K Number
K091851

Validate with FDA (Live)

Date Cleared
2009-12-28

(189 days)

Product Code
Regulation Number
880.6250
Age Range
All
Reference & Predicate Devices
N/A
Predicate For
N/A
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
Intended Use

This glove is a disposable device intended for medical purposes that is worn on the examiner's hand to prevent contamination between patient and examiner. This glove has been tested for use with specific chemotherapy drugs listed below.

Device Description

Sterile, Powder Free Nitrile Examination Gloves, Blue Tested For Use With Chemotherapy Drugs.

AI/ML Overview

The provided document is a 510(k) premarket notification decision letter for Sterile, Powder Free Nitrile Examination Gloves, Blue, tested for use with chemotherapy drugs. It does not describe an AI/ML powered device, therefore, the information requested in the prompt related to acceptance criteria and studies for such devices cannot be extracted.

The document discusses the substantial equivalence determination for nitrile examination gloves to legally marketed predicate devices. The "Indications for Use" section lists specific chemotherapy drugs and their respective permeation (breakthrough detection) times when tested with the gloves.

Information that CAN be extracted, reorganized from the "Indications for Use" section:

1. A table of specific performance data (permeation times) for the device:

Chemotherapy DrugConcentrationPermeation (Breakthrough Detection Time in Minutes)
Dacarbazine (DTIC)10.0 mg/mL> 240
Mitomycin C5.0 mg/mL> 240
Carmustine (BCNU)3.3 mg/mL3.57
Cyclophosphamide (Cytoxan)20.0 mg/mL> 240
Doxorubicin Hydrochloride2.0 mg/mL> 240
5-Fluorouracil50.0 mg/mL> 240
Cisplatin1.0 mg/mL> 240
Etoposide20.0 mg/mL> 240
Paclitaxel (Taxol)6.0 mg/mL> 240
Thio-Tepa10.0 mg/mL24.39
Vincristine Sulfate50.0 mg/mL> 240
Methotrexate25.0 mg/mL> 240
Mitoxantrone100.0 mg/mL> 240
Ifosfamide (Ifex)50.0 mg/mL> 240
Warning on Labeling: Do Not Use with Thiotepa and Carmustine

Note: The document does not explicitly state the "acceptance criteria" as a single defined threshold for all drugs, but rather presents the measured performance against a listed set of chemotherapy drugs. The determination of "substantial equivalence" implies that the observed permeation times are considered acceptable compared to predicate devices for the indicated use. The warnings for Thiotepa and Carmustine indicate that the performance for these drugs was deemed insufficient for safe use, despite having measured breakthrough times.

The following information cannot be extracted from the provided text as it pertains to AI/ML device studies, which is not the subject of this document:

  1. Sample size used for the test set and the data provenance.
  2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts.
  3. Adjudication method for the test set.
  4. If a multi reader multi case (MRMC) comparative effectiveness study was done.
  5. If a standalone (i.e. algorithm only without human-in-the loop performance) was done.
  6. The type of ground truth used (expert consensus, pathology, outcomes data, etc).
  7. The sample size for the training set.
  8. How the ground truth for the training set was established.

{0}------------------------------------------------

Image /page/0/Picture/1 description: The image shows the seal of the Department of Health & Human Services (HHS) of the United States. The seal features the department's name arranged in a circular pattern around the perimeter. In the center is a stylized caduceus symbol, which is often associated with healthcare and medicine.

Food and Drug Administration 10903 New Hampshire Avenue Document Control Room W-066-0609 Silver Spring, MD 20993-0002

Mr. Cho Sow Fong Quality Assurance Manager GX Corporation SDN BHD Lot 6491-A, Batu 5%, Sementa, Off Jalan Kapar, 42100 Klang Selangor Darul Ehsan MALAYSIA

DEC 2 8 2009

Re: K091851

Trade/Device Name: Sterile, Powder Free Nitrile Examination Gloves, Blue Tested for with Chemotherapy Drugs Regulation Number: 880.6250 Regulation Name: Patient Examination Glove ... Regulatory Class: 1 Product Code: LZA, LZC Dated: December 15, 2009 Received: December 17, 2009

Dear Mr. Fong:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

{1}------------------------------------------------

Page 2- Mr. Fong

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to

http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to

http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.

Sincerely yours,

Anthony O. Rutan

Anthony D. Watson, BS, MS, MBA Director Division of Anesthesiology, General Hospital, Infection Control, and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health

{2}------------------------------------------------

Indications for Use

510(k) Number (if known): K091851

Device Name: Sterile, Powder Free Nitrile Examination Gloves, Blue Tested For Use With Chemotherapy Drugs.

Indication For Use:

This glove is a disposable device intended for medical purposes that is worn on the examiner's hand to prevent contamination between patient and examiner. This glove has been tested for use with specific chemotherapy drugs listed below.

Chemotherapy Drug Permeation (Breakthrough Detection Time in Minutes)

Dacarbazine (DTIC) (10.0 mg/mL)
Mitomycin C (5.0 mg/mL)
Carmustine (BCNU) (3.3 mg/mL)
Cyclophosphamide (Cytoxan) (20.0 mg/mL)
Doxorubicin Hydrochloride (2.0 mg/mL)
5-Fluorouracil (50.0 mg/mL)
Cisplatin (1.0 mg/mL)
Etoposide (20.0 mg/mL)
Paclitaxel (taxol) (6.0 mg/mL)
Thio-Tepa (10.0 mg/mL)
Vincristine Sulfate (50.0 mg/mL)
Methotrexate (25.0 mg/mL)
Mitoxantrone (100.0 mg/mL)
Ifosfamide (Ifex) (50.0 mg/mL)

Warning: Do Not Use with Thiotepa and Carmustine

  • Prescription Use -(Part 21 CFR 801 Subpart D)
    Over-The-Counter Use _ (21 CFR 801 Subpart C)

240 > 240 3.57 > 240 > 240 > 240 > 240 > 240 > 240 24.39 > 240 > 240 > 240 > 240

(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE (F NEEDED)

AND/OR

Concurrence of CDRH, Office Of Device Evaluation (ODE)

Elizabet P. Clauss-Will

(Division Sign-Off) (Division of Anesthesiology, General Heapital Infection Control, Dental Devices

Page 1 of

510(k) Number: K09183

§ 880.6250 Non-powdered patient examination glove.

(a)
Identification. A non-powdered patient examination glove is a disposable device intended for medical purposes that is worn on the examiner's hand or finger to prevent contamination between patient and examiner. A non-powdered patient examination glove does not incorporate powder for purposes other than manufacturing. The final finished glove includes only residual powder from manufacturing.(b)
Classification. Class I (general controls). The device, when it is a finger cot, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 880.9.