Search Filters

Search Results

Found 124 results

510(k) Data Aggregation

    K Number
    K211320
    Device Name
    CAPRI Corpectomy Cage System
    Manufacturer
    K2M, Inc.
    Date Cleared
    2022-02-24

    (300 days)

    Product Code
    PLR, MQP
    Regulation Number
    888.3060
    Why did this record match?
    Applicant Name (Manufacturer) :

    K2M, Inc

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    CAPRI Corpectomy Cages are vertebral body replacement devices intended for use in the cervical and thoracolumbar spine. When used in the cervical spine (C2-T1), CAPRI Static and Expandable cages are intended for use in skeletally mature patients to replace a diseased or damaged vertebral body caused by tumor, fracture, or osteomyelitis, or for reconstruction following corpectomy performed to achieve decompression of the spinal cord and neural tissues in cervical degenerative disorders. These cages are intended to restore integrity of the spinal column even in the absence of fusion for a limited time period in patients with advanced stage tumors involving the cervical spine in whom life expectancy is of insufficient duration to permit achievement of fusion, with bone graft used at the surgeon's discretion. When used in the thoracolumbar spine (T1-L5), CAPRI Static and Expandable cages are intended for use to replace a collapsed, damaged, or unstable vertebral body due to tumor and trauma (i.e. fracture). These are designed to provide anterior spinal column support even in the absence of fusion for a prolonged period. The interior of the cages can be packed with autograft or allogenic bone graft comprising cancellous and/or corticocancellous bone graft as an adjunct to fusion. When used in the thoracolumbar spine, the CAPRI Static and Expandable Corpectomy cages are intended to be used with supplemental internal fixation appropriate for the implanted level, including K2M Pedicle Screw and Hook Systems, and K2M Spinal Plate Systems. When used in the cervical spine at one or two levels, the CAPRI Static and Expandable cages are intended to be used with supplemental fixation cleared by the FDA for use in the cervical spine. When used at more than two levels, supplemental fixation should include posterior fixation which is cleared by the FDA.
    Device Description
    The CAPRI Corpectomy System implants are vertebral body replacement devices that are designed in a variety of lengths, widths, and heights to match the patient's anatomy. Static (titanium) and expandable (titanium and cobalt chrome) cervical cages are available and are implanted via an anterior approach. The cervical implants of the CAPRI Corpectomy Cage Systems are manufactured from Titanium (per ASTM F3001 and ASTM 136) and Cobalt Chrome (per ASTM F1537). The purpose of this Traditional 510(k) submission is to introduce a new 12x14mm cervical expandable footprint size to the previously cleared CAPRI Corpectomy Cage System. Function: The system is used to provide structural stability in skeletally mature individuals following a corpectomy or vertebrectomy.
    Ask a Question
    K Number
    K202528
    Device Name
    Cannulated Power Driver Attachment
    Manufacturer
    K2M Inc.
    Date Cleared
    2020-10-26

    (55 days)

    Product Code
    NKB
    Regulation Number
    888.3070
    Why did this record match?
    Applicant Name (Manufacturer) :

    K2M Inc

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The MESA and DENALI Spinal Systems (including ARI Staples) and the EVEREST Spinal System are cleared for the following indications: Posterior non-cervical fixation as an adjunct to fusion for the following indications: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies); spondylolisthesis; trauma (i.e. fracture or dislocation); spinal stenosis; curvatures (i.e. scoliosis, kyphosis and/or lordosis); tumor; pseudoarthosis; and/or failed previous fusion. Except for hooks, when used as an anterolateral thoracic/lumbar system the Range Spinal System may also be used for the same indications as an adjunct to fusion. Except for the ARI staples, the MESA, DENALI and EVEREST Spinal Systems are indicated as an adjunct to fusion to treat adolescent idiopathic scoliosis when used for posterior non-cervical fixation in pediatric patients. The MESA, DENALI and EVEREST Spinal System for pediatric use is intended to be used with autograft and/or allograft. Pediatric pedicle screw fixation is limited to a posterior approach.
    Device Description
    This traditional 510(k) premarket notification is to introduce the Cannulated Power Driver Attachment instrument for use with Stryker Power Systems. The Cannulated Power Driver Attachment is an accessory to the Everest and Range (Mesa and Denali) pedicle screw systems intended to facilitate the insertion of pedicle screws using powered instrumentation. The Cannulated Power Driver Attachment, also referred to as the power adaptor or subject device, serves as a mechanical interface between the power driver and screwdriver instrument. When the adaptor is attached, the driver (corded and cordless) provides appropriate power to rotate screw drivers for the insertion of pedicle screws. No changes have been made to the indications for use of the associated thoracolumbar spinal implant systems Everest and Range (Mesa and Denali) Spinal Systems. The indications for use of each spinal system remain consistent with their most recent 510(k) clearance.
    Ask a Question
    K Number
    K201006
    Device Name
    K2M Navigation Instruments
    Manufacturer
    K2M, Inc.
    Date Cleared
    2020-08-07

    (112 days)

    Product Code
    OLO
    Regulation Number
    882.4560
    Why did this record match?
    Applicant Name (Manufacturer) :

    K2M, Inc

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    K2M Navigation Instruments are intended to be used in the preparation and placement of K2M screws (Denali, Mesa, Everest, and Yukon) during spinal surgery to assist the surgeon in precisely locating anatomical structures in either open or minimally invasive procedures. MESA screw navigation is intended for open procedures only. These instruments are designed for use with the Medtronic StealthStation® System, which is indicated for any medical condition in which the use of stereotactic surgery may be appropriate, and where reference to a rigid anatomical structure, such as a vertebra, can be identified relative to a CT or MR based model, fluoroscopy images, or digitized landmarks of the anatomy. Navigated Screw Inserters are also compatible with the Medtronic IPC POWEREASE System. The K2M Navigation Instruments are not intended for navigation of occipital screws.
    Device Description
    K2M Navigation Instruments are nonsterile, reusable surgical instruments (inserters, taps, probes, and awls) and single use drill bits intended be used when implanting previously cleared components of Mesa, Denali, Everest, and Yukon Spine Systems. These instruments are designed to interface with the Medtronic StealthStation® System when used for navigation during cervical and thoracolumbar spinal surgery.
    Ask a Question
    K Number
    K193203
    Device Name
    MOJAVE Expandable Interbody System
    Manufacturer
    K2M, Inc.
    Date Cleared
    2020-02-18

    (90 days)

    Product Code
    MAX
    Regulation Number
    888.3080
    Why did this record match?
    Applicant Name (Manufacturer) :

    K2M, Inc

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The MOJAVE Expandable Interbody System implants are intervertebral body fusion devices indicated for use with autograft and/or allogenic bone graft comprised of cancellous bone graft when used as an adjunct to fusion in patients with degenerative disc disease (DOD) at one level or two contiguous levels from L2 to S1. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). These patients should be skeletally mature and have six months of nonoperative therapy. Additionally, the MOJAVE lumbar implants can be used as an adjunct to fusion in patients diagnosed with degenerative scoliosis. MOJAVE lumbar implants are intended to be used with supplemental spinal fixation systems that have been cleared for use in the lumbosacral spine.
    Device Description
    The MOJAVE Expandable Interbody System is comprised of expandable titanium implants designed to allow for intraoperative adjustment to aid the surgeon in matching implant fit to the vertebral anatomy in the lumbar spine. The implants have titanium endplates designed to allow for bone ingrowth and engagement with the vertebral body end plates. The implants are manufactured from medical grade titanium alloy (ASTM F1472, ASTM F136, ASTM F3001) and cobalt chromium alloy (ASTM F1537) and are available in a variety of heights to accommodate anatomical variations.
    Ask a Question
    K Number
    K193129
    Device Name
    Yukon OCT Spinal System
    Manufacturer
    K2M, Inc.
    Date Cleared
    2020-02-07

    (87 days)

    Product Code
    NKG, KWP
    Regulation Number
    888.3075
    Why did this record match?
    Applicant Name (Manufacturer) :

    K2M, Inc

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The YUKON OCT Spinal System is intended to provide immobilization of spinal segments as an adjunct to fusion for the following acute and chronic instabilities of the craniocervical junction, the cervical spine (C1 to C7) and the thoracic spine (T1-T3); traumatic spinal fractures and/or traumatic dislocations; instability or deformity; failed previous fusion (e.g., pseudoarthrosis); tumors involving the cervical spine; and degenerative disease, including intractable radiculopathy and/or myelopathy, neck and/or arm pain of discogenic origin as confirmed by radiographic studies, and degenerative disease of the facets with instability. The YUKON OCT Spinal System is also intended to restore the integrity of the spinal column even in the absences of fusion for a limited time period in patients with advanced stage tumors involving the cervical spine in whom life expectancy is of insufficient duration to permit achievement of fusion. In order to achieve additional levels of fixation, the YUKON OCT Spinal System may be connected to EVEREST, MESA, and DENALI Spinal System components via the rod to rod connectors or transition rods.
    Device Description
    The YUKON OCT Spinal System is a top-loading, multiple component, posterior (occipital-cervical-thoracic) spinal fixation system consisting of screws, hooks, rods, rod connectors, and occipital components. The system functions as an adjunct to fusion to provide stablilization of the posterior cervical and thoracic spine.
    Ask a Question
    K Number
    K192911
    Device Name
    Brainlab Compatible K2M Navigation Instruments
    Manufacturer
    K2M, Inc.
    Date Cleared
    2019-11-14

    (30 days)

    Product Code
    OLO
    Regulation Number
    882.4560
    Why did this record match?
    Applicant Name (Manufacturer) :

    K2M, Inc

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    Brainlab Compatible K2M Navigation Instruments are intended to be used in the preparation and placement of K2M pedicle screws (DENALI, MESA, EVEREST, YUKON) during spinal surgery to assist the surgeon in precisely locating anatomical structures in either open or minimally invasive procedures. These instruments are designed for use with the Brainlab Navigation system, which is indicated for any medical condition in which the use of stereotactic surgery may be appropriate, and where reference to a rigid anatomical structure, such as a skull, a long bone, or vertebra, can be identified relative to a CT or MR based model, fluoroscopy images, or digitized landmarks of the anatomy. The Brainlab Compatible K2M Navigation Instruments are not intended for navigation of occipital screws.
    Device Description
    Brainlab Compatible K2M Navigation Instruments are manual surgical instruments intended be used when implanting previously cleared components of MESA, DENALI, EVEREST and YUKON Spinal Systems. These instruments are designed to interface with the Brainlab Navigation system when used for navigation during spinal surgery. The subject instruments feature a modification of the connection mechanism geometry and material to enhance user experience.
    Ask a Question
    K Number
    K190179
    Device Name
    SAHARA Stabilization System
    Manufacturer
    K2M, Inc.
    Date Cleared
    2019-10-03

    (244 days)

    Product Code
    OVD, MAX
    Regulation Number
    888.3080
    Why did this record match?
    Applicant Name (Manufacturer) :

    K2M, Inc

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The SAHARA Stabilization System implants are intervertebral body fusion devices indicated for use with autograft and/or allogenic bone graft comprised of cancellous and/or corticocancellous bone graft when used as an adjunct to fusion in patients with degenerative disc disease (DDD) at one level or two contiguous levels from L2 to S1. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade 1 spondylolisthesis or retrolisthesis at the involved level(s). These patients should be skeletally mature and have six months of nonoperative therapy. Additionally, the SAHARA implants can be used as an adjunct to fusion in patients diagnosed with degenerative scoliosis Hyperlordotic (angles > 15°) and Lateral implants must be used with supplemental fixation (i.e., posterior pedicle screw and rod system) cleared for use in the lumbar spine, in addition to the bone screws provided. Additional supplemental fixation (i.e. pedicle screw and rod system) is needed when used as an adjunct to fusion for degenerative scoliosis. Otherwise, the Sahara Stabilization System implants may be used as a stand-alone device, which is intended to be used with the bone screws provided.
    Device Description
    The subject of this 510(k) submission is the addition of lateral implants to the previously cleared SAHARA Stabilization System. The implants function as an expandable intervertebral body fusion device to provide support and stabilization to the lumbar segments of the spine through a lateral approach. The system includes lateral interbody devices as well as bone screws for integrated fixation. The implants are manufactured from Titanium (ASTM F67), Titanium Alloy (ASTM F136, ASTM F1472, ASTM F3001) and Cobalt Chrome (ASTM F1537). The implants contain components that are additively manufactured.
    Ask a Question
    K Number
    K190584
    Device Name
    CAYMAN LP Plate System
    Manufacturer
    K2m, Inc.
    Date Cleared
    2019-05-15

    (70 days)

    Product Code
    KWQ
    Regulation Number
    888.3060
    Why did this record match?
    Applicant Name (Manufacturer) :

    K2m, Inc

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The CAYMAN LP Plate System is intended for use in spinal fusion procedures as a means to maintain the relative position of weak bony tissue such as allografts or autografts. The device is not intended for load bearing indications.
    Device Description
    The CAYMAN LP Plate System are non-load bearing devices, each consisting of a plate and screw for attachment to the vertebral body. The plates are designed to be used as additions to spinal fusion procedures from the lateral and anterior approaches, forming a preventative barrier to intervertebral cage movement. Materials: The devices are manufactured from Ti6Al4V per ASTM and ISO standards. Function: The plates are designed to be used in a spinal fusion procedures to provide stabilization and buttressing of tissue in the intervertebral space.
    Ask a Question
    K Number
    K182473
    Device Name
    PYRENEES Cervical Plate System, BLUE RIDGE Cervical Plate System, OZARK Cervical Plate System, CAYMAN Thoracolumbar and Buttress Plate Systems
    Manufacturer
    K2M Inc.
    Date Cleared
    2018-12-12

    (93 days)

    Product Code
    KWQ
    Regulation Number
    888.3060
    Why did this record match?
    Applicant Name (Manufacturer) :

    K2M Inc

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    PYRENEES and BLUE RIDGE Cervical Plate Systems are indicated for use in anterior screw fixation to the cervical spine (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (including fractures), spinal stenosis and tumors (primary and metastatic), failed previous fusions (pseudarthrosis) and deformity (defined as scoliosis, kyphosis or lordosis). OZARK Cervical Plate System is indicated for use in anterior screw fixation to the cervical spine (C2-T1) for the following indications: degenerative disc disease (DDD) (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (including fractures), spinal stenosis and tumors (primary and metastatic), failed previous fusions (pseudarthrosis) and deformity (defined as scoliosis, kyphosis or lordosis). The CAYMAN Buttress Plates are intended for use in spinal fusion procedures as a means to maintain the relative position of weak bony tissue such as allografts or autografts. The device is not intended for load bearing indications. The CAYMAN Thoracolumbar Plates are indicated for use via the lateral or anterolateral surgical approach in the treatment of thoracic and thoracolumbar (T1-L5) spine and for use as an anteriorly placed supplemental fixation device for the lumbosacral level below the bifurcation of the vascular structures (L5-S1). The Cayman Thoracolumbar Plate System is intended to provide temporary stabilization during fusion using autograph or allograft in skeletally mature patients in the treatment of the following acute and chronic instabilities and deformities: a) degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), b) pseudoarthrosis, c) spondylolysis, d) spondylolisthesis, e) fracture, f) neoplastic disease, g) unsuccessful previous fusion surgery, h) lordotic deformities of the spine, i) thoracolumbar or lumbar scoliosis, j) deformity (i.e., scoliosis, kyphosis, and/or lordosis) associated with deficient posterior elements such as that resulting from laminectomy.
    Device Description
    The previously cleared K2M PYRENEES, BLUE RIDGE, OZARK and CAYMAN plate systems consist of a variety of plates and screws designed to provide support across implanted levels of the cervical, thoracolumbar and lumbosacral spine until fusion is achieved. The primary purpose of this submission is to establish an MR Conditional labeling claim for these implants. In addition, PYRENEES, BLUE RIDGE and CAYMAN components that were previously provided non-sterile are now being optionally offered as sterile packaged devices.
    Ask a Question
    K Number
    K180665
    Device Name
    SANTORINI Corpectomy Cage System, CAPRI Corpectomy Cage System
    Manufacturer
    K2M, LLC.
    Date Cleared
    2018-11-28

    (259 days)

    Product Code
    MQP, PLR
    Regulation Number
    888.3060
    Why did this record match?
    Applicant Name (Manufacturer) :

    K2M, LLC

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    SANTORINI Corpectomy Cages are vertebral body replacement devices intended for use in the cervical and thoracolumbar spine. When used in the cervical spine (C2-T1), SANTORINI cages are intended for use in skeletally mature patients to replace a diseased or damaged vertebral body caused by tumor, fracture, or osteomyelitis, or for reconstruction following corpectomy performed to achieve decompression of the spinal cord and neural tissues in cervical degenerative disorders. These cages are intended to restore integrity of the spinal column even in the absence of fusion for a limited time period in patients with advanced stage tumors involving the cervical spine in whom life expectancy is of insufficient duration to permit achievement of fusion, with bone graft used at the surgeon's discretion. When used in the thoracolumbar spine (T1-L5), SANTORINI cages are intended for use to replace a collapsed, damaged, or unstable vertebral body due to tumor and trauma (i.e. fracture). These cages are designed to provide anterior spinal column support even in the absence of fusion for a prolonged period. The interior of the cages can be packed with autograft or allogenic bone graft comprising cancellous and/or corticocancellous bone graft as an adjunct to fusion. When used in the thoracolumbar spine, the Santorini Corpectomy cages are intended to be used with supplemental internal fixation appropriate for the implanted level, including K2M Pedicle Screw and Hook Systems, and K2M Spinal Plate Systems. When used in the cervical spine at one or two levels, the SANTORINI Corpectomy Cage System is intended to be used with supplemental fixation cleared by the FDA for use in the cervical spine. When used at more than two levels, supplemental fixation should include posterior fixation which is cleared by the FDA CAPRI Corpectomy Cages are vertebral body replacement devices intended for use in the cervical and thoracolumbar spine. When used in the cervical spine (C2-T1). CAPRI Static cages are intended for use in skeletally mature patients to replace a diseased or damaged vertebral body caused by tumor, fracture, or osteomyelitis, or for reconstruction following corpectomy performed to achieve decompression of the spinal cord and neural tissues in cervical degenerative disorders. These cages are intended to restore integrity of the spinal column even in the absence of fusion for a limited time period in patients with advanced stage tumors involving the cervical spine in whom life expectancy is of insufficient duration to permit achievement of fusion, with bone graft used at the surgeon's discretion. When used in the thoracolumbar spine (T1-L5), CAPRI Static and Expandable cages are intended for use to replace a collapsed, damaged, or unstable vertebral body due to tumor and trauma (i.e. fracture). These cages are designed to provide anterior spinal column support even in the absence of fusion for a prolonged period. The interior of the cages can be packed with autograft or allogenic bone graft comprising cancellous and/or corticocancellous bone graft as an adjunct to fusion. When used in the thoracolumbar spine, the CAPRI Static and Expandable Corpectomy cages are intended to be used with supplemental internal fixation appropriate for the implanted level, including K2M Pedicle Screw and Hook Systems, and K2M Spinal Plate Systems. When used in the cervical spine at one or two levels, the CAPRI Static cages are intended to be used with supplemental fixation cleared by the FDA for use in the cervical spine. When used at more than two levels, supplemental fixation should include posterior fixation which is cleared by the FDA
    Device Description
    The SANTORINI and CAPRI Corpectomy System implants are vertebral body replacement devices that are designed in a variety of lengths, widths and heights to match the patient's anatomy. Solid and adjustable cages are available and can be implanted via posterior, anterior or lateral approaches. The implants of the CAPRI Corpectomy Cage Systems are manufactured from Titanium (per ASTM F3001) and Cobalt Chrome (per ASTM F1537). The SANTORINI implants are made from PEEK OPTIMA LT1 (ASTM F2026) and tantalum (ASTM 560), with some components containing CP titanium (ASTM F67). The purpose of this submission is to expand the indications to include the cervical spine. Function: The system is used to provide structural stability in skeletally mature individuals following a corpectomy or vertebrectomy.
    Ask a Question