Henan Yadu Level 4 Surgical Gown (Reinforced) are sterile, single-use surgical apparel intended to be used by operating room personnel during surgical operations and other invasive examinations to provide a liquid and microbial barrier for patients and medical staff.
These products meet the Level 4 liquid barrier performance requirements of ANSI/AAMI PB70:2022 "Liquid barrier performance and classification of protective apparel and drapes intended for use in health care facilities."
Henan Yadu Level 4 Surgical Gowns (Reinforced) are sterile, single-use surgical apparel intended to be worn by healthcare professionals during surgical procedures to provide barrier protection against the transfer of microorganisms, body fluids, and particulate matter in critical surgical zones for both patients and healthcare personnel.
These products meet the Level 4 liquid barrier performance requirements of ANSI/AAMI PB70:2022 "Liquid barrier performance and classification of protective apparel and drapes intended for use in health care facilities.
Gowns have six different sizes: Small (S), Medium (M), Large (L), Extra Large (XL), Extra Extra Large (XXL), Extra extra extra Large (XXXL).
N/A
Ask a specific question about this device
(280 days)
Level 3 Surgical Gown (Standard & Reinforced) are sterile, single-use surgical apparel intended to be worn by healthcare professionals during surgical procedures to provide barrier protection against the transfer of microorganisms, body fluids, and particulate matter in critical surgical zones for both patients and healthcare personnel.
The products meet the respective liquid barrier performance requirements for Level 3 as specified in ANSI/AAMI PB70:2022 "Liquid barrier performance and classification of protective apparel and drapes intended for use in health care facilities".
Surgical Gowns are class II medical devices under the FDA product code FYA, General & Plastic Surgery Panel, and Regulation 21 CFR 878.4040. The subject surgical gowns are single use, disposable and provided sterile. They are available as Standard or Reinforced at Critical areas of the gown to increase its resistance to fluid penetration. The gowns are designed for short to medium length procedures and procedures where there is moderate risk (AAMI PB70 level 3).
The subject gowns are single-use and provided sterile (Ethylene Oxide sterilization). The subject gowns provide barrier protection against the transfer of microorganisms, body fluids, and particulate matter in critical zones of the gowns for both patients and healthcare personnel.
N/A
Ask a specific question about this device
(243 days)
The Medi Lift Essential Eye Mask is intended for facial stimulation and indicated for over-the-counter cosmetic use.
The Medi Lift Essential Eye Mask ("Medi Lift Eye") is composed of a mask made of silicone rubber which is worn on the upper part of the user's face, and covers the upper cheek and the periocular region outside the orbital rim. The mask contains two controllers with electrodes, which are attached to the mask. These controllers and electrodes deliver electrical pulses to stimulate facial muscles. The controllers are operated independently by pressing buttons on each controller. The mask also contains a heater to warm the upper cheek area for user relaxation, not for a medical purpose. The stimulation and heating functions are provided in separate modes and cannot be used simultaneously. The controllers attached to the mask contain two charging pins which allow for the built-in Lithium-ion battery that powers the device to be charged using a USB charging cable that is provided as part of the device. The device is not operated during charging.
N/A
Ask a specific question about this device
(205 days)
The XC11 ICE Box Ultrasound System is intended for intra-cardiac and intra-luminal ultrasound imaging when operated with the XC11 ICE Catheter and XC11 ICE System Handle.
The XC11 ICE Catheter is intended for intra-cardiac and intra-luminal visualization of cardiac and great vessel anatomy and physiology, as well as visualization of other devices in the heart of adult and pediatric patients. The catheter is intended for imaging guidance only, not treatment delivery, during cardiac interventional percutaneous procedures.
The XC11 ICE Catheter is for use with Yorlabs XC11 ICE System Handle only.
The XC11 ICE System, USA is a fully integrated imaging platform designed for wireless communications and a compact footprint. It provides precise, real-time visualization of intracardiac anatomy and devices positioned within the heart.
The System is comprised of two main components:
XC11 ICE Catheter (2D), USA
A 9F, single-use, sterile device capable of real-time 2D side-view imaging for intracardiac and intraluminal ultrasound in adult and pediatric patients. The catheter features easy steering maneuverability via deflection and rotation, along with on-handle imaging controls for enhanced usability.
XC11 ICE Box Ultrasound System, USA
This unit houses the image data acquisition and computer modules for image display and includes a connector for interfacing with the XC11 ICE System Handle. The XC11 ICE Tablet with a touchscreen interface, enables technicians to control the system software efficiently.
N/A
Ask a specific question about this device
(273 days)
The Pure Plus UV Aspheric (Otufilcon A) Silicone Soft (hydrophilic) Contact Lens for Daily Wear and Pure Plus UV Aspheric (Otufilcon A) 1-Day Silicone Soft (hydrophilic) Contact Lens are indicated for the correction of refractive ametropia (myopia or hyperopia) in aphakic and not-aphakic persons with non-diseased eyes. The lens may be worn by person who exhibit astigmatism of 2.00 diopters or less that does not interfere with visual acuity. The eye care professionals may prescribe the lens for single use daily disposable or reusable daily wear in a Frequent Replacement Program.
DISPOSABLE WEAR:
When prescribed for Disposable Wear, the Pure Plus UV Aspheric (Otufilcon A) 1-Day Silicone Soft (hydrophilic) Contact Lens is to be discarded after each removal.
FREQUENT/PLANNED REPLACEMENT WEAR:
When prescribed for Frequent/Planned Replacement Wear, the Pure Plus UV Aspheric (Otufilcon A) Silicone Soft (hydrophilic) Contact Lens for Daily Wear should be disinfected using a chemical or hydrogen peroxide disinfecting system each time it is removed and should be discarded per the eye care practitioner's guidance.
The Pure Plus UV Aspheric (Otufilcon A) Silicone Soft (hydrophilic) Contact Lens for Daily Wear and Pure Plus UV Aspheric (Otufilcon A) 1-Day Silicone Soft (hydrophilic) Contact Lens are hydrophilic available with aspheric design manufactured by using Cast Molding method. The soft contact lens material, Otufilcon A, which is a copolymer of silicone-containing monomers and hydrophilic monomers, and has 44% water by weight.
These lenses contain UV blocker, a benzotriazole UV absorbing monomer to block UV radiation. Thus, the lens helps protect against the transmission of harmful UV radiation to the cornea and into the eye. The transmittance characteristics are less than 5 % in the UVB range of 280 nm to 315 nm and less than 50 % in the UVA range of 315 nm to 380 nm. The lenses are tinted from edge to edge for visibility purposes with the color additive. The lens is marked with wording "321" to help user better distinguish the correct side before inserting in eyes.
The lenses are available as aspheric lenses. Each finished lens is supplied in a plastic blister container with A) PMB Packaging Solution, or B) Cyanocobalamin Packaging Solution depends on customer's requirement.
N/A
Ask a specific question about this device
(252 days)
The SmartPilot YpsoMate NS-A2.25 is indicated for use with the compatible disposable autoinjector to capture and record injection information that provides feedback to the user.
The SmartPilot YpsoMate NS-A2.25 is an optional, battery operated, reusable device designed to be used together with a compatible autoinjector (a single use, needle based, pre-filled injection device for delivery of a drug or biologic into subcutaneous tissue). Figure 1 shows the SmartPilot YpsoMate NS-A2.25 with the paired autoinjector. The SmartPilot YpsoMate NS-A2.25 records device data, injection data and injection process status. The SmartPilot YpsoMate NS-A2.25 also provides guidance feedback to the user during the injection.
Note that the SmartPilot YpsoMate NS-A2.25 does not interfere with autoinjector function.
The provided 510(k) clearance letter details the substantial equivalence of the SmartPilot YpsoMate NS-A2.25 device to its predicate. While it lists various performance tests and standards met, it does not contain specific acceptance criteria values or detailed study results for metrics like sensitivity, specificity, or improvement in human reader performance. This document primarily focuses on demonstrating that the new device does not raise new questions of safety and effectiveness compared to the predicate, due to similar technological characteristics and adherence to relevant safety standards.
Therefore, many of the requested details about acceptance criteria, study design (sample size, data provenance, expert adjudication, MRMC studies), and ground truth establishment (especially for AI-driven performance) cannot be extracted directly from this regulatory document. The information primarily pertains to hardware, software, and usability testing.
However, based on the provided text, here's what can be inferred or stated about the device's acceptance criteria and proven performance:
Device: SmartPilot YpsoMate NS-A2.25
Indication for Use: The SmartPilot YpsoMate NS-A2.25 is indicated for use with the compatible disposable autoinjector to capture and record injection information that provides feedback to the user. Specifically compatible with Novartis/Sandoz Secukinumab (Cosentyx).
1. Table of Acceptance Criteria and Reported Device Performance
The document does not provide a table with quantitative acceptance criteria and reported performance values for metrics typically associated with AI/software performance (e.g., sensitivity, specificity, accuracy of data capture in a clinical context). Instead, it focuses on meeting established engineering, safety, and quality standards.
Here's a summary of the types of performance criteria implied by the successful completion of the listed tests:
| Acceptance Criterion (Implied) | Reported Device Performance (Achieved) | Supporting Test / Standard |
|---|---|---|
| Biocompatibility | Meets requirements for intact skin contact. | ISO 10993-1, -5, -10, -23 |
| Compatibility with Autoinjector | No negative impact on Essential Performance Requirements (EPRs) of compatible YpsoMate 2.25ml autoinjector. | ISO 11608-1:2022, ISO 11608-5:2022 (Influence Testing) |
| Basic Safety | Complies with general safety standards. | IEC 60601-1, Ed.3.2 2020-08 |
| Electromagnetic Compatibility (EMC) | Complies with EMC standards. | IEC 60601-1-2:2014 incl. AMD 1:2021 |
| Battery Safety | Complies with battery safety standards. | IEC 62133-2:2017 + A1:2021 |
| Wireless Communication (FCC) | Complies with FCC regulations for wireless devices. | FCC 47 CFR Part 15B, Part 15.225, Part 15.247 |
| Wireless Coexistence | Complies with standards for wireless coexistence. | IEEE ANSI USEMCSC C63.27-2021; AIM 7351731:2021 |
| Software Verification & Validation | Documentation level "enhanced," meets requirements for safety, cybersecurity, and interoperability. Software classified as B per ANSI AAMI ISO 62304:2006/A1:2016. | FDA Guidance on Software Functions, ANSI AAMI ISO 62304, Cybersecurity Testing, Interoperability testing |
| Electrical Hardware Functionality | BLE, NFC, inductance measurement, electromechanical switches, motion detection, temperature measurement all functional. | Electrical Hardware Requirements Testing |
| Indicator & Feedback Systems | Visual (LEDs with specified wavelength/intensity) and acoustic (adjustable sound volume) feedback systems are functional. | Electrical Hardware Requirements Testing |
| Durability & Lifetime | Meets specifications for switching cycles, 3-year storage, 2-year or 120-use operational lifespan, and operational tolerances. | Electrical Hardware Requirements Testing, Lifetime and Shelf Life Testing |
| Mechanical Integrity | Withstands use force, axial/twisting loads on inserted autoinjector, and maintains locking flag visibility. | Mechanical Testing |
| Shelf Life | Achieves a 3-year shelf life. | Shelf Life Testing |
| Human Factors/Usability | Complies with human factors engineering standards; formative and summative usability evaluations completed. | IEC 60601-1-6:2010/AMD2:2020, ANSI AAMI IEC 62366-1:2015 + AMD1 2020 |
| Transportation Safety | Maintains integrity after transportation simulation. | ASTM D4169-22 |
| Dose Accuracy (Influence) | Meets ISO 11608-1 requirements when evaluated with compatible YpsoMate AutoInjectors. This is related to the autoinjector's performance when used with the SmartPilot, not the SmartPilot's accuracy in measuring dose itself, as it states the SmartPilot "does not capture dosing information." | Influence Testing based on ISO 11608-1:2022 |
Note: The device's primary function is to "capture and record injection information that provides feedback to the user," and it "does not capture dosing information" or "electronically controlled dosing." Therefore, criteria related to dosing volume accuracy or AI interpretation of medical images/signals for diagnosis are not applicable to this device. The focus is on the accurate capture of event data (injection start/end, result) and providing timely feedback, as well as general device safety and functionality.
2. Sample Size Used for the Test Set and Data Provenance
The document describes various types of tests (e.g., Biocompatibility, EMC, Software V&V, Mechanical, Lifetime, Human Factors), but does not specify the sample sizes used for each test dataset.
Data Provenance: The document does not explicitly state the country of origin for the data or whether the studies were retrospective or prospective. Given that Ypsomed AG is based in Switzerland and the testing references international and US standards, the testing likely involved a mix of internal validation, third-party lab testing, and possibly user studies in relevant regions. All tests described are part of preclinical (non-clinical) performance validation, making them inherently prospective for the purpose of demonstrating device function and safety prior to marketing.
3. Number of Experts and Qualifications for Ground Truth
The document does not mention the use of experts in the context of establishing ground truth for the device's functional performance, as it is not an AI-driven diagnostic or interpretative device that relies on human expert consensus for its output. Its performance is evaluated against engineering specifications and physical/software functional requirements. The "Human Factors" testing would involve users, but not necessarily "experts" adjudicating correctness in the sense of accuracy for a diagnostic task.
4. Adjudication Method for the Test Set
Not applicable. The device's performance is determined by meeting pre-defined engineering and regulatory standards and testing protocols, not by expert adjudication of its output, as it does not produce subjective or interpretative results like an AI diagnostic algorithm.
5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study
Not performed/applicable. An MRMC study is relevant for AI systems that assist human readers in tasks like image interpretation to demonstrate improved diagnostic accuracy. This device is an "Injection Data Capture Device" providing feedback and recording information; it does not involve human readers interpreting data that the device enhances.
6. Standalone (Algorithm Only) Performance
While the device has software and algorithms to detect injection events and provide feedback, the document does not report "standalone" performance metrics in the way an AI diagnostic algorithm would (e.g., sensitivity, specificity). Its performance is demonstrated through the verification and validation of its hardware and software components (e.g., ability to detect spring position, successful data transfer, correct LED/audible feedback). The "Influence Testing" evaluates its performance in conjunction with the autoinjector, proving it does not negatively interfere.
7. Type of Ground Truth Used
The ground truth for the verification and validation of this device is engineering specifications, physical measurements, and adherence to established regulatory and industry standards. For example:
- Biocompatibility: Measured against established thresholds for cytotoxicity, sensitization, and irritation.
- EMC/Safety: Compliance with current versions of IEC standards.
- Software V&V: Compliance with software lifecycle processes and cybersecurity standards, and correct execution of defined functions (e.g., data recording, feedback activation).
- Mechanical/Lifetime: Physical measurements (e.g., activation force, dimension checks), cycle counts, and functional checks after simulated use/aging.
- Human Factors: User performance and subjective feedback against usability goals.
There is no "expert consensus," "pathology," or "outcomes data" ground truth in the context of its direct function (data capture and feedback).
8. Sample Size for the Training Set
Not applicable. This device is not an AI/machine learning system that requires a "training set" in the conventional sense (i.e., for learning to perform a complex, data-driven task like image recognition or diagnosis). Its functionality is based on programmed logic and sensor readings, not statistical learning from a large dataset.
9. How the Ground Truth for the Training Set Was Established
Not applicable, as there is no "training set" for the type of device described. Input signals (e.g., from the inductive sensor about spring position) are processed based on predefined engineering parameters and logical rules to determine injection status, not learned from a dataset.
Ask a specific question about this device
(29 days)
Hasla is intended to produce two-dimensional digital x-ray images including panoramic and cephalometric image, and three-dimensional digital x-ray images of the dental, oral, maxillofacial region, at the direction of healthcare professionals as diagnostic support for adult and pediatric patients.
This device is not intended for use on patients less than approximately 21 kg (46 lb) in weight and 113 cm (44.5 in) in height; these height and weight measurements approximately correspond to that of an average 5 year old.
The product (Dental CBCT X-ray System, Model: Hasla) uses cone-beam computed tomography (CBCT) through X-ray cone-beam, panoramic radiography, cephalometric radiography to produce images of the dental, oral and maxillofacial areas to provides diagnostic details for the medical facilities. This product consists of Frame, X-ray generator (including Integrated X-ray source tube head, X-ray tube, Collimator), Image receptor and Image processing system (including Computer, Monitor, and Software workstation).
The provided FDA 510(k) clearance letter and summary for the Yian Medical Technology (Haining) Co., Ltd. Dental CBCT X-ray System (Model: Hasla) indicate that this is a Special 510(k) for a device modification. This means the company is asserting that the modified device is substantially equivalent to their own previously cleared predicate device (Dental Cone-beam Computed Tomography, Model: iDT901X1, K232710) and that the modifications do not raise any new safety or effectiveness concerns.
Therefore, the submission relies on the previous clearance and asserts that the current device meets the same acceptance criteria as the predicate without requiring new comprehensive studies to prove that from scratch. Instead, it demonstrates that the modifications themselves do not negatively impact the performance, safety, or efficacy previously established.
Given this context, here's a breakdown of the information requested. It's important to understand that the document does not report on a new study for the current device to explicitly prove it meets acceptance criteria with new data. Instead, it leverages the prior clearance through a demonstration of equivalence.
Acceptance Criteria and Device Performance (as related to the predicate device and the claim of equivalence)
The document states: "The subject device and the predicate device are equivalent in the model name, same in the indications for use, patient population, use environment, software functions, and software level of documentation, performance characteristics and technical specification." It further specifies that "Any difference between the predicate device and the subject device have no impact on safety or efficacy of the subject device and do not raise any new potential or increased safety risks."
Therefore, the "acceptance criteria" for the current device are implicitly met by demonstrating that its performance and safety characteristics are unchanged from the predicate device, which had previously met its own acceptance criteria during its clearance process (K232710).
The summary provides a detailed comparison table (Table 1) between the subject device (Hasla) and the predicate device (iDT901X1). Essentially, all listed specifications and performance characteristics are presented as identical between the two.
Table 1: Acceptance Criteria (Implied from Predicate Equivalence) and Reported Device Performance
| Feature/Acceptance Criteria Category (Implied) | Reported Performance (Subject Device is equivalent to Predicate) |
|---|---|
| Indications for Use | "Hasla is intended to produce two-dimensional digital x-ray images including panoramic and cephalometric image, and three-dimensional digital x-ray images of the dental, oral, maxillofacial region, at the direction of healthcare professionals as diagnostic support for adult and pediatric patients. This device is not intended for use on patients less than approximately 21 kg (46 lb) in weight and 113 cm (44.5 in) in height..." |
| Target Population | For patients 6 years and older |
| Anatomical Site | The dental, oral, maxillofacial region |
| Users | Health care professionals |
| Patient Contact Material | Meet ISO 10993 series standard (Non-sterile) |
| Tube Voltage | 60kV~120kV |
| Tube Current | 1 mA~20 mA |
| Nominal Focal Spot Size | 0.5 |
| Pulse Exposure function | Yes |
| Power | Frequency: 50/60Hz, Voltage: 110-120VAC, Power: 3.0KVA |
| Detector | FPD(TFT), material: CsI |
| Pixel Size | 200µm x 200µm (With binning) (CT, Cephalometric); 100µm x 100µm(Without binning)(CT, Panoramic) |
| Pixel Number | 15041248 (With binning) (CT, Cephalometric); 8002496 (Without binning) (CT); 300865 (Without binning) (Panoramic); 15041248 (With binning) (Cephalometric) |
| Size of Area Receiving X-ray | 300.8mm x 249.6mm (CT, CEPH); 80mm x 249.6mm (CT); 300.8mm x 6.5mm (PANO) |
| Spatial Resolution | 5lp/mm |
| Number of Bits | 16bits |
| SID/SOD | SID: 750mm/490mm |
| Dimension (WxDxH) | Max.overall dimension 1300mm1272mm2365mm |
| Weight | 233kg±5kg |
| Imaging Mode | CBCT, PANO, CEPH |
| Panoramic Scan Performance (Scan Time) | 15sec |
| Cephalometric Radiography (Scan Time) | 2.3sec |
| CT Scan Time | 22sec |
| CT FOV (Voxel Size) | Diameter 230 mm x 180mm (0.45mm); Diameter 150 mm x 120mm (0.29mm); Diameter 80 mm x 80mm (0.15mm); Diameter 50 mm x 50mm (0.097mm); Diameter 50 mm x 50mm (0.071mm) |
| Software functions | Image acquisition, data management, image display, image processing, System Settings |
| Software level of documentation | Basic Documentation Level |
| Compliance with Electrical Safety Standards | ANSI/AAMI ES60601-1, IEC 60601-1, IEC60601-1 Edition 3.2 2020-08, ANSI/AAMI ES: 60601-1:2005/A2:2010/AMD2:2021 |
| Compliance with Electromagnetic Compatibility Standards | IEC 60601-1-2 |
| Compliance with Radiation Safety Standards | IEC 60601-1-3 |
| Compliance with Electrical Equipment Usability Safety | IEC 60601-1-6 |
| Compliance with Usability Engineering Standard | IEC 62366 |
| Compliance with Software Lifecycle Process Standard | IEC 62304 |
| Compliance with Essential performance of dental extra-oral X-ray equipment Standard | IEC 60601-2-63 |
| Compliance with Acceptance tests of Imaging performance of computed tomography X-ray equipment Standard | IEC 61223-3-4; IEC 61223-3-7 |
| Compliance with Laser Safety standard | IEC 60825-1 |
| Compliance with Risk Management Standard | ISO 14971 |
| Compliance with DICOM Standard | ISO 12052:2017 |
| Compliance with Biocompatibility Standard | ISO 10993-1, ISO 10993-5, ISO 10993-10, ISO 10993-23 |
Study Details (Based on the provided document for the current 510(k) submission)
It's crucial to reiterate that this is a Special 510(k). The document explicitly states: "The modifications of the device have no impact on the product's design, working principle, software function, software documentation level, performance characteristic and technical specification indication for use, patient population, environment of use, user needs, thus no impact on the previously conducted Bench Testing and validation. No new bench testing or validation was needed. The previously conducted and submitted verification and validation test results are still valid for the modified device..."
-
Sample size used for the test set and the data provenance:
- Test Set Sample Size: Not applicable/Not specified as new data. The submission relies on the testing of the predicate device (K232710) and general compliance with standards.
- Data Provenance: Not applicable/Not specified, as no new clinical or standalone performance studies were explicitly conducted for this submission beyond bench testing to confirm compliance with recognized standards. The submitter is Yian Medical Technology (Haining) Co., Ltd. in China.
-
Number of experts used to establish the ground truth for the test set and the qualifications of those experts:
- Not applicable. This submission does not detail a study involving expert readers or ground truth establishment, as it's a Special 510(k) relying on equivalence to a previously cleared device.
-
Adjudication method (e.g., 2+1, 3+1, none) for the test set:
- Not applicable. No such study or adjudication method is described.
-
If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:
- No. This device is a Dental CBCT X-ray System, which is an imaging acquisition device, not an AI-based diagnostic tool for human reader interpretation improvement. The document explicitly states: "The subject of this premarket submission, did not require clinical studies to support substantial equivalence."
-
If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:
- No. This device is an imaging system, not a standalone algorithm. The clearance is based on the device's ability to produce images compliant with established standards, not on an algorithm's diagnostic performance. The document explicitly states: "The subject of this premarket submission, did not require clinical studies to support substantial equivalence." The bench testing cited ("Bench Testing Summary") confirms the physical and technical specifications against standards (e.g., spatial resolution, focal spot size, etc.), which are standalone performance characteristics of the device (hardware/software combined for image generation), but not a "standalone algorithm" in the typical sense of AI performance.
-
The type of ground truth used (expert consensus, pathology, outcomes data, etc.):
- Not applicable. No new clinical studies requiring external ground truth were conducted for this Special 510(k). The evaluation revolves around compliance with engineering and radiation safety standards, and performance characteristics (like spatial resolution, scan time) derived from bench testing using phantoms or calibrated equipment.
-
The sample size for the training set:
- Not applicable. This is not an AI algorithm requiring a training set in the conventional sense. The "software functions" mentioned are for image acquisition, data management, display, processing, and system settings, which are intrinsic to the operation of the imaging device itself.
-
How the ground truth for the training set was established:
- Not applicable, as there is no specific training set described for an algorithm in this context.
Ask a specific question about this device
(269 days)
The Sterilization Pouch and Roll are intended to provide health care workers with an effective method to enclose devices intended for steam sterilization. The recommended sterilization cycle is as follows:
• Pre-vacuum Steam: 4 minutes at 132°C (270°F); 30 minutes dry time.
The sterilization pouch and roll are made with medical grade paper and medical compound film. The sterilization pouch and roll maintain the sterility of the enclosed devices for up to 6 months post steam sterilization. The pouch's external chemical ink indicators are designed to indicate to the user that the pouch has undergone a steam sterilization process. The steam sterilization indicator color will change from blue before sterilization to dark grey after sterilization.
The subject Sterilization Pouch and Roll device has five types:
(1) Self-sealing sterilization pouches:
These pouches are made from a medical grade plastic film that is heat sealed on three sides. The fourth side has an adhesive strip that is used to seal the pouch. Release paper used in the pouch is a laminated sheet with composing structure of PE/paper/PE. It is a strip to cover the adhesive area and is released before seal the pouch. The medical grade paper conforms to recognized material standards and can be sterilized by steam. The Process Indicators Ink printed on the medical grade paper will exhibit a color change after the pouch is exposed to steam.
(2) Sterilization pouches, Flat:
These pouches have the same components with the Self-sealing sterilization pouches, except the fourth side is left opened instead of an adhesive strip and will be heat-sealed when using.
(3) Sterilization pouches, Gusseted:
These pouches are the same with the Sterilization pouches, flat, except that the plastic film is folded on both longest sides instead of flat. This design is convenient to enclose the medical devices with certain height.
(4) Sterilization rolls, Flat:
These rolls are made from a medical grade paper and plastic film that are heat sealed on opposite two sides. It will be cut into the suitable length and the opened sides will be heat-sealed. The indicators printed on the medical grade paper are the same with the self-sealing sterilization pouches.
(5) Sterilization rolls, Gusseted:
These rolls are the same with the flat sterilization roll, except that the plastic film is folded on both longest sides instead of flat. This design is convenient to enclose the medical devices with certain height.
The Sterilization pouch and roll is composed of medical grade paper (60g/m2) and medical compound film (52μm), it is intended to be used to contain medical devices to be terminally sterilized by the Steam sterilization process. The recommended sterilization cycle parameters are:
Pre-vacuum Steam: 4 minutes at 132°C (270°F); 30 minutes dry time.
The medical devices are inserted into the Pouch/Roll, sealed, and then sterilized for the Steam Sterilization Process. The heat-sealed pouch/roll are heat sealed prior to sterilization processing. After completion of the sterilization process, the Pouch/Roll maintain sterility of the enclosed medical devices until the seal is opened.
The device is intended to allow sterilization of enclosed devices and to maintain sterility of the enclosed devices until used up to 6 months post sterilization. The shelf life of the device is 3 months.
The Pouch/Roll is printed with a chemical indicator bar that changes from Blue to Dark grey when exposed to steam during the sterilization process. The steam chemical Indicator offers an addition way to verity processing in the sterilization cycle. The endpoint stability of the chemical indicator color change to dark grey is 3 months. The chemical Indicator should be used in addition to, not in place of, the biological indicator. The steam chemical indicator does not signify sterilization; it only indicates that the indicator has been exposed to steam.
The provided FDA 510(k) clearance letter and summary describe a Sterilization Pouch and Roll device, which is a Class II medical device. This is NOT an AI/ML device. Therefore, the questions related to AI/ML device performance metrics, such as effect size of human readers improving with AI, standalone algorithm performance, number of experts for ground truth, and training set information, are not applicable.
Here's a breakdown of the acceptance criteria and the study that proves the device meets them, based on the provided document:
1. Table of Acceptance Criteria and Reported Device Performance
| Test Item | Acceptance Criteria (Endpoint) | Reported Device Performance (Results) |
|---|---|---|
| Sterilant Penetration/Drying Time | - Meets the requirement of SAL 10-6- The weight difference before sterilization and after drying shall not exceed 3% | Pass |
| Biocompatibility - Cytotoxicity | Non-cytotoxic | Under conditions of the study, did not show potential toxicity to L-929 cells. Pass |
| Biocompatibility - Irritation | Non-irritating | Under the conditions of the study, not an irritant. Pass |
| Biocompatibility - Sensitization | Non-sensitizing | Under conditions of the study, not a sensitizer. Pass |
| Package Appearance | The appearance of the sterilization pouch is clean, intact, and sealed on all four sides. | Pass |
| Thickness | 52 ± 12% μm | Pass |
| Tensile Strength of Paper | MD ≥ 4.4 KN/mCD ≥ 2.2 KN/m | Pass |
| Bursting Test | Burst value > 3 Kpa or No Burst | Pass |
| Dye Penetration Test | The dye solution is no any leakage across the seal width of sterile barrier system. (No Infiltration) | Pass |
| Seal Strength Test | ≥ 2.5 N/15mm | Pass |
| Vacuum Leakage Test | No water can penetrate the sterilization pouch. | Pass |
| Microbial Barrier | 0 CFU No growth | Pass |
| Chemical Indicator Functionality | Color of indicator changes from blue to dark grey after Steam sterilization | Pass |
| Chemical Indicator Shelf Life & Endpoint Stability | Shelf life: 3 monthsEndpoint stability: 3 months | Pass |
| Shelf Life (Product) | Shelf life: 3 months | Pass |
| Maintenance of Sterility | Maintains sterility of enclosed devices for up to 6 months post steam sterilization. (This is an indication from the "Indications for Use" and is generally supported by the package integrity and microbial barrier tests over time, often through accelerated aging studies). | The document states "The device is intended to allow sterilization of enclosed devices and to maintain sterility of the enclosed devices until used up to 6 months post sterilization." The "Maintenance of Sterility" is listed as a "Different" characteristic compared to the predicate (6 months vs. 3 years for EO and 6 months for Steam). The microbial barrier test is passed, supporting the general concept of sterility maintenance, but the specific validation for the 6-month claim is not detailed in the summary table. |
2. Sample Size Used for the Test Set and Data Provenance
The provided document details various performance tests such as sterilant penetration, biocompatibility, package integrity, and chemical indicator testing. However, it does not explicitly state the sample sizes used for each of these test sets. The tests are "bench testing" (non-clinical) and do not involve human subjects.
The data provenance is from non-clinical bench testing. The tests were performed to evaluate the performance and functionality of the device against a requirement specification. There is no mention of country of origin for the data or whether it was retrospective or prospective, as these terms are typically relevant for clinical studies or data collection in human populations.
3. Number of Experts and Qualifications for Ground Truth
Not applicable. This device is a physical sterilization pouch and roll, and its performance is evaluated through standardized laboratory and bench testing against established physical, chemical, and biological criteria, not by human expert interpretation of data or images. Ground truth is established by objective measurements and standardized test methods.
4. Adjudication Method for the Test Set
Not applicable. As described above, the evaluation relies on objective measurements and established standards rather than expert interpretation requiring adjudication.
5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done
No, a Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not done. This type of study is relevant for AI/ML devices where human performance with and without AI assistance is being compared. This document is for a physical sterilization product.
6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) was Done
Not applicable. This device is a physical product, not an algorithm or software. Therefore, there is no "standalone" algorithm performance to evaluate.
7. The Type of Ground Truth Used
The ground truth for this device's testing is based on:
- Standardized Test Methodologies and Acceptance Criteria: As outlined in the "Test Methodology" and "Acceptance Criteria or End Point" columns in Table 3 of the 510(k) summary. These include standards like ISO 17665-1, ISO 10993 series, ASTM F1886, ASTM F2251, ISO 1924-2, ASTM F1140, ASTM F1929, ASTM F88, ASTM D3078, DIN 58953-6, ISO 11140-1, and ASTM F1980.
- Physical and Chemical Measurement: For properties like thickness, tensile strength, burst strength, seal strength, and the color change of the chemical indicator.
- Microbiological Evaluation: For the microbial barrier test (e.g., 0 CFU No growth).
- Biocompatibility Testing: Evaluating potential toxicity, irritation, and sensitization in laboratory settings (e.g., L-929 cells).
- Sterilization Effectiveness: Meeting a specified Sterility Assurance Level (SAL 10-6).
8. The Sample Size for the Training Set
Not applicable. There is no AI/ML component described for this device, so there is no training set in the context of machine learning.
9. How the Ground Truth for the Training Set was Established
Not applicable, as there is no training set.