Search Results
Found 60 results
510(k) Data Aggregation
(265 days)
a) ED-S100TP, ED-S100XP
This product has been designed for endoscopy and endoscopic surgery within the duodenum.
b) VS-1000
This product is a non-sterile, reusable display device designed to display live image data from FUJIFILM single-use endoscope.
a) ED-S100TP/ED-S100XP
This product is a medical electronic side viewing endoscope for duodenum, and it is inserted into the lumen, coelom, body cavity, or inside of the body, which provides images for observation, diagnosis, photographing, or treatment. The device is used for observation, diagnosis and treatment of the duodenum, in medical institutions under the supervision of a physician. The device is equipped with bending part which enables to move the distal end part in 4 different directions such as up and down, right and left. The device consists of a flexible tube with the bending part, and the operating part with the lever to operate the bending part. The tube inside of the flexible tube is installed from the operating part to the distal end part. Inserting treatment tools into the conduit line (referred as 'forceps channel') enables trans-endoscopic treatment.
This product is a sterile single-use device and is not intended for reprocessing.
b) VS-1000
This product has image processing, light source control, AE (shutter) control functions, a connector for endoscopes, and a connector for display units, and provides images for observation, diagnosis, photography, or treatment in body cavities by connecting the display unit and endoscope.
N/A
Ask a specific question about this device
(357 days)
a) EG-S100XT
This product is intended for the visualization of the upper digestive tract, specifically for the observation, diagnosis, and endoscopic treatment of the esophagus, stomach, and duodenum.
b) VS-1000
This product is a non-sterile, reusable display device designed to display live image data from FUJIFILM single-use endoscope.
A. Intended Use/Indications for Use
a) EG-S100XT
This product is intended for the visualization of the upper digestive tract, specifically for the observation, diagnosis, and endoscopic treatment of the esophagus, stomach, and duodenum.
b) VS-1000
This product is a non-sterile, reusable display device designed to display live image data from FUJIFILM single-use endoscope. For information on indications for use, refer to the operation manuals of compatible FUJIFILM single-use endoscopes.
B. Technological characteristics
a) EG-S100XT
This product is upper gastrointestinal endoscope, is inserted into a lumen, coelom, body cavity, or the inside of the body to provide these regions images for observation, diagnosis, and treatment. This product is inserted through the oral. The flexible tube (hereinafter "the insertion tube") follows the figure of the upper gastrointestinal tract performing a bending operation. The tip of the endoscope reaches to the duodenum. It is used for observation, diagnosis, and treatment of the esophagus, stomach, and duodenum.
Insertion portion of this product has a mechanism (hereinafter "the bending section") which bends the tip from right to left and up and down, and the insertion tube consists of the bending section and operating portion with a knob which controls the bending section. The instrument channel which runs through the operating portion to the tip is arranged inside the insertion portion for inserting the endotherapy device. This product is a sterile, single-use device and not intended to be reprocessed.
b) VS-1000
This product has image processing, light source control, AE (shutter) control functions, a connector for endoscopes, and a connector for display units, and provides images for observation, diagnosis, photography, or treatment in body cavities by connecting the display unit and endoscope.
C. Principles of Operation
a) EG-S100XT
The Endoscope Model EG-S100XT function on the same principles of operation as the predicate device.
This product is lighted by LED at the tip. Its reflection forms an image on CMOS image sensor through a group of object lens placed and set in the tip of this product. An electric signal from CMOS image sensor is transmitted to the processor connected to this product. The processor converts it to a video signal and displays an image on a monitor.
It is possible to do endoscopic fulguration, which enable a user to apply high-frequency electric current to objective regions inserting a high-frequency endotherapy device into the instrument channel of the operating portion. Since there are no exposed metal parts (conductive parts) on the endoscope surface that can be contacted in use, the endoscope can safely perform procedures using high-frequency current.
b) VS-1000
The product controls the light source mounted on the endoscope, receives electrical signals output from the endoscope's image sensor and outputs them as video signals to the display unit after performing image processing such as colour and image quality correction and enhancement.
The display unit's operating console and the endoscope application software built into the display unit are used to manage patient information, adjust white balance, and provide images and patient information to network devices.
N/A
Ask a specific question about this device
(81 days)
These hoods are intended to be used in combination with the compatible endoscope to maintain the field of view during endoscopic procedures or examinations.
These hoods are intended to be used in combination with the compatible endoscope to maintain the field of view during endoscopic procedures or examinations.
This product is attached to the tip of our endoscope and is designed to prevent the mucosa from obstructing the surgical field of view during observation of the digestive tract or during endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD), thereby ensuring a clear field of view during the procedure.
N/A
Ask a specific question about this device
(266 days)
This product is an ultrasonic endoscope intended for the observation, diagnosis and endoscopic treatment of the esophagus, trachea, bronchus and lesions adjacent to these structures using ultrasonic images, at medical facilities under the management of physicians.
This product is not intended for use on children and infants.
EB-710US (referred to as 'the device') is a medical ultrasonic electronic endoscope. The device is inserted into a lumen, a coelom, body cavity, or inside of a body, and provides images for observation, diagnosis, photographing, or treatment. It is also used for ultrasonography by visualizing the shape, the characteristic, or the dynamics of the inside of the body.
This product is comprised of three general sections: an insertion portion, a control portion, and a connector portion to the peripherals. The insertion portion is flexible and contains glass fiber bundles, a channel, a complementary metal-oxide semiconductor (CMOS) image sensor and a ultrasonic transducer in its distal end. The glass fiber bundles allow light to travel through the endoscope and emit light from the tip of the insertion portion to illuminate the body cavity. This provides enough light to the CMOS image sensor to capture an image and display it on the monitor. The channel in the insertion portion assist in delivering suction as well as endoscopic accessories. The control portion controls the angulation of the bending portion in the insertion portion. The connector portion consists of electronic components needed to operate the endoscope when connected to the video processor.
This product is used in combination with FUJIFILM's video processors, light sources, and peripheral devices such as monitor, printer, foot switch, and cart. And the device drives ultrasonic transducer installed in the distal end of the device by being connected with a ultrasonic processor.
The driven ultrasonic transducer emits ultrasound into the body, and receives the reflected ultrasonic signal from the body. The ultrasonic processor connected to the device performs image processing using the received signal. The electric signal of the image processing is converted into video signal, and it is output to the monitor as a ultrasonic image.
N/A
Ask a specific question about this device
(135 days)
The ECHELON Synergy System is an imaging device and is intended to provide the physician with physiological and clinical information, obtained non-invasively and without the use of ionizing radiation. The MR system produces transverse, coronal, sagittal, oblique, and curved cross sectional images that display the internal structure of the head, body, or extremities. The images produced by the MR system reflect the spatial distribution of protons (hydrogen nuclei) exhibiting magnetic resonance. The NMR properties that determine the image appearance are proton density, spin-lattice relaxation time (T1), spin-spin relaxation time (T2) and flow. When interpreted by a trained physician, these images provide information that can be useful in diagnosis determination.
The ECHELON Synergy is a Magnetic Resonance Imaging System that utilizes a 1.5 Tesla superconducting magnet in a gantry design. The control and image processing hardware and the base elements of the system software are identical to the predicate device.
This document describes the ECHELON Synergy MRI system's acceptance criteria and the studies conducted to demonstrate its performance. The submission for FDA 510(k) clearance (K251386) references a predicate device, the ECHELON Synergy MRI System (K241429), and outlines modifications to hardware and software.
1. Table of Acceptance Criteria and Reported Device Performance
The document does not explicitly present a table of "acceptance criteria" against which a numeric performance metric is listed for each new feature. Instead, it details that certain functionalities (DLR Symmetry and AutoPose) underwent performance evaluations. The "performance" reported is described qualitatively or comparatively to conventional methods.
| Feature/Metric | Acceptance Criteria (Implicit/Derived) | Reported Device Performance |
|---|---|---|
| DLR Symmetry - Artifact Reduction | Reduction of artifacts should be demonstrated. | Phantom testing demonstrated DLR Symmetry could reduce artifacts in the image using Normalized Root Mean Square Error (NRMSE). Clinical image review by radiologists indicated superior artifact reduction (p<0.05) compared to conventional images. |
| DLR Symmetry - Image Quality (SNR, Sharpness, Contrast, Lesion Conspicuity, Overall) | Should not degrade image quality compared to conventional methods. Images should be clinically acceptable. | Phantom Testing: Did not degrade image quality based on SNR, Relative Edge Sharpness, and Contrast Change Rate. Clinical Image Review: Radiologists reported superior SNR, image sharpness, lesion conspicuity, and overall image quality (p<0.05) in DLR Symmetry images. All DLR Symmetry images were evaluated as clinically acceptable. |
| AutoPose (Shoulder, Knee, HipJoint, Abdomen, Pelvis (male/female), Cardiac) - Automatic Slice Positioning | Should be able to set slice positions for a scan without manual adjustment in most cases. For remaining cases, user operation steps should be equivalent to manual positioning. | Evaluation by certified radiological technologists showed that "almost cases" were able to set slice positions without manual adjustment. The remaining cases required user operation steps equivalent to manual slice positioning. |
2. Sample Sizes Used for the Test Set and Data Provenance
- DLR Symmetry:
- Clinical Image Test Set: 89 unique subjects (patients and healthy subjects).
- Data Provenance: From U.S. and Japan.
- Data Type: Retrospective (clinical images collected).
- AutoPose:
- Shoulder: 60 cases
- Knee: 60 cases
- HipJoint: 65 cases
- Abdomen: 115 cases
- Pelvis for male: 60 cases
- Pelvis for female: 68 cases
- Cardiac: 126 cases
- Data Provenance: FUJIFILM Corp., FUJIFILM Healthcare Americas Corp., and clinical sites.
- Data Type: Subject type includes healthy volunteers and patients, implying a mix of prospective data collection for testing new features and potentially retrospective for some patient data.
3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications
- DLR Symmetry:
- Number of Experts: Three US board certified radiologists.
- Qualifications: "US board certified radiologists." Specific years of experience are not mentioned.
- AutoPose:
- Number of Experts/Evaluators: Three certified radiological technologists.
- Qualifications: "Certified radiological technologists." Specific years of experience are not mentioned.
4. Adjudication Method for the Test Set
- DLR Symmetry: The document states that comparisons were made by "the reviewers" (plural) in terms of image quality metrics using a 3-point scale. It doesn't explicitly state an adjudication method like 2+1 or 3+1 if there were disagreements among the three radiologists. It implies a consensus or majority rule might have been used for the reported "superior" findings, but this isn't detailed.
- AutoPose: The evaluation results are simply described as "evaluation results showed," implying a summary of the technologists' findings. No specific adjudication method is described.
5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done
- DLR Symmetry: A form of MRMC study was conducted where three US board-certified radiologists reviewed images reconstructed with DLR Symmetry versus conventional methods.
- Effect Size of Human Readers with AI vs. Without AI Assistance: The document indicates that images with DLR Symmetry (AI-assisted reconstruction) were "superior to those in the conventional images with statistically significant difference (p<0.05)" across various image quality metrics. This shows an improvement in the perceived image quality for human readers when using DLR Symmetry, but it does not quantify the "effect size of how much human readers improve with AI vs. without AI assistance" in terms of diagnostic performance (e.g., improved sensitivity/specificity for a given task). Instead, it focuses on the quality of the image presented to the reader.
6. If a Standalone (i.e. algorithm only without human-in-the-loop performance) was done
- DLR Symmetry: Yes, in part. Phantom testing was conducted to evaluate artifact reduction (NRMSE), SNR, Relative Edge Sharpness, and Contrast Change Rate. This is an algorithmic performance evaluation independent of human interpretation of clinical images, although it assesses image characteristics rather than diagnostic output.
- AutoPose: The evaluation by certified radiological technologists focuses on the algorithm's ability to set slice positions automatically, which is a standalone performance metric for the automation function.
7. The Type of Ground Truth Used
- DLR Symmetry:
- For phantom testing: "Ground truth" refers to the known characteristics of the phantom and metrics like NRMSE, SNR, etc.
- For clinical image review: The ground truth was established by expert consensus or individual assessment of the "clinical acceptability" of the images and comparative judgment (superiority) of image quality metrics by three US board-certified radiologists. This isn't pathology or outcomes data, but rather expert radiological opinion on image quality and clinical utility.
- AutoPose: The "ground truth" was whether the automated positioning successfully set the slice positions without manual adjustment, as evaluated by certified radiological technologists.
8. The Sample Size for the Training Set
The document explicitly states regarding DLR Symmetry: "The test dataset was independent of the training and validation datasets." However, it does not provide the sample size or details for the training set (or validation set) for DLR Symmetry or AutoPose.
9. How the Ground Truth for the Training Set Was Established
The document does not provide details on how the ground truth for the training set was established for either DLR Symmetry or AutoPose, as the training set details are not included in the provided text.
Ask a specific question about this device
(168 days)
a. Endoscope Model EB-710P
Endoscope Model EB-710P is a bronchoscope intended for the observation, diagnosis and endoscopic treatment of the trachea and bronchus at medical facilities under the management of physicians. Never use this product for any other purposes.
b. Processor EP-8000
The EP-8000 is an endoscopic processor with an integrated light source that is intended to provide illumination, process electronic signals transmitted from a video endoscope and enable image recording.
This product can be used in combination with compatible medical endoscope, a monitor, a recorder and various peripherals.
It is used for endoscopic observation, diagnosis and treatment.
a. Endoscope Model EB-710P
FUJIFILM Endoscope Model EB-710P is comprised of three general sections: an insertion portion, a control portion, and a connector portion to the peripherals. The insertion portion is flexible and contains glass fiber bundles, several channels, and a complementary metal-oxide semiconductor (CMOS) image sensor in its distal end. The glass fiber bundles allow light to travel through the endoscope and emit light from the tip of the insertion portion to illuminate the body cavity. This provides enough light to the CMOS image sensor to capture an image and display it on the monitor. The channels in the insertion portion assist in delivering suction as well as endoscopic accessories. The control portion controls the angulation and rotation of the bending portion in the insertion portion. The connector portion consists of electronic components needed to operate the endoscope when connected to the video processor. The endoscopes are used in combination with FUJIFILM's video processors, light sources, and peripheral devices such as monitor, printer, foot switch, and cart.
b. Processor EP-8000
FUJIFILM Video Processor EP-8000 is intended to provide illumination, process electronic signals transmitted from a video endoscope and enable image recording.
FUJIFILM Video Processor EP-8000 relays the image from an endoscope to a video monitor. The projection can be either analog or digital at the user's preference. The processor employs fiber bundles to transmit light from four LED lamps (Violet, Blue, Green, and Amber), with a total power of 79.2W lamps, to the body cavity.
The device is AC operated at a power setting of 100-240V/50-60Hz/ 3.0-1.5A. The processor is housed in a steel-polycarbonate case measuring 395×210×515mm
The provided FDA 510(k) clearance letter pertains to the FUJIFILM Endoscope Model EB-710P and Processor EP-8000. It details the substantial equivalence of these devices to their predicates based on non-clinical testing.
However, the provided text does not contain information about acceptance criteria or a study that uses a test set to prove the device meets those criteria.
The document primarily focuses on:
- Product identification: Device names, regulation numbers, product codes.
- Regulatory details: FDA clearance status, general controls, and compliance requirements.
- Substantial equivalence justification: Comparison of intended use, technological characteristics, and principles of operation between the new devices and their predicates.
- Non-clinical testing: A list of engineering tests performed (e.g., electrical safety, software validation, color and optical performance, image quality assessments like reproduction, geometric distortion, resolution, depth of field, ISO-SNR, dynamic range, intensity uniformity, and field of view).
Therefore, I cannot fulfill the request to describe the acceptance criteria and the study that proves the device meets them, as this information is not present in the provided FDA clearance letter.
To answer your request, I would need a document (e.g., a summary of safety and effectiveness, or a clinical study report) that explicitly defines:
- Acceptance criteria: Quantitative thresholds or qualitative statements that define successful device performance.
- Reported device performance: The actual outcomes measured during the study.
- Test set details: Sample size, data provenance, ground truth establishment (experts, adjudication, type of ground truth).
- Training set details: Sample size, ground truth establishment.
- MRMC study information: If applicable, whether human readers improved with AI assistance and by how much.
- Stand-alone algorithm performance: If an algorithm-only study was conducted.
The provided document only states that "EP-8000 demonstrated substantial equivalence to VP-7000 and BL-7000 in Image performance and color reproduction" for the listed non-clinical tests, implying that the new device performed as well as the predicate for these specific engineering parameters, but it does not provide the specific performance values or the acceptance thresholds for these parameters. It also makes no mention of AI assistance or human reader studies.
Ask a specific question about this device
(210 days)
FUJIFILM Endoscope Models EG-840T and EG-840TP is intended for the visualization of the upper digestive tract, specifically for the observation, diagnosis, and endoscopic treatment of the esophagus, stomach, and duodenum.
FUJIFILM Endoscope Model EG-840N is intended for the visualization of the upper digestive tract, specifically for the observation, diagnosis, and endoscopic treatment of the esophagus, stomach, and duodenum. This product can be inserted orally or nasally.
Never use this product for any other purposes.
The insertion portion of the device has a mechanism (hereinafter "the bending portion") which bends the tip from right to left and up and down, and a flexible tube (hereinafter "the flexible portion") consists of the bending portion and operating portion with a knob which controls the bending portion. The forceps channel which runs through the operating portion to the tip is arranged inside the insertion portion for inserting the surgical instrument. The insertion portion of the endoscopes comes into contact with the mucosal membrane.
The tip of the insertion portion is called the "Distal end" which contains the Imaging section, Distal cap, Objective lens, Air/water nozzle, Water jet nozzle (Except EG-840N), Instrument channel outlet, and Light guide. The bending portion is controlled by knobs on the control portion/operation section to angulate the distal end to certain angles.
The Flexible portion refers to the long insertion area between the Bending portion and the Control portion (a part of Non-insertion portion). This portion contains light guides (glass fiber bundles), air/water channels, a forceps/suction channel, a CrOS image sensor, and cabling. The glass fiber bundles allow light to travel through the endoscope to illuminate the body cavity, thereby providing enough light to the CMOS image sensor to capture an image and display the image on a monitor. The forceps channel is used to introduce biopsy forceps and other endoscopic accessories, as well as providing suction.
The control portion/operating section provides a grip to grasp the endoscopes and contains mechanical parts to operate the endoscopes. This section includes a Forceps inlet, which allows endoscope accessories to be introduced. The Scope connector connects the endoscopes to the light source.
The provided FDA 510(k) clearance letter pertains to endoscopes, which are hardware devices, not AI/ML software. Therefore, the information requested regarding acceptance criteria, study details, and data provenance for an AI/ML device is not explicitly present in the provided text.
The document focuses on demonstrating substantial equivalence to a predicate device through various non-clinical tests (electrical safety, biocompatibility, endoscope-specific testing, software validation, and reprocessing validation) rather than a clinical effectiveness study involving human readers or AI performance metrics.
However, I can extract information about the device's performance specifications that were tested to prove its general functionality and safety, which can be interpreted as fulfilling certain "acceptance criteria" for a physical medical device.
Here's a breakdown of the available information based on your request, with the caveat that it does not directly address AI/ML performance:
1. A table of acceptance criteria and the reported device performance
The document lists various performance specifications that the device met. It does not provide specific numerical acceptance criteria alongside reported performance values in a table format. Instead, it states that "The subject device met performance specifications in the following additional testing." This implies that the device did meet predefined internal thresholds for these parameters.
| Acceptance Criterion (Performance Specification Tested) | Reported Device Performance |
|---|---|
| Field of view | Met performance specifications |
| Diameter of forceps channel | Met performance specifications |
| Uneven illumination | Met performance specifications |
| Bending capability | Met performance specifications |
| Viewing direction | Met performance specifications |
| Color reproducibility | Met performance specifications |
| Rate of suction | Met performance specifications |
| Resolution | Met performance specifications |
| Air volume | Met performance specifications |
| Working length | Met performance specifications |
| LG output | Met performance specifications |
| Water volume | Met performance specifications |
| Electrical safety | Met specified standards (ANSI/AAMI ES 60601-1:2012, IEC 60601-1-2:2020, IEC60601-1-6:2020 and IEC 60601-2-18:2009) |
| Biocompatibility | Met specified standards (ISO 10993-1:2018, ISO 10993-5:2009, and ISO 10993-10:2010), in accordance with FDA guidance. |
| Endoscope specific testing | Met specified standards (ISO 8600-1:2015, ISO 8600-3:2019, and ISO 8600-4:2014) |
| Software specific testing (Validation) | Met specified standards (IEC 62304:2015), in accordance with FDA guidance. |
| Cleaning, disinfection, and sterilization instructions validation | Met FDA guidance, demonstrated substantial equivalence in performance to predicate device after reprocessing. |
2. Sample size used for the test set and the data provenance
- Sample Size: Not specified for any of the tests. The document mentions "testing" or "validation activities" without detailing the number of devices or trials involved.
- Data Provenance: Not specified. As this is a 510(k) for a physical medical device (endoscope), the testing would typically be conducted in a laboratory setting by the manufacturer, rather than involving patient data in the context of imaging performance.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts
Not applicable. The tests performed are engineering and safety validations. There is no mention of human expert involvement for establishing "ground truth" in the context of image interpretation or diagnosis, as this is not an AI/ML diagnostic tool.
4. Adjudication method (e.g. 2+1, 3+1, none) for the test set
Not applicable. This is a concept typically used in clinical studies involving interpretation by multiple readers, which is not described here.
5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
Not applicable. This is not an AI-assisted device. The document describes a traditional endoscope.
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
Not applicable. The device itself is an endoscope, not an algorithm. Software validation was conducted (IEC 62304:2015), but this relates to the software controlling the endoscope's functions, not a standalone diagnostic AI.
7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)
For the listed performance specifications (field of view, resolution, etc.), the "ground truth" would be established by objective physical measurements using calibrated equipment and engineering standards. For biocompatibility, it's based on biological response to materials, and for reprocessing, it's based on sterility and decontamination efficacy. There is no "ground truth" in the diagnostic sense as there would be for an AI/ML algorithm.
8. The sample size for the training set
Not applicable. This is not an AI/ML device that requires a training set.
9. How the ground truth for the training set was established
Not applicable.
Ask a specific question about this device
(220 days)
This product is intended for the visualization of the lower digestive tract, specifically for the observation, diagnosis, and endoscopic treatment of the rectum and large intestine.
The insertion portion of the device has a bending mechanism and a flexible tube consisting of the bending portion and an operating portion with a knob to control the bending. A forceps channel runs through the operating portion to the tip for inserting surgical instruments. The insertion portion's tip, called the "Distal end," contains the Imaging section, Distal cap, Objective lens, Air/water nozzle, Water jet nozzle, Instrument channel outlet, and Light guide. The bending portion is controlled by knobs on the control portion/operation section. The flexible portion, between the bending and control portions, contains light guides (glass fiber bundles), air/water channels, a forceps/suction channel, a CMOS image sensor, and cabling. The control portion/operating section provides a grip and mechanical parts to operate the endoscopes, including a Forceps inlet. The Scope connector links the endoscopes to the light source and video processor.
The provided FDA 510(k) clearance letter and summary for the FUJIFILM Endoscope Models EC-860P/M, EC-860P/L, and EC-860S/L primarily focus on demonstrating substantial equivalence to predicate devices through bench testing and compliance with various consensus standards. It does not describe a clinical study in the traditional sense, where device performance is measured against specific acceptance criteria in a human subject population using metrics like sensitivity, specificity, or accuracy, often seen with AI or diagnostic imaging devices.
Instead, the submission relies on demonstrating that the new endoscope models meet established performance specifications and safety standards through non-clinical testing.
Here's an analysis based on the provided text, addressing your questions where information is available:
1. Table of Acceptance Criteria and Reported Device Performance
The document does not explicitly state numerical acceptance criteria for each item. Instead, it refers to the subject device meeting "performance specifications" or demonstrating "substantially equivalent in performance to the predicate devices" for various parameters.
| Acceptance Criteria (Implied) | Reported Device Performance |
|---|---|
| Electrical safety compliance (ANSI/AAMI ES 60601-1, IEC 60601-1-2, IEC60601-1-6, IEC 60601-2-18) | Met standards |
| Biocompatibility compliance (ISO 10993-1, ISO 10993-5, ISO 10993-10) | Met standards; no new concerns for safety/efficacy. |
| Endoscope specific testing compliance (ISO 8600-1, ISO 8600-3, ISO 8600-4) | Met standards. |
| Software specific testing compliance (IEC 62304) | Met standards; validation performed. |
| Reprocessing Validation (Cleaning, Disinfection, Sterilization) | Performed in accordance with FDA guidance. |
| Optical Performance: | |
| - Field of view | Subject device met performance specifications. |
| - Resolution | Subject device met performance specifications; demonstrated substantial equivalence to predicate. |
| - Color reproducibility | Subject device met performance specifications. |
| - Uneven illumination | Subject device met performance specifications. |
| Mechanical/Operational Performance: | |
| - Diameter of forceps channel | Subject device met performance specifications. |
| - Bending capability | Subject device met performance specifications. |
| - Viewing direction | Subject device met performance specifications. |
| - Rate of suction | Subject device met performance specifications. |
| - Air volume | Subject device met performance specifications. |
| - Water volume | Subject device met performance specifications. |
| - Working length | Subject device met performance specifications. |
| - LG output | Subject device met performance specifications. |
| - Distal end diameter (for EC-860P/M) | Value is between predicate and reference devices, no safety/efficacy concern. |
| - Distal end diameter (for EC-860P/L) | Same as reference device, no safety/efficacy concern. |
| - Distal end diameter, flexible portion diameter, max diameter (for EC-860S/L) | Same as reference device, no safety/efficacy concern. |
| Materials | Differences in materials validated through biocompatibility testing; no new safety/efficacy concern. |
2. Sample size used for the test set and the data provenance
No human or patient test set is described. The "test set" consists of the physical endoscope models themselves, subjected to various bench tests and standard compliance evaluations. The data provenance is derived from these non-clinical tests performed by the manufacturer, rather than patient data.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts
Not applicable. This is not a study requiring expert readers to establish ground truth for clinical performance. The "ground truth" for the non-clinical tests is established by the specifications and standards themselves, and verified by testing personnel.
4. Adjudication method for the test set
Not applicable. There is no expert adjudication process described for clinical interpretation. The compliance with standards and performance specifications is determined through objective measurements and validated test methods.
5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
Not applicable. This device is an endoscope, not an AI-powered diagnostic system. No MRMC study or AI assistance is mentioned. The clearance is for the physical endoscope models.
6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done
Not applicable. There is no AI algorithm involved in this device submission.
7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)
For this submission, the "ground truth" is defined by:
- Consensus standards: e.g., electrical safety (ANSI/AAMI ES 60601-1), biocompatibility (ISO 10993-1), medical device software (IEC 62304), endoscope-specific standards (ISO 8600 series).
- Manufacturer's internal performance specifications: These are the benchmarks against which specific performance parameters (e.g., field of view, resolution, bending capability) are measured.
- Predicate device performance: The "bench testing data regarding 'Optical performance' demonstrated that the subject devices are substantially equivalent in performance to the predicate devices." This implies that the performance of the predicate devices serves as a comparative ground truth for equivalence.
8. The sample size for the training set
Not applicable. This is not a machine learning or AI device that requires a training set.
9. How the ground truth for the training set was established
Not applicable. No training set is described.
Ask a specific question about this device
(166 days)
Synapse 3D Base Tools is medical imaging software that is intended to provide trained medical professionals with tools to aid them in reading, interpreting, reporting, and treatment planning. Synapse 3D Base Tools accepts DICOM compliant medical images acquired from a variety of imaging devices including, CT, MR, CR, US, NM, PT, and XA, etc.
This product is not intended for use with or for the primary diagnostic interpretation of Mammography images. Synapse 3D Base Tools provides several levels of tools to the user: Basic imaging tools for general images, including 2D viewing, volume rendering and 3D volume viewing, orthogonal / oblique / curved Multi-Planar Reconstructions (MPR), Maximum (MIP), Average (RaySum) and Minimum (MinIP) Intensity Projection, 4D volume viewing, image fusion, image subtraction, surface rendering, sector and rectangular shape MPR image viewing, MPR for dental images, creating and displaying multiple MPR images along an object, time-density distribution, basic image processing, noise reduction, CINE, measurements, annotations, reporting, printing, storing, distribution, and general image management and administration tools, etc.
• Tools for regional segmentation of anatomical structures within the image data, path definition through vascular and other tubular structures, and boundary detection.
• Image viewing tools for modality specific images, including CT PET fusion and ADC image viewing for MR studies.
• Imaging tools for CT images including virtual endoscopic viewing, dual energy image viewing.
• Imaging tools for MR images including delayed enhancement image viewing, diffusion-weighted MRI image viewing.
The intended patient population for all applications implemented as base tools is limited to adult population (over 22 years old).
The 3D image analysis software Synapse 3D Base Tools (V7.0) is medical application software running on Windows server/client configuration installed on commercial general-purpose Windows-compatible computers. It offers software tools which can be used by trained professionals to interpret medical images obtained from various medical devices, to create reports, or to develop treatment plans.
The provided text details the FDA 510(k) clearance for Synapse 3D Base Tools (V7.0). It primarily focuses on demonstrating substantial equivalence to a predicate device and includes information on nonclinical and certain clinical performance testing for newly added deep-learning-based organ segmentation features.
Here's an analysis of the acceptance criteria and study that proves the device meets them, based on the provided text:
Acceptance Criteria and Reported Device Performance
The core of acceptance criteria for this 510(k) submission appears to be demonstrating substantial equivalence to a predicate device (Synapse 3D Base Tools V6.6 K221677) and proving the safety and effectiveness of new features, particularly those utilizing deep learning for automatic or semi-automatic organ extraction.
While no explicit "acceptance criteria" table is provided in the document in terms of specific thresholds for the overall device functionality, the performance section for the deep learning models serves as such for those specific features. The acceptance criterion for these features is implicitly showing a high Dice Similarity Coefficient (DICE) score, indicating strong agreement between the automated segmentation and the ground truth.
Table of Acceptance Criteria and Reported Device Performance (for Deep Learning Segmentation)
| Segmented Structure (Modality) | Number of Cases | Acceptance Criteria (Implicit) - High DICE Score | Reported Device Performance (Average DICE) |
|---|---|---|---|
| Duodenum (CT) | 30 | High DICE | 0.85 |
| Stomach (CT) | 30 | High DICE | 0.96 |
| Lung section (Left S1S2) (CT) | 30 | High DICE | 0.92 |
| Lung section (Left S3) (CT) | 30 | High DICE | 0.88 |
| Lung section (Left S4) (CT) | 30 | High DICE | 0.75 |
| Lung section (Left S5) (CT) | 30 | High DICE | 0.81 |
| Lung section (Left S6) (CT) | 30 | High DICE | 0.9 |
| Lung section (Left S8) (CT) | 30 | High DICE | 0.85 |
| Lung section (Left S9) (CT) | 30 | High DICE | 0.73 |
| Lung section (Left S10) (CT) | 30 | High DICE | 0.87 |
| Lung section (Right S1) (CT) | 30 | High DICE | 0.89 |
| Lung section (Right S2) (CT) | 30 | High DICE | 0.89 |
| Lung section (Right S3) (CT) | 30 | High DICE | 0.91 |
| Lung section (Right S4) (CT) | 30 | High DICE | 0.88 |
| Lung section (Right S5) (CT) | 30 | High DICE | 0.85 |
| Lung section (Right S6) (CT) | 30 | High DICE | 0.9 |
| Lung section (Right S7) (CT) | 30 | High DICE | 0.8 |
| Lung section (Right S8) (CT) | 30 | High DICE | 0.84 |
| Lung section (Right S9) (CT) | 30 | High DICE | 0.71 |
| Lung section (Right S10) (CT) | 30 | High DICE | 0.83 |
| Pancreas section (Body) (CT) | 29 | High DICE | 0.91 |
| Pancreas section (Head) (CT) | 29 | High DICE | 0.95 |
| Pancreas section (Tail) (CT) | 29 | High DICE | 0.99 |
| Spleen (CT) | 35 | High DICE | 0.95 |
| Pancreas duct (CT) | 29 | High DICE | 0.74 |
| Pancreas (CT) | 30 | High DICE | 0.86 |
| ROI (CT)* | 29 | High DICE | 0.85 |
| Liver section (S1) (CT) | 31 | High DICE | 0.99 |
| Liver section (S2) (CT) | 31 | High DICE | 0.99 |
| Liver section (S3) (CT) | 31 | High DICE | 0.97 |
| Liver section (S4) (CT) | 31 | High DICE | 0.97 |
| Liver section (S5) (CT) | 31 | High DICE | 0.92 |
| Liver section (S6) (CT) | 31 | High DICE | 0.94 |
| Liver section (S7) (CT) | 31 | High DICE | 0.98 |
| Liver section (S8) (CT) | 31 | High DICE | 0.97 |
| Gall bladder (CT) | 37 | High DICE | 0.92 |
| Bronchus (CT) | 30 | High DICE | 0.87 |
| Lung lobe (Left Lower) (CT) | 30 | High DICE | 0.99 |
| Lung lobe (Left Upper) (CT) | 30 | High DICE | 0.99 |
| Lung lobe (Right Lower) (CT) | 30 | High DICE | 0.99 |
| Lung lobe (Right Middle) (CT) | 30 | High DICE | 0.97 |
| Lung lobe (Right Upper) (CT) | 30 | High DICE | 0.99 |
| Pulmonary Arteries (CT) | 30 | High DICE | 0.83 |
| Pulmonary Veins (CT) | 30 | High DICE | 0.85 |
| Pancreas vessel (CT) | 30 | High DICE | 0.9 |
| Prostate (MRI) | 30 | High DICE | 0.9 |
| Rectal ROI (tumor) (MRI)* | 27 | High DICE | 0.75 |
| Ureter (T2) (MRI) | 33 | High DICE | 0.63 |
| Bladder (MRI) | 35 | High DICE | 0.93 |
| Pelvis (MRI) | 34 | High DICE | 0.94 |
| Seminal vesicle (MRI) | 32 | High DICE | 0.7 |
| Ureter (T1Dynamic) (MRI) | 33 | High DICE | 0.76 |
| Prostate tumor (DWI) (MRI)* | 36 | High DICE | 0.65 |
| Prostate tumor (T2) (MRI)* | 39 | High DICE | 0.6 |
| Kidney tumor (MRI)* | 31 | High DICE | 0.88 |
| Left Kidney (MRI) | 31 | High DICE | 0.97 |
| Right Kidney (MRI) | 31 | High DICE | 0.98 |
| ROI (MRI)* | 133 | High DICE | 0.72 |
| Rectal muscularis propria (MRI) | 32 | High DICE | 0.91 |
| Mesorectum (MRI) | 32 | High DICE | 0.9 |
| Pelvic vessel (Artery) (MRI) | 30 | High DICE | 0.81 |
| Pelvic vessel (Vein) (MRI) | 30 | High DICE | 0.8 |
| Kidney vessel (Artery) (MRI) | 32 | High DICE | 0.92 |
| Kidney vessel (Vein) (MRI) | 32 | High DICE | 0.86 |
| Pelvic nerve (MRI) | 30 | High DICE | 0.7 |
| Levator ani muscle (MRI) | 30 | High DICE | 0.77 |
| Overall (Total cases) | 1086 | Consistent and Acceptable Performance | Range of 0.60 to 0.99 (Average DICE) |
Note: For items marked with an asterisk (*), the extraction is performed semi-automatically. All others are executed automatically. The acceptance criterion is "High DICE," as no specific quantitative threshold is given, but the reported values generally indicate good agreement. "Additional distance based metrics 95% Hausdorff Distance and Mean Surface Distance were also reported along with the subgroup analysis. Detailed results are reported in the labeling."
Study that Proves the Device Meets Acceptance Criteria
The study described is a performance testing for the new deep-learning-based automatic or semi-automatic organ extraction functions.
-
Sample size used for the test set and the data provenance:
- Sample Size: 1086 cases were collected for performance testing.
- Data Provenance: The data was collected newly from US patient populations across various regions: US_East (295 cases), US_Midwest (175 cases), US_Southeast (185 cases), US_Southwest (73 cases), and US_Northwest (4 cases). This indicates a prospective data collection specifically for this testing, originating from the US. The text also mentions the test data is "independence from training data."
- Demographics: The test set included 672 men, 414 women, and a range of ages from 22 to 120+ years old. Modalities covered CT and MRI from various major manufacturers (SIEMENS, GE, PHILIPS, CANON, FUJIFILM).
-
Number of experts used to establish the ground truth for the test set and the qualifications of those experts:
- The document does not specify the number of experts or their qualifications used to establish the ground truth. It only states that the performance testing used an "average DICE" score, implying a comparison against some form of expertly derived ground truth.
-
Adjudication method (e.g. 2+1, 3+1, none) for the test set:
- The document does not specify any adjudication method for establishing the ground truth.
-
If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:
- No, an MRMC comparative effectiveness study was not explicitly mentioned or performed as part of this submission for demonstrating substantial equivalence. The clinical testing mentioned focused on the standalone performance of the new deep learning features (i.e., automatic or semi-automatic segmentation accuracy) rather than human reader performance with or without AI assistance. The submission states, "The subject of this 510(k) notification, Synapse 3D Base Tools does not require clinical studies to support safety and effectiveness of the software."
-
If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:
- Yes, a standalone performance evaluation was done for the automatic (and semi-automatic) deep learning segmentation functions. The Dice Similarity Coefficient (DICE) scores provided are a measure of the algorithm's performance in segmenting anatomical structures compared to a ground truth, without human intervention in the segmentation process itself, although some extractions are noted as "semi-automatic" where human interaction would refine the output.
-
The type of ground truth used (expert consensus, pathology, outcomes data, etc.):
- The text implies the ground truth for the segmentation tasks was established by expert consensus/manual annotation (as DICE is a metric comparing algorithmic output to a reference segmentation, typically derived from expert outlines). However, the specific method (e.g., single expert, multi-expert consensus) is not detailed. It mentions "Additional distance based metrics 95% Hausdorff Distance and Mean Surface Distance were also reported," which are also used for comparing segmentation masks to a ground truth.
-
The sample size for the training set:
- The document does not explicitly provide the sample size for the training set. It only states that the test data was "independence from training data," implying a separate training dataset was used.
-
How the ground truth for the training set was established:
- The document does not provide details on how the ground truth for the training set was established. However, for deep learning segmentation, it is typically established through manual annotation by qualified experts.
Ask a specific question about this device
(99 days)
The SCENARIA View system is indicated to acquire axial volumes of the whole body including the head. Images can be acquired in axial, helical, or dynamic modes. The SCENARIA View system can also be used for interventional needle guidance. Volume datasets acquired by a SCENARIA View system can be post-processed in the SCENARIA View system to provide additional information. Post-processing capabilities of the SCENARIA View software include multi-planar reconstruction (MPR), and volume rendering. Volume datasets acquired by a SCENARIA View system can be transferred to external devices via a DICOM standard interface.
The Low Dose CT Lung Cancer Screening Option for the SCENARIA View system is indicated for using low dose CT for lung cancer screening. The screening must be conducted with the established program criteria and protocols that have been approved and published by a governmental body, a professional medical society, and/or FUJIFILM Corporation.
The SCENARIA View system is intended for general populations.
The subject device SCENARIA View is a multi-slice CT system consists of a gantry, operator's workstation, patient table, high-frequency X-ray generator, and accessories. The system performance is similar to the predicate device.
The SCENARIA View system uses 128-slice CT technology, where the X-ray tube and detector assemblies are mounted on a frame that rotates continuously around the patient using slip ring technology. The solid-state detector assembly design collects up to 64 slices of data simultaneously. The X-ray sub-system features a high frequency generator, X-ray tube, and collimation system that produces a fan beam X-ray output. The system can operate in a helical (spiral) scan mode where the patient table moves during scanning. As the X-ray tube/detector assembly rotates around the patient, data is collected at multiple angles.
The collected data is then reconstructed into cross-sectional images by a high-speed reconstruction sub-system. The images are displayed on a Computer Workstation, stored, printed, and archived as required. The workstation is based on current PC technology using the Windows™ operating system.
Compared to the predicate device referenced within this submission, the subject devices support the following modifications:
- New features
- AutoPose is an AI-based function that recognizes a specific body part in an image of localization scan and then automatically sets the scan range and the image reconstruction range.
- RemoteRecon is a function of setting image reconstruction parameters that runs on the external personal computer (hereinafter referred to as "PC") connected to the CT system.
- Modified features
- The maximum load capacity of patient table type has been increased from 250kg to 300 kg.
- Motion corrected reconstruction is an image reconstruction feature that reduces motion artifacts. The feature has been modified to include applicability for chest examinations, which is a non-gated scan.
- AutoPositioning is a feature that assist in positioning the patient by camera images. The feature has been modified to include additional 12 body parts (Head and Neck, Neck, C-spine, Heart, Chest-Abdomen, Chest-Upper Abdomen, Abdomen-Pelvis, Abdomen, Pelvis, T-spine, L-spine, T-L-spine), in addition to the 2 body parts (Head, Chest) of the predicate device, with scanogram ranges displayed according to the selected protocol.
The provided FDA 510(k) Clearance Letter for SCENARIA View Phase 5.0 primarily focuses on demonstrating substantial equivalence to a predicate device (SCENARIA View 4.2). The document outlines non-clinical and some clinical tests, but it does not present a formal "acceptance criteria" table with specific quantitative metrics for the device performance of the new AI features (AutoPose, Body Still Shot) in the same way one might find for a novel AI/CADe device.
The "acceptance criteria" for this submission appear to be centered around workflow improvement and sufficient image quality when compared to manual or predicate methods, rather than hard quantitative performance targets. The study designs are more akin to usability studies and qualitative image reviews.
Here's an attempt to extract and interpret the information based on your requested structure, acknowledging the limitations of the provided text in terms of explicit acceptance criteria and standalone performance metrics for the AI components.
Acceptance Criteria and Device Performance for SCENARIA View Phase 5.0 (AI Components)
The provided document describes the acceptance criteria and study results for the new features AutoPose and Body Still Shot introduced in the SCENARIA View Phase 5.0 system. The acceptance criteria are largely qualitative, focusing on workflow improvement and sufficient image quality.
1. Table of Acceptance Criteria and Reported Device Performance
| Feature/Metric | Acceptance Criteria (Implied) | Reported Device Performance |
|---|---|---|
| AutoPose | Reduce the number of steps in the scan range setting procedure compared to conventional manual operation. | All evaluated cases (across all regions) showed a reduction in the number of steps compared to manual scan range setting. Max manual adjustment steps (if needed) remained equivalent. |
| Body Still Shot | Able to obtain images of sufficient quality with reduced motion artifacts. | Images reconstructed with and without Body Still Shot were reviewed, and the function was evaluated to be able to obtain images of sufficient quality. (No specific quantitative metric for "sufficient quality" is provided, implying qualitative assessment). |
Note on "Acceptance Criteria": The document does not explicitly list quantitative acceptance criteria in a table format for the AI features. The criteria listed above are inferred from the Methods and Results sections of the non-clinical and clinical tests described. The primary goal was to demonstrate workflow efficiency (AutoPose) and qualitative image improvement (Body Still Shot).
2. Sample Sizes and Data Provenance
-
AutoPose (Clinical Test):
- Total Cases: 50 (Head), 50 (Neck), 52 (Chest), 54 (Heart), 52 (Abdomen), 52 (Abdomen-Pelvis), 50 (Chest-Abdomen), 24 (T-L-Spine), 50 (C-Spine), 50 (T-Spine), 50 (L-Spine).
- Note: The table layout in the original document makes it unclear if Chest-Upper Abdomen had cases listed, but it's empty. Assuming 50 for Chest-Abdomen and 0 for Chest-Upper Abdomen as it's not specified.
- Total Sum (if all distinct): 50 + 50 + 52 + 54 + 52 + 52 + 50 + 50 + 50 + 50 + 24 = 504 cases.
- Data Provenance: Clinical sites in the USA.
- Retrospective/Prospective: Not explicitly stated, but the nature of evaluating steps in a procedure suggests it was likely a prospective workflow evaluation with certified technologists.
- Total Cases: 50 (Head), 50 (Neck), 52 (Chest), 54 (Heart), 52 (Abdomen), 52 (Abdomen-Pelvis), 50 (Chest-Abdomen), 24 (T-L-Spine), 50 (C-Spine), 50 (T-Spine), 50 (L-Spine).
-
Body Still Shot (Clinical Test):
- Total Cases: Not specified.
- Data Provenance: Not specified (only mentions "Japanese M.D." reviewers).
- Retrospective/Prospective: Not specified.
-
Training Set Sample Size:
- Not disclosed in the provided document. The document primarily details the validation/test set.
3. Number of Experts and Qualifications for Ground Truth
-
AutoPose (Clinical Test):
- Number of Experts: Not explicitly stated how many "certified radiological technologists" performed the evaluations, only that they were certified.
- Qualifications: "certified radiological technologists." No specific years of experience or other details are provided.
- Role in Ground Truth: Their assessment of the number of steps and the "expected position" for manual adjustment served as the comparison for AutoPose's performance.
-
Body Still Shot (Clinical Test):
- Number of Experts: Not explicitly stated how many "Japanese M.D." (Medical Doctors) reviewed the images, only that they were "Japanese M.D."
- Qualifications: "Japanese M.D." No specific specialty (e.g., radiologist), years of experience, or other details are provided.
- Role in Ground Truth: Their qualitative review ("evaluated to be able to obtain images of sufficient quality") served as the ground truth for image quality.
4. Adjudication Method for the Test Set
- AutoPose: Not explicitly stated. The results imply a direct comparison of workflow steps, but it's not mentioned if multiple technologists evaluated the same cases or how discrepancies were handled.
- Body Still Shot: Not explicitly stated how reviews were conducted if multiple M.D.s were involved (e.g., consensus, majority vote).
5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study
- Was it done?: No, a formal MRMC comparative effectiveness study demonstrating how human readers improve with AI vs. without AI assistance was not performed or reported for either AutoPose or Body Still Shot.
- Effect Size: Not applicable, as no such study was presented. The studies were focused on workflow efficiency (AutoPose) and qualitative image quality (Body Still Shot).
6. Standalone (Algorithm Only) Performance
- Was it done?: The document does not describe a standalone AI performance study (e.g., precision, recall, F1-score for AutoPose's pose recognition; or a quantitative image quality metric for Body Still Shot). The evaluation of AutoPose was focused on the workflow impact, and Body Still Shot on perceived image quality by human reviewers.
7. Type of Ground Truth Used
- AutoPose:
- For Scan Range Setting: The "ground truth" or reference for the AutoPose evaluation was the manual scan range setting process and the expected optimal scan position as determined by certified radiological technologists. The metric was a reduction in the number of workflow steps.
- Body Still Shot:
- For Image Quality: The ground truth for image quality was based on the qualitative assessment and review by "Japanese M.D." to determine "sufficient quality." This is essentially expert consensus on image usability.
8. Sample Size for the Training Set
- The document does not provide information on the sample size used for training the AI models (AutoPose and Body Still Shot).
9. How Ground Truth for the Training Set was Established
- The document does not provide information on how the ground truth for the training set was established for the AI models.
Ask a specific question about this device
Page 1 of 6