(200 days)
Posterior Components: When used as posterior pedicle screw fixation system in skeletally mature patients, the Synthes USS, including the Click'X and USS VAS components, and the Dual-Opening USS and Synthes Small Stature USS (which includes small stature), is intended to provide immobilization and stabilization of spinal segments as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar and sacral spine: degenerative disc disease (as defined as back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), degenerative spondylolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, failed previous spinal fusion, and pseudoarthrosis. When treating patient's with Degenerative Disc Disease (DDD), transverse bars are not cleared for use as part of the posterior pedicle screw construct. In addition, in skeletally mature patients, the Synthes USS, including the Click'X and USS VAS components and the Dual-Opening USS and Small Stature USS (which includes small stature and pediatric patients) is intended for the treatment of severe spondylolisthesis (grade 3 and 4) of the L5-S1 vertebra in patients receiving fusion by autogenous bone graft having implants attached to the lumbar and sacral spine with removal of the implants after the attainment of a solid fusion. The levels of pedicle screw fixation are L3-S2/ilium. When used as a posterior non-pedicle screw fixation system, in skeletally mature patients, the Synthes USS, and the Dual-Opening and Small Stature USS (which includes small stature and pediatric patients) are intended for the treatment of degenerative disc disease (as defined as back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), spinal stenosis, spondylolisthesis, spinal deformities (i.e., scoliosis. kyphosis, and/or lordosis, Scheuermann's Disease) fracture, pseudoarthrosis, tumor resection, and/or failed previous fusion.
Anterior Components: When used as an anteriolateral system, in skeletally mature patients, the Synthes USS, Dual-Opening USS and Small Stature USS (which includes small stature and pediatric patients), is intended for anteriolateral screw and/or staple fixation for the following indications: degenerative disc disease (as defined as back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), spinal stenosis, spondylolisthesis, spinal deformities (i.e., scoliosis, kyphosis, and/or lordosis), fracture or dislocation of the thoracolumbar spine, pseudoarthrosis, tumor resection, and/or failed previous fusion (levels T8-L5). In addition, when used with 3.5/6.0 mm parallel connectors, the Synthes USS can be linked to the CerviFix™ System. When used with 5.0/6.0 mm parallel connectors the Small Stature USS can be linked to the USS and Dual-Opening USS.
Synthes USS. Click'X. USS VAS. Small Stature and Dual-Opening Systems are multi-component systems comprised of rods (5.0mm and 6.0mm), screws (sideopening, dual-opening and dual core) and hooks (side opening and dual opening), transconnectors, transverse bars, parallel connectors, collars, nuts, staples and washers.
I am sorry, but the provided text does not contain information about the acceptance criteria or a study proving that a device meets those criteria.
The document is a 510(k) summary for a medical device called "Synthes USS, Click'X, USS VAS, Small Stature and Dual-Opening Systems". It describes the device, its components (rods, screws, hooks, etc.), and its indications for use as a spinal fixation system.
The core of the document is the FDA's letter granting premarket notification (510(k)) clearance, indicating that the device is substantially equivalent to legally marketed predicate devices. This regulatory document does not typically include detailed performance data, sample sizes, ground truth establishment, or clinical study results in the manner requested.
Therefore, I cannot provide:
- A table of acceptance criteria and reported device performance.
- Sample sizes or data provenance for a test set.
- Number and qualifications of experts for ground truth.
- Adjudication method for a test set.
- MRMC comparative effectiveness study results.
- Standalone algorithm performance.
- Type of ground truth used.
- Sample size for the training set.
- How ground truth for the training set was established.
{0}------------------------------------------------
۲ Abt Up L
10.1 510(K) SUMMARY
MAR 2 4 2003
DESCRIPTION
Synthes USS. Click'X. USS VAS. Small Stature and Dual-Opening Systems are multi-component systems comprised of rods (5.0mm and 6.0mm), screws (sideopening, dual-opening and dual core) and hooks (side opening and dual opening), transconnectors, transverse bars, parallel connectors, collars, nuts, staples and washers.
INDICATIONS
Posterior Components
When used as posterior pedicle screw fixation system in skeletally mature patients, the Synthes USS, including the Click'X and USS VAS components, and the Dual-Openinq USS and Synthes Small Stature USS (which includes small stature), is intended to provide immobilization and stabilization of spinal segments as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar and sacral spine: degenerative disc disease (as defined as back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), degenerative spondylolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, failed previous spinal fusion, and pseudoarthrosis.
When treating patient's with Degenerative Disc Disease (DDD), transverse bars are not cleared for use as part of the posterior pedicle screw construct.
In addition, in skeletally mature patients, the Synthes USS, including the Click'X and USS VAS components and the Dual-Opening USS and Small Stature USS (which includes small stature and pediatric patients) is intended for the treatment of severe spondylolisthesis (grade 3 and 4) of the L5-S1 vertebra in patients receiving fusion by autogenous bone graft having implants attached to the lumbar and sacral spine with removal of the implants after the attainment of a solid fusion. The levels of pedicle screw fixation are L3-S2/ilium.
When used as a posterior non-pedicle screw fixation system, in skeletally mature patients, the Synthes USS, and the Dual-Opening and Small Stature USS (which includes small stature and pediatric patients) are intended for the treatment of degenerative disc disease (as defined as back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), spinal stenosis, spondylolisthesis, spinal deformities (i.e., scoliosis. kyphosis, and/or lordosis, Scheuermann's Disease) fracture, pseudoarthrosis, tumor resection, and/or failed previous fusion.
{1}------------------------------------------------
Anterior Components
When used as an anteriolateral system, in skeletally mature patients, the Synthes USS, Dual-Opening USS and Small Stature USS (which includes small stature and pediatric patients), is intended for anteriolateral screw and/or staple fixation for the following indications: degenerative disc disease (as defined as back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), spinal stenosis, spondylolisthesis, spinal deformities (i.e., scoliosis, kyphosis, and/or lordosis), fracture or dislocation of the thoracolumbar spine, pseudoarthrosis, tumor resection, and/or failed previous fusion (levels T8-L5).
In addition, when used with 3.5/6.0 mm parallel connectors, the Synthes USS can be linked to the CerviFix™ System. When used with 5.0/6.0 mm parallel connectors the Small Stature USS can be linked to the USS and Dual-Opening ાકર.
{2}------------------------------------------------
Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is a stylized image of three human profiles facing right, with flowing lines representing hair or clothing.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
MAR 2 4 2003
Ms. Vikki M. Hoffman Senior RA Associate Synthes Spine 1690 Russell Road Paoli, Pennsylvania 19301
K022949 Re:
Trade Name: Synthes USS, Click X, USS VAS, Dual-Opening USS and Small Stature ાડદ Regulation Number: 21 CFR 888.3070, 888.3060, and 888.3050
Regulation Name: Pedicle Screw Spinal System, Spinal Interlaminal Fixation Orthosis, and Spinal Intervertebral Body Fixation Orthosis Regulatory Class: III Product Code: MNI, MNH, KWP, KWP, KWQ Dated: December 23, 2002 Received: December 24, 2002
Dear Ms. Hoffman:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set
{3}------------------------------------------------
Page 2 - Ms. Vikki M. Hoffman
forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (301) 594-4659. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html.
Sincerely yours,
Mark N. Millkern
Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
3.0FDA INDICATIONS FOR USE FORM
510(k) Number (if known): K 022949
Synthes USS, Click'X, USS VAS, Dual-Opening USS and Device Name: Small Stature USS Systems
INDICATIONS FOR USE:
Posterior Components
When used as posterior pedicle screw fixation system in skeletally mature patients, the Synthes USS, including the Click'X and USS VAS components, and the Dual-Opening USS and Synthes Small Stature USS (which includes small stature), is intended to provide immobilization and stabilization of spinal seqments as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar and sacral spine: degenerative disc disease (as defined as back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), degenerative spondylolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, failed previous spinal fusion, and pseudoarthrosis.
When treating patient's with Degenerative Disc Disease (DDD), transverse bars are not cleared for use as part of the posterior pedicle screw construct.
In addition, in skeletally mature patients, the Synthes USS, including the Click'X and USS VAS components and the Dual-Opening USS and Small Stature USS (which includes small stature and pediatric patients) is intended for the treatment of severe spondvlolisthesis (grade 3 and 4) of the L5-S1 vertebra in patients receiving fusion by autogenous bone graft having implants attached to the lumbar and sacral spine with removal of the implants after the attainment of a solid fusion. The levels of pedicle screw fixation are L3-S2/ilium.
When used as a posterior non-pedicle screw fixation system, in skeletally mature patients, the Synthes USS, and the Dual-Opening and Small Stature USS (which includes small stature and pediatric patients) are intended for the treatment of degenerative disc disease (as defined as back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), spinal stenosis, spondylolisthesis, spinal deformities (i.e., scoliosis. kyphosis, and/or lordosis, Scheuermann's Disease) fracture, pseudqgarthrosis, tumor resection, and/or failed previous fusion
Mark
(Division Sign-Om
Divion of General. Restorative
and Neurological Devices
510 Number K022949,
10F=
{5}------------------------------------------------
Anterior Components
When used as an anteriolateral system, in skeletally mature patients, the Synthes USS, Dual-Opening USS and Small Stature USS (which includes small stature and pediatric patients), is intended for anteriolateral screw and/or staple fixation for the following indications: degenerative disc disease (as defined as back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), spinal stenosis, spondylolisthesis, spinal deformities (i.e., scoliosis, kyphosis, and/or lordosis), fracture or dislocation of the thoracolumbar spine, pseudoarthrosis, tumor resection, and/or failed previous fusion (levels T8-L5).
In addition, when used with 3.5/6.0 mm parallel connectors, the Synthes USS can be linked to the CerviFix™ System. When used with 5.0/6.0 mm parallel connectors the Small Stature USS can be linked to the USS and Dual-Opening uss.