Search Filters

Search Results

Found 2 results

510(k) Data Aggregation

    K Number
    K243410
    Device Name
    simpli-COLLECT STI Test
    Manufacturer
    Abbott Molecular
    Date Cleared
    2025-01-30

    (90 days)

    Product Code
    QYA, OYA
    Regulation Number
    866.3385
    Why did this record match?
    Product Code :

    QYA

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The simpli-COLLECT STI Test is a test system intended for in vitro detection and identification of Chlamydia trachomatis (CT), Neisseria gonorrhoeae (NG), Trichomonas vaginalis (TV), and Mycoplasma genitalium (MG) in home-collected specimens. The specimens are shipped to a clinical laboratory for testing using the Alinity m STI Assay with the automated Alinity m System for the direct, qualitative detection and differentiation of ribosomal RNA from CT, DNA from NG, ribosomal RNA from TV, and ribosomal RNA from MG, to aid in the diagnosis of disease(s) caused by infection from these organisms. The assay may be used to test the following self-collected specimens from symptomatic and asymptomatic individuals for the following analytes: - · CT: vaginal swabs, female urine and male urine . - NG: vaginal swabs, female urine, and male urine . - . · TV: vaginal swabs, female urine and male urine - . • MG: vaginal swabs and male urine The simpli-COLLECT STI Test contains all the necessary components for the selfcollection and transport of urine from male and female patients (simpli-COLLECT Urine Collection Kit) or vaginal swabs from female patients (simpli-COLLECT Swab Collection Kit) in their home, or in similar environments. The simpli-COLLECT Collection Kits may also be used to self-collect specimens in a clinic.
    Device Description
    The simpli-COLLECT STI Test is a test system intended for in vitro detection and identification of Chlamydia trachomatis (CT), Neisseria gonorrhoeae (NG), Trichomonas vaginalis (TV), and Mycoplasma genitalium (MG) in home-collected specimens (simpli-COLLECT Urine Collection Kit [09N93001] and the simpli-COLLECT Swab Collection Kit [09R02-001]). This test system uses the Alinity m STI Assay (cleared under K202977 and K222379) for real time RT-PCR to amplify and detect Chlamydia trachomatis (CT) ribosomal RNA sequences, Neisseria gonorrhoeae (NG) genomic DNA sequences, Trichomonas vaginalis (TV) ribosomal RNA sequences, Mycoplasma genitalium (MG) ribosomal RNA sequences, and human genomic DNA sequences that have been extracted from vaginal swab specimens or male and female urine specimens. The Alinity m STI assay requires two separate assay-specific kits as follows: - . Alinity m STI AMP Kit (09N17-095), which consists of multi-well amplification plates containing lyophilized, unit-dose RT-PCR amplification/detection reagents, and multi-well activator plates containing liquid, unit-dose activation reagents (MgC12. TMAC, and KC1). The intended storage condition for the Alinity m STI AMP Kit is 2°C to 8°C. - . Alinity m STI CTRL Kit (09N17-085), which consists of negative controls and positive controls, each supplied as liquid in single-use tubes. The intended storage condition for the Alinity m STI Control Kit is -15°C to -25°C. The steps of the Alinity m STI assay consist of sample preparation. RT-PCR assembly, amplification/detection, and result calculation and reporting. All stages of the Alinity m STI assay procedure are executed automatically by the Alinity m System. No intermediate processing or transfer steps are performed by the user. The Alinity m System is designed to be a random-access analyzer that can perform the Alinity m STI assay in parallel with other Alinity m assays on the same instrument. Nucleic acids from specimens are extracted automatically on-board the Alinity m System using the Alinity m Sample Prep Kit 1, Alinity m Lysis Solution, Alinity m Ethanol Solution or Alinity m Bottle for Ethanol Use filled with Ethanol supplied by customers, and Alinity m Diluent Solution. The Alinity m System employs magnetic microparticle technology to facilitate nucleic acid capture, wash, and elution. The resulting purified nucleic acids are then combined with the liquid unit dose activator reagent, lyophilized unit-dose Alinity m STI amplification reagents, and Alinity m Vapor Barrier Solution, and transferred by the instrument to an amplification/detection module for reverse transcription, PCR amplification, and real-time fluorescence detection. Assay controls are tested at or above an established minimum frequency to help ensure that instrument and reagent performance remain satisfactory. During each control event, a negative control and a positive control are processed through sample preparation and RT-PCR procedures that are identical to those used for specimens. Assay controls are used to demonstrate proper sample processing and assay validity. The CTRL kit configuration includes 12 vials at 0.47 mL of both the Alinity m STI Negative CTRL and Alinity m STI Positive CTRL. The Alinity m STI amplification reagents include primers and probes that amplify and detect the single copy human gene, ß-globin. Amplification and detection of the ß-globin gene demonstrates proper sample processing and adequate sample input. In addition, an exogenous internal control (containing an armored RNA sequence) is included in the lyophilized Alinity m STI amplification reagents and is used to confirm that no PCR inhibitors are present in the sample. The ß-globin control and internal control are both used to demonstrate assay validity. The AMP kit configuration includes 4 trays (96 tests per tray) of both an AMP TRAY 1 and ACT TRAY 2. The AMP Kit provides sufficient reagents for 384 tests. The simpli-COLLECT Urine Collection Kit is used to collect, stabilize, and transport male urine specimens for the detection of Chlamydia trachomatis, Neisseria gonorrhoeae. Trichomonas vaginalis, and Mycoplasma genitalium, and female urine specimens for the detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Trichomonas vaginalis. Each kit can be used to collect 1 urine specimen. The collected specimens are intended for testing with the Alinity m STI assay. The simpli-COLLECT Urine Collection Kit contains the following components: 1 Abbott Sample Collection pack, which contains 1 Alinity m Sample Tube with Liguid Buffer and 1 Transfer Pipette, 1 Tube and Bag Label Sheet, 1 Urine Cup/Urine Collection Cup, 1 simpli-COLLECT Urine Collection Kit Patient Instructions For Use, 1 Biohazard Bag with Absorbent Pad, 1 Tube and Cap Holder, and 1 simpli-COLLECT Urine Collection Kit Box. The simpli-COLLECT Swab Collection Kit is used to collect, stabilize, and transport vaginal swab specimens for the detection of Chlamydia trachomatis, Neisseria gonorrhoeae, Trichomonas vaginalis, and Mycoplasma genitalium. Each kit can be used to collect 1 vaginal swab specimen. The collected specimens are intended for testing with the Alinity m STI assay. The simpli-COLLECT Swab Collection Kit contains the following components: 1 Abbott Swab Collection pack, which contains 1 Alinity m Sample Tube with Liguid Buffer and 1 Specimen Collection Swab, 1 Tube and Bag Label Sheet, 1 Biohazard Bag with Absorbent Pad, 1 Tube and Cap Holder, 1 simpli-COLLECT Swab Collection Kit Patient Instructions For Use, and 1 simpli-COLLECT Swab Collection Kit Box.
    Ask a Question
    K Number
    DEN200070
    Device Name
    Simple 2 Test
    Manufacturer
    LetsGetChecked Inc. (formerly PrivaPath Diagnostics Inc.)
    Date Cleared
    2023-11-15

    (1094 days)

    Product Code
    QYA
    Regulation Number
    866.3385
    Why did this record match?
    Product Code :

    QYA

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The Simple 2 Test is intended for in vitro detection and identification of Chlamydia trachomatis (CT) and/or Neisseria gonorrhoeae (GC) in home-collected specimens which are shipped to a clinical laboratory for testing using the Aptima Combo 2 Assay on the Panther System. This product is available over-the-counter (OTC) to consumers 18 years of age and older. The Simple 2 Test contains all the necessary components to collect urine from male patients (Simple 2 Urine Home Collection Kit (Penile)) or vaginal swabs from female patients (Simple 2 Swab Home Collection Kit (Vaginal)) in their home, or in similar environments, without supervision from a healthcare provider. The Simple 2 Test Collection Kits may also be used to self-collect specimens in a clinic. The testing is performed, as determined to be appropriate, based on the results of LetsGetChecked Suitability Questionnaire. This test system is not a substitute for visits to a healthcare provider. The information provided by this product should not be used to start, stop, or change any course of treatment unless advised by your healthcare provider. Testing is limited to the manufacturer, Priva Path laboratories (d.b.a. LetsGetChecked. Inc.).
    Device Description
    The LetsGetChecked Simple 2 Test is composed of the Simple 2 Urine Home Collection Kit (Penile) and the Simple 2 Swab Home Collection Kit (Vaginal) and the samples are shipped to LetsGetChecked's Clinical Laboratory Improvement Amendments (CLIA)-certified laboratory for processing using the Aptima Combo 2 Assay on the Panther System. The Aptima Combo 2 Assay was previously cleared for the qualitative in vitro detection of Chlamydia trachomatis (CT) and/or Neisseria gonorrhoeae (GC) when used with male urine and self-collected vaginal swabs collected in clinical settings. The home collection kits are intended to be distributed for purchase online without the need for prescription from a physician or healthcare professional (over-the-counter use). After purchase, the user activates the kit on LetsGetChecked's website and is requested to fill out the Suitability Questionnaire to determine whether this test is appropriate for this individual. The user follows detailed directions for self-collecting a urogenital specimen (male urine or female vaginal swab, as applicable), packaging and shipping it to the LetsGetChecked CLIA certified laboratory for testing (PrivaPath lab). The test results are delivered to the individual via LetsGetChecked online portal. Positive and invalid/inconclusive results are followed up with a call from the LetsGetChecked Care Team. If the patient received a positive chlamydia result, treatment options are discussed. Patients receiving a positive gonorrhea test result, will be advised to contact their healthcare provider to receive appropriate treatment. The LetsGetChecked Care Team will also contact all patients who test negative for chlamydia and gonorrhea, but do report symptoms, or concerns, or where further investigation is indicated. These patients are internally flagged for follow-up.
    Ask a Question