Found 166 results

510(k) Data Aggregation

    K Number
    K260104

    Validate with FDA (Live)

    Date Cleared
    2026-02-04

    (22 days)

    Product Code
    Regulation Number
    888.3660
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Additional Product Codes:**

    • KWT- Shoulder joint metal/polymer non-constrained cemented prosthesis (21 CFR 888.3650
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Signature™ ONE System is indicated, based on patient-specific radiological images with identifiable placement anatomical landmarks, to assist in pre-operative planning and/or intra-operative guiding of surgical instruments for shoulder replacement surgical procedures on patients not precluded from being radiologically scanned.

    The Signature™ ONE System is designed for use on a skeletally mature patient population. The targeted population has the same characteristics as the population that is suitable for the implants compatible with the Signature™ ONE System.

    The Signature™ ONE System is to be used with the glenoid components of the following shoulder implant systems in accordance with their indications and contraindications: Zimmer® Trabecular Metal Reverse Plus® Shoulder, Comprehensive® Total Shoulder System, Comprehensive® Reverse Shoulder System, Comprehensive® Reverse Augmented Baseplates and Alliance® Glenoid System.

    The Signature™ ONE System pre-operative planning is also compatible with the humeral components of the following shoulder implant systems in accordance with their indications and contraindications: Comprehensive® Total Shoulder System, Comprehensive® Reverse Shoulder System, and Identity™ Shoulder System.

    The Signature™ ONE System Guides and bone models are intended for single use only.

    Device Description

    The Signature™ ONE System is developed to assist in preoperative planning (using the Signature™ ONE Planner) and to accurately transfer a pre-operative plan to orthopedic surgical procedures (using the Signature™ ONE Guides and bone model) if desired in skeletally mature individuals for Total Shoulder Arthroplasty. Both anatomic and reverse (TSA and RSA respectively) approaches are supported.

    The Signature ONE Guides and Bone Models are designed and manufactured of polyamide (nylon) using additive manufacturing selective laser sintering (SLS), based on the approved/finalized pre-surgical plan and shipped prior to surgery. The guides and bone models are provided non-sterile and sterilized at the hospital. They are used intra-operatively to assist the surgeon in reproducing the plan on the scapula. The Signature ONE System surgical technique remains close to the conventional shoulder arthroplasty workflow.

    The Signature™ ONE System uses a Non-Device Medical Device Data System (MDDS) called the Zimmer Biomet Portal for the interaction with external users (i.e. imaging technician and the surgeon). The internal users (i.e. the Zimmer Biomet operators) use manufacturing software applications to prepare the patient cases for the surgeon.

    The purpose of the submission is that the CT Reconstruction internal software application was updated with an improved AI/ML locked model for automatic segmentation and also retraining the model with new production grade scapula and humerus CT segmentations. The AI/ML model is used in the Segmentation step only within the CT Reconstruction internal software application prior to manual segmentation performed by the Zimmer Biomet operator. The use of AI has not changed since predicate K232425. In addition, the Landmarking step within the internal software application was updated with option to select additional configurable landmarks in the Planning application (used to determine the reference coordinate systems to provide native bone information).

    AI/ML Overview

    The provided FDA 510(k) clearance letter for the Signature™ ONE System does not contain a detailed study with specific acceptance criteria, reported performance, or comprehensive information about the data used for testing and training. This document focuses on demonstrating substantial equivalence to a predicate device, K232425 Signature™ ONE System.

    The information regarding acceptance criteria and the study that proves the device meets them is very limited in this document. The submission states that "Performance tests documented to ensure the performance of the implemented features and verify related design inputs" were conducted, but does not provide details of these tests or their results.

    Here's an attempt to extract and infer the requested information based on the provided text, highlighting what is missing:


    Acceptance Criteria and Device Performance Study for Signature™ ONE System (AI/ML Segmentation Update)

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategorySpecific Metric/Description (Inferred)Reported Device Performance
    AI/ML SegmentationAccuracy, precision, recall for automatic segmentation of scapula and humerus CT images.Not explicitly stated. The document indicates the model was "retrained with new production grade scapula and humerus CT segmentations" and is "used in the Segmentation step only within the CT Reconstruction internal software application prior to manual segmentation performed by the Zimmer Biomet operator." This implies sufficient performance to assist operators, but no quantitative metrics are provided.
    LandmarkingCorrect placement and configuration of additional landmarks in the Planning application.Not explicitly stated. The document notes "additional configurable landmarks" were added, and it "uses existing landmarks to determine the reference coordinate systems." This suggests functionality was verified, but no specific performance targets or results are given.
    Overall System PerformancePerformance of implemented features and verification of related design inputs, in line with prior predicate device performance."Performance tests documented to ensure the performance of the implemented features and verify related design inputs." No specific results or metrics are given.
    Usability EngineeringPerformance regarding human factors engineering."This remains unchanged and applicable from the predicate K232425." No specific results are provided.
    ValidationRelated user needs, intended use, safety, and effectiveness."Validation performed to validate related user needs, intended use and safety and effectiveness. This remains unchanged and applicable from the predicate K232425." No specific results are provided.
    Software Verification and ValidationAdherence to IEC 62304 and FDA guidance for software functions, demonstrating no new safety/effectiveness questions."The testing demonstrates that the Signature™ ONE System does not raise any different questions of safety and effectiveness as compared to the predicate devices." No specific tests or results detailed.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size for Test Set: Not specified. The document mentions the AI/ML model was "retrained with new production grade scapula and humerus CT segmentations" and previous "humerus scans were exploratory quality." This implies a test set was used to establish the "new production grade" status, but the exact size is not provided.
    • Data Provenance: Not specified. It only mentions "production grade scapula and humerus CT segmentations." The country of origin and whether the data is retrospective or prospective are not mentioned.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Their Qualifications

    • Number of Experts: Not specified.
    • Qualifications of Experts: Not specified.

    4. Adjudication Method for the Test Set

    • Adjudication Method: Not specified.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • Was an MRMC study done? No, the document does not mention an MRMC comparative effectiveness study where human readers improve with AI vs. without AI assistance. The AI/ML model is described as assisting "prior to manual segmentation performed by the Zimmer Biomet operator," implying an assistive role, but no comparative study is detailed.

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study

    • Was a standalone study done? Not explicitly stated as a standalone "study." The language "used in the Segmentation step only (...) prior to manual segmentation" suggests the AI performs segmentation independently before human review/modification, but its standalone performance metrics are not provided. The overall system is described as having manual segmentation by an operator after the AI step.

    7. Type of Ground Truth Used

    • Type of Ground Truth: The document refers to "new production grade scapula and humerus CT segmentations." This implies that the ground truth for segmentation was established by expert review and/or manual segmentation deemed as high quality (i.e., "production grade"). It does not specify if this was expert consensus, pathology, or outcomes data.

    8. Sample Size for the Training Set

    • Sample Size for Training Set: Not specified. The document states the model was "retrained with new production grade scapula and humerus CT segmentations." The size of this new training set is not provided.

    9. How the Ground Truth for the Training Set Was Established

    • How Ground Truth Was Established: The ground truth for the training set was established through "production grade scapula and humerus CT segmentations." This suggests that human experts (likely trained Zimmer Biomet operators or clinicians) performed manual segmentations that were then refined and verified to a high standard, serving as the ground truth for training the AI/ML model.
    Ask a Question

    Ask a specific question about this device

    K Number
    K250713

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-12-01

    (266 days)

    Product Code
    Regulation Number
    888.3650
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Humeral Reconstruction Prosthesis; Equinoxe® Stemless Shoulder Implants
    Regulation Number: 21 CFR 888.3650
    Humeral Reconstruction Prosthesis; Equinoxe® Stemless Shoulder Implants
    Regulation Number: 21 CFR 888.3650
    Classification Name:** Shoulder joint metal/polymer non-constrained cemented prosthesis

    Regulation Number: 888.3650

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Humeral Reconstruction Prosthesis

    The Equinoxe® Humeral Reconstruction Prosthesis System is intended for use in hemi or total shoulder arthroplasty where proximal humeral resection is deemed necessary in cases of:

    • Non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis
    • Rheumatoid arthritis
    • Revision where other devices or treatments have failed
    • Correction of functional deformity
    • Treatment of acute or chronic fracture with humeral head involvement, which are unmanageable using other treatment
    • Traumatic arthritis
    • Oncology applications including bone loss due to tumor resection.
    • Significant humeral resection which are unmanageable using other treatment methods

    The Equinoxe® Humeral Reconstruction Prosthesis System can be used in either primary or revision arthroplasty procedures.

    The Equinoxe® Humeral Reconstruction Prosthesis System is indicated for proximal humeral replacement in conjunction with reverse shoulder arthroplasty in which significant resection of the proximal humerus is necessary, the rotator cuff is irreplaceable and grossly deficient, and a functional deltoid muscle is present.

    In the USA, the Equinoxe® Humeral Reconstruction Prosthesis System is not indicated for use with the Equinoxe Reverse Shoulder System components in oncology applications.

    The Equinoxe® Humeral Reconstruction Prosthesis Distal Stems are for cemented use only, while the HA coated Equinoxe® Humeral Reconstruction Prosthesis Distal Stem Collars are only for uncemented, press-fit use.

    Stemless Shoulder

    The Equinoxe® Stemless Shoulder System is indicated for use in skeletally mature individuals with degenerative diseases of the glenohumeral joint where anatomic total shoulder arthroplasty is determined by the surgeon to be the preferred method of treatment. Clinical indications for anatomic total shoulder arthroplasty are as follows:

    • Osteoarthritis, osteonecrosis or post-traumatic degenerative problems.
    • Congenital abnormalities in the skeletally mature.
    • Primary and secondary necrosis of the humeral head.
    • Pathologies where arthrodesis or resectional arthroplasty of the humeral head are not acceptable.
    • Revisions of humeral prostheses when other treatments or devices have failed (where adequate fixation can be achieved).
    • To restore mobility from previous procedures (e.g. previous fusion).

    The Equinoxe® Stemless Shoulder humeral components are indicated for press-fit, uncemented use.

    The Equinoxe® Stemless Shoulder System is intended to be used with the cemented Equinoxe® glenoid components.

    Device Description

    Humeral Reconstruction Prosthesis

    The Exactech Equinoxe Humeral Reconstruction Prosthesis is designed to replace both the articulating surface of the shoulder (humeral head) as well as resected humerus. The modular design of the system allows for a surgeon to construct the middle and proximal segments of the prosthesis in various lengths in order to match the length of resected bone and maintain the natural arm length of the patient.

    The prosthesis is manufactured from Ti-6Al-4V and has both Titanium Plasma Spray and HA coated regions. The proximal bodies are available in five sizes (Extra-Small, Small, Medium, Large, Extra-Large) and two lengths (+0mm, +12.5mm). The middle segments are available in 3 lengths (25mm, 50mm, 75mm) with one diameter. The distal stems are available in 3 lengths (80mm, 120mm, 200mm) and 6 diameters (6mm, 7mm, 8mm, 9mm, 11mm, 13mm). The distal stem collars are available in 17 diameters (17.5mm-33.5mm, 1mm increments). The distal stem collars are intended for press-fit fixation. The proximal bodies and middle segments have suture throughholes to facilitate soft tissue attachment.

    Stemless Shoulder

    The Equinoxe Stemless Shoulder is intended to be used with Exactech glenoid components for use in Total Shoulder Arthroplasty. The Equinoxe Stemless Shoulder includes humeral components and humeral heads. The Equinoxe Stemless Humeral Components are additively manufactured from Titanium Alloy and have porous regions. The Stemless Humeral Heads are made from Cobalt Chrome Alloy. The Equinoxe Stemless Humeral Components are available in 3 sizes, and the Stemless Humeral Heads are available in available in 12 sizes, with diameters between 36mm and 53mm and two height options (Extra Short, Short).

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251686

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-10-30

    (150 days)

    Product Code
    Regulation Number
    888.3650
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Name:** Tornier Humeral Reconstruction System Max (Tornier HRS Max)
    Regulation Number: 21 CFR 888.3650
    Name** | Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented |
    | Regulation Number | 888.3650

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    In Anatomic:

    Tornier HRS Max humeral assembly can be used for anatomic arthroplasty when used with a humeral head. It can be used as a hemiarthroplasty, if the natural glenoid provides a sufficient bearing surface, or in conjunction with a glenoid, as a total replacement.

    Tornier HRS Max is indicated for use as a replacement of shoulder joints for patients with a functional deltoid muscle and with an intact or reconstructable rotator cuff with pain disabled by:

    • Rheumatoid arthritis
    • Non-inflammatory degenerative joint disease (i.e., osteoarthritis and avascular necrosis)
    • Fractures of the humeral head
    • Post-Traumatic arthritis
    • Oncology applications including bone loss due to tumor resection
    • Significant humeral resection where adequate fixation can be achieved

    In Reverse:

    Tornier HRS Max is indicated for use as a replacement of shoulder joints for patients with a functional deltoid muscle and with massive and non-repairable rotator cuff-tear with pain disabled by:

    • Rheumatoid arthritis
    • Non-inflammatory degenerative joint disease (i.e. osteoarthritis and avascular necrosis)
    • Correction of functional deformity
    • Fractures of the humeral head
    • Post-Traumatic arthritis
    • Massive and non-repairable rotator cuff tear
    • Oncology applications including bone loss due to tumor resection.
    • Significant humeral resection where adequate fixation can be achieved

    The reversed tray and polyethylene insert are indicated for use in the conversion from an anatomic to reversed shoulder arthroplasty without the removal of a well-fixed humeral assembly during revision surgery for patients with a functional deltoid muscle.

    Notice:

    • All components are single-use.
    • The coated humeral stem is intended for cemented or cementless use
    • The all-poly glenoid components are intended for cemented use only.
    • The glenoid sphere implant is anchored to the bone with screws and is for non-cemented fixation.
    • Titanium humeral heads are intended for patients with suspected cobalt alloy material sensitivity. The wear properties of titanium and titanium alloys are inferior to that of cobalt alloy. A titanium humeral head is not recommended for patients who lack a suspected material sensitivity to cobalt alloy.
    Device Description

    The HRS Max System is designed to address massive proximal humeral bone loss and provide for deltoid wrapping. The modular functionality of the HRS Max Shoulder System allows clinicians to create constructs that can address unique anatomies which include proximal humeral bone loss, while also allowing for use in anatomic hemiarthroplasty or reversed configuration.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252416

    Validate with FDA (Live)

    Date Cleared
    2025-10-29

    (89 days)

    Product Code
    Regulation Number
    888.3660
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Shoulder joint metal/polymer non-constrained cemented prosthesis (21 CFR 888.3650) |
    | **Classification

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The AETOS Shoulder System (when used with the AETOS Humeral Meta Stems) is to be used only in patients with an intact or reconstructable rotator cuff, where it is intended to provide increased mobility and stability and to relieve pain.

    The AETOS humeral stems (AETOS Humeral Meta Stems) and head may be used by themselves, as a hemiarthroplasty, if the natural glenoid provides a sufficient bearing surface, or in conjunction with the glenoid, as a total replacement.

    When used with the AETOS Humeral Meta Stems, The AETOS Shoulder System is indicated for use as a replacement of shoulder joints disabled by:

    • Rheumatoid arthritis
    • Non-inflammatory degenerative joint disease
    • Correction of functional deformity
    • Fractures of the humeral head
    • Traumatic arthritis
    • Revision of other devices if sufficient bone stock remains

    The AETOS Shoulder System (when used with AETOS Stemless Humeral Prosthesis) is to be used only in patients with an intact or reconstructable rotator cuff.

    When used with AETOS Stemless Humeral Prosthesis, the AETOS Shoulder System is indicated for anatomic total shoulder replacement of shoulder joints disabled by:

    • Non-inflammatory degenerative joint disease
    • Traumatic arthritis
    • Revision of other devices if sufficient bone stock remains

    The coated humeral components are intended for uncemented use. The glenoid component is intended for cemented use only.

    In Reverse:

    The AETOS Shoulder System, when used with AETOS Humeral Meta Stems, is indicated for use as a replacement of shoulder joints for patients with a functional deltoid muscle and with massive and non-repairable rotator cuff-tear with pain disabled by:

    • Rheumatoid arthritis
    • Non-inflammatory degenerative joint disease
    • Correction of functional deformity
    • Fractures of the humeral head
    • Traumatic arthritis
    • Revision of devices if sufficient bone stock remains

    The humeral liner component is indicated for use in the AETOS Shoulder System as a primary reverse total shoulder replacement and for use when converting an anatomic AETOS Shoulder System into a reverse shoulder construct. This facilitates the conversion without the removal of the humeral stem during revision surgery for patients with a functional deltoid muscle. The component is permitted to be used in the conversion from anatomic to reverse if the humeral stem is well fixed, the patient has a functional deltoid muscle; the arthroplasty is associated with a massive and non-repairable rotator cuff tear.

    The coated humeral stems are indicated for uncemented use. The coated glenoid base plate is intended for cementless application with the addition of screws for fixation.

    Note: All implant components are single use.

    Device Description

    The AETOS Shoulder System Meta Humeral Prosthesis Size 0 subject to this submission is intended for press-fit fixation as of an implant construct in anatomic and/or reverse total shoulder arthroplasty for the treatment of skeletally mature individuals with degenerative diseases of the glenohumeral joint.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252129

    Validate with FDA (Live)

    Date Cleared
    2025-10-03

    (88 days)

    Product Code
    Regulation Number
    888.3660
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Shoulder joint metal/polymer non-constrained cemented prosthesis (21 CFR 888.3650) |
    | **Classification

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The AETOS Shoulder System (when used with the AETOS Humeral Meta Stems) is to be used only in patients with an intact or reconstructable rotator cuff, where it is intended to provide increased mobility and stability and to relieve pain.

    The AETOS humeral stems (AETOS Humeral Meta Stems) and head may be used by themselves, as a hemiarthroplasty, if the natural glenoid provides a sufficient bearing surface, or in conjunction with the glenoid, as a total replacement.

    When used with the AETOS Humeral Meta Stems, The AETOS Shoulder System is indicated for use as a replacement of shoulder joints disabled by:

    • Rheumatoid arthritis
    • Non-inflammatory degenerative joint disease
    • Correction of functional deformity
    • Fractures of the humeral head
    • Traumatic arthritis
    • Revision of other devices if sufficient bone stock remains

    The AETOS Shoulder System (when used with AETOS Stemless Humeral Prosthesis) is to be used only in patients with an intact or reconstructable rotator cuff.

    When used with AETOS Stemless Humeral Prosthesis, the AETOS Shoulder System is indicated for anatomic total shoulder replacement of shoulder joints disabled by:

    • Non-inflammatory degenerative joint disease
    • Traumatic arthritis
    • Revision of other devices if sufficient bone stock remains

    The coated humeral components are intended for uncemented use. The glenoid component is intended for cemented use only.

    In Reverse:

    The AETOS Shoulder System, when used with AETOS Humeral Meta Stems, is indicated for use as a replacement of shoulder joints for patients with a functional deltoid muscle and with massive and non-repairable rotator cuff-tear with pain disabled by:

    • Rheumatoid arthritis
    • Non-inflammatory degenerative joint disease
    • Correction of functional deformity
    • Fractures of the humeral head
    • Traumatic arthritis
    • Revision of devices if sufficient bone stock remains

    The humeral liner component is indicated for use in the AETOS Shoulder System as a primary reverse total shoulder replacement and for use when converting an anatomic AETOS Shoulder System into a reverse shoulder construct. This facilitates the conversion without the removal of the humeral stem during revision surgery for patients with a functional deltoid muscle. The component is permitted to be used in the conversion from anatomic to reverse if the humeral stem is well fixed, the patient has a functional deltoid muscle; the arthroplasty is associated with a massive and non-repairable rotator cuff tear.

    The coated humeral stems are indicated for uncemented use. The coated glenoid base plate is intended for cementless application with the addition of screws for fixation.

    Device Description

    The AETOS Stemless Humeral Prosthesis subject to this submission is a humeral anchor intended for press-fit fixation as part of an implant construct in anatomic total shoulder arthroplasty for the treatment of skeletally mature individuals with degenerative diseases of the glenohumeral joint.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251098

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-08-11

    (123 days)

    Product Code
    Regulation Number
    888.3670
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented |
    | Regulation Number | 888.3670, 888.3650

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Hemiarthroplasty/Conventional Total Application:

    • Non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis.
    • Rheumatoid arthritis.
    • Correction of functional deformity.
    • Fractures of the proximal humerus, where other methods of treatment are deemed inadequate.
    • Difficult clinical management problems, including cuff arthropathy, where other methods of treatment may not be suitable or may be inadequate.

    Optional use in revision: in some medical conditions (e.g. revision when healthy and good bone stock exists), the surgeon may opt to use primary implants in a revision procedure.

    Reverse Application:
    Identity Revision Humeral Stem products are indicated for use in patients whose shoulder joint has a grossly deficient rotator cuff with severe arthropathy and/or previously failed shoulder joint replacement with a grossly deficient rotator cuff. The patient must be anatomically and structurally suited to receive the implants and a functional deltoid muscle is necessary.

    The Identity Revision Humeral Stem is indicated for primary, fracture, or revision total shoulder replacement for the relief of pain and significant disability due to gross rotator cuff deficiency.

    The assembled humeral component may be used alone for hemiarthroplasty or combined with the glenoid component or reverse components for total shoulder arthroplasty (conventional or reverse applications). The humeral components may be used cemented or uncemented (biological fixation).

    Device Description

    The Identity Revision Humeral Stems are comprised of titanium alloy. The diameters of the stems range in 1mm increments from 4mm to 18mm in a revision length of 133-134mm. The stem is designed with a distal portion that is cylindrical in shape with a tapered and a proximal portion that is flared, eight-sided shape. The devices have a machine finish distally and a plasma-spray titanium porous coating proximally. To support placement and bone reconstruction in fracture cases, the Identity Revision Humeral Stems feature proximal suture holes as well as etch lines for stem length respect to the native humeral head. The humeral stems employ an oval reverse taper which allows the attachment of either an Identity Humeral Stem Adapter for hemi- and anatomic total shoulder applications or an Identity Humeral Tray for reverse shoulder applications.

    AI/ML Overview

    I apologize, but the provided FDA 510(k) clearance letter for the "Identity Revision Humeral Stems" does not contain any information about acceptance criteria or a study that proves the device meets those criteria for software-related performance.

    This document is for a medical device (humeral stems, which are a type of orthopedic implant) and focuses on the mechanical, material, and design aspects of the device, comparing it to predicate devices to establish substantial equivalence.

    Specifically, the "Non-Clinical and/or Clinical Tests Summary & Conclusions" section lists:

    • Fatigue Testing
    • Range of Motion Analysis
    • Magnetic Resonance Imaging (MRI)

    It explicitly states: "No animal or clinical testing provided." This reinforces that the clearance is based on bench testing and comparison to existing devices, not on a human-in-the-loop study involving AI or a comprehensive performance study as you've described in your request.

    Therefore, I cannot fulfill your request for information regarding:

    1. A table of acceptance criteria and reported device performance (for AI-related metrics).
    2. Sample sizes for test sets or data provenance.
    3. Number of experts, qualifications, or adjudication methods for ground truth establishment.
    4. MRMC studies, effect sizes, or standalone algorithm performance.
    5. Type of ground truth used (expert consensus, pathology, outcomes data).
    6. Sample size for the training set or how its ground truth was established.

    This document pertains to a physical orthopedic implant, not a software or AI-driven diagnostic/therapeutic device that would typically involve the types of studies and acceptance criteria you've asked about.

    Ask a Question

    Ask a specific question about this device

    K Number
    K243448

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-08-01

    (267 days)

    Product Code
    Regulation Number
    888.3660
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Shoulder joint metal/polymer non-constrained cemented prosthesis

    Regulation Number: 888.3660, 888.3650

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Equinoxe Shoulder System is indicated for use in skeletally mature individuals with degenerative diseases or fractures of the glenohumeral joint where total or hemi-arthroplasty is determined by the surgeon to be the preferred method of treatment.

    • The cemented primary humeral stem, long/revision stem, fracture stems, and all Equinoxe glenoids are intended for cemented fixation.
    • The press-fit humeral stems are intended for press-fit applications but may be used with bone cement at the discretion the surgeon.
    • The reverse humeral components are intended to be used in cemented applications or in revision cases when the humeral component is well-fixed/stable, as deemed by the orthopaedic surgeon.
    • Humeral Heads are intended for use in cemented and press-fit applications.

    Clinical indications for the PRIMARY (P), LONG/REVISION (L), and FRACTURE (F) humeral components are as follows:

    PLFIndications
    Rheumatoid arthritis, osteoarthritis, osteonecrosis or post-traumatic degenerative problems
    Congenital abnormalities in the skeletally mature
    Primary and secondary necrosis of the humeral head.
    Humeral head fracture with displacement of the tuberosities
    Pathologies where arthrodesis or resectional arthroplasty of the humeral head are not acceptable
    Revisions of humeral prostheses when other treatments or devices have failed (where adequate fixation can be achieved)
    Displaced three-part and four-part upper humeral fractures
    Spiral and other fractures of the mid-humerus (in combination with glenohumeral degenerative diseases)
    Revision of failed previous reconstructions when distal anchorage is required
    To restore mobility from previous procedures (e.g. previous fusion)

    The Equinoxe Reverse Shoulder System is indicated for use in skeletally mature individuals with degenerative diseases of the glenohumeral joint and a grossly deficient, irreparable rotator cuff. The Equinoxe Reverse Shoulder is also indicated for a failed glenohumeral joint replacement with loss of rotator cuff function resulting in superior migration of the humeral head.

    The Equinoxe Platform Fracture Stem is indicated for use in skeletally mature individuals with acute fracture of the proximal humerus and displacement of the tuberosities, displaced 3- and 4-part fractures of the proximal humerus (hemi-arthroplasty), or acute fracture of the proximal humerus with failure of the glenohumeral joint (primary total shoulder arthroplasty). The Equinoxe Platform Fracture Stem is also indicated for acute fracture of the proximal humerus in combination with degenerative diseases of the glenohumeral joint and a grossly deficient, irreparable rotator cuff resulting in superior migration of the humeral head (reverse total shoulder arthroplasty). The Equinoxe Platform Fracture Stem is indicated for cemented use only.

    Device Description

    The proposed Equinoxe Activit-E Reverse Humeral Liners are humeral liners intended to be used in reverse total shoulder arthroplasty (rTSA) as a part of the Equinoxe® Shoulder System. The proposed devices are constructed of highly crosslinked UHMWPE containing vitamin E referred to as Activit-E. There are no proposed geometric or compatibility changes as compared to the predicate humeral liner devices cleared in K223833.

    AI/ML Overview

    The provided document is a 510(k) clearance letter and summary for a medical device, the Equinoxe® Shoulder System. This document focuses on the substantial equivalence of a new version of the device (specifically, the Humeral Liners made from Activit-E material) to a previously cleared predicate device.

    The FDA 510(k) clearance process is primarily focused on demonstrating substantial equivalence, not necessarily on proving that a device meets specific "acceptance criteria" in the same way one might for a diagnostic AI algorithm. Therefore, the information typically requested in an acceptance criteria study (like sample sizes for test and training sets, expert qualifications, ground truth establishment for AI, MRMC studies, or standalone algorithm performance) is not directly present in this regulatory submission for a physical orthopedic implant.

    However, I will extract the closest available information related to performance and testing, as well as explicitly state where the requested information is not provided.


    1. Table of Acceptance Criteria and Reported Device Performance

    For this specific medical device (Equinoxe® Shoulder System - Humeral Liners), the "acceptance criteria" are not reported as numerical thresholds like accuracy or sensitivity. Instead, the acceptance criteria are implicitly met by demonstrating that the new device performs "as intended" and is "substantially equivalent" to the predicate device through various non-clinical tests. The performance is assessed by confirming that the new Activit-E material does not negatively impact the mechanical integrity and biological interaction compared to the conventional UHMWPE.

    Acceptance Criterion (Implicit)Reported Device Performance
    Humeral Liner-Tray Fatigue: Demonstrate mechanical durability under cyclical loading.Testing performed, demonstrating performance. (Specific numerical results and acceptance levels are not detailed in this summary, but would have been part of the full submission).
    Humeral Liner-Tray Disassembly: Ensure secure attachment and resistance to accidental disassembly.Testing performed, demonstrating performance. (Specific numerical results and acceptance levels are not detailed in this summary).
    Humeral Liner Mode I Wear: Assess wear characteristics under simulated physiological conditions.Testing performed, demonstrating performance (including particle analysis). (Specific numerical results and acceptance levels are not detailed in this summary).
    Post-Wear Testing Particle Analysis (per ASTM F1877-05:2010): Characterize wear particles to assess potential biological impact.Testing performed, demonstrating performance. (Specific numerical results are not detailed in this summary).
    Biocompatibility (per ISO 10993-1:2018): Ensure the device material does not cause adverse biological reactions.Testing performed, demonstrating biocompatibility.
    Bacterial Endotoxins (per USP <161>, USP <85> and ANSI/AAMI ST72): Ensure sterility and absence of endotoxins.Testing performed, demonstrating compliance.
    Geometric & Compatibility Equivalence: No changes in geometry or compatibility with existing system components.Confirmed: "There are no proposed geometric or compatibility changes as compared to the predicate humeral liner devices cleared in K223833."

    2. Sample Sizes Used for the Test Set and the Data Provenance

    This information is typically not included in a 510(k) summary for a physical implant. The "test sets" here refer to the samples of the device components used for mechanical and biological testing.

    • Sample Size for Test Set: Not specified in the provided document (e.g., number of liners tested for fatigue, wear). These would be standard engineering test sample sizes as per relevant ASTM/ISO standards.
    • Data Provenance: Not specified. Non-clinical bench testing is typically performed in a controlled laboratory environment. Retrospective/prospective data or country of origin are not applicable in the same way as for clinical studies or AI algorithms.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications of Those Experts

    This information is not applicable and therefore not provided. For a physical implant like a shoulder system, "ground truth" is established through engineering specifications, material properties, and performance standards, not through expert consensus on interpretations like with medical images.

    4. Adjudication Method for the Test Set

    This information is not applicable and therefore not provided. Adjudication methods like 2+1 or 3+1 are used for expert review of clinical data (e.g., radiological images) to establish ground truth, which is not relevant for the bench testing of mechanical implants.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and the Effect Size

    This information is not applicable and therefore not provided. MRMC studies are used to assess the impact of a diagnostic aid (e.g., an AI algorithm) on human reader performance, which is not relevant for the clearance of an orthopedic implant.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Study Was Done

    This information is not applicable and therefore not provided. This device is a physical implant, not a software algorithm.

    7. The Type of Ground Truth Used

    The "ground truth" for the performance of the Equinoxe® Shoulder System Humeral Liners is established through industry-recognized performance standards (ASTM and ISO standards) and engineering specifications. These standards define acceptable limits for wear, fatigue, biocompatibility, and other mechanical and biological properties. Compliance with these standards, along with demonstration of equivalence to the predicate device, forms the basis of the safety and effectiveness claims.

    8. The Sample Size for the Training Set

    This information is not applicable and therefore not provided. This device is a physical implant, not an AI algorithm that requires a training set.

    9. How the Ground Truth for the Training Set Was Established

    This information is not applicable and therefore not provided.

    Ask a Question

    Ask a specific question about this device

    K Number
    K250848

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-07-02

    (104 days)

    Product Code
    Regulation Number
    888.3670
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    prosthesis (21 CFR 888.3670)

    • KWT - Shoulder joint metal/polymer nonconstrained cemented prosthesis (21 CFR 888.3650
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Hemiarthoplasty/Conventional Total Application:

    • Non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis.
    • Rheumatoid arthritis.
    • Correction of functional deformity.
    • Fractures of the proximal humerus, where other methods of treatment are deemed inadequate.
    • Difficult clinical management problems, including cuff arthropathy, where other methods of treatment may not be suitable or may be inadequate.

    Optional use in revision: in some medical conditions (e.g. revision when healthy and good bone stock exists), the surgeon may opt to use primary implants in a revision procedure.

    Reverse Application:

    Zimmer Biomet Reverse Shoulder products are indicated for use in patients whose shoulder joint has a grossly deficient rotator cuff with severe arthropathy and/or previously failed shoulder joint replacement with a grossly deficient rotator cuff. The patient must be anatomically and structurally suited to receive the implants, and a functional deltoid muscle is necessary.

    The Zimmer Biomet Reverse Shoulder is indicated for primary, fracture, or revision total shoulder replacement for the relief of pain and significant disability due to gross rotator cuff deficiency.

    The assembled humeral component may be used alone for hemiarthroplasty or combined with the glenoid component or reverse components for total shoulder arthroplasty (conventional or reverse applications). The humeral components may be used cemented or uncemented (biological fixation).

    The Titanium Humeral Head and Glenosphere components are indicated for patients with suspected cobalt alloy sensitivity. The wear properties of Titanium and Titanium alloys are inferior to that of cobalt alloy. A Titanium humeral head or Glenospheres not recommended for patients who lack suspected material sensitivity to cobalt alloy.

    Comprehensive Nano Stemless Shoulder System

    1. Primary total shoulder arthroplasty.
    2. Non-inflammatory degenerative joint disease including

    Comprehensive Nano Stemless Shoulder humeral components have a porous coated surface coating and are indicated for uncemented biological fixation applications.

    The Comprehensive Modular Hybrid Glenoid is intended to be implanted with bone cement. The porous titanium peg may be inserted without bone cement.

    Device Description

    The Identity Shoulder System is previously cleared (K213856/K240876) as a comprehensive collection of components designed with the intention of providing the modularity and adaptability necessary to facilitate individual anatomical adjustment and restoration of the glenohumeral joint during shoulder arthroplasty. The Identity Shoulder System is cleared for hemi-arthroplasty and conventional total shoulder replacement in both the anatomic and reverse configurations. The current submission is for the anatomic configuration.

    The subject Comprehensive Humeral Head Adapter (CHHA) is a line extension to the Identity Shoulder System (K213856) cleared for the hemi-arthroplasty configuration and anatomic Total Shoulder Configuration.

    The new CHHA (PN SAHHA002) allows additional compatibility with the previously cleared Identity Humeral Heads (K213856) and the Comprehensive humeral components, excluding fracture stems, as noted below:

    • Comprehensive Humeral Stems (K193038); and
    • Comprehensive Nano Stemless shoulder component (K182516).
    AI/ML Overview

    Based on the provided FDA 510(k) clearance letter for the "Identity Shoulder System" (K250848), here's an analysis of the acceptance criteria and the study that proves the device meets them:

    Crucial Observation: The provided document is a 510(k) clearance letter for a medical device that does not appear to be software or an AI/ML enabled device. It is for an orthopedic implant (shoulder system). Therefore, several of the requested points related to AI/ML (e.g., sample size for training set, number of experts for ground truth, MRMC studies, standalone algorithm performance) are not applicable to this type of traditional medical device submission.

    The "acceptance criteria" for this device are generally based on non-clinical performance testing to demonstrate the device's physical and mechanical properties meet established standards and are substantially equivalent to predicate devices. There are no "reported device performance" metrics in the sense of clinical performance (like sensitivity/specificity for AI, diagnostic accuracy, etc.) because it's a physical implant, not a diagnostic or AI-driven system.


    Acceptance Criteria and Study Details (Based on the provided document)

    Since the document provided is for a physical orthopedic implant, the "acceptance criteria" and "study" are interpreted in the context of demonstrating substantial equivalence for a traditional medical device, primarily through non-clinical performance testing.

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategorySpecific Test/EvaluationAcceptance Criteria (Implicit for Substantial Equivalence)Reported Device Performance (Summary from Document)
    Mechanical PerformanceFatigue VerificationDevice withstands specified cyclic loading without failure, demonstrating durability comparable to predicates.Non-clinical verification successfully performed.
    Fretting Corrosion VerificationDevice components resist fretting corrosion under specified conditions, comparable to predicates.Non-clinical verification successfully performed.
    Fixation Stability VerificationDevice maintains stable fixation under simulated physiological loads, comparable to predicates.Non-clinical verification successfully performed.
    Static Modular Junction Strength VerificationModular junctions maintain integrity and strength under static loads, comparable to predicates.Non-clinical verification successfully performed.
    CompatibilityROM VerificationDevice allows for intended range of motion when implanted, comparable to predicates.Non-clinical verification successfully performed.
    Imaging CompatibilityMRI VerificationDevice is compatible with MRI (e.g., minimal artifact, no excessive heating), comparable to predicates.Non-clinical verification successfully performed.
    Material EquivalenceMaterials compositionIdentical to legally marketed predicate devices."Identical to predicates"
    Design EquivalenceDesign FeaturesSimilar to legally marketed predicate devices, with any differences not raising new safety/effectiveness concerns."Similar to predicates"
    Packaging EquivalencePackagingIdentical to legally marketed predicate devices, ensuring sterility and protection."Identical to predicates"
    Sterilization EquivalenceSterilization MethodIdentical to legally marketed predicate devices, ensuring sterility."Identical to predicates"
    Intended Use EquivalenceIntended UseIdentical to legally marketed predicate devices."Identical to predicates"
    Indications for Use EquivalenceIndications for UseIdentical to legally marketed predicate devices."Identical to predicates"

    Note: For traditional orthopedic implants, specific numerical values for acceptance criteria and device performance (e.g., "Fatigue life > X cycles at Y load") are typically contained within the full 510(k) submission and are not usually detailed in the public clearance letter. The letter only states that these verifications were "successfully performed" and support the conclusion of substantial equivalence.


    AI/ML Specific Questions (Answered as "Not Applicable" for this device)

    Given that this is a 510(k) for a physical orthopedic implant and not an AI/ML device, the following points are not applicable (N/A):

    1. Sample sizes used for the test set and the data provenance: N/A. This device does not have a "test set" of patient data in the typical sense for AI/ML validation involving images or clinical parameters. Its evaluation involves mechanical testing of physical samples.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: N/A. Ground truth establishment by experts for clinical data is not relevant for this device.
    3. Adjudication method (e.g. 2+1, 3+1, none) for the test set: N/A. This applies to review of clinical data, not mechanical testing.
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: N/A. MRMC studies are for evaluating human reader performance, typically with diagnostic images, in conjunction with AI. This is not a diagnostic or AI-assisted device.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: N/A. This device is not an algorithm.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.): N/A. The "ground truth" for this device's performance is derived from standardized mechanical testing methods and compliance with material specifications.
    7. The sample size for the training set: N/A. This device does not use a "training set" as it's not an AI/ML model.
    8. How the ground truth for the training set was established: N/A.

    Summary of the Study:

    The "study" that proves the device meets the acceptance criteria is described as a series of non-clinical verifications. These tests are designed to objectively assess the physical and mechanical properties of the Comprehensive Humeral Head Adapter (CHHA) and its compatibility within the Identity Shoulder System, thereby demonstrating its substantial equivalence to previously cleared predicate devices.

    The specific non-clinical tests performed include:

    • Fatigue Verification: Assesses the device's ability to withstand repeated stress without failure, simulating long-term use.
    • Fretting Corrosion Verification: Evaluates the device's resistance to material degradation caused by small-amplitude oscillatory motion between contacting surfaces.
    • Fixation Stability Verification: Confirms the secure attachment and stability of components under load.
    • Static Modular Junction Strength Verification: Measures the strength of the connections between modular parts under static loading conditions.
    • ROM Verification: Ensures the device allows for the intended range of motion within the joint.
    • MRI Verification: Confirms the device's safety and compatibility when exposed to magnetic resonance imaging environments.

    The results of these tests, along with the asserted identicality of intended use, indications for use, materials, packaging, and sterilization, and similarity in design features, were deemed sufficient by the FDA to conclude that:

    • any differences do not raise different questions of safety and effectiveness; and
    • the proposed device is as safe and effective as the legally marketed predicate device.

    This conclusion of substantial equivalence is the basis for the 510(k) clearance for the Identity Shoulder System's new line extension, the Comprehensive Humeral Head Adapter.

    Ask a Question

    Ask a specific question about this device

    K Number
    K243509

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-05-12

    (181 days)

    Product Code
    Regulation Number
    888.3660
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    | KWT |
    | Catalyst CSR 3 Peg Glenoids | K173812 | 888.3650 | KWT |
    | Catalyst CSR Shoulder System |
    K181287 | 888.3650 | KWT |
    | Catalyst CSR Press-Fit Humeral Components | K182500 | 888.3650 | KWT |
    |
    Catalyst OrthoScience CSR Shoulder System | K191811 | 888.3650 | KWT |
    | Catalyst EA Convertible Stemmed
    | KWT |
    | Catalyst CSR 3 Peg Glenoids | K173812 | 888.3650 | KWT |
    | Catalyst CSR Shoulder System |
    K181287 | 888.3650 | KWT |
    | Catalyst CSR Press-Fit Humeral Components | K182500 | 888.3650 | KWT |
    |

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Archer^R PSI System is indicated as an orthopedic instrument to assist the physician in the intraoperative positioning of total shoulder replacement components and in guiding the drill and the cut of the bone.

    Archer^R PSI System must only be used conjointly with Archer™ CSR Total Shoulder (K152825, K173812, K181287, K182500, K191811), Catalyst EA Convertible Stemmed Shoulder (K222317) and Archer™ R1 Reverse (K202611, K211991, K213349, K223655, K232583) components in the context of primary total shoulder replacement and following a delto-pectoral approach only. Archer^R PSI System is manufactured from a pre-operative planning validated by the surgeon in the 'Archer™ 3D Targeting' platform (K213779). Archer^R PSI System is indicated for patient population fulfilling the Archer™ CSR Total Shoulder, Catalyst EA Convertible Stemmed Shoulder and Archer™ R1 Reverse indications and for which CT images are available with identifiable placement anatomical landmarks and compliant with imaging protocol provided by Archer 3D Targeting.

    The device is intended for single use only.

    The device is intended for adult patients.

    The device has to be used by a physician trained in the performance of surgery.

    Device Description

    The "Archer PSI System" device is a patient-matched additively manufactured single use surgical instrument (PSI). Archer PSI System is an instrument set containing a glenoid guide and its bone model and/or a humeral guide and its bone model. This patient-specific medical device is designed to fit the patient's anatomy to transfer a patient-specific pre-operative plan to the operating room. It is intended for surgical interventions in orthopaedic procedures for total shoulder arthroplasty.

    The Archer PSI system instruments are designed from a draft treatment plan available via the Archer™ 3D Targeting' platform. Based on computed tomography (CT) of the shoulder anatomy, 3D CAD models of the bones and positioning and sizing of the glenoid and humeral components are submitted for evaluation to the surgeon. Upon the surgeon's approval, the guides and bone models are designed based on the validated planning and are manufactured using additive manufacturing.

    AI/ML Overview

    The provided FDA 510(k) summary for the "Archer PSI System" does not contain the detailed acceptance criteria or the specific study that directly proves the device meets those criteria in a quantitative manner as typically expected for medical device performance studies involving sensitivity, specificity, accuracy, etc. However, it does outline the types of non-clinical and cadaveric testing performed to demonstrate substantial equivalence to a predicate device.

    Here's an attempt to structure the information based on the request, extracting what is available and noting what is not:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not overtly state quantitative "acceptance criteria" (e.g., "accuracy must be > 95%") nor does it provide "reported device performance" in terms of explicit metrics like sensitivity, specificity, or error rates. Instead, the "performance" is described in terms of demonstrating "substantial equivalence" through various engineering and cadaveric tests.

    A more accurate representation, based on the provided text, would be:

    Acceptance Criteria CategoryDescription (from document)Reported Device Performance (from document)
    Mechanical IntegrityDemonstrate mechanical integrity post-processing.Testing was conducted.
    Debris GenerationAssess debris generation.Testing was conducted.
    Intra-Designer VariabilityAssess variability within a single designer's output.Testing was conducted.
    Inter-Designer VariabilityAssess variability between different designers' outputs.Testing was conducted.
    BiocompatibilityEnsure material biocompatibility.Assessment conducted.
    Cleaning & SterilizationValidate cleaning and sterilization processes.Validations conducted.
    Manufacturing CleaningValidate manufacturing cleaning processes.Validation conducted.
    Packaging & Shelf-lifeValidate packaging integrity and shelf-life.Validation conducted.
    Functional EquivalenceDemonstrate functional equivalence to manual techniques for positioning and guiding drill/cut.Cadaveric testing executed to demonstrate substantial equivalence between two techniques (manual and PSI, for both anatomic and for reverse techniques).
    Pre-operative PlanningManufactured from a pre-operative planning validated by the surgeon in the 'Archer™ 3D Targeting' platform (K213779).The device design is based on surgeon-validated plans within the Archer™ 3D Targeting platform. This implies an acceptance of the planning accuracy by the surgeon.

    2. Sample Size for the Test Set and Data Provenance

    • Sample Size for Cadaveric Testing: The document states that "Cadaveric testing was executed" but does not specify the sample size (number of cadavers or procedures) used for this testing.
    • Data Provenance: The cadaveric testing is implied to be prospective in nature, as it was "executed to demonstrate the substantial equivalence." There is no information provided regarding the country of origin of the cadaveric data.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    • Number of Experts: The document states that "a pre-operative planning validated by the surgeon" is part of the process. For the cadaveric testing, it does not explicitly state the number of experts (e.g., surgeons) involved in establishing the "ground truth" or assessing the "substantial equivalence."
    • Qualifications of Experts: The document mentions that the device is to be used by a "physician trained in the performance of surgery." For the validation of the pre-operative plan, the expert is identified as "the surgeon." While this indicates a medical professional, specific qualifications (e.g., years of experience, subspecialty) are not provided.

    4. Adjudication Method for the Test Set

    The document does not specify an adjudication method (e.g., 2+1, 3+1, none) for the cadaveric testing or any other performance evaluation. The "validation by the surgeon" for the pre-operative plan suggests a form of single-expert consensus at the planning stage, but not for the overall performance assessment.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • Was an MRMC study done? No.
    • Effect Size: As no MRMC study was performed, no effect size of human readers improving with AI vs. without AI assistance is reported. The Archer PSI System is a patient-specific instrument, not an AI diagnostic or assistive tool in the MRMC sense. The comparison was between manual surgical techniques and PSI-assisted techniques in cadavers.

    6. Standalone (Algorithm Only) Performance Study

    • Was a standalone study done? Not explicitly in terms of an "algorithm only" performance study. The device itself is a physical, patient-specific instrument derived from a digital plan. The document describes "Cadaveric testing" which evaluates the combined PSI system (planning software output + physical guide) in a simulated surgical environment, not just the planning algorithm in isolation from its physical manifestation or use.
    • The "Intra- and Inter-Designer Variability testing" and "Mechanical Integrity" tests are standalone evaluations of aspects of the device's design and manufacturing, but not of the surgical guidance algorithm's performance on its own.

    7. Type of Ground Truth Used

    • For Pre-operative Planning: The ground truth for the design of the PSI System is based on a "pre-operative planning validated by the surgeon" using CT images and anatomical landmarks. This can be considered a form of expert consensus/validation on the desired surgical outcome/instrument design.
    • For Cadaveric Testing: The "ground truth" for the cadaveric study would be the actual anatomical targets and the achieved drill/cut placements, compared to the planned placements and traditional manual techniques. While experts (surgeons) would perform and assess these, the ultimate "truth" is the physical reality within the cadaver. The document implies comparison to "manual techniques" as a reference.

    8. Sample Size for the Training Set

    The document does not provide any information regarding a "training set sample size." The Archer PSI System is described as being "designed from a draft treatment plan" and "manufactured from a pre-operative planning validated by the surgeon." This suggests a patient-specific design process rather than a machine learning model trained on a large dataset. The underlying "Archer™ 3D Targeting' platform (K213779)" (a separate cleared device) would be the system performing the planning, and its own 510(k) might contain training data details if it uses AI/ML. However, for the Archer PSI System itself, no training set information is present.

    9. How Ground Truth for the Training Set Was Established

    As no training set is mentioned for the Archer PSI System in this document, no information is provided on how its ground truth would have been established.

    Ask a Question

    Ask a specific question about this device

    K Number
    K241944

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-03-10

    (251 days)

    Product Code
    Regulation Number
    888.3650
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    20001

    Re: K241944

    Trade/Device Name: AGILON® XO Shoulder Replacement System Regulation Number: 21 CFR 888.3650
    |
    | Classifications: | 21 CFR 888.3650

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The AGILON® XO Shoulder Replacement System is indicated for use for total or hemi shoulder replacement in cases of:

    • · Non- inflammatory deqenerative joint disease including osteoarthritis and avascular necrosis,
    • · Post-traumatic osteoarthritis.
    • · Fractures,
    • · Rheumatoid arthritis.

    The main indications for the implantation of an AGILON® hemi shoulder prosthesis are:

    • · Multi-fragmental comminuted fractures of the humeral head,
    • · 3- and 4-Fragment-fractures of the proximal humerus,
    • · Head-splitting fractures,
    • · Dislocated head-splitting fractures,
    • · Humeral head depression with more than 40% of joint surface depressed,
    • · Interlocking chronic dislocation with deep HILL-SACHS lesion,
    • · Fracture instability following internal fixation attempt in 3-fragment fractures (secondary dislocation, material loosening),
    • · Posttraumatic humeral head necrosis,
    • · Omarthrosis.

    AGILON® CTA heads are destined for treatment of stable types of rotator cuff tear arthropathy. In order to achieve satisfactory results with the CTA heads the fornix humeri and the subscapularis tendon must be intact. A CTA cap is intended for the use as a hemi-arthroplasty, to treat a patient after an inverse shoulder has failed. It is not combined with a glenoid implant. It can be used in primary and revision cases.

    The main indications for the implantation of an AGILON® inverse (reverse) shoulder prosthesis are:

    • · Rotator cuff tear arthropathy,
    • · Chronic trauma shoulder,
    • · Decentering of the humeral head after implantation of a humeral head prosthesis.

    Please note, that the patient's joint must be anatomically and structurally suited to receive the selected implant(s), and a functional deltoid muscle is necessary.

    In case of revision surgery the available bone stock has to be evaluated to allow for implantation of well-fixed stems. Conversion of the system can be performed in revision cases as follows:

    • · From Hemi Shoulder Arthroplasty to Anatomic Total Shoulder Arthroplasty
    • · From Hemi Shoulder Arthroplasty to Hemi CTA Shoulder Arthroplasty
    • · From Hemi Shoulder Arthroplasty to Inverse (Reverse) Total Shoulder Arthroplasty
    • · From Inverse (Reverse) Total Shoulder Arthroplasty to Hemi Shoulder Arthroplasty as salvage procedure
    • · From Inverse (Reverse) Total Shoulder Arthroplasty to Hemi CTA Shoulder Arthroplasty as salvage procedure
    • From Anatomic Total Shoulder Arthroplasty to Inverse (Reverse) Total Shoulder Arthroplasty
    • · From Anatomic Total Shoulder Arthroplasty to Hemi CTA Shoulder Arthroplasty
      The device is intended for adults.

    The AGILON® XO Shoulder Replacement System Titanium alloy stems are intended for cementless fixation.

    The PE-glenoids of the AGILON® XO Shoulder Replacement System are intended for cemented fixation. The qlenoid cementless is intended for cementless use with the addition of screws for fixation.

    Device Description

    The AGILON® XO Shoulder Replacement System is a modular shoulder replacement system offering various components that can be combined to replace the shoulder joint with options depending upon the size and anatomical needs of each patient. The subject submission is for new cancellous screws for use in a total reverse shoulder replacement with the previously cleared K231657 components:

    • Humeral Head Components ●
    • Glenoid and Glenosphere Components ●
    • Humeral Stems and Stem Extension Pieces
    • Metaphyseal Components ●
    • Fixation and Cancellous Screws ●

    The subject line extension components are intended for use with previously cleared AGILON XO Shoulder System instruments. There are no changes to packaging, sterility, shelf life, or materials subject to this submission.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the AGILON® XO Shoulder Replacement System, focusing on new cancellous screws. However, it does not include detailed acceptance criteria or a comprehensive study report with the specific information requested in your prompt regarding AI/algorithm performance.

    The document primarily focuses on demonstrating substantial equivalence to a predicate device through engineering analysis and limited performance testing of the new cancellous screws. Therefore, I cannot provide all the requested information.

    Here's what I can extract and infer from the provided text, along with what is explicitly not available:


    1. A table of acceptance criteria and the reported device performance

    Acceptance Criteria (for cancellous screws)Reported Device Performance (type of testing)
    Sufficient performance for intended use (specific numeric criteria not provided)- Torsional Properties (ASTM F543)- Driving Torque (ASTM F543)- Axial Pull-out Strength (ASTM F543)
    Predetermined acceptance criteria met (specific numeric criteria not provided)Testing demonstrated sufficient performance and met predetermined acceptance criteria.
    Biocompatibility (per ISO 10993-1)Evaluation completed per ISO 10993-1.
    Cleaning, sterilization, packaging, shelf-life, and endotoxin standards metLeveraged from the predicate AGILON® XO Shoulder Replacement System (K231657).

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample Size: Not specified for the cancellous screw testing (Torsional Properties, Driving Torque, Axial Pull-out Strength).
    • Data Provenance: Not specified. The manufacturer is implantcast, GmbH, located in Buxtehude, Germany, but the location where testing was performed is not mentioned. The study is part of a 510(k) submission, generally involving laboratory testing rather than clinical data provenance in this context.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    Not applicable. This device is a mechanical shoulder replacement system, and the testing described is mechanical performance (e.g., strength, torque) and biocompatibility, not an AI or diagnostic device that requires expert ground truth for interpretation of medical images or conditions.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable. This device is a mechanical shoulder replacement system, not a diagnostic or AI device that requires adjudication of expert interpretations.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is a medical device (shoulder replacement system), not an AI-assisted diagnostic tool. No AI component or human reader study is mentioned.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is a medical device (shoulder replacement system), not a standalone algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    For the mechanical testing of the cancellous screws, the "ground truth" is established by adherence to recognized ASTM standards (ASTM F543) and engineering principles. For biocompatibility, the ground truth is adherence to ISO 10993-1. This is not related to clinical outcomes or expert consensus on pathologies for AI model training.

    8. The sample size for the training set

    Not applicable. This device is a mechanical shoulder replacement system, not an AI/machine learning device that requires a training set.

    9. How the ground truth for the training set was established

    Not applicable. This device is a mechanical shoulder replacement system, not an AI/machine learning device.


    Summary of what is present:

    The document describes the submission of a medical device (AGILON® XO Shoulder Replacement System) for regulatory clearance. The specific focus of this submission (K241944) is the addition of new cancellous screws to an existing system. The performance testing for these screws involved:

    • Engineering analysis.
    • Characterization per ASTM F543 for torsional properties, driving torque, and axial pull-out strength.
    • Biocompatibility evaluation per ISO 10993-1.
    • Leveraging existing data for cleaning, sterilization, packaging, shelf-life, and endotoxin from the predicate device (K231657).

    The conclusion is that the testing demonstrated "sufficient performance for the intended use" and "met the predetermined acceptance criteria." However, the specific quantitative values for these criteria and the test results are not detailed in the provided text.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 17