    K243682
    Device Name
    SonoPlex STIM; SonoPlex II
    Manufacturer
    PAJUNK GmbH Medizintechnologie
    Date Cleared
    2025-06-27

    (210 days)

    Product Code
    BSP
    Regulation Number
    868.5150
    Why did this record match?
    Search-Everything :

    Matched: '868.5150'

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    SonoPlex STIM and SonoPlex II Needles equipped with Cornerstone reflectors are used to puncture the tissue in order to gain entry and inject local anesthetics to induce regional anesthesia. An electrical stimulus may be applied to the needle via a cable and connector to assist the physician pinpoint the area of application.
    Device Description
    The subject device, the SonoPlex STIM and SonoPlex II nerve block needle is a single-use anesthesia conducting needle intended to gain entry or puncture the tissue and inject anesthetics to induce regional anesthesia. The SonoPlex STIM and SonoPlex II needle is intended for use under ultrasound guidance. Visibility under ultrasound is enhanced by CornerStone reflectors as cleared by FDA in several Premarket Notification Submissions. The SonoPlex STIM and SonoPlex II needle is equipped with an connecting cable, injection tube and NanoLine® coating (Parylene, no nanomaterials incorporated). The distal connection of the tube is either equipped with a LUER Connector according to ISO 80369-7 or a NRFit-Connector according to ISO 80369-6. The device in focus is a single use device and has an intended time of use up to 24 hours acc. EO-residuals acc. DIN EN ISO 10993-7. The standard time of use is less than 60 minutes. The SonoPlex STIM and SonoPlex II cannulas are not for intrathecal use. The SonoPlex STIM and SonoPlex II cannulas are produced at PAJUNK® GmbH Medizintechnologie in Geisingen, Germany.
    Ask a Question
    K Number
    K250774
    Device Name
    SPROTTE® STANDARD (LUER/ NRFit®) Lumbar Puncture
    Manufacturer
    PAJUNK GmbH Medizintechnologie
    Date Cleared
    2025-06-25

    (103 days)

    Product Code
    BSP
    Regulation Number
    868.5150
    Why did this record match?
    Search-Everything :

    Matched: '868.5150'

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The SPROTTE® STANDARD (LUER/ NRFit®) lumbar puncture needles are intended to gain entry into or puncture the spinal cavity permitting injection/ withdrawal of fluids for purposes of diagnostic lumbar puncture, myelography/ discography.
    Device Description
    The subject device, the SPROTTE® STANDARD (LUER/ NRFit®) anaesthesia conduction needle is a single-use anaesthesia conducting intended for administer anesthetic agent to the spinal space. The SPROTTE® cannulas are equipped with a stylet as well as optional with an Introducer. It is available with a LUER respectively with a NRFit® hub. The LUER is either a standard hub, a magnifying hub or a 2.G hub. The cannula tube is straight. The distal connection of the hub is either equipped with a LUER Connector according to ISO 80369-7 or a NRFit-Connector according to ISO 80369-6.
    Ask a Question
    K Number
    K243525
    Device Name
    SonoTAP and SonoTAP II
    Manufacturer
    PAJUNK GmbH Medizintechnologie
    Date Cleared
    2025-03-24

    (130 days)

    Product Code
    BSP
    Regulation Number
    868.5150
    Why did this record match?
    Search-Everything :

    Matched: '868.5150'

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The SonoTAP and SonoTAP II anaesthesia conduction needles enhanced for ultrasound visibility are intended for the transient delivery of anesthetics to provide regional anesthesia and analgesia.
    Device Description
    The subject device, the SonoTAP II needles are single-use anaesthesia conducting needles intended for the transient delivery of anesthetics to provide regional anesthesia and analgesia. The SonoTAP and SonoTAP II needles are intended for use under ultrasound guidance. Visibility under ultrasound is enhanced by CornerStone reflectors as cleared by FDA in several Premarket Notification Submissions. The SonoTAP and SonoTAP II needles is equipped with an injection tube. The distal connection of the tube is either equipped with a LUER Connector according to ISO 80369-7 or a NRFit-Connector according to ISO 80369-6. The device in focus is a single use device and has an intended time of use up to 24 hours acc. EO-residuals acc. DIN EN ISO 10993-7. The standard time of use is less than 60 minutes. The SonoTAP and SonoTAP II cannulas are not for intrathecal use.
    Ask a Question
    K Number
    K241953
    Device Name
    SPROTTE® STANDARD (LUER/ NRFit®) Anesthesiology
    Manufacturer
    PAJUNK GmbH Medizintechnologie
    Date Cleared
    2024-11-22

    (142 days)

    Product Code
    BSP
    Regulation Number
    868.5150
    Why did this record match?
    Search-Everything :

    Matched: '868.5150'

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The SPROTTE® STANDARD (LUER/ NRFit®) needles are anesthesia conduction needles which are used to administer anesthetic agent to the subarachnoid space.
    Device Description
    The subject device, the SPROTTE® STANDARD (LUER/ NRFit®) anaesthesia conduction needle is a single-use anaesthesia conducting intended for administer anesthetic agent to the subarachnoid space. The SPROTTE® cannulas are equipped with a stylet as well as optional with an Introducer. It is available with a LUER respectively with a NRFit® hub. The LUER is either a standard hub, a magnifying hub or a 2.G hub. The cannula tube is straight. The distal connection of the hub is either equipped with a LUER Connector according to ISO 80369-7 or a NRFit-Connector according to ISO 80369-6.
    Ask a Question
    K Number
    K241954
    Device Name
    SonoBlock; SonoBlock II
    Manufacturer
    PAJUNK GmbH Medizintechnologie
    Date Cleared
    2024-09-11

    (70 days)

    Product Code
    BSP
    Regulation Number
    868.5150
    Why did this record match?
    Search-Everything :

    Matched: '868.5150'

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    SonoBlock and SonoBlock II Needles equipped with Cornerstone reflectors are used to puncture the tissue in order to gam entry and inject local anaesthetics to induce regional anaesthesia. Warning: SonoBlock and SonoBlock II Needles are not intended for RF ablation or any other type of ablation procedure.
    Device Description
    The subject device, the SonoBlock II nerve block needle is a single-use anaesthesia conducting nerve block needle intended for performing peripheral nerve blocks. The SonoBlock and SonoBlock II nerve block needle is intended for use under ultrasound guidance. Visibility under ultrasound is enhanced by CornerStone reflectors as cleared by FDA in several Premarket Notification Submissions.
    Ask a Question
    K Number
    K240253
    Device Name
    Reach Needle
    Manufacturer
    Aerin Medical Inc.
    Date Cleared
    2024-03-21

    (51 days)

    Product Code
    BSP
    Regulation Number
    868.5150
    Why did this record match?
    Search-Everything :

    Matched: '868.5150'

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The Reach Needle is used for in injecting local anesthetics into a patient to provide regional anesthesia.
    Device Description
    The Reach Needle is a sterile, single use, 4-inch-long needle used for administering anesthetic solutions for regional anesthesia. The Reach Needle is 27-qauge needle that is reinforced to reduce needle flex during administration of anesthesia solutions. The needle tip is a short bevel quincke style tip that extends approximately 2mm past the reinforcing shaft, providing a distal stop for consistent injection depth. The distal end of the needle has a slight bend to help access difficult to reach areas such as nasal anatomy. The needle hub is compatible with luer lock connectors. The Reach Needle is intended for use in adults (≥ 22 years).
    Ask a Question
    K Number
    K212982
    Device Name
    Medispine - Spinal Needle, Glospine - Spinal Needle
    Manufacturer
    Global Medikit Limited
    Date Cleared
    2022-07-29

    (315 days)

    Product Code
    BSP
    Regulation Number
    868.5150
    Why did this record match?
    Search-Everything :

    Matched: '868.5150'

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    Spinal Needle (Quincke Bevel and Pencil Point) is intended for injection of local anesthetics into the subarachnoid space to provide spinal anesthesia for pain management. The device is intended to be used in a professional healthcare environment and not tested for MRI safety.
    Device Description
    Spinal Needles are long, flexible needles of small gauge (typically 18G to 27G) which are available with different types of tips: Pencil point and Quincke bevel. The Spinal Needles are available in a series of combination of needle size and length. The smaller size needles of Pencil point tip are provided with introducer needles to provide support for accessing the tough tissues. Spinal needles have a removable stylet that completely occludes the lumen to avoid block. The stylet is withdrawn after the spinal anesthesia needle has penetrated into the subarachnoid space for injecting anesthetic. The needle hub is luer connector (6% luer taper).
    Ask a Question
    K Number
    K211085
    Device Name
    BD Perisafe Tuohy Epidural Needle, BD Perisafe Weiss Epidural Needle
    Manufacturer
    Becton, Dickinson and Company
    Date Cleared
    2022-07-01

    (445 days)

    Product Code
    BSP
    Regulation Number
    868.5150
    Why did this record match?
    Search-Everything :

    Matched: '868.5150'

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    BD Perisafe™ Tuohy Epidural Needle and BD Perisafe™ Weiss Epidural Needle are indicated for the administration of anesthesia or analgesia into the epidural space, or to introduce a dedicated catheter for continuous administration of anesthesia or analgesia into the epidural space. They can also be used to introduce a spinal needle to perform a combined spinal and epidural procedure. These devices are intended for adult and pediatric patients.
    Device Description
    BD Perisafe™ Tuohy Epidural Needle and BD Perisafe™ Weiss Epidural Needle are single use, sterile needles which incorporate an ISO 594-1/-2 compliant connector. The needles are also available in bulk, non-sterile configurations (to be sterilized prior to use). Each type of needle consists of a hollow, stainless steel cannula, a translucent, polypropylene hub and a polypropylene shield over the needle. The cannula is bonded to the hub at one end. The BD Perisafe™ Epidural needles also contain a plastic stylet handle and are available in various needle lengths. The needle hubs are ISO 594-1 and ISO 594-2 compliant connectors. The stylet handle for the BD Perisafe™ Epidural needles is color coded and correlate to the gauge size per ISO 6009:2016.
    Ask a Question
    K Number
    K210978
    Device Name
    BD Quincke Spinal Needle, BD Whitacre Spinal Needle, BD Spinal Introducer Needle
    Manufacturer
    Becton, Dickinson and Company
    Date Cleared
    2021-12-22

    (265 days)

    Product Code
    BSP
    Regulation Number
    868.5150
    Why did this record match?
    Search-Everything :

    Matched: '868.5150'

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The BD™ Spinal Needles are intended to gain entry into or puncher the spinal cavity permitting injection (including anesthesia)/withdrawal of fluids for purposes of diagnostic lumbar puncture and myelography procedures. This device is intended for adult and pediatric patients. The BD™ Spinal Introducer Needle is intended for placement or introduction of spinal needles. This device is intended for adult and pediatric patients.
    Device Description
    The BD Quincke Spinal Needle, BD Whitacre Spinal Needle are available in various gauges and needle lengths. The needle consists of a hollow needle (cannula) bonded to a clear hub at one end and a specific needle-point type (Quincke or Whitacre) at the other end. The stylet has a handle, which is color-coded and correlates to the gauge size. The BD Spinal Needle Introducer consists of a needle, needle hub and needle shield and is available in various gauges. The needle consists of a hollow needle (cannula) bonded to a translucent colored hub (per gauge) at one end and a specific needle-point type at the other end. The introducer needle is optional aid through which a spinal needle can be inserted. The BD Quincke Spinal Needle, BD Whitacre Spinal Needle and BD Spinal Needle Introducer devices are single use, sterile needles which, incorporate the ISO 594-1 and ISO 594-2 compliant connector. The needles are also available in bulk, non-sterile configurations (to be sterilized prior to use).
    Ask a Question
    K Number
    K203668
    Device Name
    RELI NRFit Epidural Needles, Phoenix NRFit Epidural Needles, RELI NRFit Spinal Needles, Phoenix NRFit Spinal Needles
    Manufacturer
    MYCO Medical Supplies, Inc.
    Date Cleared
    2021-09-29

    (287 days)

    Product Code
    BSP
    Regulation Number
    868.5150
    Why did this record match?
    Search-Everything :

    Matched: '868.5150'

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    Spinal and Epidural needles are to be used to inject local anesthetics into a patient to provide regional anesthesia.
    Device Description
    RELI® NRFit® Spinal Needles, RELI® NRFit® Epidural Needles, Phoenix NRFit® Spinal Needles, and Phoenix NRFit® Epidural Needles are intended to be used for injection of local anesthetics into a patient to provide regional anesthesia. The Spinal and Epidural needles are supplied in bulk nonsterile, or sterile by ethylene oxide gas in peel open packages and are intended for one-time use. The RELI® NRFit® Spinal Needles, RELI® NRFit® Epidural Needles, Phoenix NRFit® Spinal Needles, and Phoenix NRFit® Epidural Needles feature an ISO 80369-6 compliant connector that is about 20% smaller than the predicate device. The ISO 80369-6 hub design reduces the risk of cross connection when used with luer connectors developed under the same series of standards. RELI® NRFit® Spinal Needles and Phoenix NRFit® Spinal Needles are composed of a stainless-steel cannula and stylet, a hub, and plunger. The spinal needle is supplied with either the Quincke Point (K-3 Point) or the Pencil Point tip configuration. Quincke point spinal needles feature fitted, close tolerance stylet and cannula bevel to minimize coring and trauma; large clear hubs for enhanced tactile feel and visualization of CSF; color coded stylet hub to easily identify gauge size; some sizes are also available with short bevel. Available in sterile and non-sterile packaging. Pencil point spinal needles feature an atraumatic point with side-port dispensing to reduce loss of CSF; large clear hubs for enhanced tactile feel and visualization of CSF; color coded stylet hub to easily identify gauge size. Some sizes are available with tapered design to counter bending and minimize flexing during insertion. Available in sterile and non-sterile packaging. The RELI® NRFit® Epidural Needles and Phoenix NRFit® Epidural Needles are composed of a stainlesssteel cannula, a polycarbonate hub and detachable wing, a stainless-steel stylet and plunger as Tuohy (Huber point) tip configuration in various needle gauge sizes and lengths. Epidural needles feature large clear hub for enhanced tactile feel; wide metric marking for maximum visibility and accuracy in placement; color coded stylet/hub to identify needle gauge size. Epidural needles are available in sterile and non-sterile packaging.
    Ask a Question