510(k) Data Aggregation

    K Number
    K182620

    Validate with FDA (Live)

    Date Cleared
    2019-01-18

    (116 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Predicate For
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    • HE (External Hex) implants, stock abutments and stock copings (originally cleared per K101207)
    • Titamax CM (Cone Morse) implants, stock abutments and stock copings (originally cleared per K101945 ● and extended per K123022, K133696 and K150199)
    • Titamax CM (Cone Morse) EX implants, stock abutments and stock copings (originally cleared per K101945 and extended per K123022, K133696 and K150199)
    • Alvim CM (Cone Morse) implants, stock abutments and stock copings (originally cleared per K101945 and ● extended per K123022, K133696 and K150199)
    • CM (Cone Morse) Drive implants, stock abutments and stock copings (originally cleared per K123022 and extended per K133696, K150182 and K150199)
    • GM (Grand Morse) Titamax implants, stock abutments and stock copings (originally cleared per K163194)
    • GM (Grand Morse) Drive implants, stock abutments and stock copings (originally cleared per K163194) ●
    • . GM (Grand Morse) Helix implants, stock abutments and stock copings (originally cleared per K163194)

    The implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading. Multiple tooth applications may be rigidly splinted.

    • Titamax WS implants, abutments and copings (originally cleared per K123022)
      The implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth to restore chewing function. The Neodent Implant System may be used for single or multiple unit restorations. Multiple tooth applications may be rigidly splinted.

    The Titamax WS implants are indicated for a delayed loading protocol.

    • Facility implants, stock abutments and stock copings (originally cleared per K123022 and extended per K133696 and K150199)
      The implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth to restore chewing function. The Neodent Implant System may be used for single or multiple unit restorations. Multiple tooth applications may be rigidly splinted.

    The Facility implants of the Neodent Implant System are indicated for replacement of maxillary lateral incisors, mandibular incisors or retention of overdentures.

    • Zygomatic implants, stock abutments and stock copings (originally cleared per K141777)
      The Zygomatic implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading. Multiple tooth applications may be rigidly splinted.

    The Zygomatic implants of the Neodent Implant System are indicated for surgical installation in the zygoma region in cases of severe jaw resorption in order to restore patient esthetics and chewing function. Zygomatic implants are recommended for the posterior (pre-molar/ molar) region, one implant on each side, with at least two standard dental implants in the anterior region to support a fixed restoration.

    • CM (Cone Morse) Titanium Base Abutment component of two-piece patient-specific abutment (originally cleared per K150367 and extended per K153624)
    • o GM (Grand Morse) Exact Titanium Base Abutment component of two-piece patient-specific abutment (originally cleared per K163194)

    The implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading. Multiple tooth applications may be rigidly splinted.

    The Titanium Base Abutment is a titanium base placed onto Neodent dental implants to provide support for customized prosthetic restorations. The Titanium Base is used with a coping and crown, or crown alone, and is indicated for cement-retained single or multi-unit restorations, or screw-retained single restorations.

    All digitally designed copings and/or crowns for use with the Neodent Titanium Base Abutment are intended to be sent to Straumann for manufacture at a validated milling center.

    • CM (Cone Morse) Titanium Base for CEREC Abutment component of two-piece patient-specific abutment (originally cleared per K160964)
      The implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading. Multiple tooth applications may be rigidly splinted.

    The Titanium Base for CEREC Abutment is a titanium base placed onto Neodent dental implants to provide support for customized prosthetic restorations. They are used with a coping and crown, or crown alone, and is indicated for cement-retained single or multi-unit restorations, or screw-retained single restorations.

    All digitally designed copings and/or crowns for use with the Neodent Titanium Base for CEREC Abutment are to be designed using Sirona inLab software or Sirona CEREC Software and manufactured using a Sirona CEREC or inLab MC X or MC XL milling unit.

    • CM Preface Abutment component of patient-specific abutment (originally cleared per K150367)
      The implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading. Multiple tooth applications may be rigidly splinted.

    The Preface Abutment is a titanium abutment to be used in fabricating a full custom abutment placed onto Neodent dental implants to provide support for customized prosthetic restorations. The Preface Abutments is indicated for screw-retained single restorations or cement-retained single or multi-unit restorations.

    All digitally designed restorations for use with the Neodent Preface Abutment are intended to be sent to Straumann for manufacture at a validated milling center.

    • GM (Grand Morse) ProPEEK Abutments (originally cleared per K163194) ●
    • CM (Cone Morse) ProPEEK Abutments (originally cleared per K170080)

    The implants, abutments and copings of the Neodent Implant System are intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading. Multiple tooth applications may be rigidly splinted.

    The Pro PEEK Abutment is indicated to be used on Neodent implants to provide temporary support for prosthesis structure for up to 6 months.

    • Neodent Implant for Orthodontic Anchor (originally cleared per K102769) ●
      The Neodent Implant for Orthodontic Anchor is a surgical device in the form of a temporary screw used as an aid in orthodontic movement procedures.

    • . The Neodent Graft Screw (originally cleared per K103084)
      The Neodent Graft Screw is an implantable device used for fixation of bone blocks for the regeneration of bone in the oral cavity. The product is intended for temporary use only.

    Device Description

    Not Found

    AI/ML Overview

    The provided text is a 510(k) Premarket Notification from the FDA regarding the MRI compatibility of various Neodent Implant System devices. It primarily focuses on defining the indications for use for different components of the implant system and does not contain information about acceptance criteria, device performance studies, sample sizes, expert qualifications, or ground truth establishment for an AI/Medical Device.

    The document is a regulatory approval letter and descriptive indications for use, not a study report or technical performance assessment. Therefore, I cannot extract the requested information from this text.

    Ask a Question

    Ask a specific question about this device

    K Number
    K173902

    Validate with FDA (Live)

    Date Cleared
    2018-04-20

    (119 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K101207, K121843, K133696

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Neodent Implant System is intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading.

    Device Description

    The purpose of this submission is to expand the Neodent Implant System - GM Line components cleared under K163194, which included dental implants with a Morse taper abutment interface (called Grand Morse, or GM), mating abutment screws, and other associated components. This submission includes the GM Exact Co-Cr Abutment for Crown and the GM Equator Attachment. The subject device components mate exclusively with the GM implants cleared in K163194.

    The GM Exact Co-Cr Abutment for Crown is provided in three sizes to fit the prosthetic diameter sizes of the GM implants cleared in K163194. The subject device abutments consist of a Co-Cr alloy component that interfaces directly to the implant and a cvlinder of polyoxymethylene (POM) for fabrication of a cast prosthesis by a burn-out technique. The subject device abutments are provided in three (3) sizes to match the various platforms of the mating GM implants: 3.5/3.75 mm platform diameter, 4.0/4.3 mm platform diameter, and 5.0/6.0 mm platform diameter. The subject device abutments are for single-unit prosthetic restorations only. The final prosthetic restoration may be cement-retained or screw-retained.

    The GM Equator Attachment abutments are straight, ball-type abutments for the attachment of full or partial overdentures. GM Equator Attachments are provided in five gingival heights (1.5, 2.5, 3.5, 4.5, and 5.5 mm), and may be used with all GM implant diameter sizes cleared in K163194.

    The subject device GM Exact Co-Cr abutments are made of Co-Cr alloy conforming to ASTM F1537, with mating abutment screws made of titanium alloy conforming to ASTM F136. The GM Equator Attachments made of titanium alloy conforming to ASTM F136 with a TiN coating identical to the TiN coating cleared in K133696.

    AI/ML Overview

    This document describes the Neodent Implant System - GM Line, specifically introducing new abutment components. Based on the provided text, the acceptance criteria and study information are focused on demonstrating substantial equivalence to predicate devices rather than proving performance against specific acceptance criteria for a novel device. The document mainly uses non-clinical performance data (biocompatibility, sterilization validation, shelf-life, bacterial endotoxin testing) to support this claim.

    Here's a breakdown of the requested information based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    The document does not explicitly state "acceptance criteria" in terms of specific performance metrics for the device (e.g., accuracy, sensitivity, specificity, or clinical outcomes). Instead, the performance data presented is aimed at demonstrating the device's characteristics are comparable to predicate devices. The "performance" is primarily shown through a comparison of technological characteristics and non-clinical testing results to existing standards and predicate devices to establish substantial equivalence.

    Acceptance CriterionReported Device Performance (as demonstrated by comparison/testing)
    BiocompatibilityDemonstrated through testing according to ISO 10993-5, ISO 10993-12, and ISO 10993-18 for the GM Exact Co-Cr Abutment for Crown. Biocompatibility of titanium alloy components referenced to K163194 and K133696.
    Sterilization ValidationPerformed according to ISO 17665-1, ISO TS 17665-2, ISO 11135, and ISO 10993-7.
    Sterile Barrier Shelf LifePerformed on real-time aged samples (referenced from K163194), including seal strength, helium leak detection, and sterility testing of package contents.
    Bacterial Endotoxin TestingPerformed using methods described in AAMI / ANSI ST72.
    Material CompositionGM Exact Co-Cr Abutment for Crown: Co-Cr alloy conforming to ASTM F1537; Mating abutment screws: Ti-6Al-4V alloy, ASTM F136. GM Equator Attachments: Ti-6Al-4V alloy, ASTM F136 with TiN coating. (Demonstrates equivalence or compliance to accepted material standards).
    Mechanical Design/InterfaceSubject device abutments have identical implant interface design to Neodent GM implants cleared in K163194. Morse taper connection with internal hex prosthetic indexing. Straight (0°) angles only.
    Intended UseFunctional and esthetic rehabilitation of the edentulous mandible or maxilla, consistent with predicate devices.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document focuses on non-clinical testing and refers to standards. It does not specify "sample sizes" in the context of clinical test sets or patient data.

    • Sample size for testing: Not explicitly stated for each non-clinical test (e.g., number of abutments tested for biocompatibility or number of packages for shelf-life). However, regulatory standards (like ISO 10993, ISO 17665-1) inherently require specific sample sizes for valid testing.
    • Data Provenance: The manufacturer is JJGC Indústria e Comércio de Materiais Dentários S.A. based in Curitiba, Paraná, Brazil. The non-clinical testing would presumably have been conducted by or commissioned by this company, possibly in Brazil or by certified labs internationally. The data is non-clinical, not from human subjects, hence "retrospective or prospective" does not directly apply in the clinical sense.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This information is not applicable. The provided document details the submission for new components of an existing dental implant system, demonstrating substantial equivalence through non-clinical testing (biocompatibility, sterilization, material specifications). It does not involve diagnostic imaging or other subjective assessments that would require expert consensus for ground truth.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This information is not applicable, as there is no clinical test set requiring adjudication in the context of diagnostic interpretation or outcomes.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This information is not applicable. The device is a dental implant system (hardware), not a diagnostic AI device. Clinical data was explicitly not submitted: "Clinical data were not submitted in this premarket notification." Therefore, no MRMC study or AI-related comparative effectiveness was performed or is relevant to this submission.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    This information is not applicable. The device is a dental implant system (hardware), not an algorithm or AI device.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    For the non-clinical performance data, the "ground truth" or reference for evaluating compliance consists of:

    • International Standards: ISO 10993 series (biocompatibility), ISO 17665-1, ISO TS 17665-2, ISO 11135, ISO 10993-7 (sterilization), AAMI / ANSI ST72 (bacterial endotoxin testing).
    • Material Standards: ASTM F1537 (Co-Cr alloy), ASTM F136 (Ti-6Al-4V alloy).
    • Predicate Device Characteristics: Comparison of physical dimensions, design principles, intended use, and materials to established predicate devices (K163194, K101207, K121843, K133696) to demonstrate substantial equivalence.

    There is no "ground truth" in the sense of clinical expert consensus, pathology, or outcomes data, as clinical data was not submitted.

    8. The sample size for the training set

    This information is not applicable. This is a submission for a physical medical device (dental implant components), not a machine learning or AI algorithm that requires a "training set."

    9. How the ground truth for the training set was established

    This information is not applicable, as there is no training set for an algorithm.