510(k) Data Aggregation

    K Number
    K252320

    Validate with FDA (Live)

    Device Name
    SIMDA Abutments
    Manufacturer
    Date Cleared
    2025-12-18

    (146 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    SIMDA Abutments are intended for use with dental implants as a support for single or multiple tooth prostheses in the maxilla or mandible of a partially or fully edentulous patient.

    It is compatible with the following systems:

    Pre-Milled Blank, Patient-specific abutment

    Compatible SystemImplant Body Diameter(mm)Implant Platform
    Astra OsseoSpeed® EV (K120414, K130999)3.0, 3.6, 4.2, 4.8, 5.43.0, 3.6, 4.2, 4.8, 5.4
    Astra Tech Implant System (K101732) Astra Tech OsseoSpeed Astra Tech Fixture MicroMacro (New indication) (K024111)3.0S, 3.5S, 4.0S, 4.5, 5.0, 5.0S3.0(x-small), 3.5/4.0(small), 4.5/5.0(large)
    BioHorizons Laser-Lok 3.0 Implant System (K093321) BioHorizons Tapered Internal Implant System (K143022, K071638)3.0, 3.4, 3.8, 4.6, 5.83.0, 3.4, 3.8, 4.6, 5.8
    Biomet 3i Certain® (K130949)3.25, 4.0, 5.0, 6.03.25, 4.0, 5.0, 6.0
    Straumann BLX Implant (K173961, K181703, K191256)3.5, 3.75, 4.0, 4.5, 5.0, 5.5, 6.5RB, WB

    Ti-Base abutment

    Compatible SystemImplant Body Diameter(mm)Implant Platform
    BioHorizons Laser-Lok 3.0 Implant System (K093321) BioHorizons Tapered Internal Implant System (K143022, K071638)3.0, 3.4, 3.8, 4.6, 5.83.0, 3.4, 3.8, 4.6, 5.8
    Biomet 3i Certain® (K130949)3.25, 4.0, 5.0, 6.03.25, 4.0, 5.0, 6.0
    Straumann BLX Implant (K173961, K181703, K191256)3.5, 3.75, 4.0, 4.5, 5.0, 5.5, 6.5RB, WB

    Multi-unit abutment

    Compatible SystemImplant Body Diameter(mm)Implant Platform
    Straumann BLX Implant (K173961, K181703, K191256)3.5, 3.75, 4.0, 4.5, 5.0, 5.5, 6.5RB, WB

    Multi-unit Abutment is only compatible with Straumann BLX Implant System.

    All digitally designed abutments for use with SIMDA Abutments are intended to be sent to a SIMDA validated milling center for manufacture.

    Device Description

    SIMDA Abutment is intended for use as an aid in prosthetic restoration. It consists of Pre-Milled Blank, Ti-Base, Multi-unit Abutment, Multi-unit Base. It has a pre-manufactured connection interface that fits directly to an endosseous dental implant.

    Pre-milled Blank Design
    This device is a patient-specific abutment composed of titanium alloy (Ti-6Al-4V ELI, ASTM F136) which is designed by a clinician or lab, and milled at a SIMDA validated milling center.

    Pre-Milled Blank Design Limitation for Patient-specific abutment:

    Design parameter (Patient-specific abutment)Subject System Design Limit
    Minimum and Maximum Gingival (Cuff) Height0.5~5mm
    Minimum and Maximum diameter at abutment/implant interface4.0~8.0
    Minimum and Maximum length of abutment6~12mm
    Minimum and Maximum length of abutment post (length above the abutment collar/gingival height)4~8mm
    Minimum wall thickness at abutment/implant interface0.32 (Astra EV), 0.32 (Astra TX), 0.39 (BioHorizons), 0.4 (Biomet 3i), 0.42 (Straumann BLX)
    Minimum and Maximum abutment angle015º (Astra EV and Astra TX), 025º (BioHorizons, Biomet 3i, and Straumann BLX)

    Pre-Milled Blank Design Limitation for Patient-specific abutment:
    Astra OsseoSpeed EV, Astra Tech OsseoSpeed TX is minimum and maximum abutment angle 0~15 º

    Ti-Base Abutment
    Ti Base consists of a two-piece abutment, where the titanium base is a pre-manufactured titanium component that will be used to support a CAD/CAM-designed zirconia superstructure (the second part of the two-piece abutment) that composes the final abutment.

    Ti Base are provided non-sterile therefore must be sterilized after the cementation of the patient-specified superstructure.

    Raw material blanks

    • InCoris Zi (ZrO2) by Sirona Dental Systems GmbH, L size blanks, cleared under K123664.

    Cement

    • RelyX Unicem 2Automix by 3M ESPE, cleared under K100756.

    Design Limitation for Zirconia superstructure:

    Design ParameterLimit (Min.~Max.)
    Minimum and Maximum abutment angle0~15
    Minimum and Maximum Gingival (Cuff) Height0.5~5.0
    Minimum and Maximum length of abutment post (length above the abutment collar/gingival height)4.0~6.0
    Minimum and Maximum diameter at abutment/implant interface5.0~8.0
    Minimum wall thickness at abutment/implant interface0.33

    Multi-unit Abutment and Base
    Multi-unit Abutment which are placed into the dental implant to provide support for the prosthetic restoration. The abutments are made of Titanium grade Ti-6A1-4V ELI (meets ASTM Standard F136). The Multi-unit Abutment has a post height less than 4mm and are always combined with Multi-unit Base, increasing the post height to a minimum of 4.5mm.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K241485

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-10-09

    (138 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    TruAbutment DS is a patient-specific CAD/CAM abutment, which is directly connected to endosseous dental implants and is intended to be used as an aid in prosthetic rehabilitation. It is compatible with the following systems: Astra OsseoSpeed EV (K130999, K120414), Biomet 3i Full OSSEOTITE Tapered Certain (K130949), DIO UF (II) Internal Submerged (K161987, K170608, K173975), Neoss ProActive® (K083561), Osstem TS (K161604), Camlog Screw-Line (K083496), Conelog Screw-Line (K113779), Implant Direct Legacy2 (K192221), BioHorizons Internal Implant System (K093321, K143022, K071638), MegaGen AnyRidge Internal Implant (K140091). All digitally designed abutments and/or copings for use with the TruAbutments are intended to be sent to a TruAbutment-validated milling center for manufacture.

    TruBase is a titanium component that is directly connected to endosseous dental implants to provide support for patient-specific prosthetic restorations, such as copings or crowns. It is indicated for a screw-retained single tooth or cement-retained single tooth and bridge restorations. It is compatible with the following systems: Astra OsseoSpeed EV (K130999), Biomet 3i Full OSSEOTITE Tapered Certain (K130949), DIO UF(II) Internal Submerged (K161987, K170608, K173975), Neoss ProActive® (K083561), Camlog Screw-Line (K083496), Conelog Screw-Line (K113779), Implant Direct Legacy2 (K192221). All digitally designed abutments and/or copings for use with the TruAbutment are intended to be sent to a TruAbutment-validated milling center for manufacture.

    Device Description

    TruAbutment DS, TruBase and abutment screw are made of Titanium grade Ti-6A1-4V ELI (meets ASTM Standard F136). TruAbutment DS, TruBase are supplied with two identical screws which are used: (1) For fixing the abutment into the endosseous implant. (2) For dental laboratory use during construction of related restoration. TruAbutment DS, TruBase are provided non-sterile. Therefore, it must be sterilized before use. TruAbutment DS, TruBase are devices that can only be sold, distributed, or used upon the order of an authorized healthcare provider, generally referred to as prescription (Rx) devices.

    TruAbutment DS system includes patient-specific abutments that are placed into the dental implant to provide support for the prosthetic restoration. The subject abutments are indicated for serew-retained restorations. The design and manufacturing of the patient-specific abutments take into consideration the shape of the final prosthesis based on the patient's intra-oral indications using CAD/CAM system during the manufacturing. All manufacturing processes of TruAbutment DS are conducted at the TruAbutment milling center.

    TruBase is a two-piece abutment. The base component is premanufactured and is used to support a cemented CAD/CAM zirconia superstructure. The base and the zirconia superstructure together form the final abutment. CAD/CAM customized superstructure that composes the final abutment is intended to be sent to a TruAbutment-validated milling center to be designed and milled, according to the prosthetic planning and patient clinical situation. The superstructure is cemented to the TruBase in the lab. Use "RelyX Unicem 2Automix" as an adhesive extra orally to connect.

    AI/ML Overview

    The provided text is a 510(k) summary for the TruAbutment DS and TruBase devices. It primarily focuses on demonstrating substantial equivalence to a predicate device (TruAbutment DS, K203649) and does not detail an acceptance criteria table with reported device performance in the manner of a clinical study. The text describes non-clinical testing performed, but not a study designed to prove the device meets acceptance criteria related to a specific clinical outcome or diagnostic accuracy.

    Therefore, many of the requested items (acceptance criteria table, sample size for test/training sets, data provenance, expert ground truth, adjudication, MRMC studies, standalone performance, type of ground truth) are not applicable based on the content of this 510(k) summary, which is a premarket notification for a medical device primarily based on demonstrating substantial equivalence through engineering and mechanical testing, not clinical performance or AI algorithm validation studies.

    However, I can extract the information provided regarding non-clinical testing for the devices.


    Acceptance Criteria and Study for TruAbutment DS & TruBase

    Based on the provided 510(k) summary, the "acceptance criteria" and "study" described are focused on non-clinical mechanical performance testing and demonstration of substantial equivalence to a predicate device, rather than a clinical study proving performance against specific clinical or diagnostic accuracy metrics with human or AI components.

    Here's the relevant information extracted and presented based on the document:

    1. A table of acceptance criteria and the reported device performance

    The document does not provide a table with specific quantitative acceptance criteria alongside actual reported numerical performance results for the new devices in the context of a comparative study proving their performance against such criteria. Instead, it states that "The results of the above tests have met the criteria of the standard and demonstrated substantial equivalence with the reference devices." This implies a qualitative "met standard" outcome rather than specific numerical performance data.

    The tables provided describe the design limits of the devices and compare them to the predicate device, not performance data from a test:

    TruAbutment DS Design Parameters (Acceptance Criteria are implied by meeting these limits)

    Design ParameterSubject Device (TruAbutment DS) Design LimitPrimary Predicate Device (K203649) Design LimitReported Device Performance (Implied)
    Minimum and Maximum abutment angle (°)0 ~ 250 ~ 25Met specified range
    Minimum and Maximum cuff height (mm)0.5 ~ 6.00.5 ~ 6.0Met specified range
    Minimum and Maximum diameter at abutment/implant interface (Ø, mm)3.3 ~ 8.03.3 ~ 8.0Met specified range
    Minimum and Maximum length of the abutment (mm)6 ~ 116 ~ 11Met specified range
    Minimum wall thickness at abutment/implant interface (mm)0.40.4 ~ 0.9Met specified range
    Minimum and Maximum length of abutment post (length above the abutment collar / gingival height) (mm)4.0 ~ 7.04.0 ~ 7.0Met specified range

    TruBase Design Parameters (Acceptance Criteria are implied by meeting these limits)

    Design ParameterSubject Device (TruBase) Design LimitPrimary Predicate Device (K203649) Design LimitReported Device Performance (Implied)
    Minimum and Maximum angulation (°)0 ~ 150 ~ 15Met specified range
    Minimum and Maximum gingival (cuff) height (mm)0.5 ~ 5.00.5 ~ 5.0Met specified range
    Minimum and Maximum diameter at abutment/implant interface (Ø, mm)5.0 ~ 8.05.0 ~ 8.0Met specified range
    Minimum thickness (mm)0.40.4Met specified value
    Minimum and Maximum length of abutment post (length above the abutment collar / gingival height) (mm)4.0 ~ 6.04.0 ~ 6.0Met specified range

    For mechanical performance, the document states:
    "Mechanical performance testing was performed according to ISO 14801. For compatible OEM implant line, worst-case constructs were subjected to static compression and compression fatigue testing. The fatigue limit data for all other implant lines demonstrated the construct strengths to be sufficient for their intended use."

    This confirms that the acceptance criteria for mechanical performance were "sufficient for their intended use" as defined by ISO 14801 and worst-case testing, but quantitative results are not provided.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample Size for Test Set: The document mentions "worst-case constructs" were tested for mechanical performance, and "the entire system including all variations (all compatible implant bodies, dental abutments, and fixation screws)" was evaluated for MRI environment conditions. However, specific numerical sample sizes for these tests are not provided.
    • Data Provenance: The data comes from non-clinical laboratory testing following international standards (ISO 14801, ISO 17665-1/2, ISO 10993 series). The country of origin and retrospective/prospective nature are not applicable as it's not a clinical data study.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • This is not applicable. The "ground truth" for this type of device (dental abutments) is established through adherence to engineering design specifications, material standards (ASTM F136), and performance under mechanical stress tests (ISO 14801), as well as compliance with sterilization and biocompatibility standards. It does not involve expert interpretation of images or clinical outcomes in the same way an AI diagnostic device would.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • This is not applicable as there is no human interpretation or subjective assessment of data requiring adjudication. Testing is based on objective measurements against engineering standards.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • This is not applicable. The device is an endosseous dental implant abutment, not an AI diagnostic tool.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • This is not applicable. The device is a physical dental component, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • The "ground truth" for validating these devices is adherence to engineering specifications, material properties, and performance standards (e.g., passing specific load-bearing and fatigue tests per ISO 14801, meeting biocompatibility requirements, maintaining dimensional accuracy). "Dimensional analysis and reverse engineering" were used to confirm compatibility.

    8. The sample size for the training set

    • This is not applicable. There is no "training set" as this is a physical medical device, not an AI/machine learning algorithm.

    9. How the ground truth for the training set was established

    • This is not applicable for the reason above.

    Summary of the Study Proving Device Meets Criteria (Based on Provided Text):

    The "study" conducted was primarily non-clinical laboratory testing to demonstrate the mechanical performance, sterilization efficacy, and biocompatibility of the TruAbutment DS and TruBase devices. The objective was to show substantial equivalence to an existing legally marketed device (TruAbutment DS, K203649) by proving that the new devices meet established design limits and performance standards relevant to dental implant abutments.

    • Mechanical Testing: Performed on "worst-case constructs" according to ISO 14801 for static compression and compression fatigue. The outcome was that "construct strengths [were] sufficient for their intended use."
    • Sterilization Testing: Performed per ISO 17665-1:2006, 17665-2:2009 and ANSI/AAMI ST79:2010.
    • Biocompatibility Testing: Performed per ISO 10993-1:2009, ISO 10993-5:2009, and ISO 10993-10:2010.
    • MRI Environment Evaluation: A non-clinical worst-case MRI review was done using scientific rationale and published literature to assess magnetically induced displacement force and torque.
    • Dimensional Analysis and Reverse Engineering: Conducted on the implant-to-abutment connection platform to assess critical design aspects and tolerances, confirming compatibility.

    The overall conclusion was that the devices "met the criteria of the standard and demonstrated substantial equivalence with the reference devices," thus indicating they met their implied acceptance criteria for safety and performance as medical devices. Clinical testing was explicitly stated as "not necessary."

    Ask a Question

    Ask a specific question about this device

    K Number
    K230438

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2023-12-29

    (311 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K220517, K200817, K123664, K100756

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    URIS Smart Path Implant System & Prosthetic is indicated for use in partially or fully edentulous mandibles and maxillae, in support of single or multiple-unit restorations including; cemented retained, or overdenture restorations, and final or temporary abutment support for fixed bridgework. It is intended for delayed loading.

    All digitally designed abutments and/or coping for use with URIS Smart Path Prosthetic abutments are intended to be sent to a TruAbutment-validated milling center for manufacture.

    Device Description

    URIS Smart Path Implant System fixtures are dental implants made of Unalloyed Titanium, grade 4 (ASTM F67) intended for use in partially or fully edentulous mandibles and maxillae, in support of single or multipleunit restorations. The surface treated is SLA (Sandblasted, Large grit and Acid etched) and is provided sterile. It consists of two implant lines, the Smart Path OMNI Thread and the Smart Path extra aggressive Thread, with corresponding cover screws, healing abutments. The Smart Path implant has a tapered wall with a single thread design. The Smart Path extra aggressive Thread is straight walled with smaller threading at the coronal end, and bigger threading at the apical end.

    URIS SP Prosthetic System is made of titanium alloy (Ti-6Al-4V ELI) intended for use as an aid in prosthetic restoration. It consists of SP Healing Abutment, SP Temporary Abutment, SP Multi-Unit Straight Abutment, SP Multi-Unit Angled Abutment, SP T-L Straight Abutment, URIS SP Base, URIS SP DS, SP Abutment Screw.

    Cover screw and healing abutment are anodized in yellow or green or purple.

    Fixtures and cover screw are provided sterile and other prosthetics are provided non-sterile. All non-sterile products must be sterilized by end users before use.

    URIS SP Base consists of a two-piece abutment, where the titanium base is a pre-manufactured abutment that will be used to support a CAD/CAM designed superstructure (the second part of the two-piece abutment) that composes the final abutment. URIS Base is made of titanium alloy conforming to ASTM F136 Standard Specification for Wrought Titanium-6Aluminum-4Vanadium ELI (Extra Low Interstitial) Alloy for Surgical Implant Applications.

    AI/ML Overview

    The provided text is a 510(k) Summary for the URIS Smart Path Implant System & Prosthetic. It describes the device, its intended use, and argues for its substantial equivalence to predicate devices based on technological characteristics and non-clinical testing.

    However, the document does not contain any information about acceptance criteria or a study that specifically proves the device meets acceptance criteria in the context of clinical performance or diagnostic accuracy, which are typically associated with the questions asked.

    The document focuses on non-clinical tests to demonstrate substantial equivalence, as is common for dental implants and prosthetics. These tests are primarily related to material properties, sterilization, packaging, and mechanical fatigue.

    Therefore, most of the requested information cannot be extracted from this document, as it pertains to clinical performance/accuracy studies which were explicitly stated as not included: "No clinical data were included in this submission."

    Here's a breakdown of what can be extracted and what information is missing:

    1. A table of acceptance criteria and the reported device performance

    Test PerformedAcceptance Criteria (Explicitly Stated in Document)Reported Device Performance (as stated in Document)
    Bacterial Endotoxin Testing (LAL)In accordance with USP <85> and USP <161>"met the standards"
    Sterilization TestingAccording to ISO 11137-1,-2,-3 and ISO 11737-1,-2"met the standards"
    Shelf Life TestingAccording to ISO 11607-1,-2 / ASTM F1980-07, ASTM F88, ASTM F1140, ASTM F1929, ASTM F2096 and sterility testing"met the standards"
    Biocompatibility TestingBased on ISO 10993-1Leveraged from predicate and reference devices (K172100 and K200817) and determined to be similar based on similar materials and manufacturing processes.
    SEM and EDS analysis for SLA surface treatment(Implicit: demonstrate identical surface treatment characteristics as predicate/reference)Leveraged from prior clearance for identical SLA surface treatment and manufacturing.
    Human Factors testing (usability evaluation for aseptic presentation)In line with ISO 11607-1:2019 and FDA guidance "Applying Human Factors and Usability Engineering to Medical Devices."(Implied: met standards, no specific results reported)
    Evaluation of broken tip at various degrees of rotation after removal from packaging(Implicit: prevention of device damage during removal)(Implied: met standards, no specific results reported)
    Quality System (QS) plan for packaging designEnsure devices conform with product specifications(Implied: met standards, no specific results reported)
    Fatigue testing (for endosseous dental implants)According to "Guidance for industry and FDA staff Class II Special Controls Guidance Document Root-form Endosseous Dental Implants and Endosseous Dental Abutment" and ISO 14801:2016 under worst-case scenario."met the standards"
    MR Environment Condition (Magnetically Induced Displacement Force and Torque on metal alloys)Based on FDA guidance "Testing and Labeling Medical Devices for Safety in the Magnetic Resonance (MR) Environment"(Implied: evaluated and deemed safe, no specific results reported)

    Missing Information (Not present in the provided document):

    1. Sample sizes used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective): Not applicable, as no clinical studies with test sets were performed. Non-clinical tests typically report sample sizes per test standard, but these are not detailed here beyond stating "worst-case scenario" for fatigue testing.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable, as no clinical studies requiring ground truth establishment were performed.
    3. Adjudication method (e.g., 2+1, 3+1, none) for the test set: Not applicable, as no clinical studies requiring adjudication were performed.
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. This device is a dental implant system, not an AI-powered diagnostic tool, and no clinical studies were performed.
    5. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done: Not applicable. This is not an algorithm-only device.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.): Not applicable, as no clinical studies requiring ground truth were performed.
    7. The sample size for the training set: Not applicable, as no AI/machine learning component requiring a training set is described.
    8. How the ground truth for the training set was established: Not applicable, as no AI/machine learning component requiring a training set is described.
    Ask a Question

    Ask a specific question about this device

    K Number
    K232271

    Validate with FDA (Live)

    Device Name
    SIMDA abutment
    Manufacturer
    Date Cleared
    2023-10-26

    (87 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    SIMDA Abutments are intended for use with dental implants as a support for single or multiple tooth prostheses in the maxilla or mandible of a partially or fully edentulous patient.

    Device Description

    SIMDA Abutment is made of titanium alloy (Ti-6Al-4V ELI, ASTM F136) intended for use as an aid in prosthetic restoration. It consists of Pre-Milled Blank and Ti-Base abutment. It has a premanufactured connection interface that fits directly to an endosseous dental implant.

    AI/ML Overview

    This FDA 510(k) summary describes a dental device, the SIMDA Abutment. However, it does not include information that directly addresses the specific questions you've asked about acceptance criteria and a study proving a device meets them, particularly for an AI/ML powered device.

    Here's why and what information is provided:

    The document is a premarket notification for a Class II medical device, specifically dental implant abutments. These are physical components used in dental restorations, not an AI/ML powered diagnostic or therapeutic device. Therefore, the concepts of "acceptance criteria for an AI model," "test set," "ground truth," "MRMC studies," "effect size of human readers with AI assistance," or "standalone algorithm performance" are not applicable to this submission.

    The "studies" mentioned are non-clinical (mechanical, biological) tests demonstrating the physical safety and performance of the abutments and their compatibility with existing dental implant systems.

    Here's a breakdown of the relevant information provided, framed as closely as possible to your request, but acknowledging the device type:


    Device: SIMDA Abutments (K232271)
    Device Type: Endosseous Dental Implant Abutment (physical medical device, not AI/ML powered)

    1. A table of acceptance criteria and the reported device performance

    The document sets design limits and then demonstrates conformity through non-clinical testing. The "acceptance criteria" here are rather design specifications and performance standards for dental abutments.

    Acceptance Criteria (Design Parameters/Limitations)Reported Device Performance (Demonstrated through testing)
    Pre-Milled Blank (for Patient-specific abutment):
    - Minimum and Maximum Gingival (Cuff) Height: 0.5~5mm"The minor difference between the two products in the design parameters [...] was evaluated as part of the performance testing and was determined to not impact the performance of the device." - Implies device meets these parameters and performs acceptably.
    - Minimum and Maximum diameter at abutment/implant interface: Ø4.0~Ø8.0
    - Minimum and Maximum length of abutment: 4.5~13mm
    - Minimum and Maximum length of abutment post (length above the abutment collar/gingival height): 4~8mm
    - Minimum wall thickness at abutment/implant interface: 0.4mm (Predicate: 0.4mm, Proposed: 0.39~0.55mm)"This change in technological characteristics [minimum thickness] was evaluated as part of the performance testing and was determined to not impact the performance of the device." - Indicates the slightly wider range for the proposed device (0.39-0.55mm) still met performance requirements.
    - Minimum and Maximum abutment angle: 0~25°
    Ti-Base (for Zirconia top-half):
    - Post Angle (°): 0~15Identical to predicate. Non-clinical testing results "demonstrated the substantial equivalence with the primary predicate."
    - Cuff Height (mm): 0.5~5.0
    - Post Length (mm): 4.0~6.0
    - Diameter (Ø, mm): 5.0~8.0
    - Thickness (mm): 0.4
    General Performance:
    - Fatigue Resistance: Must meet ISO 14801 and FDA special controls guidance.Fatigue testing followed ISO 14801 and the FDA special controls guidance document. Results "demonstrated the substantial equivalence with the primary predicate."
    - Sterilization Efficacy: Must meet ISO 17665-1:2006, 17665-2:2009, ANSI/AAMI ST79:2010.End User Steam Sterilization Test according to ISO 17665-1:2006, 17665-2:2009 and ANSI/AAMI ST79:2010. Results "demonstrated the substantial equivalence with the primary predicate."
    - Biocompatibility: Must meet ISO 10993-1:2009, ISO 10993-5:2009, and ISO 10993-10:2010.Biocompatibility tests according to ISO 10993-1:2009, ISO 10993-5:2009, and ISO 10993-10:2010. Results "demonstrated the substantial equivalence with the primary predicate."
    - MRI Safety: Must address magnetically induced displacement force and torque (per FDA guidance "Testing and Labeling Medical Devices for Safety in the Magnetic Resonance (MR) Environment")."Non-clinical worst-case MRI review was performed... using scientific rationale and published literature... Rationale addressed parameters per the FDA guidance... including magnetically induced displacement force and torque." - Implies the device is deemed safe in the MR environment based on this review.
    - Compatibility with OEM Implant Systems: Precision implant/abutment interface.Dimensional analysis and reverse engineering of critical features... Cross sectional images were provided to demonstrate substantially equivalent compatibility. The testing aided implant to abutment compatibility and has established substantial equivalency of the proposed device with the predicate device.

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • This information is not provided. For physical tests (fatigue, biocompatibility, sterilization), sample sizes would typically be determined by the relevant ISO standards.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • Not applicable. "Ground truth" in the context of AI/ML is not relevant here. The "truth" is established by physical measurement, adherence to material standards, and documented mechanical performance.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not applicable. Adjudication methods are typically for subjective assessments, whereas these are objective physical tests.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • Not applicable. This is a physical dental device, not an AI-assisted diagnostic tool.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Not applicable. This is a physical dental device.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • For physical tests, the "ground truth" is defined by the ISO standards and FDA guidance documents to which the device is tested. This includes established methods for fatigue testing, biocompatibility evaluation, and sterilization efficacy. For compatibility, it's about precise dimensional matching and mechanical fit to existing OEM implant systems.

    8. The sample size for the training set

    • Not applicable. This is a physical dental device, not an AI/ML powered device that requires a "training set."

    9. How the ground truth for the training set was established

    • Not applicable. See point 8.

    In summary, this document is for a traditional medical device (dental abutments), and thus the questions formulated for an AI/ML device do not directly apply. The acceptance criteria are based on established engineering and materials standards, and performance is demonstrated through non-clinical laboratory testing rather than clinical or observational studies on diagnostic performance.

    Ask a Question

    Ask a specific question about this device

    K Number
    K200817

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2020-10-07

    (191 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Predicate For
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    URIS OMNI Narrow System is indicated for use in the treatment of missing maxillary lateral incisors or the mandbular central and lateral incisors, in support of single or multiple-unit restorations including: cemented retained, or overdenture restorations, and final or temporary abutment support for fixed bridgework. It is intended for delayed loading.

    The URIS OMNI Prosthetic abutments are intended for use with URIS OMNI dental implants to provide support for prosthetic restorations such as crowns, bridges, or over-dentures.

    All digitally designed abutments and/or coping for use with URIS OMNI Prosthetic abutments are intended to be sent to a TruAbutment-validated milling center for manufacture.

    Device Description

    URIS OMNI Narrow System fixtures are dental implants made of Unalloyed Titanium, grade 4 (ASTM F67) intended for use in the treatment of missing maxillary lateral incisors or the mandibular central and lateral incisors. The surface is SLA (Sandblasted, Large grit and Acid etched) treated and is provided sterile. It consists of two implant lines, the OMNI Straight and the OMNI Tapered, with corresponding cover screws, healing abutments and prosthetic abutments. The OMNI Tapered implant has a tapered wall with a single thread design. The OMNI Straight implant has straight wall with smaller threading at the coronal end, and bigger threading at the apical end. Both implant lines have Narrow (Ø 3.15 mm) platform sizes. Both implant lines share the following diameters and lengths.

    Ø 3.15 x 10, 11.5, 13, 14.5mm (L)

    URIS Prosthetic System is made of titanium alloy (Ti-6Al-4V ELI) intended for use as an aid in prosthetic restoration. It consists of Ball Abutment, Retainer, T LOC Straight Abutment, T Loc Titanium Cap, Multi-Unit Straight Abutment, Multi-Unit Angled Abutment, Multi-Unit Healing Cap, Multi-Unit Ti Cylinder, Multi-unit temporary cylinder, Multi-Unit Cylinder screw, URIS DS, URIS Base. No additional angulation is to be included in the when using a coping or cylinder (i.e., Multi-unit Ti Cylinder, Multi-unit Temporary Cylinder, Multi-unit Base) with any of the Multi-unit Abutments.

    URIS Base consists of a two-piece abutment, where the titanium base is a pre-manufactured abutment that will be used to support a CAD/CAM designed superstructure (the second part of the two-piece abutment) that composes the final abutment. URIS Base is made of titanium alloy conforming to ASTM F136 Standard Specification for Wrought Titanium-4Vanadium ELI (Extra Low Interstitial) Alloy for Surgical Implant Applications.

    URIS DS abutment as a patient matched titanium abutment compatible with both URIS OMNI System (K172100) and URIS OMNI Narrow System (subject).

    AI/ML Overview

    The provided document is a 510(k) Summary for a dental implant system. It discusses the substantial equivalence of the "URIS OMNI Narrow System & Prosthetic" to predicate devices based on non-clinical testing. The document does not contain information about acceptance criteria or a study proving the device meets acceptance criteria in the context of human reader performance or a standalone algorithm performance for AI/ML-driven devices.

    The document states: "No clinical data were included in this submission." and focuses on demonstrating substantial equivalence through comparisons of technological characteristics and non-clinical test data.

    Therefore, I cannot provide the requested information for an AI/ML device related to acceptance criteria, detailed study design, sample sizes, expert ground truth, adjudication methods, or MRMC comparative effectiveness studies, as these types of studies are not discussed in this 510(k) summary for this device.

    The "acceptance criteria" presented in this document are primarily related to the successful completion and results of non-clinical tests to demonstrate equivalence to predicate devices. These are not performance metrics for an AI/ML algorithm.

    Here's an analysis of what is provided regarding acceptance criteria in the context of this traditional medical device:

    1. A table of acceptance criteria and the reported device performance:

    The document implicitly defines acceptance criteria by listing the standards to which tests were performed and stating that "the results have met the criteria of the standards." The "reported device performance" is that it successfully met these standards, thereby demonstrating substantial equivalence.

    Acceptance Criteria (Standards Met)Reported Device Performance
    USP <85> and USP <161> for Bacterial EndotoxinMet the criteria of the standards
    ISO 10993-1 for BiocompatibilityMet the criteria of the standards
    ISO 11137-1,-2,-3 and ISO 11737-1,-2 for SterilizationMet the criteria of the standards
    ISO 17665-1,-2 for End user sterilizationMet the criteria of the standards
    ISO 11607-1,-2 / ASTM F1980-07, ASTM F88, ASTM F1140, ASTM F1929, ASTM F2096 and sterility testing for Shelf LifeMet the criteria of the standards
    ISO 14801:2016 and FDA Guidance for Fatigue TestingMet the criteria of the standards ("worst-case scenario")
    SEM and EDS analysisPerformed (implied acceptable by equivalence conclusion)

    2. Sample size used for the test set and the data provenance:
    Not applicable for this type of non-clinical, non-AI device study. The document refers to testing on the device itself (e.g., fatigue testing, sterilization testing, biocompatibility).

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience):
    Not applicable. Ground truth as typically understood for AI/ML performance is not relevant here. The "ground truth" for these tests would be the accepted parameters and methods defined by the referenced ISO/ASTM standards and FDA guidance.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:
    Not applicable. This is not a human reader or AI performance study.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:
    No. This is not an AI/ML device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:
    No. This is not an AI/ML device.

    7. The type of ground truth used (expert concensus, pathology, outcomes data, etc):
    Not applicable in the context of AI/ML device performance. For the described non-clinical tests, the "ground truth" is defined by the specific parameters and requirements of the referenced ISO/ASTM standards. For example, for biocompatibility, the ground truth is whether the materials meet the criteria specified in ISO 10993-1.

    8. The sample size for the training set:
    Not applicable. This is not an AI/ML device.

    9. How the ground truth for the training set was established:
    Not applicable. This is not an AI/ML device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K120378

    Validate with FDA (Live)

    Date Cleared
    2012-03-30

    (52 days)

    Product Code
    Regulation Number
    872.3275
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K081583,K100756

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    • [1] Cementation of crowns, bridges, inlays and onlays made of porcelain, ceramic, composite resin or metal
    • [2] Cementation of porcelain, ceramic, composite resin or metal restorations on implant abutments
    • [3] Cementation of metal cores, resin cores, metal posts or glass fiber posts
    Device Description

    PANAVIA SA CEMENT Handmix is a dual-curc (light- and/or self-cure), radiopaque self-adhesive resin cement for porcelain, ceramic, composite resin and metal restorations. It is intended for the following indications:
    (1) Cementation of crowns, bridges, inlays and onlays made of porcelain, ceramic, composite resin or metal
    (2) Cementation of porcelain, ceramic, composite resin or metal restorations on implant abutments
    (3) Cementation of metal cores, resin cores, metal posts or glass fiber posts
    It is classified into dental cement (21 CFR section 872,3275. Product code: EMA ) according to 21 CFR§872 since it is composed of various materials other than zinc oxide-eugenol.
    Physical and mechanical properties of the subject device were evaluated according to ISO 4049: 2009 (Dentistry - Polymer-based restorative and materials). According to ISO 4049: 2009, the subject device is classified into the following:
    Class 3: materials that are cured by the application of external energy and also have a self-curing mechanism present
    (This product contains the adhesive monomer. ISO 4049:2009 does not cover the polymer-based luting materials that have an adhesive component within the structure of the material. However, we tested referring to this standard.)

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study information for the PANAVIA SA CEMENT Handmix device, based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria (Set by ISO 4049:2009 for Class 3 Polymer-based Restorative Materials)Reported Device Performance (PANAVIA SA CEMENT Handmix)
    Compliance with all requirements of ISO 4049: 2009 for polymer-based restorative and materials.Complies with all requirements of ISO 4049: 2009.
    Bond strength equivalent to predicate devices.Bond strength is equivalent to that of the predicate devices.

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not explicitly state a specific sample size for a "test set" in the context of clinical performance or a separate evaluation. The performance claims are based on compliance with an ISO standard and comparison to predicate devices, which implies lab-based testing. Therefore, we cannot determine a sample size for a test set, its provenance, or whether it was retrospective or prospective from this document.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Their Qualifications

    Not applicable. The "ground truth" for the device's performance is established by its compliance with the physical and mechanical property requirements of ISO 4049:2009 and comparison of bond strength to predicate devices. This type of evaluation does not typically involve expert consensus on a test set of clinical cases.

    4. Adjudication Method for the Test Set

    Not applicable, as there is no mention of a clinical test set or adjudication process in the provided text.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done, and its effect size.

    No, a Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not mentioned or performed for this device. The evaluation focuses on the physical and mechanical properties of the dental cement itself, not on human reader performance with or without AI assistance.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done.

    Not applicable. This device is a dental cement, not an AI algorithm. Therefore, a standalone performance evaluation of an algorithm is not relevant.

    7. The type of ground truth used

    The "ground truth" for the device's performance is based on:

    • A recognized international standard: ISO 4049:2009 (Dentistry - Polymer-based restorative and materials). This standard defines specific physical and mechanical properties that the material must meet.
    • Comparison to predicate devices: The bond strength of the device was compared to that of existing, legally marketed predicate devices.

    8. The Sample Size for the Training Set

    Not applicable. This device is a physical material (dental cement), not an AI algorithm. Therefore, there is no "training set" in the context of machine learning.

    9. How the Ground Truth for the Training Set was Established

    Not applicable, as there is no "training set" for this type of device.

    Ask a Question

    Ask a specific question about this device