Suture wing is intended for fixation of soft tissue to bone, using suture, in orthopedic surgery.
This product is used for orthopedic surgery, which soft tissue fix such as ligaments, tendons, and capsules to bone. The anchor and sutures is made of non-absorbable and consists of Driver Shaft for anchor insertion. This product is sterilized product and single use only.
Sterile bone anchor-all suture is supplied EO gas sterile state and it was packed in tyvek and PE film.
The provided text is a 510(k) premarket notification for a medical device called "Suture Wing." This document focuses on demonstrating substantial equivalence to a previously cleared device, not on proving that the device meets specific acceptance criteria based on a study involving AI or human readers.
Therefore, the information required to answer the prompt regarding acceptance criteria and a study proving the device meets those criteria (especially in the context of AI performance, human reader studies, and ground truth establishment) is NOT present in the provided document.
The document details non-clinical bench tests to verify design specifications and compliance with various standards related to materials, mechanical performance, sterilization, shelf-life, packaging, bacterial endotoxin, and pyrogenicity. It explicitly states: "Bench tests were conducted to verify that the subject device met all design specifications as was Substantially Equivalent (SE) to the predicate device."
It describes the comparison to a predicate device and a reference device, indicating similarities and minor differences in material (needle presence, which is addressed by the reference device) and product size, with the safety of these differences evaluated through bench testing.
In summary, this document is a regulatory submission for a physical medical device (Suture Wing) establishing substantial equivalence based on bench testing and comparison to predicates, not a study evaluating AI or human reader performance.
Ask a specific question about this device
(303 days)
The Suture Anchors - HTA Headless Titanium Anchor and ZIP Anchors are indicated to be used for suture or tissue fixation in the elbow, shoulder, hand, wrist, foot, ankle, knee, and hip. Specific indications are listed below:
Elbow: Biceps Tendon Reattachment, Ulnar or Radial Collateral Ligament Reconstruction
Shoulder: Rotator Cuff Repair, Bankart Repair, Biceps Tenodesis, Acromio-Clavicular Separation Repair, Deltoid Repair, Capsular Shift or Capsulolabral Reconstruction
Hand Wrist: Scapholunate Ligament Reconstruction of collateral ligaments, Repair of Flexor and Extensor Tendons at the PIP, DIP and MCP joints for all digits, digital tendon transfers, Carpal Ligament Reconstruction and Carpometacarpal joint arthroplasty (basal thumb joint arthroplasty)
Foot/Ankle: Lateral Stabilization, Medial Stabilization, Achilles Tendon Repair, Metatarsal Ligament Repair, Hallux Valgus reconstruction, digital tendon transfers, Mid-foot reconstruction
Knee: Medial Collateral Ligament Repair, Lateral Ligament Repair, Patellar Tendon Repair, Posterior Oblique Ligament Repair, Iliotibial Band Tenodesis
Hip: Capsular repair, acetabular labral repair.
The Suture Anchors, manufactured by GM dos Reis Indústria e Comércio Ltda, are anchor-type implants, and are composed of two groups of anchors, manufactured in Titanium Alloy (ASTM F136) and Ultra High Molecular Weight Polyethylene – UHMWPE (which are called ZIP Anchor), that is the same raw material of the suture. The anchors are made available preloaded in a disposable inserter device, composed of a metal rod and a polymeric cable. The implant and disposable inserter devices are unique products and cannot be sold separately.
Implants of the Suture Anchors - GM Reis are classified as surgically invasive, non-absorbable, and non-active implantable medical devices. In addition, the implants, as well as, the inserter device, are for single-use and sold in sterile form - supplied as a sterile kit for ethylene oxide (ETO) according to ISO 11135 - "Preview Sterilization of health-care products -- Ethylene oxide -- Requirements for the development, validation and routine control of a sterilization process for medical devices".
The Suture Anchors - GM Reis is composed of two different groups of anchors:
- HTA – Headless Titanium Anchor.
- Anchor Diameters: ø1,7 mm; ø2,2 mm; ø2,7 mm; ø3,5 mm and ø5,0 mm
- -ZIP Anchor.
- Ø0.9mm; Ø1.2mm; Ø1.5mm; Ø1.8mm; Ø1.9mm; Ø2.6mm.
This document is a 510(k) Premarket Notification from the FDA regarding "Suture Anchors - HTA Headless Titanium Anchor and ZIP Anchors." It details the device, its intended use, and a comparison to predicate devices, but it does not contain any information about acceptance criteria or a study proving the device meets those criteria for an AI/algorithmic device.
The document discusses non-clinical performance data for the suture anchors themselves (insertion torque, pullout strength, MRI compatibility) to demonstrate substantial equivalence to predicate devices, but this is for a physical medical device, not a software or AI-driven diagnostic or therapeutic tool.
Therefore, I cannot provide the requested information based on the provided text. The prompt asks for details about a study proving an AI/algorithmic device meets acceptance criteria, which is not what this FDA document is about.
Ask a specific question about this device