510(k) Data Aggregation

    Why did this record match?
    Reference Devices :

    K132951, K130885, K132119

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The MAGNETOM systems are indicated for use as magnetic resonance diagnostic devices (MRDD) that produce transverse, sagittal, coronal and oblique cross sectional images, spectroscopic images and or spectra, and that display the internal structure and/or function of the head, body or extremities.

    Other physical parameters derived from the images and/or spectra may also be produced. Depending on the region of interest, contrast agents may be used. These images and the physical parameters derived from the inages and/or spectra when interpreted by a trained physician, yield information that may assist in diagnosis.

    The MAGNETOM systems described above may also be used for imaging during interventional procedures when performed with MR compatible devices such as in-room display and MR-Safe biopsy needles.

    Device Description

    The subject device, synqo MR E11B system software, is being made available for the following MAGNETOM MR Systems:

    • MAGNETOM Aera (24-channel configuration), .
    • MAGNETOM Avanto™ ●
    • MAGNETOM Skyra™, ●
    • . MAGNETOM Prisma and
    • . MAGNETOM Prisma™

    Two new coils, Body 30/60 and Body 6 long, will be available for the subject device systems. The feature FREEZEit will be extended to other body regions. In addition to the abdomen region, FREEZEit will be extended to other regions such as the head, head and neck, pelvis, and chest region. . The syngo MR E11B SW also includes new sequences as well as minor modifications of already existing features. A high level summary of the new sequences can be viewed below:

    DSI
    With software version syngo MR E11B Siemens offers DSI for MAGNETOM Prisma, Prismall and Skyra" systems. The DSI option allows diffusion-weighted images to be acquired according to a DSI-compatible q-space sampling scheme.

    QISS evaluation
    QISS (Quiescent-Interval Single-Shot) MR Angiography is a technique for non-contrastenhanced MR Angiography (non-CEMRA) that is particularly suited for examinations of patients with PAD. Since patients with PAD may also suffer from additional impairments such as renal dysfunction, the administration of contrast agent may often be unadvisable in this patient group. Siemens provides a manageable and optimized QISS workflow for imaging peripheral arteries, which can be easily adapted by the customer based on the patient's needs.

    A new "Dot Engine" is provided to ease MRI acquisitions in Radiation Therapy.

    RT Dot Engine
    RT Dot Engine is a new Dot Engine for aiding in Radiation Therapy planning. The RT Dot Engine does not provide new functionality, but collects and displays existing system information for the user. The RT Dot Engine comprises existing protocols, enhanced with the RT Planning Dot Add-in and the "MPR Planning" interaction step. The RT (Radiation Therapy) Dot Engine is used to ease MRI acquisitions of the head and the head/neck region with stereotactic frames or mask-based fixation techniques. RT Dot Engine is a workflow solution for acquiring MR images intended to aid in Radiation Therapy Planning. RT Dot engine helps streamline acquisition of MR images to be used along with any RT planning software that uses MR images in addition to CT images.

    AI/ML Overview

    The provided text is a 510(k) summary for a medical device and does not contain the level of detail typically found in a clinical study report regarding acceptance criteria and performance studies for an AI-powered device.

    This document describes a Magnetic Resonance Diagnostic Device (MRDD) software upgrade (syngo MR E11B) for existing Siemens MAGNETOM MR systems. The submission is a 510(k) premarket notification, which seeks to demonstrate substantial equivalence to a legally marketed predicate device, rather than proving performance against specific acceptance criteria for a novel AI algorithm.

    Therefore, many of the requested details about acceptance criteria, clinical study design, sample sizes, ground truth establishment, and expert adjudication are not present in this type of regulatory document.

    However, I can extract the information that is available and clarify what is missing based on the context of a 510(k) submission for an MRI system software upgrade:

    1. A table of acceptance criteria and the reported device performance

    Acceptance CriteriaReported Device Performance (Summary)
    Safety and EffectivenessThe device performs as intended and is substantially equivalent to predicate devices. Risk management followed ISO 14971:2007. Adherence to IEC 60601-1 series to minimize electrical and mechanical risk. Conforms to applicable FDA recognized and international IEC, ISO, and NEMA standards.
    Technological CharacteristicsSame technological characteristics as predicate device systems (K141977). Substantially equivalent in acquiring MR images steps/features, operational environment, programming language, operating system, and performance. Conforms to IEC 62304:2006 for software medical devices and IEC/NEMA standards.
    New Coils (Body 30/60, Body 6 long)Coils tested for SNR, image uniformity, and heating. Clinical images provided to support new coils.
    New/Modified Sequences & AlgorithmsDedicated phantom testing conducted for particular new sequences (e.g., DSI, QISS, RT Dot Engine). Acoustic noise measurements performed for quiet sequences. Image quality assessments completed; comparisons made to predicate features where applicable. Clinical images provided to support new software features.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample Size for Test Set: Not explicitly stated as a formal "test set" in the context of an algorithm evaluation. The document mentions "clinical images were provided to support the new coils as well as the new software features," but the number of images or patients is not specified.
    • Data Provenance: Not specified. Given the nature of a 510(k) for a software upgrade to an MRI machine, the "clinical images" likely came from internal testing or routine clinical acquisitions.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • The document states "These images and the physical parameters derived from the images and/or spectra when interpreted by a trained physician, yield information that may assist in diagnosis." However, it does not specify the number or qualifications of experts used to establish a formal ground truth for testing the software's performance, as this is an MRI system software upgrade, not a diagnostic AI algorithm.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • No adjudication method is mentioned.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No MRMC study was conducted or reported. This device is a software upgrade for an MRI system, not an AI diagnostic assistant tool.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    • Not applicable in the context of this device. The software "produces transverse, sagittal, coronal and oblique cross sectional images, spectroscopic images and or spectra," which are then "interpreted by a trained physician." It is not a standalone diagnostic algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    • For the nonclinical tests (SNR, uniformity, heating, acoustic noise), the "ground truth" would be established by technical specifications and phantom measurements.
    • For image quality assessments, a "ground truth" (e.g., against specific diagnostic findings) is not detailed. The assessment likely involved expert review of image quality (e.g., resolution, artifact reduction, diagnostic clarity) rather than a comparison to a definitive clinical ground truth established by pathology or long-term outcomes. The primary focus is on demonstrating that the images produced are diagnostically acceptable and equivalent to the predicate.

    8. The sample size for the training set

    • Not applicable. This document describes a software upgrade for an MRI system, which includes new sequences and features (e.g., DSI, QISS, RT Dot Engine). It is not an AI algorithm that would typically have a "training set" in the machine learning sense. The software development follows traditional engineering and quality assurance practices.

    9. How the ground truth for the training set was established

    • Not applicable, as no training set (in the AI/ML context) is mentioned for this device.
    Ask a Question

    Ask a specific question about this device

    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The MAGNETOM systems described above are indicated for use as a magnetic resonance diagnostic device (MRDD) that produces transverse, sagittal, coronal and oblique cross sectional images and/or spectra, and that displays the internal structure and/or function of the head, body, or extremities.

    Other physical parameters derived from the images and/or spectra may also be produced. Depending on the region of interest, contrast agents may be used. These images and/or spectra and the physical parameters derived from the images and/or spectra when interpreted by a trained physician vield information that may assist in diagnosis.

    The MAGNETOM systems described above may also be used for imaging during interventional procedures when performed with MR compatible devices such as in-room display and MR-Safe biopsy needles.

    Device Description

    The subject device, software syngo MR E11A for MAGNETOM Aera and MAGNETOM Skyra offers two new applications, LiverLab (an application of non-invasive liver evaluation) and MyoMaps (an application designed to provide a means to generate pixel maps for myocardial MR relaxation times). In addition, software syngo MR E11A makes the Dot Cockpit available for the user to modify and create Siemens Dot Engine workflows in a very intuitive way which supplements some of the support of an application specialist. The software syngo MR E11A also includes new and modified sequences as well as minor modifications of already existing features. In additional coils are offered and some hardware components have been modified.

    Siemens Medical Solutions, USA Inc., intends to market MAGNETOM Aera and MAGNETOM Skyra with new software, syngo MR E11A. While syngo MR E11A offers additional capabilities with respect to the predicate device, the MAGNETOM Aera and MAGNETOM Skyra have the same technological characteristics as the predicate device (K121434; Cleared November, 5, 2012).

    Furthermore, Siemens Medical Solutions, USA Inc., intends to market a new configuration of the MAGNETOM Skyra with 24 receive channels with software syngo MR E11A.

    The MAGNETOM Aera and MAGNETOM Skyra will be offered ex-factory (new production) as well as in-field upgrades for the currently installed MAGNETOM Aera and MAGNETOM Skyra systems. The new MAGNETOM Skyra configuration with 24 receive channels will be offered as an ex-factory option (new production).

    AI/ML Overview

    This FDA 510(k) summary describes a new software version (syngo MR E11A) for existing Siemens MAGNETOM Aera and MAGNETOM Skyra MRI systems. The primary focus of the document is to demonstrate substantial equivalence to previous versions and other cleared devices, rather than establishing new acceptance criteria for a novel device.

    Therefore, the requested information regarding acceptance criteria, device performance, and specific study details (like sample size for test sets, expert qualifications, and adjudication methods) is largely not present for the overall system or its new features as this is an equivalence submission. The closest equivalent to "acceptance criteria" are the results of performance tests demonstrating the device performs as intended and is "substantially equivalent."

    However, I can extract the available information regarding testing for the new features:

    1. Table of Acceptance Criteria and Reported Device Performance

    Feature/TestAcceptance Criteria (Implied)Reported Device Performance
    New CoilsPerform as intended with appropriate SNR, image uniformity, and heating levels.Tested for SNR, image uniformity, and heating. The results demonstrated the device performs as intended.
    New/Modified Sequences & AlgorithmsPerform as intended; maintain or improve image quality compared to predicate features.Dedicated phantom testing conducted. Image quality assessments completed. In some cases, image quality was compared. The results demonstrated the device performs as intended.
    Quiet SequencesMeet specified acoustic noise levels.Acoustic noise measurements performed. The results demonstrated the device performs as intended.
    LiverLab (non-invasive liver evaluation)Functional and accurate, potentially comparable to existing methods.Validated with volunteer and phantom scans, and synthetic raw data. The results demonstrated the device performs as intended.
    MyoMaps (myocardial MR relaxation times)Functional and accurate.Tested on volunteers after ECGs were applied. Compared to Thalassaemia Tools in a 100-person study. The results demonstrated the device performs as intended.
    All other software featuresVerified and validated as functional and safe.Verified and validated. The results demonstrated the device performs as intended.
    Overall System ComplianceConform to relevant standards (IEC 62304:2006, IEC, NEMA, ISO 14971:2007).Conforms to IEC 62304:2006, IEC, NEMA standards. Risk management in compliance with ISO 14971:2007.

    2. Sample size used for the test set and the data provenance

    • MyoMaps Comparison Study:
      • Sample Size: 100 persons.
      • Data Provenance: Not specified, but involved "volunteers."
    • LiverLab Validation:
      • Sample Size: Not specified beyond "volunteer" and "phantom scans."
      • Data Provenance: Not specified, beyond "volunteer" and "phantom scans" and "synthetic raw data."
    • New Coils, Sequences, Algorithms, Acoustic Noise: Sample sizes not specified; phantom testing mentioned.
    • Clinical tests (overall device): No clinical tests were conducted to support the substantial equivalence argument beyond the provision of clinical images to support new coils and software features.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • This information is not provided in the document. The document states that the images and spectra, "when interpreted by a trained physician, yield information that may assist in diagnosis." However, for validation studies, the specifics of expert involvement or ground truth establishment are not detailed.

    4. Adjudication method for the test set

    • This information is not provided in the document.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • A MRMC study comparing human readers with and without AI assistance was not mentioned or performed as part of this submission. The "MyoMaps" feature was compared to "Thalassaemia Tools," which is a comparison of two tools, not a human-AI comparison.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done

    • The document describes "LiverLab" validation using "volunteer as well as phantom scans, and synthetic raw data" and "MyoMaps" being "tested on volunteers." This suggests standalone performance evaluation for these specific features. However, detailed metrics of standalone performance are not provided, only that the "results... demonstrate that the device performs as intended."

    7. The type of ground truth used

    • MyoMaps: The comparison was against "Thalassaemia Tools." For the "volunteers" testing, the method of establishing ground truth for myocardial MR relaxation times beyond direct measurement is not specified.
    • LiverLab: Validation involved "volunteer as well as phantom scans, and synthetic raw data." The ground truth for phantom scans would be known parameters. For volunteer scans, the ground truth source for liver evaluation is not explicitly stated (e.g., biopsy results, clinical diagnosis).
    • For other features (coils, sequences), the ground truth generally relies on physical measurements and expected image properties.

    8. The sample size for the training set

    • This information is not provided in the document. The submission focuses on verification and validation of implemented features rather than detailing the development or training of algorithms.

    9. How the ground truth for the training set was established

    • This information is not provided in the document. Given that details on a training set are absent, the method for establishing its ground truth is also not mentioned.
    Ask a Question

    Ask a specific question about this device

    Page 1 of 1