Search Filters

Search Results

Found 480 results

510(k) Data Aggregation

    K Number
    K260049

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2026-04-07

    (90 days)

    Product Code
    Regulation Number
    866.3173
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K260048

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2026-04-07

    (90 days)

    Product Code
    Regulation Number
    866.3310
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K260046

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2026-04-07

    (90 days)

    Product Code
    Regulation Number
    866.3173
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K260026

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2026-04-02

    (87 days)

    Product Code
    Regulation Number
    866.5270
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K253491

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2026-02-12

    (111 days)

    Product Code
    Regulation Number
    862.1600
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    cobas pro integrated solutions is an automated analyzer, intended for running qualitative, semiquantitative, and quantitative clinical chemistry and immunochemistry assays as well as ion-selective measurements.

    Glucose HK Gen.3 is an in vitro test for the quantitative determination of glucose in human serum, plasma, urine and CSF on cobas c systems. Glucose measurements are used in the diagnosis and treatment of carbohydrate metabolism disorders including diabetes mellitus, neonatal hypoglycemia, and idiopathic hypoglycemia, and pancreatic islet cell tumors.

    Methadone II (MDN2) is an in vitro diagnostic test for the qualitative and semiquantitative detection of methadone in human urine on cobas c systems at a cutoff concentration of 300 ng/mL. Semiquantitative test results may be obtained that permit laboratories to assess assay performance as part of a quality control program. Semiquantitative assays are intended to determine an appropriate dilution of the specimen for confirmation by a confirmatory method such as gas chromatography/mass spectrometry (GC-MS).

    Methadone II provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. GC-MS is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used.

    Device Description

    The cobas pro integrated solutions consists of a high throughput core unit (sample supply unit and sample buffer unit) and can be configured with different analytical units for immunology, clinical chemistry, and electrolyte testing. The cobas c 703 analytical unit being added to cobas pro integrated solutions is a new clinical chemistry analyzer intended for the in-vitro quantitative/qualitative determination of analytes in body fluids.

    Glucose is phosphorylated by hexokinase (HK) in the presence of adenosine triphosphate (ATP) and magnesium ions to produce glucose-6-phosphate (G-6-P) and adenosine diphosphate (ADP). Glucose-6-phosphate dehydrogenase (G-6-PDH) specifically oxidizes G-6-P to 6-phosphogluconate with the concurrent reduction of nicotinamide adenine dinucleotide (NAD) to nicotinamide adenine dinucleotide reduced (NADH). One micromole of NADH is produced for each micromole of glucose consumed. The NADH produced absorbs light at 340 nm and can be detected spectrophotometrically as an increased absorbance.

    The Methadone assay is based on the kinetic interaction of microparticles in a solution (KIMS) as measured by changes in light transmission. In the absence of sample drug, soluble drug conjugates bind to antibody-bound microparticles, causing the formation of particle aggregates. As the aggregation reaction proceeds in the absence of sample drug, the absorbance increases. When a urine sample contains the drug in question, this drug competes with the drug derivative conjugate for microparticle‑bound antibody. Antibody bound to sample drug is no longer available to promote particle aggregation, and subsequent particle lattice formation is inhibited. The presence of sample drug diminishes the increasing absorbance in proportion to the concentration of drug in the sample. Sample drug content is determined relative to the value obtained for a known cutoff concentration of drug.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K253490

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2026-02-12

    (111 days)

    Product Code
    Regulation Number
    862.1345
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    cobas pro integrated solutions is an automated analyzer, intended for running qualitative, semiquantitative, and quantitative clinical chemistry and immunochemistry assays as well as ion-selective measurements.

    Glucose HK Gen.3 is an in vitro test for the quantitative determination of glucose in human serum, plasma, urine and CSF on cobas c systems. Glucose measurements are used in the diagnosis and treatment of carbohydrate metabolism disorders including diabetes mellitus, neonatal hypoglycemia, and idiopathic hypoglycemia, and pancreatic islet cell tumors.

    Methadone II (MDN2) is an in vitro diagnostic test for the qualitative and semiquantitative detection of methadone in human urine on cobas c systems at a cutoff concentration of 300 ng/mL. Semiquantitative test results may be obtained that permit laboratories to assess assay performance as part of a quality control program. Semiquantitative assays are intended to determine an appropriate dilution of the specimen for confirmation by a confirmatory method such as gas chromatography/mass spectrometry (GC-MS).

    Methadone II provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. GC-MS is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used.

    Device Description

    cobas pro integrated solutions is an automated analyzer, intended for running qualitative, semiquantitative, and quantitative clinical chemistry and immunochemistry assays as well as ion-selective measurements.

    The cobas pro integrated solutions consists of a high throughput core unit (sample supply unit and sample buffer unit) and can be configured with different analytical units for immunology, clinical chemistry, and electrolyte testing. The cobas c 703 analytical unit being added to cobas pro integrated solutions is a new clinical chemistry analyzer intended for the in-vitro quantitative/qualitative determination of analytes in body fluids.

    Glucose is phosphorylated by hexokinase (HK) in the presence of adenosine triphosphate (ATP) and magnesium ions to produce glucose-6-phosphate (G-6-P) and adenosine diphosphate (ADP). Glucose-6-phosphate dehydrogenase (G-6-PDH) specifically oxidizes G-6-P to 6-phosphogluconate with the concurrent reduction of nicotinamide adenine dinucleotide (NAD) to nicotinamide adenine dinucleotide reduced (NADH). One micromole of NADH is produced for each micromole of glucose consumed. The NADH produced absorbs light at 340 nm and can be detected spectrophotometrically as an increased absorbance.

    The Methadone assay is based on the kinetic interaction of microparticles in a solution (KIMS) as measured by changes in light transmission. In the absence of sample drug, soluble drug conjugates bind to antibody-bound microparticles, causing the formation of particle aggregates. As the aggregation reaction proceeds in the absence of sample drug, the absorbance increases. When a urine sample contains the drug in question, this drug competes with the drug derivative conjugate for microparticle‑bound antibody. Antibody bound to sample drug is no longer available to promote particle aggregation, and subsequent particle lattice formation is inhibited. The presence of sample drug diminishes the increasing absorbance in proportion to the concentration of drug in the sample. Sample drug content is determined relative to the value obtained for a known cutoff concentration of drug.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K253839

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-12-17

    (16 days)

    Product Code
    Regulation Number
    866.3983
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Elecsys Anti-SARS-CoV-2 is an immunoassay intended for the in vitro qualitative detection of total antibodies to Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in human serum and Li-heparin, K2-EDTA and K3-EDTA plasma collected on or after 15 days post-symptom onset. The test is intended as an aid in identifying individuals with an adaptive immune response to SARS-CoV-2, indicating recent or prior infection.

    The electrochemiluminescence immunoassay "ECLIA" is intended for use on cobas e 601 immunoassay analyzer.

    Device Description

    Elecsys Anti-SARS-CoV-2 is a qualitative, serological, double-antigen sandwich principle immunoassay to be used on the cobas e 601 analyzer with an 18-minute test time. Results are determined automatically by the software by comparing the electrochemiluminescence signal obtained from the reaction product of the sample with the signal of the cutoff value previously obtained by calibration. The Elecsys Anti‑SARS‑CoV-2 assay uses a recombinant protein representing the nucleocapsid (N) antigen for the determination of antibodies against SARS‑CoV‑2.

    The reagent working solutions include: rackpack (kit placed on the analyzer)

    • M Streptavidin-coated microparticles (transparent cap), 1 bottle, 12 mL: Streptavidin-coated microparticles 0.72 mg/mL; preservative.
    • R1 SARS-CoV-2-Ag~biotin, (gray cap), 1 bottle, 16 mL: Biotinylated SARS‑CoV‑2‑specific recombinant antigen (E. coli) < 0.5 mg/L; HEPES^a) buffer 50 mmol/L, pH 7.7; preservative.
    • R2 SARS-CoV-2 Ag~Ru(bpy) (black cap), 1 bottle, 16 mL: SARS‑CoV‑2‑specific recombinant antigen labeled with ruthenium complex < 0.5 mg/L; HEPES^(b) buffer 50 mmol/L, pH 7.7; preservative.

    ^(a) HEPES = [4-(2-hydroxyethyl)-piperazine]-ethane sulfonic acid

    The Elecsys Anti-SARS-CoV-2 assay includes two liquid calibrators, which are packed with the test kit:

    • ACOV2 Cal1 Negative calibrator 1 (white cap), 2 bottles of 0.67 mL: Human serum, non-reactive for anti‑SARS‑CoV‑2 antibodies; buffer; preservative.
    • ACOV2 Cal2 Positive calibrator 2 (black cap), 2 bottles of 0.67 mL: Human serum, reactive for anti‑SARS‑CoV‑2 antibodies; buffer; preservative.
    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K253188

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-10-24

    (28 days)

    Product Code
    Regulation Number
    864.7750
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The CoaguChek XS Plus System is intended for use by professional healthcare providers for quantitative prothrombin time testing for the monitoring of warfarin therapy. The system uses fresh capillary or non-anticoagulated venous whole blood.

    Device Description

    The CoaguChek XS Plus system is a portable coagulation monitoring system to monitor prothrombin time (PT) in patients receiving oral anticoagulant therapy. The system uses the amperometric detection of thrombin in the blood sample. A test strip is used to determine a PT value from 8 µL of whole blood. Onboard quality control is available on every test strip and the system also features an optional external quality control material (CoaguChek XS PT Control).

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252163

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-10-08

    (90 days)

    Product Code
    Regulation Number
    866.5840
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Elecsys Phospho-Tau (181P) Plasma is an in vitro electrochemiluminescence immunoassay (ECLIA) intended for the measurement of the phosphorylated Tau 181 protein in human plasma on cobas e immunoassay analyzers.

    The Elecsys Phospho-Tau (181P) Plasma assay result is intended to be used as an aid in the initial assessment for Alzheimer's disease and other causes of cognitive decline in adult patients aged 55 years and older, presenting with signs, symptoms, or complaints of cognitive decline. The result should be interpreted in conjunction with other clinical information.

    A negative test result is consistent with a negative amyloid positron emission tomography (PET) scan result and reduced likelihood that a patient's cognitive impairment is due to amyloid pathology. These patients should be investigated for other causes of cognitive decline.

    A positive test result may not be consistent with a positive amyloid PET scan result. Patients with an initial positive result should be further investigated to determine whether the amyloid pathology can be a cause of cognitive impairment.

    Device Description

    In vitro electrochemiluminescence immunoassay (ECLIA) intended for the measurement of the phosphorylated Tau 181 protein (pTau181p) in human plasma.

    Elecsys Phospho-Tau (181P) Plasma utilizes a sandwich test principle and has a total duration time of 18 minutes.

    • 1st incubation: 30 µL of sample, biotinylated monoclonal antibody specific for phosphorylation at threonine 181, and a monoclonal tau-specific antibody labeled with a ruthenium complex^a) react to form a sandwich complex.
    • 2nd incubation: After addition of streptavidin-coated microparticles, the complex becomes bound to the solid phase via interaction of biotin and streptavidin.
    • The reaction mixture is aspirated into the measuring cell where the microparticles are magnetically captured onto the surface of the electrode. Unbound substances are then removed with ProCell II M. Application of a voltage to the electrode then induces chemiluminescent emission which is measured by a photomultiplier.
    • Results are determined via a calibration curve which is instrument-specifically generated by 2-point calibration and a master curve provided via the cobas link.
    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K242505

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-07-17

    (329 days)

    Product Code
    Regulation Number
    862.1205
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Immunoassay for the in vitro quantitative determination of cortisol in human urine. The determination of cortisol is used for the recognition and treatment of functional disorders of the adrenal gland.

    The electrochemiluminescence immunoassay "ECLIA" is intended for use on cobas e immunoassay analyzers.

    Device Description

    The Elecsys Cortisol III immunoassay employs a competitive test principle using a cortisol-specific biotinylated monoclonal antibody and a cortisol-derivative labeled with a ruthenium complex. The Elecsys Cortisol III immunoassay is intended for the in vitro quantitative determination of cortisol in human urine. The determination of cortisol is used for the recognition and treatment of functional disorders of the adrenal gland on the cobas e immunoassay analyzers.

    Results are determined via a calibration curve which is instrument-specifically generated by a two-point calibration and a master curve provided via the cobas link.

    The Elecsys Cortisol III immunoassay reagent Rack Pack comprises the following:

    M Streptavidin-coated microparticles (transparent cap), 1 bottle, 12.4 mL:
    Streptavidin-coated microparticles 0.72 mg/mL; preservative.

    R1 Anti-cortisol-Ab~biotin (gray cap), 1 bottle, 21.0 mL:
    Biotinylated monoclonal anti-cortisol antibody (mouse) 18 ng/mL; danazol 20 μg/mL; MES buffer 100 mmol/L, pH 6.0; preservative.

    R2 Cortisol-peptide~Ru(bpy) (black cap), 1 bottle, 21.0 mL:
    Cortisol derivative (synthetic), labeled with ruthenium complex, 5 ng/mL; danazol 20 μg/mL; MES buffer 100 mmol/L, pH 6.0; preservative.

    MES = 2-morpholino-ethane sulfonic acid

    AI/ML Overview

    The provided 510(k) summary for the Elecsys Cortisol III device focuses primarily on non-clinical performance evaluations to demonstrate substantial equivalence to a predicate device. It does not describe a study to prove performance against specific acceptance criteria for diagnostic accuracy (e.g., sensitivity, specificity, or agreement with ground truth in a clinical context) with a test set of patient samples.

    Here's an analysis of the available information:

    1. Acceptance Criteria and Reported Device Performance

    The document does not explicitly state "acceptance criteria" in the traditional sense for diagnostic performance metrics like sensitivity, specificity, or agreement against a clinical ground truth. Instead, it details performance specifications for various analytical aspects and states that these "met the predefined acceptance criteria." These are primarily related to the analytical performance of the assay itself.

    CategoryAcceptance Criteria (Not explicitly stated as clinical performance criteria, but implied as met from the document)Reported Device Performance (Summary of findings)
    PrecisionPredefined acceptance criteria met.Repeatability (cobas e 801 analyzer): CV ranges from 2.0% to 2.7% for human urine samples and controls. Intermediate Precision (cobas e 801 analyzer): CV ranges from 2.5% to 3.8% for human urine samples and controls. Reproducibility: Lot-to-lot reproducibility met predefined acceptance criteria.
    Analytical Sensitivity (LoB, LoD, LoQ)Predefined acceptance criteria met.LoB: 4.00 nmol/L (0.145 µg/dL) LoD: 7.50 nmol/L (0.272 µg/dL) LoQ: 10.0 nmol/L (0.363 µg/dL)
    Linearity/Assay Reportable RangePredefined acceptance criteria met.Reportable Range: 20.0 - 500 nmol/L (0.725 - 18.1 µg/dL)
    Human Anti-Mouse Antibodies (HAMA)Predefined acceptance criteria met.Differentiation between HAMA-negative and HAMA-positive samples assessed; data met acceptance criteria.
    Endogenous InterferencesNo significant interference.No significant interference observed for 13 endogenous substances (e.g., bilirubin, hemoglobin, intralipid, biotin, rheumatoid factor, various immunoglobulins, albumin, creatinine, glucose, NaCl, urea) up to the tested concentrations.
    Analytical Specificity/Cross-ReactivityExpected cross-reactivity profiles.Cross-reactivity % reported for various related steroids, with 11-Deoxycortisol (24.3%) and Allotetrahydrocortisol (11.3%) showing the highest cross-reactivity at the tested concentration. Many common steroids showed "n.d." (not detected) or very low cross-reactivity.
    Exogenous Interferences – DrugsNo interference with the assay at therapeutic concentrations for most drugs.No interference found for 12 commonly used pharmaceuticals. Prednisolone and hydrocortisone caused elevated cortisol concentrations. No interference observed for 6 methylprednisolone ≤ 0.157 mg/dL. Additional special drugs tested (amlodipine, betamethasone, beclomethasone, etc.) showed no interference.
    Method ComparisonPredefined acceptance criteria met.Data analyzed according to CLSI EP09-A3 and met all predefined acceptance criteria when compared to the predicate device (ARCHITECT Cortisol) using native 24-hour urine samples spanning the measuring range.
    StabilityPredefined acceptance criteria met.Supports claims for unopened reagents at 2-8 °C up to the stated expiration date and 16 weeks on the analyzer.
    Reference RangeEstablished reference range for healthy population.2.5th percentile: 24.8 nmol/24h (8.98 µg/24h) 97.5th percentile: 238 nmol/24h (86.2 µg/24h) for a healthy US population.

    2. Sample Size and Data Provenance for Test Set

    • Precision (Repeatability & Intermediate Precision): Human urine samples (24-hour urine) and controls. Two replicates per run, two runs per day for 21 days for each of 4 human urine samples and 2 controls. (Total of $4 \text{ samples} \times 2 \text{ replicates/run} \times 2 \text{ runs/day} \times 21 \text{ days} = 336$ measurements for human urine, plus $2 \text{ controls} \times 2 \text{ replicates/run} \times 2 \text{ runs/day} \times 21 \text{ days} = 168$ measurements for controls. Or potentially 42 total runs for each sample/control).
    • Analytical Sensitivity (LoB, LoD, LoQ): Not specified beyond "reagents and calibrators" likely being used.
    • Linearity/Assay Reportable Range: Dilution series contained a minimum of 9 concentrations. Number of samples not explicitly stated but implies a set of samples specifically created to span the measuring range.
    • HAMA: Not specified.
    • Endogenous Interferences: Human urine samples (24-hour urine) were used. The number of samples is not explicitly stated.
    • Analytical Specificity/Cross-Reactivity: Human urine (24-hour urine) samples. Specific numbers not provided beyond "samples were measured in the presence and absence of the potential cross-reactants."
    • Exogenous Interferences – Drugs: In vitro tests performed on 12 commonly used pharmaceuticals and additional special drugs. This implies spiked samples rather than a "test set" of patient samples.
    • Method Comparison: "Native 24 h urine samples" for comparison with the predicate device. The number of samples is not specified.
    • Reference Range Study: Samples collected from an "apparently healthy population in the United States" across three study sites. The exact number of samples is not provided, but it's sufficient for establishing 2.5th and 97.5th percentiles (typically requires 120+ samples according to CLSI EP28-A3c).

    Data Provenance: The document explicitly states "human urine samples (24-hour urine)" for most studies and for the reference range, "collected across three study sites... in the United States." This indicates prospective collection for the reference range study specifically for generating normal values applicable to the US population. For other analytical performance claims, the sample type (human urine) is generally mentioned, suggesting a similar provenance, likely for prospective testing within the manufacturer's lab or clinical sites.

    3. Number of Experts and Qualifications for Ground Truth

    Not applicable for the Elecsys Cortisol III. This is an in vitro diagnostic device (IVD) that quantitatively measures a biomarker (cortisol). The "ground truth" for such devices is typically established through recognized analytical standards, reference methods, and comparison to a legally marketed predicate device, rather than expert consensus on diagnostic images or clinical assessments. The closest to "ground truth" in this context would be the accuracy against a gold standard analytical method or purified cortisol standards. These details are not provided but are implicit in the validation that relies on CLSI guidelines.

    4. Adjudication Method for the Test Set

    Not applicable. As this is a quantitative IVD for a biomarker, diagnostic classification and adjudication by experts are not relevant to the described analytical studies. The performance is assessed by comparison to expected analytical results or a predicate device.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    Not applicable. MRMC studies are typically for imaging devices or software that assist human readers in making a diagnosis. The Elecsys Cortisol III is an automated in vitro diagnostic immunoassay for quantitative measurement of cortisol in urine. It does not involve human readers interpreting cases with or without AI assistance.

    6. Standalone Performance Study

    Yes, the entire submission describes standalone performance. The Elecsys Cortisol III is an immunoassay designed to operate on cobas e immunoassay analyzers. All the performance data (precision, sensitivity, linearity, interference, cross-reactivity, method comparison) are generated directly from the device's measurement of cortisol in urine samples. The device itself performs the quantitative determination without human-in-the-loop interpretation impacting the measurement results. The method comparison study directly compares its quantitative output to the predicate device's quantitative output.

    7. Type of Ground Truth Used

    For an IVD like Elecsys Cortisol III, the "ground truth" for the test set is established by:

    • Reference standards/Calibrators: For analytical sensitivity (LoB, LoD, LoQ) and linearity studies, known concentrations of cortisol (or materials traceable to them) are used.
    • Predicate device comparison: For method comparison, the results from the Elecsys Cortisol III are compared to those obtained from the legally marketed ARCHITECT Cortisol (K062204), which serves as the established "truth" or benchmark for demonstrating substantial equivalence.
    • Spiked samples/characterized samples: For interference and cross-reactivity studies, samples with known concentrations of interferents or cross-reactants are used to determine the device's accuracy in their presence.
    • Clinically characterized healthy population samples: For the reference range study, samples from healthy individuals are used to establish normal ranges, though this isn't a "ground truth" for diagnostic accuracy.

    8. Sample Size for the Training Set

    The document does not mention "training set" in the context of an AI/ML algorithm. This device is an immunoassay, which relies on chemical reactions and optical detection, not an AI/ML model that requires a training set. The term "training set" is therefore not applicable here.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable. As noted above, there is no AI/ML training set for this immunoassay device.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 48