510(k) Data Aggregation

    K Number
    K012805
    Device Name
    AUTOMARQER
    Date Cleared
    2002-03-13

    (204 days)

    Product Code
    Regulation Number
    864.5220
    Reference & Predicate Devices
    Why did this record match?
    Device Name :

    AUTOMARQER

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The AutoMARQER™ is a differential spectrophotometer/reflectometer for sperm analysis and quantification, using MARQ™ Plus Test Kits.

    Device Description

    The AutoMARQER™ functions as a differential spectrophotometer / reflectometer, using MARQ™ Plus Test Kits* for sperm analysis. The AutoMARQER conducts sequential measurement operations on a specimen introduced into the instrument on a special MARQ™ Plus Test Kit cassette designed for use with the AutoMARQER. When using the FertilMARQ Plus Test Kit,* the AutoMARQER measures sperm concentration, motility and velocity. The AutoMARQER performs as a spectrophotometer when measuring specimen concentration. When measuring motility and velocity, it measures light scatter that occurs as sperm intercept its laser beam. It measures number of sperm in a beam directly by counting sperm cells crossing the beam and determines their velocity by the length of bearn passage. Since the beam diameter is known, the crossing time gives the sperm velocity

    AI/ML Overview

    Here's an analysis of the provided text regarding the acceptance criteria and supporting studies for the Hamilton Thorne Research AutoMARQER™ device:

    1. A table of acceptance criteria and the reported device performance:

    The provided document does not explicitly state numerical acceptance criteria. Instead, it makes a general claim regarding equivalence, which serves as the implicit performance standard.

    Acceptance Criteria (Implicit)Reported Device Performance
    Equivalent results to predicate device (IVOS™ Sperm analysis system)"Equivalent results are obtained on semen samples analyzed by both the AutoMARQER™ and the IVOS™ Sperm analysis system."

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective):

    The document does not specify the sample size used for the test set or the data provenance (country of origin, retrospective/prospective). It only states that "Equivalent results are obtained on semen samples...".

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience):

    This information is not provided in the document. The ground truth appears to be based on the results from the predicate device, the IVOS™ Sperm analysis system, rather than expert consensus on individual cases.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    This information is not provided in the document. Given that the comparison is to a predicate device, it's unlikely an adjudication method for human readers was used in this context.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    A multi-reader multi-case (MRMC) comparative effectiveness study with human readers assisting an AI (or vice-versa) was not done. This device is a standalone analytical instrument, not an AI-assisted diagnostic tool for human readers.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    Yes, a standalone performance evaluation was conducted. The AutoMARQER™ is described as functioning independently to measure sperm concentration, motility, and velocity. The performance test involved directly comparing its results to those of a legally marketed predicate device, the IVOS™ Sperm analysis system.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    The ground truth for the performance study was established by the legally marketed predicate device, the IVOS™ Sperm analysis system. The study's objective was to demonstrate "equivalent results" to this established device.

    8. The sample size for the training set:

    The document does not provide any information about a training set since the device is not described as utilizing a machine learning algorithm that requires explicit training data in the context of this 510(k) submission. It functions as a spectrophotometer/reflectometer.

    9. How the ground truth for the training set was established:

    This question is not applicable as the document does not indicate the use of a machine learning model requiring a training set or ground truth for such a set.

    Ask a Question

    Ask a specific question about this device

    K Number
    K990184
    Device Name
    AUTOMARQER
    Date Cleared
    1999-03-19

    (58 days)

    Product Code
    Regulation Number
    864.5220
    Reference & Predicate Devices
    Why did this record match?
    Device Name :

    AUTOMARQER

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Automarqer™ is a differential spectrophotometer for quantification of results using MARQTM Test Kits for sperm analysis.

    Device Description

    The Automarqer™ is a differential spectrophotometer for quantification of results for sperm analysis. The MARQ test kits employ a unique test cassette with four wells, each containing a filter to retain the test reagents and sample suspension. The test cassette is designed to be inserted into the Automarqer for reading of results after the sample has been processed. The Automarger provides the numeric analysis of the quantity of sperm or other sperm ejaculate component being evaluated.

    The Automarqer operates by measuring the well reflectivity in two wavelengths (red and green) and deriving the optical absorption in DNA-specific dyes within the wells, generated by the staining reagents used in the MARQ test kits. Each well emits a signal in the color with which it is illuminated (either red or blue dye). The first well of the test cassette provides a standard signal (using a standardized latex bead suspension), the second well provides a null signal, and the third and fourth wells provide sample signals.

    The Automarqer contains an optical assembly, microprocessor and program, cassette position sensor and readout screen. Software in the microprocessor ROM directs the operations. The microprocessor detects position of the cassette as each well is inserted, stores the value of the signal from each well separately under red and green wavelength illuminations, and computes the corresponding reflectivity of the sample, using the scale defined by the difference between the first two wells (the standard signal and the null signal). In this way, the system is self-calibrating on each cassette.

    AI/ML Overview

    Here is an analysis of the provided text regarding the Automarqer™ device, focusing on its acceptance criteria and the study proving it.

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly state formal "acceptance criteria" with numerical targets in the way typically seen in device submissions (e.g., "accuracy > 95%"). Instead, it describes performance in terms of variability and correlation to a predicate device. The implied acceptance criteria are that the device should have low internal variability and high correlation with the legally marketed predicate.

    Acceptance Criteria (Implied)Reported Device Performance
    Low variability due to equipment (Automarqer and cassette)Automarqer well variability: