QuickRad is a web-based PACS intended for use in radiology centers, diagnostic labs, and hospitals. It is designed to receive, store, transmit, process, and display medical images and associated data from various DICOM-compliant sources, including CT scanners, MRI systems, ultrasound machines, and X-ray devices. The system enhances communication and accessibility by allowing distributed access to images and data across computer networks. QuickRad also offers optional integration with FDA-cleared third-party Al models, enabling the visualization of Al-generated outputs. The system displays these outputs "as-is," with the safety and effectiveness of the Al models being covered under the original third-party manufacturer's regulatory clearance.Mammographic images may only be interpreted using a monitor that meets the technical specifications identified by the FDA. The system is designed for utilization by proficient and certified medical practitioners, including physicians, radiologists, and medical technicians.
QuickRad is a web-based PACS designed to optimize radiology workflows and enhance clinical efficiency. It allows seamless receipt, management, and processing of DICOM images from various modalities, including CT, MRI, ultrasound, X-ray, and more.
Key Features and Functions:
- Comprehensive Radiology Management: QuickRad provides end-to-end functionality for the storage, transmission, processing, and visualization of medical images, ensuring seamless collaboration across healthcare networks.
- Zero Footprint Viewer (ZFP): QuickRad's ZFP viewer offers cross-platform accessibility without the need for additional native software installation. It is compatible with macOS, Windows, Ubuntu and Chrome, Edge, Firefox browsers.
- . Enhanced Viewer Options: QuickRad ensures that all scans are displayed with true-to-source fidelity, offering optional FDA-cleared viewer integrations that enhance diagnostic accuracy.
- . Advanced 3D Viewer: QuickRad's 3D viewer empowers radiologists with cutting-edge image analysis tools, including:
- o Smooth stack scrolling, zooming, panning, and reset options.
- O Measurement tools for length, angles, and annotations.
- Advanced visualization techniques such as Multiplanar Reconstruction (MPR) and Maximum Intensity O Projection (MIP).
- O PET scan mode with customizable contrast settings, annotation capabilities, and snapshot tools for enhanced diagnostic insights.
- . Smart Reporting Editor: QuickRad includes a modality-specific report editor that simplifies report creation. Pre-built templates for various imaging studies ensure consistent report generation with voiceenabled editing features.
- . AI Integration: QuickRad offers optional integration with FDA-cleared third-party AI models, allowing radiologists to review AI-generated results directly within the platform. The AI output is displayed alongside original images for confirmation by qualified medical professionals.
- DICOM Compliance: Fully compliant with DICOM standards, QuickRad guarantees secure and interoperable ● image and data exchange across systems, ensuring compatibility with a wide range of imaging devices.
- . Secure Data Transmission: It adheres to strict security protocols, utilizing HTTPS, AES 256 encryption, and multi-factor authentication (MFA) for secure access.
Here's a breakdown of the acceptance criteria and the study proving the device meets them, based on the provided text:
Device Name: QuickRad
Regulation Number: 21 CFR 892.2050 (Medical Image Management And Processing System)
Product Code: LLZ
QuickRad is a web-based PACS designed to receive, store, transmit, process, and display medical images and associated data from DICOM-compliant sources. It also offers optional integration with FDA-cleared third-party AI models for visualization of AI-generated outputs.
1. Table of Acceptance Criteria and Reported Device Performance
The non-clinical performance data section outlines the studies performed and their objectives, which serve as the acceptance criteria. The reported device performance is consistently stated as meeting these criteria.
| Acceptance Criteria / Study Objective | Reported Device Performance |
|---|---|
| Risk Management & Cybersecurity: | |
| - Device Hazard Analysis as per ISO 14971:2019 | Hazard analysis and mitigation strategies were validated, confirming QuickRad's compliance with ISO 14971:2019. |
| - Vulnerability Assessment & Penetration Testing (VAPT) based on OWASP Top 10 | Periodic VAPT by third-party consultants verified the adequacy of QuickRad's security controls, effectively mitigating potential cybersecurity risks. |
| Usability Testing: | |
| - Formative and Summative Usability Testing per IEC 62366-1:2015 | Usability testing, conducted in compliance with IEC 62366-1:2015, included both formative and summative evaluations, confirming QuickRad meets its intended use. |
| Software Verification & Validation: | |
| - Unit Testing based on Software Requirements Specifications (SRS) | Core functional components were independently tested, ensuring QuickRad's units work as intended, with code correctness validated. |
| - Integration Testing for interaction between software components | Seamless interaction between software components and external systems was confirmed. Seamless end functionality across its software components, including APIs, OTS/SOUP components detailed in the SBOM, independent libraries, and DICOM interfaces, was validated. |
| - System Testing covering end-to-end functionality | End-to-end functionality across all features was validated. System testing encompassed core functionalities such as user management, DICOM viewer operations, search capabilities, radiologist assignment workflows, report management, audit log tracking, error handling, and hospital management, ensuring robust performance and compliance with the system's defined specifications. |
| - Validation based on User Requirements Specifications (URS) | User Acceptance Testing verified QuickRad meets its intended use, ensuring adherence to the user requirement specifications documents through end-user validation. The test cases were addressed fully passed the acceptance criteria. |
| Measurement Study: | |
| - Establishing equivalence with FDA-cleared viewer (Angle Measurement) | Statistical analyses, including equivalence testing and T-tests, demonstrated that QuickRad's angle measurement tool is substantially equivalent to FlexView Diagnostic and produced clinically reliable angle assessments. |
| - Establishing equivalence with FDA-cleared viewer (Length, Rectangle, Ellipse ROI, Probe, Reference Line Measurements) | This comprehensive evaluation, encompassing diverse imaging modalities, confirmed that QuickRad delivers performance equivalent to the FDA-cleared FlexView Diagnostic DICOM Viewer (K233226), ensuring consistent, reliable, and clinically accurate measurements across the spectrum of diagnostic imaging. |
| 3rd Party AI Model Integration Interface Testing: | |
| - Confirm integrity of source DICOM file and AI model output during integration | The integration interface between QuickRad and 3rd party AI models were tested to confirm that the integrity of the source DICOM file and output from AI models is unaltered and hence, does not get impacted when the source file is sent to the AI model for findings and the AI model sends the output to QuickRad through the interface. |
2. Sample size used for the test set and the data provenance
- Angle Measurement Study: 12 X-ray images (AP Pelvic, AP Knee, Lateral Ankle).
- Data Provenance: Not explicitly stated (e.g., country of origin, retrospective/prospective). However, the context of a 510(k) submission for a PACS system suggests general medical imaging data.
- Other Measurement Studies (Length, Rectangle, Ellipse ROI, Probe, Reference Line): CT abdomen images for length, rectangle, ellipse ROI, and probe measurements; MR spine and brain images for reference line accuracy.
- Data Provenance: Not explicitly stated.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts
- Angle Measurement Study: "two experienced radiologists."
- Qualifications: "experienced radiologists" (further details like years of experience or board certification are not provided).
For other testing types (software V&V, cybersecurity, usability, AI integration), the concept of "ground truth established by experts" in the same way as for clinical performance is not directly applicable. These studies validate the software's functionality, security, and usability against predefined requirements and standards.
4. Adjudication method (e.g., 2+1, 3+1, none) for the test set
- Angle Measurement Study: "evaluated independently by two experienced radiologists." This suggests a comparison of their independent measurements against the device's measurements and the benchmark device. An explicit "adjudication" method (like a third reader resolving discrepancies) is not mentioned.
5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
- No, an MRMC comparative effectiveness study was not done for QuickRad itself for human reader improvement with AI assistance.
- QuickRad offers "optional integration with FDA-cleared third-party AI models," and explicitly states: "The solution only supports the visualization of outputs of 3rd party AI models 'as-is'. The safety and effectiveness of the 3rd party model are covered under the original 3rd party manufacturer's regulatory clearance."
- This means QuickRad does not claim to enhance human reader performance with its integrated AI. It merely displays the output of other cleared AI models. The effectiveness and safety of those AI models, including any human-AI collaboration benefits, would have been established in the separate regulatory clearances for those specific AI models (e.g., qXR, qCT LN Quant, qER, which are identified by their K-numbers).
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
- No, a standalone algorithm-only performance study was not done for QuickRad itself.
- QuickRad is a PACS/viewer, not a diagnostic AI algorithm. Its purpose is to manage and display images, and optionally display the output of other (standalone) FDA-cleared AI algorithms.
7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)
- For the measurement studies (angle, length, etc.): The ground truth was implicitly established by the measurements taken by the "two experienced radiologists" using a comparison against the FDA-cleared FlexView Diagnostic DICOM Viewer (K233226). This indicates a comparison to a cleared predicate device's performance as the benchmark/ground truth. It's not explicitly stated if a consensus was formed between the two radiologists or if their independent measurements were directly compared.
8. The sample size for the training set
- Not applicable. QuickRad is a PACS/viewer and not an AI algorithm itself. It does not have a "training set" in the machine learning sense. The individual third-party AI models that QuickRad integrates would have had their own training sets, but those are external to this submission.
9. How the ground truth for the training set was established
- Not applicable. (See point 8).
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows the logo of the U.S. Food and Drug Administration (FDA). The logo consists of two parts: the Department of Health & Human Services logo on the left and the FDA logo on the right. The FDA logo is in blue and includes the letters "FDA" in a square and the words "U.S. FOOD & DRUG ADMINISTRATION".
Aikenist Technologies Pvt Ltd % David Dills Regulatory Consultant David Dills 5450 Ariva Way #302 Lakeland, Florida 33812
February 21, 2025
Re: K242838
Trade/Device Name: QuickRad Regulation Number: 21 CFR 892.2050 Regulation Name: Medical Image Management And Processing System Regulatory Class: Class II Product Code: LLZ Dated: September 19, 2024 Received: January 23, 2025
Dear David Dills:
We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{1}------------------------------------------------
Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device" (https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download).
Your device is also subject to, among other requirements, the Quality System (QS) regulation (21 CFR Part 820), which includes, but is not limited to, 21 CFR 820.30, Design controls; 21 CFR 820.90, Nonconforming product; and 21 CFR 820.100, Corrective and preventive action. Please note that regardless of whether a change requires premarket review. the OS regulation requires device manufacturers to review and approve changes to device design and production (21 CFR 820.30 and 21 CFR 820.70) and document changes and approvals in the device master record (21 CFR 820.181).
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050.
All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Re"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advicecomprehensive-regulatory-assistance/unique-device-identification-system-udi-system.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems.
For comprehensive regulatory information about mediation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See
{2}------------------------------------------------
the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely,
Jessica Lamb
Jessica Lamb Assistant Director Imaging Software Team DHT8B: Division of Radiologic Imaging Devices and Electronic Products OHT8: Office of Radiological Health Office of Product Evaluation and Quality Center for Devices and Radiological Health
Enclosure
{3}------------------------------------------------
Indications for Use
Form Approved: OMB No. 0910-0120 Expiration Date: 07/31/2026 See PRA Statement below.
Submission Number (if known)
Device Name
QuickRad
Indications for Use (Describe)
QuickRad is a web-based PACS intended for use in radiology centers, diagnostic labs, and hospitals. It is designed to receive, store, transmit, process, and display medical images and associated data from various DICOM-compliant sources, including CT scanners, MRI systems, ultrasound machines, and X-ray devices. The system enhances communication and accessibility by allowing distributed access to images and data across computer networks. QuickRad also offers optional integration with FDA-cleared third-party Al models, enabling the visualization of Al-generated outputs. The system displays these outputs "as-is," with the safety and effectiveness of the Al models being covered under the original third-party manufacturer's regulatory clearance.Mammographic images may only be interpreted using a monitor that meets the technical specifications identified by the FDA. The system is designed for utilization by proficient and certified medical practitioners, including physicians, radiologists, and medical technicians.
Type of Use (Select one or both, as applicable)
Prescription Use (Part 21 CFR 801 Subpart D)
Over-The-Counter Use (21 CFR 801 Subpart C)
CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{4}------------------------------------------------
Image /page/4/Picture/1 description: The image shows the logo for Alkenist. The logo consists of the letters "AI" inside of a circle that is partially colored in yellow and blue. To the right of the circle is the word "Alkenist" in a sans-serif font.
510(k) Summary
[AS REQUIRED BY 21CFR807.92]
I. APPLICANT INFORMATION
| Submitter's Name | Aikenist Technologies Pvt. Ltd. | |
|---|---|---|
| Submitter's Address | 007, Pushpanjali, 1st Cross, 1st Main Road, Chamarajpet,Bangalore 560018, India | |
| Name of Contact Person | Ashwin Amarapuram Chandramouly | |
| Designation | Director and CEO | |
| Contact Number | +91 9845320314 | |
| Contact E-mail | ashwin@aikenist.com | |
| Date of Summary Prepared | 22 Jan 2025 |
II. DEVICE DETAILS
| Device Trade Name | QuickRad |
|---|---|
| Regulation Name/ Device Common Name | Medical image management and processing system |
| Regulation Number | 21 CFR 892.2050 |
| Device Class | Class 2 |
| Product Code | LLZ |
III. PREDICATE DEVICE DETAILS
| Device Trade Name | Augmento |
|---|---|
| Device Manufacturer Name | DEEPTEK MEDICAL IMAGING PRIVATE LIMITED |
| 510(k) Number | K222781 |
| Regulation Number | 21 CFR 892.2050 |
| Device Class | Class 2 |
| Product Code | LLZ |
Image /page/4/Picture/10 description: The image shows a black silhouette of a factory. The factory has three triangular peaks of the same height. To the right of the peaks is a tall rectangular chimney.
{5}------------------------------------------------
IV. DEVICE DESCRIPTION
QuickRad is a web-based PACS designed to optimize radiology workflows and enhance clinical efficiency. It allows seamless receipt, management, and processing of DICOM images from various modalities, including CT, MRI, ultrasound, X-ray, and more.
Key Features and Functions:
- Comprehensive Radiology Management: QuickRad provides end-to-end functionality for the storage, transmission, processing, and visualization of medical images, ensuring seamless collaboration across healthcare networks.
- Zero Footprint Viewer (ZFP): QuickRad's ZFP viewer offers cross-platform accessibility without the need for additional native software installation. It is compatible with macOS, Windows, Ubuntu and Chrome, Edge, Firefox browsers.
- . Enhanced Viewer Options: QuickRad ensures that all scans are displayed with true-to-source fidelity, offering optional FDA-cleared viewer integrations that enhance diagnostic accuracy.
- . Advanced 3D Viewer: QuickRad's 3D viewer empowers radiologists with cutting-edge image analysis tools, including:
- o Smooth stack scrolling, zooming, panning, and reset options.
- O Measurement tools for length, angles, and annotations.
- Advanced visualization techniques such as Multiplanar Reconstruction (MPR) and Maximum Intensity O Projection (MIP).
- O PET scan mode with customizable contrast settings, annotation capabilities, and snapshot tools for enhanced diagnostic insights.
- . Smart Reporting Editor: QuickRad includes a modality-specific report editor that simplifies report creation. Pre-built templates for various imaging studies ensure consistent report generation with voiceenabled editing features.
- . AI Integration: QuickRad offers optional integration with FDA-cleared third-party AI models, allowing radiologists to review AI-generated results directly within the platform. The AI output is displayed alongside original images for confirmation by qualified medical professionals.
- DICOM Compliance: Fully compliant with DICOM standards, QuickRad guarantees secure and interoperable ● image and data exchange across systems, ensuring compatibility with a wide range of imaging devices.
- . Secure Data Transmission: It adheres to strict security protocols, utilizing HTTPS, AES 256 encryption, and multi-factor authentication (MFA) for secure access.
V. INDICATIONS FOR USE
QuickRad is an advanced PACS solution, available for on-premise or cloud hosting. It receives medical images and data from various DICOM-compliant origins, such as CT, MR scanners, ultrasound systems, and X-ray machines. These images and data undergo storage, transmission, processing, and display within the system, fostering smooth communication and accessibility across distributed locations on computer networks. It provides optional integration with FDA-cleared 3rd party AI models. The solution only supports the visualization of outputs of 3rd party AI models "as-is". The safety and effectiveness of the 3rd party model are covered under the original 3rd party manufacturer's regulatory clearance. Mammographic images may only be interpreted using a monitor that meets the technical specifications identified by the FDA. The system is designed for utilization by proficient and certified medical practitioners, including physicians, radiologists, and medical technicians.
{6}------------------------------------------------
VI.COMPARISON OF TECHNOLOGICAL CHARACTERISTICS WITH THE PREDICATEDEVICE
Table 1. Summary of Technological Characteristics Comparison of DeepTek and QuickRad.
| SI.No | Features | Predicate Device-Augmento | Proposed Device- QuickRad | Remarks |
|---|---|---|---|---|
| General information | ||||
| 1. | 510(k) Number | K222781 | K242838 | - |
| 2. | Manufacturer | DeepTek Medical ImagingPrivate Limited | Aikenist TechnologiesPrivate Limited | - |
| 5. | Classification | Class II | Class II | Same |
| 6. | Regulation number | 21 CFR 892.2050 | 21 CFR 892.2050 | Same |
| 7. | Product Code | LLZ | LLZ | Same |
| 8. | Indications ForUse | Augmento is a web-based PACSand radiology workflowmanagement solution.It accepts digital images and datafrom various DICOM-compliantsources (i.e. CT scanners, MRscanners, ultrasound systems, RFUnits, PET Units, computed &digital radiographic devices,secondary capture devices,imaging gateways, and otherimaging sources). Images and datacan be stored, communicated,processed, and displayed withinthe system and/or across computernetworks at distributed locations.Only preprocessed DICOM "forpresentation" images can beinterpreted for primary imagediagnosis in mammography. Lossycompressed images and digitizedfilm screens of mammographicimages must not be reviewed forprimary image interpretations.Mammographic images may onlybe interpreted using a monitor thatmeets the technical specificationsidentified by the FDA. This systemis meant to be used by trained andqualified medical professionals | QuickRad is an advanced PACSsolution, available for on-premiseor cloud hosting. It receivesmedical images and data fromvarious DICOM-compliantorigins, such as CT, MR scanners,ultrasound systems, and X-raymachines. These images and dataundergo storage, transmission,processing, and display within thesystem, fostering smoothcommunication and accessibilityacross distributed locations oncomputer networks. It providesoptional integration with FDA-cleared 3rd party AI models. Thesolution only supports thevisualization of outputs of 3rdparty Al models "as-is". Thesafety and effectiveness of the 3rdparty model are covered under theoriginal 3rd party manufacturer'sregulatory clearance.Mammographic images may onlybe interpreted using a monitor thatmeets the technical specificationsidentified by the FDA.The system is designed forutilization by proficient and | Same |
| physicians, radiologists, nurses, and medical technicians. | certified medical practitioners, including physicians, radiologists, and medical technicians. | |||
| 9. | Prescription or OTC | Prescription | Same | |
| Specifications | ||||
| 10. | Modalities | Various image sources | Same | |
| 11. | Web browser software | Google Chrome, Mozilla, and Edge | Same | |
| 12. | Resolution | 32-bit Color Display & 1920x1080 | Same | |
| 13. | Image Storage | Yes | Same | |
| 14. | Software environment | OS: Windows 10 | Same | |
| Functions | ||||
| 15. | Main Functions | Log In Worklist - Search Filter Worklist - Open image Work list- study List Worklist - Report Worklist - Series Viewer - View exam Viewer - Control View window Viewer - view mode (real resolution) Viewer – View mode (Highlight) Viewer - Stacking Viewer – Changing the layout Viewer – Comparative study Viewer – Preset filter Viewer - Zoom Viewer – Panning Viewer - Invert Image Viewer – Viewing mode (Normal/ Image/ Stack/ Custom/ Annotation) Viewer - Comparative study Viewer - Rotation MIP/MPR Reconstruction Viewer – Reference line | Log In Worklist - Search Filter Worklist - Open image Work list- study List Worklist - Report Worklist - Series Viewer - View exam Viewer - Thumbnail view of the series Viewer-Changing the layout Viewer-Comparative study Viewer - Preset filter Viewer - Zoom Viewer - Panning Viewer - Invert Image Viewer – Viewing mode (Normal/Stack/ Custom/ Annotation/ synchronized screening) Viewer – Comparative study Viewer - Rotation Viewer- MIP/MPR Reconstruction Viewer – Reference line Viewer-Measurement- rectangular, ellipse, angle/cobb angle Viewer – Cine/movie mode Viewer- Overlaying/ Hide or display overlay Viewer- Magnify | Similar¹ |
| Viewer – Measure Viewer – Inverting imagecolor Viewer – Cine Viewer- Overlaying. | Viewer- crop | |||
| 16. | 3D Cursor | Yes | Yes | Same |
| 17. | OptionalIntegration ofFDA-cleared3rd party AImodels | Yes | Yes | Same |
| 18. | Operation feature | Web environment-basedPACS.Viewing and handling DICOMmedical images. Review andreport study located on aserver. | Web environment-basedPACS.Viewing and handling DICOMmedical images. Review, modify,and approve the study located in aserver. | Same |
{7}------------------------------------------------
{8}------------------------------------------------
1Deep Tek's Augmento viewer offers a sharpening feature for enhanced image clarity, a specific function that QuickRad's viewer does not include.
QuickRad and DeepTek share extensive similarities in their core functionalities. Both systems are designed to manage radiology workflows effectively, supporting various modalities, resolution, image storage, and adhering to DICOM standards. They provide essential features such as study worklists, and software environments, making them comparable in many aspects.
Integration with AI models in QuickRad is optional, allowing users the flexibility to incorporate AI capabilities as needed. QuickRad supports the integration of the following FDA-cleared AI models from Qure AI, offering seamless functionality while displaying outputs "as-is":
- qXR: Chest X-ray interpretation (FDA 510(k) clearance: K231149) ●
- qCT LN Quant: Advanced lung nodule quantification for chest CT scans (FDA 510(k) clearance: K231149) .
- qER: AI for triaging intracranial hemorrhage and other conditions in CT scans (FDA 510(k) clearance: K212624)
These integrations ensure compliance with regulatory standards while enhancing diagnostic capabilities.
A key difference is that DeepTek's Augmento viewer includes a sharpening feature to enhance image clarity, which is not available in QuickRad's viewer. Despite this distinction, QuickRad maintains substantial equivalence to DeepTek in terms of overall performance and functionality. QuickRad offers comparable capabilities with added flexibility and adaptability, catering to diverse user needs.
The absence of the sharpening feature in QuickRad does not affectiveness and safety. QuickRad delivers robust performance with its flexible and adaptable platform, aligning well with DeepTek's offerings.
VII. NON-CLINICAL PERFORMANCE DATA
The non-clinical performance activities include:
- . Risk Management & Cybersecurity
- Device Hazard Analysis as per ISO 14971:2019 O
- Vulnerability Assessment & Penetration Testing (VAPT) based on OWASP Top 10. o
- . Usability Testing
- Formative and Summative Usability Testing per IEC 62366-1:2015 o
- Software Verification & Validation
- Unit Testing based on Software Requirements Specifications (SRS) O
{9}------------------------------------------------
- Integration Testing for interaction between software components o
- System Testing covering end-to-end functionality O
- Validation based on User Requirements Specifications (URS) o
- . Measurement Study
- Establishing equivalence with FDA-cleared viewer O
- . 3rd Party AI Model Integration Interface Testing
Non-clinical testing consisted of:
- · QuickRad underwent a thorough hazard analysis, addressing both intentional risks in compliance with ISO 14971:2019. Strategies to mitigate these risks were implemented to ensure safety throughout the device lifecycle, and the hazard analysis and mitigation strategies were validated, confirming QuickRad's compliance with ISO 14971:2019.
- · Periodic VAPT by third-party consultants were conducted to verify the adequacy of QuickRad's security controls, effectively mitigating potential cybersecurity risks.
- · Usability testing, conducted in compliance with IEC 62366-1:2015, included both formative and summative evaluations.
- · Unit testing verified core functional components were independently tested, ensuring QuickRad's units work as intended, with code correctness validated. Integration testing confirmed seamless interaction between software components and external systems, while system testing validated end-to-end functionality across all features. User Acceptance Testing verified QuickRad meets its intended use, ensuring adherence to the user requirement specifications documents through end-user validation. The test cases were addressfully passed the acceptance criteria.
- · Integration testing for QuickRad validated seamless end functionality across its software components, including APIs, OTS/SOUP components detailed in the SBOM, independent libraries, and DICOM interfaces. System testing encompassed core functionalities such as user management. DICOM viewer operations, search capabilities, radiologist assignment workflows, report management, audit log tracking, error handling, and hospital management, ensuring robust performance and compliance with the system's defined specifications.
- · An angle measurement study was conducted using 12 X-ray images (AP Pelvic, AP Knee, Lateral Ankle), evaluated independently by two experienced radiologists. Angles spanning the 0° to 180° range were measured using QuickRad's Viewer and benchmarked against the FDA-cleared FlexView Diagnostic DICOM Viewer (K233226). Statistical analyses, including equivalence testing and T-tests, demonstrated that QuickRad's angle measurement tool is substantially equivalent to FlexView Diagnostic and produced clinically reliable angle assessments.
- · A study was conducted to validate measurement tools in QuickRad's Viewer. Length, rectangle, ellipse ROI, and probe measurements were evaluated on CT abdomen images, while reference line accuracy was assessed using MR spine and brain images. This comprehensive evaluation, encompassing diverse imaging modalities, confirmed that QuickRad delivers performance equivalent to the FDA-cleared FlexView Diagnostic DICOM Viewer (K233226), ensuring consistent, reliable, and clinically accurate measurements across the spectrum of diagnostic imaging.
- · The integration interface between QuickRad and 3rd party AI models were tested to confirm that the integrity of the source DICOM file and output from Al models is unaltered and hence, does not get impacted when the source file is sent to the AI model for findings and the AI model sends the output to QuickRad through the interface.
The standards applicable as per Recognized Consensus Standards are as follows:
- · ISO 13485: 2016 Edition 3- Quality Management Systems for Medical Devices
- · IEC 62304 Edition 1.1 2015-06 Consolidated Version Medical device software life cycle processes.
- · IEC 62366-1:2015: Medical Devices 1: Application of usability engineering to medical devices.
- · ISO 14971 Third Edition 2019-12 Medical Devices Application of risk management to medical devices.
- · NEMA PS 3.1 3.20 2023e Digital Imaging and Communications in Medicine (DICOM) Set.
{10}------------------------------------------------
- · IEC ISO 10918-1 First edition 1994-02-15 Information technology Digital compression and coding of continuous-tone still images: Requirements and guidelines [Including Technical Corrigendum 1 (2005)].
VIII. CONCLUSION
The subject device, QuickRad, and the predicate device, DeepTek (K222781), have similar indications for use, technological characteristics, and principles of operation. After a careful evaluation of the technological features and non-clinical performance testing, it is evident that QuickRad is as safe and effective as DeepTek. Furthermore, QuickRad does not introduce any new concerns related to safety or effectiveness. Hence, QuickRad is considered substantially equivalent to DeepTek.