Search Results
Found 231 results
510(k) Data Aggregation
(180 days)
Ask a specific question about this device
(132 days)
The Neodent Implant System is intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices, such as artificial teeth, to restore chewing function. The Direct Screw to MUA may be used with single-stage or two-stage procedures, for screw-retained multi-unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading.
The digitally designed personalized copings to be used with the Direct Connection Screw to Multi-Unit Abutment are to be:
- Sent to Straumann for manufacture at a validated milling center, or
- Manufactured following the Neodent InLab Validated Workflow.
The Neodent InLab Validated Workflow is indicated for the design and fabrication of screw-retained multi-unit restorations for the restoration of partially or fully edentulous mandibles and maxillae. The system integrates multiple components: scan files from intra-oral scanners, CAD software, CAM software, milling machines and associated tooling and accessories.
The purpose of this premarket notification is to obtain market clearance to expand the options for fabrication of digitally designed personalized copings for use with the Neodent Direct Screw to multiunit abutment (MUA) from a "validated milling center" (cleared in K242686), to include a digital dentistry workflow.
The Neodent InLab Validated Workflow is integrated by multiple components of digital dentistry workflow: scan files from intra-oral scanners, CAD software, CAM software, milling machines and associated tooling and accessories. This new workflow employs optical impression files that document the topographical characteristics of teeth and traditional dental impressions, which are transferred to the CAD software (CARES® Visual, 3Shape or Exocad) and allows the design of the desired restorations, according to the Direct Screw to MUA dimensions. The CAM software converts the digital restoration design into the tooling and tool path commands needed to fabricate the restoration by the indicated milling equipments (Roland and Zirkonzahn).
N/A
Ask a specific question about this device
(93 days)
The Neosoma software uses an artificial intelligence algorithm (i.e., deep learning neural networks) to contour (segment) known or previously diagnosed brain tumors on MRI images for qualified and trained medical professionals.
The technology is meant for informational purposes only and not intended to replace the clinician's current standard practice of manual contouring. The software does not alter the original MRI image, nor is it intended to be used to detect tumors for diagnosis. The software is intended to be used on adult patients only.
When using the Neosoma software in a radiation oncology planning workflow, or other clinical workflows, it is intended for generating Gross Tumor Volume (GTV) contours. For all clinical workflows, medical professionals must finalize (confirm or modify) the contours generated by the Neosoma software, as necessary, using an external platform available at the facility that supports DICOM viewing/editing functions, such as image visualization software and treatment planning system.
Neosoma Brain Mets is a Software as a Medical Device (SaMD) that is designed specifically for the semi-automatic segmentation of previously diagnosed brain metastases. This functionality is applicable to the T1 post-contrast sequence, which is routinely obtained in clinical practice through brain Magnetic Resonance Imaging (MRI).
It is important to note that the standard criterion for diagnosing brain metastasis includes the presence of a known primary cancer that has been identified as having metastasized to the brain. Accordingly, Neosoma Brain Mets is not intended for use with images representing other types of brain lesions.
Furthermore, Neosoma Brain Mets is specifically designed for use in adult patient populations (age 22 and older). As such, its usage should be confined to this demographic to ensure compliance with its intended use parameters and to maximize the accuracy and relevance of its results.
The analysis performed by the AI includes semi-automatic segmentation of the metastasis based on pixel signal intensity. The volumes are calculated using non-machine-learning post-processing from the AI segmentation output. For this segmentation, the software requires one MRI sequence (T1 post-contrast) as input, and it outputs post-processed images that contain color-coded segmentations, as well as volumetric measurements.
Here's an analysis of the acceptance criteria and study details for the Neosoma Brain Mets device, based on the provided FDA 510(k) clearance letter:
Neosoma Brain Mets - Acceptance Criteria and Study Details
1. Acceptance Criteria and Reported Device Performance
| Metric | Acceptance Criteria | Reported Device Performance |
|---|---|---|
| Sensitivity | ≥ 0.85 | 0.90 (95% CI: 0.87 - 0.94) |
| False Positive Rate | ≤ 5 false positive lesions per MRI | 0.57 lesions per MRI (95% CI: 0.35 - 0.80) |
| DSC (Dice Similarity Coefficient) | ≥ 0.70 | 0.86 (95% CI: 0.83 - 0.89) |
| HD95 (95th percentile Hausdorff Distance) | ≤ 2.94 mm | 1.78 mm (95% CI: 1.02 - 2.54) |
| MSD (Mean Surface Distance) | ≤ 0.66 mm | 0.36 mm (95% CI: 0.16 - 0.56) |
2. Test Set Sample Size and Data Provenance
- Sample Size for Test Set: 70 subjects, each with one MRI (total of 70 MRIs).
- Data Provenance: Retrospective, multicenter study. Acquired from medical sites inside and outside of the US that were not included in the training dataset to ensure device generalizability. The data involved standard-of-care MRI protocols on Canon, GE, Siemens, and Toshiba scanners at both 1.5T and 3.0T.
- Patient Demographics in Test Set: Age range of 28 to 84, covering a diverse group of ethnic backgrounds. The distribution of primary cancers was consistent with the known epidemiology of brain metastases. A subgroup analysis demonstrated consistent device performance across various factors including site, imaging manufacturer, field strength, patient race and ethnicity, age, gender, primary cancer, and site geography.
3. Number of Experts and Qualifications for Ground Truth
- Number of Experts: Three.
- Qualifications of Experts: US board-certified neuroradiologists with expertise in measuring brain metastases.
4. Adjudication Method for the Test Set
The document explicitly states that the reference standard (ground truth) was established using three US board-certified neuroradiologists. However, it does not specify the adjudication method used (e.g., 2+1, 3+1, majority vote, or consensus). It simply states that the "reference standard (ground truth) was established using" these three experts.
5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study
No MRMC comparative effectiveness study involving human readers with and without AI assistance is described in the provided text. The study focuses on the standalone performance of the AI algorithm compared to an expert-established ground truth.
6. Standalone Performance (Algorithm Only)
Yes, a standalone (algorithm only, without human-in-the-loop performance) study was done. The report describes the clinical performance of the "Neosoma Brain Mets" device (the AI algorithm) against a reference standard established by experts. The performance metrics (Sensitivity, False Positive Rate, DSC, HD95, MSD) are all measures of the algorithm's direct output compared to the ground truth.
7. Type of Ground Truth Used
The ground truth used was expert consensus (or interpretation by multiple experts). It was established by three US board-certified neuroradiologists.
8. Sample Size for the Training Set
The document states that the test dataset was acquired from medical sites that were not included in the training dataset. However, it does not specify the sample size for the training set.
9. How the Ground Truth for the Training Set Was Established
The document does not provide information on how the ground truth for the training set was established. It only describes the establishment of the ground truth for the test set.
Ask a specific question about this device
(200 days)
Zirconia Implants:
The Neodent Implant System is intended to be surgically placed in the bone of upper or lower jaw to provide support for prosthetic devices, such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage surgical procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with physiological occlusion loading. Multiple teeth applications can be rigidly splinted. The implants with length of 5 mm (short implants) may be used only with two-stage surgical procedures. The recommended healing time before loading is between 10 to 12 weeks.
Zi Transmucosal Cover Screw and Healing:
The Neodent Implant System is intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices, such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage surgical procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with physiological occlusal loading. Multiple teeth applications can be rigidly splinted.
Zi Transmucosal Provisional Coping:
The Neodent Implant System is intended for surgical procedures in maxilla or mandible, providing support for prosthetic devices such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single- or multi-unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading.
Zi Transmucosal Abutment Replacement Screw:
The Neodent Implant System is intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices, such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading.
Zi Transmucosal Universal Base:
The Universal Ceramic Base Zi Transmucosal 5.0 is an abutment placed over Neodent Zi Transmucosal 5.0 Ceramic Implant System in order to provide support for custom-made prosthetic restorations, such as copings or crowns. It may be used for cement or screw-retained single unit restorations. All digitally designed copings and/or crowns to be used with the Neodent Zirconia Base Abutment System are intended to be sent to Straumann for manufacture at a validated milling center.
Zirconia Base for Bridge:
The Zirconia Base for Bridge is an abutment placed over Neodent Zirconia Implants in order to provide support for custom-made prosthetic restorations. It may be used for cement or screw-retained multi-unit restorations. All digitally designed copings and/or crowns to be used with the Neodent Zirconia Base Abutment System are intended to be sent to Straumann for manufacture at a validated milling center.
Zirconia Base C:
The Zirconia Base C is an abutment placed over Neodent Zirconia Implants in order to provide support for customized prosthetic restorations, such as copings or crowns. It may be used for single-unit restorations that are screw- or cement-retained in esthetic areas over implants installed in the maxilla or mandible. All copings and/or crowns digitally designed for use with the Titanium Base C are to be designed using Sirona inLab software or Sirona CEREC Software and manufactured using a Sirona CEREC or inLab MC X or MC XL milling unit.
This premarket notification includes new ceramic devices into Neodent Implant System, which are compatible with Zirconia Implant System. The Zirconia Implants and Abutments proposed on this submission are similar to devices already cleared in previous submissions of Neodent Implant System – Zirconia Implant System, according to predicate devices described above. This submission intends to expand the portfolio with new solutions and diameter, in order to provide more treatment options to the customers.
The Zirconia Implants are manufactured in Zirconia Y-TZP and are available in Bone Level (BL) or Tissue Level (TL or Transmucosal) configurations. The Zirconia Implants (BL) are available in a diameter of 5.0 mm and lengths in a range of 8 to 13 mm. The Zi Transmucosal Implants (TL) are available in a diameter of 5.0 mm and lengths in a range of 5 to 11.5 mm.
The Zi Transmucosal Healing and Cover Screw are temporary abutments manufactured in PEEK and used during the healing phase. They are compatible with the Zi Transmucosal Implants Ø5.0. The Zi Transmucosal Healing Abutment is available in the heights of 2 and 3.5mm.
The Zi Transmucosal Provisional Coping is a temporary abutment made of polycarbonate (PC) and has a double function: used for molding procedures or production of provisional restoration.
The Zi Transmucosal Abutment Replacement Screw is a prosthetic component manufactured in titanium alloy and used to fix the fix the Zi Transmucosal Base to the Zi Transmucosal Implant.
The Zi Transmucosal Universal Base is a two-piece abutment of base and top-half prosthetic structure to provide support for customized single-unit restorations over Zi Transmucosal Implant (TL). The base is manufactured in Zirconia Y-ZTP and used with a patient-specific top-half prosthetic structure. The two-piece abutment has a cementable portion of 4mm and is available with gingival heights of 0.3, 1.0 and 1.5 mm. The top-half prosthetic structure to be used with Zi Transmucosal Universal Base must be designed and milled in a Straumann Validated Milling center, using the following restoration materials and dimensions:
Material: IPS e.max CAD HT, Associated Material 510(k): K132209, Minimum wall thickness: 0.9 mm, Maximum angulation: 30°
Material: IPS e.max CAD LT, Associated Material 510(k): K132209, Minimum wall thickness: 0.9 mm
Material: N!ce, Associated Material 510(k): K171773, Minimum wall thickness: 1.0 mm
Material: IVOCLAR Multilink cement, Associated Material 510(k): K130436, Minimum wall thickness: N/A
Material: Zirconia N!ce® LT, Associated Material 510(k): K222836, Minimum wall thickness: 0.4 mm
Material: Zirconia N!ce® HT, Associated Material 510(k): K222836, Minimum wall thickness: 0.4 mm
Material: Zirconia N!ce® XT, Associated Material 510(k): K222836, Minimum wall thickness: 0.4 mm
Material: PMMA N!ce, Associated Material 510(k): K071548, Minimum wall thickness: 0.7 mm
Material: Panavia—Kuraray Cement, Associated Material 510(k): K150704, Minimum wall thickness: N/A, Maximum angulation: N/A
The Zi Base for Bridge is a two-piece abutment of base and top-half prosthetic structure to provide support for customized multi-unit restorations over Zirconia Implants (BL). The base is manufactured in Zirconia Y-ZTP and used with a patient-specific top-half prosthetic structure. The two-piece abutment has a cementable portion of 4mm and is available with gingival heights of 1.5, 2.5 and 3.5 mm. The top-half prosthetic structure to be used with Zi Base for Bridge must be designed and milled in a Straumann Validated Milling center, using the following restoration materials and dimensions:
Material: Zirconia N!ce® LT, Associated Material 510(k): K222836, Minimum wall thickness: 0.4 mm, Maximum angulation: 30°
Material: Zirconia N!ce® HT, Associated Material 510(k): K222836, Minimum wall thickness: 0.4 mm
Material: Zirconia N!ce® XT, Associated Material 510(k): K222836, Minimum wall thickness: 0.4 mm
Material: PMMA N!ce, Associated Material 510(k): K071548, Minimum wall thickness: 0.7 mm
Material: Panavia—Kuraray Cement, Associated Material 510(k): K150704, Minimum wall thickness: N/A, Maximum angulation: N/A
The Zi Base C is a two-piece abutment of base and top-half prosthetic structure to provide support for customized single-unit restorations over Zirconia Implants (BL). The base is manufactured in Zirconia Y-ZTP and used with a patient-specific top-half prosthetic structure. The two-piece abutment has a cementable portion of 4mm and is available with gingival heights of 1.5, 2.5, 3.5 and 4.5 mm. The top-half prosthetic structure to be used with Zi Base C must be designed and milled in a Sirona InLab Validated Workflow, using the following restoration materials and dimensions:
Material: IPS e.max CAD, Associated Material 510(k): K132209, Minimum wall thickness: 0.9 mm, Maximum angulation: 20°
Material: IVOCLAR Multilink cement, Associated Material 510(k): K130436, Minimum wall thickness: N/A, Maximum angulation: N/A
All these abutments have an internal connection with the implants (ZiLock) and the prosthetic platform is identical for all subject devices described in this submission. They are intended for single use and provided sterile via Ethylene Oxide method, along with undergoing moist heat sterilization after end-user customization.
The provided FDA 510(k) clearance letter and its associated summary for the Neodent Implant System - Zirconia Implant System contain extensive information about the device, its intended use, and comparisons to predicate devices. However, it does not include specific acceptance criteria with numerical thresholds directly stated within the tables, nor does it detail a study that directly proves the device meets such criteria in terms of performance metrics like sensitivity, specificity, or image quality assessments.
Instead, the submission focuses on demonstrating substantial equivalence to predicate devices through various tests, implying that if the new device performs similarly to or better than previously cleared devices, it meets the necessary standards. The performance testing section describes the types of tests conducted (e.g., dynamic fatigue, torsion, insertion, pull-out, and software validation), but it does not present clear quantitative acceptance criteria or the specific performance results in a comparative table format.
Therefore, many of the requested fields cannot be directly extracted from the provided text as they pertain more to the performance evaluation of AI/software in interpreting medical images, which is not the primary focus of this dental implant submission.
Here's an attempt to answer the questions based on the available information, noting where information is not explicitly provided in the document:
Acceptance Criteria and Device Performance Study for Neodent Implant System - Zirconia Implant System
The FDA 510(k) summary for the Neodent Implant System - Zirconia Implant System focuses on demonstrating substantial equivalence to predicate devices through a combination of bench testing, software validation, MRI compatibility, biocompatibility, and sterilization validation. It does not present specific quantitative acceptance criteria or performance metrics directly from a comparative study in the way one might expect for an AI/software-based medical device (e.g., sensitivity, specificity thresholds). Instead, the "acceptance criteria" are implicitly met by demonstrating that the proposed devices perform at a level substantially equivalent to legally marketed predicate devices under standardized testing conditions.
1. A table of acceptance criteria and the reported device performance
As mentioned, explicit numerical acceptance criteria and reported device performance in a comparative table (e.g., for diagnostic accuracy) are not provided in this 510(k) summary. The summary indicates that tests were conducted according to relevant ISO standards and FDA guidance, and the results demonstrated that the subject devices exhibit a level of performance substantial equivalent to the predicate and reference devices.
Below is a conceptual table based on the types of tests mentioned, noting that specific numerical acceptance criteria and performance data are not detailed in the provided text.
| Acceptance Criteria Category (Implicit) | Standard/Guidance | Reported Device Performance (Summary) |
|---|---|---|
| Dynamic Fatigue Strength | ISO 14801, FDA Guidance (Class II Special Controls) | Demonstrated a level of performance substantial equivalent to predicate and reference devices in identical conditions. |
| Torsion Strength | Not specified | Adequate torsion strength in accordance with recommended IFU installation torque. |
| Insertion Torque | Not specified | Evaluated insertion torque in sawbones material (Bone type I, II, III, IV). (Specific values not given). |
| Implant Surface Area & Pull-Out Strength | Not specified | Greater surface area compared to reference devices; higher resistance values in Pull Out Test. |
| Software Validation (Sirona Digital Workflow) | Not specified | Accuracy requirement was met; critical design parameters (min wall thickness, max angulation) respected and monitored. |
| MRI Compatibility | K182620, FDA Guidance | MR conditional labeling from K182620 is applicable; safe for scanning under previously established parameters. |
| Biocompatibility | ISO 10993-1, ISO 10993-18, ISO 10993-5, FDA Guidance | Subject devices are equivalent in material and manufacturing processes to predicates; no new issues raised; no additional testing required. |
| Sterilization Validation (Ethylene Oxide) | ISO 11135:2014 | Validated to a Sterility Assurance Level (SAL) of 1x10⁻⁶; residuals below max allowable limits per ISO 10993-7. |
| Sterilization Validation (Moist Heat) | ISO 17665-1 | Validated using parameters described in IFU. |
| Endotoxin Test | ANSI/AAMI ST72:2011, ISO 11737-3, US Pharmacopeia chapter 85 | Results <0.05 EU/device. |
| Shelf Life | Not specified | Determined to be 5 years; packaging identical to predicates. |
2. Sample size used for the test set and the data provenance
The document details various bench tests (dynamic fatigue, torsion, insertion, pull-out) and validation studies (software, MRI, biocompatibility, sterilization, endotoxin, shelf-life). However, specific numerical sample sizes ("n=") for these individual tests are not provided in the summary. For example, for dynamic fatigue testing, it states "the results demonstrated that...". It doesn't specify how many implants or setups were tested.
- Data Provenance (Country of Origin): The submitter is JJGC Indústria e Comércio de Materiais Dentários S.A. (dba Neodent) based in Curitiba, Paraná, Brazil. The tests are generally conducted to international ISO standards and FDA guidance, but the location where the tests were performed is not explicitly stated for each test beyond the company's Brazilian location.
- Retrospective or Prospective: Not applicable in the context of bench testing and validation studies as described. These are laboratory-based tests rather than clinical studies on patient data.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts
This information is not applicable and not provided in the context of this 510(k) submission. The device is a dental implant system (hardware), not an AI/software device that interprets medical images requiring expert-established ground truth for a test set. The validation processes involve standardized engineering and biological tests as opposed to expert review of clinical cases.
4. Adjudication method (e.g. 2+1, 3+1, none) for the test set
This information is not applicable and not provided. As explained above, the submission pertains to a hardware device, not an AI/software system requiring human adjudication for ground truth establishment.
5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
This information is not applicable and not provided. This type of study is relevant for AI-assisted diagnostic tools, not for dental implant hardware.
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
This information is not applicable and not provided. This concept is specific to AI/software performance, not a physical dental implant system. The "software validation" mentioned is for the compatibility of milling units (CAD/CAM workflow), ensuring design parameters are respected, not for an AI algorithm interpreting dental images.
7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)
For the bench tests, the "ground truth" is defined by compliance with established engineering standards (e.g., ISO 14801 for dynamic fatigue) and specifications (e.g., material properties, dimensions). For biological safety, it's compliance with ISO 10993. For the CAD/CAM software, it's the accurate adherence to design parameters. This isn't "ground truth" in the diagnostic sense, but rather adherence to predefined engineering and biocompatibility specifications.
- Clinical Literature Review: A clinical literature review was conducted to support the safety of Zi Transmucosal Implant less than 7mm of length, referencing animal studies and histomorphometry evaluation. This aligns with outcomes data or pathological/histological evidence from preclinical studies, suggesting "similar osseointegration outcomes" and "ability to promote bone formation around them in a manner equivalent to titanium implants."
8. The sample size for the training set
This information is not applicable and not provided. This concept is specific to machine learning/AI models, which are not the subject of this 510(k) submission.
9. How the ground truth for the training set was established
This information is not applicable and not provided. As above, this is relevant for AI/ML training data, not for a physical dental implant system.
Ask a specific question about this device
(88 days)
Custom Abutment AS Ti:
The Custom Abutment with Angled Screw Channel is a customized prosthetic abutment, manufactured in titanium alloy, placed onto dental implants to provide support for customized prosthetic restorations. All abutments are only intended to be digitally designed and manufactured using specifics CAD/CAM software according to digital dentistry workflow. Custom Abutments with Angled Screw Channel are indicated for screw-retained single restorations or cemented retained single or multiple restorations. All digitally designed abutments for use with the Custom Abutment Ti with Angled Screw Channel are intended to be sent to Straumann for manufacturing at a validated milling center.
ASC Screw:
The Neodent Implant System is intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices, such as artificial teeth, to restore chewing function. It may be used with single-stage or two-stage procedures, for single or multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading.
This premarket notification includes new digital abutments to the Neodent Implant System (GM, NGM and HS prosthetic interfaces). The abutments proposed on this submission are identical to devices already cleared in previous submissions of Neodent Implant System, according to predicate devices described above, being the only difference between them the introduction of a new angled channel solution. This submission intends to expand the portfolio of Neodent Implant System. The Custom Abutments AS Ti are composed of a unique body with two different regions: the upper region, which is the customizable portion, and the end region presents the prosthetic interface that fits with the implant, which does not allow customization. They must be sent to a Straumann Validated Milling
This document describes the Neodent Implant System - Custom Abutments and its FDA 510(k) clearance (K250614). The information provided is primarily focused on demonstrating substantial equivalence to a predicate device, rather than detailed performance study results with specific acceptance criteria and performance metrics for a novel AI/software device.
Based on the provided text, the device is a physical medical device (dental implant abutment) and not an AI/software device. Therefore, the questions related to AI/software performance studies, such as sample size for test sets, expert adjudication, MRMC studies, standalone algorithm performance, and training set details, are not applicable to this submission.
The "Performance Testing" section primarily describes bench testing (dynamic fatigue and torsion tests), biocompatibility testing, and sterilization validation, which are standard for physical medical devices.
Here's a breakdown of the available information:
1. Table of Acceptance Criteria and Reported Device Performance
The document does not explicitly state "acceptance criteria" in the format typically seen for performance metrics of a diagnostic device. Instead, it describes general compliance with standards and the determination of "not a new worst case" for dynamic fatigue.
| Acceptance Criterion (Inferred from testing) | Reported Device Performance |
|---|---|
| Dynamic Fatigue Testing (ISO 14801 compliant, FDA Guidance) | Subject devices are not a new worst case compared to predicate devices. (No specific values reported in this document). |
| Torsion Testing | Results prove adequate torsion strength in accordance with recommended installation torque. (No specific values reported). |
| Biocompatibility (ISO 10993-1, ISO 10993-5, ISO 10993-18 compliant) | Subject devices are equivalent in material and manufacturing processes to predicate devices; no new issues raised, no additional testing required. |
| Sterilization Validation (ISO 17665-1 compliant) | Sterilization method (moist heat, SAL of 1x10-6) was validated and is identical to predicate devices. |
| MRI Compatibility | MR conditional labeling from predicate (K182620) is applicable to subject devices. |
2. Sample Size Used for the Test Set and Data Provenance
- Sample Size for Bench Testing (Dynamic Fatigue and Torsion): Not
explicitly stated. The document mentions "a worst case analysis determined that the subject devices are not a new worst case compared to those devices tested for the primary predicate." This implies that testing was performed on a sufficient number of samples to make this determination, likely following the requirements of ISO 14801. - Data Provenance: Not explicitly stated, but these are typically laboratory-based bench tests performed by the manufacturer or a contracted testing facility.
3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications
- Not Applicable. This is a physical device, and the testing involves objective measurements (e.g., force, torque, material properties) rather than expert interpretation of data for ground truth establishment.
4. Adjudication Method for the Test Set
- Not Applicable. As above, the tests are objective physical measurements.
5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study Was Done
- Not Applicable. This is a physical device, not an AI-assisted diagnostic or decision support system.
6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) Was Done
- Not Applicable. This is a physical device. While it involves digital design using CAD/CAM software, the 'device' itself is the physical abutment, and its performance is evaluated through physical and material tests, not software algorithm performance.
7. The Type of Ground Truth Used
- Physical/Material Standards and Engineering Specifications. For dynamic fatigue and torsion tests, the "ground truth" or acceptance criteria are derived from established engineering principles, material properties (ASTM F136 for titanium alloy), and international standards (ISO 14801). For biocompatibility, it's compliance with ISO 10993 series.
8. The Sample Size for the Training Set
- Not Applicable. This is a physical device; there is no "training set" in the context of machine learning or AI models.
9. How the Ground Truth for the Training Set Was Established
- Not Applicable. As above, no training set for an AI/ML model for this physical device.
Ask a specific question about this device
(56 days)
The Fibers are indicated for use in general surgical applications for incision, vaporization, ablation, hemostasis or coagulation of soft tissue. It is also indicated for use in open or closed endoscopic applications where incision, excision, tissue dissection, excision of external tumors and lesions, complete or partial resection of internal organs, tumors or lesions, tissue vaporization, hemostasis and or coagulation may be indicated. The neoLaser Laser Surgery Fibers have a wavelength range of 450 nm to 2100 nm, can be used in contact mode and are indicated for use in general surgery, urology, gastroenterology, dermatology, vascular surgery, neurosurgery, plastic surgery, ENT and endovenous occlusion of the greater saphenous vein in the patient with superficial vein reflux and laser assisted lipolysis with a cleared compatible laser marketed for the mentioned intended uses and using an SMA 905 connector.
The neoLaser Laser Surgery Fibers are sterile, single use, laser delivery devices intended for medical applications in various fields of laser surgery. They are intended to deliver energy to soft tissue in contact and non-contact mode during various surgical applications, including via endoscopes and cytoscopes. The fibers are designed to transmit energy from the laser system to the treatment site, as well as to transmit a low power laser aiming beam to assist in the visibilty of the target tissue.
The provided text is a 510(k) summary for the neoLaser Laser Surgery Fibers. It describes a medical device and its substantial equivalence to a predicate device, BeaMed Laser Surgery Fibers (K232769). This type of submission relies on demonstrating that the new device is as safe and effective as a legally marketed predicate device, rather than requiring extensive clinical trials to prove efficacy from scratch.
Therefore, the document does not outline acceptance criteria or a study proving the device meets those criteria in the context of an AI/algorithm-based medical device performance study. Instead, it focuses on demonstrating equivalence through comparison of technical characteristics and performance bench testing.
Here's why the requested information cannot be extracted from this document:
- The device is a physical medical instrument (laser surgery fibers), not an AI/algorithm-based device. The questions about MRMC studies, human reader improvement with AI, standalone algorithm performance, and ground truth establishment for training/test sets are relevant to AI/ML medical devices, not simple surgical tools.
- The 510(k) pathway for this device is based on "substantial equivalence" to a predicate device. This means the manufacturer proves the new device is as safe and effective as an already cleared device through comparison of specifications, materials, and bench testing, not through new clinical performance studies against defined acceptance criteria for a novel technology.
- The document explicitly states: "Animal or clinical studies: None." This confirms that performance studies in the way you've outlined for AI/ML models (with test sets, ground truth, expert readers, etc.) were not conducted or required for this 510(k) submission.
However, I can extract information regarding the device's characteristics and the types of "performance" assessments that were deemed sufficient for this 510(k) clearance, even though they don't align with the typical AI/ML study framework you've described.
Based on the provided document, here's an attempt to address the prompt's points, reinterpreting them for a physical medical device clearance based on substantial equivalence:
1. A table of acceptance criteria and the reported device performance
The "acceptance criteria" for a 510(k) submission for a physical device like this are primarily demonstrated through substantially equivalent technical specifications and material properties to a predicate device, along with successful bench testing to ensure safety and functionality. The document presents a comparative table rather than an acceptance criteria table.
| Specification | Subject Device (neoLaser Laser Surgery Fibers) | Predicate Device (BeaMed Laser Surgery Fibers) | "Performance" / Outcome (Demonstrated Equivalence) |
|---|---|---|---|
| Indications for Use | General surgical applications (incision, vaporization, ablation, hemostasis, coagulation of soft tissue, endoscopic applications, etc.). Wavelength: 450nm-2100nm. Contact/non-contact mode. Used in general surgery, urology, gastroenterology, gynecology, dermatology, vascular surgery, neurosurgery, plastic surgery, ENT, endovenous occlusion, laser assisted lipolysis. SMA 905 connector. | Identical wording for Indications for Use. | Met: Substantially equivalent indications for use. |
| Fiber core material | Silica quartz glass | Silica quartz glass | Met: Identical material. |
| Fiber cladding material | silica quartz glass cladding and/or Hardclad | silica quartz glass cladding and/or Hardclad | Met: Identical material. |
| Buffer | silicone buffer | silicone buffer | Met: Identical material. |
| Jacket material | silicone / ETFE /polymide /nylon / acrylate / PVDF/ PU (with color additives) | silicone / ETFE /polymide /nylon / acrylate / PVDF/ PU (with color additives) | Met: Identical materials. |
| Maximal temperature | Nylon jacket: 176°F (80°C); ETFE jacket: 302°F (150°C) | Nylon jacket: 176°F (80°C); ETFE jacket: 302°F (150°C) | Met: Identical temperature tolerances. |
| Minimal bend radius | 51 x core diameter (short term); 121 x core diameter (long term) | 51 x core diameter (short term); 121 x core diameter (long term) | Met: Identical bend radius specifications. |
| Maximal laser power | Suitable for laser power up to 100W | Suitable for laser power up to 100W | Met: Identical power handling. |
| Shelf life | 5 years | 5 years | Met: Identical shelf life. |
| Numerical aperture range | 0.37 (for quartz/hardclad fibers); 0.22 (for quartz/quartz) | 0.37 (for quartz/hardclad fibers); 0.22 (for quartz/quartz) | Met: Identical numerical aperture range. |
| Core diameter range | 200 µm to 1000 µm | 200 µm to 1000 µm | Met: Identical core diameter range. |
| Outer diameter range | 240 µm to 1800 µm typically | 240 µm to 1800 µm typically | Met: Identical outer diameter range. |
| Distal fiber tip types | Flat, conical, ball, spherical or bended bare fibers, round or conical caps | Flat, conical, ball, spherical or bended bare fibers, round or conical caps | Met: Identical tip configurations. |
| Fiber tip outer diameter range | 1.0mm to 1.8mm | 1.0mm to 1.8mm | Met: Identical tip diameter range. |
| Length range | 6.5 feet (2 meters) to 9.9 feet (3 meters) | 6.5 feet (2 meters) to 9.9 feet (3 meters) | Met: Identical length range. |
| Emission angle range | Straight, forward directed cone or 60° cone angle from fiber axis, diffuse emission, and radial 360° | Straight, forward directed cone or 60° cone angle from fiber axis, diffuse emission, and radial emission of 360° | Met: Identical emission patterns. |
| Single/multiple use | Single use | Single use | Met: Identical use designation. |
| Sterility | Sterile by EO | Sterile by EO | Met: Identical sterilization method. |
| Packaging | Sterile, double pouched | Sterile, double pouched | Met: Identical packaging. |
| Proximal end | SMA 905 connector | SMA 905 connector | Met: Identical connector type. |
Performance Bench Testing included in the submission (serving as "proof"):
- Packaging seal strength
- Dye penetration test
- Packaging microbial barrier
- Shelf-life validation summary
- Sterilization process validation plan
- Sterilization process validation protocol
- Sterilization process validation report
- Sterility Assurance Level (SAL)
- EO-ECH residuals report
- LAL Endotoxin test
- Bioburden bare fibers test / Bioburden capped fibers tests
- Biocompatibility tests protocols & reports
- Thermal safety validation
The success of these tests (implicitly, meeting pre-defined thresholds for each) serves as the "reported device performance" that proves the device's safety and functionality for a 510(k) submission based on substantial equivalence.
2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)
Not applicable. This is for a physical device, and the submission explicitly states "Animal or clinical studies: None." The "tests" mentioned are bench tests on the device itself or its packaging/materials, not performance studies with human data. Therefore, concepts like sample size for a test set of patient data or data provenance (country, retrospective/prospective) are not relevant here.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)
Not applicable. No "ground truth" was established in the context of an AI/ML algorithm's performance against human expert interpretations or pathology. The evaluation is based on engineering and material specifications, and physical bench testing results.
4. Adjudication method (e.g. 2+1, 3+1, none) for the test set
Not applicable. There was no test set requiring expert adjudication.
5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
Not applicable. This device is not an AI/ML algorithm that assists human readers.
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
Not applicable. This device is not an AI/ML algorithm.
7. The type of ground truth used (expert concensus, pathology, outcomes data, etc)
Not applicable. The "ground truth" for this device's clearance is its conformity to engineering specifications, material standards, and successful completion of bench tests (e.g., sterilization efficacy, biocompatibility).
8. The sample size for the training set
Not applicable. There is no AI/ML training set for this physical device.
9. How the ground truth for the training set was established
Not applicable. There is no AI/ML training set or associated ground truth.
Ask a specific question about this device
(202 days)
Neonav is indicated for navigation and positioning of central venous access devices (CVADs) of at least 1Fr in size. Neonav provides real-time catheter tip location information by using the patient's cardiac electrical activity. Neonav is indicated for use as an alternative method to chest X-ray and fluoroscopy for all central venous access device tip placement confirmation.
In adult patients and in adolescents (greater than 12 through 21 years of age), Neonav can be used with CVADs such as peripherally inserted central catheters (PICCs), centrally inserted central catheters (CICCs), implantable ports, and hemodialysis catheters; in children (greater than 2 to 12 years of age), Neonav can be used with CICCs; in infants (greater than 1 month to 2 years of age) and in neonates (from birth to 1 month of age), Neonav can be used with PICCs and CICCs. In each specific age group, the CVAD type and size must be chosen and the CVAD must be used according to the CVAD's indications and instructions for use.
Limiting but not contraindicated situations for use of the Neonav are in patients where alterations of cardiac rhythm change the presentation of the P wave as in atrial flutter, severe tachycardia, and pacemaker driven rhythm. In such patients, who are easily identifiable prior to central venous access device insertion, the use of an additional method is required to confirm catheter tip location.
The Neonav ECG Tip Location System (Neonav) is a non-invasive medical device that analyzes electrocardiographic signals (ECG) to track the location of central venous access devices (CVADs) in patients' blood vessels during placement in real time via a display.
Catheter position in the vasculature is analyzed based on the patient's intravascular ECG (I-ECG). An I-ECG is recorded via the catheter tip from within the blood vessels of a patient. For the conductive fluid method, the sterile Neonav ECG Adapter Cable are used whereas for guidewire/stylet method, the sterile Neonav ECG clip cable is used. These components allow the electrical impulses detected at the catheter tip to be recorded by a non-sterile Acquisition Unit and analyzed by the Neonav Console to assist in determining the catheter tip position. The Neonav Controlled via a touch screen interface or a Remote enclosed in a sterile cover. The Neonav Console displays real-time surface ECG and I-ECG signals, highlighted QRS complex, max measured P-wave, the patient's heart rate, and other device performance indicators. A surface electrode is placed on the subject to act as a reference electrode. A second surface electrode is placed on the subject for noise reduction.
Neonav components are designed to attach easily to standard catheter and IV therapy components via standard luer lock connections. The only patient contacting component of the ECG Adapter. It has indirect contact with the patient via fluids and is composed of biocompatible polycarbonate and stainless steel.
The Neonav ECG Tip Location System is intended for navigation and positioning of central venous access devices (CVADs). The acceptance criteria and supporting study details are outlined below based on the provided text.
1. Table of Acceptance Criteria and Reported Device Performance
| Acceptance Criteria | Reported Device Performance |
|---|---|
| Biocompatibility | Met requirements of ISO 10993-1:2018 (Biological evaluation of medical devices), ISO 10993-7:2008 (Ethylene oxide sterilization residuals). The only patient-contacting component (ECG Adapter) is composed of biocompatible polycarbonate and stainless steel. |
| Sterilization Effectiveness | Met requirements of ISO 11135-7 and ISO 11135-2 (Sterilization of health-care products – Ethylene oxide). |
| Packaging Integrity and Shelf Life | Met requirements of ISO 11607-1:2019 and ISO 11607-2:2019 (Packaging for terminally sterilized medical devices), ASTM D543, ASTM F88/F88M-21, ASTM D4169-22, ASTM D7386-16, ASTM F2096-11, ISTA 3A 2018 General Simulation Performance Test. Accelerated aging was performed per ASTM F1980-21. |
| Electrical Safety & EMC | Met requirements of ANSI AAMI IEC 60601-1:2005 (Medical electrical equipment - General requirements for basic safety and essential performance) and IEC 60601-1-2:2020 (Electromagnetic disturbances - Requirements and tests), IEC/TR 60601-4-2. |
| Usability/Human Factors | Met requirements of IEC 60601-1-6:2020 (Usability) and IEC 62366-1:2020 (Application of usability engineering to medical devices). |
| Software Life Cycle Processes/MDR Compliance | Met requirements of IEC 62304:2015 (Medical device software life cycle processes). Followed guidance for Off-The-Shelf Software, Content of Premarket Submissions for Device Software Functions, and Cybersecurity in Medical Devices. |
| Specific Performance for ECG Monitoring | Met requirements of IEC 60601-2-27:2011 (Particular requirements for the safety, including essential performance, of electrocardiographic monitoring equipment). |
| Small-Bore Connectors | Met requirements of ISO 80369-7:2021 (Connectors for intravascular or hypodermic applications). |
| ECG Trunk Cables and Patient Leadwires | Met requirements of ANSI/AAMI EC53:2013 (R2020). |
| Ability to capture data from 1Fr catheters | Demonstrated in non-clinical bench tests. This supports the expanded indication for catheter sizes of 1Fr and above (compared to the predicate's 3Fr and above). |
| Real-time P-wave display and analysis | Displays real-time surface ECG and I-ECG signals, highlighted QRS complex, max measured P-wave, and heart rate for user decision-making for catheter navigation. |
2. Sample Size Used for the Test Set and Data Provenance
The provided text does not explicitly state a specific sample size for a clinical test set used to prove the device meets acceptance criteria related to its primary function of tip location accuracy. The document primarily references non-clinical bench tests and compliance with various standards.
There is a mention of "most current literature and effectiveness of PICCs in infants and neonates" supporting expanded indications, but this is not described as a direct device performance study.
3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications
The document does not specify the number of experts or their qualifications for establishing ground truth for any performance study.
4. Adjudication Method for the Test Set
The document does not specify any adjudication method used for a test set.
5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done, and the effect size of how much human readers improve with AI vs. without AI assistance
The document does not mention a Multi-Reader Multi-Case (MRMC) comparative effectiveness study, nor does it quantify any improvement in human reader performance with or without AI assistance. The Neonav system "displays the intravascular ECG to the user makes their own decision regarding catheter navigation of the real-time intravascular ECG signal," suggesting it's an assistance tool rather than a fully automated AI interpretation.
6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done
The document does not explicitly describe a standalone performance study of the algorithm without human-in-the-loop. The description of Neonav states it "displays the intravascular ECG to the user makes their own decision regarding catheter navigation of the real-time intravascular ECG signal," implying a human-in-the-loop operation. "Neonav does not provide computation of ECG signal for navigation. Neonav displays the intravascular ECG to the user makes their own decision regarding catheter navigation of the real-time intravascular ECG signal."
7. The Type of Ground Truth Used
The document does not explicitly state the type of ground truth used for performance evaluation. Given the device's function and the comparison to X-ray and fluoroscopy, it is highly probable that ground truth in any clinical validation would involve imaging modalities (e.g., chest X-ray or fluoroscopy confirmation) or direct physician assessment of catheter tip position, but this is not explicitly detailed in the provided text.
8. The Sample Size for the Training Set
The document does not provide any information regarding the sample size for a training set.
9. How the Ground Truth for the Training Set was Established
The document does not provide any information on how ground truth was established for a training set.
Ask a specific question about this device
(24 days)
NEO Pedicle Screw System™
The NEO Pedicle Screw System™, when used as a posterior pedicle screw system, is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion. The system is intended for posterior, non-cervical fixation for the following indications: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, curvatures (scoliosis, kyphosis), tumor, pseudarthrosis, and/or failed previous fusion.
When used in conjunction with BonOs® Inject Cement, the NEO Pedicle Screw System™ is intended to restore the integrity of the spinal column even in the absence of fusion for a limited time period in patients with advanced stage tumors involving the thoracic and lumbar spine in whom life expectancy is of insufficient duration to permit achievement of fusion. NEO Pedicle Screws augmented with BonOs® Inject Cement are for use with 5 mm to 8 mm screw diameters at spinal levels (thoracic and lumbar T1 to L5) where the structural integrity of the spine is not severely compromised.
BonOs® Inject
BonOs® Inject bone cement is indicated for the treatment of pathological fractures of the vertebral body due to osteoporosis, cancer, or benign lesions using vertebroplasty or balloon kyphoplasty procedure.
When used in conjunction with NEO Pedicle Screw System™ BonOs® Inject is intended to restore the integrity of the spinal column even in the absence of fusion for a limited time in patients with advanced stage tumors involving the thoracic and lumbar spine in whom life expectancy is of insufficient duration to permit achievement of fusion. NEO Pedicle Screws augmented with BonOs® Inject Cement are for use at spinal levels where the structural integrity of the spine is not severely compromised.
- BonOs® Iniect
BonOs® Iniect is a radiopaque, iniectable bone cement for use in spine surgery like percutaneous vertebral augmentation during vertebroplasty or kyphoplasty. It is a twocomponent system consisting of a powder and a liguid. Methylmethacrylate polymer is the primary constituent of the powder component. Zirconium dioxide is added as radiopacifier. Methylmethacrylate monomer is the primary constituent of the liquid component. Mixing the two separate sterile components, initially an injectable paste is produced which can be transferred into a syringe and which then can be injected under slight pressure into the vertebral body. After curing of the bone cement by exothermic polymerization it stabilizes the vertebral lesions and vertebral compression fractures.
- NEO Pedicle Screw System™
The NEO Pedicle Screw System™ has been optimized and consists of 27 pedicle and 8 iliac screws, rods and connectors which are available in different sizes. The system includes a reduced optimized trav of instruments providing options for open and MIS surgical techniques. The implants are all delivered sterile and ready to use. The relevant instruments are mainly delivered as single use, disposable and delivered sterile, just a few optional instruments are reusable and delivered non-sterile.
All the system components are made of materials compliant with ASTM and/or ISO standards. Screws and rods are made of titanium-alloy (Ti-6AI-4VELI) and comply with ISO 5832-3 or ASTM-F136. The screws are made out of a titanium alloy and delivered pre-mounted to a screw extender including a tissue dilator and sterile. The rods are made out of a titanium alloy or cobalt chrome alloy CoCrMo (ISO 5832-12, ASTM F1537) and delivered sterile, Connectors are made out of titanium alloy and delivered sterile.
The pedicle screws are offered in diameters of 4.5 – 8.0 mm and lengths of 25 - 55 mm. Illiac screws are offered in diameters of 8.0 mm and 10.0 mm and lengths of 70 – 100 mm. Three different types of rods are available: pre-bent, straight or special bent rod for S1/L5. All rods have a diameter of 5.5 mm. Pre-bent rods are offered in lengths of 35 – 100 mm, straight rods in lengths from 30 - 500 mm and the special-bent rod in either 30 or 40 mm length.
The NEO Pedicle Screw System™ provides immobilization and stabilization of spinal seqments in skeletally mature patients as an adjunct to fusion of the thoracic, lumbar, and/or sacral spine. The system can be used via an open or minimally invasive posterior approach. lliac screws shall be placed via Sacral Alar Iliac (SAI) and/or Posterior Superior Illiac Spine (PSIS) approach. The size and form of the device is adjusted to the morphology of the body and the surgical technique.
The provided text is an FDA 510(k) clearance letter and a 510(k) summary for a medical device called the "NEO Pedicle Screw System™" and "BonOs® Inject Bone Cement." This document details the administrative information, device description, indications for use, and a summary of performance data to support substantial equivalence to a predicate device.
However, the document specifies that "No clinical studies were conducted." This means that the information requested regarding acceptance criteria for a study proving device performance (especially for AI/algorithm-based devices), sample size for test and training sets, expert involvement, adjudication methods, MRMC studies, standalone algorithm performance, and ground truth establishment cannot be provided from this document.
The performance data mentioned in the document are limited to non-clinical testing, primarily focusing on mechanical performance, biological evaluation, and MRI compatibility. These types of tests are used to demonstrate that changes to the device (like new components or size extensions) do not negatively impact its existing, cleared performance characteristics, and that it is substantially equivalent to the predicate device.
Therefore, I cannot populate the requested table or answer the specific questions related to the acceptance criteria and study that proves the device meets the acceptance criteria in the context of an AI/algorithm-driven device's performance study, as this submission is for a physical orthopedic implant system, not a software or AI product requiring such a study.
Here's what can be inferred from the document regarding "acceptance criteria" and "proof" in the context of this device:
The "acceptance criteria" for the modifications introduced in this 510(k) submission are implicitly met if the device demonstrates substantial equivalence to its predicate device. This is primarily demonstrated through:
- Mechanical Performance: Meeting the requirements for pedicle screw spinal systems according to relevant ASTM and ISO standards (e.g., ASTM F1717 for dynamic compression bending). The document states: "Non-clinical performance testing demonstrate that the NEO Pedicle Screw System™ meets the requirements for Pedicle screw spinal systems according to Spinal System 510(k)s Guidance for Industry and FDA Staff Document issued on: May 3, 2004 and is substantially equivalent to its predicate devices."
- Biological Evaluation: Compliance with ISO 10993-1 series for the new components.
- MRI Compatibility: Meeting standards like ASTM F2052-15, ASTM F2182-11a, and ASTM F2119-07 (R2013).
- Functionality: Internal validation confirming new components function as intended.
Table of Acceptance Criteria (Implicit for a Mechanical Device) and Reported Performance:
| Acceptance Criteria Category | Specific Acceptance Criteria (Implicit from Submission) | Reported Device Performance (as stated in the document) |
|---|---|---|
| Mechanical Performance | Meets requirements of relevant standards (e.g., ASTM F1717 for dynamic compression bending for spinal systems). | "Finite element analysis and engineering rationales were performed to justify that the subject components do not represent a new worst case for mechanical performance. Additionally, the new axial connector was included in a construct tested according to ASTM F1717 for dynamic compression bending." "Mechanical testing also confirmed that the conical press-fit connection between the ball attachment and the 10.0 mm diameter iliac screw thread is sufficiently strong through measurement of the torque resistance of the assembled screw." "Results of these evaluations demonstrate substantially equivalent mechanical performance." |
| Biocompatibility | New components comply with ISO 10993-1 series. | "Biological evaluation has been performed for the new 10.0 mm diameter iliac screws of the modified NEO Pedicle Screw System™ in accordance with the ISO 10993-1 series." |
| Cleaning & Sterilization | Validation performed for new components. | "A new cleaning and sterilization validation has been performed for the new 10.0 mm diameter iliac screws." |
| MRI Compatibility | Evaluated against ASTM F2052-15, F2182-11a, F2119-07 (R2013). | "The new system components have been evaluated in regards to Magnetic field interactions ASTM F2052-15, MRI-related heating ASTM F2182-11a and Artifacts ASTM F2119-07 (R2013). Non-clinical testing demonstrated that the entire family of the NEO Pedicle Screw System™ is MRI conditional. The previous conclusions and MR conditional K222256 remain valid." |
| Functional Performance (Internal) | New axial connectors function as intended. | "An internal validation of the new axial connectors of the modified NEO Pedicle Screw System™ was performed and confirmed they function as intended." |
| Overall Equivalence | Demonstrated substantial equivalence to the predicate device in terms of intended use, material, design, and function. | "Based on the indications for use, technological characteristics, and comparison to predicate device, the subject modified BonOs® Inject Bone Cement, NEO Pedicle Screw System™ has been shown to be substantially equivalent to the currently cleared predicate device." |
Regarding the specific questions about an AI/algorithm performance study:
- Sample size for the test set and data provenance: Not applicable. No clinical or external algorithm performance test set was used.
- Number of experts used to establish the ground truth and qualifications: Not applicable.
- Adjudication method for the test set: Not applicable.
- MRMC comparative effectiveness study: Not applicable.
- Standalone (algorithm only without human-in-the-loop performance) study: Not applicable.
- Type of ground truth used: Not applicable. Ground truth for a physical device is often demonstrated by meeting design specifications and performance under defined test conditions (e.g., material strength and fatigue testing).
- Sample size for the training set: Not applicable. This is not an AI/ML device.
- How the ground truth for the training set was established: Not applicable.
In summary, the provided document is for a traditional mechanical medical device, not an AI/ML powered one. Therefore, the specific criteria and study details requested, which are pertinent to AI/ML device evaluations, are not present in this submission. The "proof" for this device's acceptance rests on its demonstration of substantial equivalence to a predicate device through non-clinical laboratory testing.
Ask a specific question about this device
(89 days)
NeoConvert Solution: The Neodent Implant System is intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices, such as artificial teeth, to restore chewing function. The NeoConvert Solution may be used with single-stage or two-stage procedures, for temporary multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading.
Direct Screw to MUA: The Neodent Implant System is intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices, such as artificial teeth, to restore chewing function. The Direct Screw to MUA may be used with single-stage or two-stage procedures, for screw-retained multi-unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading. All digitally designed personalized copings to be used with the Direct to Multi Unit Abutment Screw are intended to be sent to Straumann for manufacture at a validated milling center.
GM Attachment TiN 30°: The Neodent Implant System is intended to be surgically placed in the bone of the upper or lower jaw to provide support for prosthetic devices, such as artificial teeth, to restore chewing function. The GM Attachment TiN 30° may be used with single-stage or two-stage procedures, for multiple unit restorations, and may be loaded immediately when good primary stability is achieved and with appropriate occlusal loading.
This premarket notification includes the following additions to the Neodent Implant System: NeoConvert Solution, Direct Screw to MUA, GM Attachment TiN 30°. The Neodent Multi-Unit Abutments proposed on this submission are similar to devices already cleared in previous submissions of Neodent Implant System, according to predicate devices described above. This submission intends to expand the portfolio of Neodent Abutments with these new solutions for multi-unit restorations, to provide more treatment options to customers. The NeoConvert Solution is a technique comprised by some abutments (not subject of this submission) used for converting removable temporary prosthesis into a screw-retained fixed temporary prosthesis. The Direct Screw to MUA is a prosthetic component designed to fix planned and digitally designed multi-unit milled restorations directly onto mini or micro abutments, eliminating the need for using the passive seating cylinder to restore chewing function. The GM Attachment TiN 30° is a prosthetic component used to stabilize implant-mucosa-supported removable full prosthesis (retained on the implant and supported on the mucosa), on implants installed in the maxilla or mandible. Although all these three new solutions are compatible with the same implants and components of Neodent Implant System and used for multiple unit rehabilitation, they are not used in conjunction with each other.
The provided text describes a 510(k) premarket notification for the "Neodent Implant System," focusing on the NeoConvert Solution, Direct Screw to MUA, and GM Attachment TiN 30°. This document details the device's technical characteristics, intended use, and its substantial equivalence to previously cleared predicate devices.
However, the provided text does not contain information about acceptance criteria and a study proving a device meets those criteria in the context of an AI/ML medical device submission. The document is a traditional 510(k) submission for dental implants and abutments, which are physical medical devices, not AI/ML software. Therefore, the specific requirements for an AI/ML device study (such as sample sizes for test and training sets, expert qualifications for ground truth, MRMC studies, or standalone performance) are not applicable or present in this document.
The "Performance Testing" section (pages 15-16) describes bench testing (dynamic fatigue, torsion, SEM images), MRI compatibility testing, biocompatibility testing, sterilization validation, and shelf-life testing for the physical dental implant components. These are standard performance tests for this type of physical device, not AI/ML algorithm validation.
Therefore, I cannot provide a table of acceptance criteria and a study proving the device meets acceptance criteria as typically outlined for an AI/ML medical device, as this information is not present in the provided document. The document focuses on demonstrating substantial equivalence of a physical dental device to predicate devices through engineering and material testing.
Ask a specific question about this device
(54 days)
The device is indicated to be used for:
• Improvement of abdominal tone, strengthening of the abdominal muscles, development of firmer abdomen.
· Strengthening, Toning and Firming of buttocks and thighs.
·Improvement of muscle tone and firmness, for strengthening muscles in arms.
Not Found
I am sorry, but based on the provided text, there is no information about acceptance criteria or a study that proves the device meets specific acceptance criteria.
The document is a 510(k) clearance letter from the FDA for the medical device "Neo Sculptor (OF-NEO001)". It states that the device is substantially equivalent to legally marketed predicate devices and outlines the indications for use.
However, it does not include:
- A table of acceptance criteria and reported device performance.
- Details about sample sizes, data provenance, or the number/qualifications of experts used for a test set.
- Information on adjudication methods, MRMC studies, or standalone algorithm performance.
- The type of ground truth used, or details about the training set size or how its ground truth was established.
The letter primarily focuses on regulatory clearance, general controls, and compliance requirements rather than specific performance study data or acceptance criteria.
Ask a specific question about this device
Page 1 of 24