941460FRESENIUS BLOOD TEMPERATURE MONITORFresenius USA, Inc.Jul 3, 1996SESE
K953551KNOW-RECIRCH&H Control SystemsJun 21, 1996SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...