K Number
K121342

Validate with FDA (Live)

Manufacturer
Date Cleared
2012-06-22

(49 days)

Product Code
Regulation Number
888.3070
Age Range
All
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

The XIA® 4.5 Spinal System is intended for anterior/anteriolateral and posterior, noncervical pedicle and non-pedicle fixation for the following indications:

  • Degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies);
  • Spondylolisthesis:
  • Trauma (i.e. fracture or dislocation);
  • Spinal stenosis;
  • Curvatures (i.e. scoliosis, kyphosis, and/or lordosis);
  • Tumor;
  • Pseudoarthrosis: and
  • Failed previous fusion.

The Stryker Spine DIAPASON™ Spinal System, OPUS™ Spinal System and XIA® 4.5 Spinal System can be linked to the XIA® 4.5 Spinal System via the rod-to-rod connector.

When used for posterior noncervical pedicle screw fixation in pediatric patients, the XIA 4.5 Spinal System implants are indicated as an adjunct to fusion to treat adolescent idiopathic scoliosis. The XIA 4.5 Spinal System for pediatric use is intended to be used with autograft and/or allografi. Pediatric pedicle screw fixation is limited to a posterior approach.

Device Description

The XIA® 4.5 Spinal System consists of a variety of titanium Monoaxial & Polyaxial Bone Screws, Monoaxial & Polyaxial Reduction Screws, Hooks, Blockers, Rod Connectors, Dual Staples and Connectors. The existing components of the XIA 4.5 Spinal System were determined substantially equivalent through K050461 for class II indications consistent with 21 CFR 888.3070 (b) (1). The indications were expanded through K060361 to include class III indications per product code NKB, 21 CFR 888.3070 (b) (2). Subsequent line extensions have been cleared through K060748, and K092605.

The expansion of indications for the XIA 4.5 Spinal System is proposed for the inclusion of adolescent idiopathic scoliosis alone, and not other indications for a pediation. As pediatric patients are unlikely to exhibit symptoms of degenerative disc disease (DDD) or stenosis due to the wear and tear on the spine necessary to develop these diseases, expansion of these indications to a pediation is not warranted.

AI/ML Overview

This document (K121342) is a 510(k) premarket notification for the Stryker XIA® 4.5 Spinal System, seeking clearance for expanded indications, specifically for adolescent idiopathic scoliosis.

The acceptance criteria and study information indicate that the device's substantial equivalence relies on biomechanical testing and a clinical literature analysis, not on a clinical ground truth study as typically seen for AI/ML devices. Therefore, many of the requested fields are not applicable.

Here's the information based on the provided text:

1. Table of Acceptance Criteria and Reported Device Performance

Acceptance CriteriaReported Device Performance
Static compression bending (per ASTM F1717)Substantially Equivalent: Testing demonstrated equivalence to predicate devices.
Dynamic compression bending (per ASTM F1717)Substantially Equivalent: Testing demonstrated equivalence to predicate devices.
Static torsion testing (per ASTM F1717)Substantially Equivalent: Testing demonstrated equivalence to predicate devices.
Interconnection strength testing (per ASTM F1798)Substantially Equivalent: Testing demonstrated equivalence to predicate devices.
Clinical Literature AnalysisSubstantially Equivalent: Analysis supported equivalence to predicate devices.
Dimensional ComparisonsSubstantially Equivalent: Comparisons supported equivalence to predicate devices.
Engineering AnalysesSubstantially Equivalent: Analyses supported equivalence to predicate devices.

2. Sample size used for the test set and the data provenance

  • Sample Size: Not applicable. The submission relies on biomechanical testing and literature review rather than a clinical test set in the context of an AI/ML device.
  • Data Provenance: Not applicable for a clinical test set. Biomechanical testing would have been conducted in a lab environment.

3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

  • Number of Experts: Not applicable. Ground truth from experts is not mentioned for this type of submission.
  • Qualifications of Experts: Not applicable.

4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

  • Adjudication Method: Not applicable. There is no clinical test set requiring adjudication in this submission.

5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

  • MRMC Study: No. This is a spinal implant, not an AI/ML diagnostic or assistive device.

6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

  • Standalone Study: No. This product is a physical spinal implant, not an algorithm.

7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

  • Type of Ground Truth: For the biomechanical testing, the "ground truth" would be the established performance characteristics of the predicate devices and the relevant ASTM standards for spinal implants. For the clinical literature analysis, the literature itself serves as the basis for comparison. No clinical "ground truth" as in pathology or outcomes data from a prospective study of this device.

8. The sample size for the training set

  • Sample Size for Training Set: Not applicable. This is not an AI/ML device requiring a training set.

9. How the ground truth for the training set was established

  • Ground Truth Establishment for Training Set: Not applicable.

{0}------------------------------------------------

K121342 Page 1 of 3

510(K) SUMMARY

1.1 Applicant

Stryker Spine 2 Pearl Court. Allendale, NJ 07401 Phone: (201)-760-8206 Fax: (201)-760-8406 E-mail: tiffani.rogers@stryker.com

Contact Information:

Tiffani Rogers Regulatory Affairs Manager Stryker Spine Two Pearl Court Allendale, NJ 07401 Phone: (201)- 760-8206 Fax: (201)-760-8406 E-mail: tiffani.rogers@stryker.com

1.2 Device Trade Name:

XIA® 4.5 Spinal System

1.3 Device Common Name:

Spinal Fixation Appliances

1.4 Establishment Registration Number 3004024955

Manufacturer Address 1.5

Stryker Spine Zone Industrielle Demarticot Cestas, France 33610 Phone: + 33 577 97 08 40 Manufacturer Establishment Number: 9617544 JUN 2 2 2 2012

{1}------------------------------------------------

And

Stryker Spine Le Cret Du Locle 10a La Chaux De Fonds Switzerland 2300 Establishment Registration Number: 3005525032

1.6 Device Classification:

Primary Classification - Class: II Classification: 21 CFR 888.3070 (b) (1) & (b) (2) Classification Name: Pedicle Screw Spinal System

Additional Classification (K60361, K060979) - Class: II/III Classification: 21 CFR §888.3060 Classification Name: Pedicle Screw Spinal Intervertebral Body Fixation Orthosis

Additional Classification (K060748) - Class: II/III Classification: 21 CFR 888.3050 Classification Name: Pedicle Screw Spinal System, Spinal Interlaminal Fixation Orthosis

1.7 Device Product Codes: OSH, NKB, KWP, KWQ, MNH, MNI

Device Description/Modification: 1.8

The XIA® 4.5 Spinal System consists of a variety of titanium Monoaxial & Polyaxial Bone Screws, Monoaxial & Polyaxial Reduction Screws, Hooks, Blockers, Rod Connectors, Dual Staples and Connectors. The existing components of the XIA 4.5 Spinal System were determined substantially equivalent through K050461 for class II indications consistent with 21 CFR 888.3070 (b) (1). The indications were expanded through K060361 to include class III indications per product code NKB, 21 CFR 888.3070 (b) (2). Subsequent line extensions have been cleared through K060748, and K092605.

The expansion of indications for the XIA 4.5 Spinal System is proposed for the inclusion of adolescent idiopathic scoliosis alone, and not other indications for a pediation. As pediatric patients are unlikely to exhibit symptoms of degenerative disc disease (DDD) or stenosis due to the wear and tear on the spine necessary to develop these diseases, expansion of these indications to a pediation is not warranted.

{2}------------------------------------------------

1.9 Indications for Use

The XIA 4.5 Spinal System is intended for anterior/anteriolateral and posterior, noncervical pedicle and non-pedicle fixation for the following indications:

  • . Degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies);
  • I Spondvlolisthesis:
  • D Trauma (i.e. fracture or dislocation);
  • Spinal stenosis;
  • 미 Curvatures (i.e. scoliosis, kyphosis, and/or lordosis);
  • 미 Tumor;
  • Pseudoarthrosis: and
  • Failed previous fusion.

The Stryker Spine DIAPASON™ Spinal System, OPUS™ Spinal System and XIA® 4.5 Spinal System can be linked to the XIA® 4.5 Spinal System via the rod-to-rod connector.

When used for posterior noncervical pedicle screw fixation in pediatric patients, the XIA 4.5 Spinal System implants are indicated as an adjunct to fusion to treat adolescent idiopathic scoliosis. The XIA 4.5 Spinal System for pediatric use is intended to be used with autograft and/or allografi. Pediatric pedicle screw fixation is limited to a posterior approach.

Predicate Devices 1.10

Substantial Equivalence 1.11

Testing performed on this device that the XIA 4.5 Spinal System is substantially equivalent to predicate devices. Mechanical testing of the system included static and dynamic compression bending testing and static torsion testing per ASTM F1717and interconnection strength testing per ASTM F1798, as well as, a clinical literature analysis.

The XIA 4.5 Spinal System was shown to be substantially equivalent to previously cleared devices with respect to its indications for use, design, function, and materials.

The Xia 4.5 Spinal System substantial equivalence determination to the predicate systems is based on dimensional comparisons and engineering analyses in addition to preclinical testing.

{3}------------------------------------------------

Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features a stylized depiction of three human profiles facing right, arranged in a stacked formation. Above the profiles are three curved lines that appear to be flowing or waving. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the emblem.

Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002

June 27, 2013

Stryker Corporation % Ms. Tiffani Rogers Regulatory Affairs Manager 2 Pearl Court Allendale, New Jersey 07401

Re: K121342

Trade/Device Name: Xia 4.5 Spinal System Regulation Number: 21 CFR 888.3070 Regulation Name: Pedicle screw spinal system Regulatory Class: III Product Code: NKB, OSH, KWP, KWQ, MNH, MNI Dated: May 2, 2012 Received: May 4, 2012

Dear Ms. Rogers:

This letter corrects our substantially equivalent letter of June 22, 2012.

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. Iisting of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21

{4}------------------------------------------------

Page 2 - Ms. Tiffani Rogers

CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act): 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Small Manufacturers, International and Consumer Assistance at its tollfree number (800) 638 2041 or (301) 796-7100 or at its Internet address

http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to

http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.

Sincerely yours,

Image /page/4/Picture/7 description: The image shows the name "Erin DKeith" in a bold, sans-serif font. The letters "Erin" and "ith" are clear and easily readable. The letters "DKe" are stylized with overlapping lines and shapes, making them appear more abstract and decorative.

For

Mark N. Melkerson Director Division of Orthopedic Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{5}------------------------------------------------

INDICATIONS FOR USE STATEMENT

510(k) Number (if known): K121342

Device Name: XIA® 4.5 Spinal System

Indications for Use:

The XIA® 4.5 Spinal System is intended for anterior/anteriolateral and posterior, noncervical pedicle and non-pedicle fixation for the following indications:

  • 트 Degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies);
  • Spondylolisthesis: l
  • Trauma (i.e. fracture or dislocation); B
  • Spinal stenosis; I
  • Curvatures (i.e. scoliosis, kyphosis, and/or lordosis);
  • 1 Tumor;
  • . Pseudoarthrosis; and
  • Failed previous fusion. ●

The Stryker Spine DIAPASON™ Spinal System, OPUS™ Spinal System and XIA® 4.5 Spinal System can be linked to the XIA . 4.5 Spinal System via the rod-to-rod connector when used for the aforementioned indications in skeletally mature patients as an adjunct to fusion.

Except for the staples, the Xia 4.5 Spinal System .is indicated as an adjunct to fusion to treat adolescent idiopathic scoliosis when used for posterior noncervical pediation in pediatic patients. The XIA 4.5 Spinal System for pediatric use is intended to be used with autograft and/or allograft. Pediatric pedicle screw fixation is limited to a posterior approach.

Over-The-Counter Prescription Use Use AND/OR (21 CFR 801 Subpart C) (Part 21 CFR 801 Subpart D)

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

(Division Sign-Off) Division of Surgical, Orthopedic, and Restorative Devices

KI21342 510(k) Number.

§ 888.3070 Thoracolumbosacral pedicle screw system.

(a)
Identification. (1) Rigid pedicle screw systems are comprised of multiple components, made from a variety of materials that allow the surgeon to build an implant system to fit the patient's anatomical and physiological requirements. Such a spinal implant assembly consists of a combination of screws, longitudinal members (e.g., plates, rods including dual diameter rods, plate/rod combinations), transverse or cross connectors, and interconnection mechanisms (e.g., rod-to-rod connectors, offset connectors).(2) Semi-rigid systems are defined as systems that contain one or more of the following features (including but not limited to): Non-uniform longitudinal elements, or features that allow more motion or flexibility compared to rigid systems.
(b)
Classification. (1) Class II (special controls), when intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: severe spondylolisthesis (grades 3 and 4) of the L5-S1 vertebra; degenerative spondylolisthesis with objective evidence of neurologic impairment; fracture; dislocation; scoliosis; kyphosis; spinal tumor; and failed previous fusion (pseudarthrosis). These pedicle screw spinal systems must comply with the following special controls:(i) Compliance with material standards;
(ii) Compliance with mechanical testing standards;
(iii) Compliance with biocompatibility standards; and
(iv) Labeling that contains these two statements in addition to other appropriate labeling information:
“Warning: The safety and effectiveness of pedicle screw spinal systems have been established only for spinal conditions with significant mechanical instability or deformity requiring fusion with instrumentation. These conditions are significant mechanical instability or deformity of the thoracic, lumbar, and sacral spine secondary to severe spondylolisthesis (grades 3 and 4) of the L5-S1 vertebra, degenerative spondylolisthesis with objective evidence of neurologic impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, and failed previous fusion (pseudarthrosis). The safety and effectiveness of these devices for any other conditions are unknown.”
“Precaution: The implantation of pedicle screw spinal systems should be performed only by experienced spinal surgeons with specific training in the use of this pedicle screw spinal system because this is a technically demanding procedure presenting a risk of serious injury to the patient.”
(2) Class II (special controls), when a rigid pedicle screw system is intended to provide immobilization and stabilization of spinal segments in the thoracic, lumbar, and sacral spine as an adjunct to fusion in the treatment of degenerative disc disease and spondylolisthesis other than either severe spondylolisthesis (grades 3 and 4) at L5-S1 or degenerative spondylolisthesis with objective evidence of neurologic impairment. These pedicle screw systems must comply with the following special controls:
(i) The design characteristics of the device, including engineering schematics, must ensure that the geometry and material composition are consistent with the intended use.
(ii) Non-clinical performance testing must demonstrate the mechanical function and durability of the implant.
(iii) Device components must be demonstrated to be biocompatible.
(iv) Validation testing must demonstrate the cleanliness and sterility of, or the ability to clean and sterilize, the device components and device-specific instruments.
(v) Labeling must include the following:
(A) A clear description of the technological features of the device including identification of device materials and the principles of device operation;
(B) Intended use and indications for use, including levels of fixation;
(C) Identification of magnetic resonance (MR) compatibility status;
(D) Cleaning and sterilization instructions for devices and instruments that are provided non-sterile to the end user; and
(E) Detailed instructions of each surgical step, including device removal.
(3) Class II (special controls), when a semi-rigid system is intended to provide immobilization and stabilization of spinal segments in the thoracic, lumbar, and sacral spine as an adjunct to fusion for any indication. In addition to complying with the special controls in paragraphs (b)(2)(i) through (v) of this section, these pedicle screw systems must comply with the following special controls:
(i) Demonstration that clinical performance characteristics of the device support the intended use of the product, including assessment of fusion compared to a clinically acceptable fusion rate.
(ii) Semi-rigid systems marketed prior to the effective date of this reclassification must submit an amendment to their previously cleared premarket notification (510(k)) demonstrating compliance with the special controls in paragraphs (b)(2)(i) through (v) and paragraph (b)(3)(i) of this section.