DSL ACTIVE NON-EXTRACTION IGF-I IRMA
Device Facts
| Record ID | K961172 |
|---|---|
| Device Name | DSL ACTIVE NON-EXTRACTION IGF-I IRMA |
| Applicant | Diagnostic Systems Laboratories, Inc. |
| Product Code | CFL · Clinical Chemistry |
| Decision Date | Apr 23, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 862.1370 |
| Device Class | Class 1 |
Indications for Use
The DSL IGF-I IRMA assay is intended for the quantitative determination of IGF-I in human serum or EDTA plasma. The measurement of serum/plasma IGF-I is used as a diagnostic aid in the evaluation of growth status disorders.
Device Story
DSL 2800 IGF-I IRMA kit; immunoradiometric capture assay. Input: human serum or EDTA plasma samples. Principle: IGF-I analyte captured between immobilized mouse monoclonal antibody on test tube surface and Iodine-125 labeled goat-anti-IGF-I polyclonal antibody. Output: quantitative IGF-I concentration. Used in clinical laboratory settings by trained technicians. Results assist clinicians in diagnosing and monitoring growth status disorders.
Clinical Evidence
Bench-only study comparing subject device to predicate (DSL 5600). Sample size n=146 patient samples covering low, intermediate, and high IGF-I levels. Linear regression analysis: Y = 1.19(X) - 22.07; correlation coefficient (r) = 0.98.
Technological Characteristics
Immunoradiometric assay (IRMA) format. Capture mechanism: mouse monoclonal antibody immobilized on test tube surface; detection via Iodine-125 labeled goat-anti-IGF-I polyclonal antibody. Analyte: Insulin-like Growth Factor-I.
Indications for Use
Indicated for quantitative measurement of IGF-I in human serum or EDTA plasma to aid in evaluating growth status disorders in patients.
Regulatory Classification
Identification
A human growth hormone test system is a device intended to measure the levels of human growth hormone in plasma. Human growth hormone measurements are used in the diagnosis and treatment of disorders involving the anterior lobe of the pituitary gland.
Predicate Devices
- DSL 5600 IGF-I IRMA
Related Devices
- K971353 — DSL ACTIVE NON-EXTRACTION IGF-I ELISA · Diagnostic Systems Laboratories, Inc. · May 12, 1997
- K970701 — DSL 1900 ACTIVE HUMAN GROWTH HORMONE IRMA (DSL 1900) · Diagnostic Systems Laboratories, Inc. · Apr 2, 1997
- K962758 — DSL 9100 IGF-II IRMA · Diagnostic Systems Laboratories, Inc. · Aug 30, 1996
- K960551 — DSL ACTIVE HUMAN GROWTH HORMONE ELISA · Diagnostic Systems Laboratories, Inc. · Mar 6, 1996
- K170938 — CalSet IGF-1 · Roche Diagnostics · Apr 26, 2017