FJG · Dialyzer, Parallel Flow

Gastroenterology, Urology · 21 CFR 876.5820 · Class 2

Overview

Product CodeFJG
Device NameDialyzer, Parallel Flow
Regulation21 CFR 876.5820
Device ClassClass 2
Review PanelGastroenterology, Urology
Life-SustainingYes

Identification

A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer.(1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air foam or bubble detectors, and alarms to keep blood moving safely from the blood access device and accessories for hemodialysis (§ 876.5540) to the blood compartment of the dialyzer and back to the patient. (2) The conventional dialyzer allows a transfer of water and solutes between the blood and the dialysate through the semipermeable membrane. The semipermeable membrane of the conventional dialyzer has a sufficiently low permeability to water that an ultrafiltration controller is not required to prevent excessive loss of water from the patient's blood. This conventional dialyzer does not include hemodialyzers with the disposable inserts (Kiil type) (§ 876.5830) or dialyzers of high permeability (§ 876.5860). (3) The dialysate delivery system consists of mechanisms that monitor and control the temperature, conductivity, flow rate, and pressure of the dialysate and circulates dialysate through the dialysate compartment of the dialyzer. The dialysate delivery system includes the dialysate concentrate for hemodialysis (liquid or powder) and alarms to indicate abnormal dialysate conditions. This dialysate delivery system does not include the sorbent regenerated dialysate delivery system for hemodialysis (§ 876.5600), the dialysate delivery system of the peritoneal dialysis system and accessories (§ 876.5630), or the controlled dialysate delivery system of the high permeability hemodialysis system § 876.5860). (4) Remote accessories to the hemodialysis system include the unpowered dialysis chair without a scale, the powered dialysis chair without a scale, the dialyzer holder set, dialysis tie gun and ties, and hemodialysis start/stop tray.

Classification Rationale

(1) Class II (performance standards) for hemodialysis systems and all accessories directly associated with the extracorporeal blood system and the dialysate delivery system.(2) Class I for other accessories of the hemodialysis system remote from the extracorporeal blood system and the dialysate delivery system, such as the unpowered dialysis chair, hemodialysis start/stop tray, dialyzer holder set, and dialysis tie gun and ties. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.

Recent Cleared Devices (20 of 36)

Showing 20 most recent of 36 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K933681GAMBRO LUNDIA PRO 100, 500, 600 DIALYZERSCobe Renal Care, Inc.Sep 7, 1994SESE
K933680GAMBRO LUNDIA PRO 200 DIALYZERCobe Renal Care, Inc.Aug 26, 1994SESE
K920693DEXTROLYTE II PERITONEAL DIALYSIS 48-3028-9National Medical Care, Medical Products Div., Inc.Sep 21, 1992SESE
K915504GAMBRO LUNDIA ALPHA HEMODIALYZERSC.G.H. Medical, Inc.Mar 6, 1992SESE
K901368HEMOSPAL KITS A1, A2D, AO, & A1DGambro-Hospal, Inc.Aug 2, 1990SESE
K902203TENCKHOFF PERITONEAL DIALYSIS KITAkcess Medical Products, Inc.Aug 1, 1990SESK
K862840GAMBRO LUNDIA 10-1L, 1N, 1H, 3H, 4N, 4H, 5H, 6NGambro, Inc.Sep 29, 1986SESE
K853406GAMBRO LUNDIA PRO 3 & 5 DIALYZERGambro, Inc.Jan 8, 1986SESE
K820694COBE PPD 1.3L, #18-520-009Cobe Laboratories, Inc.Mar 31, 1982SESE
K812336COBE PPD 1.9Cobe Laboratories, Inc.Aug 31, 1981SESE
K811440EXP 600 PARALLEL PLATE DIALYZERExtracorporeal Medical Specialities, Inc.Jun 12, 1981SESE
K811439EXP 200 PARALLEL PLATE DIALYZERExtracorporeal Medical Specialities, Inc.Jun 12, 1981SESE
K810066COBE PPD .8Cobe Laboratories, Inc.Jun 9, 1981SESE
K810837CYBER 80 HEMODIALYZERCyberex Corp.May 5, 1981SESE
K802478CYBER 120 HEMODIALYZERCyberex Corp.Mar 20, 1981SESE
K803068NIKKISO ND-14 PARALLEL FLOW DIALYZERNIKKISO CO., LTD.Mar 4, 1981SESE
K802364EXTRACORPOREAL'S EXP 400 PARALLEL PLATEExtracorporeal Medical Specialities, Inc.Jan 29, 1981SESE
K802389GAMBRO LUNDIA PLATE DISP. DIALYZERGambro, Inc.Dec 22, 1980SESE
K801633THE BRAVO NEW PARALLEL FLOW DIALYZERBellco Artifidial Organ Spec., Inc.Dec 18, 1980SESE
K801451ISONEPHROS-PEDIATRIC, STANDARD, OPTIMUMMedical, Inc.Sep 26, 1980SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...