510(k) Data Aggregation

    K Number
    K053497
    Device Name
    GUAVA EZCD4 SYSTEM
    Manufacturer
    GUAVA TECHNOLOGIES, INC.
    Date Cleared
    2006-04-14

    (120 days)

    Product Code
    GKZ
    Regulation Number
    864.5220
    Why did this record match?
    Applicant Name (Manufacturer) :

    GUAVA TECHNOLOGIES, INC.

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The EZCD4 Assay is intended to be performed on a Guava PCA System with CytoSoft 2.3 version software which includes three modules; EZCD4, Guava Check and Clean and Shutdown. The system is intended to identify and quantify the absolute counts of CD4 T-Lymphocytes in EDTA whole blood. The GuavaEZCD4 system is intended for the ongoing monitoring of patients with documented diagnosis of an immunodeficiency disease. The Guava EZCD4 system is intended for use only by trained laboratory professionals.
    Device Description
    The Guava EZCD4 System is an optimized cell analysis system consisting of the Guava PCA instrument, EZCD4 software for data acquisition and analysis and an EZCD4 Reagent Kit consisting of optimized reagents and protocols. The Guava EZCD4 Reagent Kit is a two-color direct immunofluorescence kit used for the enumeration of mature CD4 T lymphocytes in human blood. It consists of a monoclonal anti-human CD3 antibody conjugated to the tandem dye, phycoerythrin (PE)-Cy5 (PECy5) and a monoclonal anti-human CD4 antibody conjugated to PE. Guava 1X Lysing Solution and Guava Fixative are available in separate packaging and are added, after staining, to lyse erythrocytes and to preserve cells respectively. The Guava PCA instrument includes a laptop computer. The Guava PCA incorporates a new technology termed micro capillary cytometry. The device is a 3-parameter flow cytometer that utilizes a solid state 532 nm green laser, a fixed optical & fluidic system, a self-aligning flow cell and a micro capillary delivery system to perform cell analysis. The micro-syringe stepper pump allows the use of small sample volumes and volumetric measurements for the determination of absolute counts per microliter. The Guava PCA optic system detects forward scatter and two different wavelengths of fluorescence, 580/20 nm and 675/20 nm. It has a small foot print, 21.6 cm x 32 cm x 36.3 cm and is equipped with a network ready laptop computer with a 10GB hard drive and Windows 2000 operating system. The software is application specific with onscreen messaging enabling ease of use and facilitates short, effective training programs. Data is readily analyzed immediately after acquisition and is stored as electronic files on the hard drive.
    Ask a Question

    Page 1 of 1