FJK · Set, Tubing, Blood, With And Without Anti-Regurgitation Valve

Gastroenterology, Urology · 21 CFR 876.5820 · Class 2

Overview

Product CodeFJK
Device NameSet, Tubing, Blood, With And Without Anti-Regurgitation Valve
Regulation21 CFR 876.5820
Device ClassClass 2
Review PanelGastroenterology, Urology
Life-SustainingYes

Identification

A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer.(1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air foam or bubble detectors, and alarms to keep blood moving safely from the blood access device and accessories for hemodialysis (§ 876.5540) to the blood compartment of the dialyzer and back to the patient. (2) The conventional dialyzer allows a transfer of water and solutes between the blood and the dialysate through the semipermeable membrane. The semipermeable membrane of the conventional dialyzer has a sufficiently low permeability to water that an ultrafiltration controller is not required to prevent excessive loss of water from the patient's blood. This conventional dialyzer does not include hemodialyzers with the disposable inserts (Kiil type) (§ 876.5830) or dialyzers of high permeability (§ 876.5860). (3) The dialysate delivery system consists of mechanisms that monitor and control the temperature, conductivity, flow rate, and pressure of the dialysate and circulates dialysate through the dialysate compartment of the dialyzer. The dialysate delivery system includes the dialysate concentrate for hemodialysis (liquid or powder) and alarms to indicate abnormal dialysate conditions. This dialysate delivery system does not include the sorbent regenerated dialysate delivery system for hemodialysis (§ 876.5600), the dialysate delivery system of the peritoneal dialysis system and accessories (§ 876.5630), or the controlled dialysate delivery system of the high permeability hemodialysis system § 876.5860). (4) Remote accessories to the hemodialysis system include the unpowered dialysis chair without a scale, the powered dialysis chair without a scale, the dialyzer holder set, dialysis tie gun and ties, and hemodialysis start/stop tray.

Classification Rationale

(1) Class II (performance standards) for hemodialysis systems and all accessories directly associated with the extracorporeal blood system and the dialysate delivery system.(2) Class I for other accessories of the hemodialysis system remote from the extracorporeal blood system and the dialysate delivery system, such as the unpowered dialysis chair, hemodialysis start/stop tray, dialyzer holder set, and dialysis tie gun and ties. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.

Recent Cleared Devices (20 of 76)

Showing 20 most recent of 76 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K251341VITAL Tubing Sets for HemodialysisVital Healthcare Sdn. Bhd.Jan 16, 2026SESE
K251442TIANYI Extracorporeal Blood Tubing Set (TY-NDEO-A1)Ningbo Tianyi Medical Appliance Co., Ltd.Oct 2, 2025SESE
K243607Moda-flx Hemodialysis System™ Cartridge (102121-001 )Diality, Inc.Dec 20, 2024SESE
K213992CombiSet Hemodialysis Blood Tubing SetFresenius Medical Care Renal Therapies Group, LLCMay 31, 2023SESE
K210782Tablo CartridgeOutset Medical, Inc.Nov 26, 2021SESE
K202796SANSIN Tubing Sets for HemodialysisJiangxi Sanxin Medtec Co., Ltd.Sep 6, 2021SESE
K201866NovaLine Tubing Sets for HemodialysisBain Medical Equipment (Guangzhou) Co., Ltd.Mar 10, 2021SESE
K171952Dimesol Tubing Sets for HemodialysisDimesol, Inc.Mar 30, 2018SESE
K161582DORA Tubing Sets for HemodialysisBain Medical Equipment (Guangzhou) Co., Ltd.Jun 16, 2017SESE
K150304Oxyless Blood Tubing SetOxyless, Ltd.Feb 24, 2016SESE
K140841TABLO CARTRIDGEHome Dialysis PlusSep 11, 2014SESE
K112628NIPRO BLOOD TUBING SET WITH TRANSDUCER PROTECTOR AND PRIMING SETNipro Medical CorporationSep 28, 2012SESE
K120823BVM HEMODIALYSIS BLOOD TUBING SET WITH ATTACHED PRIMING SET AND TRANSDUCER PROTECTORSFresenius Medical Care North America, Design CenteJun 15, 2012SESE
K100364GAMBRO CARTRIDGE BLOOD SET LOW WEIGHT- LOW VOLUME, MODEL 003422-520Gambro Renal Products, Inc.Nov 3, 2010SESE
K090255BLOOD TUBING SETS (STERILE FLUID PATH)Nxstage Medical, Inc.Feb 10, 2009SESE
K080807BLOOD TUBING SETS (STERILE FLUID PATH)Nxstage Medical, Inc.Jul 18, 2008SESE
K070414GAMBRO CARTRIDGE BLOOD SETSGambro Renal ProductsOct 12, 2007SESE
K072024NIPRO BLOOD TUBING SET WITH TRANSDUCER PROTECTOR AND PRIMING SET, MODEL A201-A219, V801-V806, 5M9634, 5M9693Nipro Medical Corp.Oct 4, 2007SESE
K063293EDWARDS AQUALINE STERILE TUBING SET; EDWARDS AQUALINS STERILE TUBING SET; EDWARDS AQUASPIKE AND AQUASAFEEdwards Lifesciences Services GmbHMar 23, 2007SESE
K063290GAMBRO QUICKSET BLOODLINESGambro Renal ProductsJan 30, 2007SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...