Search Filters

Search Results

Found 7 results

510(k) Data Aggregation

    K Number
    K243308

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-12-20

    (60 days)

    Product Code
    Regulation Number
    888.3030
    Age Range
    All
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The SALGINA 2.5mm Distal Radius System is indicated for

    • · Intra-articular fractures of the Distal Radius.
    • · Extra-articular fractures of the Distal Radius

    The CASCELLA 3.5mm Superior Clavicle System is indicated for:

    • fixation of fractures of the clavicle shaft
    • fixation of fractures of the lateral clavicle
    • malunions of the clavicle
    • · non-unions of the clavicle

    The LEPORELLO 3.5mm Olecranon System is indicated for

    • · fractures
    • osteotomies
    • nonunions

    of the olecranon and proximal ulna.

    Device Description

    The Bonebridge Osteosynthesis Plating System is intended for treating fractures of various bones. It consists of plates, locking and non-locking screws for fixation and corresponding instruments. The plating system is further subdivided into variants/types based on the anatomical location of the fracture.

    Plates and screws are made of stainless steel (ISO 5832-1 or ASTM F138 or ASTM F139) or pure titanium (ASTM F67 or ISO 5832-2). All materials used are biocompatible, corrosion-resistant and nontoxic in a biological environment. Surgical instruments are made of stainless steel (ASTM F899. ISO 7153-1. ISO 5832-1. and ASTM F138/139). medical grade PEEK, medical grade EPDM terpolymer, or medical grade silicone. All plates are sterilized with gamma irradiation and delivered sterile. Screws and instruments are delivered non-sterile. Devices supplied in a non-sterile condition must be cleaned and steam sterilized prior to surgical use. Non-clinical testing has demonstrated the devices are MR Conditional.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the Bonebridge Osteosynthesis Plating System. The focus of the submission is on demonstrating substantial equivalence to predicate devices through non-clinical testing. This document does NOT describe a study that proves a device meets acceptance criteria for an AI/software-as-a-medical-device (SaMD) product, nor does it provide information relevant to a multi-reader, multi-case (MRMC) study or the establishment of ground truth by expert consensus for an AI model.

    The information provided pertains to the mechanical, material, and labeling aspects of a physical bone fixation system, not a diagnostic AI device. Therefore, I cannot extract the requested information regarding AI device performance, sample sizes for test/training sets, expert qualifications, ground truth establishment, or MRMC study details from this document.

    The document only states that:

    • Clinical investigations were not required due to a clinical evaluation including a literature review and verification/validation activities.
    • Usability evaluation was successfully completed in accordance with IEC 62366-1, with no significant usability issues identified.

    The non-clinical tests summarized are related to the physical properties and safety of the implantable device:

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document doesn't present acceptance criteria in a table format with specific quantitative metrics for the "acceptance criteria" and "reported device performance" in the context of an AI device. Instead, it lists various non-clinical tests performed on the physical implant and states whether they "Pass" or "Fail" against their respective standards. These are not performance metrics for an AI algorithm.

    Non-Clinical TestAcceptance Criterion (Implicit)Reported Device Performance
    Sterilization ValidationMinimal dose of 25kGy validated using VDmax25 method (ISO 11137-2) for SAL of 10-6. Cleaning and sterilization procedures validated (ISO 17664, ISO 17665-1) at 132°C for 4 minutes with 20 min drying time.Pass
    Packaging ValidationValidation of sterile packaging in accordance with ISO 11607 1/2 and ASTM F1980. Transport simulation (ISTA 2A) followed by Dye-Penetration (ASTM F1929), Visual inspection (ASTM F1886/1886M), Seal strength (ASTM F88/F88M), and Microbial barrier testing (DIN 58953-6, Chapter 2.14).Pass
    BiocompatibilityBiological Evaluation and toxicological risk assessment for biological safety according to ISO 10993-series and FDA guidance.Pass
    Mechanical TestingStatic and dynamic comparative testing demonstrating substantial equivalence of each subject plate variant to corresponding predicate devices with respect to maximum force (static) and maximum force for a given number of cycles (dynamic). Predefined acceptance criteria for mechanical performance successfully met. Design verification successfully completed for compatibility, anatomical shape, and appearance.Pass
    MRI SafetyAssessment of displacement force and torque effects in the main static magnetic field at 3Tesla (ASTM F2052-21, ASTM F2213-17). Assessment of heating effects due to RF-field during MR scans at 1.5Tesla and 3Tesla (ASTM F2182-19). Assessment of image artifacts at 3Tesla (ASTM F3110-24). The tested implant and associated product family can be claimed as MR conditional.Pass

    2. Sample size used for the test set and data provenance:
    Not applicable. This is for a physical device, and no AI test set is mentioned.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:
    Not applicable. Ground truth for an AI algorithm is not established in this document.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:
    Not applicable.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:
    No MRMC study was done or mentioned, as this is not an AI device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:
    Not applicable.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):
    Not applicable.

    8. The sample size for the training set:
    Not applicable.

    9. How the ground truth for the training set was established:
    Not applicable.

    In summary, the provided FDA 510(k) clearance letter and associated summary pertain to the substantial equivalence of a physical bone fixation system with existing predicate devices based on non-clinical engineering and material properties testing. It does not contain any information about acceptance criteria or studies related to AI or software-as-a-medical-device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K242399

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-10-31

    (79 days)

    Product Code
    Regulation Number
    888.3030
    Age Range
    18 - 120
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Bonebridge POYA 3.5mm Posteromedial Tibia System is intended for adult patients and indicated for internal fixation of posteromedial proximal tibia fractures, including buttressing of fractures of the proximal and metaphyseal areas of the tibia. Additionally, the longer plates are indicated for fractures extending to the tibial shaft.

    The POYA 3.5mm Medial Proximal Tibia System is intended for adult patients and indicated to buttress metaphyseal fractures of the medial tibia plateau, split- type fractures of the medial tibia plateau, medial split fractures with associated depressions and split or depression fractures of the medial tibia plateau. Also, for use in the fixation of osteopenic bone and fixation of nonunions and malunions of the medial proximal tibia.

    The SALTI 2.5/3.5mm Ankle System is intended for fixation of the ankle in adult patients and particularly in osteopenic bone. Specifically,

    • the Medial and Anterolateral Distal Tibia Plates are intended for fixation of osteotomies, fractures, nonunions, malunions, and replantations of bones and bone fragments of the diaphyseal and metaphyseal regions of the distal tibia.
    • . The Posterior Distal Tibia Plate is intended to buttress partial articular fractures and bone fragments of the distal tibia.
    • . The Lateral Distal Fibula Plates are intended for fixation of osteotomies, fractures, nonunions, malunions, and replantations of bones and bone fragments of the diaphyseal and metaphyseal regions of the distal fibula.
    Device Description

    The Bonebridge Osteosynthesis Plating System is intended for treating fractures of various bones. It consists of plates, locking and non-locking screws for fixation and corresponding instruments. The plating system is further subdivided into variants/types based on the anatomical location of the fracture.

    Plates and screws are made of stainless steel (ISO 5832-1 or ASTM F138 or ASTM F139) or pure titanium (ASTM F67 or ISO 5832-2). All materials used are biocompatible, corrosion-resistant and nontoxic in a biological environment. Surgical instruments are made of stainless steel (ASTM F899, ISO 7153-1, ISO 5832-1, and ASTM F138/139), medical grade PEEK, medical grade EPDM terpolymer, or medical grade silicone, All plates are sterilized with gamma irradiation and delivered sterile. Screws and instruments are delivered non-sterile. Devices supplied in a non-sterile condition must be cleaned and steam sterilized prior to surgical use. Non-clinical testing has demonstrated the devices are MR Conditional.

    AI/ML Overview

    The provided document is a 510(k) premarket notification letter from the FDA for a medical device called the "Bonebridge Osteosynthesis Plating System." This type of document is centered on demonstrating substantial equivalence to existing legally marketed devices, rather than establishing acceptance criteria and proving performance through novel clinical studies in the way one might expect for a new, innovative diagnostic or AI device.

    Therefore, the information typically requested in your prompt regarding acceptance criteria and performance against those criteria (such as sample sizes for test/training sets, expert ground truth, adjudication methods, MRMC studies, standalone performance, etc.) is not present in this document.

    The document primarily focuses on non-clinical tests to show that the new device is as safe and effective as its predicates. Here's a breakdown of the available information in relation to your request:


    1. Table of acceptance criteria and the reported device performance:

    The document states that "All predefined acceptance criteria were successfully met" for mechanical testing, but it does not explicitly list these acceptance criteria or the specific numerical performance values for each. It only reports a "Pass" for each category of non-clinical testing.

    Test CategoryAcceptance Criteria (Explicitly stated in document?)Reported Device Performance
    Sterilization validationMinimal dose of 25kGy (for gamma irradiation)Pass
    SAL of 10^-6 (for gamma irradiation)Pass
    132°C (270F) for 4 minutes and 20 min drying time (for steam sterilization)Pass
    Packaging validationN/A (referenced standards ISO 11607 1/2, ASTM F1980, ISTA 2A, ASTM F1929, ASTM F1886/1886M, ASTM F88/F88M, DIN 58953-6 Chapter 2.14)Pass
    BiocompatibilityN/A (referenced standards ISO 10993-series and FDA guidance)Pass
    Mechanical testingSubstantially equivalent to predicate devices for maximum force (static) and maximum force for a given number of cycles (dynamic).Pass
    MRI safety"MR conditional" considering local SARPass
    Assessment of displacement force and torque effects (ASTM F2052-21, ASTM F2213-17)Pass
    Assessment of heating effects (ASTM F2182-19)Pass
    Assessment of image artifacts (ASTM F2119-07 (2013))Pass
    Usability testsNo significant usability issues (based on primary objectives prior Application/ Usability Risk Assessment update)Successful

    2. Sample size used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective):

    This information is not provided in the document. The document describes mechanical testing and refers to "design verification" which would involve testing prototypes, but does not detail the sample sizes for these tests, nor does it refer to patient data for performance evaluation.


    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g., radiologist with 10 years of experience):

    This information is not applicable/not provided. The "ground truth" concept is highly relevant for diagnostic devices or AI, where human experts (e.g., radiologists, pathologists) determine the correct diagnosis or outcome. For a bone plating system, performance is primarily assessed through biomechanical testing and material properties, not through expert-labeled patient data.


    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set:

    This information is not applicable/not provided for the reasons stated above. Adjudication relates to resolving disagreements among experts when establishing ground truth.


    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    This is not applicable/not provided. MRMC studies are typically for evaluating the impact of AI or diagnostic tools on human reader performance, which doesn't apply to a bone plating system.


    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

    This is not applicable/not provided. This device is a physical bone plating system, not an algorithm.


    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    As discussed, the concept of "ground truth" in the diagnostic/AI sense is not applicable here. The "truth" for this device's performance is derived from standardized engineering and material testing (e.g., mechanical load tests, biocompatibility assessments, sterilization efficacy).


    8. The sample size for the training set:

    This information is not applicable/not provided. There is no "training set" for this type of physical medical device. Training sets are relevant for machine learning algorithms.


    9. How the ground truth for the training set was established:

    This information is not applicable/not provided.


    In summary: The document is a 510(k) submission for a bone plating system and focuses on demonstrating substantial equivalence through non-clinical testing. It does not contain information related to acceptance criteria or studies in the context of diagnostic or AI device performance as described in your prompt. The "acceptance criteria" where mentioned implicitly refer to passing engineering specifications and regulatory standards.

    Ask a Question

    Ask a specific question about this device

    K Number
    K213864

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2022-09-02

    (266 days)

    Product Code
    Regulation Number
    888.3030
    Age Range
    All
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The SALGINA® 2.5mm Volar Distal Radius System is indicated for

    • · Intra-articular fractures of the Distal Radius
    • · Extra-articular fractures of the Distal Radius

    The CASCELLA® 3.5mm Superior Clavicle System is indicated for:

    • fixation of fractures of the clavicle shaft
    • · fixation of fractures of the lateral clavicle
    • malunions of the clavicle
    • · non-unions of the clavicle

    The TAMINA® and TAMINA®TF Proximal Humerus System is indicated for:
    · Dislocated two-, three-, and four fractures of the proximal humerus including fractures involving osteopenic bone.

    • · Pseudarthroses (non-unions) of the proximal humerus
    • · Osteotomies of the proximal humerus

    The POYA® 3.5mm Lateral Proximal Tibia System is indicated for the internal fixation of fractures of the proximal tibia in adults and skeletally mature adolescents including:

    • simple fractures
    • · comminuted fractures
    • · lateral wedge, medial wedge as well as bicondylar combination of lateral and medial wedge fractures
    • · depression fractures
    • · periprosthetic fractures
    • · nonunions, malunions, tibial osteotomies and osteopenic bone

    The POYA® 3.5mm Posteromedial Tibia System is indicated for internal fixation of posteromedial proximal tibia fractures including buttressing of fractures of the proximal areas of the tibia.

    The DALVAZZA® 2.5mm Distal Ulna System is indicated for

    • · fixation of fractures
    • nonunions
      of the distal ulna.

    The LEPORELLO® 3.5mm Olecranon System is indicated for

    • fractures
    • · osteotomies
    • non-unions
      of the olecranon and proximal ulna.
    Device Description

    The Bonebridge Osteosynthesis Plating System is intended for treating fractures of various bones. It consists of plates, locking and non-locking screws for fixation and corresponding instruments. The plating system is further subdivided into variants/types based on the anatomical location of the fracture.

    Plates and screws are made of stainless steel (ISO 5832-1 or ASTM F138 or ASTM F139) or pure titanium (ASTM F67 or ISO 5832-2). All materials used are biocompatible, corrosion-resistant and nontoxic in a biological environment. Surgical instruments are made of stainless steel (ISO 5832-1 or ASTM F138 or ASTM F899), medical grade PEEK, medical grade EPDM terpolymer, or medical grade silicone.

    All plates are sterilized with gamma irradiation and delivered sterile. Screws and instruments are delivered non-sterile. Devices supplied in a non-sterile condition must be cleaned and steam sterilized prior to surqical use. Non-clinical testing has demonstrated the devices are MR Conditional.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the Bonebridge Osteosynthesis Plating System. This type of submission focuses on demonstrating substantial equivalence to a legally marketed predicate device, rather than proving independent effectiveness through a clinical study with detailed acceptance criteria for diagnostic performance. Therefore, the information typically requested regarding acceptance criteria for diagnostic accuracy, sample sizes for test/training sets, expert ground truth establishment, or multi-reader multi-case studies is not directly applicable or available in this document.

    However, the document does list various performance tests conducted to establish substantial equivalence. I will present the information related to device performance and the testing conducted, framed within the principles of acceptance criteria where possible.

    Here's a breakdown of the requested information based on the provided text, acknowledging the limitations inherent in a 510(k) summary:

    1. Table of acceptance criteria and reported device performance:

    The document doesn't explicitly state "acceptance criteria" with numerical thresholds for performance like sensitivity or specificity, as it's not a diagnostic device. Instead, it describes various engineering and material tests. The acceptance criterion for these tests is generally that the device performs equivalently to or better than the predicate device, or meets relevant international standards.

    Test CategoryAcceptance Criteria (Implied from text)Reported Device Performance
    Sterilization ValidationGamma irradiation: Achieve a Sterility Assurance Level (SAL) of 10^-6 as per ISO 11137-2 (VDmax25 method).Steam sterilization: Successfully validated according to ISO 17664 and ISO 17665-1 at 132°C (270F) for 4 minutes with 20 min drying time.Gamma irradiation: The minimal dose of 25kGy is validated using VDmax25 method as described in ISO 11137-2 and confirmed a Sterility Assurance Level SAL of 10-6.Steam sterilization: Cleaning and sterilization procedures have been successfully validated in accordance with ISO 17664 and ISO 17665-1 at 132°C (270F) for 4 minutes and 20 min drying time.
    Packaging ValidationSuccessful validation according to ISO 11607 1/2 and ASTM F1980. Includes transport simulation (ISTA 2A) followed by specific packaging verification tests (Dye-Penetration, Visual Inspection, Seal Strength, Microbial Barrier Testing).Validation of the sterile packaging has been successfully performed in accordance with ISO 11607 1/2 and ASTM F1980. Furthermore, a transport simulation was conducted according ISTA 2A followed by these packaging verification tests: Dye-Penetration, ASTM F1929; Visual inspection, ASTM F1886/1886M; Seal strength, ASTM F88/F88M; Microbial barrier testing, DIN 58953-6, Chapter 2.14.
    Mechanical TestingPlates: Predefined acceptance criteria for static and dynamic testing successfully met, including statistical analysis and comparative testing to predicate devices.Screws: Successfully tested in accordance with ASTM F543 and includes comparative testing to predicate devices.Design Verification: Compatibility of implants and instruments, and assessment of anatomical shape and appearance successfully completed.Plates: Static and dynamic testing has been performed and included statistical analysis and comparative testing to the predicate devices. The predefined acceptance criteria were successfully met.Screws: Tested successfully in accordance with ASTM F543: Standard Specification and Test Methods for Metallic Medical Bone Screws and includes comparative testing to predicate devices.Design verification was successfully completed and included compatibility of implants and instruments as well as assessment of anatomical shape and appearance.
    MRI SafetyMR conditional status based on tests for displacement force and torque, heating effects due to RF-field, and image artifacts. (Tests according to ASTM F2052-15, ASTM F2213-17, ASTM F2182-11a, ASTM F2119-07).The Bonebridge Osteosythesis Plating System is MR conditional considering local SAR based on the following tests: Assessment of displacement force and torque effects in the main static magnetic field at 3Tesla. Additionally, the expected magnetic force in a stronger magnetic field gradient of 30T/m was extrapolated. (According to ASTM F2052-15 and ASTM F2213-17); Assessment of heating effects due to the RF-field during MR scans at 1.5Tesla and 3Tesla according to ASTM F2182-11a; Assessment of image artifacts at 3Tesla according to ASTM F2119-07 (2013).
    UsabilityNo significant usability issues are identified, meeting predefined acceptance criteria from the study. Study participants must be able to use the products safely and effectively.Summative usability evaluation studies in accordance with IEC 62366-1 support that there are no significant usability issues due to the study acceptance criteria of the primary objectives prior Application/ Usability Risk Assessment update. Therefore, the summative usability evaluation studies of the Bonebridge Osteosythesis Plating System are considered as successful. The study participants were able to use the products safely and effectively.
    BiocompatibilityAssessment performed in accordance with ISO 10993-1.A biological assessment has been performed in accordance with ISO 10993-1.
    Clinical EvaluationNot required if existing interventions for relevant indications match surgical technique, device design, and material, and if verification and validation activities are conclusive.Based on the results of the literature review and the results of verification and validation activities it has been concluded that clinical investigations are not required, since surgical technique, device design and material match established interventions for the relevant indications.

    2. Sample size used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective)

    This information is not provided in the given text. The document refers to "testing" performed (e.g., static and dynamic testing for plates, testing for screws, packaging validation, MRI safety tests), but it does not specify the sample sizes of devices or materials used for these engineering tests. There's no "test set" in the context of diagnostic data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g., radiologist with 10 years of experience)

    This information is not applicable/provided as this is an orthopedic implant (osteosynthesis plating system), not an AI/diagnostic device that would require expert-established ground truth for a test set. Usability studies were conducted with "study participants," but their qualifications or number for establishing ground truth are not detailed.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    This information is not applicable/provided. As noted above, this device is not an AI/diagnostic device.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This information is not applicable/provided. This is an orthopedic implant, not an AI-assisted diagnostic tool.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    This information is not applicable/provided. This is an orthopedic implant, not an algorithm/AI.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    This information is not applicable/provided in the context of diagnostic accuracy. For the engineering tests, the "ground truth" would be established by the specifications of the materials, the design requirements, and the standards (e.g., ISO, ASTM) against which the device was tested. For usability, the ground truth is the successful and safe operation by participants.

    8. The sample size for the training set

    This information is not applicable/provided. This device is an orthopedic implant and does not involve AI or a "training set" in the machine learning sense.

    9. How the ground truth for the training set was established

    This information is not applicable/provided. As above, it is not an AI device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K200504

    Validate with FDA (Live)

    Date Cleared
    2020-07-29

    (149 days)

    Product Code
    Regulation Number
    874.3340
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Bonebridge is intended to improve hearing for patients with conductive or mixed hearing losses, bilateral fitting, and single-sided deafness.

    INDICATIONS:
    The Bonebridge bone conduction hearing implant system is intended for the following patients and indications:

    • Patients 12 years of age or older.
    • Patients who have a conductive or mixed hearing loss and still can benefit from sound amplification. The pure tone average (PTA) bone conduction (BC) threshold (measured at 0.5, 1, 2 and 3kHz) should be better than or equal to 45 dB HL.
    • Bilateral fitting of the Bonebridge is intended for patients having a symmetrically conductive or mixed hearing loss. The difference between the left and right sides' BC thresholds should be less than 10 dB on average measured at 0.5, 1, 2 and 3kHz, or less than 15 dB at individual frequencies.
    • Patients who have profound sensorineural hearing loss in one ear and normal hearing in the opposite ear (i.e., single-sided deafness or "SSD"). The pure tone average air conduction hearing thresholds of the hearing ear should be better than or equal to 20 dB HL (measured at 0.5, 1, 2 and 3kHz).
    • The Bonebridge for SSD is also indicated for any patient who is indicated for an air-conduction contralateral routing of signals (AC CROS) hearing aid, but who for some reason cannot or will not use an AC CROS.
    • Prior to receiving the device, it is recommended that an individual has experience with appropriately fit air conduction or bone conduction hearing aids.
    Device Description

    The MED-EL BONEBRIDGE System augments hearing by providing acoustic input to the inner ear via bone conduction. The MED-EL BONEBRIDGE System consists of two major components: The implant, called Bone Conduction Implant (BCI) and the external audio processor, e.g. the SAMBA 2 BB. The SYMFIT 8.0 software enables the fitting and configuration of the SAMBA 2 BB audio processor and is indicated for professional use only, i.e. used by hearing healthcare professionals during a fitting session of the external audio processor SAMBA 2 BB. Additionally, the SAMBA 2 GO and SAMBA 2 Remote are also subject to this 510(k). Both devices offer a convenient option to adjust simple, pre-defined settings of the compatible SAMBA 2 BB audio processor. Additionally, the SAMBA 2 GO can also be used as an assistive streaming device. The MED-EL BONEBRIDGE System is an active implantable bone conduction hearing system. The MED-EL BONEBRIDGE System is a prescription device consisting of an implanted transducer, implanted electronics components, and an audio processor. The active implantable bone conduction hearing system is intended to compensate for conductive or mixed hearing losses by conveying amplified acoustic signals to the cochlea via mechanical vibrations on the skull bone.

    AI/ML Overview

    The provided text is a 510(k) summary for the MED-EL Elektromedizinische Geraete GmbH's BONEBRIDGE System components (SAMBA 2 BB, SYMFIT 8.0, SAMBA 2 GO, SAMBA 2 Remote). This document focuses on demonstrating substantial equivalence to a predicate device rather than providing a detailed study proving acceptance criteria for a novel device or AI.

    Therefore, much of the requested information, such as sample sizes for test sets, data provenance, number of experts for ground truth, adjudication methods, MRMC studies, standalone algorithm performance, and training set details, is not applicable or not present in this type of regulatory submission.

    The document primarily describes comparative bench testing against a predicate device.

    Here's the information that can be extracted from the provided text based on your request:

    1. A table of acceptance criteria and the reported device performance

    The document does not explicitly state quantitative acceptance criteria or specific numerical performance metrics in the format of a table you've requested. Instead, it relies on demonstrating that the new devices perform "as intended" and are "at least as safe and effective" as the predicate devices, based on various bench tests.

    Acceptance Criteria (Inferred from comparison to predicate)Reported Device Performance
    Same basic design concept and technological characteristics as predicate.SAMBA 2 BB maintains basic design, electronics, housing material, and similar stimulation strategies to predicate. Differences (battery door, dimensions, weight, magnet strength, microphone protection, microphone type, IP rating) do not affect safety or effectiveness.
    Same energy source as predicate.SAMBA 2 BB uses the same energy source as predicate.
    Biocompatible materials in skin contact.Main materials in skin contact for SAMBA 2 BB evaluated per 10993-1 and shown to be biocompatible and safe. Material identical to predicate.
    Signal processing maintains basic functionality and overall performance compared to predicate.SAMBA 2 BB signal processing features same basic functionality as predicate, with new optional noise reduction, compression settings, and improved acoustic classification. Bench testing confirms differences do not affect safety or effectiveness, and overall performance remains identical.
    Connectivity options maintain functionality compared to predicate.SAMBA 2 BB offers identical connectivity options as predicate, plus an acoustic interface for MED-EL Wireless Accessories. Bench testing confirms differences do not affect safety or effectiveness.
    SYMFIT 8.0 software maintains basic working principle, operational environment, moderate level of concern, and purpose as predicate.SYMFIT 8.0 works to program SAMBA 2 BB, maintains basic working principle and operational environment. Software architecture improved, workflow identical but with adapted UI. Bench and usability testing confirm differences do not affect safety or effectiveness.
    SYMFIT 8.0 fitting features maintain basic functionality and overall performance compared to predicate.SYMFIT 8.0 fitting features provide same basic functionality as predicate, with new optional fine-tuning for compression settings. Bench testing confirms differences do not affect safety or effectiveness, and overall performance remains identical.
    SAMBA 2 GO design concept and SAMBA 2 Remote app-specific design do not impact safety or effectiveness.SAMBA 2 GO has slightly updated design (neckloop); SAMBA 2 Remote is a mobile app. Bench testing confirms differences do not affect safety or effectiveness.
    SAMBA 2 GO and SAMBA 2 Remote remote-control features maintain functionality compared to predicate.SAMBA 2 GO and SAMBA 2 Remote provide identical remote-control features, with SAMBA 2 Remote offering an additional "Sound Balancing" feature for comfort. Bench testing confirms differences do not affect safety or effectiveness.
    SAMBA 2 GO and SAMBA 2 Remote connectivity maintains functionality compared to predicate.SAMBA 2 GO uses identical wireless connection, and enables streaming (non-medical purpose). SAMBA 2 Remote uses acoustic interface. Bench testing confirms differences do not affect safety or effectiveness.
    Device components meet established specifications for safe and consistent performance.Non-clinical bench tests (electrical, performance, compatibility, reliability, shipping, environmental, electrical safety, EMC, software testing) demonstrated that all components meet established specifications ensuring consistent and safe performance for intended use.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document mentions "bench testing" and "non-clinical performance testing." This usually implies testing on physical devices or software in a laboratory setting, not patient data. Therefore, concepts like sample size of a patient test set, data provenance (country, retrospective/prospective), etc., are not explicitly provided or relevant in the context of this 510(k) summary, which focuses on device modifications and substantial equivalence via engineering and verification testing.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    Not applicable. Ground truth typically refers to clinical data interpreted by experts. This document describes bench testing of hardware and software components.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable. Adjudication methods are for human interpretation of clinical data sets.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is not an AI-assisted diagnostic device, and no MRMC study is mentioned. The device is a hearing aid system.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This refers to software performance, specifically for SYMFIT 8.0, SAMBA 2 GO, and SAMBA 2 Remote. The document states "Software testing according to software's defined Level of Concern" was conducted. This implies standalone testing of the software components. However, specific performance metrics for the software in a "standalone" fashion are not provided, beyond confirming it meets specifications and does not affect safety or effectiveness compared to the predicate.

    7. The type of ground truth used (expert concensus, pathology, outcomes data, etc)

    For the "bench testing," the "ground truth" would be established engineering specifications, industry standards, and the performance of the predicate device. This is not expert consensus, pathology, or outcomes data.

    8. The sample size for the training set

    Not applicable. This device is not an AI/Machine Learning device that requires a training set in the typical sense.

    9. How the ground truth for the training set was established

    Not applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    K191457

    Validate with FDA (Live)

    Date Cleared
    2019-09-18

    (110 days)

    Product Code
    Regulation Number
    874.3340
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    INTENDED USE:

    The Bonebridge is intended to improve hearing for patients with conductive or mixed hearing losses, bilateral fitting, and single-sided deafness.

    INDICATIONS:

    The Bonebridge bone conduction hearing implant system is intended for the following patients and indications:

    • Patients 12 years of age or older.

    • Patients who have a conductive or mixed hearing loss and still can benefit from sound amplification. The pure tone average (PTA) bone conduction (BC) threshold (measured at 0.5, 1, 2 and 3 kHz) should be better than or equal to 45 dB HL.

    • Bilateral fitting of the Bonebridge is intended for patients having a symmetrically conductive or mixed hearing loss. The difference between the left and right sides' BC thresholds should be less than 10 dB on average measured at 0.5, 1, 2 and 3 kHz, or less than 15 dB at individual frequencies.

    • Patients who have profound sensorineural hearing loss in one ear and normal hearing in the opposite ear (i.e., single-sided deafness or "SSD"). The pure tone average air conduction hearing thresholds of the hearing ear should be better than or equal to 20 dB HL (measured at 0.5, 1, 2 and 3 kHz).

    -The Bonebridge for SSD is also indicated for any patient who is indicated for an air-conduction contralateral routing of signals (AC CROS) hearing aid, but who for some reason cannot or will not use an AC CROS.

    • Prior to receiving the device, it is recommended that an individual has experience with appropriately fit air conduction or bone conduction hearing aids.
    Device Description

    Not Found

    AI/ML Overview

    The provided text is a 510(k) clearance letter from the FDA for a medical device called the "BONEBRIDGE System." This document primarily focuses on the regulatory clearance process, outlining the device's intended use, indications, and contraindications. It does not contain any information about acceptance criteria, study methodologies (like sample sizes, expert qualifications, adjudication methods), or performance data that would prove the device meets specific acceptance criteria.

    The purpose of a 510(k) submission is to demonstrate substantial equivalence to a legally marketed predicate device, not necessarily to present detailed performance study results against predefined acceptance criteria in the format requested. While performance data may have been submitted as part of the 510(k) application, that information is not present in this public clearance letter.

    Therefore, I cannot fulfill your request for the detailed information regarding acceptance criteria and the study proving the device meets them based solely on the provided text. The document is a regulatory communication, not a clinical study report.

    Ask a Question

    Ask a specific question about this device

    K Number
    K183373

    Validate with FDA (Live)

    Device Name
    Bonebridge
    Date Cleared
    2019-03-07

    (91 days)

    Product Code
    Regulation Number
    874.3340
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The BONEBRIDGE bone conduction hearing implant system is intended for the following patients and indications:

    • · Patients 12 years of age or older.
      · Patients who have a conductive or mixed hearing loss and still can benefit from sound amplification. The pure tone average (PTA) bone conduction (BC) threshold (measured at 0.5,1, 2, and 3 kHz) should be better than or equal to 45 dB HL.

    · Bilateral fitting of the BONEBRIDGE is intended for patients having a symmetrically conductive or mixed hearing loss. The difference between the left and right sides' BC thresholds should be less than 10 dB on average measured at 0.5. 1, 2. and 3 kHz, or less than15 dB at individual frequencies.

    · Patients who have profound sensorineural hearing loss in one ear and normal hearing in the opposite ear (i.e., singlesided deafness or "SSD"). The pure tone average air conduction hearing thresholds of the hearing ear should be better than or equal to 20 dB HL (measured at0.5, 1, 2, and 3 kHz).

    · The BONEBRIDGE for SSD is also indicated for any patient who is indicated for an air-conduction contralateral routing of signals (AC CROS) hearing aid, but who for some reason cannot or will not use an AC CROS.

    · Prior to receiving the device, it is recommended that an individual have experience with appropriately fit air conduction or bone conduction hearing aids.

    Device Description

    BONEBRIDGE augments hearing by providing acoustic input to the inner ear via bone conduction. BONEBRIDGE consists of the following components: The Bone Conduction Implant (BCI) and the externally worn audio processor.

    The BCI 601 implant is provided in an implant kit together with two templates to determine optimal implant placement, one drill bit, two regular cortical titanium screws (gold surface) and one emergency screw (blue surface).

    All devices are shipped in one sterile tray and are for single-use only.

    The Bone Conduction Implant (BCI) is the implantable part of BONEBRIDGE and can only be used together with compatible MED-EL external components. The device is an osseointegrated bone conduction implant system, intended to provide a level of useful sound perception for individuals with conductive and mixed hearing loss, as well as those suffering from single-sided deafness. The BCI is surgically implanted into the mastoid bone.

    The BCI 601 has two main sections, the coil section and the transducer section.

    The BCl 601 consists of a magnet surrounded by the receiver coil, the electronics (demodulator), the transition and the Bone Conduction - Floating Mass Transducer (BC-FMT). The BCI 601 is activated by placing the external audio processor over the magnet of the BCI 601. The signal and the energy to drive the BC-FMT are transferred via an inductive link to the internal coil, processed by the demodulator and then relayed to the BC-FMT. The BC-FMT transduces the signal into mechanical vibrations, which are conducted to the mastoid bone via the cortical titanium screws. These vibrations stimulate the auditory system through the bone conduction pathway to allow the patient to hear.

    AI/ML Overview

    The provided text is a 510(k) summary for the MED-EL BONEBRIDGE device. This document primarily focuses on obtaining clearance for labeling updates regarding Electromagnetic Compatibility (EMC) and Magnetic Resonance Imaging (MRI) compatibility, rather than presenting a performance study for the device's primary function as a hearing system, or an AI-based system.

    Therefore, much of the requested information about acceptance criteria, efficacy studies, sample sizes, expert ground truth, and AI specifics are not available in this document. The document states that "No changes have been made to the devices themselves. Only the product labelling is affected." and the updates "do not affect the device intended use, fundamental operating principles or functional characteristics." This implies that the performance related to hearing augmentation was presumed to be established by previous clearances (DEN170009).

    Here's what can be extracted from the document:

    1. A table of acceptance criteria and the reported device performance

    The document does not provide a table of acceptance criteria for the hearing performance of the device, nor does it report the device's clinical performance in that regard. It focuses on the safety aspects related to EMC and MRI.

    Acceptance Criteria (related to labelling update)Reported Device Performance (related to labelling update)
    Electromagnetic Compatibility (EMC): Device meets established specifications for EMC."Electromagnetic compatibility testing" was conducted. "The collective results of the non-clinical testing demonstrate that BONEBRIDGE meets the established specifications to ensure consistent and safe performance for its intended use." (Specific numerical criteria or detailed results are not provided).
    Magnetic Resonance Imaging (MRI) Compatibility: BCI 601 implant is MR conditional at 1.5T."MRI compatibility testing" was conducted. The labelling update is "to label the BCI 601 implant as MR conditional at 1.5T." (Specific numerical criteria or detailed results are not provided).

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Test Set Sample Size: Not applicable. The document describes "bench testing" for EMC and MRI compatibility, not a clinical test set of patients or data in the typical sense for evaluating clinical performance. These tests are conducted on the device itself.
    • Data Provenance: Not applicable for clinical data. The tests are non-clinical bench tests. The document does not specify the location where these bench tests were conducted.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    Not applicable. Ground truth for EMC and MRI compatibility is established through standardized testing protocols (e.g., ISO, IEC standards) and engineering evaluations, not typically by clinical experts in the same way as, for example, image interpretation.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable. This concept is relevant for studies involving human interpretation or clinical endpoints, which this document does not cover for the labeling update.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This device is not an AI-assisted diagnostic tool, and no MRMC study is mentioned or relevant to the reported labeling update.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This device is not an algorithm, but an implantable hearing system.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    For the EMC and MRI compatibility bench tests, the "ground truth" would be objective measurements against established engineering and safety standards (e.g., electromagnetic interference limits, heating, artifact, or force limits within an MRI environment). The document does not explicitly detail these standards or the specific measurements. For the hearing performance (which is not evaluated in this document), the ground truth would typically be audiometric data and patient-reported outcomes.

    8. The sample size for the training set

    Not applicable. This device is not an AI algorithm that requires a training set.

    9. How the ground truth for the training set was established

    Not applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    DEN170009

    Validate with FDA (Live)

    Device Name
    Bonebridge
    Date Cleared
    2018-07-20

    (522 days)

    Product Code
    Regulation Number
    874.3340
    Type
    Direct
    Age Range
    All
    Reference & Predicate Devices
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The BONEBRIDGE bone conduction hearing implant system is intended for the following patients and indications:

    • Patients 12 years of age or older.
    • Patients who have a conductive or mixed hearing loss and still can benefit from sound amplification. The pure tone average (PTA) bone conduction (BC) threshold (measured at 0.5, 1, 2, and 3 kHz) should be better than or equal to 45 dB HL.
    • . Bilateral fitting of the BONEBRIDGE is intended for patients having a symmetrically conductive or mixed hearing loss. The difference between the left and right sides' BC thresholds should be less than 10 dB on average measured at 0.5, 1, 2, and 3 kHz, or less than 15 dB at individual frequencies.
    • Patients who have profound sensorineural hearing loss in one ear and normal hearing . in the opposite ear (i.e., single-sided deafness or "SSD"). The pure tone average air conduction hearing thresholds of the hearing ear should be better than or equal to 20 dB HL (measured at 0.5, 1, 2, and 3 kHz).
    • . The BONEBRIDGE for SSD is also indicated for any patient who is indicated for an air-conduction contralateral routing of signals (AC CROS) hearing aid, but who for some reason cannot or will not use an AC CROS.
    • . Prior to receiving the device, it is recommended that an individual have experience with appropriately fit air conduction or bone conduction hearing aids.
    Device Description

    The BONEBRIDGE consists of a Bone Conduction Implant that is surgically implanted in the mastoid bone and an external Audio Processor that is held in place on the patient's scalp by magnetic attraction between the implant and the Audio Processor (Figure 1).

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and the study data provided for the BONEBRIDGE™ System:

    The BONEBRIDGE™ System did not undergo a study to prove meeting "acceptance criteria" in the traditional sense of a classification algorithm with performance metrics like sensitivity, specificity, or AUC. Instead, it underwent a series of non-clinical (bench) and clinical studies to demonstrate its safety and effectiveness for its intended use as an active implantable bone conduction hearing system.

    The acceptance criteria are therefore defined by the successful demonstration of:

    • Biocompatibility of all components.
    • Sterilization and Shelf Life validation.
    • Electrical Safety and Electromagnetic Compatibility (EMC), including wireless compatibility.
    • Software (SYMFIT) verification and validation at a "Minor" Level of Concern.
    • Performance Testing (Bench) for the Audio Processor (SAMBA BB) and the Bone Conduction Implant (BCI 601) and surgical tools.
    • Clinical Effectiveness for conductive/mixed hearing loss and single-sided deafness.
    • Clinical Safety in terms of adverse events and maintenance of bone conduction thresholds.

    1. Table of Acceptance Criteria and Reported Device Performance

    Given the nature of the device, the "acceptance criteria" and "reported device performance" are largely based on meeting pre-defined thresholds and "passing" various tests to demonstrate safety and functional specifications.

    CategoryAcceptance Criteria (Design Requirement/Objective)Reported Device Performance (Result)
    BiocompatibilityAll patient-contacting components to be biocompatible per ISO 10993 standards.All components (SAMBA BB, BCI 601, BCI Lifts, Surgical Tools) passed all specified biocompatibility tests (Cytotoxicity, Sensitization, Irritation, Systemic Toxicity, Implantation, Genotoxicity, Subchronic Toxicity, Carcinogenicity, Pyrogenicity, Exhaustive Extraction, Particulate Matter).
    Sterilization & Shelf LifeSterilization validation per AAMI/ANSI/ISO 11135:2014; Shelf life validation for sterility and integrity per ISO 11607-1:2006.BCI 601, surgical tools, and BCI Lifts/Sizer Kit sterilization validated (EO sterilization, overkill approach). Packaging of sterile components validated for shelf life, sterility, and integrity. SAMBA BB is non-sterile.
    Electrical Safety & EMCMeet IEC 60601-1-2 EMC standards, ANSI C63.19 wireless compatibility, electrical safety per IEC 60601-1, leakage current/voltage difference.All acceptance criteria were met for EMC (with SAMBA BB), wireless compatibility, and electrical safety (BCI 601 and SAMBA BB). Minor reported issue of "parasitic demodulation" mitigated by labeling instructions.
    MR CompatibilityN/A (Device is identified as MR Unsafe, which is an accepted characteristic rather than a performance criterion)MR Unsafe.
    SoftwareSYMFIT software to be verified, validated, and hazard analyzed at "Minor" Level of Concern.Software description, hazard analysis, traceability, verification/validation, and revision history were addressed. SYMFIT is standalone and does not affect safety; failure only impacts programming.
    Bench Performance (SAMBA BB)Force Output: > Max Power Output (MPO) at specific frequencies (e.g., 90 dB μN at 500 Hz). Transmission Scheme: Difference between force output at 7mm and 4mm coupling distance ≤ 4 dB. Battery Lifetime: > 16 hours. Noise Floor: < 10 dB HL.All force output, transmission scheme, battery lifetime (>16 hours), and noise floor (<10 dB HL) criteria were passed. Additional tests (audiological performance, dual mic, physical characteristics, adapter compatibility, vibration, shock, drop, temperature, substance resistance, solar radiation, moisture ingress, atmospheric pressure, light, shipping, accessory & wireless compatibility, EMC/ESD, ERM, biocompatibility, usability) all passed.
    Bench Performance (BCI 601 & Surgical Tools)BCI Implant Performance: Signal quality (transducer distortion), output level limitation. Reliability: <5% failure rate after 10 years continuous use. Screw Torque/Force Stability: Max torque/force withstand capability. Bending: Functional after bending. Physical Characteristics: Dimensions, symmetry, coating. Simulated Surgical Implantation: Adequacy for safe implantation/fixation. External Pressure/Vibrations/Accelerations: Resistance to vibration, shock, dynamic impact, atmospheric pressure, pressurizing (swimming/diving), chronic implant movement, skull fracture (not adversely affected), 2.5J impact. Medical Treatment Compatibility: Compatibility with diagnostic ultrasound, surgical diathermy, X-ray/CT, radiation therapy/PET. Temperature Resistance: Operational (18-43°C) and storage (-20°C to 60°C).All performance objectives passed. Reliability testing (fatigue fracture, wire guard, adhesive joint, hermeticity, screw fracture, weld seams) showed no failures. Screw torque/force stability, bending, physical characteristics, and simulated implantation passed. All external pressure/vibration/acceleration tests passed, except for one BCI unit which showed a fine leak following a 3.5J impact (acceptance criterion was "no skull fractures were present", which was met). All medical treatment compatibility tests (ultrasound, diathermy, X-ray/CT, radiation/PET) passed. All temperature resistance tests passed.
    Bench Performance (BCI Lifts & Sizer Kit)Performance (Lifts): Performance, distortion, frequency response, linearity, torque/force stability. Mechanical Safety (Lifts): Withstand daily use forces. Usability (Lifts & Sizer Kit): Appropriate for intended use by surgeons during implantation.All BCI Lifts performance (including torque/force stability) and mechanical safety tests passed. Usability testing confirmed appropriate designs for intended use (surgeons implanted BCI 601 using Lifts and Sizer Kit).
    Clinical Effectiveness (CHL/MHL)Primary Endpoint: ≥15% improvement in word/sentence recognition (Freiburger Monosyllable Word recognition) from preoperative unaided to 12-month postoperative aided. Secondary Endpoints: Functional gain (≥28.9 dB PTA improvement 500-4000 Hz, unaided vs. aided); Speech Reception Threshold (SRT; OLSA) improvement.Primary Endpoint Met: Average 63.3% improvement in Freiburger Monosyllable Word recognition (p < 0.001). Secondary Endpoints Met: Mean 28.9 dB functional gain (p < 0.001); Mean 24.0 dB SRT improvement (OLSA) (p < 0.001). HDDS: 79.6% adults, 87.9% children showed increased satisfaction.
    Clinical Effectiveness (SSD)Primary Endpoint: N/A (The text for SSD explicitly states "no significant differences between aided vs. unaided speech recognition performance in scenarios 1 and 2" but then significant benefit was observed in scenario 3.) The primary effectiveness endpoint was generally stated as "met by all three studies". Specific SSD criterion: Significant benefit in speech presented to implanted ear with noise to contralateral ear (Scenario 3).Primary Endpoint Met (Overall): The text states "Overall, the primary effectiveness endpoint was met by all three studies". SSD Specific: Significant benefit of 1.56 dB SNR difference at 12 months for Scenario 3 (speech to implanted ear, noise to contralateral normal hearing ear). No detrimental effect in other scenarios. SSQ-B: 25.7% improvement (above 10% acceptance threshold).
    Clinical Safety (CHL/MHL & SSD)Primary Endpoint: Tabulate Adverse Events (AEs) and Serious Adverse Events (SAEs) through 12-month follow-up. Secondary Endpoint: ≤ mean 10 dB change in bone conduction thresholds (PTA 500-4000 Hz) from pre-op to post-op unaided.Primary Endpoint: 31 AEs, 1 SAE (unrelated to device/procedure) reported in BB001/BB002. 18 device/procedure-related AEs (including 2 SADEs; one excluded due to inclusion criteria violation). 2 procedure-related AEs in BB003. Overall AE rate for included subjects: 7.57% (5/66). SADE rate: 3.03% (2/66). Secondary Endpoint Met: No more than mean 10 dB change in BC thresholds (PTA). Mean pre-op BC: 16.03 dB HL vs. 12-month post-op BC: 17.03 dB HL.

    2. Sample Sizes and Data Provenance

    The document describes three clinical studies: BB001, BB002, and BB003.

    • BB001 (Prospective, single-arm, open-label, pre-market):
      • Sample Size: 24 subjects (12 adult, 12 pediatric) for 3 months post-implantation, with an unspecified number followed longer in BB002.
      • Data Provenance: Not specified, but likely international given the company's origin (Austria). Prospective.
    • BB002 (Post-market follow-up to BB001):
      • Sample Size: 53 subjects (45 adult, 8 pediatric). This appears to include 10 adults and 8 children from BB001, plus an additional 35 adults.
      • Data Provenance: Not specified, likely international. Prospective.
    • BB003 (Prospective, single-arm, open-label, post-market):
      • Sample Size: 13 adult patients with Single Sided Deafness (SSD).
      • Data Provenance: Not specified, likely international. Prospective.

    Test Set for Clinical Studies: The individuals participating in BB001, BB002, and BB003 serve as the test set for clinical performance. The total number of unique individuals across these studies for the most critical outcome assessments (e.g., 12-month data) is approximately 65 (BB001/BB002 + BB003, with some overlap from BB001 into BB002).

    Training Set: Not applicable in the context of this device. This is a medical device, not an AI/ML algorithm that requires a "training set" in the computational sense. The "training" for the device here refers to audiological fitting by healthcare professionals using software, not machine learning model training. The SYMFIT software mentioned explicitly states it "does not contain software" that controls the device's safety and is a "Minor Level of Concern" for failure.


    3. Number of Experts and Qualifications for Ground Truth of Test Set

    • Ground Truth: For this type of medical device, the "ground truth" for clinical effectiveness is primarily objective audiometric measurements (e.g., word recognition scores, functional gain, speech reception thresholds) and subjective patient-reported outcomes (satisfaction, improved hearing).
    • Experts: These measurements are performed by trained audiologists and healthcare professionals. The document does not specify the exact number of experts involved in data collection across all sites or their specific qualifications (e.g., "audiologist with X years of experience"). However, audiometric testing and clinical assessments are standard procedures performed by qualified professionals in the field of audiology and otolaryngology.

    4. Adjudication Method for the Test Set

    The document does not describe a formal "adjudication method" in the context of an expert panel reviewing test results for correctness. Clinical trial data, especially objective audiometric measurements, is typically collected according to a strict protocol on validated equipment and analyzed statistically. Adverse events are reported and classified by the investigators and potentially reviewed by a central safety committee or regulatory body, but a specific "adjudication method" for the test results in the way it might be used for diagnostic image interpretation is not mentioned or typically applicable for this type of device.


    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    No, a Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not done.
    MRMC studies are typically used for diagnostic devices, especially those involving image interpretation where multiple human readers assess cases. This device is a hearing prosthesis, and its effectiveness is measured by direct physiological and perceptual improvements in hearing, rather than by interpreting data generated by a separate diagnostic process.

    The "comparison" in the clinical studies is between the patient's preoperative unaided condition and their postoperative aided condition with the BONEBRIDGE system. There is no "human reader" involved in assessing the device's output in the way an MRMC study would imply.


    6. Standalone (Algorithm Only) Performance

    Yes, "standalone" performance testing was extensively done, but it's not "algorithm only" in the sense of AI. This device consists of hardware and associated audiological software for programming.

    • The bench testing for the SAMBA BB Audio Processor and the BCI 601 implant represents the standalone performance of the physical components. These tests evaluate the device's physical, electrical, and audiological specifications in isolation or in a controlled system setup (e.g., force output, battery life, noise floor, reliability, mechanical stability, compatibility tests).
    • The SYMFIT software itself is described as standalone computer software that does not affect the safety of the BONEBRIDGE system, and a failure could only result in inability to program the audio processor, indicating its "standalone" role in programming rather than real-time device operation.

    So, while not an "algorithm-only" performance in the AI sense, the physical device's performance was rigorously evaluated independently of human interaction during its core operation, which is then integrated via professional fitting.


    7. Type of Ground Truth Used

    For the clinical studies:

    • Objective Measures: The primary ground truth for effectiveness was derived from objective audiometric data. This includes:
      • Freiburger Monosyllable Word recognition scores.
      • Pure Tone Average (PTA) thresholds (functional gain).
      • Speech Reception Threshold (SRT) using the Oldenburger Satztest (OLSA).
      • Signal-to-Noise Ratio (SNR) for SSD patients.
    • Subjective Measures (Patient-Reported Outcomes): Additional ground truth came from patient-reported outcomes, specifically satisfaction and perceived benefits measured through:
      • Hearing Device Satisfaction Scale (HDSS) questionnaires.
      • Speech Spatial Qualities-Benefit Questionnaire (SSQ-B).
    • Safety Measures: For safety, the ground truth was derived from clinical observation and reporting of Adverse Events (AEs) and Serious Adverse Events (SAEs), as well as objective measures like changes in bone conduction thresholds at audiometric frequencies.

    8. Sample Size for the Training Set

    As mentioned above, this is a medical device, not an AI/ML algorithm that requires a "training set." Therefore, this question is not applicable in the context of the provided information.


    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there is no "training set" for an AI/ML algorithm. The "training" for the device (audiological fitting) is done by qualified healthcare professionals based on established audiometric principles and the patient's individual hearing profile.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1