LAF · Gas Chromatography, Methamphetamine

Clinical Toxicology · 21 CFR 862.3610 · Class 2

Overview

Product CodeLAF
Device NameGas Chromatography, Methamphetamine
Regulation21 CFR 862.3610
Device ClassClass 2
Review PanelClinical Toxicology
3rd-Party ReviewableYes

Identification

A methamphetamine test system is a device intended to measure methamphetamine, a central nervous system stimulating drug, in serum, plasma, and urine. Measurements obtained by this device are used in the diagnosis and treatment of methamphetamine use or overdose.

Classification Rationale

Class II (special controls). A methamphetamine test system is not exempt if it is intended for any use other than employment or insurance testing or is intended for Federal drug testing programs. The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 862.9, provided the test system is intended for employment and insurance testing and includes a statement in the labeling that the device is intended solely for use in employment and insurance testing, and does not include devices intended for Federal drug testing programs (e.g., programs run by the Substance Abuse and Mental Health Services Administration (SAMHSA), the Department of Transportation (DOT), and the U.S. military).

Special Controls

*Classification.* Class II (special controls). A methamphetamine test system is not exempt if it is intended for any use other than employment or insurance testing or is intended for Federal drug testing programs. The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 862.9, provided the test system is intended for employment and insurance testing and includes a statement in the labeling that the device is intended solely for use in employment and insurance testing, and does not include devices intended for Federal drug testing programs (*e.g.,* programs run by the Substance Abuse and Mental Health Services Administration (SAMHSA), the Department of Transportation (DOT), and the U.S. military).

Recent Cleared Devices (20 of 49)

Showing 20 most recent of 49 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K203647SEFRIA Methamphetamine Oral Fluid Enzyme ImmunoassayImmunalysis CorporationDec 22, 2021SESE
K210212Psychemedics Homogeneous Enzyme Immunoassay for Amphetamines in HairPsychemedics CorporationDec 15, 2021SESE
K201442Lin-Zhi International, Inc. (LZI) Methamphetamine Enzyme Immunoassay for Pictus AnalyzersDiatron GroupJul 31, 2020SESE
K170222Rapid Tox Cup IIAmerican Bio Medica Corp.Aug 15, 2017SESE
K153693Immunalysis Methamphetamine Urine Enzyme Immunoassay, Immunalysis Multi-Drug CalibratorsImmunalysis CorporationMar 18, 2016SESE
K142293Rapidfret Oral Fluid Assay for Methamphetamine, Rapidfret Oral Fluid Methamphetamine Calibrators, Rapidfret Oral Fluid Methamphetamine ControlsBiophor Diagnostics, Inc.Sep 18, 2015SESE
K150096Healgen MDMA (Ecstacy) Test (Strip, Cassette, Cup, Dip Card), Healgen Phencyclidine Test (Strip, Cassette, Cup, Dip Card)Healgen Scientific,, LLCMar 4, 2015SESE
K150162First Sign Drug of Abuse Dip Card Test, First Sign Drug of Abuse Cup TestW.H.P.M., Inc.Feb 26, 2015SESE
K133047RAPIDFRET ORAL FLUID ASSAY FOR MDMA, RAPIDFRET ORAL FLUID CALIBRATORS, RAPIDFRET ORAL FLUID CONTROLS, RAPIDEASE ORAL FLUBiophor Diagnostics, Inc.Dec 18, 2014SESE
K131652LZI ORAL FLUID METHAMPHETAMINE ENZYME IMMUNOASSAY, CALIBRATORS, CONTROLSLin-Zhi International, Inc.Mar 21, 2014SESE
K111927PSYCHEMEDICS METHAMPHETAMINE EIAPsychemedics Corp.May 1, 2012SESE
K113661LZI METHAMPHETAMINE ENZYME MMUNOASSAY, LZI METHAMPHETAMINE CALIBRATORS, LZI METHAMPHETAMINE CONTROLSLin-Zhi International, Inc.Jan 23, 2012SESE
K112236WONDFO METHYLENEDIOXYMETHAMPHETAMINE URINE TEST, WONDFO MORPHINE URINE TESTGuangzhou Wondfo Biotech Co., Ltd.Sep 19, 2011SESE
K101973OMEGA LABORATORIES HAIR DRUG SCREENING ASSAY FOR METHAMPHETAMINE AND 4-METHYLENEDIOXYMETHAMPHETAMINE (MDMA)Omega Laboratories, Inc.Aug 16, 2011SESE
K101753THERMO SCIENTIFIC CEDIA METHAMPHETAMINE OFT ASSAYMicrogenics Corp.Apr 8, 2011SESE
K093884ROCHE FLUDI METHAMPHETAMINERoche DiagnosticsFeb 25, 2011SESE
K080455RAPIDSENSE DRUGS OF ABUSE METHAMPHETAMINE (MET) 1000 DEVICE, MODEL 900-0050Quantrx Biomedical CorporationDec 31, 2008SESE
K080381QUEST DIAGNOSTICS METHAMPHETAMINE MICRO-PLATE EIAQuest Diagnostics, Inc.Jun 25, 2008SESE
K062242METHAMPHETAMINE ORAL FLUID HOMOGENEOUS ENZYME IMMUNOASSAY; CALIBRATORS AND CONTROLSLin-Zhi International, Inc.Sep 29, 2006SESE
K051577IMMUNALYSIS METHAMPHETAMINE ELISA FOR ORAL FLUIDSImmunalysis CorporationOct 4, 2005SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...