    Intended Use

    The Suture Anchors - HTA Headless Titanium Anchor and ZIP Anchors are indicated to be used for suture or tissue fixation in the elbow, shoulder, hand, wrist, foot, ankle, knee, and hip. Specific indications are listed below:

    Elbow: Biceps Tendon Reattachment, Ulnar or Radial Collateral Ligament Reconstruction

    Shoulder: Rotator Cuff Repair, Bankart Repair, Biceps Tenodesis, Acromio-Clavicular Separation Repair, Deltoid Repair, Capsular Shift or Capsulolabral Reconstruction

    Hand Wrist: Scapholunate Ligament Reconstruction of collateral ligaments, Repair of Flexor and Extensor Tendons at the PIP, DIP and MCP joints for all digits, digital tendon transfers, Carpal Ligament Reconstruction and Carpometacarpal joint arthroplasty (basal thumb joint arthroplasty)

    Foot/Ankle: Lateral Stabilization, Medial Stabilization, Achilles Tendon Repair, Metatarsal Ligament Repair, Hallux Valgus reconstruction, digital tendon transfers, Mid-foot reconstruction

    Knee: Medial Collateral Ligament Repair, Lateral Ligament Repair, Patellar Tendon Repair, Posterior Oblique Ligament Repair, Iliotibial Band Tenodesis

    Hip: Capsular repair, acetabular labral repair.

    Device Description

    The Suture Anchors, manufactured by GM dos Reis Indústria e Comércio Ltda, are anchor-type implants, and are composed of two groups of anchors, manufactured in Titanium Alloy (ASTM F136) and Ultra High Molecular Weight Polyethylene – UHMWPE (which are called ZIP Anchor), that is the same raw material of the suture. The anchors are made available preloaded in a disposable inserter device, composed of a metal rod and a polymeric cable. The implant and disposable inserter devices are unique products and cannot be sold separately.

    Implants of the Suture Anchors - GM Reis are classified as surgically invasive, non-absorbable, and non-active implantable medical devices. In addition, the implants, as well as, the inserter device, are for single-use and sold in sterile form - supplied as a sterile kit for ethylene oxide (ETO) according to ISO 11135 - "Preview Sterilization of health-care products -- Ethylene oxide -- Requirements for the development, validation and routine control of a sterilization process for medical devices".

    The Suture Anchors - GM Reis is composed of two different groups of anchors:

    • HTA – Headless Titanium Anchor.
      • Anchor Diameters: ø1,7 mm; ø2,2 mm; ø2,7 mm; ø3,5 mm and ø5,0 mm
    • -ZIP Anchor.
      • Ø0.9mm; Ø1.2mm; Ø1.5mm; Ø1.8mm; Ø1.9mm; Ø2.6mm.
    AI/ML Overview

    This document is a 510(k) Premarket Notification from the FDA regarding "Suture Anchors - HTA Headless Titanium Anchor and ZIP Anchors." It details the device, its intended use, and a comparison to predicate devices, but it does not contain any information about acceptance criteria or a study proving the device meets those criteria for an AI/algorithmic device.

    The document discusses non-clinical performance data for the suture anchors themselves (insertion torque, pullout strength, MRI compatibility) to demonstrate substantial equivalence to predicate devices, but this is for a physical medical device, not a software or AI-driven diagnostic or therapeutic tool.

    Therefore, I cannot provide the requested information based on the provided text. The prompt asks for details about a study proving an AI/algorithmic device meets acceptance criteria, which is not what this FDA document is about.

    Ask a Question

    Ask a specific question about this device

    K Number
    K183395

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2019-04-17

    (131 days)

    Product Code
    Regulation Number
    888.3040
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K172612

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Arthrex 2.5 mm Tenodesis Screw is intended to be used for suture or tissue fixation in the foot, ankle, knee, hand, wrist, elbow, and shoulder. Specific indications are listed below:
    Elbow: Biceps Tendon Reattachment, Ulnar or Radial Collateral Ligament Reconstruction
    Shoulder: Rotator Cuff Repair, Bankart Repair, SLAP Lesion Repair, Biceps Tenodesis, Acromio-Clavicular Separation Repair, Deltoid Repair, Capsular Shift or Capsulolabral Reconstruction
    Hand/Wrist: Scapholunate Ligament Reconstruction, Carpal Ligament Reconstruction, Repair/Reconstruction of collateral ligaments, Repair of Flexor and Extensor Tendons at the PIP, DIP and MCP joints for all digits, digital tendon transfers
    Foot/Ankle: Lateral Stabilization, Medial Stabilization, Achilles Tendon Repair, Metatarsal Ligament Repair, Hallux Valgus reconstruction, digital tendon transfers, Mid-foot reconstruction
    Knee: Medial Collateral Ligament Repair, Lateral Collateral Ligament Repair, Patellar Tendon Repair, Posterior Oblique Ligament Repair, Iliotibial Band Tenodesis

    Device Description

    The Arthrex 2.5 mm Tenodesis Screw is a fully threaded, cannulated screw with a rounded head. The screw will be offered in a 2.5 mm diameter and 6 mm length. The screw is manufactured from Polyetheretherketone (PEEK). The screw is sold as sterile, single-use.

    AI/ML Overview

    The provided text describes the regulatory filing for a medical device, the Arthrex 2.5 mm Tenodesis Screw, and its substantial equivalence to predicate devices. It does not contain information about an AI/ML-based device, nor does it detail acceptance criteria or studies related to AI/ML performance.

    Therefore, I cannot provide the requested information regarding:

    • A table of acceptance criteria and reported device performance for an AI/ML device.
    • Sample sizes, data provenance, number/qualifications of experts, or adjudication methods for an AI/ML device test set.
    • Whether a multi-reader multi-case (MRMC) comparative effectiveness study was done for an AI/ML device.
    • Whether standalone (algorithm-only) performance was done for an AI/ML device.
    • The type of ground truth used for an AI/ML device.
    • Sample size for an AI/ML device training set.
    • How ground truth for an AI/ML device training set was established.

    The document discusses performance data for the Arthrex 2.5 mm Tenodesis Screw in terms of mechanical testing (pull-out and failure torque/insertion torque), sterilization (ethylene oxide with a SAL of 10⁻⁶), shelf life (5 years for PEEK material), and biocompatibility testing (Bacterial Endotoxins Test, Cytotoxicity, Sensitization, Irritation, Genotoxicity, Systemic Toxicity, Subchronic/Subacute Toxicity, Implantation, and Material Characterization). The acceptance criteria for these tests are implicitly that the new device performs "statistically equivalent" to the predicate device for mechanical properties and meets established standards (e.g., ISO 10993-1:2018 for biocompatibility, ANSI/AAMI ST72:2011/(R)2016 for sterility).