510(k) Data Aggregation

    K Number
    K233208

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-01-24

    (118 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    NobelProcera® Titanium ASC Abutments:

    NobelProcera® Abutment Titanium is a patient-matched CAD/CAM prosthetic component directly connected to endosseous dental implants and is indicated for use as an aid in prosthetic rehabilitation.

    Omnigrip Clinical Screw Titanium:

    Clinical and Abutment Screws are indicated for use to secure a dental abutment or framework to a dental implant in the maxilla or mandible for supporting tooth replacements and are indicated as an aid in prosthetic rehabilitation.

    Device Description

    The Subject Device NobelProcera® Titanium ASC Abutment is composed of two device lines: NobelProcera® Titanium ASC Abutment and the Clinical Screw Omnigrip Titanium.

    NobelProcera® Titanium ASC Abutment is a patient matched CAD/CAM dental prosthesis which is connected to the Nobel Biocare implants featuring an internal conical and/or internal tri-channel connection, is available in the platform sizes NP, RP WP and 6.0 (for internal tri-channel connection only) and is intended for use as an aid in prosthetic rehabilitation to restore chewing function and esthetic appearance.

    NobelProcera® Titanium ASC Abutments undergo patient matched customization at a Nobel Biocare production facility for the final, finished abutment device manufacturing.

    NobelProcera® Titanium ASC Abutment is connected to the implant with a clinical screw and features an angulated screw channel which can be defined by the customer in an angulation (to the implant's axis) between 0° and 25°, in addition the abutment can be angulated to a maximum of 30°. The clinical screw features the Omnigrip Interface which allows tightening up to 25°.

    NobelProcera® Titanium ASC Abutment and Omnigrip Clinical Screw Titanium are composed of titanium vanadium alloy Ti6Al4V ELI (ISO 5832-3, ASTM F136) and the surface of the abutments are provided with and without anodization and the Omnigrip Clinical Screw Titanium are provided with and without DLC coating.

    The finished NobelProcera® Titanium ASC Abutment supports the placement of a cement-retained dental prosthesis.

    Omnigrip Clinical Screw Titanium is available for the NP, RP, WP and 6.0 (for internal tri-channel connection only) platform, the devices connect the NobelProcera Titanium ASC Abutments to the dental implants. The devices feature an Omnigrip interface.

    AI/ML Overview

    Here's an analysis of the provided text regarding acceptance criteria and device performance.

    Important Note: The provided document is an FDA 510(k) Premarket Notification letter. This type of document is a submission seeking regulatory clearance, not a standalone study report. As such, it outlines the basis for demonstrating substantial equivalence to a predicate device, which includes non-clinical testing. It does not typically contain detailed acceptance criteria and performance data for a study proving a device meets those criteria in the way a clinical trial report or a comprehensive validation study would.

    The document primarily focuses on demonstrating that the new device is substantially equivalent to legally marketed predicate devices, meaning it is as safe and effective. It refers to non-clinical tests that were performed, but does not present the specific acceptance criteria or the numerical results of those tests in a "performance table" format.

    Therefore, many of the requested points below cannot be fully extracted from this document, as it's not the type of report that contains that level of detail for acceptance criteria and specific study outcomes. I will highlight what can be inferred or directly stated from the provided text, and what cannot.


    1. A table of acceptance criteria and the reported device performance

    The document does not explicitly present a table of "acceptance criteria" alongside "reported device performance" in a quantitative manner as one might find in a detailed engineering validation report or a clinical study. Instead, it states that "non-clinical tests demonstrate that the device is substantial equivalent."

    The document mentions several tests and standards the device was subjected to:

    • Packaging system performance testing: per ASTM D4169. (Specific acceptance criteria and reported performance not detailed.)
    • Dynamic loading testing: conducted according to ISO 14801 and FDA Guidance Document ("Class II Special Controls Guidance Document: Root-form Endosseous Dental Implants and Endosseous Dental Abutments" (May 12, 2004)). (Specific acceptance criteria and reported performance not detailed.)
    • Magnetic Resonance compatibility testing: according to ASTM F2052, ASTM F2213, ASTM F2119, and ASTM F2182. Status: "MR Conditional." (This is a performance outcome, but the specific metrics and acceptance thresholds for each ASTM standard are not detailed.)
    • Verification of biocompatibility: in accordance with ISO 10993-1. (The conclusion is that "no new issues regarding biocompatibility were raised," implying acceptance, but specific criteria and test results not detailed.)
    • End user cleaning and sterilization validation: in accordance with ISO 17665-1. (Implied acceptance, but specific criteria and results not detailed.)

    The "acceptance criteria" here are generally referred to as meeting the requirements of the standards and demonstrating substantial equivalence to the predicate device. The "reported device performance" is summarized as favorable results sufficient for substantial equivalence determination.

    2. Sample sizes used for the test set and the data provenance

    • Sample sizes: Not specified in the provided text for any of the non-clinical tests mentioned (packaging, dynamic loading, MR compatibility, biocompatibility, sterilization validation).
    • Data provenance: Not explicitly stated (e.g., country of origin). The testing is non-clinical/bench testing, not patient data. It is implied to be internal testing by the manufacturer, Nobel Biocare AB (Sweden).
    • Retrospective or prospective: N/A, as these are non-clinical/bench tests, not clinical studies involving patient data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • Applicability: This question is not directly applicable to the type of non-clinical, bench testing described for the NobelProcera® Titanium ASC Abutment and Omnigrip Clinical Screw Titanium. "Ground truth" established by experts (e.g., radiologists for image interpretation) is relevant for AI/ML device evaluations, particularly in diagnostics. This document refers to physical device testing (mechanical, biocompatibility, etc.).

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Applicability: Not applicable. Adjudication methods are typically used in clinical studies or expert reviews to resolve disagreements in interpretations or diagnoses for establishing "ground truth," which is not the nature of the non-clinical tests described here.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • Applicability: Not applicable. This device is a dental abutment and screw, not an AI/ML-enabled diagnostic device for image interpretation. Therefore, no MRMC study or AI assistance evaluation would have been performed.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Applicability: Not applicable. See point 5. This is a physical medical device, not a standalone algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • Applicability: The concept of "ground truth" as typically applied in AI/ML validation (e.g., for diagnostic accuracy) does not directly apply to the non-clinical device testing described. For these tests, the "ground truth" is typically defined by the specified parameters and performance requirements of the relevant international standards (e.g., ISO 14801 for dynamic loading, ISO 10993-1 for biocompatibility). The devices are expected to meet the performance criteria defined by these standards.

    8. The sample size for the training set

    • Applicability: Not applicable. This refers to the training of an AI/ML algorithm. The document describes a physical medical device.

    9. How the ground truth for the training set was established

    • Applicability: Not applicable. See point 8.
    Ask a Question

    Ask a specific question about this device

    K Number
    K220339

    Validate with FDA (Live)

    Date Cleared
    2022-09-16

    (221 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K211109, K212125

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Esthetic Abutment Nobel Biocare N1™ TCC: The Esthetic Abutment Nobel Biocare N1™ TCC is a pre-manufactured component directly connected to an endosseous dental implant and is indicated for use as an aid in single unit prosthetic rehabilitation. Esthetic Abutment Nobel Biocare N1TM Base: The Esthetic Abutment Nobel Biocare N1™ Base is a pre-manufactured component connected to an endosseous dental implant and is indicated for use as an aid in single unit prosthetic rehabilitation.

    Device Description

    Esthetic Abutments Nobel Biocare N1™ are pre-manufactured dental implant abutments, intended for use as an aid in prosthetic rehabilitation. Esthetic Abutments Nobel Biocare N1™ are intended for use in the upper and/or lower jaw in combination with Nobel Biocare's Nobel Biocare N1™ implant system in order to restore patient esthetics and chewing function to partially or fully edentulous patients. The abutments are made from titanium vanadium allov. Esthetic Abutments Nobel Biocare N1 ™ is composed of two device lines: Esthetic Abutment Nobel Biocare N1™ TCC and Esthetic Abutment Nobel Biocare N1™ Base.

    AI/ML Overview

    The acceptance criteria and device performance for the Nobel Biocare N1™ Esthetic Abutments are described based on the provided FDA 510(k) summary.

    1. Table of Acceptance Criteria and Reported Device Performance

    Performance MetricAcceptance Criteria (Standard / Guidance)Reported Device Performance
    Mechanical Strength (Fatigue)ISO 14801 and FDA Guidance Document: "Class II Special Controls Guidance Document: Root-form Endosseous Dental Implants and Endosseous Dental Abutments" (May 12, 2004)The tests demonstrated the Subject Devices are substantially equivalent to the Primary Predicate Device and Reference Device #1 (for TCC abutments) and to Predicate Device #2 and Reference Device #1 (for Base abutments). The Subject Device met the performance specifications.
    Magnetic Resonance (MR) CompatibilityASTM F2052, ASTM F2213, ASTM F2119, ASTM F2182MR Conditional
    BiocompatibilityISO 10993-1:2018 Biological Evaluation of Medical DevicesBiocompatible
    Cleaning and SterilizationISO 17665-1 and AAMI TIR12Validation performed

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not explicitly state the specific sample sizes for each test. However, it mentions that dynamic loading (fatigue) testing was conducted in saline at 37 °C. The data provenance is from non-clinical testing, therefore not involving human subjects or data from a specific country of origin in the context of clinical studies. The testing was performed in a laboratory setting.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Their Qualifications

    Not applicable. The reported performance data for this device (dental abutments) is based on non-clinical, laboratory-based testing (mechanical, MRI compatibility, biocompatibility, cleaning/sterilization), rather than expert assessment of clinical data or images to establish a "ground truth."

    4. Adjudication Method for the Test Set

    Not applicable. As the testing mentioned is non-clinical and laboratory-based, an adjudication method in the context of human assessment is not relevant.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No, a multi-reader multi-case (MRMC) comparative effectiveness study was not done. The device is a physical dental abutment, not a diagnostic or AI-assisted interpretation system.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    Not applicable. This device is a physical dental abutment, not an algorithm or software. The performance evaluations are of the physical product's characteristics.

    7. The Type of Ground Truth Used

    The "ground truth" for the performance criteria is established by adherence to recognized international and FDA standards for medical device testing. For example:

    • Mechanical strength: Conformance to force/stress limits defined by ISO 14801.
    • MRI compatibility: Conformance to safety and performance specifications outlined in ASTM F2052, F2213, F2119, F2182.
    • Biocompatibility: Conformance to safety requirements defined by ISO 10993-1.

    8. The Sample Size for the Training Set

    Not applicable. This is a physical medical device, not an AI/ML algorithm that requires a training set.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable. This is a physical medical device, not an AI/ML algorithm.

    Ask a Question

    Ask a specific question about this device

    K Number
    K220048

    Validate with FDA (Live)

    Date Cleared
    2022-07-29

    (204 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K211109, K132746

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    · NobelProcera® Zirconia Abutment/Implant Crown N1™ Base:

    The NobelProcera® Zirconia Abutment/Implant Crown N1™ Base is a patient-matched CAD/CAM prosthetic component directly connected to an endosseous dental implant abutment with the Prosthetic Screw and is indicated for use as an aid in prosthetic rehabilitation.

    · Prosthetic Screw NobelProcera® Zr Nobel Biocare N1™ Base:

    The Prosthetic Screw is to be directly connected to the dental abutment or crown, indicated for use as an aid in prosthetic rehabilitation.

    Device Description

    NobelProcera® Zirconia N1™ Base (premanufactured and patient matched prosthetic components) is composed of two subject device lines:

    • NobelProcera® Zirconia Abutment / Implant Crown N1™ Base and -
    • -Prosthetic Screw NobelProcera® Zr Nobel Biocare N1™ Base

    The NobelProcera® Zirconia Abutment / Implant Crown N1™ Base is a patient-matched specific CAD/CAM dental prosthesis which is connected to dental implants via a titanium base adapter (Nobel Biocare N1™ Base Xeal™ TCC Tri) and is intended for use as an aid in prosthetic rehabilitation to restore chewing function and esthetic appearance. The NobelProcera® Zirconia Abutment / Implant Crown N1™ Base is available as device in two restorative design solutions as described following:

    a) The Abutment design is intended to mimic a prepared tooth which is then finalized with a restoration

    b) The Implant Crown design incorporates part or all of the final restoration (i.e. Crown) into its design

    The abutment / implant crowns are manufactured from zirconia (Yttria stabilized tetragonal zirconia according to ISO 13356) and are designed in a dental laboratory, hospital or dental practice by scanning, designing and ordering the restoration using dental CAD/CAM software and a Nobel Biocare/KaVo approved dental scanner. The NobelProcera® Zirconia Abutment/Implant Crown N1™ Base can be modeled with conventional impression, using a model to be scanned with a desktop scanner or directly with an intra oral scan with a Nobel Biocare/Kavo approved scanner. The finished design is sent to Nobel Biocare manufacturing facility for industrial production. After production, the abutment / implant crown is sent to the laboratory for finishing.

    NobelProcera® Zirconia Abutment / Implant Crown N1™ Base is provided with the required Prosthetic Screw, the Prosthetic Screw NobelProcera® Zr Nobel Biocare N1™ Base which is a pre-manufactured dental prosthetic screw used to fasten the NobelProcera® Zirconia Abutment / Implant Crown N1™ Base to a titanium base adapter (Nobel Biocare N1™ Base Xeal™ TCC Tri). The Prosthetic Screw NobelProcera® Zr Nobel Biocare N1 ™ Base is made of titanium alloy according to ASTM F136 / ISO 5832-3.

    The subject device lines are components of a two-piece abutment construct which consists of the Nobel Biocare N1™ Base Xeal™ TCC Tri (K211109) screw-retained using the Prosthetic Screw NobelProcera® Zr Nobel Biocare N1™ Base (subject device line) to the NobelProcera® Zirconia Abutment / Implant Crown N1™ (subject device line).

    AI/ML Overview

    The provided document is a 510(k) premarket notification for a dental device, specifically the NobelProcera® Zirconia N1™ Base and its associated Prosthetic Screw. The notification aims to demonstrate substantial equivalence to previously marketed predicate devices, rather than establishing de novo acceptance criteria or proving performance against novel criteria through clinical studies. Therefore, much of the requested information regarding a device meeting specific acceptance criteria and the nature of the study that proves it, as it would apply to a new classification or a device with new indications requiring extensive clinical validation, is not directly available or applicable in the provided context of a 510(k) submission for substantial equivalence.

    However, I can extract information related to the performance data used to support substantial equivalence, which serves a similar purpose to demonstrating acceptance criteria in this regulatory pathway. The acceptance criteria here are implicitly alignment with the performance of the predicate and reference devices.

    Here's a summary based on the provided text, addressing what can be inferred or directly stated:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not present explicit "acceptance criteria" in a quantitative table format that a device must meet to be considered "safe and effective." Instead, it focuses on demonstrating substantial equivalence by comparing its characteristics and performance to legally marketed predicate and reference devices. The "reported device performance" is primarily comparative in nature.

    Implicit Acceptance Criteria (Demonstrated Equivalence) & Reported Performance:

    CategoryImplicit Acceptance Criteria (Comparative)Reported Device Performance (Summary from Submission)
    Indications for UseSame as predicate/reference devices.NobelProcera® Zirconia Abutment / Implant Crown N1™ Base: Same as Primary Predicate (On1 Concept - K161655), expressed through similar wording. Prosthetic Screw NobelProcera® Zr Nobel Biocare N1™ Base: Same as Reference Device No. 1 (Prosthetic Screw Nobel Biocare N1™ Base), expressed through similar wording.
    Technological CharacteristicsSimilar to predicate/reference devices, with any differences not raising new concerns.NobelProcera® Zirconia Abutment / Implant Crown N1™ Base: Device design, compatible Implant/Base platforms (NP/RP), device connection/connector, materials of the connector, screw access, and device attachment method are identical or similar to the Primary Predicate. Ceramic material is Y-TZP, similar to predicate, and specifically "Nacera Pearl" (K143071), which is also used in Reference Device No. 1. Design methods, ASC angulation (0°-25°), and dimensions are similar to Reference Device No. 2. Maximum device body angulation limits are similar to Reference Device No.1, with differences substantiated by fatigue testing. Prosthetic Screw NobelProcera® Zr Nobel Biocare N1™ Base: Principle of operation, compatible Implant/Base platforms (NP/RP), device material (Ti6Al4V ELI), thread design, and screw interfaces (Omnigrip Mini) are the same as Reference Device No. 1. DLC coating applied to screw body, similar to Reference Device No. 1. Differences in screw body dimensions, anodization (subject device is not anodized), and packaging do not raise new concerns.
    Performance (Non-clinical)Performance as good as predicate/reference devices for intended use, as demonstrated by recognized standards (e.g., ISO 14801, ISO 10993-1, ASTM).Fatigue Performance: Dynamic loading testing performed according to ISO 14801. Testing found acceptable, including evaluation of removal torque and no screw-loosening for run-out samples. Biocompatibility: Demonstrated according to ISO 10993-1. Wear Assessment: Light optical and SEM imaging following ISO 14801 fatigue loading showed similar wear patterns to reference device systems (NobelProcera® Zirconia Implant Bridge (K202452) and NobelProcera® ASC Abutment CC (K132746)). Packaging System Performance: Tested per ASTM D4169. Magnetic Resonance Compatibility: Tested according to ASTM F2052, ASTM F2213, ASTM F2119, and ASTM F2182. Cleaning and Sterilization Validation: End user cleaning and sterilization validation in accordance with ISO 17665-1 and AAMI TIR12.
    Performance (Clinical/Real-World Evidence)No evidence of new safety/effectiveness concerns with differences in materials or design.Post-Market Surveillance (PMS) Data: - NPr ASC Ab Zirconia CC (K132746): 8.1 years in patient, low complaint rates, no concerns regarding dissimilar materials (DLC-coated screw with Zirconia abutment). - NobelProcera® Zr Implant Bridge (K202452): 1.7 years in patient, low complaint rates, no concerns regarding dissimilar materials. Clinical Data: Five clinical studies on NPr ASC Ab Zirconia CC (K132746) with mean follow-ups of 0.6-3.6 years, reporting on 277 devices. No reports of wear debris from Zirconia/DLC-coated screw contact or other adverse events raising concerns about dissimilar materials. A gap analysis was provided to support the relevance and reliability of this real-world evidence.

    2. Sample Size for the Test Set and Data Provenance

    The document does not define a single "test set" in the context of a clinical trial for direct performance measurement. Instead, it refers to various non-clinical tests and real-world evidence.

    • Non-clinical testing (Fatigue, Wear, MRI Compatibility, Packaging): The sample sizes for these specific tests are not provided in the summary. For example, ISO 14801 fatigue testing typically involves a certain number of samples (e.g., n=10-12 per group) but this detail is omitted.
    • Real-World Evidence (PMS Data):
      • NPr ASC Ab Zirconia CC (K132746): Data collected from December 2013 up to January 2022. The longest time in a patient was approx. 8.1 years.
      • NobelProcera® Zr Implant Bridge (K202452): Data collected from May 2020 up to January 2022. The longest time in a patient was approx. 1.7 years.
      • Data Provenance: This is post-market surveillance data, likely originating from clinical use of the cleared predicate/reference devices, implicitly from various countries where Nobel Biocare products are marketed. It is retrospective in nature.
    • Clinical Data (NPr ASC Ab Zirconia CC):
      • Sample Size: 277 NPr ASC Ab Zirconia CC (K132746) devices were reported across 5 clinical studies.
      • Data Provenance: The document states the studies were "included consecutively with no selection regarding study inclusion made besides the inclusion criterion that the NPr ASC Ab Zirconia CC had to be used in the study." The studies were published in international journals, suggesting prospective clinical studies from potentially diverse geographical origins, but specific countries are not mentioned (e.g., "[1] Greer, A.C., et al., Int J Prosthodont, 2017"). These are considered Real World Evidence in this submission.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications

    This specific information is not provided in the document. For 510(k) submissions focusing on substantial equivalence, the "ground truth" for the test set is usually the performance of the predicate device as established by its clearance and recognized standards, rather than a new expert consensus process for the subject device. The clinical studies mentioned were about observing device performance in patients, not establishing a new ground truth.


    4. Adjudication Method for the Test Set

    This information is not provided in the document. Adjudication methods like 2+1 or 3+1 are typical for interpreting subjective endpoints in clinical trials or for establishing ground truth from multiple expert readings (e.g., in AI/imaging studies). The provided clinical evidence references published studies with their own methodologies, which are not detailed here.


    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study was done

    No, an MRMC comparative effectiveness study was not done. The studies cited are focused on the clinical performance and safety of existing devices (predicates/references) and a "gap analysis" for using that as real-world evidence for the subject device, or non-clinical engineering tests. There is no mention of comparing human readers with and without AI assistance.


    6. If a Standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This question is not applicable as the device is a physical dental abutment and prosthetic screw, not an AI algorithm or software. Therefore, there is no "standalone" performance in the context of an algorithm.


    7. The Type of Ground Truth Used

    The "ground truth" for demonstrating substantial equivalence is primarily:

    • Engineering Standards: Compliance with ISO 14801, ISO 10993-1, ASTM F2052, F2213, F2119, F2182, ISO 17665-1, AAMI TIR12.
    • Predicate Device Performance: The established safety and effectiveness of the legally marketed predicate and reference devices (On1 Concept K161655, N1™ TiUltra™ TCC Implant system K211109, NobelProcera Angulated Screw Channel Abutment Conical Connection K132746, Nacera Pearl K143071).
    • Outcomes Data/Real-World Evidence: Post-market surveillance data and clinical study outcomes for the predicate/reference devices, showing low complaint rates, good tissue health, and no unexpected adverse events related to material interactions. These outcomes serve as a proxy for acceptable performance.

    8. The Sample Size for the Training Set

    This concept is not applicable as the device is a physical dental component and not an AI/machine learning model that undergoes a "training" phase with a dataset.


    9. How the Ground Truth for the Training Set was Established

    This question is not applicable for the same reason as point 8.

    Ask a Question

    Ask a specific question about this device

    K Number
    K221019

    Validate with FDA (Live)

    Date Cleared
    2022-07-05

    (90 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Predicate For
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Osteon Precision Milled Suprastructure is indicated for attachment to dental abutments in the treatment of partially or fully edentulous jaws for the purpose of restoring function. The Osteon Precision Milled Suprastructures are intended for attachment to a minimum of two (2) abutments.

    The Osteon Milled Suprastructure is indicated for compatibility with the following abutment systems:

    • Astra Tech Implant System® Multi Base Abutment EV, 4.8 mm, max 30°
    • DESS Dental Multi Unit Abutments, 3.4-5.7 mm, 0°
    • 3i OSSEOTITE®
    • Astra Tech OsseoSpeed™
    • Neodent Grand Morse
    • NobelReplace® Conical
    • NobelReplace® Trilobe
    • Nobel Brånemark System®
    • Straumann BLX Implants
    • DESS Dental Multi Unit Abutments, Angled, 3.4-6.5 mm, max 30°
    • NobelActive® NobelParallel Conical
    • Straumann® Bone Level
    • Zimmer Screw Vent® and Tapered Screw-Vent®
    • Dentium SuperLine® Abutments, 4.5-5.5 mm, max 30°
    • Keystone Multi Unit Abutment, 4.8 mm, 0°
    • Implant Direct GPS® Angled Abutment, 5.0 mm, max 30°
    • MIS Multi-unit Abutments, 4.8 mm
    • C1 Conical Connection Implant System, max 30°
    • V3 Conical Connection Implant System, max 30°
    • Internal Hex Implant System, max 30°
    • Conical Connection, max 30°
    • Neodent GM Mini Conical Abutment, 4.8 mm, max 30°
    • Nobel Biocare Brånemark Multi-Unit Abutment, 4.8 mm, max 17°
    • Nobel Biocare Multi-Unit Abutment Plus, 4.8 mm, max 30°
    • Nobel Biocare Multi-Unit Abutment, 4.8 mm, max 30°
    • Nobel Biocare Multi-Unit Abutments for Straumann and Astra Tech System, 4.8mm, max 30°
    • Nobel Biocare Multi-Unit Abutments for Astra Tech, Camlog and Ankylos Implant Systems, 4.8 mm, max 30°
    • Nobel Biocare Xeal Abutments, 4.8 mm, max 30°
    • Paltop Multi Unit Abutment, 5.0 mm, max 17°
    • Southern Compact Conical Abutments, 4.8 mm
    • MAX Implant System, 0°
    • Provata Implant System, max 30°
    • Deep Conical (DC) Implants, 0°
    • Piccolo Implants, 0°
    • External Hex Implants, max 30°
    • Straumann® BLX Screw Retained Abutment, 4.6 mm, max 30°
    • Straumann® Screw Retained Abutment, 4.6 mm, max 30°
    • Zimmer Angled Tapered Abutments, 4.5 mm, max 30°
    Device Description

    The Osteon Precision Milled Suprastructures (also referred to as superstructures) are metallic dental restorative devices that are intended to be attached by screw retention to dental implant abutments to aid in the treatment of partial and totally edentulous patients for the purpose of restoring function. These suprastructures attach to dental implant abutments using the prosthetic screws from the original equipment manufacturers (OEM) and are used to support the final multi-unit restoration.

    The Osteon Precision Milled Suprastructure is designed for an individual patient from scans of the patient's dental impression. The suprastructure is manufactured with the aid of Computer Aided Design (CAD) and Computer Aided Manufacturing (CAM) technology. All CAD/CAM fabrication is performed by Osteon Medical.

    Osteon Precision Milled Suprastructures facilitate the attachment of both removable and fixed dental prosthesis and hence are categorized as Type A and Type B.

    • Type A: Intended to act as a supporting structure to facilitate the attachment of removable dental prosthesis and include Primary Bar and Nexus Removable Bar.
    • Type B: Intended to act as a supporting structure to facilitate the attachment of fixed dental prosthesis and include Melbourne Bar and Nexus Fixed Bar
    AI/ML Overview

    N/A