FKQ · System, Dialysate Delivery, Central Multiple Patient

Gastroenterology, Urology · 21 CFR 876.5820 · Class 2

Overview

Product CodeFKQ
Device NameSystem, Dialysate Delivery, Central Multiple Patient
Regulation21 CFR 876.5820
Device ClassClass 2
Review PanelGastroenterology, Urology
Life-SustainingYes

Identification

A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer.(1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air foam or bubble detectors, and alarms to keep blood moving safely from the blood access device and accessories for hemodialysis (§ 876.5540) to the blood compartment of the dialyzer and back to the patient. (2) The conventional dialyzer allows a transfer of water and solutes between the blood and the dialysate through the semipermeable membrane. The semipermeable membrane of the conventional dialyzer has a sufficiently low permeability to water that an ultrafiltration controller is not required to prevent excessive loss of water from the patient's blood. This conventional dialyzer does not include hemodialyzers with the disposable inserts (Kiil type) (§ 876.5830) or dialyzers of high permeability (§ 876.5860). (3) The dialysate delivery system consists of mechanisms that monitor and control the temperature, conductivity, flow rate, and pressure of the dialysate and circulates dialysate through the dialysate compartment of the dialyzer. The dialysate delivery system includes the dialysate concentrate for hemodialysis (liquid or powder) and alarms to indicate abnormal dialysate conditions. This dialysate delivery system does not include the sorbent regenerated dialysate delivery system for hemodialysis (§ 876.5600), the dialysate delivery system of the peritoneal dialysis system and accessories (§ 876.5630), or the controlled dialysate delivery system of the high permeability hemodialysis system § 876.5860). (4) Remote accessories to the hemodialysis system include the unpowered dialysis chair without a scale, the powered dialysis chair without a scale, the dialyzer holder set, dialysis tie gun and ties, and hemodialysis start/stop tray.

Classification Rationale

(1) Class II (performance standards) for hemodialysis systems and all accessories directly associated with the extracorporeal blood system and the dialysate delivery system.(2) Class I for other accessories of the hemodialysis system remote from the extracorporeal blood system and the dialysate delivery system, such as the unpowered dialysis chair, hemodialysis start/stop tray, dialyzer holder set, and dialysis tie gun and ties. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.

Recent Cleared Devices (20 of 61)

Showing 20 most recent of 61 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K052764DIACAP ULTRA DIALYSIS FLUID FILTERB. Braun Medizintechnologie GmbHJun 9, 2006SESE
K893612TWO TANK DISSOLUTION MODULENational Medical Care, Medical Products Div., Inc.Jul 24, 1989SESE
K874084MULTIPLE ARTIFICIAL KIDNEY SYSTEMS (MAKS) #IDMNational Medical Care, Medical Products Div., Inc.Apr 27, 1988SESE
K873421KAWASUMI A.V. FISTULA SETKawasumi Laboratories Co., Ltd.Oct 9, 1987SESE
K870889ACID FUCHSIN SOLUTIONSD.R.G. Scientific IndustriesJul 8, 1987SESE
K861730ACTRIL FOR KIDNEY MACHINE DISINFECTANTRenal Systems, Inc.Jun 9, 1987SESE
K864635FOUR TANK DISSOLUTION MODULENational Medical Care, Medical Products Div., Inc.Jan 13, 1987SESE
K862304DRAKE WILLOCK CENTRAL DIALYSATE DELIVERY SYSTEMCd Medical, Inc.Sep 9, 1986SESE
K861472MAKS CENTRAL DELIVERY SYSTEMS MODELS 11-425/11-445National Medical Care, Medical Products Div., Inc.Jul 10, 1986SESE
K852359AMUCHINA/DIALYZER DISINFECTANTAmuchina Intl., Inc.May 13, 1986SESE
K860336HEMODIALYSIS CONCENTRATES AND RELATED PRODUCTSBreem LaboratoriesMar 4, 1986SESE
K860297HEMODIALYSIS CONCENTRATE FORMULATIONS/ADDITIVESRenal HygienicsMar 4, 1986SESE
K860296HEMODIALYSIS CONCENTRATE FORMULATIONS/ADDITIVESPhysicians Surgeons Purchasing GroupMar 4, 1986SESE
K854391HEMODIALYSIS CONCENTRATEDana LaboratoriesJan 8, 1986SESE
K852749RECOMMENDED ALTERNATIVE DIALYZER DISINFECTANTMesa Medical, Inc.Sep 10, 1985SESE
K852310NATURALYTE BICARBONATE CONCENTRATE-DRY PACKErika, Inc.Jul 26, 1985SESE
K844734ALCIDE REN NEW-DAlcide Corp.May 17, 1985SESE
K844850MEDICORP DEHYDRACON A DEHYDRATED DIALYSATE CONCENTMedicorp, Inc.Apr 2, 1985SESE
K844750FRESENIUS A2008 HEMODIALYSIS MACHINE EXPANSION MODSeratronics, Inc.Feb 15, 1985SESE
K844641FRESENIUS HAEMODIALYSIS ;MACHINE A1008Seratronics, Inc.Feb 14, 1985SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...