K Number
K021423
Device Name
INSTANT-VIEW FECAL OCCULT BLOOD RAPID TEST
Date Cleared
2002-06-17

(45 days)

Product Code
Regulation Number
864.6550
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
This Fecal Occult Blood (FOB) Ravid Test is an immunochemical device intended for the qualitative detection of Fecal Occult Blood by laboratories or physicians offices. It is useful to determining gastrointestinal (GI) bleeding found in a number of gastrointestinal (GI) disorders, e.g., diverticulitis, colitis, polyps, and colorectal cancer. This test is recommended for use in 1) routine physical examinations. when hospital patients are first admitted, 2) hospital monitoring for bleeding in patients. 3) screening for colorectal cancer or gastrointestinal bleeding from any source.
Device Description
The Instant-View™ Fecal Occult Blood Rapid Test is an immunochemical device for the qualitative detection of Fecal Occult Blood.
More Information

Not Found

No
The device description and performance studies indicate a standard immunochemical test, with no mention of AI or ML.

No.
This device is an immunochemical device intended for the qualitative detection of Fecal Occult Blood as a diagnostic tool, not for therapeutic purposes.

Yes

The device is intended for the qualitative detection of Fecal Occult Blood to determine gastrointestinal (GI) bleeding and to screen for colorectal cancer or gastrointestinal bleeding, which are diagnostic purposes.

No

The device description clearly states it is an "immunochemical device" and the performance studies involve testing physical samples and observing results on the device itself, indicating it is a physical test kit, not software.

Yes, this device is an IVD (In Vitro Diagnostic).

Here's why:

  • Intended Use: The intended use explicitly states it's for the "qualitative detection of Fecal Occult Blood by laboratories or physicians offices." This indicates it's a test performed on a biological sample (feces) outside of the body to provide information about a medical condition (gastrointestinal bleeding).
  • Device Description: The description reinforces that it's an "immunochemical device for the qualitative detection of Fecal Occult Blood," further confirming its nature as a diagnostic test.
  • Performance Studies: The document details various performance studies (sensitivity, specificity, interference, reproducibility, repeatability) which are standard for evaluating the performance of IVD devices.
  • Predicate Device: The mention of a predicate device (Hemoccult® test) which is a known IVD, also supports the classification of this device as an IVD.

Therefore, based on the provided information, the Fecal Occult Blood (FOB) Rapid Test is clearly an In Vitro Diagnostic device.

N/A

Intended Use / Indications for Use

This Fecal Occult Blood (FOB) Rapid Test is an immunochemical device intended for the qualitative detection of Fecal Occult Blood by laboratories or physicians offices. It is useful to determining gastrointestinal (GI) bleeding found in a number of gastrointestinal (GI) disorders, e.g., diverticulitis, colitis, polyps, and colorectal cancer.

This test is recommended for use in 1) routine physical examinations, when hospital patients are first admitted, 2) hospital monitoring for bleeding in patients, 3) screening for colorectal cancer or gastrointestinal bleeding from any source.

Product codes (comma separated list FDA assigned to the subject device)

KHE

Device Description

The Instant-View™ Fecal Occult Blood Rapid Test is an immunochemical device for the qualitative detection of Fecal Occult Blood.

Mentions image processing

Not Found

Mentions AI, DNN, or ML

Not Found

Input Imaging Modality

Not Found

Anatomical Site

Gastrointestinal (GI)

Indicated Patient Age Range

Not Found

Intended User / Care Setting

laboratories or physicians offices

Description of the training set, sample size, data source, and annotation protocol

Not Found

Description of the test set, sample size, data source, and annotation protocol

Sensitivity Study:
Forty stool extraction samples were spiked with human hemoglobin (hHb) at five levels of concentrations: 0, 37.5, 50, 62.5, and 2000ng/ml. Each level contained 8 samples. The samples were blind labeled and tested with three lots of Instant-View™ Fecal Occult Blood Rapid Test. Results were compared with one lot of the predicate device, the Hemoccult® Test.

Specificity Study (Cross-Reactivity):
Hemoglobin (Hb) from beef, chicken, fish, horse, goat, pig, rabbit, and sheep were added to human feces. Tests were performed with and without diluted hHb at 50 ug hHb/g feces.

Specificity Study (Interference of dietary substances):
Aqueous extracts of raw broccoli, cantaloupe, cauliflower, horseradish, Parsnip, red radish and turnip were added to the test device. The test device was also tested with 20 mg/ml solution of horseradish peroxidases. Extracts were added with and without diluted hHb at 50 ug hHb/g feces. Dietary iron and Vitamin C supplement were added with and without diluted human Hb at 50 µg hHb/g feces.

Specificity Study (Interference by toilet water additives and contaminants):
Tested with toilet bowl deodorizers/fresheners or cleaners. Tested with contaminated toilet bowl with residual human blood at a concentration equal to or higher than 50ng/ml.

Reproducibility and Repeatability Studies:
One hundred (100) human hemoglobin free stool extraction specimens were collected in-house and divided into 5 groups, 20 in each. These 5 groups were spiked with human hemoglobin at five different concentrations: 0, 37.5ng hHb/ml (25% lower than cut off), 50ng hHb/ml (cut off level), 62.5ng hHb/ml (25% higher than cut off), and 2000ng hHb/ml (equal to 2000ug hHb/g feces). These specimens were tested at three Physician Office Laboratories (POL) and a Reference Laboratory. All specimens were blind labeled.

Specimen Collection and Handling Study:
Fresh human hemoglobin free stool extraction specimens, total 120, were collected in-house and divided into 5 groups, 72 in each. These 5 groups were spiked with human hemoglobin at five different concentrations: 0, 37.5ng hHb/ml (25% lower than cut off), 50ng hHb/ml (cut off level), 62.5ng hHb/ml (25% higher than cut off), and 2000ng hHb/ml (equal to 2000ug hHb/g feces). The specimens in each group were further divided into three subgroups (A, B, C), 8 specimens of each concentration.
Group A: stored at 95°F (35°C) and tested at 1, 2, 3, 4, 5, 6, 7, 8, 9, and 10 days post preparation.
Group B: stored at 39.2°F (4 °C) and tested at 1, 2, 3, 4, 5, 6, 7 and 8 months post preparation.
Group C: stored at -40°F (-20°C) and tested at 6, 12, 18, 20, 22, 24, 25, and 26 months post preparation.
Samples were blind labeled and tested with three lots of Instant-View ™ FOB Rapid Test. Every test result was read by two independent readers.

Summary of Performance Studies (study type, sample size, AUC, MRMC, standalone performance, key results)

Sensitivity and prozone effect study:
Study type: In-house sensitivity study.
Results: The Instant-View™ FOB Rapid Test is able to detect human Hemoglobin (hHb) at the level close to or higher than 50μg hHb/g feces (50ng/ml extraction buffer). No interference from prozone effect was observed up to 2000ng hHb/ml (equivalent to 2mg hHb/g feces). The device has a sensitivity of 50 ng/ml and showed 100% agreement with the predicate device.

Specificity study:
Study type: In vitro cross-reactivity and interference studies.
Results (Cross-reactivity): Instant-View™ FOB Rapid Test gave negative test results when tested with hemoglobin of other spices (beef, chicken, fish, horse, goat, pig, rabbit, and sheep) and positive in all cases when hHb was present. The Hemoccult® test consistently gave false-positive results with other animal hemoglobins.
Results (Dietary substances): Instant-View™ FOB Rapid Test gave negative results when tested with vegetable extracts (raw broccoli, cantaloupe, cauliflower, horseradish, Parsnip, red radish, turnip) and horseradish peroxidases, and positive results when hHb was present. No interference was observed with dietary iron and Vitamin C supplements. The Hemoccult® Test consistently gave false-positive results to all cases with or without human Hb.
Results (Toilet water additives/contaminants): No false positive test results were observed with toilet bowl deodorizers/fresheners or cleaners. Some decreased sensitivity over three-fold. Human blood left in the toilet bowl may induce false positive results if the concentration is equal to or higher than 50ng/ml.

Reproducibility and Repeatability Studies:
Study type: Multi-site reproducibility and repeatability study.
Sample size: 100 human hemoglobin free stool extraction specimens.
Results:
Results obtained from three POL sites agreed 97.7 % (average) with the expected results.
Results obtained from the Reference laboratory agreed 99% with the expected results.
Overall accuracy: 98%.

Specimen Collection and Handling Study:
Study type: Specimen stability study.
Sample size: 120 fresh human hemoglobin free stool extraction specimens.
Results: Specimens collected may be stored up to 8 days at 95°F (35°C); 6 months at 39.2°F (4 °C), and at least 2 years at -4°F (-20°C).

Key Metrics (Sensitivity, Specificity, PPV, NPV, etc.)

Sensitivity: 50 ng/ml.
Accuracy (Overall): 98%.

Predicate Device(s): If the device was cleared using the 510(k) pathway, identify the Predicate Device(s) K/DEN number used to claim substantial equivalence and list them here in a comma separated list exactly as they appear in the text. List the primary predicate first in the list.

Hemoccult® test by Beckman Coulter, Inc., 510K# K880499.

Reference Device(s): Identify the Reference Device(s) K/DEN number and list them here in a comma separated list exactly as they appear in the text.

Not Found

Predetermined Change Control Plan (PCCP) - All Relevant Information for the subject device only (e.g. presence / absence, what scope was granted / cleared under the PCCP, any restrictions, etc).

Not Found

§ 864.6550 Occult blood test.

(a)
Identification. An occult blood test is a device used to detect occult blood in urine or feces. (Occult blood is blood present in such small quantities that it can be detected only by chemical tests of suspected material, or by microscopic or spectroscopic examination.)(b)
Classification. Class II (special controls). A control intended for use with an occult blood test is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9.

0

Instant-View™ Fecal Occult Blood Rapid Test

Description of the device

I. Product Name: Instant-View™ Fecal Occult Blood Rapid Test

II. Manufacturer:

Alfa Scientific Designs, Inc. 12330 Stowe Drive Poway. CA 92064 (858) 513-3888 Telephone: Fax: (858) 513-8388 Email: info@alfascientific.com

III. Common Name of the Device: Fecal Occult Blood (FOB) Test

IV. Trade Name of the Device: Instant-View™ Fecal Occult Blood Rapid Test

V. Establishment Registration Number: 2060833.

VI. Classification of the Device:

The Test Device is classified as Class II (21 CFR 864.6550).

VII. Intended Use:

This Fecal Occult Blood (FOB) Ravid Test is an immunochemical device intended for the qualitative detection of Fecal Occult Blood by laboratories or physicians offices. It is useful to determining gastrointestinal (GI) bleeding found in a number of gastrointestinal (GI) disorders, e.g., diverticulitis, colitis, polyps, and colorectal cancer.

This test is recommended for use in 1) routine physical examinations. when hospital patients are first admitted, 2) hospital monitoring for bleeding in patients. 3) screening for colorectal cancer or gastrointestinal bleeding from any source.

VIII. Predicate Product:

Hemoccult® test by Beckman Coulter, Inc., 510K# K880499.

IX. Performance Summary:

The Instant-View™ FOB Rapid Test is more accurate than the predicate device Hemoccult®. The performance of Instant-View™ FOB Rapid Test was verified by sensitivity, specificity, cross reactivity, interference, reproducibility and accuracy studies. Please refer the attached "Summary".

2

1

Device specifications

I. BACKGROUND

The American Cancer Society and National Cancer Institute guidelines for early detection of colorectal cancer recommend an occult blood stool test annually every 3-5 years after age 50 years. There are three types of tests for FOB testing are commercially available: 1) Guaiac Dye: 2) Immunochemical: and 3) Hemoporphyrin. The Guaiac test is widely available, but lack of high accuracy. The Hemoporphyin test is not affected by dietary peroxidases, but false-positive results can occur in patients with upper gastrointestinal bleeding disorders. This Immunochemical FOB test has great advantage than the Guaiac and Hemoporphyrin method. It is highly accurate, and the results are not interfered by dietary peroxidases, animal blood and ascorbic acid.

II. PERFORMANCE CHARACTERISTICS

1. Sensitivity and prozone effect study

The Instant-View™ FOB Rapid Test is able to detect the human Hemoglobin (hHb) at the level close to or higher than 50μg hHb/g feces (50ng/ml extraction buffer) and no interference from prozone effect was observed when the human hHb level reached up to 2000ng hHb/ml, which is equivalent to 2mg hHb/g feces.

A sensitivity study was conducted in-house to evaluate the minimum concentration of the human hemoglobin that has a high probability of being detected with this devise.

Forty stool extraction samples were spiked with human hemoglobin at five levels of concentrations, 0. 37.5, 50. 62.5, and 2000ng/ml, in an evenly distributed number. 8 of each level. The samples were blind labeled and tested with three lots of Instant-View™Fecal Occult Blood Rapid Test. Results were compared with one lot of predicate device, the Hemoccult® Test.

Results indicated that the Instant-View™ Fecal Occult Blood Rapid Test has a sensitivity of 50 ng/ml. and 100% agreed with predicate device.

2. Specificity study

Cross reactivity

The Instant-View™ FOB Rapid Test was examined in vitro by adding hemoglobin (Hb) of beef, chicken, fish, horse, goat, pig, rabbit, and sheep to the human feces and applied to the test to determine the cross-reactivity of the test with the hemoglobin from other spices. The samples were added with and without diluted hHb at 50 ug hHb/g feces. Instant-View™ FOB Rapid Test gave negative test results when tested with the Hb of other spices and positive in all cases when hHb was present. Whereas the Hemoccult® test consistently gave false-positive results when tested with all hemoglobin of other spices.

2

Abbreviated 510(k)

Interference of dietary substances .

Instant-View™ FOB Rapid Test does not require the patient to follow any special dietary restrictions. Aqueous extracts of raw broccoli, cantaloupe, cauliflower, horseradish, Parsnip, red radish and turnin were added to the Test device to determine if vegetable extracts cross react with the test. Test device was also tested with 20 mg/ml solution of horseradish peroxidases. The extracts were added with and without diluted hHb at 50 ug hHb/g feces (50ng/ml extraction buffer). Instant-View™ FOB Rapid Test gave negative results when tested with all of the extracts, and positive results when hHb was present. The Hemoccult® Test, a Guaiac FOB Test, consistently gave false-positive results to all the cases with or without human Hb. A dietary iron and Vitamin C supplement were added with and without diluted human Hb at 50 µg hHb/g feces (50ng/ml extraction buffer) to the test device. No interference was observed with the performance of the Instant-View™ FOB Rapist test.

Interference bv toilet water .

Additives:

No false positive test results were observed with toilet bowl deodorizers/fresheners or cleaners The effects of the toilet bowl deodorizers/fresheners or cleaners on the sensitivity of the test studied. are varying. Some decreased the sensitivity of the test by over three-fold, while others have no effect. Based on the results of these studies it is concluded that toilet bowl deodorizers/fresheners should be removed from the toilet bowl prior to collecting samples for the proposed test.

Contaminants:

Study on the contaminated toilet bowl with residual human blood indicated that the human blood left in the toilet bowl may induce false positive results, if the concentration of human blood is equal to or higher than 50ng/ml. Therefore, instructions were given that flush the toilet before use.

The specimen is suggested to be collected from the toilet paper or caught in a clean cup to avoid contacting toilet water.

3. Reproducibility and repeatability studies

One hundred (100) human hemoglobin free stool extraction specimens collected in house and divided into 5 groups in an evenly distributed number, 20 in each. The 5 groups of extraction samples were spiked with human hemoglobin for five different concentrations, respectively, 0, 37.5ng hHb/ml (25% lower than cut off), 50ng hHb/ml (cut off level), 62.5ng hHb/ml (25% higher than cut off), and 2000ng hHb/ml (equal to 2000ug hHb/g feces). Those specimens were tested with Instant-View™ Fecal Occult Blood Test at three (3) Physician Office Laboratories (POL) and a Reference Laboratory. All specimens were blind labeled.

The results obtained from three POL sites by persons with diverse education background and work experiences agreed 97.7 % (average) with the expected results. The results obtained from the Reference laboratory agreed 99% with the expected results. Overall, the accuracy of the Instant-View™ Fecal Occult Blood Rapid Test is 98%.

Specimen Collection and Handling 4.

Fresh human hemoglobin free stool extraction specimens, total 120 specimens, were collected in house and divided into 5 groups in an evenly distributed number, 72 in each group. Those 5 groups of

3

extraction samples were spiked with human hemoglobin for five different concentrations. respectively, 0, 37.5ng hHb/ml (25% lower than cut off), 50ng hHb/ml (cut off level), 62.5ng hHb/ml (25% higher than cut off), and 2000ng hHb/ml (equal to 2000ug hHb/g feces).

The specimens in each group were further divided into three groups, A, B, and C, 8 specimens of each concentration in each group.

Specimens of Group A were stored at temperature 95°F (35°C) and tested at 1, 2, 3, 4, 5, 6, 7, 8, 9, and 10 days post preparation. Specimens of Group B were stored at 39.2°F (4 °C) and tested at 1, 2, 3, 4. 5. 6. 7 and 8 months post preparation. Specimens of Group C were stored at -40F (-20°C) and tested at 6, 12, 18, 20, 22, 24, 25, and 26 months post preparation. The samples were blind labeled and tested with three lots of Instant-View ™ FOB Rapid Test. Every test result was read by two independent readers.

Results observed indicated that specimens collected may be stored up to 8 days at temperature 95°F (35°C); 6months at 39.2°F (4 °C), and at least 2 years at -4°F (-20°C).

4

Image /page/4/Picture/1 description: The image is a black and white logo for the U.S. Department of Health & Human Services. The logo features a stylized depiction of three human profiles facing to the right. The profiles are arranged in a way that they appear to be stacked on top of each other. The logo is encircled by the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA".

Food and Drug Administration 2098 Gaither Road Rockville MD 20850

JUN 1 7 2002

Naishu Wang, M.D., Ph.D. President Alpha Scientific Designs, Inc. 12330 Stowe Drive Poway, CA 92064

Re: K021423

Trade/Device Name: Instant-View™ Fecal Occult Blood Rapid Test Regulation Number: 21 CFR 864.6550 Regulation Name: Occult Blood Test Regulatory Class: Class II Product Code: KHE Dated: April 30, 2002 Received: May 3, 2002

Dear Dr. Wang:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations. Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807): labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

5

Page 2 -

This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and 1 additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4588. Additionally, for questions on the promotion and advertising of your device. please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsma/dsmamain.html".

Sincerely yours,

Steven Sutman

Steven I. Gutman, M.D., M.B.A. Director Division of Clinical Laboratory Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

6

510 (K) NUMBER (IF KNOWN) : KO214 23

DEVICE NAME : Instant-View™ Fecal Occult Blood Rapid Test

INDICATIONS FOR USE:

This Fecal Occult Blood (FOB) Rapid Test is an immunochemical device intended for the qualitative detection of Fecal Occult Blood by laboratories or physicians offices. It is useful to determining gastrointestinal (GI) bleeding found in a number of gastrointestinal (GI) disorders, e.g., diverticulitis, colitis, polyps, and colorectal cancer.

This test is recommended for use in 1) routine physical examinations, when hospital patients are first admitted, 2) hospital monitoring for bleeding in patients, 3) screening for colorectal cancer or gastrointestinal bleeding from any source.

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED . )

Concurrence of CDRH, Office of Device Evaluation (ODE)

Prescription Use (Per 21 CFR 801.109)

OR

Over-The-Counter Use (Optional Format 1-2-96)

Josephine Bautista

(Division Sign-Off) Division of Clinical Laborator 510(k) Number -