K Number
K090369
Date Cleared
2009-02-27

(14 days)

Product Code
Regulation Number
872.4200
Panel
Dental
Reference & Predicate Devices
Predicate For
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

To be used in the dental operatory to prepare dental cavities for restorations such as fillings, and for cleaning teeth.

Device Description

The ProDrive line of high-speed air-driven dental handpieces includes two models - the ProDrive Mini and ProDrive Standard. These models are each available with one of a variety of quick couplings for use with: Sirona, KaVo, W&H, Bien-Air, NSK Mach and NSK QD-J connections. In addition, the PD Standard model comes in a fixed coupling format for MidWest handpiece users. The handpieces come supplied with a halogen light source of approximately 25,000 lux and a 3 jet spray for water. Every ProDrive handpiece is equipped with the previously-cleared ProDrive turbine as the standard drive mechanism. The ProDrive turbine is appropriate for use with ProDrive carbide and diamond cutting instruments. A push-button spindle mechanism is used to grip the shanks of the cutting instruments. The unique geometry of the bur shank and turbine spindle securely locks the bur in the turbine eliminating the slipping that can occur over time with traditional burs and turbines. In addition to improved performance and durability, the secure locking mechanism enhances the safety of the ProDrive Replacement Turbine by reducing the risk of accidental disengagement of burs from the handpiece during operation. In addition, the ProDrive system incorporates the ability to index the bur to a second, extended, position effectively improving on the visibility angle and the utility of the handpiece without adversely affecting its performance.

AI/ML Overview

The provided document is a 510(k) Summary for a dental handpiece. It describes the device, its intended use, and a comparison to a predicate device. However, it does not include detailed study results, acceptance criteria with reported performance, or specific information about ground truth establishment, expert adjudication, or sample sizes for testing or training sets in the way that would typically be presented for a diagnostic AI/ML device.

The document primarily focuses on demonstrating substantial equivalence to a predicate device based on technological characteristics and adherence to performance standards for mechanical devices.

Therefore, many of the requested fields cannot be filled from the provided text.

Here's what can be extracted and what cannot:

1. Table of Acceptance Criteria and Reported Device Performance
The document states: "The ProDrive line of dental handpieces meets or exceeds all of the applicable performances standards outlined in ISO 7785-1:1997(E). Extensive testing indicates that after 250 sterilization/use cycles the ProDrive handpiece continues to meet all performance requirements."

This is a general statement rather than a table with specific criteria and numerical performance results. Without the actual ISO 7785-1:1997(E) document, the specific acceptance criteria cannot be listed. The reported performance is a qualitative statement of meeting/exceeding standards after 250 cycles.

Acceptance Criteria (from ISO 7785-1:1997(E))Reported Device Performance
Specific performance requirements as outlined in ISO 7785-1:1997(E) for dental handpieces.Meets or exceeds all applicable performance standards outlined in ISO 7785-1:1997(E) after 250 sterilization/use cycles.

2. Sample size used for the test set and the data provenance
Not explicitly stated. The document mentions "Extensive testing," but does not provide details on sample size or data provenance.

3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts
This is not applicable as this is a mechanical device, not a diagnostic device requiring expert interpretation for ground truth.

4. Adjudication method for the test set
Not applicable.

5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
Not applicable. This is a mechanical device, not an AI/ML-driven diagnostic tool.

6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done
Not applicable. This is a mechanical device.

7. The type of ground truth used
For this type of mechanical device, "ground truth" would relate to objective performance metrics measured against engineering specifications and international standards (ISO 7785-1:1997(E)). It's not about clinical diagnostic ground truth like pathology or expert consensus.

8. The sample size for the training set
Not applicable. There is no AI/ML model for which a "training set" would be used.

9. How the ground truth for the training set was established
Not applicable.

{0}------------------------------------------------

Image /page/0/Picture/0 description: The image shows the logo for Prodrive Systems. The logo features the word "PRODRIVE" in bold, sans-serif font, with a circle containing a dot in place of the letter "O". Below the word "PRODRIVE" is the word "SYSTEMS" in a smaller, sans-serif font.

一: -

KD90369

510(k) SUMMARY

ProDrive Line of Dental Handpieces ProDrive Systems Inc.

FEB 2 7 2009

Owned by:

ProDrive Systems Inc. 812 Commerce Drive Ogdensburg, NY 13669 USA

Contact Person:

Timothy F. Nason, PhD Director of Regulatory Affairs ProDrive Systems Inc. 812 Commerce Drive Ogdensburg, NY 13669 USA

Date of Summary:

January 9, 2009

Device Name:

Proprietary Name: Common Name: Classification Name: Product Code:

ProDrive Line of Dental Handpieces dental handpiece Handpiece, Air-powered, Dental EFB ("Dental handpiece and accessories", 21CFR 872.4200)

Predicate Device:

Proprietary Name: 510(k) Number: Product Code:

T1 LINE Dental Handpieces K972436 EFB

5

{1}------------------------------------------------

Description of Device:

The ProDrive line of high-speed air-driven dental handpieces includes two models - the ProDrive Mini and ProDrive Standard. These models are each available with one of a variety of quick couplings for use with: Sirona, KaVo, W&H, Bien-Air, NSK Mach and NSK QD-J connections. In addition, the PD Standard model comes in a fixed coupling format for MidWest handpiece users.

The handpieces come supplied with a halogen light source of approximately 25,000 lux and a 3 jet spray for water. Every ProDrive handpiece is equipped with the previously-cleared ProDrive turbine as the standard drive mechanism.

The ProDrive turbine is appropriate for use with ProDrive carbide and diamond cutting instruments. A push-button spindle mechanism is used to grip the shanks of the cutting instruments. The unique geometry of the bur shank and turbine spindle securely locks the bur in the turbine eliminating the slipping that can occur over time with traditional burs and turbines. In addition to improved performance and durability, the secure locking mechanism enhances the safety of the ProDrive Replacement Turbine by reducing the risk of accidental disengagement of burs from the handpiece during operation.

In addition, the ProDrive system incorporates the ability to index the bur to a second, extended, position effectively improving on the visibility angle and the utility of the handpiece without adversely affecting its performance.

The ProDrive line of dental handpieces meets or exceeds all of the applicable performances standards outlined in ISO 7785-1:1997(E). Extensive testing indicates that after 250 sterilization/use cycles the ProDrive handpiece continues to meet all performance requirements.

Intended Use of Device:

The ProDrive Line of Dental Handpieces is intended for use by authorized persons in the practice of dentistry. The intended use of the ProDrive Line of Dental Handpieces is identical to that of the Predicate Device.

{2}------------------------------------------------

Image /page/2/Picture/0 description: The image shows the logo for Prodrive Systems. The logo consists of the word "PRODRIVE" in bold, block letters, with a circle containing a stylized design in place of the "O". Below the word "PRODRIVE" is the word "SYSTEMS" in smaller, sans-serif letters. The text "Harness Performance through Innovation" is below the logo in a smaller font.

Comparison of Technological Characteristics to Predicate Device:

The following table compares the features of the ProDrive Line of Dental Handpieces to the Predicate Device:

TECHNOLOGICAL CHARACTERISTICCOMPARISON TO PREDICATE
Intended useIdentical
Indications for useIdentical
Target populationIdentical
Anatomical sitesIdentical
Where usedIdentical
Energy used and/or deliveredSimilar
Human factorsSimilar
DesignSimilar
PerformanceSimilar
Standards metIdentical
MaterialsSimilar
BiocompatibilityIdentical
Compatibility with environment and other devicesIdentical
SterilityIdentical
Electrical safetyIdentical
Mechanical safetyIdentical
Chemical SafetyIdentical
Thermal safetyIdentical
Radiation safetyIdentical

Table 1: Substantial Equivalence Table

Conclusions Drawn from Technical Comparison:

The ProDrive Line of Dental handpieces is essentially the same as the predicate device in terms of its intended use, operating principles and materials.

The ProDrive Line of Dental handpieces conforms to the ISO 7785-1:1997(E) standard and the FDA Guidance Document on Dental Handpieces.

Therefore, we conclude that the ProDrive Line of Dental handpieces is both safe and effective for its intended use.

{3}------------------------------------------------

Public Health Service

Image /page/3/Picture/2 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES . USA" arranged around the perimeter. Inside the circle is a stylized image of an eagle with its wings outstretched.

APR 23 2009

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

ProDrive Systems, Incorporated C/0 Mr. Mark Job Responsible Third Party Official Regulatory Technology Services, LLC 1394 25th Street NW Buffalo, Minnesota 55313

Re: K090369

Trade/Device Name: The ProDrive Line of Dental Handpieces Regulation Number: 21 CFR 872.4200 Regulation Name: Dental Handpiece and Accessories Regulatory Class: I Product Code: EFB Dated: February 12, 2009 Received: February 13, 2009

Dear Mr. Job:

This letter corrects our substantially equivalent letter of February 27, 2009.

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

{4}------------------------------------------------

Page 2-Mr. Job

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820): and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please contact the CDRH/Office of Surveillance and Biometrics/Division of Postmarket Surveillance at 240-276-3464. For more information regarding the reporting of adverse events, please go to http://www.fda.gov/cdrh/mdr/.

You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.

Sincerely yours.

Susan Suara

Susan Runner, D.D.S., MA Acting Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health

{5}------------------------------------------------

Indications for Use

510(k) Number (if known): Not yet assigned

Device Name:

The ProDrive Line of Dental Handpieces

Indications For Use:

To be used in the dental operatory to prepare dental cavities for restorations such as fillings, and for cleaning teeth.

Prescription Use x (Part 21 CFR 801 Subpart D) AND/OR

Over-The-Counter Use (21 CFR 801 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Supa Russer

(Division Sign-Off) Division of Anesthesiology, General Hospital Infection Control, Dental Devices

Page 1 of 1

19026 510(k) Number:

§ 872.4200 Dental handpiece and accessories.

(a)
Identification. A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or belt-driven, hand-held device that may include a foot controller for regulation of speed and direction of rotation or a contra-angle attachment for difficult to reach areas intended to prepare dental cavities for restorations, such as fillings, and for cleaning teeth.(b)
Classification. Class I.