510(k) Data Aggregation

    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Simply Iconic™ dental implants are two-piece implants for one-stage surgical procedures. These implants are intended for use in partially and fully edentulous upper and lower jaws in support of single or multiple-unit restorations and termediate abutment support for fixed bridgework. Implants can be indicated for immediate loading when stability has been achieved and with appropriate occlusal loading.

    Legacy2, simplyLegacy2, Legacy3, simplyLegacy3, and Legacy4 dental implants are two-piece implants for one-stage or twostage surgical procedures. These implants are intended for use in partially and fully edentulous upper and lower jaws in support of single or multiple-unit restorations and terminal or intermediate abutment support for fixed bridgework. Implants can be indicated for immediate loading when good primary stability has been achieved and with appropriate occlusal loading. The Legacy 2, Legacy3, and Legacy4 fixture-mounts are intended for use with the corresponding dental implants (Legacy3, and Legacy4, respectively). The fixture-mounts can function as an abutment, fixture-mounts are intended for use with dental implants in the maxillary and/or mandbular arches to provide support for crowns or bridges for edentulous or partially edentulous patients.

    Custom Titanium Abutments are customizable devices intended for use with dental implants in the maxillary and or mandibular arches to provide support for crowns or bridges for edentulous or partially edentulous patients.

    The Legacy™ SMARTBase Abutment system is designed to be used in support of a dental implant(s) to provide support for prosthetic restorations in a partially edentulous patient. Legacy SMARTBase engaging abutments are intended for use in the mandible or maxilla in support of single unit restorations.

    InterActive/SwishActive Implant System consists of two-piece implants for one-stage surgical procedures. These implants are intended for use in partially and fully edentulous upper and lower jaws in support of single or multiple-unit restorations and terminal or internediate SMARTBase support for fixed bridgework.

    Implant Direct Custom Bars are patient specific devices indicated for attachment to dental implants in the treatment of partially or fully edentulous jaws for the purpose of restoring chewing function.

    GPS® Angled Abutments are designed to be used in support of a dental implant(s) to provide support for prosthetic restorations in a partially or completely edentulous patient. These abutments are designed to only receive a fabricated multi-unit bridge or overdenture. Abutments are intended for use in the mandible or maxilla. Implants can be indicated for immediate loading when good primary stability has been achieved and with appropriate occlusal loading.

    InterActive/SwishActive Implant System consists of two-piece implants for one-stage surgical procedures. These implants are intended for use in partially and fully edentulous upper and lower jaws in support of single or multipleunit restorations and terminal or intermediate abutment support for fixed bridgework. Implants can be indicated for immediate loading when good primary stability has been achieved and with appropriate occlusal loading.

    Legacy3 6mm Length consists of two-piece implants for one-stage or two-stage surgical procedures. There implants are intended for use in partially and fully edentulous upper and lower jaws in support of single or multiple-unit restorations and terminal or internediate abutment support for fixed bridgework. Implants can be indicated for immediate loading when good primary stability has been achieved and with appropriate occlusal loading.

    InterActive/SwishPlus2 Implant System consists of two-piece implants for one-stage or two-stage surgical procedures. These implants are intended for use in partially and fully edentulous upper and lower jaws in support of single or multiple-unit restorations and terminal or intermediate abutment support for fixed bridgework: Implants can be indicated for immediate loading when good primary stability has been achieved and with appropriate occlusal loading.

    Spectra-System Dental Implants 2008 are comprised of dental implant fixtures and prosthetic devices that compose a two-piece implant system. The implants are intended for use in the mandible and maxilla, in support of single unit or multiple unit cement or screw-receiving restorations and for the retention and support of overdentures. The implants are intended for immediate placement and function for the support of single-tooth restorations, recognizing bone stability and appropriate occlusal load requirements.

    The SwissPlant Dental Implant system consists of two-piece implants for one or two-stage surgical procedures that are intended for use in partially or fully edentulous maxillae, in support of single or multiple-unit restorations including: cement retained, screw retained or overdenture restorations and in terminal or immediate abutment support for fixed bridgework. The SwissPlant dental implants are intended for immediate placement and function on single tooth and/or multiple tooth applications recognizing initial implant stability and appropriate occlusal loading, to restore normal masticatory function.

    Spectra-System Abutments are designed to be used in support of a dental implant(s) to provide support for prosthetic restorations such as crowns, bridges, overdentures or custom prosthetic fabrications in a partially or completely edentulous patient. Spectra-System Abutments are intended for use in the mandble or maxilla. Prostheses can be screw or cement retained to the abutment.

    The ReActive Dental Implant System are dental implant fixtures that are a part of a two-piece implant system. The ReActive implants are intended for use in the mandible and maxilla, in support of single or multiple-unit cement or screw receiving fixed restorations and for retention and support of overdentures. The implants are intended for immediate placement and function for support of single tooth and/or multiple tooth restorations, recognizing bone stability and appropriate occlusal load requirements.

    ScrewIndirect Narrow Dental Implants for single-stage surgical procedures intended for use in partially or fully edentulous mandibles and maxillae, in support of complete or partial denture prostheses or as a terminal or intermediary attachment for fixed or removable bridgework via interface with copings. These implants are intended for for support of splinted multiple tooth restorations, provided initial implant stability and appropriate occlusal load requirements are met.

    The RePlus Dental Implants with HA coating are dental implant fixtures that are a part of a two-piece implant system. The RePlus implants are intended for use in the mandible and maxilla, in support of single or multiple-unit cement or screw receiving fixed restorations and for retention and support of overdentures. The immediate loading for support of single tooth and/or multiple tooth restorations, provided initial implant stability and appropriate occlusal load requirements are met.

    The ScrewPlus Dental Implant with HA coating is a dental implant fixture that is a part of a two-piece implant system that is to be used for single-stage or two-stage surgical procedures. The ScrewPlus implants are intended for use in the mandible and maxilla, in support of single or multiple-unit cement or screw receiving fixed restoration and support of overdentures. The implants are intended for immediate placement and function for multiple tooth and/or multiple tooth restorations, recognizing bone stability and appropriate occlusal load requirements.

    The Legacy Dental Implant with HA coating is a dental implant fixture that is a part of a two-piece implant system. The Legacy implants are intended for use in the mandible and maxilla, in support of single or multiple-unit cement or screw receiving fixed restorations and for retention and support of overdentures. The implants are intended for immediate placement and function for support of single tooth and/or multiple tooth restorations, recognizing bone stability and appropriate occlusal load requirements.

    The Spectra Dental Implant System consists of one-piece implants for single-stage or two- stage surgical procedures that are intended for use in partially or fully edentulous mandillae, in support of single or multiple-unit restorations and terminal or intermediate abutment support for fixed bridgework. They may be placed in immediate function if initial implant stability can be established.

    The Legacy Abutment System is intended for use with dental implants in the maxillary and/or mandbular arches to provide support for crowns, bridges, or overdentures for edentulous or partially edentulous patients.

    Device Description

    Not Found

    AI/ML Overview

    The provided text is a compilation of Indications for Use statements for various dental implant systems and components, all under the umbrella of "Implant Direct Dental Implant Systems Portfolio - MR Conditional." Each section describes the intended use for a specific product or family of products, often referencing previous 510(k) clearances.

    Crucially, this document does not contain any information about acceptance criteria or studies that prove the device meets these criteria. It is a regulatory filing for the Indications for Use for a medical device which has already been cleared by the FDA to be "substantially equivalent" to predicate devices.

    Therefore, I cannot fulfill the request to describe acceptance criteria and the study that proves the device meets the acceptance criteria based solely on the provided text. The document is for describing what the device is for, not how its performance was tested or validated.

    To provide the requested information, I would need a different type of document, such as a summary of safety and effectiveness, a clinical study report, or a validation plan for a specific performance characteristic.

    Ask a Question

    Ask a specific question about this device

    K Number
    K171922
    Date Cleared
    2017-09-28

    (93 days)

    Product Code
    Regulation Number
    872.3630
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Anatotemp Anatomic Dental Implant Healing Abutment is a pre-manufactured healing abutment intended for use with endosseous root-form dental implants to aid in prosthetic rehabilitation. The abutment is a temporary device that aids in creating an esthetic emergence through the gingiva during the healing period. The single use, sterilized device is used by dental professionals during the dental implant healing process and is removed prior to permanent prosthetic placement.

    Anatotemp Anatomic Dental Implant Healing Abutments are compatible with the following implant systems:

    Implant Brand and TypeImplant Platform Size
    Implant Direct Legacy3.5mmD, 4.5mmD, 5.7mmD
    Implant Direct ReActive3.5mmD, 4.3mmD, 5.0mmD
    Implant Direct RePlus3.5mmD, 4.3mmD, 5.0mmD
    Implant Direct RePlant3.5mmD, 4.3mmD, 5.0mmD, 6.0mmD
    Implant Direct SwishPlus4.8mmD, 6.5mmD
    Implant Direct InterActive3.0mmD, 3.4mmD
    Implant Direct SwishActive3.0mmD, 3.4mmD
    Blue Sky Bio QuattroRegular Platform (RP)
    Device Description

    The Anatotemp Anatomic Dental Implant Healing Abutment product line includes anatomically shaped temporary dental implant healing abutments that aid in creating an esthetic emergence through the gingiva during the healing period. Anatotemp Anatomic Dental Implant Healing Abutments are made of a polymethylmethacrylate biocompatible plastic and are held securely to an endosseous implant with a titanium abutment screw. Anatotemp Anatomic Dental Implant Healing Abutments are positioned well below the occlusal plane and are non-load bearing components that guide healing tissue.

    Anatotemp Anatomic Dental Implant Healing Abutments are designed not to be in occlusion or sustain occlusal forces. Anatotemp Anatomic Dental Implant Healing Abutments come in six shapes that mimic original tooth shape at the gingival level and also exhibit a mild, biconcave shape interproximally that aids in creating an esthetic emergence through the gingiva during the healing period. Anatotemp Anatomic Dental Implant Healing Abutments exhibit anti-rotational connections that are compatible with many dental implant connections. Anatotemp Anatomic Dental Implant Healing Abutments are provided sterile, are single use, and are recommended for temporary placement of no longer than 180 days. Anatotemp Anatomic Dental Implant Healing Abutments are removed after dental implant healing (approximately 90-180 days) and replaced by the permanent abutment and crown.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the "Anatotemp Anatomic Dental Implant Healing Abutment." This document focuses on demonstrating substantial equivalence to a predicate device, rather than proving the device meets acceptance criteria through a clinical study with a specific test set, ground truth, and expert adjudication as one would find for a novel AI/imaging device.

    Therefore, many of the requested criteria cannot be directly extracted from this document, as the regulatory pathway for this device (a dental implant healing abutment) does not involve the same type of performance evaluation as, for instance, an AI-powered diagnostic imaging system.

    This document primarily relies on non-clinical testing (biocompatibility, chemical characterization, packaging, sterilization, shelf-life, and reverse engineering analysis) and comparison to a predicate device to establish substantial equivalence. It explicitly states that "Formal clinical studies were not conducted to support the claim for substantial equivalence to the predicate device."

    Here's an attempt to address your points based on the provided text, highlighting where information is not applicable or not present for this type of device submission:


    Acceptance Criteria and Device Performance for the Anatotemp Anatomic Dental Implant Healing Abutment

    Since this is a 510(k) submission for a physical medical device (dental implant healing abutment) demonstrating substantial equivalence to a predicate, the "acceptance criteria" and "device performance" are typically related to material properties, biocompatibility, sterility, and functional equivalence, rather than diagnostic accuracy metrics as would be seen for an AI system. The study described is a series of non-clinical tests and a comparison.

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria are implicitly defined by the standards and characteristics required for demonstrating substantial equivalence to the predicate device, as well as the successful completion of the non-clinical tests. Performance is reported as meeting these standards.

    Acceptance Criterion (Implicit)Reported Device Performance
    Material Biocompatibility (Abutment - PMMA)Successful completion of ISO 10993-5 (Cytotoxicity), ISO 10993-10 (Maximization Sensitization, Intracutaneous Study), ISO 10993-11 (Systemic Toxicity), ISO 10993-3 (Bacterial Reverse Mutation), ISO 10993-6 (Implantation - 4 wk rabbit, 9 wk rabbit), and ISO 10993-10 (Intracutaneous Study w/ EO Cycle 20).
    Conclusion: "would not be expected to be toxic, carcinogenic, or cause adverse reactions when in contact with tissue/bone."
    Material Biocompatibility (Titanium Dental Screw)Successful completion of ISO 10993-5 (Cytotoxicity).
    Conclusion: "showed no evidence of causing cell lysis or toxicity."
    Chemical Characterization (Abutment Material)Performed according to ISO 10993-18 and USP Physiochemical Tests - Plastics . (Specific results not detailed beyond "performed.")
    Sterilization EfficacyValidated per EN ISO 11135:2014 and ISO 11135:2014 (overkill half-cycle approach).
    Demonstrated ability to be reliably sterilized to a sterility level of 10-6 using Cycle 20 (EXC-1).
    Packaging Integrity & Sterility MaintenanceValidated per BS EN ISO 11607-1:2009+A1:2014.
    Distribution simulation study met stated requirements. Accelerated aging (36 months) per ASTM F1980-07 (2011) met stated requirements (visual inspection, dye penetration, peel testing).
    Longevity/Temporary Use DurationTested to support a maximum temporary placement of 180 days (compared to predicate's 90 days). Implied success as it's presented as not affecting substantial equivalence.
    Compatibility with OEM Implant SystemsReverse engineering analysis conducted on OEM implant systems. Measurements and statistical analysis performed to identify tolerance limits.
    "Previously described engineering studies will be performed on an annual basis" to ensure ongoing compatibility.
    Substantial Equivalence to Predicate Device (Contour Healer)Demonstrated through comparison of intended use, technological characteristics, and performance data, addressing differences in material (PMMA vs. PEEK Classix) and maximum implantation time (180 vs. 90 days) with supporting non-clinical data.

    2. Sample Size Used for the Test Set and Data Provenance

    • Test Set Sample Size: For the non-clinical testing, specific sample sizes are not explicitly stated for each test (e.g., number of animals for biocompatibility, number of packages/devices for sterilization/packaging). The document mentions "sample of the OEM implants were measured" for reverse engineering. This is not a "test set" in the context of an AI study.
    • Data Provenance: Not applicable for this type of submission. The data is generated from internal company testing and contract lab testing, not patient data from a specific country or collected retrospectively/prospectively in a clinical setting.

    3. Number of Experts Used to Establish Ground Truth and Qualifications

    • Not applicable. This device does not use human "experts" to establish a ground truth for performance evaluation in the way an AI diagnostic imaging system would. The "ground truth" for the non-clinical tests is established by adherence to recognized international standards (ISO, ASTM, USP) and laboratory protocols.

    4. Adjudication Method for the Test Set

    • Not applicable. There is no "test set" in the context of human interpretation or diagnostic accuracy for this device.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done

    • No. The document explicitly states: "Formal clinical studies were not conducted to support the claim for substantial equivalence to the predicate device..." An MRMC study is a type of clinical study, typically for diagnostic devices or AI assistance in interpretation.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was Done

    • Not applicable. This is a physical medical device, not an algorithm.

    7. The Type of Ground Truth Used

    • The "ground truth" for this submission type is based on:
      • Regulatory Standards: Compliance with ISO, ASTM, and USP standards for biocompatibility, sterility, packaging, etc.
      • Engineering Specifications: Data derived from reverse engineering analysis of OEM implant systems to ensure compatibility.
      • Predicate Device Equivalence: The characteristics and performance of the legally marketed predicate device (Contour Healer).

    8. The Sample Size for the Training Set

    • Not applicable. This is not an AI/machine learning device. There is no "training set."

    9. How the Ground Truth for the Training Set was Established

    • Not applicable. There is no "training set."