PRUITT CAROTID KIT
K103356 · LeMaitre Vascular, Inc. · MJN · Dec 8, 2010 · Cardiovascular
Device Facts
| Record ID | K103356 |
| Device Name | PRUITT CAROTID KIT |
| Applicant | LeMaitre Vascular, Inc. |
| Product Code | MJN · Cardiovascular |
| Decision Date | Dec 8, 2010 |
| Decision | SESE |
| Submission Type | Special |
| Regulation | 21 CFR 870.4450 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Intended Use
The Pruitt F3 carotid shunts are indicated for use in carotid endarterectomy as a temporary conduit to allow for blood flow between the common and internal carotid arteries. The size 8 French Shunt is intended for use on those patients whose vasculature is too small to accommodate a size 9 French Shunt. The patch is intended for use as a surgical patch material for: cardiac and vascular re-construction and repair, soft tissue deficiency repair and reinforcing the suture line during general surgical procedures.
Device Story
Pruitt Carotid Kit is a convenience kit combining Pruitt F3 carotid shunt and XenoSure (Peripatch) biologic patch. Shunt acts as temporary conduit for blood flow between common and internal carotid arteries during carotid endarterectomy. Patch serves as surgical material for vascular/cardiac reconstruction and soft tissue repair. Kit used in surgical settings by physicians. No complex processing or electronic components involved.
Clinical Evidence
No clinical data provided; bench testing only.
Technological Characteristics
Convenience kit consisting of Pruitt F3 carotid shunt and XenoSure (Peripatch) biologic patch. No changes to materials or design of individual components from predicate devices.
Indications for Use
Indicated for patients undergoing carotid endarterectomy requiring temporary blood flow conduit between common and internal carotid arteries; size 8 French shunt for patients with vasculature too small for 9 French. Patch indicated for cardiac/vascular reconstruction, repair, soft tissue deficiency repair, and suture line reinforcement in general surgery.
Regulatory Classification
Identification
A vascular clamp is a surgical instrument used to occlude a blood vessel temporarily.
Predicate Devices
- Pruitt F3 Carotid Shunt (K051067)
- Peripatch Biologic Patch (K040835)
Related Devices
- K020132 — CHASE CARDIOVASCULAR PATCH KIT · Chase Medical, Inc. · Feb 26, 2002
- K022093 — CHASE CARDIOVASCULAR PATCH KIT · Chase Medical, Inc. · Sep 20, 2002
- K021608 — SMITHWICK CAROTID SHUNT · Implantable Devices · Oct 22, 2002
- K172660 — Duravess bovine pericardial vascular patch · Edwards Lifesciences, LLC · Nov 17, 2017
- K051067 — PRUITT F3 OUTLYING AND INLYING CAROTID SHUNT (WITH AND WITHOUT T-PORT) · LeMaitre Vascular, Inc. · May 27, 2005
Submission Summary (Full Text)
{0}------------------------------------------------
K103356 page 1 of 1
# DEC - 8 2010
## SECTION 6: 510(K) Summary
| Submitter: | LeMaitre Vascular, Inc.<br>63 Second Avenue<br>Burlington, MA 01803 |
|----------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Contact Person: | Vic Zhang<br>Sr. Regulatory Affairs Specialist<br>Phone: 781-221-2266 x162<br>Fax: 781-425-5049<br>Email: xzhang@lemaitre.com |
| Date Prepared: | November 12, 2010 |
| Trade Name: | Pruitt Carotid Kit |
| Common Name: | Carotid Kit |
| Classification Name: | N/A |
| Predicate Device: | Pruitt F3 Carotid Shunt (K051067)<br>Peripatch Biologic Patch (K040835) |
| Device Description: | The Pruitt Carotid Kit is a convenience kit composed of Pruitt F3 carotid shunt and XenoSure (Peripatch) biologic patch. |
| Intended Use: | The Pruitt F3 carotid shunts are indicated for use in carotid endarterectomy as a temporary conduit to allow for blood flow between the common and internal carotid arteries. The size 8 French Shunt is intended for use on those patients whose vasculature is too small to accommodate a size 9 French Shunt.<br>The patch is intended for use as a surgical patch material for: cardiac and vascular re-construction and repair, soft tissue deficiency repair and reinforcing the suture line during general surgical procedures. |
| Summary of Technological<br>Characteristics: | The Pruitt Carotid Kit is a convenience kit composed of the Pruitt F3 carotid shunt and XenoSure (Peripatch) biologic patch. |
| Summary of Product<br>Testing: | N/A |
| Conclusion: | LeMaitre Vascular has demonstrated that the Pruitt Carotid Kit is substantially equivalent to the predicate devices based on its indications for use and fundamental scientific technology. |
{1}------------------------------------------------
Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle with three lines forming its body and wings. The words "DEPARTMENT OF HEALTH & HUMAN SERVICES. USA" are arranged in a circular pattern around the eagle.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002
LeMaitre Vascular Inc. c/o Vic Zhang Sr. Regulatory Affairs Specialist 63 2nd Ave. Burlington, MA 01803
DEC - 8 2010
Re: K103356
Trade/Device Name: Pruitt Carotid Kit Regulation Number: 21 CFR 870.4450 Regulation Name: Vascular Clamp Regulatory Class: Class II (two) Product Code: MJN, FTM Dated: November 12, 2010 Received: November 16, 2010
Dear Mr. Zhang:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{2}------------------------------------------------
Page 2 - Mr. Vic Zhang
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportalProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely yours,
buna R. v. chmis
Image /page/2/Picture/7 description: The image shows a handwritten word "Branch" above the word "Direct". To the left of the words is a curved line with an arrow pointing to the right. The image is in black and white.
Bram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{3}------------------------------------------------
K103356 page
#### SECTION 5: INDICATION FOR USE STATEMENT
510(k) Number (if known): K403356
DEC - 8 2010
Device Name: Pruitt Carotid Kit
#### Indications for Use:
For Pruitt F3 Carotid Shunts:
The Pruitt F3 carotid shunts are indicated for use in carotid endarterectomy as a temporary conduit to allow for blood flow between the common and internal carotid arteries. The size 8 French Shunt is intended for use on those patients whose vasculature is too small to accommodate a size 9 French Shunt.
For XenoSure Biologic Patch:
The patch is intended for use as a surgical patch material for: cardiac and vascular reconstruction and repair, soft tissue deficiency repair and reinforcing the suture line during general surgical procedures.
Prescription Use X
(Part 21 CFR 801 Subpart D) (21 CFR 807 Subpart C)
### (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE ID NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
b.k.hmer
(Division Sign-Off) Division of Cardiovascular Devices
K103356 510(k) Number_