Search Results
Found 19 results
510(k) Data Aggregation
K Number
K142415Device Name
Hi-Torque JET Guide Wire Family
Manufacturer
ABBOTT VASCULAR INC.
Date Cleared
2014-12-19
(113 days)
Product Code
DQX
Regulation Number
870.1330Why did this record match?
Applicant Name (Manufacturer) :
ABBOTT VASCULAR INC.
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
This HI-TORQUE guide wire is intended to facilitate the delivery of catheter-based interventional devices during percutaneous transluminal coronary angioplasty (PTCA). This guide wire may also be used with compatible stent devices during therapeutic procedures.
The guide wire may also be used to reach and cross a target lesion, provide a pathway within the vessel structure, facilitate the substitution of one diagnostic or interventional device for another, and to distinguish the vasculature.
Device Description
The Abbott Vascular 0.014" Hi-Torque Jet (HT Jet) Guide Wire with hydrophilic and hydrophobic coatings is a stainless steel and nitinol steerable guide wire with a maximum diameter of 0.0145", provided in 190 cm extendable, 250 cm, and 300 cm exchange lengths. The distal tip has a radiopaque length of 3.0 cm. The distal tip is straight and shapeable. The HT Jet Guide Wire Family consists of two models with differing flexibility and performance: the HT Jet 15C and the HT Jet 25C. The proximal end of the 190 cm model is plunge ground and coined to fit into the hypotube portion of the DOC® Guide Wire Extension. The HT Jet guide wire family is compatible with devices designed for use with 0.014" guide wires.
Ask a Question
K Number
K123067Device Name
PROGRESS GUIDE WIRE FAMILY, PILOT GUIDE WIRE FAMILY
Manufacturer
ABBOTT VASCULAR INC.
Date Cleared
2013-01-29
(120 days)
Product Code
DQX
Regulation Number
870.1330Why did this record match?
Applicant Name (Manufacturer) :
ABBOTT VASCULAR INC.
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
Intended to facilitate the delivery of catheter-based interventional devices during percutaneous transluminal coronary angioplasty (PTCA) and percutaneous transluminal angioplasty (PTA). This guide wire may be used with compatible stent devices during therapeutic procedures. The guide wire may be used to reach and cross a target lesion, provide a pathway within the vessel structure, facilitate the substitution of one diagnostic or interventional device for another, and to distinguish the vasculature. This guide wire may also be used to cross or assist in crossing de novo chronic total coronary occlusions (CTO).
Device Description
The HI-TOROUE PROGRESS Guide Wire (K091825, cleared Sept. 25, 2009) is an existing family of guide wires, designed to provide improved torque response and crossing while maintaining tactile feedback in stenotic vessels. The subject wire is a core to tip design, where the core material runs through the entire length of the wire. This family of guide wires has a maximum diameter of 0.0140" with a stainless steel core and is provided in 190cm extendable and 300cm exchange lengths. The distal core segment of the PROGRESS guide wire family is offered in 5 configurations: PROGRESS 40. PROGRESS 80, PROGRESS 120, PROGRESS 140T and PROGRESS 200T. Each configuration is identical in design except for those design features that impact tip stiffness.
The HI-TOROUE PILOT Guide Wire (K030549/K101116, originally cleared Mav 14, 2003) is an existing family of guide wires constructed using a 304V stainless steel core. HI-TORQUE PILOT Guide Wires have a maximum diameter of 0.0140" and are available in 190cm extendable lengths and a 300 cm exchange length. There are three HI-TORQUE PILOT™ Guide Wire designs with varying tip stiffness (i.e., HI-TORQUE PILOT™ 50, HI-TORQUE PILOT™ 150, and HI-TOROUE PILOT™ 200 Guide Wires). The distal segment of the guide wire includes a series of tapered grinds and a flat section, which reduce the diameter and stiffness of the distal core, thus yielding the desired flexibility and performance.
Ask a Question
K Number
K122573Device Name
HI-TORQUE COMMAND GUIDE WIRE FAMILY
Manufacturer
ABBOTT VASCULAR INC.
Date Cleared
2012-11-20
(89 days)
Product Code
DQX
Regulation Number
870.1330Why did this record match?
Applicant Name (Manufacturer) :
ABBOTT VASCULAR INC.
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
This Hi-Torque Guide Wire is intended to facilitate the placement of balloon dilatation catheters during percutaneous transluminal angioplasty (PTA), in arteries such as the femoral, popliteal and infra-popliteal arteries. This guide wire may also be used with compatible stent devices during therapeutic procedures.
The guide wire may also be used to reach and cross a target lesion, provide a pathway within a vessel structure, facilitate the substitution of one diagnostic or interventional device for another, and to distinguish the vasculature.
Device Description
The Abbott Vascular 0.014" Hi-Torque Command (HT Command) Guide Wire with hydrophilic and hydrophobic coatings is a stainless steel and nitinol steerable guide wire with a maximum diameter of 0.0145", provided in 190 cm extendable, 250 cm, and 300 cm exchange lengths. The distal tip has a radiopaque length of 3.0 cm. The distal tip is straight and shapeable. The HT Command Guide Wire Family consists of two models with differing flexibility and performance; the HT Command and the HT Command ES. The proximal end of the 190 cm model is plunge ground and coined to fit into the hypotube portion of the DOC® Guide Wire Extension. The HT Command guide wire family is compatible with devices designed for use with 0.014" guide wires.
Ask a Question
K Number
K102705Device Name
ARMADA 14 PTA CATHETER
Manufacturer
ABBOTT VASCULAR INC.
Date Cleared
2010-12-07
(78 days)
Product Code
LIT, DQY
Regulation Number
870.1250Why did this record match?
Applicant Name (Manufacturer) :
ABBOTT VASCULAR INC.
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The device is indicated to dilate stenoses in femoral, popliteal, infra popliteal and renal arteries and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. The 2.0 to 4.0 mm balloon diameters are also indicated for postdilatation of balloon-expandable stents up to 40 mm and self-expanding stents up to 80 mm in the vessels listed above.
Device Description
The Armada 14 PTA Catheter is a standard over-the-wire (OTW) balloon catheter to be used for percutaneous transluminal angioplasty (PTA). It is available in balloon lengths of 20 mm to 200 mm, with nominal diameters of 1.5 mm to 4.0 mm. The balloon has a nominal diameter inflation pressure of 8 atm and a rated burst pressure of 14 atm. Two polymer marker bands mark the working length of the balloons. The catheter shaft has working lengths of 90 and 150 cm. The inner lumen will accept a 0.014" guide wire. The outer shaft has a polycarbonate y-arm fuer adhesively bonded to the proximal end to allow for entry to the guide wire lumen and to allow for connection of the inflation device to the inflation/deflation lumen.
Ask a Question
K Number
K101648Device Name
HI-TORQUE WINN GUIDE WIRE FAMILY
Manufacturer
ABBOTT VASCULAR INC.
Date Cleared
2010-07-08
(27 days)
Product Code
DQX
Regulation Number
870.1330Why did this record match?
Applicant Name (Manufacturer) :
ABBOTT VASCULAR INC.
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
This Hi-Torque guide wire is intended to facilitate the placement of balloon dilatation catheters during percutaneous transluminal coronary angioplasty (PTCA) and percutaneous transluminal angioplasty (PTA). This guide wire may also be used with compatible stent devices during therapeutic procedures.
Device Description
The Hi-Torque Winn Guide Wire Family is a family of guide wires, designed to provide improved torque response and crossing while maintaining tactile feedback in stenotic vessels. The subject wire is a core to tip design, where the core material runs through the entire length of the wire. This family of guide wires have a maximum diameter of 0.0140" with a stainless steel core and are provided in 190 cm extendable and 300 cm exchange lengths. The distal core segment of the Winn is offered in 5 configurations: Winn 40. Winn 80. Winn 120, Winn 140T and Winn 200T. Each configuration is identical in design except for those design features that impact tip stiffness.
Ask a Question
K Number
K101011Device Name
HI-TORQUE BALANCE MIDDLEWEIGHT UNIVERSAL
Manufacturer
ABBOTT VASCULAR INC.
Date Cleared
2010-05-24
(42 days)
Product Code
DQX
Regulation Number
870.1330Why did this record match?
Applicant Name (Manufacturer) :
ABBOTT VASCULAR INC.
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
To facilitate the placement of balloon dilatation catheters during percutaneous transluminal coronary angioplasty (PTCA) and percutaneous transluminal angioplasty (PTA). The wire is also intended to facilitate the placement of compatible stent devices during therapeutic intravascular procedures.
Device Description
The HI-TORQUE BALANCE MIDDLEWEIGHT™ UNIVERSAL Guide Wire is a steerable guide wire available in a maximum diameter of 0.0137" and in lengths of 190 cm and 300 cm. The distal segment of the guide wire, up to the hypotube, is coated with hydrophilic coating to reduce friction for improved guide wire movement within the catheter. The distal tip is offered in a straight shapeable configuration and a pre-shaped "J" configuration. The proximal core has a maximum diameter of 0.0137". The proximal end of the guide wire is coated with PTFE, which reduces friction of the wire within a catheter. The BMW™ Universal Guide Wire is DOC® extendable in the 190 cm lengths.
Ask a Question
K Number
K091825Device Name
HI-TORQUE PROGRESS GUIDE WIRE FAMILY
Manufacturer
ABBOTT VASCULAR INC.
Date Cleared
2009-09-25
(98 days)
Product Code
DQX, DOX
Regulation Number
870.1330Why did this record match?
Applicant Name (Manufacturer) :
ABBOTT VASCULAR INC.
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
This HI-TORQUE guide wire is intended to facilitate the placement of balloon dilatation catheters during percutaneous transluminal coronary angioplasty (PTCA) and percutaneous transluminal angioplasty (PTA). This guide wire may also be used with compatible stent devices during therapeutic procedures.
Device Description
The HI-TORQUE PROGRESS Guide Wire Family is a new family of guide wires. designed to provide improved torque response and crossing while maintaining tactile feedback in stenotic vessels. The subject wire is a core to tip design, where the core material runs through the entire length of the wire. This family of guide wires have a maximum diameter of 0.0140" with a stainless steel core and are provided in 190cm extendable and 300cm exchange lengths. The distal core segment of the PROGRESS is offered in 5 configurations: PROGRESS 40, PROGRESS 80, PROGRESS 120, PROGRESS 140T and PROGRESS 200T. Each configuration is identical in design except for those design features that impact tip stiffness.
Ask a Question
K Number
K081417Device Name
FOXCROSS PTA CATHETER
Manufacturer
ABBOTT VASCULAR INC.
Date Cleared
2008-06-04
(15 days)
Product Code
LIT
Regulation Number
870.1250Why did this record match?
Applicant Name (Manufacturer) :
ABBOTT VASCULAR INC.
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The FoxCross PTA Catheter is intended for dilatation of lesions in the femoral, renal, iliac, popliteal, peroneal, and profunda arteries and native or synthetic arteriovenous dialysis fistulae. This catheter is not intended for the expansion or delivery of stents.
Device Description
The FoxCross PTA Catheter is a standard over-the-wire PTA catheter. The double lumen catheter has a balloon located near the distal tip. One lumen is used for inflation of the balloon, while the second lumen allows access to the distal tip of the catheter for guide wire insertion (max 0.035"). The balloon has two radiopaque markers for positioning the balloon relative to the stenosis. The balloon material expands to a known diameter at specific pressures.
Ask a Question
K Number
K080925Device Name
FOX PLUS PTA CATHETER
Manufacturer
ABBOTT VASCULAR INC.
Date Cleared
2008-04-28
(26 days)
Product Code
LIT, MAR
Regulation Number
870.1250Why did this record match?
Applicant Name (Manufacturer) :
ABBOTT VASCULAR INC.
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The Fox Plus PTA Catheter is intended for dilatation of lesions in the femoral, renal, iliac, popliteal, peroneal and profunda arteries and native or synthetic arteriovenous dialysis fistulae. This catheter is not intended for the expansion or delivery of stents.
Device Description
The Fox Plus PTA Catheter is a standard over-the-wire PTA catheter. The double lumen catheter has a balloon located near the distal tip. One lumen is used for inflation of the balloon, while the second lumen allows access to the distal tip of the catheter for guidewire insertion (max 0.035"). The balloon has two radiopaque markers for positioning the balloon relative to the stenosis. The balloon material expands to a known diameter at specific pressures.
Ask a Question
K Number
K063481Device Name
MODIFICATION TO RX HERCULINK ELITE BILIARY STENT SYSTEM
Manufacturer
ABBOTT VASCULAR INC.
Date Cleared
2007-09-14
(301 days)
Product Code
FGE
Regulation Number
876.5010Why did this record match?
Applicant Name (Manufacturer) :
ABBOTT VASCULAR INC.
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The RX Herculink® Elite™ Biliary Stent System is intended for palliation of malignant strictures in the biliary tree.
Device Description
The modified RX Herculink Elite Biliary Stent System includes:
- . A balloon expandable L605 cobalt chromium alloy stent pre-mounted on the balloon of a rapid exchange (RX) stent delivery system;
- Two radiopaque markers located underneath the balloon which identify the stent . position and fluoroscopically mark the working length of the balloon;
- . Proximal shaft markers to aid with delivery catheter position, relative to a biliary guiding catheter tip;
- A third marker located approximately 30 cm from the center of the balloon that aids in locating the guide wire exit lumen and facilitating catheter removal and exchange.
The delivery system can be utilized to optimize the stent wall apposition post stent deployment.
Ask a Question
Page 1 of 2