DSL ACTIVE NON-EXTRACTION IGF-I ELISA
Device Facts
| Record ID | K971353 |
|---|---|
| Device Name | DSL ACTIVE NON-EXTRACTION IGF-I ELISA |
| Applicant | Diagnostic Systems Laboratories, Inc. |
| Product Code | CFL · Clinical Chemistry |
| Decision Date | May 12, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 862.1370 |
| Device Class | Class 1 |
Indications for Use
The DSL IGF-I ELISA assay is intended for the quantitative determination of IGF-1 in human serum. The measurement of serum IGF-I is used as a diagnostic aid in the evaluation of growth-related disorders.
Device Story
DSL 10-2800 IGF-I ELISA kit; enzyme-linked immunosorbent assay (ELISA) for quantitative measurement of Insulin-like Growth Factor-I (IGF-I) in human serum. Principle: capture assay; mouse monoclonal antibody to IGF-I immobilized on microtitration wells; IGF-I in samples sandwiched between immobilized antibody and horseradish peroxidase-conjugated anti-IGF-I antibody. Used in clinical laboratory settings by trained personnel. Output: quantitative IGF-I concentration. Clinical utility: diagnostic aid for growth-related disorders.
Clinical Evidence
Bench testing only. Comparative study of 319 patient samples using DSL 10-2800 ELISA and DSL 2800 IRIMA. Linear regression analysis: Y = 0.60(X) + 0.73; correlation coefficient r = 0.82.
Technological Characteristics
Enzyme-linked immunosorbent assay (ELISA) format. Components: microtitration wells coated with mouse monoclonal anti-IGF-I antibody; horseradish peroxidase-conjugated anti-IGF-I antibody. Detection via enzymatic reaction.
Indications for Use
Indicated for quantitative determination of IGF-1 in human serum as a diagnostic aid in evaluating growth-related disorders.
Regulatory Classification
Identification
A human growth hormone test system is a device intended to measure the levels of human growth hormone in plasma. Human growth hormone measurements are used in the diagnosis and treatment of disorders involving the anterior lobe of the pituitary gland.
Predicate Devices
- DSL 2800 IGF-I IRIMA
Related Devices
- K961172 — DSL ACTIVE NON-EXTRACTION IGF-I IRMA · Diagnostic Systems Laboratories, Inc. · Apr 23, 1996
- K960551 — DSL ACTIVE HUMAN GROWTH HORMONE ELISA · Diagnostic Systems Laboratories, Inc. · Mar 6, 1996
- K970701 — DSL 1900 ACTIVE HUMAN GROWTH HORMONE IRMA (DSL 1900) · Diagnostic Systems Laboratories, Inc. · Apr 2, 1997
- K170938 — CalSet IGF-1 · Roche Diagnostics · Apr 26, 2017
- K962758 — DSL 9100 IGF-II IRMA · Diagnostic Systems Laboratories, Inc. · Aug 30, 1996