510(k) Data Aggregation

    Why did this record match?
    Reference Devices :

    K974054, K791125, K812672, K091967, K962101, K980843

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Components of the Signature Orthopaedics hip replacement range are intended to replace a hip joint where bone stock is sufficient to support the implant. When a surgeon has selected prosthetic replacement as the preferred treatment, the devices are indicated for:

    • Non-inflammatory degenerative joint disease including osteoarthritis or avascular necrosis
    • Inflammatory joint disease including rheumatoid arthritis
    • Correction of functional deformity including congenital hip dysplasia
    • Traumatic injury involving the hip joint including traumatic arthritis or femoral head or neck fracture
    • Failed previous hip surgery including internal fixation or joint fusion, reconstruction, hemiarthroplasty, surface replacement, or total replacement

    Signature Orthopaedics' Origin, NEO-T, Remedy and Pegasus femoral stems, and Logical acetabular cups are intended for cementless fixation only. Signature Orthopaedics' Evolve femoral stems are intended for cemented fixation only.

    Signature Orthopaedics' BiPolar Head is intended for hemi-hip arthroplasty only, where the natural acetabulum does not require replacement. The BiPolar Head is indicated for bone fractures or pathologies involving only the femoral head/neck and/or proximal femur, such as:

    • Acute femoral head or neck fracture
    • Fracture dislocation of the hip
    • Avascular necrosis of the femoral head
    • Non-union of femoral neck fractures
    • Certain high subcapital and femoral neck fractures in the elderly
    • Degenerative arthritis involving only the femoral head
    Device Description

    The Remedy™ and Pegasus™ hip stems are intended for cementless use in total hip arthroplasty. The Evolve™ hip stem is intended for cemented total hip arthroplasty. The Remedy™, Pegasus™ and Evolve™ hip stems connect to a femoral head (cobalt-chrome alloy or ceramic) via 12/14 taper connection.

    The Remedy™ Hip Stem has a tapered wedge geometry. The stem is manufactured from titanium alloy per ASTM F136. The proximal stem is porous coated with titanium beads and particles per ASTM F67 and the distal stem is matte finished.

    The Pegasus™ is a double tapered, straight stem with rectangular cross-section. The stem has a lateral wing for engaging the greater trochanter. The stem is manufactured from titanium alloy per ASTM F136. The stem is grit blasted below the resection line.

    The Evolve™ Hip Stem is a highly polished, tapered wedge stem with a rounded crosssection. The Evolve™ Hip Stem is manufactured from high nitrogen stainless steel per ISO 5832-9. The Evolve™ Hip Stem is available in two variants, the Masters series and the Helios Series. Both variants share similar general geometry but are sized differently to provide a more complete range. The Evolve™ Hip Stem includes two accessories, the Evolve™ Distal Centralizer and Evolve™ Cement Plug. The Evolve™ Distal Centralizer is a PMMA cap that sits on the end of the Evolve™ Hip Stem and centralizes it within the femoral canal. The Evolve™ Cement Plug is manufactured from polyethylene per ASTM F648 and is pressed into the femoral canal prior to inserting the Evolve™ Hip Stem to allow cement pressurization.

    The BiPolar Head consists of a stainless steel outer shell (per ISO5832-9) and a UHMWPE insert (per ASTM F648). The outer shell is highly polished to articulate against the patient's natural acetabulum. The insert articulates against a Signature Orthopaedics 28mm cobalt-chrome femoral head (K121297). The 28mm femoral head connects to a femoral stem from Signature Orthopaedics' range to complete the hip hemiarthroplasty.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for various hip implants (Remedy™, Pegasus™ and Evolve™ Hip Stems and BiPolar Head) and details the non-clinical performance testing conducted to support their substantial equivalence claim to predicate devices. It does not present acceptance criteria in a quantitative format, nor does it detail a clinical study with a control group or human readers.

    Here's an analysis of the requested information based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    The document does not explicitly state quantitative acceptance criteria in a table format. Instead, it lists general performance tests conducted and then concludes that "Non-clinical testing results support the substantial equivalence claim. The RemedyTM, Pegasus™ and Evolve™ Hip Stems and BiPolar Head are expected to perform adequately during clinical use."

    The performance tests conducted include:

    Acceptance Criteria (Implied)Reported Device Performance
    Adequate Range of MotionVerified
    Sufficient Component Connection StrengthVerified
    Low Fretting CorrosionVerified
    Ceramic Head Burst ResistanceVerified
    Femoral Stem Fatigue ResistanceVerified
    Adequate Coating CharacterizationVerified
    Adequate Abrasion Resistance of CoatingVerified
    Adequate Adhesion Strength of CoatingVerified
    Sufficient BiPolar Head Disclamping ResistanceVerified

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document refers to "non-clinical testing and engineering evaluations." This implies in-vitro or bench testing, not patient data. Therefore, concepts like sample size, country of origin, or retrospective/prospective for a patient-based test set are not applicable here. The "test set" would consist of the orthopedic implants subjected to the various physical and mechanical tests. The sample sizes for each specific test are not reported. The company is Australia-based (Signature Orthopaedics Pty Ltd, Lane Cove, NSW 2066, Australia).

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This question is not applicable. The device is a physical hip implant. "Ground truth" in this context would refer to the physical and mechanical properties of the device as measured by engineering standards, not expert interpretations of medical images or clinical outcomes.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This question is not applicable as the evaluation involves non-clinical engineering tests, not human interpretation or adjudication of medical data.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    No, a multi-reader multi-case (MRMC) comparative effectiveness study was not done. This type of study is relevant for diagnostic devices that involve human interpretation of medical images, often with AI assistance. The document describes hip implants, which are surgical devices, and the testing performed is non-clinical engineering evaluation.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    No, a standalone algorithm performance study was not done. This question is also relevant for AI/software as a medical device (SaMD) and does not apply to physical hip implants.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    For this type of device, the "ground truth" for the non-clinical testing refers to established engineering standards, material properties, and biomechanical principles. For example, fatigue testing would compare the device's performance against known limits for medical implants, and material characterization would be compared against ASTM or ISO standards.

    8. The sample size for the training set

    This question is not applicable. There is no "training set" as this is not an AI/machine learning device. The "training" in this context would imply the manufacturing and design process of the device itself and the various components.

    9. How the ground truth for the training set was established

    This question is not applicable for the same reason as point 8. The "ground truth" for the design and manufacturing of the implants would be established through engineering specifications, material selection criteria based on ISO/ASTM standards, and biomechanical research for hip implant design.

    Ask a Question

    Ask a specific question about this device

    K Number
    K123991

    Validate with FDA (Live)

    Date Cleared
    2013-09-16

    (264 days)

    Product Code
    Regulation Number
    888.3390
    Age Range
    All
    Reference & Predicate Devices
    Why did this record match?
    Reference Devices :

    K120362, K113242, K111193, K812672, K903084

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Total Hip Arthroplasty and Hemi Hip Arthroplasty

    Total hip replacement or hip arthroplasty is indicated in the following conditions:

    1. A severely painful and/or disabled joint from osteoarthritis, traumatic arthritis, rheumatoid arthritis, or congenital hip dysplasia.
    2. Avascular necrosis of the femoral head.
    3. Acute traumatic fracture of the femoral head or neck.
    4. Failed previous hip surgery including joint reconstruction, internal fixation, arthrodesis, hemi-arthroplasty, surface replacement arthroplasty, or total hip replacement.
    5. Certain cases of ankylosis.

    Partial hip replacement or hip hemi-arthroplasty is indicated in the following conditions:

    1. Acute fracture of the femoral head or neck that cannot be appropriately reduced and treated with internal fixation.
    2. Fracture dislocation of the hip that cannot be appropriately reduced and treated with internal fixation.
    3. Avascular necrosis of the femoral head.
    4. Non-union of femoral neck fractures.
    5. Certain high subcapital and femoral neck fractures in the elderly.
    6. Degenerative arthritis involving only the femoral head in which the acetabulum does not require replacement.
    7. Pathology involving only the femoral head/neck and/or proximal femur that can be adequately treated by hip hemi-arthroplasty.

    HA coated stems of the Corail Hip System are indicated for cementless use only.

    Device Description

    The Corail AMT Hip is a tapered stem available both collarless and collared. The stems are manufactured from titanium alloy (Ti6Al4V) and plasma-sprayed with a biocompatible hydroxyapatite (HA) coating for bone fixation. The Corail AMT stems feature a 12/14 modular taper that accepts 12/14 heads with a wide range of diameters. The compatible components for the hip hemi-arthroplasty application are bipolar heads cleared via 510(k) K812672 and unipolar heads cleared via 510(k) K903084. Corail AMT stems are indicated for cementless use only.

    AI/ML Overview

    The provided document describes the Corail AMTTM Hip Prosthesis, an orthopaedic device. The submission is a 510(k) to expand the cleared indication for use to include hip hemi-arthroplasty surgical application.

    Here's an analysis of the acceptance criteria and the study that proves the device meets them:

    1. A table of acceptance criteria and the reported device performance

    Acceptance Criteria CategorySpecific Test/CharacteristicAcceptance CriteriaReported Device Performance
    MaterialCompositionTi-6Al-4VTi-6Al-4V (Same as predicate)
    Stem SurfaceCoating for bone fixationPlasma-sprayed with biocompatible hydroxyapatite (HA) coatingPlasma-sprayed with biocompatible hydroxyapatite (HA) coating (Same as predicate)
    Compatible Femoral HeadsTypes of heads acceptedBipolar and UnipolarBipolar and Unipolar (Same as predicate)
    Taper DesignModular Taper12/14 taper12/14 taper (Same as predicate)
    PlacementMethod of implantationPress Fit: CementlessPress Fit: Cementless (Same as predicate)
    Performance DataValidation of taper/heads dimensional compatibilityImplied to perform acceptably for mechanical matingPerformed as "Validation of the taper/heads dimensional compatibility with Corail AMT Stems"
    Performance DataFatigue ResistanceImplied to withstand anticipated physiological loads and cyclesPerformed as "Fatigue Resistance tests for the Corail AMT Stems"
    Clinical Equivalence (for expanded indication)Safety and effectiveness for hip hemi-arthroplastySubstantial equivalence to predicate devices and supported by existing clinical literatureSupported by a systematic literature review of Corail Hip System for femoral neck fractures, demonstrating no fundamental change in scientific technology and consistency with established safety and effectiveness.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Non-clinical (Performance) Tests: The document does not specify the exact sample sizes (number of devices tested) for the "Validation of the taper/heads dimensional compatibility" or the "Fatigue Resistance tests." It only states that these tests were performed. Given the nature of these tests, they would typically involve a defined number of test articles to meet industry standards (e.g., ISO or ASTM standards for implant testing).
    • Clinical Evaluation: No new clinical tests were conducted. The clinical evaluation utilized a "systematic literature review of Corail Hip System for the treatment of femoral neck fractures." The provenance of the data in this systematic review would depend on the included studies, but the document does not provide details on country of origin or whether these studies were retrospective or prospective. It is a compilation of retrospective existing scientific literature.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    Not applicable. This submission relies on non-clinical performance testing and a literature review for clinical evaluation, not on a test set requiring expert ground truth for interpretation of images or other data.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable. There was no clinical test set requiring expert adjudication.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is a medical device for hip arthroplasty, not an AI-based diagnostic or imaging device that would typically involve MRMC studies or AI assistance for human readers.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is a hip prosthesis, not an algorithm or AI.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • Non-clinical (Performance) Tests: Ground truth for these tests is based on engineering specifications, material properties, and established test standards (e.g., demonstrating mechanical compatibility and fatigue life under simulated physiological conditions).
    • Clinical Evaluation: The "ground truth" for the clinical evaluation is based on the outcomes data and findings reported in the systematic scientific literature review regarding the safety and effectiveness of the Corail Hip System for femoral neck fractures, by extension supporting the expanded indications for hemi-arthroplasty.

    8. The sample size for the training set

    Not applicable. This is a medical device for hip arthroplasty, not an AI or machine learning model that requires a training set.

    9. How the ground truth for the training set was established

    Not applicable. As above, there is no training set for this type of device submission.