    510k Summary Text (Full-text Search) :

    Re: K243270**
    Trade/Device Name: TigerConnect Alarm Management
    Regulation Number: 21 CFR 870.2300
    Communication, Physiological Monitors

    Primary Classification Regulation / Product Code, and Name
    21 CFR §870.2300

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The intended use of TigerConnect Alarm Management is to provide an interface with clinical systems to forward information associated to the particular event to the designated display device(s).

    For medical alarms, TigerConnect Alarm Management is intended to serve as a parallel, redundant, forwarding mechanism to inform healthcare professionals of particular medical related events TigerConnect Alarm Management does not alter the behavior of the primary medical devices and associated alarm annunciations. The display device provides a visual, and/or audible and/or vibrating mechanism upon receipt of the alert.

    TigerConnect Alarm Management is intended for use as a secondary alert. It does not replace the alarm function on the primary device.

    Device Description

    TigerConnect (TC) Alarm Management is a software as a medical device (SaMD) installed on the Amazon Web Services (AWS) TigerConnect cloud capable of acquiring alarms, events, and parameters from healthcare systems, and intelligently forwarding this information as secondary notifications to designated commercial endpoint devices. The endpoint devices act as non-regulated medical device data system (MDDS) devices that display the information from TC Alarm Management.

    TC Alarm Management is intended for use as a secondary alarm; it does not replace the alarm function on the primary device.

    Users receive interactive, time-critical information from clinical systems directly via their endpoint devices as text (visual) or alarms (audible) or data. Received attributes related to the presentation of alerts include color and quantity of tones (beeps) in addition to, and in coordination with, event priorities. TC Alarm Management allows users to be aware of their patients' status and alarm conditions when they are away from the patient and patient monitoring system.

    A portion of the software, the Health Services Agent, is deployed to the customers' premises using ECS Anywhere, an extension of Amazon ECS that allows customers to run native ECS tasks on customer-managed infrastructure without compromising on the simplicity and control of the cloud. ECS Anywhere must be deployed in a customer provided virtual machine prior to implementing the Health Systems Agent. This allows TC Alarm Management to securely send, receive, process, and appropriately encrypt data from systems that are typically unencrypted.

    TC Alarm Management connects to the information sources through wired ethernet connections which are part of the customer's infrastructure and acquires patient data from primary medical device sources and clinical systems. TigerConnect implementation engineers configure TC Alarm Management, in collaboration with the customer, to determine which information, including alarm notifications, is delivered to which users. TC Alarm Management then formats the data for wireless delivery to the endpoint devices through TigerConnect's proprietary Clinical Collaboration Platform (CCP) non-regulated MDDS messaging service.

    TC Alarm Management is designed to accept inputs from a variety of healthcare systems utilizing the HL7 Minimum Lower Layer Protocol (MLLP) communication protocol. These clinical systems include the following:

    • Medical device gateways providing HL7 MLLP communications, which includes, but is not limited to, the following parameters and events surrounding them, e.g. alarms:
      • Patient monitors such as electrocardiograms (ECGs), respiratory rate, pulse oximetry (SpO2 and heart rate), end-tidal carbon dioxide (EtCO2), non-invasive blood pressure, cardiac output, temperature and associated derived outputs.
      • Lung ventilators.
      • Respiratory gas monitors.
      • IV infusion (including patient-controlled analgesia) pumps.
    • Nurse call systems.
    • Electronic health record (EHRs) systems.

    TC Alarm Management provides a wireless communications system platform for delivery of secondary notifications to endpoint devices with Android or iOS operating systems (OSs) through the CCP messaging service.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K241882

    Validate with FDA (Live)

    Date Cleared
    2025-08-27

    (425 days)

    Product Code
    Regulation Number
    884.2740
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    and accessories, HGM

    • 21 CFR 884.2960 Obstetric ultrasonic transducer and accessories, HGL
    • 21 CFR 870.2300
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Fetal & Maternal Monitor (Model: F15A, F15A Air) is intended for providing Non-Stress testing or fetal monitoring for pregnant women from the 28th week of gestation. It is intended to be used only by trained and qualified personnel in antepartum examination rooms, labor and delivery rooms.

    Fetal & Maternal Monitor (Model: F15A, F15A Air) is intended for real time monitoring of fetal and maternal physiological parameters, including non-invasive monitoring and invasive monitoring:

    Non-invasive physiological parameters:

    • Maternal heart rates (MHR)
    • Maternal ECG (MECG)
    • Maternal temperature (TEMP)
    • Maternal oxygen saturation (SpO2) and pulse rates (PR)
    • Fetal heart rates (FHR)
    • Fetal movements (FM)
    • FTS-3

    Note: SpO2 and PR are not available in F15A Air.

    Invasive physiological parameters:

    • Uterine activity
    • Direct ECG (DECG)
    Device Description

    The F15A series fetal and maternal monitor can monitor multiple physiological parameters of the fetus/mother in real time. F15A series can display, store, and print patient information and parameters, provide alarms of fetal and maternal parameters, and transmit patient data and parameters to Central Monitoring System.

    F15A series fetal and maternal monitors mainly provide following primary feature:

    Non-invasive physiological parameters:

    • Maternal heart rates (MHR)
    • Maternal ECG (MECG)
    • Maternal temperature (TEMP)
    • Maternal oxygen saturation (SpO2) and pulse rates (PR)
    • Fetal heart rates (FHR)
    • Fetal movements (FM)
    • FTS-3

    Note: SpO2 and PR are not available in F15A Air.

    Invasive physiological parameters:

    • Uterine activity
    • Direct ECG (DECG)
    AI/ML Overview

    The provided FDA 510(k) clearance letter and summary for the Fetal & Maternal Monitor (F15A, F15A Air) do not contain the detailed information necessary to fully answer all aspects of your request regarding acceptance criteria and the study that proves the device meets them.

    The document focuses primarily on demonstrating substantial equivalence to a predicate device (Edan Instruments, Inc., F9 Express Fetal & Maternal Monitor, K173042) through comparison of intended use, technological characteristics, and conformance to various safety and performance standards. It mentions "functional and system level testing to validate the performance of the devices" and "results of the bench testing show that the subject device meets relevant consensus standards," but it does not specify quantitative acceptance criteria for each individual physiological parameter (e.g., FHR accuracy, SpO2 accuracy) nor the specific results of those tests beyond stating that they comply with standards.

    Specifically, the document does not include information on:

    • A table of acceptance criteria with specific quantitative targets for each parameter and the reported device performance values against those targets. It only states compliance with standards.
    • Sample sizes used for a "test set" in the context of clinical performance evaluation (it mentions "bench testing," but this is typically laboratory-based and doesn't involve patient data in a "test set" sense for AI/algorithm performance validation).
    • Data provenance for such a test set (e.g., country of origin, retrospective/prospective).
    • Number or qualifications of experts used to establish ground truth.
    • Adjudication methods.
    • Multi-Reader Multi-Case (MRMC) studies or human reader improvement data with AI assistance.
    • Standalone (algorithm-only) performance, as this is a monitoring device, not a diagnostic AI algorithm.
    • Type of ground truth (beyond "bench testing" which implies engineered signals or controlled environments).
    • Sample size for a training set or how ground truth for a training set was established. This device is a traditional medical device, not an AI/ML-driven diagnostic or interpretative algorithm in the way your request implies.

    Therefore, based solely on the provided text, I can only address what is present or infer what is missing.

    Here's a breakdown based on the available information:


    Analysis of Acceptance Criteria and Performance Testing based on Provided Document

    The provided 510(k) summary focuses on demonstrating substantial equivalence to a predicate device (F9 Express Fetal & Maternal Monitor, K173042) by showing that the new device (F15A, F15A Air) has the same intended use and fundamentally similar technological characteristics, with any differences not raising new safety or effectiveness concerns.

    1. A table of acceptance criteria and the reported device performance

    The document does not provide a specific table with quantitative acceptance criteria for each physiological parameter (e.g., FHR accuracy, SpO2 accuracy) and the corresponding reported performance values obtained in testing. Instead, it states that the device was assessed for conformity with relevant consensus standards. For example, it lists:

    • IEC 60601-2-37:2015: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment (relevant for FHR).
    • ISO 80601-2-61:2017+A1:2018: Particular requirements for basic safety and essential performance of pulse oximeter equipment (relevant for SpO2).
    • ISO 80601-2-56:2017+A1:2018: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement (relevant for TEMP).
    • IEC 60601-2-27:2011: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment (relevant for MECG/DECG).

    Acceptance Criteria (Inferred from standards compliance): The acceptance criteria are implicitly the performance requirements specified within these listed consensus standards. These standards set limits for accuracy, precision, response time, and other performance metrics for each type of measurement.

    Reported Device Performance: The document states: "The results of the bench testing show that the subject device meets relevant consensus standards." This implies that the measured performance statistics (e.g., accuracy, bias, precision) for each parameter fell within the acceptable limits defined by the respective standards. However, the specific measured values are not provided in this summary.

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document mentions "Bench Testing" which implies laboratory-based testing using simulators, controlled signals, or phantoms, rather than a "test set" involving patient data. There is no information provided regarding:

    • Sample size (e.g., number of recordings, duration of recordings, number of simulated cases) for the bench tests for each parameter.
    • Data provenance (e.g., country of origin, retrospective or prospective) as this is not a study involving patient data collection for performance validation.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This is not applicable and not provided. For a traditional physiological monitor, ground truth for bench testing is typically established using:

    • Calibrated reference equipment/simulators: e.g., ECG simulators to generate known heart rates, SpO2 simulators to generate known oxygen saturation levels.
    • Physical standards/phantoms: e.g., temperature baths at known temperatures.
    • Known physical properties: e.g., precise weights for pressure transducers.

    Clinical experts are not involved in establishing ground truth for bench performance of these types of physiological measurements.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This is not applicable and not provided. Adjudication methods are relevant for human expert review of complex clinical data (e.g., medical images for AI validation) to establish a consensus ground truth. For bench testing of physiological monitors, ground truth is objectively determined by calibrated instruments or defined physical parameters.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This is not applicable and not provided. An MRMC study is typically performed to evaluate the diagnostic accuracy of AI-assisted human interpretations versus unassisted human interpretations for AI-driven diagnostic devices. The Fetal & Maternal Monitor is a physiological monitoring device, not an AI-assisted diagnostic imaging or interpretation system. It measures and displays physiological parameters; it does not provide AI-driven assistance for human "readers" to interpret complex clinical information.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    The device is a monitor that directly measures physiological parameters. It is not an "algorithm only" device in the sense of an AI model providing a diagnostic output. Its performance (e.g., FHR accuracy) is its standalone performance, as it directly measures these parameters. The document states "functional and system level testing to validate the performance of the devices," which would represent this type of standalone performance for the measurement functionalities. However, specific quantitative results are not given, only compliance with standards.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    As explained in point 3, the ground truth for bench testing of physiological monitors is established using calibrated reference equipment/simulators and physical standards.

    8. The sample size for the training set

    This is not applicable and not provided. This device is a traditional physiological monitor, not a machine learning model that requires a "training set." Its algorithms for parameter measurement are based on established physiological principles and signal processing techniques, not on statistical learning from large datasets.

    9. How the ground truth for the training set was established

    This is not applicable and not provided for the same reasons as point 8.

    Ask a Question

    Ask a specific question about this device

    K Number
    K241766

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-08-27

    (433 days)

    Product Code
    Regulation Number
    870.2300
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Trade/Device Name: QMAPP® (Hemo, Hemo Lite, PCM, GO, Hybrid)
    Regulation Number: 21 CFR 870.2300
    Physiological, Patient (Without Arrhythmia Detection Or Alarms) |
    | Classification #: | 21 CFR 870.2300

    • | Same as primary predicate device | 21 CFR 870.1425, DQK Programmable diagnostic computer 21 CFR 870.2300
      including cardiotachometer and rate alarm) | 21 CFR 870.1425, DQK Programmable diagnostic computer 21 CFR 870.2300
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    QMAPP® is intended for use by professional healthcare providers for physiological/hemodynamic monitoring. The system may be used to display and analyze surface ECG (Electrocardiogram), respiration, invasive pressures, pulse oximetry (SpO2), End tidal CO2 (EtCO2), fractional flow reserve (FFR), non-invasive blood pressure (NiBP), surface body temperature, cardiac output and intra-cardiac ECG. QMAPP® provides also clinical data acquisition, medical image/data processing and analytical assessment. QMAPP® is intended for use in the areas of, but not limited to cardiology, cardiac catheterization, electrophysiology, radiology, invasive radiology. QMAPP® can be used standalone and in networked environments. The system is intended for patient/procedural data management, such as documentation, logging, reporting, trending, storing, reviewing, carrying out clinical calculations and exporting various representations of the acquired data. Data may also be acquired from and/or send to other devices, such as physiological monitoring system, information management systems, image acquisition/storage devices and other medical devices.

    Device Description

    The QMAPP® system offers a complete physiological/hemodynamic monitoring and reporting system. The system is built from three units: an Amplifier, Live Monitoring CPU and Reporting CPU. The Amplifier Unit has various sensors connected with the patient, e.g. ECG, SpO2 and NiBP. The Amplifier Unit is connected to the Live Monitoring CPU via a dedicated Ethernet connection. The acquired patient information can be visualized on a Live Monitoring CPU. Typically located in the technical room. A software application executed on the Live Monitoring CPU can visualize the patient information. Also the Amplifier Unit can be controlled, i.e. most importantly, to set acquisition and filtering parameters for the different sensors, by the Live Monitoring CPU. Optionally the Monitoring unit can be connected via a dedicated Ethernet connection to a Reporting CPU, typically located in the technical room. On the Reporting CPU a database is installed which facilitates data storage and retrieval. A software application executed on the Reporting CPU serves as a patient data management system. It can e.g. be used for analysis, calculation and reporting in various representations of patient information.
    The QMAPP® system, can operate standalone or it can be part of a typical hospital network infrastructure. The latter offers the possibility to send or receive information from and to other devices. The software has several communication modules, based on HL7 or DICOM protocols to interface with third party equipment/systems.
    • The QMAPP® system works with 3rd party 510(k) cleared SpO2 module (Covidien Nellcor, K083325), NiBP module (CAS Medical Systems, MAXNIBP ND+, e.g. used in FDA cleared device CAS Medical Systems, 740 Select, K150620) and EtCO2 sensors e.g. used in FDA cleared device CLEO Patient Monitor, K142244.

    AI/ML Overview

    The provided FDA 510(k) Clearance Letter for the QMAPP® System describes the device, its intended use, and a summary of non-clinical tests conducted to support its substantial equivalence. However, the document does not contain the specific details required to fully address your request regarding acceptance criteria and the comprehensive study that proves the device meets them.

    Here's a breakdown of what can and cannot be extracted from the provided text, and where the requested information is missing:

    Information Present in the Document:

    • Overall Device Performance: The "NON-CLINICAL TESTS" section lists various characteristics on which "Bench testing" was carried out, implicitly suggesting these are areas where performance was evaluated. The "Referenced Standards and Performance Testing" section explicitly states that the QMAPP® system "meets the requirements of following performance Standards."
    • Study Type: The studies mentioned are "Bench testing," "Usability Testing," and "Software verification and validation testing." The clearance is based on a "Traditional 510(k)" and relies on "non-clinical data."
    • Ground Truth Type (for non-clinical testing): For the performance characteristics listed (ECG, Heart rate, SpO2, NiBP, IBP, Cardiac Output, Intra cardiac ECG, Skin Temperature, ECG impedance for Rate of respiratory effort, Measurement accuracy), the "ground truth" would be established by the physical standards and reference systems used during bench testing for each specific measurement. For example, a calibrated heart rate simulator would provide the ground truth for heart rate accuracy.
    • Sample Size for Training Set: Not explicitly mentioned, but the document refers to a "software verification and validation testing," implying a dataset (likely synthetic or previously collected) was used.
    • How Ground Truth for Training Set was Established: Not explicitly mentioned.

    Missing Information (Crucial for your request):

    The document focuses on demonstrating substantial equivalence to predicate devices through technical characteristics and adherence to recognized standards. It does not present a detailed study report with specific acceptance criteria, reported performance against those criteria, or the methodology of how "ground truth" was established for clinical or test datasets in the manner you've requested for an AI/ML context.

    The QMAPP® system is a physiological/hemodynamic monitoring system, not specifically an AI/ML device that requires a comparison of algorithmic output against expert consensus on a test set, multi-reader multi-case studies, or standalone algorithm performance. The "clinical data acquisition, medical image/data processing and analytical assessment" mentioned are functions of the system, but the document does not elaborate on an AI/ML component with associated performance metrics.


    Based on the provided text, here is what can be inferred and explicitly stated, with clear indications of missing information for your request:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document states that the QMAPP® system was tested against and "meets the requirements of following performance Standards." These standards themselves contain detailed acceptance criteria for various parameters. The table below excerpts the performance characteristics mentioned in the "SUBSTANTIAL EQUIVALENCE SUMMARY TABLE" and "NON-CLINICAL TESTS" sections. Crucially, the document does not provide the specific numerical acceptance criteria (e.g., minimum accuracy percentages, maximum deviations) or the actual measured performance values against those criteria in a consolidated table. Instead, it states that the device "meets the requirements" of the listed standards and has "Accuracy" values which are the specifications for the device itself, not acceptance criteria of a study.

    Acceptance Criteria (via referenced standards & device specs)Reported Device Performance (as stated in 510(k) summary)
    Electrocardiograph (ECG)Tested via Bench Testing; Meets IEC 60601-2-27:2016
    ECG Resolution24 bit
    ECG Input impedance> 2.5 MOhm
    ECG Common mode rejection> 100 dB
    ECG Sampling frequency2 – 32 KHz
    ECG Channels12
    Heart RateTested via Bench Testing; Meets performance standards
    HR MethodQRS detection
    HR Range15 – 300 bpm
    HR Accuracy± 2%
    Respiration EffortTested via Bench Testing; Meets performance standards
    Respiration MethodImpedance Pneumography
    Respiration Resolution1/min
    Respiration Range0 – 150 / Min
    Respiration Channels1
    Non-Invasive Blood Pressure (NiBP)Tested via Bench Testing; Meets IEC 80601-2-30:2018
    NiBP MethodOscillometric (CAS Max module)
    NiBP Range15 - 260 mm Hg
    NiBP Accuracy± 5 mm Hg
    Oxygen Saturation (SpO2)Tested via Bench Testing; Meets ISO 80601-2-61:2017
    SpO2 MethodNellcor Oximax
    SpO2 Range1 - 100%
    SpO2 Accuracy± 1%
    SpO2 Channels1
    Invasive Blood Pressure (IBP)Tested via Bench Testing; Meets IEC 60601-2-34:2011
    IBP MethodPressure transducer
    IBP Accuracy± 2 mm Hg or ± 1 %
    IBP Range-30 - 320 mm Hg
    IBP Channels4
    Skin TemperatureTested via Bench Testing; Meets ISO 80601-2-56:2017
    Skin Temp MethodThermistor, YSI compatible
    Skin Temp Range20° – 45° C (68° – 113° F)
    Skin Temp Accuracy± 0.1° C (± 0.18° F)
    Skin Temp Channels2
    Cardiac OutputTested via Bench Testing; Meets performance standards
    CO MethodThermo Dilution and (calculated) FICK
    CO Range0.1 – 20 L
    CO Accuracy± 0.1 L
    End Tidal CO2 (EtCO2)Tested via Bench Testing; Meets performance standards
    EtCO2 MethodLow flow Side stream
    EtCO2 Resolution0.1 mm Hg (0-49), 0.2 mm Hg (49-152)
    EtCO2 Accuracy0-40 mmHg, ± 2 mmHg; 41-70 mmHg, ± 5%; 71-100 mmHg, ± 8%; >101 10%
    Intra cardiac ECGTested via Bench Testing; Meets performance standards
    Intra Cardiac ECG MethodElectro Physiology catheter
    Intra Cardiac ECG Resolution24 Bit
    Intra Cardiac ECG Input impedance> 2.5 MOhm
    Intra Cardiac ECG Common mode rejection> 100 dB
    Intra Cardiac HR range15 – 300 bpm
    Intra Cardiac Sampling frequency2 - 32 kHz
    Intra Cardiac Channels8, 16 or 32 (bipolar) Channels
    Other General Performance
    Electromagnetic compatibility (EMC)Meets IEC 60601-1-2:2014
    Electrical safety testingMeets AAMI/ANSI EC 60601-1:2005/(R)2012 & A1:2012 C1:2009/(R)2012 & A2:2010/(R)2012
    Mechanical safety testingMeets AAMI/ANSI EC 60601-1:2005/(R)2012 & A1:2012 C1:2009/(R)2012 & A2:2010/(R)2012
    Software verification and validation testingConducted
    Usability TestingConducted

    2. Sample size used for the test set and the data provenance

    • Sample Size for Test Set: Not specified. The document only mentions "Bench testing," "Usability Testing," and "Software verification and validation testing." These are typically performed in a lab environment.
    • Data Provenance (e.g., country of origin of the data, retrospective or prospective): Not specified. Given it's bench testing, actual patient data provenance is not directly relevant for the stated tests, but the data used for software verification and validation testing (if involving patient data) is not detailed.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • Number of Experts & Qualifications: Not applicable/not specified. For bench testing of physiological monitoring devices, the "ground truth" comes from calibrated testing equipment and reference signals, not expert human interpretation in the way, for example, a radiology AI would be evaluated. The "Software verification and validation testing" is also not described as relying on expert review of a patient dataset for ground truth.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Adjudication Method: Not applicable/not specified. This methodology is typically used when comparing an algorithm's output to human expert interpretations, which is not the type of testing described for this physiological monitor.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • MRMC Study: Not applicable. The QMAPP® system is described as a physiological/hemodynamic monitoring, data acquisition, and analytical assessment system. It is not presented as an AI-assisted diagnostic tool designed to improve human reader performance in interpreting images or complex clinical scenarios.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    • Standalone Performance: The described "Bench testing" and "Software verification and validation testing" can be considered "standalone" in the sense that they evaluate the device's inherent measurement and processing capabilities without a human in the loop for interpretation, but for a physiological monitor, the ultimate "human-in-the-loop" is the clinician using the displayed information. The document does not describe an AI algorithm that operates entirely independently to make a diagnosis or prediction in the same way an AI for image analysis might.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • Type of Ground Truth: For the "Bench testing" of physiological parameters, the ground truth would be established by calibrated reference standards and simulated physiological signals. For instance, a signal generator provides a known ECG waveform or blood pressure reading, and the device's measurement is compared to this known input.

    8. The sample size for the training set

    • Sample Size for Training Set: Not specified. The document mentions "Software verification and validation testing," which would involve a dataset, but its size is not detailed. There is no mention of a "training set" in the context of an AI/ML model, as the device is not presented as such.

    9. How the ground truth for the training set was established

    • How Ground Truth for Training Set was Established: Not specified. If a "training set" was used for software validation (e.g., for signal processing algorithms), the ground truth would likely be established through
      • Synthetic data: Ground truth is known by design.
      • Previously validated physiological data: Data collected with highly accurate reference devices, where the "truth" for various physiological parameters is established by the reference device's measurements.

    In summary: The FDA 510(k) clearance document for the QMAPP® System confirms that the device meets relevant performance standards through non-clinical bench testing and software validation. However, it does not provide the detailed acceptance criteria and study particulars, particularly those related to expert-adjudicated test sets, MRMC studies, or specific AI/ML training/testing methodologies, because the device is presented as a traditional physiological monitor, not an AI-powered diagnostic system.

    Ask a Question

    Ask a specific question about this device

    K Number
    K251494

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-08-12

    (89 days)

    Product Code
    Regulation Number
    870.1875
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Regulation Number and Name | 21 CFR 870.1875 Stethoscope | 21 CFR 870.1875 Stethoscope | 21 CFR 870.2300

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Eko Foundation Analysis Software with Transformers (EFAST) is intended to support healthcare professionals in the evaluation of patients' heart sounds and electrocardiograms (ECGs). The software calculates heart rate, detects the presence of murmurs associated with Structural Heart Disease, and determines murmur timing including the timing of S1, S2 heart sounds. When ECG is available, the software detects the presence of atrial fibrillation and normal sinus rhythm.

    The software is intended for use by or under the supervision of a healthcare professional and is not to be used as a sole means of diagnosis. The interpretations of heart sounds and ECG offered by the software are designed to support and not replace the healthcare professional's clinical judgment. The murmur detection is intended for use on both pediatric and adult patients, while the detection of atrial fibrillation is intended for use on adults (> 18 years).

    Device Description

    Eko Foundation Analysis Software with Transformers (EFAST) is a cloud-based Software as a Medical Device (SaMD) intended to provide clinical decision support to healthcare professionals (HCP) in the evaluation of patients' heart sounds (phonocardiogram, PCG) and electrocardiograms (ECGs). The software employs signal processing techniques and machine learning (Deep Neural Networks) to perform simultaneous analysis of recorded heart sounds and ECG data (when available), and identify the presence of murmurs associated with Structural Heart Disease, and determine murmur timing including the timing of S1, S2 heart sounds. When ECG is available, the software also detects the presence of atrial fibrillation and sinus rhythm.
    The software does not identify other arrhythmias. In addition, it calculates the heart rate of the patient.

    The EFAST Software accepts input consisting of heart sounds and ECG waveforms recorded using Eko Digital Stethoscopes that are saved in .WAV file format and stored in the Eko Cloud, which utilizes the Amazon Web Services (AWS) Simple Storage Service (S3) for data storage and for easy communication with the EFAST analysis server. When an API Request is sent to the EFAST API, the corresponding recordings (PCG and/or ECG) are accessed by the EFAST software and they are analyzed by the EFAST software components. After analysis, the EFAST software returns a JSON format data structure with the algorithm results, which is saved back to the Eko Cloud and can be displayed on EFAST API integrated target software or devices (e.g. user-facing apps).

    The EFAST Software consists of the following algorithm components:

    • Heart Sound Signal Quality Classifier: Evaluates whether an audio recording contains heart sounds of sufficient quality for further clinical analysis
    • Structural Murmur Classifier: Determines whether a good-quality heart sound recording contains a structural murmur or not
    • Heart Sound Timing & Murmur Timing: Determines the timing of S1 and S2 heart sounds and determines whether a structural murmur occurs during the systolic or diastolic phase
    • ECG Rhythm Classifier: Analyzes ECG signals and categorizes them into one of four classifications: Sinus Rhythm, Atrial Fibrillation, Unspecified Rhythm, and Poor ECG Signal
    • Heart Rate Calculation: Signal processing algorithm that utilizes ECG and PCG to calculate heart rate value in beats per minute
    AI/ML Overview

    Here's a detailed breakdown of the acceptance criteria and the studies proving the device's performance, based on the provided FDA 510(k) clearance letter:

    Acceptance Criteria and Reported Device Performance

    MetricAcceptance Criteria (Implied)EFAST Reported PerformanceRelated Study
    Structural Murmur ClassificationHigh Sensitivity & SpecificitySensitivity: 83.4% (95% CI: 80.2 - 86.6)Retrospective study on 2,460 heart sound recordings
    Specificity: 86.0% (95% CI: 82.2 - 89.8)
    Structural Murmur Classification (Pediatric <18)High Sensitivity & SpecificitySensitivity: 85.9% (95% CI: 81.3 - 90.5)Retrospective study on 2,460 heart sound recordings
    Specificity: 76.0% (95% CI: 68.7 - 83.4)
    Structural Murmur Classification (Adults 18+)High Sensitivity & SpecificitySensitivity: 81.7% (95% CI: 77.5 - 86.0)Retrospective study on 2,460 heart sound recordings
    Specificity: 93.9% (95% CI: 90.6 - 97.1)
    Structural Murmur Classification (Adults 60+)High Sensitivity & SpecificitySensitivity: 82.2% (95% CI: 77.7 - 86.8)Retrospective study on 2,460 heart sound recordings
    Specificity: 90.9% (95% CI: 86.1 - 95.7)
    S1 Detection (Heart Sound Timing)High Sensitivity & PPVSensitivity: 98.58% (95% CI: 97.21-99.38)Retrospective study on 96 heart sound recordings
    PPV: 93.27% (95% CI: 90.94-95.15)
    S2 Detection (Heart Sound Timing)High Sensitivity & PPVSensitivity: 94.81% (95% CI: 92.59-96.53)Retrospective study on 96 heart sound recordings
    PPV: 94.29% (95% CI: 91.99-96.09)
    Atrial Fibrillation DetectionHigh Overall Sensitivity & SpecificityOverall Sensitivity: 94.7% (95% CI: 91.5 - 97.8)Retrospective study on 1,256 ECG recordings
    Overall Specificity: 94.1% (95% CI: 92.1 - 96.1)
    Heart Rate CalculationLow Mean Absolute Percentage ErrorMean absolute percentage error < 5%(No specific study details provided, but implies internal validation)

    Note on Acceptance Criteria: The document does not explicitly state numerical "acceptance criteria" but rather presents the device's performance results in comparison to a predicate device, implying that the demonstrated performance is considered acceptable for substantial equivalence. The predicate device's performance often sets an implicit benchmark.


    Study Details: Structural Murmur Classification

    2. Sample size used for the test set and the data provenance:

    • Test set sample size: 2,460 unique heart sound recordings (from 615 unique subjects). 259 recordings were excluded due to lack of cardiologist agreement.
    • Data provenance: Retrospective study of de-identified data. Three sites within the US (2 sites) and Canada (1 site).

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Number of experts: "Multiple cardiologists" annotated the recordings.
    • Qualifications: "Cardiologists." No further specific qualifications (e.g., years of experience) are provided in this document.

    4. Adjudication method for the test set:

    • For 2,460 initial recordings, "multiple cardiologists" annotated them.
    • For 259 of these recordings, the cardiologists "could not come to agreement," leading to their exclusion from the analysis. This implies some form of consensus or agreement-based adjudication, where a lack of agreement led to exclusion rather than a specific tie-breaking rule (e.g., 2+1, 3+1).

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No MRMC comparative effectiveness study involving human readers with vs. without AI assistance is described in this section for structural murmur classification. The comparison is between the EFAST algorithm's standalone performance and the predicate device's standalone performance ("Algorithm Performance Comparison to Predicate").

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • Yes, the presented performance metrics (Sensitivity, Specificity) are for the EFAST algorithm operating in a standalone capacity ("EFAST Structural Murmur Classification Performance" and "Algorithm Performance Comparison to Predicate").

    7. The type of ground truth used:

    • Ground truth was established by "pairing the cardiologist annotations with gold standard echocardiogram." This indicates a hybrid ground truth, combining expert interpretation with objective clinical imaging (echocardiogram).

    8. The sample size for the training set:

    • Not specified in this document. The document only mentions validation on "proprietary datasets."

    9. How the ground truth for the training set was established:

    • Not specified in this document.

    Study Details: Heart Sound Timing (S1/S2 Detection)

    2. Sample size used for the test set and the data provenance:

    • Test set sample size: 96 heart sound recordings.
    • Data provenance: Retrospective study. Data collected using Eko CORE or Eko CORE 500 Digital Stethoscopes. Country of origin not explicitly stated for this subset, but the broader structural murmur study involved US and Canada.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Number of experts: "Expert cardiologists."
    • Qualifications: "Cardiologists." No further specific qualifications are provided.

    4. Adjudication method for the test set:

    • Not explicitly stated, but "annotated by expert cardiologists" implies expert consensus for these 96 recordings, as no exclusions due to disagreement are mentioned. "Cardiologists were blinded to all subject demographic data and echocardiogram findings during annotation."

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No MRMC comparative effectiveness study described.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • Yes, the presented performance is for the EFAST algorithm in a standalone capacity ("EFAST Heart Sound Timing Performance").

    7. The type of ground truth used:

    • Expert cardiologist annotations of "timing of the S1 and S2 sounds."

    8. The sample size for the training set:

    • Not specified.

    9. How the ground truth for the training set was established:

    • Not specified.

    Study Details: ECG Rhythm Classification (Atrial Fibrillation Detection)

    2. Sample size used for the test set and the data provenance:

    • Test set sample size: 1,256 ECG recordings (from 314 unique subjects). 97 recordings were excluded due to lack of expert agreement.
    • Data provenance: Retrospective study of de-identified data. Two sites within the US.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Number of experts: "Multiple experts."
    • Qualifications: "Electrophysiologists, certified cardiographic technicians." No further specific qualifications (e.g., years of experience) are provided.

    4. Adjudication method for the test set:

    • "Multiple experts" annotated the recordings.
    • For 97 recordings, "the experts did not come to an agreement," leading to their exclusion. Similar to the structural murmur study, this indicates an agreement-based adjudication where disagreement led to exclusion.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No MRMC comparative effectiveness study involving human readers with vs. without AI assistance is described. The comparison is between the EFAST algorithm's standalone performance and the predicate device's standalone performance ("Algorithm Performance Comparison to Predicate").

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • Yes, the presented performance metrics (Overall Sensitivity, Overall Specificity) are for the EFAST algorithm operating in a standalone capacity ("EFAST Atrial Fibrillation Detection Performance" and "Algorithm Performance Comparison to Predicate").

    7. The type of ground truth used:

    • Expert annotations related to "quality and the presence of atrial fibrillation."

    8. The sample size for the training set:

    • Not specified.

    9. How the ground truth for the training set was established:

    • Not specified.

    Study Details: Heart Rate Calculation

    2. Sample size used for the test set and the data provenance:

    • Not explicitly stated, but the performance is presented as a summary ("found to be less than 5%").

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Ground truth method not explicitly detailed in the summary, but typically for heart rate, it involves reference devices or manual counting from a known good signal.

    4. Adjudication method for the test set:

    • Not explicitly stated.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No MRMC comparative effectiveness study described.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • Yes, the performance is for the algorithm itself.

    7. The type of ground truth used:

    • Implied to be a reference standard for heart rate measurement.

    8. The sample size for the training set:

    • Not specified.

    9. How the ground truth for the training set was established:

    • Not specified.
    Ask a Question

    Ask a specific question about this device

    K Number
    K242728

    Validate with FDA (Live)

    Date Cleared
    2025-07-31

    (324 days)

    Product Code
    Regulation Number
    870.2300
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    K242728**
    Trade/Device Name: BeneVision Central Monitoring System
    Regulation Number: 21 CFR 870.2300
    Name:** System, network and communication, physiological monitors

    Classification Name: 21 CFR 870.2300
    Name |
    |------------------------|--------------|----------------------|-------------------|
    | 21 CFR 870.2300

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The indications for use of the BeneVision Central Monitoring System include:

    • Real time viewing of patient clinical data and alarms from compatible physiological monitors. Viewing of non-real time patient clinical data of compatible anesthesia devices (i.e. not indicated for real-time monitoring of clinical data of compatible anesthesia devices).

    • Storage and Historical review of patient clinical data and alarms from compatible physiological monitor, and anesthesia devices.

    • Printing patient data from compatible physiological monitor, and anesthesia devices.

    • Configuration of local settings as well as synchronizing settings across the network to remote compatible physiological monitors.

    • Transfer of patient clinical data and settings between several CentralStations.

    • Provides a Resting 12 Lead interpretation of previously stored data.

    The BeneVision Central Monitoring System is a networked patient monitoring system intended for use in a fixed location, installed in professional healthcare facilities to provide clinicians remote patient monitoring. The network connections between the various devices can be any combination of Ethernet (Wired), Wireless WIFI (WLAN), and Wireless WMTS.

    The BeneVision Central Monitoring System supports one or more Mindray compatible physiological monitors, anesthesia systems and will display, store, print, and transfer information received from the compatible monitors, anesthesia systems.

    The telemetry monitoring systems are designed to acquire and monitor physiological data for ambulating patients within a defined coverage area. The BeneVision Central Monitoring System supports Telemetry Systems: TMS-6016, Telepack-608, TMS60, TM80, and TM70.

    • The TMS-6016 transmitter is intended for use on Adult and Pediatric patients to monitor ECG and SpO2 physiological data.

    • The Panorama Telepack-608 transmitter is intended for use on Adult patients to monitor ECG and SpO2 physiological data.

    • The TMS60 transmitter is intended for use on Adult and Pediatric patients over three years old to monitor ECG, SpO2, NIBP and Resp physiological data. The physiological data can be reviewed locally on the display of the transmitter. The CentralStation will support ECG, Heart Rate, SpO2, NIBP, Resp, Pulse Rate, Arrhythmia analysis, QT monitoring, and ST Segment Analysis for the TMS60.

    • The TM80/TM70 telemetry monitor is intended for use on Adult and Pediatric patients over three years old to monitor ECG, SpO2, NIBP and Resp physiological data. The physiological data can be analyzed, alarmed, stored, reviewed locally on the display of the monitor, and the CentralStation can config and display the physiological parameters from the TM80/TM70.

    The BeneVision Central Monitoring System is intended for use in professional healthcare facilities under the direct supervision of a licensed healthcare practitioner.

    Device Description

    The BeneVision Central Monitoring System (CMS) is a networked patient monitoring system intended for use in healthcare settings by, or under the direction of, a physician to provide clinicians remote patient monitoring. The target patient population is adult patients and pediatrics.

    When connected to a compatible anesthesia device, BeneVision CMS can display the parameters, waveforms and alarms of the anesthesia device. The device does not contain bi-directional capabilities for the compatible anesthesia devices.

    The BeneVision CMS includes the AlarmGUARD application. AlarmGUARD supports delivering notifications of physiological and technical alarms to clinical professionals' mobile devices. AlarmGUARD is not intended for real time monitoring of patients and is not intended to act as a primary source for alarms.

    AI/ML Overview

    It appears the provided FDA 510(k) clearance letter and summary for the BeneVision Central Monitoring System (K242728) does not contain specific acceptance criteria, test results (like sensitivity/specificity, accuracy metrics), or detailed study methodologies that directly address how the device's performance meets quantitative acceptance criteria for its intended functions.

    The document primarily focuses on demonstrating substantial equivalence to a predicate device (K220058) through:

    • Comparison of Indications for Use: Showing minor differences (expanded compatibility to include anesthesia systems, but not for real-time monitoring).
    • Technological Comparisons: Highlighting changes in operating systems, host configurations, and the addition of features like Multi-Patient Viewer separation and AlarmGUARD support.
    • Performance Data Section: This section lists the types of testing conducted but does not provide the results of those tests or specific acceptance criteria met by those results. It merely states that "Software verification and validation testing was conducted" and "Verification of the BeneVision Central Monitoring System was conducted to ensure that the product works as designed. Validation was conducted to check the design and performance of the product."

    Therefore, based solely on the provided text, I cannot extract the detailed information requested in your prompt regarding acceptance criteria, reported performance, sample sizes, expert qualifications, adjudication methods, MRMC studies, standalone performance, or training set details.

    The document confirms the following regarding the study:

    • Study Type: Software verification and validation testing, along with specific bench testing.
    • Clinical Data/Animal Testing: Not applicable/not required for this submission to establish substantial equivalence. This suggests the clearance relies on non-clinical data and comparison to the predicate.
    • Ground Truth: The document implies that the ground truth for software verification and validation would be the design specifications and expected behavior of the system, rather than clinical outcomes or expert consensus on a diagnostic task. For the "Waveform Display Accuracy from compatible Anesthesia Machine," the ground truth would likely be the direct output from the anesthesia machine itself.

    What is present in the document that somewhat relates to your request:

    • "Bench Testing" section (Page 19): This lists specific tests performed:
      • AlarmGUARD IEC 60601-2-27
      • AlarmGUARD IEC 60601-1-8
      • AlarmGUARD Human Factors
      • Waveform Display Accuracy from compatible Anesthesia Machine

    To fulfill your request as best as possible with the given information, I will have to state that many details are explicitly absent from this public 510(k) summary.


    Here's a structured response based on the provided document, indicating what information is present and what is absent:

    Device Acceptance Criteria and Performance Study Summary (K242728)

    Based on the provided FDA 510(k) Clearance Letter and Summary, detailed quantitative acceptance criteria and specific performance metrics (like accuracy, sensitivity, specificity) for the BeneVision Central Monitoring System are not explicitly presented. The submission primarily relies on demonstrating substantial equivalence to a predicate device (K220058) through verification and validation of software and specific bench testing.

    The document states that "Software verification and validation testing was conducted and documentation was provided as recommended by FDA's Guidance 'Content of Premarket Submissions for Device Software Functions: Guidance for Industry and Food and Drug Administration Staff'." It also mentions that "Verification of the BeneVision Central Monitoring System was conducted to ensure that the product works as designed. Validation was conducted to check the design and performance of the product."

    1. Table of Acceptance Criteria and Reported Device Performance

    Feature/FunctionAcceptance Criteria (As Implied/Stated in Document)Reported Device Performance (As Stated in Document)
    Real-time Viewing AccuracyImplicit: Accurate display of physiological data and alarms from compatible monitors, and non-real time data from anesthesia devices."Waveform Display Accuracy from compatible Anesthesia Machine" bench testing was conducted. Specific results (e.g., % accuracy, error rates) are not provided.
    AlarmGUARD FunctionalityCompliance with relevant IEC standards for alarms and human factors."AlarmGUARD IEC 60601-2-27," "AlarmGUARD IEC 60601-1-8," and "AlarmGUARD Human Factors" testing was conducted. Specific passing metrics or performance results are not detailed.
    Software FunctionalityMeets design specifications; performs as designed; adheres to V&V requirements."Software verification and validation testing was conducted" and "product works as designed" and "design and performance... checked." No specific quantitative metrics (e.g., defect rate, uptime) are provided.
    Compatibility (Anesthesia Devices)Successful display, storage, and transfer of non-real time data from Mindray A8, A9 anesthesia systems.The system "supports" these devices and the ability to "display, store, print, and transfer information" from them. Specific performance on this compatibility is not quantitatively described beyond the mention of related bench testing.
    Technological Performance Changes (e.g., Host Configurations, Max Connections)Device operates within new specifications and maintains safety and effectiveness.Subject device moved to Windows 11 for some components, increased minimum memory/CPU for CentralStation/WorkStation, increased max connections to 128. These are documented as "No change" for performance or as new specifications that were presumably met. Performance data specific to these upgrades (e.g., latency under max load) is not provided.

    2. Sample Size Used for the Test Set and Data Provenance

    • Test Set Sample Size: Not specified in the provided document for any of the listed tests (AlarmGUARD, Waveform Display Accuracy, general software V&V).
    • Data Provenance: Not specified (e.g., country of origin, retrospective/prospective). Given that no clinical data was used or required, the "data" would be synthetic, simulated, or derived from direct device connections during bench testing.

    3. Number of Experts and Qualifications for Ground Truth

    • Not applicable / Not specified. The document does not describe the use of human experts to establish ground truth for a diagnostic task or for the performance evaluation of this central monitoring system. The focus is on software function and electro-mechanical performance validation against design specifications and international standards.

    4. Adjudication Method for the Test Set

    • Not applicable / Not specified. No adjudication method is mentioned as human reader input for a test set is not described.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • No. The document explicitly states that "Clinical testing is not required to establish substantial equivalence to the predicate device" and does not mention any MRMC study. This device is a central monitoring system displaying physiological data, not an AI diagnostic tool requiring MRMC studies for improved human reader performance.

    6. Standalone Performance (Algorithm Only)

    • The "performance data" section lists "Software Verification and Validation Testing" and "Bench Testing" (including "Waveform Display Accuracy from compatible Anesthesia Machine"). These tests conceptually represent 'standalone' performance in that they evaluate the device's technical functions directly. However, no specific quantitative standalone performance metrics (e.g., classification accuracy, sensitivity, specificity for any internal algorithms) are provided in this summary beyond the statement that v&v was conducted to ensure the product "works as designed."

    7. Type of Ground Truth Used

    • The ground truth for the device's performance appears to be:
      • Design Specifications: For general software verification and validation.
      • External Reference Standards/Simulators: For tests like "Waveform Display Accuracy" (e.g., comparing the displayed waveform to the known, true signal generated by a simulator or the anesthesia machine itself).
      • International Standards: For AlarmGUARD functionality (e.g., IEC 60601-2-27, IEC 60601-1-8).

    8. The Sample Size for the Training Set

    • Not applicable / Not specified. This document describes a traditional medical device (patient monitoring system software) rather than a machine learning/AI device that typically requires a distinct "training set." Therefore, no training set size is mentioned.

    9. How the Ground Truth for the Training Set Was Established

    • Not applicable / Not specified. As no training set for an AI/ML model is indicated, there is no mention of how its ground truth would be established.
    Ask a Question

    Ask a specific question about this device

    K Number
    K250179

    Validate with FDA (Live)

    Date Cleared
    2025-07-29

    (188 days)

    Regulation Number
    870.1025
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Detector and Alarm, Arrhythmia | DSI |
    | 21 CFR 870.1025 Monitor, ST Segment with Alarm | MLD |
    | 21 CFR 870.2300

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The monitors are intended to be used for monitoring, storing, recording, and reviewing of, and to generate alarms for, multiple physiological parameters of adults and pediatrics (including neonates). The monitors are intended for use by trained healthcare professionals in hospital environments.

    The monitored physiological parameters include: ECG, respiration (RESP), temperature (TEMP), functional oxygen saturation of arterial hemoglobin (SpO₂), pulse rate (PR), non-invasive blood pressure (NIBP), invasive blood pressure (IBP), carbon dioxide (CO2), and cardiac output (C.O.).

    The arrhythmia detection and ST Segment analysis are intended for adult patients.

    The NIBP monitoring supports iCUFS algorithm and iFAST algorithm. The iCUFS algorithm is intended for adult, pediatric and neonatal patients. The iFAST algorithm is intended for adult and pediatric patients (≥3 years of age). Both measurement algorithms are also intended for use with pregnant women, including pre-eclamptic patients. NIBP MAP is not applicable to pregnant women.

    The Spot Temp with T2A module can only measure temperature of adult and pediatric (> 1 year of age) patients.

    The monitors are not intended for MRI environments.

    The cardiac output (C.O.) is only intended for adult patients.

    Device Description

    The CX&UX series Patient Monitor including CX10/CX12/CX15/UX10/UX12/UX15 can perform long-time continuous monitoring of multiple physiological parameters. Also, it is capable of storing, displaying, analyzing and controlling measurements, and it will indicate alarms in case of abnormalities so that doctors and nurses can respond to the patient's situation as appropriate.

    Minor differences from the predicate device are limited to some modifications of monitoring parameter specifications. These updates do not change the fundamental scientific technology of the cleared predicate device and thus do not raise any questions about the safety and effectiveness of the subject device.

    AI/ML Overview

    The provided FDA 510(k) clearance letter details the device's technical specifications and comparisons to predicate devices, along with the non-clinical performance data and adherence to various IEC and ISO standards. However, it explicitly states: "Clinical data: The subject device did not require new clinical studies to support substantial equivalence."

    This means that the submission for this Patient Monitor device (CX10, CX12, CX15, UX10, UX12, UX15) relies on demonstrating substantial equivalence to a legally marketed predicate device (Edan Instruments, Inc., Patient Monitor Model iX10, iX12, iX15, K232962) through non-clinical performance testing and software verification/validation, rather than new clinical trials or studies involving human patients.

    Therefore, the requested information regarding acceptance criteria and studies that prove the device meets acceptance criteria through clinical performance (e.g., sample size for test set, expert involvement, MRMC studies, ground truth establishment for test/training sets, effect size of human reader improvement with AI) cannot be extracted from this document, as such clinical studies were explicitly not required for this 510(k) submission.

    The document focuses on demonstrating that the new device's technical specifications and performance are similar to the predicate device, and that it complies with relevant safety and performance standards through bench testing.

    Here's what can be extracted from the provided text regarding acceptance criteria and the type of study performed, specifically focusing on the non-clinical aspects:


    Device: Patient Monitor (CX10, CX12, CX15, UX10, UX12, UX15)

    The acceptance criteria for this device are implicitly tied to its performance meeting the standards and accuracy specifications of the predicate device and relevant international standards. Since no new clinical studies were conducted, the "proof" comes from non-clinical bench testing and software validation.

    1. Table of Acceptance Criteria and Reported Device Performance (Non-Clinical/Bench Testing)

    Parameter/Acceptance Criteria TypeDetails of Acceptance Criteria (Implicit from Standards Compliance & Predicate Equivalence)Reported Device Performance (as demonstrated by compliance)
    Electrical SafetyCompliance with IEC 60601-1 Edition 3.2 2020-08Complies with IEC 60601-1 Edition 3.2 2020-08
    Electromagnetic Compatibility (EMC)Compliance with IEC 60601-1-2:2014 (Fourth Edition)Complies with IEC 60601-1-2:2014 (Fourth Edition)
    Alarm SystemsCompliance with IEC 60601-1-8:2020 (General requirements, tests, and guidance for alarm systems)Complies with IEC 60601-1-8:2020
    ECG Monitoring Equipment PerformanceCompliance with IEC 60601-2-27:2011 (Basic safety and essential performance of electrocardiographic monitoring equipment)Complies with IEC 60601-2-27:2011
    Invasive Blood Pressure Monitoring PerformanceCompliance with IEC 60601-2-34:2011 (Basic safety, including essential performance, of invasive blood pressure monitoring equipment)Complies with IEC 60601-2-34:2011
    Automated Non-Invasive Sphygmomanometers PerformanceCompliance with IEC 80601-2-30:2018 (Basic safety and essential performance of automated non-invasive sphygmomanometers)Complies with IEC 80601-2-30:2018
    Multifunction Patient Monitoring PerformanceCompliance with IEC 80601-2-49:2018 (Basic safety and essential performance of multifunction patient monitoring equipment)Complies with IEC 80601-2-49:2018
    Respiratory Gas Monitors PerformanceCompliance with ISO 80601-2-55:2018 (Basic safety and essential performance of respiratory gas monitors)Complies with ISO 80601-2-55:2018
    Clinical Thermometers PerformanceCompliance with ISO 80601-2-56:2017+A1:2018 (Basic safety and essential performance of clinical thermometers)Complies with ISO 80601-2-56:2017+A1:2018
    Pulse Oximeter Equipment PerformanceCompliance with ISO 80601-2-61:2017 (Basic safety and essential performance of pulse oximeter equipment)Complies with ISO 80601-2-61:2017
    Wireless CoexistenceCompliance with IEEE ANSI USEMCSC C63.27 (Evaluation of Wireless Coexistence)Complies with IEEE ANSI USEMCSC C63.27
    Software FunctionalityCompliance with FDA Guidance "Content of Premarket Submissions for Device Software Functions"Software verification and validation testing conducted and documentation provided as recommended.
    Accuracy Specifications (Example: RESP)6 rpm to 200 rpm: ±2 rpmReported as meeting this accuracy specification.
    Accuracy Specifications (Example: IBP)±2% or ±1 mmHg, whichever is greater (excluding sensor error)Reported as meeting this accuracy specification.

    2. Sample Size Used for the Test Set and Data Provenance:

    • Sample Size: Not applicable in terms of human subjects or patient data test sets, as "new clinical studies" were not required. The "test set" refers to bench testing and functional system-level validation. The specific number of test cycles or a detailed breakdown of test cases for bench testing is not provided in this summary.
    • Data Provenance: The data primarily originates from Edan Instruments Inc. (Shenzhen, Guangdong, China) through internal engineering and quality assurance processes for non-clinical bench testing and software validation. It is not patient data, so concepts like "retrospective or prospective" do not apply.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications:

    • Not applicable for clinical ground truth: Since no clinical studies were performed requiring human interpretation or diagnosis for a test set, no medical experts (e.g., radiologists) were used to establish ground truth in this context.
    • Internal experts: Bench testing and software validation would have involved engineers and quality assurance professionals, whose qualifications are implicit in the quality system (21 CFR Part 820) but not specified in detail here.

    4. Adjudication Method for the Test Set:

    • Not applicable: Adjudication methods (e.g., 2+1, 3+1) are relevant for clinical studies involving multiple readers. This was not a clinical study. Bench testing relies on established technical specifications and standard compliance.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done:

    • No: No MRMC study was performed as no new clinical studies were required or conducted. Therefore, there's no effect size of human readers improving with AI assistance. The device is a patient monitor, not an AI-assisted diagnostic tool.

    6. If a Standalone (i.e. algorithm only without human-in-the loop performance) was Done:

    • Yes (for the technical components): The "performance testing-Bench" effectively represents a standalone evaluation of the device's functional components (ECG, NIBP, SpO2, etc.) and software against defined technical specifications and standards. The "software verification and validation testing" also represents a standalone evaluation of the algorithm and software functions. The specific algorithms (e.g., iCUFS, iFAST for NIBP, arrhythmia analysis logic) are tested independently for their accuracy against known inputs or reference standards as part of bench testing.

    7. The Type of Ground Truth Used:

    • Technical/Reference Standards: For the bench testing, the "ground truth" would be derived from:
      • Reference standards/simulators: Calibrated medical equipment, physiological simulators, and test signals (e.g., known ECG waveforms, simulated blood pressure readings, temperature standards) are used to provide the "true" values against which the device's measurements are compared.
      • Defined specifications: The device's internal design specifications and the requirements of the referenced IEC/ISO standards serve as the "ground truth" for compliance testing.
    • Not clinical ground truth: No expert consensus, pathology, or outcomes data from real patients were used for establishing ground truth for this submission.

    8. The Sample Size for the Training Set:

    • Not applicable: The device is a patient monitor, not a machine learning/AI algorithm that typically undergoes a distinct "training" phase with a large dataset. Its functionality is based on established physiological measurement principles and programmed algorithms. Any internal calibration or algorithm refinement would be part of the product development process, not a dedicated "training set" in the AI/ML sense.

    9. How the Ground Truth for the Training Set Was Established:

    • Not applicable: As there was no "training set" in the context of an AI/ML model, the concept of establishing ground truth for it does not apply to this 510(k) submission.

    In summary, this 510(k) clearance relies on demonstrating that the new Patient Monitor is substantially equivalent to a previously cleared predicate device, primarily through robust non-clinical bench testing and software validation, proving compliance with established medical device standards and functional specifications. No new clinical studies with patient data were required or conducted for this specific submission.

    Ask a Question

    Ask a specific question about this device

    K Number
    K251364

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-07-29

    (89 days)

    Product Code
    Regulation Number
    870.2300
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Switzerland

    Re: K251364
    Trade/Device Name: Sleepiz One+ (2.5)
    Regulation Number: 21 CFR 870.2300
    Cardiotachometer & Rate Alarm & Monitor, Breathing Frequency |
    | Regulation Number | 21 CFR 870.2300

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Sleepiz One+ is a contactless medical device intended to measure heart rate and respiration rate in adult patients, at rest or during sleep (in non-motion condition) and to detect patient presence and body movements.

    The Sleepiz One+ hardware unit is intended to be used by a healthcare professional when the recordings are performed in a clinical setting, or by patients or their caregivers when the recordings are performed in a home environment. The Sleepiz One+ cloud software is intended for use by healthcare professionals.

    This device is not indicated for active patient monitoring, as it does not provide alarms for timely response in life-threatening situations. It is not indicated for use on pregnant women or patients with active implantable devices.

    Device Description

    Sleepiz One+ is a contactless medical device that uses radar technology to measure respiration rate and heart rate from a resting or sleeping patient.

    The Sleepiz One+ consists of a hardware unit and cloud-based software The hardware unit can be positioned on a bedside table, mounted on a stand, or attached to the wall behind the patient's bed. It is designed to monitor physiological signals by detecting small body movements, such as those caused by breathing and heartbeat, using Doppler radar. The recorded signals are then transmitted via Wi-Fi to cloud-based software, where they are analyzed to obtain respiration rate, heart rate, and body movement. These outputs can be exposed via the Application Programming Interfaces (APIs) to allow healthcare professionals the review and annotation of the data and compilation of results into reports.

    Outputs

    • Breathing pattern
    • Instantaneous breathing rate [breaths per minute]
    • Breathing rate statistics (10th, 50th, and 90th quantiles) [breaths per minute]
    • Body movement
    • Time in bed [hours]
    • Presence detection
    • Heart rate [beats per minute]
    • Heart rate statistics (10th, 50th, and 90th quantiles) [beats per minute]

    The overall system can be grouped into 4 major components, which are classified on the basis of the logical component interfaces where data exchange is occurring.

    • Sleepiz Hardware - This is a hardware component serving as primary data acquisition device.
    • Embedded Software - This encompasses the firmware running of the Sleepiz Hardware. This, together with Sleepiz hardware, is responsible for data acquisition. The embedded software forms the crux of the Sleepiz hardware such that it defines and controls the data acquisition process. The security aspects related to the operation of the device are incorporated in the design and implementation of embedded software.
    • Sleep Analytics Software - The sleep analytics software is responsible for processing data from the Sleepiz Hardware and returning its analytics (e.g., breathing rate, heart rate), as well as its statistics (e.g., mean breathing rate, total recording time, etc.). This refers to the ML model deployed within the cloud software. By itself, the Sleep Analytics Software does not have an external interface. It is wholly encapsulated by the cloud software component Data Processing Layer.
    • Cloud Software - The cloud software can be divided into the backend service and the analytics service. The backend service includes modules for data ingestion, a public API, a private API, and a module for sending analysis process requests. The analytics service is responsible for receiving analysis requests and interacting with the sleep analytics software.
    AI/ML Overview

    The FDA 510(k) clearance letter for Sleepiz One+ (2.5) indicates that the device's substantial equivalence to a predicate device (Sleepiz One+) was established primarily through non-clinical performance testing, focusing on software verification and validation, electrical safety, and electromagnetic compatibility. The document states that the subject device and the predicate device have the same intended use, principle of operation, and similar technological characteristics. The minor modifications (API-based data access instead of web interface and plug-in power instead of battery) were assessed for safety and effectiveness without requiring extensive new clinical studies.

    The provided document does not detail specific acceptance criteria for the accuracy of heart rate and respiration rate measurements, nor does it provide a study proving the device meets these specific performance criteria. The clearance is based on the conclusion that "The verification and validation tests performed on the subject device confirm that the device performs as intended in the specified use conditions and comparably to the predicate device. The performance testing conducted shows comparable results between the two models, thereby, demonstrating the safety and performance of the Sleepiz One+ (V.2.5)."

    Therefore, based solely on the provided text, a comprehensive table of acceptance criteria and the detailed study proving the device's accuracy against those criteria cannot be constructed. The document infers that the device performs as intended and comparably to the predicate, but it does not present the raw performance data or the specific acceptance thresholds for heart rate and respiration rate accuracy.

    Here's a breakdown of the requested information based on the provided text, with clear indications where the information is NOT available.


    1. A table of acceptance criteria and the reported device performance

    Information NOT available in the provided text. The 510(k) summary states that "performance testing conducted shows comparable results between the two models," but it does not quantify these results or list specific acceptance criteria for heart rate and respiration rate accuracy. The testing primarily focused on software validation, electrical safety, and EMC.


    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    Information NOT available in the provided text. The document mentions "non-clinical performance tests" and "verification and validation tests," but it doesn't specify any sample sizes for a test set related to the accuracy of vital sign measurements, nor the provenance of any data used for such testing.


    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    Information NOT available in the provided text. There is no mention of external experts or ground truth establishment in the context of vital sign accuracy, as the clearance seems to rely on comparability to a predicate device and engineering verification/validation. For devices measuring physiological parameters, ground truth is typically established via reference medical devices (e.g., ECG, capnography) rather than expert consensus on subjective data.


    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Information NOT available in the provided text. Since no details on a clinical or performance study involving human subjects and expert review are provided, there is no mention of an adjudication method.


    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Information NOT available in the provided text. The Sleepiz One+ is a vital signs monitor, not typically an AI-assisted diagnostic imaging device that would undergo MRMC studies. The device primarily measures heart rate and respiration rate via radar and processes this data in cloud software (Sleep Analytics Software contains the ML model). The interaction is between the device and the patient, not a "human reader" interpreting AI outputs in a MRMC context. The cleared device provides raw data and statistics (like quantiles), which healthcare professionals would then interpret.


    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    The device's core function, measuring heart rate and respiration rate from radar signals using its Sleep Analytics Software (which contains the ML model), operates in a standalone manner to generate these outputs. The outputs themselves (instantaneous rates, statistics) are generated by the algorithm without human intervention in the loop of the measurement process itself. Healthcare professionals then access and interpret these results via API. The non-clinical performance testing would have validated the output of this standalone algorithm against internal specifications or a reference.


    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    Information NOT explicitly stated in the provided text regarding vital sign accuracy. For devices measuring heart rate and respiration rate, ground truth is typically established using established reference medical devices (e.g., synchronously recorded ECG for heart rate, capnography or impedance pneumography for respiration rate). While not stated, it can be inferred that if accuracy was evaluated, it would be against such objective physiological measurements rather than subjective expert consensus or pathology.


    8. The sample size for the training set

    The device uses an "ML model deployed within the cloud software" for "Sleep Analytics Software." However, the provided 510(k) summary does NOT provide any details about the training set size or methodology for this ML model. The focus of the substantial equivalence claim is on the overall system's safety and performance comparability to the predicate, with modifications primarily linked to data access and power source.


    9. How the ground truth for the training set was established

    Information NOT available in the provided text. As with the training set size, the 510(k) summary does not provide details on how the ground truth for the training set (if any specific to the ML model) was established.

    Ask a Question

    Ask a specific question about this device

    Why did this record match?
    510k Summary Text (Full-text Search) :

    . §870.2300 Cardiac monitor (including cardiotachometer and rate alarm).
    21 C.F.R. §868.1400 Carbon

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The monitor B105M, B125M, B155M, B105P and B125P are portable multi-parameter patient monitors intended to be used for monitoring, recording, and to generate alarms for multiple physiological parameters of adult, pediatric, and neonatal patients in a hospital environment and during intra-hospital transport.

    The monitor B105M, B125M, B155M, B105P and B125P are intended for use under the direct supervision of a licensed health care practitioner.

    The monitor B105M, B125M, B155M, B105P and B125P are not Apnea monitors (i.e., do not rely on the device for detection or alarm for the cessation of breathing). These devices should not be used for life sustaining/supporting purposes.

    The monitor B105M, B125M, B155M, B105P and B125P are not intended for use during MRI.

    The monitor B105M, B125M, B155M, B105P and B125P can be stand-alone monitors or interfaced to other devices via network.

    The monitor B105M, B125M, B155M, B105P and B125P monitor and display: ECG (including ST segment, arrhythmia detection, ECG diagnostic analysis and measurement), invasive blood pressure, heart/pulse rate, oscillometric non-invasive blood pressure (systolic, diastolic and mean arterial pressure), functional oxygen saturation (SpO2) and pulse rate via continuous monitoring (including monitoring during conditions of clinical patient motion or low perfusion), temperature with a reusable or disposable electronic thermometer for continual monitoring Esophageal/Nasopharyngeal/Tympanic/Rectal/Bladder/Axillary/Skin/Airway/Room/Myocardial/Core/Surface temperature, impedance respiration, respiration rate, airway gases (CO2, O2, N2O, anesthetic agents, anesthetic agent identification and respiratory rate), Cardiac Output (C.O.), Entropy, neuromuscular transmission (NMT) and Bispectral Index (BIS).

    The monitor B105M, B125M, B155M, B105P and B125P are able to detect and generate alarms for ECG arrhythmias: Asystole, Ventricular tachycardia, VT>2, Ventricular Bradycardia, Accelerated Ventricular Rhythm, Ventricular Couplet, Bigeminy, Trigeminy, "R on T", Tachycardia, Bradycardia, Pause, Atrial Fibrillation, Irregular, Multifocal PVCs, Missing Beat, SV Tachy, Premature Ventricular Contraction (PVC), Supra Ventricular Contraction (SVC) and Ventricular fibrillation.

    Device Description

    The proposed monitors B105M, B125M, B155M, B105P and B125P are new version of multi-parameter patient monitors developed based on the predicate monitors B105M, B125M, B155M, B105P and B125P (K213490) to provide additional monitored parameter Bispectral Index (BIS) by supporting the additional optional E-BIS module (K052145) which used in conjunction with Covidien BISx module (K072286).

    In addition to the added parameter, the proposed monitors also offer below several enhancements:

    • Provided data connection with GE HealthCare anesthesia devices to display the parameters measured from anesthesia devices (Applicable for B105M, B125M and B155M).
    • Modified Early Warning Score calculation provided.
    • Separated low priority alarms user configurable settings from the combined High/Medium/Low priority options.
    • Provided additional customized notification tool to allow clinician to configure the specific notification condition of one or more physiological parameters measured by the monitor. (Applicable for B105M, B125M and B155M).
    • Enhanced User Interface in Neuromuscular Transmission (NMT), Respiration Rate and alarm overview.
    • Provided Venous Stasis to assist venous catheterization with NIBP cuff inflation.
    • Supported alarm light brightness adjustment.
    • Supported alarm audio pause by gesture (Not applicable for B105M and B105P).
    • Supported automatic screen brightness adjustment.
    • Supported network laser printing.
    • Continuous improvements in cybersecurity

    The proposed monitors B105M, B125M, B155M, B105P and B125P retain equivalent hardware design based on the predicate monitors and removal of the device Trim-knob to better support cleaning and disinfecting while maintaining the same primary function and operation.

    Same as the predicate device, the five models (B105M, B125M, B155M, B105P and B125P) share the same hardware platform and software platform to support the data acquisition and algorithm modules. The differences between them are the LCD screen size and configuration options. There is no change from the predicate in the display size.

    As with the predicate monitors B105M, B125M, B155M, B105P and B125P (K213490), the proposed monitors B105M, B125M, B155M, B105P and B125P are multi-parameter patient monitors, utilizing an LCD display and pre-configuration basic parameters: ECG, RESP, NIBP, IBP, TEMP, SpO2, and optional parameters which include CO2 and Gas parameters provided by the E-MiniC module (K052582), CARESCAPE Respiratory modules E-sCO and E-sCAiO (K171028), Airway Gas Option module N-CAiO (K151063), Entropy parameter provided by the E-Entropy module (K150298), Cardiac Output parameter provided by the E-COP module (K052976), Neuromuscular Transmission (NMT) parameter provided by E-NMT module (K051635) and thermal recorder B1X5-REC.

    The proposed monitors B105M, B125M, B155M, B105P and B125P are not Apnea monitors (i.e., do not rely on the device for detection or alarm for the cessation of breathing). These devices should not be used for life sustaining/supporting purposes. Do not attempt to use these devices to detect sleep apnea.

    As with the predicate monitors B105M, B125M, B155M, B105P and B125P (K213490), the proposed monitors B105M, B125M, B155M, B105P and B125P also can interface with a variety of existing central station systems via a cabled or wireless network which implemented with identical integrated WiFi module. (WiFi feature is disabled in B125P/B105P).

    Moreover, same as the predicate monitors B105M, B125M, B155M, B105P and B125P (K213490), the proposed monitors B105M, B125M, B155M, B105P and B125P include features and subsystems that are optional or configurable, and it can be mounted in a variety of ways (e.g., shelf, countertop, table, wall, pole, or head/foot board) using existing mounting accessories.

    AI/ML Overview

    The provided FDA 510(k) clearance letter and summary for K242562 (Monitor B105M, Monitor B125M, Monitor B155M, Monitor B105P, Monitor B125P) do not contain information about specific acceptance criteria, reported device performance metrics, or details of a study meeting those criteria for any of the listed physiological parameters or functionalities (e.g., ECG or arrhythmia detection).

    Instead, the documentation primarily focuses on demonstrating substantial equivalence to a predicate device (K213490) by comparing features, technology, and compliance with various recognized standards and guidance documents for safety, EMC, software, human factors, and cybersecurity.

    The summary explicitly states: "The subject of this premarket submission, the proposed monitors B105M/B125M/B155M/B105P/B125P did not require clinical studies to support substantial equivalence." This implies that the changes introduced in the new device versions were not considered significant enough to warrant new clinical performance studies or specific quantitative efficacy/accuracy acceptance criteria beyond what is covered by the referenced consensus standards.

    Therefore, I cannot provide the requested information from the given text:

    1. A table of acceptance criteria and the reported device performance: This information is not present. The document lists numerous standards and tests performed, but not specific performance metrics or acceptance thresholds.
    2. Sample size used for the test set and the data provenance: Not explicitly stated for performance evaluation, as clinical studies were not required. The usability testing mentioned a sample size of 16 US clinical users, but this is for human factors, not device performance.
    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable, as detailed performance studies requiring expert ground truth are not described.
    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set: Not applicable.
    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. This device is a patient monitor, not an AI-assisted diagnostic tool that would typically involve human readers.
    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done: The document describes "Bench testing related to software, hardware and performance including applicable consensus standards," which implies standalone testing against known specifications or simulated data. However, specific results or detailed methodologies for this type of testing are not provided beyond the list of standards.
    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.): Not explicitly stated for performance assessment. For the various parameters (ECG, NIBP, SpO2, etc.), it would typically involve reference equipment or validated methods as per the relevant IEC/ISO standards mentioned.
    8. The sample size for the training set: Not applicable, as this is not an AI/ML device that would require explicit training data in the context of this submission.
    9. How the ground truth for the training set was established: Not applicable.

    In summary, the provided document focuses on demonstrating that the new monitors are substantially equivalent to their predicate through feature comparison, adherence to recognized standards, and various non-clinical bench tests (e.g., hardware, alarms, EMC, environmental, reprocessing, human factors, software, cybersecurity). It does not contain the detailed performance study results and acceptance criteria typically found for novel diagnostic algorithms or AI-driven devices.

    Ask a Question

    Ask a specific question about this device

    K Number
    K242737

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-06-06

    (268 days)

    Product Code
    Regulation Number
    870.2300
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Health Monitoring Platform; EmbracePlus; Empatica Care; Care Portal
    Regulation Number: 21 CFR 870.2300
    Classification Name | Device Class | Product Code | Classification Panel |
    |---|---|---|---|---|
    | 870.2300

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Empatica Health Monitoring Platform is a wearable device and paired mobile and cloud-based software platform intended to be used by trained healthcare professionals or researchers for retrospective remote monitoring of physiologic parameters in ambulatory individuals 18 years of age and older in home-healthcare environments. As the platform does not provide real-time alerts related to variation of physiologic parameters, users should use professional judgment in assessing patient clinical stability and the appropriateness of using a monitoring platform designed for retrospective review.

    The device is intended for continuous data collection supporting intermittent retrospective review of the following physiological parameters:

    • Pulse Rate,
    • Blood Oxygen Saturation under no-motion conditions,
    • Respiratory Rate under no motion conditions,
    • Peripheral Skin Temperature,
    • Electrodermal Activity,
    • Activity associated with movement during sleep

    The Empatica Health Monitoring Platform can be used to analyze circadian rhythms and assess activity in any instance where quantifiable analysis of physical motion is desirable.

    The Empatica Health Monitoring Platform is not intended for SpO2 monitoring in conditions of motion or low perfusion.

    The Empatica Health Monitoring Platform is intended for peripheral skin temperature monitoring, where monitoring temperature at the wrist is clinically indicated.

    The Empatica Health Monitoring Platform is not intended for Respiratory Rate monitoring in motion conditions. This device does not detect apnea and should not be used for detecting or monitoring cessation of breathing.

    The Empatica Health Monitoring Platform is not intended for Pulse Rate monitoring in patients with chronic cardiac arrhythmias, including atrial fibrillation and atrial/ventricular bigeminy and trigeminy, and is not intended to diagnose or analyze cardiac arrhythmias. The Empatica Health Monitoring Platform is not a substitute for an ECG monitor, and should not be used as the sole basis for clinical decision-making.

    Device Description

    The Empatica Health Monitoring Platform is a wearable device and software platform composed by:

    • A wearable medical device called EmbracePlus,
    • A mobile application running on smartphones called "Care App",
    • A cloud-based software platform named "Care Portal".

    The EmbracePlus is worn on the user's wrist and continuously collects raw data via specific sensors. These data are wirelessly transmitted via Bluetooth Low Energy to a paired mobile device where the Care App is up and running. The data received are analyzed by one of the Care App software modules, EmpaDSP, which computes the user physiological parameters. Based on the version of the Care App installed, the user can visualize a subset of these physiological parameters. The Care App is also responsible for transmitting, over cellular or WiFi connection sensors' raw data, device information, Care App-specific information, and computed physiological parameters to the Empatica Cloud. On the Empatica Cloud, these data are stored, further analyzed, and accessible by healthcare providers or researchers via a specific cloud-based software called Care Portal.

    The Empatica Health Monitoring Platform is intended for retrospective remote monitoring of physiological parameters in ambulatory adults in home-healthcare environments. It is designed to continuously collect data to support intermittent monitoring of the following physiological parameters and digital biomarkers by trained healthcare professionals or researchers: Pulse Rate (PR), Respiratory Rate (RR), blood oxygen saturation (SpO2), peripheral skin temperature (TEMP), and electrodermal activity (EDA). Activity sensors are used to detect sleep periods and to monitor the activity associated with movement during sleep.

    AI/ML Overview

    The provided FDA 510(k) clearance letter and its attachments describe the acceptance criteria and study that proves the Empatica Health Monitoring Platform (EHMP) meets those criteria, specifically concerning a new Predetermined Change Control Plan (PCCP) for the SpO2 quality indicator (QI) algorithm.

    1. Acceptance Criteria and Reported Device Performance

    The acceptance criteria are outlined for the proposed modification to the SpO2 Quality Indicator (QI) algorithm. The reported device performance is presented as a statement of equivalence to the predicate device, implying that the acceptance criteria are met, as the 510(k) was cleared.

    MetricAcceptance CriteriaReported Device Performance
    SpO2 QI Algorithm - Bench TestingSensitivity, Specificity, and False Discovery Rate of the modified SpO2 QI algorithm in discriminating low-quality and high-quality data are non-inferior to the SpO2 QI in the FDA-cleared SpO2 algorithm.Implied to have met criteria, as the device received 510(k) clearance. Full performance metrics are not explicitly stated in this document but are described as being non-inferior.
    SpO2 Algorithm - Clinical Testing (Arms Error)The Arms error of the modified SpO2 algorithm is lower or equivalent to the FDA-cleared SpO2 algorithm.Implied to have met criteria, as the device received 510(k) clearance. Full performance metrics are not explicitly stated in this document but are described as being lower or equivalent.
    SpO2 QI Algorithm - Clinical Testing (Percent Agreement)The percent agreement between the modified SpO2 QI outputs and the FDA-cleared SpO2 QI outputs must be equal to or higher than 90%.Implied to have met criteria, as the device received 510(k) clearance. Full performance metrics are not explicitly stated in this document but are described as being equal to or higher than 90%.
    Software Verification TestsAll software verification tests linked to requirements and specifications must pass.Implied to have met criteria, as the device received 510(k) clearance.

    Note: For the pre-existing functionalities (Pulse Rate, Respiratory Rate, Peripheral Skin Temperature, Electrodermal Activity, Activity and Sleep), the document states that "no changes to the computation... compared with the cleared version" have been introduced, implying their previous acceptance criteria were met and remain valid.

    2. Sample Sizes and Data Provenance

    • Test Set Sample Size: Not explicitly stated for the SpO2 algorithm modification. The document only mentions "enhancing the development dataset with new samples" for the ML-based algorithm and clinical testing was "conducted in accordance with ISO 80601-2-61... and ... FDA Guidelines for Pulse Oximeters." These standards typically require a certain number of subjects and data points, but the exact numbers are not provided in this public summary.
    • Data Provenance: Not specified in the provided document. It does not mention the country of origin, nor whether the data was retrospective or prospective.

    3. Number and Qualifications of Experts for Ground Truth

    • Number of Experts: Not specified.
    • Qualifications of Experts: Not specified. The document states the platform is "intended to be used by trained healthcare professionals or researchers," and later discusses "professional users" and "clinical interpretation," implying that the ground truth for clinical studies would likely involve such experts, but their specific roles, numbers, and qualifications for establishing ground truth are not detailed.

    4. Adjudication Method for the Test Set

    The adjudication method for establishing ground truth for the test set is not explicitly mentioned in the provided document.

    5. Multi Reader Multi Case (MRMC) Comparative Effectiveness Study

    There is no mention of a Multi Reader Multi Case (MRMC) comparative effectiveness study being conducted, nor any effect size regarding human readers improving with AI vs. without AI assistance. The device is for "retrospective remote monitoring" by healthcare professionals, implying an AI-driven data collection/analysis with human review, but not necessarily human-AI collaboration in real-time diagnostic interpretation that an MRMC study would evaluate.

    6. Standalone (Algorithm Only) Performance

    The acceptance criteria for the SpO2 QI algorithm include "Bench testing conducted using a functional tester to simulate a range of representative signal quality issues." This falls under standalone performance, as it tests the algorithm's ability to discriminate data quality without direct human input. Clinical testing also evaluates the algorithm's accuracy (Arms error) in comparison to an established standard, which is also a standalone performance measure.

    7. Type of Ground Truth Used

    • For the SpO2 QI ML algorithm: The ground truth for low-quality and high-quality data discrimination seems to be an internal standard/reference based on the "FDA-cleared SpO2 algorithm" and potentially expert labeling of data quality during the "enhancing the development dataset."
    • For the SpO2 Accuracy (Arms Error): The ground truth for SpO2 values would be established in accordance with ISO 80601-2-61, which typically involves comparing the device's readings against a laboratory co-oximeter or a reference pulse oximeter for arterial oxygen saturation.

    8. Sample Size for the Training Set

    The document mentions "enhancing the development dataset with new samples" for the ML-based algorithm but does not specify the sample size for the training set.

    9. How Ground Truth for Training Set was Established

    The ground truth for training the ML-based SpO2 QI algorithm was established by "enhancing the development dataset with new samples." It also mentions performing "feature extraction and engineering on window lengths spanning a 10-30-second range." While it doesn't explicitly state the methodology, given the context of a "binary output" (high/low quality), it implies a labeling process, likely by human experts or based on predefined criteria derived from the previous FDA-cleared algorithm's performance on various data types. For the SpO2 accuracy, the ground truth would typically be established by a reference method consistent with the mentioned ISO standard and FDA guidance.

    Ask a Question

    Ask a specific question about this device

    K Number
    K242750

    Validate with FDA (Live)

    Device Name
    Central Station
    Date Cleared
    2025-06-05

    (266 days)

    Product Code
    Regulation Number
    870.2300
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    California 92618

    Re: K242750
    Trade/Device Name: Central Station
    Regulation Number: 21 CFR 870.2300
    Medical Specialty:** Cardiovascular
    Classification Panel: Cardiovascular
    Regulation Number: 870.2300
    II (performance standards) | Class II (performance standards) | Same |
    | Regulatory Number | 21CFR 870.2300

    • Cardiac monitor (including cardiotachometer and rate alarm) | 21CFR 870.2300- Cardiac monitor (including
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Central Station is a network device, intended to display, record and print monitored physiological data from Nihon Kohden bedside monitors, telemetry receiver and/or transmitters.

    Central Station does not perform any data processing on the data received from the Nihon Kohden compatible devices. When Central Station is connected with the Nihon Kohden bedside monitors and telemetry receivers/transmitters the Central Station can:
    • Admit and discharge patients on the Nihon Kohden network.
    • Display and manage compatible devices' real-time patient clinical data, vital signs, alarms and waveforms.
    • Review and trend data calculated by connected Nihon Kohden devices.
    • Store and transfer historical clinical data for the connected systems.
    • Print patient data.

    Central Station is intended for use in professional medical facilities by trained medical personnel.

    Device Description

    Central Station is software only product that is installed on a Commercial Off the Shelf (COTS) Computer.

    Central Station displays waveforms data and numerical data from a connected bedside monitor, vital sign telemeter, or multiple patient receiver unit on the screen.

    Central Station is a network device, intended to provide remote patient monitoring to medical personnel. Central Station displays a list of measured values and a trend graph. Numerical data and various waveforms are color-coded for each parameter. Central Station also has the function of displaying an alarm.

    Alarm indication in Central Station is displayed as a result of a judgment by the bedside monitor, vital sign telemeter, or multiple patient receiver units connected to the Central Station. Central Station itself does not have the function to perform alarm indication judgment.

    AI/ML Overview

    The provided document is a 510(k) clearance letter for the "Central Station" device. This type of document primarily focuses on establishing substantial equivalence to a legally marketed predicate device rather than detailing specific performance acceptance criteria and study results in the same way as a full clinical trial report or a detailed design validation report would.

    The document states:

    • "Central Station does not perform any data processing on the data received from the Nihon Kohden compatible devices."
    • "Alarm indication in Central Station is displayed as a result of a judgment by the bedside monitor, vital sign telemeter, or multiple patient receiver units connected to the Central Station. Central Station itself does not have the function to perform alarm indication judgment."
    • "The results of the substantial equivalence assessment, taken together with non-clinical bench testing, software verification, and validation demonstrate that the Central station does not raise concerns regarding its safety and effectiveness compared to its predicate device and operates in accordance with claimed indications for use."

    Given these statements, the "Central Station" device is essentially a display, recording, and communication hub. It does not perform diagnostic algorithms or make independent judgments that would typically necessitate the kinds of detailed performance metrics (like sensitivity, specificity, or reader agreement) that are usually established through extensive multi-reader, multi-case (MRMC) studies with expert ground truth. Its primary function is to accurately display and relay data processed by other Nihon Kohden devices.

    Therefore, the "acceptance criteria" and "study that proves the device meets the acceptance criteria" for this specific device (Central Station) would primarily revolve around:

    • Software Verification and Validation (V&V): Ensuring the software correctly displays, records, and transmits data as designed, and that all features (admit/discharge, trend display, printing, network communication) function as intended without errors.
    • Non-Clinical Bench Testing: Confirming interoperability with compatible devices, accuracy of data display, alarm relay, and network functionality.
    • Cybersecurity Compliance: Meeting regulatory requirements for cybersecurity.

    The document explicitly states that "The software documentation was prepared following the FDA's 'Guidance for the Content of Premarket Submissions for Software Contained in Medical Devices' (released June 14, 2023), specifically for an Enhanced Documentation Level." and "Verification testing was conducted at the system integration level to confirm that the device software fulfills its requirements and that safety and security risk mitigations, where applicable, were effective. Additionally, system-level testing was carried out to show that the software addresses user needs. All unit, integration, and system-level tests successfully met the test protocols."

    Based on the provided text, it is not possible to extract the specific quantitative performance metrics (like sensitivity, specificity, or effect sizes for human readers) that would be relevant for a device performing complex data processing or diagnostic functions. The document emphasizes substantial equivalence and basic functional verification, not advanced AI/diagnostic performance validation.

    However, I can infer the spirit of typical acceptance criteria and how a device like this would be proven to meet them, guided by the information provided.


    Inferred Acceptance Criteria and Device Performance for "Central Station"

    Given the device's stated function (display, record, print, and relay data without processing it for diagnosis or alarm judgment), the acceptance criteria would focus on functional correctness, data integrity, interoperability, and system reliability, rather than diagnostic accuracy metrics.

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategorySpecific Acceptance Criteria (Inferred)Reported Device Performance (Inferred from document)
    Functional Performance1. Data Display Accuracy: All physiological data (waveforms, numerics, alarms) received from connected compatible devices are accurately and synchronously displayed."Display and manage compatible devices' real-time patient clinical data, vital signs, alarms and waveforms." "Numeric data and various waveforms are color-coded for each parameter." Implied: Accuracy of display confirmed via functional tests against known inputs from connected devices.
    2. Data Recording & Storage: Historical clinical data, trends, and events are accurately stored and retrievable for the specified durations/files."Store and transfer historical clinical data for the connected systems." Review history data storage (e.g., Trendgraph: 120 hours, Arrhythmia recall: 1,500 files, Event list: 10,000 files). Implied: Storage and retrieval validated against specified capacities and data integrity checks.
    3. Printing Functionality: Patient data can be accurately printed, including specified parameters like patient info, waveforms, and trends."Print patient data." Ability to print various review windows (Trend, Full Disclosure, Arrhythmia Recall, etc.). Implied: Printing validated for completeness and accuracy of generated reports.
    4. Patient Management: Functions for admitting, discharging, pausing, and transferring patients within the network operate correctly."Admit and discharge patients on the Nihon Kohden network." Support for Admit, Discharge, Pause, Transfer functions (within one CS, between CSs, manual/auto entry). Implied: Workflow and data handling for patient management validated.
    5. Alarm Relay: Alarms generated by connected bedside monitors are accurately received and displayed/mimicked by Central Station."Alarm indication in Central Station is displayed as a result of a judgment by the bedside monitor... Central Station itself does not have the function to perform alarm indication judgment." Implied: Alarms from connected devices are correctly received and presented as per design.
    Interoperability & Connectivity1. Compatible Device Connection: Successful and stable connection to all specified Nihon Kohden bedside monitors, telemetry receivers/transmitters.Compatible with NK Bedside Monitors (BSM: 1700, 3000, 6000, G9, G5, G7), Vital Signs Monitor (SVM-7200), NK Telemetry (GZ-120/130/140), Multiple Patient Receiver/Transmitters (ORG-9700/9100, ZS-940, ZM-520/521/530/531), Central Monitor (CNS-6201/6801/2101). Max 32 connections. Implied: Connectivity and data exchange verified through testing with all listed compatible devices.
    2. Network Communication: Reliable communication via NET-9/LS-NET protocol within the Nihon Kohden network."Network: Yes (NK Network)." "Communication protocol: NET-9/LS-NET communication." Implied: Network communication validated for stability, data integrity, and compliance with protocol.
    Software Quality & Reliability1. Software Functionality: All software features operate as per specifications without critical errors or crashes."Verification testing was conducted at the system integration level to confirm that the device software fulfills its requirements... All unit, integration, and system-level tests successfully met the test protocols." Implied: Comprehensive software V&V confirmed functional correctness and absence of defects.
    2. Cybersecurity: Device adequately mitigates cybersecurity risks and complies with relevant guidance."Cybersecurity information has been provided in line with the FDA's 'Cybersecurity in Medical Devices: Quality System Considerations and Content of Premarket Submissions' guidance document, dated September 27, 2023." "Interoperability-related risk management activities are included in Cybersecurity Risk Management activities." Implied: Security testing confirmed adherence to cybersecurity standards.
    Risk Management1. Safety & Effectiveness: Risks associated with interoperability, anticipated users, and foreseeable misuse are adequately addressed."The CENTRAL STATION has been designed and verified through a risk analysis that considers the risks associated with interoperability, the anticipated users, reasonably foreseeable misuse, and reasonably foreseeable combinations of events that can result in a hazardous situation." Implied: Risk analysis documented and mitigation verified, ensuring the device does not raise new safety/effectiveness concerns compared to the predicate.

    2. Sample Size and Data Provenance

    • Test Set Sample Size: Not explicitly stated as a "sample size" in the context of patient data for diagnostic algorithms, because the device doesn't perform diagnostic processing. The "test set" for this device would be a collection of test cases covering all functional requirements, interoperability scenarios with different compatible devices, alarm conditions (relayed), data storage limits, network loads, and user interaction flows. The document mentions "system integration level" and "system-level testing" and that "all unit, integration, and system-level tests successfully met the test protocols." This implies a comprehensive set of non-clinical, bench-level tests.
    • Data Provenance: Not applicable in the sense of clinical patient data (e.g., from specific countries, retrospective/prospective studies), as the device does not process primary patient data for diagnosis. The data used for testing would be simulated, generated, or derived from compatible Nihon Kohden monitor outputs in a lab setting to verify the Central Station's display and communication functions.

    3. Number of Experts and Qualifications for Ground Truth

    • Not Applicable in the traditional sense for diagnostic AI. The ground truth for this device's performance would be the expected output based on its functional specifications and the known inputs from the connected Nihon Kohden devices. For example, if a connected monitor transmits an HR of 70 bpm, the ground truth is that the Central Station must display 70 bpm. These "ground truths" are established by engineering design specifications, not human expert consensus on clinical findings.
    • Experts Involved: Software engineers, quality assurance engineers, subject matter experts on the physiological monitoring systems, and potentially clinical users for usability and workflow testing. Their qualifications would be in device design, software development, testing, and clinical application.

    4. Adjudication Method for the Test Set

    • Not Applicable in the context of clinical interpretation adjudication (e.g., 2+1 radiologist consensus). Adjudication in this context would be internal to the software development and testing process:
      • Test Pass/Fail Criteria: Predetermined pass/fail criteria for each test case.
      • Bug/Defect Resolution: Issues found during testing are logged as bugs, investigated by engineers, and resolved, followed by retesting.
      • Verification Sign-off: Test leads or design engineers review test results and formally sign off on the successful completion of verification.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • No, not performed for this device. An MRMC study is relevant for AI systems that assist human readers in making diagnostic decisions (e.g., radiologists reading X-rays with AI assistance). The Central Station device does not perform any such diagnostic assistance; it merely displays data from other (likely already cleared) devices. Its function is analogous to a monitor or a remote display unit, not a diagnostic AI.

    6. Standalone (Algorithm Only) Performance

    • Not Applicable. This device does not have a "standalone algorithm" that performs diagnostic or data processing functions independently. Its function is entirely dependent on receiving data from other compatible Nihon Kohden devices.

    7. Type of Ground Truth Used

    • Functional Specifications and Truth from Connected Devices: The ground truth for this device is based on its functional design specifications (e.g., "display received data," "store data for X hours," "print Y parameters") and the verified output from the connected Nihon Kohden bedside monitors and telemetry systems. It's about data integrity and display accuracy, not clinical outcomes or pathology.

    8. Sample Size for the Training Set

    • Not Applicable. This device is described as "software only product" that "does not perform any data processing on the data received," and "Central Station itself does not have the function to perform alarm indication judgment." This strongly implies it is a rule-based or deterministic system, not a machine learning/AI system that requires a "training set" in the common sense (i.e., for learning patterns from data for prediction or classification). Therefore, there is no training set.

    9. How the Ground Truth for the Training Set Was Established

    • Not Applicable. As there is no training set for an AI algorithm, there is no corresponding ground truth establishment process for a training set.