510(k) Data Aggregation

    K Number
    K182620

    Validate with FDA (Live)

    Date Cleared
    2019-01-18

    (116 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Predicate For
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    • HE (External Hex) implants, stock abutments and stock copings (originally cleared per K101207)
    • Titamax CM (Cone Morse) implants, stock abutments and stock copings (originally cleared per K101945 ● and extended per K123022, K133696 and K150199)
    • Titamax CM (Cone Morse) EX implants, stock abutments and stock copings (originally cleared per K101945 and extended per K123022, K133696 and K150199)
    • Alvim CM (Cone Morse) implants, stock abutments and stock copings (originally cleared per K101945 and ● extended per K123022, K133696 and K150199)
    • CM (Cone Morse) Drive implants, stock abutments and stock copings (originally cleared per K123022 and extended per K133696, K150182 and K150199)
    • GM (Grand Morse) Titamax implants, stock abutments and stock copings (originally cleared per K163194)
    • GM (Grand Morse) Drive implants, stock abutments and stock copings (originally cleared per K163194) ●
    • . GM (Grand Morse) Helix implants, stock abutments and stock copings (originally cleared per K163194)

    The implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading. Multiple tooth applications may be rigidly splinted.

    • Titamax WS implants, abutments and copings (originally cleared per K123022)
      The implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth to restore chewing function. The Neodent Implant System may be used for single or multiple unit restorations. Multiple tooth applications may be rigidly splinted.

    The Titamax WS implants are indicated for a delayed loading protocol.

    • Facility implants, stock abutments and stock copings (originally cleared per K123022 and extended per K133696 and K150199)
      The implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth to restore chewing function. The Neodent Implant System may be used for single or multiple unit restorations. Multiple tooth applications may be rigidly splinted.

    The Facility implants of the Neodent Implant System are indicated for replacement of maxillary lateral incisors, mandibular incisors or retention of overdentures.

    • Zygomatic implants, stock abutments and stock copings (originally cleared per K141777)
      The Zygomatic implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading. Multiple tooth applications may be rigidly splinted.

    The Zygomatic implants of the Neodent Implant System are indicated for surgical installation in the zygoma region in cases of severe jaw resorption in order to restore patient esthetics and chewing function. Zygomatic implants are recommended for the posterior (pre-molar/ molar) region, one implant on each side, with at least two standard dental implants in the anterior region to support a fixed restoration.

    • CM (Cone Morse) Titanium Base Abutment component of two-piece patient-specific abutment (originally cleared per K150367 and extended per K153624)
    • o GM (Grand Morse) Exact Titanium Base Abutment component of two-piece patient-specific abutment (originally cleared per K163194)

    The implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading. Multiple tooth applications may be rigidly splinted.

    The Titanium Base Abutment is a titanium base placed onto Neodent dental implants to provide support for customized prosthetic restorations. The Titanium Base is used with a coping and crown, or crown alone, and is indicated for cement-retained single or multi-unit restorations, or screw-retained single restorations.

    All digitally designed copings and/or crowns for use with the Neodent Titanium Base Abutment are intended to be sent to Straumann for manufacture at a validated milling center.

    • CM (Cone Morse) Titanium Base for CEREC Abutment component of two-piece patient-specific abutment (originally cleared per K160964)
      The implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading. Multiple tooth applications may be rigidly splinted.

    The Titanium Base for CEREC Abutment is a titanium base placed onto Neodent dental implants to provide support for customized prosthetic restorations. They are used with a coping and crown, or crown alone, and is indicated for cement-retained single or multi-unit restorations, or screw-retained single restorations.

    All digitally designed copings and/or crowns for use with the Neodent Titanium Base for CEREC Abutment are to be designed using Sirona inLab software or Sirona CEREC Software and manufactured using a Sirona CEREC or inLab MC X or MC XL milling unit.

    • CM Preface Abutment component of patient-specific abutment (originally cleared per K150367)
      The implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading. Multiple tooth applications may be rigidly splinted.

    The Preface Abutment is a titanium abutment to be used in fabricating a full custom abutment placed onto Neodent dental implants to provide support for customized prosthetic restorations. The Preface Abutments is indicated for screw-retained single restorations or cement-retained single or multi-unit restorations.

    All digitally designed restorations for use with the Neodent Preface Abutment are intended to be sent to Straumann for manufacture at a validated milling center.

    • GM (Grand Morse) ProPEEK Abutments (originally cleared per K163194) ●
    • CM (Cone Morse) ProPEEK Abutments (originally cleared per K170080)

    The implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading. Multiple tooth applications may be rigidly splinted.

    The Pro PEEK Abutment is indicated to be used on Neodent implants to provide temporary support for prosthesis structure for up to 6 months.

    • Neodent Implant for Orthodontic Anchor (originally cleared per K102769) ●
      The Neodent Implant for Orthodontic Anchor is a surgical device in the form of a temporary screw used as an aid in orthodontic movement procedures.

    • . The Neodent Graft Screw (originally cleared per K103084)
      The Neodent Graft Screw is an implantable device used for fixation of bone blocks for the regeneration of bone in the oral cavity. The product is intended for temporary use only.

    Device Description

    Not Found

    AI/ML Overview

    The provided text is a 510(k) Premarket Notification from the FDA regarding the MRI compatibility of various Neodent Implant System devices. It primarily focuses on defining the indications for use for different components of the implant system and does not contain information about acceptance criteria, device performance studies, sample sizes, expert qualifications, or ground truth establishment for an AI/Medical Device.

    The document is a regulatory approval letter and descriptive indications for use, not a study report or technical performance assessment. Therefore, I cannot extract the requested information from this text.

    Ask a Question

    Ask a specific question about this device

    K Number
    K173343

    Validate with FDA (Live)

    Date Cleared
    2018-02-27

    (126 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K151909, K070841, K053478, K141777

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Southern Implants Zygomatic System Standard implants, Zygan (narrow apex) implants, and Oncology implants are intended to be implanted in the upper jaw arch to provide support for fixed or removable dental prostheses in patients with partially or fully edentulous maxillae. All implants are appropriate for immediate loading when good primary stability is achieved and with appropriate occlusal loading.

    Device Description

    This submission includes fully threaded and partially threaded root-form dental implants and mating abutments designed for placement into the zygomatic bone. All implants are provided with an external hexagon abutment interface angled 55° at the head of the implants are provided in three designs: Standard implant, fully threaded, diameter 4.3 mm (coronal) tapering to 3.8 mm (apical), in lengths of 30 mm and 57.5 mm; Zygan implant, partially threaded, diameter 4.3 mm (coronal) tapering to 3.4 mm (apical), in lengths from 30 mm to 57.5 mm; and Oncology implant, partially threaded diameter 4.3 mm (coronal) tapering to 3.8 mm (apical), in lengths from 30 mm to 47. 5 mm.

    This submission includes additional designs of Compact Conical Abutments (gingival heights 2, 3, 4, and 5.5 mm) for use with any of the implants. This submission also includes a Titanium Cylinder Abutment, for use with the Compact Conical Abutments, with a collar (gingival) height of 5 mm, and a prosthetic platform diameter of 3.4 mm. All subject device abutments are for support of screw-retained overdenture prosthetic restorations.

    All subject device implants are manufactured from unalloyed titanium conforming to ASTM F67. The threaded portions of the implants have the identical aluminum oxide grit-blasted surface as the implants cleared in K093562. The subject device Compact Conical Abutments are manufactured from titanium alloy conforming to ASTM F136. The subject device Titanium Cylinder Abutment is manufactured from unalloyed titanium conforming to ASTM F67. All of the subject device components are manufactured in the same facilities using the same manufacturing processes as used for the previously cleared predicate devices in K093562 and K070841.

    AI/ML Overview

    Based on the provided text, the document is a 510(k) Premarket Notification for the Southern Implants Zygomatic Implant System. This document does not describe a study involving an AI/Machine Learning device. Instead, it proves the substantial equivalence of a dental implant system to previously cleared predicate devices through non-clinical performance data and comparison of technological characteristics.

    Therefore, many of the requested criteria related to AI/ML device studies (e.g., sample size for test/training sets, data provenance, expert adjudication, MRMC studies, standalone performance, ground truth establishment) are not applicable to this document.

    However, I can extract information related to the acceptance criteria and the study (referred to as performance data) that proves the dental implant device meets those criteria.

    Here's a breakdown of the relevant information from the document:

    1. A table of acceptance criteria and the reported device performance

    The document doesn't present a formal table of acceptance criteria with corresponding performance numbers in the way an AI/ML study would. Instead, substantial equivalence is demonstrated through:

    • Identical intended use: The Zygomatic Implant System is intended to support fixed or removable dental prostheses in patients with partially or fully edentulous maxillae, identical to the predicate device.
    • Similar technological characteristics: Comparisons are made regarding design, dimensions (platform diameter, implant diameter, implant lengths, threaded lengths, connection angle), abutment design, interface, gingival height, abutment angle, prosthesis attachment, and materials.
    • Equivalent non-clinical performance: Biocompatibility, engineering analysis, dimensional analysis, sterilization validation, and dynamic compression-bending testing are the "performance data" used to demonstrate equivalence.
    Acceptance Criteria (Demonstrates Substantial Equivalence to Predicate)Reported Device Performance / Evidence
    Intended Use EquivalenceThe Indications for Use Statement for the subject device is similar to the primary predicate device (K093562). The subject device's statement includes additional Zygan and Oncology implants, but "the slight differences in wording... do not affect the intended use as dental implants placed into the zygoma for rehabilitation of the edentulous maxilla."
    Design Equivalence (Implants)Standard Implant: Identical design to K093562, with additional lengths. Zygan Implant: Substantially equivalent design to K093562 (differences: non-threaded region, tapering diameter to 3.4 mm at apex, range of lengths). These differences were accounted for by additional labeling instructions without impacting safety/effectiveness. Oncology Implant: Substantially equivalent design to K093562 (differences: non-threaded region, range of lengths). Reference to K151909 for substantial equivalence of Oncology implant design and range of implant lengths. Overall: Fully and partially threaded root-form implants for placement into the zygomatic bone. Platform Ø 4.05 mm (identical to predicate). Implant connection angle 55° (identical to predicate).
    Design Equivalence (Abutments)Compact Conical Abutments: Identical design to K070841, with only difference being additional sizes of gingival height (2.0 mm - 5.5 mm vs 1 mm for predicate). Reference to K070841. Titanium Cylinder Abutment: Identical design to K053478, with only difference being a change in gingival height (5 mm vs unspecified for predicate). Reference to K053478. Overall: One-piece, compact conical design. External hex; 55° angulation at head of implant. 0° (straight) abutment angle. Screw-retained, multi-unit prosthesis attachment.
    Materials EquivalenceImplants: Unalloyed titanium, ASTM F67 (identical to predicate). Abutments: Unalloyed titanium, ASTM F67; Titanium alloy, ASTM F136 (identical to predicate). Surface Treatment: Identical aluminum oxide grit-blasted surface as implants cleared in K093562. Biocompatibility: Supported by materials being identical in formulation, processing, component interactions, and storage conditions to predicate devices (K093562 and K070841). LAL Test: Conducted according to USP 39-NF 34 <85> Bacterial Endotoxin Test, using kinetic chromogenic method.
    Sterilization & Packaging EquivalenceProvided sterile for single-patient, single-use, identical to predicate devices. Subject device and predicate devices are packaged in similar materials and sterilized using similar methods. The subject device packaging is mostly the same as K093562, with a minor difference in additional packaging of the implant and mount within a rigid plastic cylinder inside the PET tray. This change was addressed with specific labeling precautions for handling and removal to maintain sterility.
    Mechanical Performance EquivalenceDynamic compression-bending testing was performed according to ISO 14801 ("Dentistry - Implants - Dynamic fatigue test for endosseous dental implants") on worst-case subject device constructs. Result: "The results from the testing demonstrated fatigue performance substantially equivalent to that of the reference device K141777." The reference device K141777 is also cited for substantial equivalence of the range of implant lengths and mechanical performance.
    Clinical Performance (Retrospective Data)A retrospective study was referenced to support the oncology implant design. Sample Size: 40 implants in 20 subjects. Performance: Demonstrated 100% implant success and no soft tissue complications up to 96 months. Source: Boyes-Varley JG, et al., Int J Prosthodont 2007; 20:521-531.

    2. Sample sizes used for the test set and the data provenance

    • Non-clinical testing: No specific "test set" sample sizes are given for the engineering, dimensional, biocompatibility tests (these often rely on established standards and in-vitro methods).
    • Clinical Data (referenced for Oncology implant):
      • Sample Size: 40 implants in 20 subjects.
      • Data Provenance: Retrospective (from a published study: Boyes-Varley JG, et al., 2007). The country of origin is not explicitly stated in this document but the journal International Journal of Prosthodontics is international, and one of the authors for the referenced paper (Boyes-Varley) appears to be associated with South Africa (which is also the manufacturer's location).

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    This is not applicable as this is a dental implant device approval based on substantial equivalence to existing devices, primarily through non-clinical testing and referencing a retrospective clinical study. "Ground truth" in the AI/ML sense (e.g., expert labels on images) is not relevant here. The "ground truth" for the retrospective clinical study would be observed patient outcomes.

    4. Adjudication method for the test set

    Not applicable. There's no expert adjudication process mentioned for this type of device.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is for a physical medical device (dental implant), not an AI/ML diagnostic or assistive tool.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is a physical device, not an algorithm.

    7. The type of ground truth used

    For the retrospective clinical data referenced for the Oncology implant:

    • Type of Ground Truth: Clinical outcomes data (implant success, soft tissue complications).

    For the non-clinical performance data (biocompatibility, mechanical testing, etc.):

    • Type of Ground Truth: Compliance with established international standards (e.g., ISO 14801, ISO 17665-1, ISO TS 17665-2, USP 39-NF 34 <85>) and comparison to the performance of legally marketed predicate devices.

    8. The sample size for the training set

    Not applicable. This is a physical device, not an AI/ML model that requires a training set.

    9. How the ground truth for the training set was established

    Not applicable. See point 8.