510(k) Data Aggregation

    K Number
    K250721

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-08-20

    (163 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Predicate For
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The LOCATOR Angled Abutment is indicated for the attachment of full or partial, fixed and removable restorations retained by endosseous implants to restore masticatory function for the patient.

    Device Description

    The purpose of this submission is to expand the Indications for Use of the LOCATOR® Angled Abutment product line (K243272 & K233587) by adding compatibility of existing abutments with various new dental implant systems from Implant Direct and Biohorizons. Additionally, the submission expands the Indications for Use of the product line with a modified version of the predicate device shown to be compatible with the Implant Logistics Implant-One Series 300 and Series 400 Implant Systems. The LOCATOR Angled Abutment is designed and intended for the attachment of full or partial, fixed and removable, restorations retained by endosseous implants in the mandible or maxilla, as cleared to be used with LOCATOR FIXED (K213391) and LOCATOR Attachment Systems (K072878).

    The LOCATOR Angled Abutments are manufactured from titanium (Ti-6Al-4V) and are titanium nitride (TiN) coated in various abutment heights, identical to the predicate device. The LOCATOR Angled Abutment interfacing features are provided at a 15 degree angle to allow for angle correction, substantially equivalent to the predicate device of K233587 and K243272. The abutments will be used with the accessories of the LOCATOR Implant Attachment System (retention inserts, denture attachment housing, and ancillary processing parts) and LOCATOR FIXED Attachment System (fixed inserts, denture attachment housing) for the attachment of a restoration, identical to the predicate device.

    AI/ML Overview

    The provided document is an FDA 510(k) clearance letter for the LOCATOR® Angled Abutment, K250721. This document primarily focuses on demonstrating substantial equivalence to a predicate device and expanding indications for use, rather than detailing a study that proves the device meets specific performance acceptance criteria for a new clinical application.

    Therefore, much of the requested information regarding study design, sample sizes, expert involvement, and ground truth establishment (which are typical for AI/ML device clearances or those requiring extensive clinical performance data) is not present in this type of regulatory submission for a dental implant abutment.

    However, based on the information provided, I can construct a table for the acceptance criteria and reported "performance" in the context of this 510(k) submission, which is primarily a demonstration of mechanical compatibility and safety rather than a clinical efficacy study.

    Here's an interpretation based on the provided text:


    Overview of Device Performance and Acceptance Criteria (as per the 510(k) Submission)

    The LOCATOR® Angled Abutment (K250721) is a dental implant abutment. The "study" proving it meets acceptance criteria in this context is a series of non-clinical tests and engineering analyses demonstrating its compatibility with various dental implant systems and confirming its mechanical properties and biocompatibility are substantially equivalent to previously cleared devices. The acceptance criteria are implicitly met by showing conformance to established standards and similarity to predicate devices.

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategorySpecific Acceptance Criteria (Implicit)Reported Device Performance / Evidence Provided
    Material CompositionConformance to ASTM F136 for Ti-6Al-4V ELI (Titanium alloy) and presence of TiN coating.Manufactured from Ti-6Al-4V ELI (ASTM F136 compliant) with TiN coating, "identical to the predicate device."
    Mechanical Strength & Fatigue (Worst-Case)Withstand fatigue loading per ISO 14801:2016 for tallest abutment cuff height with smallest diameter OEM implant.Fatigue testing conducted per ISO 14801:2016 for worst-case scenarios. Implicitly, the device passed. For Implant Logistics, existing 510(k) (K173701, K102822) required ISO 14801 testing, and the current design "does not create a new worst case."
    BiocompatibilityConformance to ISO 10993-1 and ISO 10993-5 (cytotoxicity).Biocompatibility assessed per ISO 10993-1 and ISO 10993-5, leveraging prior testing (K072878, K233587). Implicitly, the device is biocompatible.
    Packaging & Shipping IntegrityPackaging and device remain undamaged after validation testing.Packaging and shipping validation testing completed; "worst case device and packaging were undamaged."
    Cleaning & Sterilization ValidationDevice can be effectively cleaned and sterilized, identical to predicate, without creating new worst-case.Cleaning and sterilization "identical to the predicate device," leveraging prior results (K233587, K243272). Engineering analysis established no new worst-case.
    MR Compatibility (Safety in MR Environment)Conformance to ASTM standards (F2052, F2213, F2182, F2119) and FDA guidance for MR safety (Force, Torque, Heating, Image Quality).MR compatibility testing conducted per specified ASTM standards and FDA guidance on Ti-6Al-4V components with similar features, leveraging prior results. Engineering analysis showed no new worst-case.
    Implant Compatibility (Functional)Proper fit and function with specified new implant systems.Critical features and tolerances verified functionally in OEM implants through "engineering analysis" and "cooperatively with the implant manufacturer (OEM)." The design for Implant Logistics systems was made "according to the manufacturer's specifications."

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size: Not explicitly stated as "sample size" in the conventional sense for a clinical trial. For physical testing (fatigue, packaging), standard engineering test specimen numbers would have been used, but these are not detailed. For material and biocompatibility, existing data was leveraged. Functional compatibility was primarily through engineering analysis.
    • Data Provenance: The data comes from in-vitro non-clinical testing and engineering analyses conducted by the manufacturer, Zest Anchors, LLC, or leveraged from previous submissions (K243272, K233587, K213391, K072878, K173701, K102822). The origin is the manufacturer's internal testing and regulatory submissions. The nature of these tests is "retrospective" in the sense that results from previous validated tests (e.g., K233587 for TiN coating, K072878 for biocompatibility) are being applied ("leveraged") to demonstrate equivalence for the current device, implying these tests were performed in the past.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications

    • Number of Experts: Not applicable. For this type of device (dental abutment) and submission (510(k) for expanded compatibility), "ground truth" is established through engineering specifications, material standards, and validated physical/mechanical testing protocols (e.g., ISO, ASTM). It does not involve human expert consensus on clinical images or patient outcomes.
    • Qualifications of Experts: N/A, as the "ground truth" is based on objective, standardized physical and material properties, confirmed by engineering analysis.

    4. Adjudication Method for the Test Set

    • Adjudication Method: Not applicable. This is not a study requiring human adjudication of results. Engineering and laboratory tests have objective pass/fail criteria or conformance to standards.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • MRMC Study Done? No. MRMC studies are typically for AI/ML devices where human readers interpret diagnostic images. This device is a physical dental implant component.
    • Effect Size of Human Readers Improvement: Not applicable.

    6. Standalone Performance Study (Algorithm Only)

    • Standalone Performance Study Done? No. This device is a physical medical device, not an algorithm.

    7. The Type of Ground Truth Used

    • Type of Ground Truth: The "ground truth" for this device's "performance" and "acceptance" is based on:
      • Engineering specifications and drawings: Ensuring physical compatibility (e.g., fit with implants).
      • International Standards: Conformance to mechanical testing standards (ISO 14801:2016 for fatigue), material standards (ASTM F136), and biocompatibility standards (ISO 10993 series).
      • Predicate device performance: Demonstrating that the subject device's design, materials, and performance characteristics are "identical" or "substantially equivalent" to previously cleared devices.

    8. The Sample Size for the Training Set

    • Sample Size for Training Set: Not applicable. This is not an AI/ML device that requires a training set.

    9. How the Ground Truth for the Training Set Was Established

    • How Ground Truth Established: Not applicable.
    Ask a Question

    Ask a specific question about this device

    K Number
    K222984

    Validate with FDA (Live)

    Date Cleared
    2022-12-29

    (92 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K213391, K033699, K142890

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The BioClean Implant Restorative System is designed to support fixed/detachable partial or full arch restorations on endosseous dental implants in the maxilla for the purpose of restoring masticatory function. It is used in fixed/detachable restorations that can be attached with a friction-based engagement system.

    All digitally designed copings for use with the BioClean Implant Restorative System are to BioClean Dental or a validated milling center for manufacture.

    The BioClean Implant Restorative System is compatible with the following:

    BioClean Implant Restorative System Compatibility
    Implant ComponentsConfigurations
    Bone Level Straumann® Multi-UnitAbutments NC/RCStraumann Multi-Unit Abutment OcclusalScrew4.6mm Platform Diameter, All GingivalHeights
    Device Description

    The BioClean Implant Restorative System provides rigid connection of partial and full arch restorations to endosseous dental implants in the mandible or maxilla.

    The BioClean Implant Restorative System consists of copings, denture housings, and retention inserts that are intended to allow for a fixed/detachable prosthesis to be connected to OEM multiunit abutments for stable attachment of the prosthesis to endosseous dental implants. All BioClean copings are made of titanium alloy and have the same coronal ridge retention design that attaches to the prosthesis component by a friction-based engagement system. The subject device coping connects to the OEM multi-unit abutment and is specific to each compatible abutment system and diameter.

    The subject device copings are offered with angulation from 0° to 9° in 0.5° increments and also in a patient specific version in which the dental laboratory technician designs the coping in CAD software and then sends the design to BioClean Dental or a validated milling center for fabrication from a coping blank. By use of a combination of pre-manufactured and patientspecific versions of the copings, a multi-unit prosthesis can be created in which the copings are parallel.

    AI/ML Overview

    The provided text is a 510(k) Summary for a dental device, the BioClean Implant Restorative System. It details the device's indications for use, technological characteristics, and a comparison to predicate devices to establish substantial equivalence. However, it does not contain information about acceptance criteria, the specific study design (e.g., sample sizes for training/test sets, data provenance), expert involvement, or statistical analysis of device performance against defined criteria, which would typically be found in a clinical study report or a more detailed performance evaluation.

    The document states that "Non-clinical testing data submitted to demonstrate substantial equivalence included:" and then lists several types of tests:

    • Sterilization validation
    • Biocompatibility testing
    • Mechanical testing (ISO 14801 for dynamic loading of dental implants)
    • Reverse engineering to verify OEM compatibility
    • Retention testing
    • Non-clinical worst-case MRI review

    While "Retention testing was conducted to ensure that retention is maintained throughout the expected use of the product. Retention strength of the subject devices was tested and compared to the retention strength of reference device K033699," this is the only mention of a quantitative comparison to a reference device's performance, but it does not provide acceptance criteria or the actual performance values.

    Therefore, I cannot fully answer your request based on the provided text. The document focuses on demonstrating substantial equivalence through non-clinical testing and comparison of fundamental device characteristics and indications for use, rather than presenting a performance study against explicit acceptance criteria with detailed statistical results.

    Here's what can be extracted and what is missing based on your prompts:


    1. A table of acceptance criteria and the reported device performance

    Cannot be fully provided from the text. The document states that "Retention testing was conducted to ensure that retention is maintained throughout the expected use of the product. Retention strength of the subject devices was tested and compared to the retention strength of reference device K033699." However, it does not explicitly define acceptance criteria (e.g., "retention strength must be X N or within Y% of predicate") nor does it report the specific measured retention strength values for either the subject device or the reference device.

    Acceptance CriteriaReported Device Performance
    (Not explicitly stated for quantifiable metrics like retention strength)(Specific values not reported for quantifiable metrics like retention strength)
    Retention is maintained throughout expected use.Retention strength tested and compared to reference device K033699. (Specific results not given).
    OEM compatibility verified.Key dimensions measured from OEM implants, abutments and screws; dimensions and tolerances established for corresponding BioClean copings to ensure compatibility.
    Biocompatibility compliant.Testing according to ISO 10993-5 and ISO 10993-12. (Implicitly met, no specific data presented).
    Sterilization validated.Validation according to ISO 17665-1 and ISO 17665-2. (Implicitly met, no specific data presented).
    Mechanical testing compliant with standards.Testing according to ISO 14801. (Implicitly met, no specific data presented).

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    Not available in the text. The document describes non-clinical laboratory testing, but does not specify the sample size for any of the tests (e.g., number of devices tested for retention, number of samples for biocompatibility). Data provenance (country of origin, retrospective/prospective) is also not mentioned, but given it's non-clinical lab testing, it's typically done in a controlled environment and not tied to patient data provenance in the same way clinical studies are.


    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable/Not available. This document describes non-clinical engineering and biological performance testing of a physical medical device (dental implant components). Ground truth as established by experts (e.g., radiologists interpreting images) is not relevant to the types of tests described here (mechanical, biocompatibility, sterilization validation).


    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable/Not available. Adjudication methods are typically used in clinical studies involving human interpretation or subjective assessments, often for establishing ground truth from multiple readers. This is not relevant to the non-clinical lab testing described.


    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This device is a physical dental implant restorative system, not an AI-powered diagnostic or assistive tool for human readers. Therefore, an MRMC study is not relevant.


    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is a physical medical device, not an algorithm.


    7. The type of ground truth used (expert concensus, pathology, outcomes data, etc)

    Not applicable/Implicit in testing standards. For mechanical testing (ISO 14801), the "ground truth" is defined by the physical properties and performance metrics specified in the standard. For biocompatibility (ISO 10993), the "ground truth" for safety is determined by the absence of cytotoxic effects or other adverse biological responses as per the standardized test protocols. For sterilization, it's documented sterility assurance levels. This is not "ground truth" in the sense of clinical diagnostic accuracy.


    8. The sample size for the training set

    Not applicable. This device is hardware, not a machine learning algorithm that requires a training set. The term "training set" would apply if this were an AI or software device.


    9. How the ground truth for the training set was established

    Not applicable. As above, no training set is involved for this hardware device.