Search Filters

Search Results

Found 59 results

510(k) Data Aggregation

    K Number
    K254045

    Validate with FDA (Live)

    Date Cleared
    2026-03-16

    (89 days)

    Product Code
    Regulation Number
    888.3075
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Cervical Screw System; CarboClear® Hybrid Posterior Cervical Screw System
    Regulation Number: 21 CFR 888.3075
    **
    Posterior, Cervical Spine Fixation

    Regulation Number and Device Class
    Class II; 21 CFR §888.3075
    Name**

    Posterior, Cervical Spine Fixation

    Regulation Number and Device Class

    Class II; 21 CFR §888.3075

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The CarboClear® Posterior Cervical Screw System / CarboClear® Hybrid Posterior Cervical Screw System is intended to restore the integrity of the spinal column even in the absence of fusion for a limited time period in patients with advanced stage tumors involving the cervical spine in whom life expectancy is of insufficient duration to permit achievement of fusion.

    The CarboClear® Posterior Cervical Screw System / CarboClear® Hybrid Posterior Cervical Screw System is intended to provide immobilization and stabilization of spinal segments with anterior interbody support implanted at the same spinal level/s as an adjunct to fusion for the following acute and chronic instabilities of the cervical spine and the upper thoracic spine (T1 to T3):

    • Traumatic spinal fractures and/or dislocations
    • Instability and deformity
    • Failed previous fusions (e.g., pseudarthrosis)
    • Degenerative disease, including intractable radiculopathy and/or myelopathy
    • Neck and/or arm pain of discogenic origin as confirmed by radiographic studies
    • Degenerative disease of the facets with instability
    • Patients with spinal infection (e.g., spondylodiscitis, osteomyelitis) and spinal instability due to infection, surgical debridement, or decompression

    The CarboClear® Posterior Cervical Screw System / CarboClear® Hybrid Posterior Cervical Screw System is intended to be used with anterior interbody support implanted at the same spinal level/s with autogenous and /or allogenic bone graft comprised of cancellous and/or corticocancellous bone graft.

    Device Description

    CarboClear® Posterior Cervical Screw System ("CarboClear® System") and CarboClear® Hybrid Posterior Cervical Screw System ("CarboClear® Hybrid System") are composed of implants in various dimensions, used to build a spinal construct; and of a set of instruments, intended to assist in the insertion and placement of the implants.

    The screws incorporated into the systems are made of carbon fiber-reinforced polyetheretherketone (CFR-PEEK), with the CarboClear® Hybrid screws incorporating titanium alloy tulip. The screws threaded portion, and spherical head are encased within a thin titanium shell, and they may include a tantalum marker. The CarboClear® posterior cervical screws are used with CFR-PEEK set screw, and the CarboClear® Hybrid posterior cervical screws are used with a titanium alloy set screw. All screws are used with CarboClear® CFR-PEEK rods. CarboClear® titanium alloy rods are also offered.

    The implants are supplied sterile, and are intended for single use.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K254165

    Validate with FDA (Live)

    Date Cleared
    2026-01-21

    (30 days)

    Product Code
    Regulation Number
    888.3075
    Age Range
    18 - 120
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Tennessee 38132

    Re: K254165
    Trade/Device Name: Infinity™ OCT System
    Regulation Number: 21 CFR 888.3075
    Classification:**
    Implants: Class II
    Instruments: Class II

    Product Codes:
    Implants: NKG (888.3075

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Infinity™ OCT System is intended to provide immobilization and stabilization of spinal segments as an adjunct to fusion for the following acute and chronic instabilities of the craniocervical junction, the cervical spine (C1 to C7), and the thoracic spine from T1-T3. These devices are to be used with autograft and/or allograft.

    • Traumatic spinal fractures and/or traumatic dislocations.
    • Instability or deformity.
    • Failed previous fusions (e.g. pseudarthrosis).
    • Tumors involving the cervical spine.
    • Degenerative disease, including intractable radiculopathy and/or myelopathy, neck and/or arm pain of discogenic origin as confirmed by radiographic studies, and degenerative disease of the facets with instability.

    The Infinity™ OCT System is also intended to restore the integrity of the spinal column even in the absence of fusion for a limited time in patients with advanced stage tumors involving the cervical spine in whom life expectancy is of insufficient duration to permit achievement of fusion.

    The Infinity™ OCT System may be used with PASS OCT Patient Specific UNiD OCT rods. In order to achieve additional levels of fixation, the Infinity™ OCT System may be connected to the CD Horizon™ Spinal System and Vertex™ Reconstruction System rods with the Infinity™ OCT System rod connectors. Transition rods with differing diameters may also be used to connect the Infinity™ OCT System to the CD Horizon™ Spinal System. Refer to the CD Horizon™ Spinal System package insert, Vertex™ Reconstruction System, and PASS OCT Spinal System package inserts for a list of the indications of use.

    Note: The 3.0mm multi axial screw (MAS) requires the use of MAS CROSSLINK™ at each level in which the 3.0mm screw is intended to be used.

    The lateral offset connectors and MAS extension connectors are intended to be used with 3.5mm and larger diameter multi axial screws. The lateral offset connectors and MAS extension connectors are not intended to be used with 3.0mm screws.

    Note: Segmental fixation is recommended for these constructs.

    Medtronic Navigated Reusable Instruments for use with StealthStation™ and IPC™ POWEREASE™ Systems

    Medtronic Navigated Reusable Instruments are intended to be used during the preparation and placement of Medtronic screws during spinal surgery to assist in precisely locating anatomical structures in either open, or minimally invasive, procedures. Medtronic Navigated Reusable Instruments are specifically designed for use with the StealthStation™ System, which is indicated for any medical condition in which the use of stereotactic surgery may be appropriate, and where reference to a rigid anatomical structure, such as a skull, a long bone, or vertebra can be identified relative to a CT or MR-based model, fluoroscopy images, or digitized landmarks of the anatomy.

    Stealth™ Spine Clamps

    When used with Medtronic computer assisted surgery systems, defined as including the Stealth™ System, the following indications of use are applicable:

    • The spine referencing devices are intended to provide rigid fixation between patient and patient reference frame for the duration of the surgery. The devices are intended to be reusable.
    • The navigated instruments are specifically designed for use with Medtronic computer assisted surgery systems, which are indicated for any medical condition in which the use of stereotactic surgery may be appropriate or vertebra can be identified relative to a CT or MR based model, fluoroscopy images, or digitized landmarks of the anatomy.
    • The Stealth™ spine clamps are indicated for skeletally mature patients.
    Device Description

    Infinity™ OCT System

    The Infinity™ OCT System is a posterior occipitocervical-upper thoracic system, which consists of a variety of shapes and sizes of plates, rods, hooks, screws, multi-axial screws, and connecting components, which can be rigidly locked to the rod in a variety of configurations, with each construct being tailor-made for the individual case.

    The Infinity™ OCT System is fabricated from medical grade titanium alloy and medical grade cobalt chromium. Medical grade titanium alloy and medical grade cobalt chromium may be used together. Never use titanium alloy and/or cobalt chromium with stainless steel in the same construct. No warranties, expressed or implied, are made. Implied warranties of merchantability and fitness for a particular purpose or use are specifically excluded.

    To achieve best results, do not use any of the Infinity™ OCT System implant components with components from any other system or manufacturer unless specifically labeled to do so in this or another Medtronic document. As with all orthopedic and neurosurgical implants, Infinity™ OCT System components should never be reused under any circumstances.

    Medtronic Navigated Referencing Devices

    Medtronic navigated referencing devices provide rigid fixation to patient anatomy and enables the assembly of a patient reference frame. Various types of instruments are available including spine referencing clamps and associated connections to maintain compatibility with current spine reference frames.

    Medtronic navigated referencing devices are compatible with various Medtronic spinal implant systems including Medtronic computer assisted surgery systems, including, but not not limited to, StealthStation™ and/or Mazor™ systems, and Medtronic navigation reusable instruments. These instruments are also compatible with Medtronic's IPC™ Powerease™ System when connected to the Powerease™ Driver.

    Medtronic navigated referencing devices are supplied as non-sterile reusable instruments. All devices should be cleaned and sterilized before use.

    Medtronic navigated referencing devices are manufactured from a variety of materials commonly used in orthopedic and neurological procedures, which meet applicable national and/or international standards. These instruments may be shipped in accessories. Accessories include cases, trays, lids, caddies, and modules fabricated from a variety of materials, which meet national and international standards, and are commonly used to enclose, protect, and organize Medtronic orthopedic and neurological reusable instruments.

    Medtronic Reusable Instruments and Accessories

    Reusable instruments are manufactured from a variety of materials commonly used in orthopedic and neurological procedures, which meet applicable national and/or international standards. These instruments may be shipped in Medtronic Transportation/ Sterilization Cassettes. The Medtronic Transportation/Sterilization Cassettes are designed to be used in conjunction with a legally marketed, validated, and FDA-cleared sterilization wrap to allow steam sterilization of non-sterile devices.

    Medtronic Transportation/Sterilization Cassettes include cases, trays, lids, caddies, modules, or brackets fabricated from a variety of materials, which meet national and international standards, and are commonly used to enclose, protect, and organize Medtronic orthopedic or neurological non-sterile devices. The Medtronic Transportation/Sterilization Cassettes are not intended on their own to maintain sterility; it is intended to be used in conjunction with a legally marketed, validated, FDA-cleared sterilization wrap. The Medtronic Transportation Sterilization Cassettes are intended for transport of non-sterile loads.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252327

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-11-12

    (110 days)

    Product Code
    Regulation Number
    888.3075
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Device Name:** CMORE® CT System; CMORE® CT System Navigated Instruments
    Regulation Number: 21 CFR 888.3075
    Washington, DC 20001
    Office: 202.552.5800

    Date Prepared: 11/10/2025

    Classifications: 21 CFR §888.3075
    Washington, DC 20001
    Office: 202.552.5800

    Date Prepared: 11/10/2025

    Classifications: 21 CFR §888.3075

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The CMORE® CT System is intended to restore the integrity of the spinal column even in the absence of fusion for a limited time period in patients with advanced stage tumors involving the cervical spine in whom life expectancy is of insufficient duration to permit achievement of fusion.

    In patients requiring adjuvant radiotherapy following spinal stabilization, metal markers at the screw tips can be used as fiducial markers in radiotherapy treatments (e.g., SBRT, proton therapy).

    The CMORE® CT System is intended to provide immobilization and stabilization of spinal segments with anterior interbody support implanted at the same spinal level/s as an adjunct to fusion for the following acute and chronic instabilities of the cervical spine (C1 to C7) and the upper thoracic spine (T1 to T3):

    • Traumatic spinal fractures and/or traumatic dislocations
    • Instability or deformity
    • Failed previous fusions (e.g. pseudarthrosis)
    • Degenerative disease, including intractable radiculopathy and/or myelopathy
    • Neck and/or arm pain of discogenic origin as confirmed by radiographic studies
    • Degenerative disease of the facets with instability
    • Patients with spinal infection (e.g., spondylodiscitis, osteomyelitis) and spinal instability due to infection, surgical debridement, or decompression.

    The CMORE® CT System is intended to be used with anterior interbody support implanted at the same spinal level/s with autogenous and/or allogenic bone graft comprised of cancellous and/or corticocancellous bone graft.

    The CMORE® CT System may be connected to the VADER® Pedicle System using connectors.

    CMORE® CT System Navigated Instruments
    CMORE® CT System Navigated Instruments are intended to be used during the preparation and placement of the CMORE® CT System during spinal surgery to assist the surgeon in precisely locating anatomical structures in open procedures. These instruments are designed for use with the Medtronic StealthStation® and Brainlab Navigation Systems which are indicated for any medical condition in which the use of stereotactic surgery may by appropriate, and where reference to a rigid anatomical structure, such as a vertebra, can be identified relative to a CT- or MR- based model, fluoroscopy images, or digitized landmarks of anatomy.

    Device Description

    CMORE® CT System
    The CMORE® CT System is a posterior cervical fixation system intended to provide structural stability and mechanical support to the cervical and upper thoracic spine. The CMORE® CT System is manufactured from Carbon/PEEK using a proprietary manufacturing process and is comprised of screws, rods, nut screws, and connectors as well as corresponding instruments.

    CMORE® CT System System Navigated Instruments
    The CMORE® CT System Navigated Instruments are reusable instruments used for the preparation and placement of FDA-cleared spinal bone screws during spinal surgery to assist the surgeon in precisely locating anatomical structures. These instruments are designed to be used with the Medtronic StealthStation® and Brainlab Navigation Systems. The instruments include awls, drills, probes, taps, drivers, and adapters.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K253129

    Validate with FDA (Live)

    Date Cleared
    2025-10-24

    (29 days)

    Product Code
    Regulation Number
    888.3075
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    38132

    Re: K253129
    Trade/Device Name: Infinity™ OCT System
    Regulation Number: 21 CFR 888.3075
    Classification: Implants: Class II, Instruments: Class II
    Product Codes: Implants: NKG (888.3075

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Infinity™ OCT System

    The Infinity™ OCT System is intended to provide immobilization and stabilization of spinal segments as an adjunct to fusion for the following acute and chronic instabilities of the craniocervical junction, the cervical spine (C1 to C7), and the thoracic spine from T1-T3:

    • Traumatic spinal fractures and/or traumatic dislocations.
    • Instability or deformity.
    • Failed previous fusions (e.g. pseudarthrosis).
    • Tumors involving the cervical spine.
    • Degenerative disease, including intractable radiculopathy and/or myelopathy, neck and/or arm pain of discogenic origin as confirmed by radiographic studies, and degenerative disease of the facets with instability.

    The Infinity™ OCT System is also intended to restore the integrity of the spinal column even in the absence of fusion for a limited time in patients with advanced stage tumors involving the cervical spine in whom life expectancy is of insufficient duration to permit achievement of fusion.

    The Infinity™ OCT System may be used with PASS OCT Patient Specific UNiD OCT rods. In order to achieve additional levels of fixation, the Infinity™ OCT System may be connected to the CD Horizon™ Spinal System and Vertex™ Reconstruction System rods with the Infinity™ OCT System rod connectors. Transition rods with differing diameters may also be used to connect the Infinity™ OCT System to the CD Horizon™ Spinal System. Refer to the CD Horizon™ Spinal System package insert, Vertex™ Reconstruction System and PASS OCT Spinal System package insert for a list of the indications of use.

    Note: The 3.0mm multi axial screw (MAS) requires the use of MAS CROSSLINK™ at each level in which the 3.0mm screw is intended to be used.

    The lateral offset connectors and MAS extension connectors are intended to be used with 3.5mm and larger diameter multi axial screws. The lateral offset connectors and MAS extension connectors are not intended to be used with 3.0mm screws.

    Note: Segmental fixation is recommended for these constructs.

    Medtronic Navigated Reusable Instruments for use with StealthStation™ and IPC™ POWEREASE™ Systems

    Medtronic Navigated Reusable Instruments are intended to be used during the preparation and placement of Medtronic screws during spinal surgery to assist in precisely locating anatomical structures in either open, or minimally invasive, procedures. Medtronic Navigated Reusable Instruments are specifically designed for use with the StealthStation™ System, which is indicated for any medical condition in which the use of stereotactic surgery may be appropriate, and where reference to a rigid anatomical structure, such as a skull, a long bone, or vertebra can be identified relative to a CT or MR-based model, fluoroscopy images, or digitized landmarks of the anatomy.

    Device Description

    Infinity™ OCT System

    The Infinity™ OCT System is a posterior occipitocervical-upper thoracic system, which consists of a variety of shapes and sizes of plates, rods, hooks, screws, multi-axial screws, and connecting components, which can be rigidly locked to the rod in a variety of configurations, with each construct being tailor-made for the individual case.

    The Infinity™ OCT System is fabricated from medical grade titanium alloy and medical grade cobalt chromium.

    Medtronic Navigated Reusable Instruments for use with StealthStation™ and IPC™ POWEREASE™ Systems

    Medtronic Navigated Reusable Instruments are spine preparation instruments manufactured from high grade stainless steel. These instruments are specifically designed for use in procedures where the use of stereotactic surgery may be appropriate. Placing Medtronic single-use sterile spheres on each of the NavLock™ Tracker passive stems allows a Medtronic computer assisted surgery system such as the StealthStation™ Image Guidance System to track the instruments in the surgical field. Medtronic Navigated Reusable Instruments are compatible with various Medtronic spinal implant systems. These instruments are also compatible with Medtronic's IPC™ POWEREASE™ System when connected to the POWEREASE™ Driver.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251725

    Validate with FDA (Live)

    Date Cleared
    2025-06-25

    (20 days)

    Product Code
    Regulation Number
    888.3075
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    South Korea

    Re: K251725
    Trade/Device Name: ANAX™ OCT Spinal System
    Regulation Number: 21 CFR 888.3075
    Classification Name:** Spinal Interlaminal Fixation Orthosis
    Classification: Class II, 21 CFR 888.3075

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    ANAX™ OCT Spinal System is intended to provide immobilization and stabilization of spinal segments as an adjunct to fusion for the following acute and chronic instabilities of the craniocervical junction, the cervical spine (C1 to C7) and the thoracic spine from T1-T3: traumatic spinal fractures and/or traumatic dislocations; instability or deformity; failed previous fusions (e.g., pseudarthrosis); tumors involving the cervical spine; and degenerative disease, including intractable radiculopathy and/or myelopathy, neck and/or arm pain of discogenic origin as confirmed by radiographic studies, and degenerative disease of the facets with instability. ANAX™ OCT Spinal System is also intended to restore the integrity of the spinal column even in the absence of fusion for a limited time period in patients with advanced stage tumors involving the cervical spine in whom life expectancy is of insufficient duration to permit achievement of fusion.

    In order to achieve additional levels of fixation, ANAX™ OCT Spinal System may be connected to Perfix™ Spinal System and ANAX™ 5.5 Spinal System rods with the rod connectors. Transition rods with differing diameters may also be used to connect ANAX™ OCT Spinal System to Perfix™ Spinal System and ANAX™ 5.5 Spinal System.

    Device Description

    The ANAX™ OCT Spinal System is for fixation the cervicocranium (Occiput/C2), the true subaxial region (C3/C6), and the cervicothoracic junction (C7 to T2) by one system. The ANAX™ OCT Spinal System consists of polyaxial screws, polyaxial shank screws, hooks, rods, set screws, transverse (cross) links and occipital plate. Connectors are also provided for surgical convenience. The ANAX™ OCT Spinal System allows surgeons to build a spinal implant construct to stabilize and promote spinal fusion. The single-use ANAX™ OCT Spinal System components are supplied as non-sterile and are fabricated from medical grade titanium alloy (ASTM F136) and medical grade cobalt-chromium-molybdenum alloy (ASTM F1537). All polyaxial screws have self-tapping functions in the ANAX™ OCT Spinal System.

    Specialized instruments made from surgical instrument grade stainless steel are available for the application and removal of the ANAX™ OCT Spinal System implants.

    AI/ML Overview

    The provided FDA 510(k) Clearance Letter for the ANAX™ OCT Spinal System does not describe acceptance criteria or a study that proves the device meets specific acceptance criteria based on performance metrics such as sensitivity, specificity, or accuracy.

    Instead, this document focuses on demonstrating substantial equivalence to predicate devices. This is a common pathway for medical device clearance, where the new device is shown to be as safe and effective as a legally marketed device that does not require Pre-Market Approval (PMA).

    Here's an analysis based on the information provided, highlighting why certain questions cannot be answered from this document:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria (Not explicitly stated as such, but inferred from testing)Reported Device Performance
    Mechanical Integrity: Demonstrated through comprehensive mechanical testing (e.g., ASTM F1717, F1798) to ensure safety and effectiveness.Comparable/Superior Material Performance: Cobalt-chromium-molybdenum (CoCr) rods exhibit higher tensile and yield strength compared to titanium (Ti) rods. All failure modes occurred at the screw-housing interface, not the rod itself.
    Safety and Effectiveness: No new questions of safety or effectiveness introduced by the modification (addition of CoCr rods).Comparative material analysis and existing mechanical test data confirm equivalent or superior performance, indicating no new safety or effectiveness concerns.
    Design, Functions, Intended Use Equivalence: To predicate devices.The modified device maintains identical indications for use, equivalent overall construct design, dimensions, and components (with rod material being the only modification).

    Explanation: The "acceptance criteria" here are implicitly related to demonstrating that the new CoCr rods perform at least as well as, or better than, the existing titanium rods in terms of mechanical properties and do not alter the overall system's safety or intended function. The FDA's acceptance of the 510(k) implies that these criteria were met.


    Regarding the specific study details for AI/software-based devices, the following cannot be answered from this document because the ANAX™ OCT Spinal System is a physical implantable medical device, not an AI or software device.

    2. Sample size used for the test set and the data provenance: Not applicable. The "test set" here refers to physical components tested.
    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable. Ground truth for physical components is typically derived from engineering specifications and material science, not expert consensus in the diagnostic sense.
    4. Adjudication method for the test set: Not applicable.
    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable.
    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not applicable.
    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc): For a physical device, "ground truth" relates to material properties (e.g., tensile strength, yield strength), dimensional accuracy, and mechanical performance under simulated physiological loads, established by engineering standards (e.g., ASTM F136, F1537, F1717, F1798).
    8. The sample size for the training set: Not applicable. This is not an AI/ML device.
    9. How the ground truth for the training set was established: Not applicable.


    Summary of Relevant Information from the Document:

    • Device Type: Physical implantable spinal fixation system (ANAX™ OCT Spinal System).
    • Modification: Addition of cobalt-chromium-molybdenum (CoCr) rods.
    • Mechanism of Proof: Substantial equivalence to predicate devices.
    • Key Evidence for Substantial Equivalence:
      • Indications for Use: Identical to predicate devices.
      • Design & Components: Equivalent overall construct, dimensions, and components, with the only change being rod material.
      • Material Properties: CoCr rods demonstrate higher tensile and yield strength than the previously cleared titanium (Ti) rods.
      • Manufacturing: CoCr rods are manufactured and processed using the same methods and surface treatments as the Ti rods.
      • Performance Testing: Comprehensive mechanical testing (e.g., ASTM F1717, F1798) was conducted, including a worst-case configuration.
      • Failure Analysis: All observed failure modes occurred at the screw-housing interface, not within the rod itself, suggesting the rods are sufficiently strong.
    • Conclusion of Study: The mechanical integrity of the CoCr rods was confirmed, and the comparative material analysis showed comparable or superior performance, leading to the conclusion that the addition of CoCr rods does not raise new questions of safety or effectiveness.
    Ask a Question

    Ask a specific question about this device

    K Number
    K250866

    Validate with FDA (Live)

    Date Cleared
    2025-05-20

    (57 days)

    Product Code
    Regulation Number
    888.3075
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Re: K250866*
    Trade/Device Name: Sovereign Posterior Cervical System
    Regulation Number: 21 CFR 888.3075
    cervical screw system |
    | Classification Name | Posterior Cervical Screw System |
    | Regulation Number | 888.3075

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Sovereign Posterior Cervical System is intended to provide immobilization and stabilization of spinal segments as an adjunct to fusion for the following acute and chronic instabilities of the cervical spine (C1 to C7) and the thoracic spine (T1-T3): traumatic spinal fractures and/or traumatic dislocations; instability or deformity; failed previous fusions (e.g. pseudoarthrosis); tumors involving the cervical/thoracic spine; and degenerative disease, including intractable radiculopathy and/or myelopathy, neck and/or arm pain of discogenic origin as confirmed by radiographic studies, and degenerative disease of the facets with instability.

    The Sovereign Posterior Cervical System is also intended to restore the integrity of the spinal column even in the absence of fusion for a limited time period in patients with advanced stage tumors involving the cervical spine in whom life expectancy is of insufficient duration to permit achievement of fusion.

    In order to achieve additional levels of fixation, the Sovereign Posterior Cervical System may be connected to the Xultan 5.5 system using rod-to-rod connectors or transition rods. Please refer to the individual system's Instructions for Use for a list of indications for use for each system.

    Device Description

    The Met One Technologies Sovereign Posterior Cervical System is an implant device designed for the posterior stabilization of the cervical and upper thoracic spine. The system includes implants such as polyaxial screws, blocker screws, rods, crosslinks, lateral connectors, and rod to rod connectors to form a unique construct to match patient anatomy.

    Polyaxial screws are offered in a range of sizes in both standard and reduction tulips for ease of use. All screws are manufactured from titanium alloy (Ti-6Al-4V ELI per ASTM F136).

    Straight, pre-bent, and transition rods are offered in 3.5mm and 4.0mm diameters and in two different materials, titanium alloy (Ti-6Al-4V ELI per ASTM F136) and cobalt chrome (Co-Cr28-Mo6 per ASTM F1537). Transition rods are fully compatible with Met One Technologies Xultan 5.5 Pedicle Screw System line of implants.

    A variety of connectors and crosslinks are offered for surgeons to create the desired construction. Rod to rod crosslinks improve the torsional stability of the construct. Lateral connectors are provided in open and closed configurations, 3.5mm and 4.0mm diameters, and in long and short lengths. Rod to rod connectors are offered in several configurations to join rods together. All connectors are manufactured from titanium alloy (Ti-6Al-4V ELI per ASTM F136).

    AI/ML Overview

    I am sorry, but the provided text is an FDA 510(k) clearance letter for a Sovereign Posterior Cervical System, which is a physical medical device (spinal implant system), not an AI/Software as a Medical Device (SaMD).

    Therefore, the document does not contain any information about:

    • Acceptance criteria for an AI/SaMD's performance.
    • A study proving the device meets AI/SaMD acceptance criteria.
    • A test set (sample size, provenance).
    • Experts establishing ground truth.
    • Adjudication methods.
    • MRMC comparative effectiveness studies.
    • Standalone algorithm performance.
    • Types of ground truth.
    • Training set details.

    The non-clinical testing described (ASTM F1717 and ASTM F1798) refers to mechanical testing of the physical implant's strength and durability, not software performance.

    As such, I cannot fulfill your request for information related to AI/SaMD acceptance criteria and study details based on the provided input.

    Ask a Question

    Ask a specific question about this device

    K Number
    K242674

    Validate with FDA (Live)

    Date Cleared
    2025-05-13

    (249 days)

    Product Code
    Regulation Number
    888.3075
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    K242674**
    Trade/Device Name: Freedom Posterior Cervical Screws
    Regulation Number: 21 CFR 888.3075
    Fax: +61 (2) 8456 6065

    Date Prepared: May 1st, 2025

    Classification: Class II per 21 CFR 888.3075

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Signature Orthopaedics Freedom Cervical Screw and Rod System is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients (C1 to C7) as an adjunct to fusion in the treatment of the following acute and chronic instabilities and deformities of the cervical spine:

    • traumatic spinal fractures and/or traumatic dislocations
    • instability or deformity; failed previous fusions (e.g. pseudarthrosis)
    • degenerative disease, including neck and/or arm pain of discogenic origin as confirmed by radiographic studies, and degenerative disease of the facets with instability, and
    • short term stabilization of the spinal column even in the absence of fusion for a limited time period in patients with advanced stage tumors involving the cervical spine in whom expectancy is of insufficient duration to permit achievement of fusion.
    Device Description

    The Freedom™ Posterior Cervical Screw System consists of screws, longitudinal rods and cross connectors in a variety of sizes to accommodate differing anatomic requirements. The cervical screws are inserted into adjacent vertebrae, then rods are clamped into the tulip of the pedicle screw using the cap screw, thus immobilising the instrumented vertebrae. The cross-connector may then be attached between rods to improve stability. The system components are made of Ti6Al4V alloy and are supplied sterile.

    AI/ML Overview

    The provided FDA 510(k) clearance letter pertains to the Freedom Posterior Cervical Screws, which is a medical device and not an AI/ML-driven software system. As such, the information you've requested regarding acceptance criteria, study details, sample sizes, ground truth, and human reader performance is not applicable to this type of device submission.

    The FDA clearance for this device is based on demonstrating substantial equivalence to a legally marketed predicate device, primarily through non-clinical performance testing and engineering evaluations. These tests focus on the physical and mechanical properties of the screws to ensure they are safe and effective for their intended use as a spinal implant.

    Here's a breakdown of the relevant information provided in the document concerning the device's performance:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategorySpecific Tests PerformedReported Device Performance
    Mechanical Strength & DurabilityStatic and dynamic compression bending testingResults demonstrated that the strength of the system is sufficient for its intended use.
    Static torsion testingResults demonstrated that the strength of the system is sufficient for its intended use.
    Static Flexion-Extension Moment TestResults demonstrated that the strength of the system is sufficient for its intended use.
    Axial Gripping TestResults demonstrated that the strength of the system is sufficient for its intended use.
    Axial Torsional TestResults demonstrated that the strength of the system is sufficient for its intended use.
    Surgical Handling & IntegrationScrew insertion testingNot explicitly detailed performance, but implies successful insertion.
    Screw pull-out testingNot explicitly detailed performance, but implies adequate resistance to pull-out.
    Screw torque to failure testingNot explicitly detailed performance, but implies appropriate torque resistance.
    Compliance with StandardsAdherence to ASTM-F1717 (Spinal Implant Construct in a Vertebrectomy Model)Confirmed compliance with relevant standards.
    Adherence to ASTM-F1798 (Static and Fatigue Properties of Interconnection Mechanisms and Subassemblies Used in Spinal Arthrodesis Implants)Confirmed compliance with relevant standards.
    Adherence to ASTM-F543 (Metallic Medical Bone Screw)Confirmed compliance with relevant standards.
    Substantial EquivalenceComparison with Predicate Device (Saxxony™ Posterior Cervical Thoracic System - K182508)Demonstrated "nearly identical technological characteristics" and that "minor differences do not raise any new issues of safety and effectiveness."

    2. Sample size used for the test set and the data provenance:

    • The document states that "worst-case sizes of the subject cervical screws" were tested.
    • Sample size: Not explicitly quantified with a specific number of units, but implied it was a representative selection of "worst-case sizes."
    • Data provenance: The tests were "non-clinical testing and engineering evaluations" conducted by the manufacturer, Signature Orthopaedics Pty Ltd, in Australia. This is a form of prospective testing done specifically for regulatory submission.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Not applicable. This is a hardware device where "ground truth" is established through engineering principles and physical testing against established ASTM standards, not through expert human interpretation or diagnosis.

    4. Adjudication method for the test set:

    • Not applicable. This involves objective mechanical testing, where results are measured directly against predefined acceptance criteria from engineering standards. There is no subjective adjudication process for establishing a "ground truth" as would be the case for image interpretation or diagnostic performance.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • Not applicable. This device is a surgical implant, not an AI-assisted diagnostic tool. Therefore, no MRMC studies or human reader performance evaluations were conducted or are relevant.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • Not applicable. This is a physical product, not a software algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc):

    • The "ground truth" for this device's performance is derived from established mechanical and material engineering standards (ASTM standards). The device's components must meet or exceed the performance specifications (e.g., strength, fatigue resistance) outlined in these standards to be deemed safe and effective for their intended surgical purpose.

    8. The sample size for the training set:

    • Not applicable. This refers to a dataset used to train an AI model. This device is hardware and does not involve a training set.

    9. How the ground truth for the training set was established:

    • Not applicable. As above, there is no training set for this type of medical device submission.
    Ask a Question

    Ask a specific question about this device

    K Number
    K250332

    Validate with FDA (Live)

    Date Cleared
    2025-04-04

    (58 days)

    Product Code
    Regulation Number
    888.3075
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    K250332**
    Trade/Device Name: Virage® OCT Spinal Fixation System
    Regulation Number: 21 CFR 888.3075
    | Device Class | Class II |
    | Device Panel | Orthopedic Panel (87) |
    | Regulation Number | 21 CFR § 888.3075

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Virage® OCT Spinal Fixation System is intended to provide immobilization and stabilization of spinal segments as an adjunct to fusion for the following acute and chronic instabilities of the craniocervical junction, the cervical spine (C1-C7) and the thoracic spine from T1-T3; traumatic spinal fractures and/or traumatic dislocations; instability of deformity; failed previous fusions (e.g., pseudoarthorsis); tumors involving the cervical spine; and degenerative disease, including intractable radiculopathy and/or myelopathy, neck and/or arm pain of discogenic origin as confirmed by radiographic studies, and degenerative disease of the facets with instability. The Virage® OCT Spinal Fixation System is also intended to restore the integrity of the spinal column even in the absence of fusion for a limited time period in patients with advance stage tumors involving the cervical spine in whom life expectancy is of insufficient duration to permit achievement of fusion.

    In order to achieve additional levels of fixation, The Virage® OCT Spinal Fixation System may be connected to the Vital Spinal Fixation System offered by Highridge Medical, using rod connectors and transition rods. Refer to the Vital Spinal Fixation System package insert for a list of the system specific indications of use. The Vital/Vitality Spinal Fixation System implants are non-cervical spinal fixation devices intended for posterior pedicle screw fixation (T1-S2/ilium), posterior hook fixation (T1-L5), or anterolateral fixation (T8-L5).

    Device Description

    The Virage® OCT Spinal Fixation System is a posterior fixation system intended to provide immobilization and stabilization of the Occipital-Cervical-Thoracic spine (Occiput-T3). The system consists of a variety of rods, anchors, connectors, screws, and polyaxial screws to achieve an implant construct as necessary for the individual case. The system also includes the instruments necessary for inserting and securing the implants. The implant system is intended to be removed after solid fusion has occurred.

    The Virage® System implants are fabricated from medical grade titanium alloy and medical grade cobalt chromium alloy. Implants made from medical grade titanium, medical grade titanium alloy, and medical grade cobalt chromium may be used together.

    AI/ML Overview

    The provided FDA 510(k) clearance letter for the Virage® OCT Spinal Fixation System focuses on demonstrating substantial equivalence to a predicate device, rather than proving performance against specific acceptance criteria for an Artificial Intelligence (AI)/Machine Learning (ML) device.

    Therefore, many of the requested criteria, such as those pertaining to AI model performance (sample size for test/training sets, expert ground truth adjudication, MRMC studies, standalone performance), are not applicable to this submission. This document describes a traditional 510(k) for a spinal fixation system, not an AI/ML diagnostic or therapeutic device.

    However, I can extract the information that is relevant and state where the requested information is not applicable based on the provided document.


    Analysis of Acceptance Criteria and Device Performance (Based on Provided Document)

    The Virage® OCT Spinal Fixation System is a physical medical device (spinal fixation system), not an AI/ML software device. The "acceptance criteria" and "study that proves the device meets the acceptance criteria" in this context refer to mechanical testing and usability assessments to demonstrate substantial equivalence to a predicate device, not evaluation of an AI model's diagnostic or predictive performance.


    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategorySpecific Criteria (Goals)Reported Device Performance (Conclusion)
    Mechanical PerformanceMeet ASTM F1717 standards (Static Torsion, Dynamic/Static Compression Bending for Spinal Implant Constructs in Vertebrectomy Mode)"Mechanical testing and usability were evaluated, which all met the acceptance criteria for the worst-case subject connectors."
    Meet ASTM F1798 standards (Axial/Torsional Grip Testing for Static and Fatigue Properties of Interconnection Mechanisms)"Mechanical testing and usability were evaluated, which all met the acceptance criteria for the worst-case subject connectors."
    UsabilityDevice is usable as intended."Mechanical testing and usability were evaluated, which all met the acceptance criteria..."
    PackagingPackaging integrity and safety maintained."...packaging, cleaning and sterilization were evaluated to determine no risks were introduced to the system."
    Cleaning and SterilizationDevice can be effectively cleaned and sterilized."...packaging, cleaning and sterilization were evaluated to determine no risks were introduced to the system."
    Risk AssessmentRisks are reduced as low as reasonably practicable, and no equally severe/probable alternative risks exist."A risk assessment was conducted that found risks have been reduced as far as possible and neither alternative design nor therapeutic options exist to avoid the introduced risks without introducing equally severe and/or probable risks."
    Substantial EquivalenceDemonstrate substantial equivalence to the predicate Virage® System (K153631) regarding intended use, indications for use, design, materials, manufacturing methods, fundamental technology, and operational principles."The Virage® System's indications for use, intended use, design, materials, and performance assessments are substantially equivalent to the currently marketed Virage® System. As such, Highridge Medical, LLC concludes that the subject Virage® System is substantially equivalent to the predicate Virage® System."
    MRI CompatibilityMeet ASTM F2052 (magnetically induced displacement force), ASTM F2182 (RF induced heating), ASTM F2213 (magnetically induced torque), and ASTM F2119 (MR image artifacts)."Based on testing of the Virage® System in a magnetic resonance environment, the labeling was updated to include the addition of 'MR Conditional information'."

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size for Test Set: Not applicable in the context of an AI/ML test set. The document refers to "worst-case subject connectors" for mechanical testing, implying specific samples of the device components were tested, but not a "test set" of patient data or images.
    • Data Provenance: Not applicable. The "data" are mechanical test results, not patient data.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    • Not Applicable. This is a physical device, not an AI/ML diagnostic tool that requires expert-established ground truth from images or patient data. Ground truth for mechanical testing would be defined by engineering specifications and standard test methods.

    4. Adjudication Method for the Test Set

    • Not Applicable. Adjudication methods (e.g., 2+1, 3+1) are for human expert consensus on medical images or patient outcomes, which is not relevant for mechanical testing of a spinal implant.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done

    • No. An MRMC study is used to evaluate the impact of an AI/ML system on human reader performance for tasks like diagnosis or detection. This is a mechanical device, so an MRMC study is not relevant.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Study was done

    • Not Applicable. This is a physical spinal implant, not a standalone algorithm.

    7. The type of Ground Truth Used

    • Mechanical Test Standards and Engineering Specifications: The "ground truth" for this device's performance evaluation is adherence to standardized mechanical testing protocols (ASTM F1717, ASTM F1798) and internal engineering specifications for safety and performance, demonstrating equivalence to the predicate device.
    • MRI Compatibility Standards: Compliance with relevant ASTM standards for MRI compatibility (F2052, F2182, F2213, F2119) serves as the ground truth for this aspect.

    8. The Sample Size for the Training Set

    • Not Applicable. This is not an AI/ML device that requires a training set.

    9. How the Ground Truth for the Training Set was Established

    • Not Applicable. This is not an AI/ML device that requires a training set or its associated ground truth establishment.

    Ask a Question

    Ask a specific question about this device

    K Number
    K242516

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-11-19

    (88 days)

    Product Code
    Regulation Number
    888.3075
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Re: K242516

    Trade/Device Name: EUROPA™ Posterior Cervical Fusion System Regulation Number: 21 CFR 888.3075
    | | 888.3075

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The EUROPA™ Posterior Cervical Fusion System is intended to provide immobilization and stabilization of spinal segments as an adjunct to fusion for the following acute and chronic instabilities of the cervical spine (C1 to C7) and the upper thoracic spine (T1 to T3):

    • · Traumatic spinal fractures and/or traumatic dislocations
    • · Instability or deformity
    • · Failed previous fusions (e.g. pseudarthrosis)
    • · Tumors involving the cervical/thoracic spine
    • · Degenerative disease, including intractable radiculopathy and/or myelopathy
    • · Neck and/or arm pain of discogenic origin as confirmed by radiographic studies
    • · Degenerative disease of the facets with instability

    The EUROPA™ Posterior Cervical Fusion System is also intended to restore the intearity of the spinal column even in the absence of fusion for a limited time period in patients with advanced stage tumors involving the cervical spine in whom life expectancy is of insufficient duration to permit achievement of fusion.

    In order to achieve additional levels of fixation, the EUROPA™ Posterior Cervical Fusion System may be connected to the EUROPA™ Pedicle Screw System via the rod to rod connectors.

    Device Description

    The EUROPA™ Posterior Cervical Fusion System is a posterior cervical screw system intended to provide structural stability and mechanical support to the cervical spine following posterior cervical fusion.
    The EUROPA™ Posterior Cervical Fusion System consists of rods manufactured from Molybdenum-47.5 Rhenium Alloy (MoRe) per ASTM F3273, pedicle screws and connectors manufactured from Titanium-6 Aluminum-4 Vanadium ELI per ASTM F136, and instrumentation manufactured from Stainless Steel per ASTM F899. The EUROPA™ Posterior Cervical Fusion System implants are offered in multiple configurations and different sizes to accommodate various patient anatomical requirements.
    The rods are provided sterile packed and are intended for single use only. The pedicle screws and connectors must be steam sterilized prior to use.

    AI/ML Overview

    The provided text is related to the FDA 510(k) clearance for the EUROPA™ Posterior Cervical Fusion System. It details the device's intended use, indications, and a summary of non-clinical tests conducted to demonstrate substantial equivalence to predicate devices.

    However, the request asks for information about the acceptance criteria and the study that proves an AI/software device meets the acceptance criteria, including details like sample size, ground truth establishment, expert qualifications, and MRMC studies.

    The EUROPA™ Posterior Cervical Fusion System is a physical medical device (a posterior cervical screw system), not an AI or software device. The provided document does not contain any information about AI/software performance, nor does it describe studies with human readers, radiologists, or ground truth established by experts for an AI system.

    Therefore, I cannot extract the requested information regarding AI/software device acceptance criteria and study details from the provided text. The document focuses on demonstrating the mechanical performance and material equivalence of a physical implant system.

    Ask a Question

    Ask a specific question about this device

    K Number
    K233989

    Validate with FDA (Live)

    Date Cleared
    2024-03-27

    (100 days)

    Product Code
    Regulation Number
    888.3075
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    : K233989

    Trade/Device Name: CarboClear® Posterior Cervical Screw System Regulation Number: 21 CFR 888.3075
    Cervical Spine Fixation

    Classification Name

    Orthopedic; Posterior Cervical Screw System (21 CFR §888.3075

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The CarboClear® Posterior Cervical Screw System is intended to restore the integrity of the spinal column even in the absence of fusion for a limited time period in patients with advanced stage tumors involving the cervical spine in whom life expectancy is of insufficient duration to permit achievement of fusion.

    Device Description

    The CarboClear® Posterior Cervical Screw System ("CarboClear® System") is composed of implants in various dimensions, used to build a spinal construct; and of a set of instruments, intended to assist in the insertion and placement of the implants. The CarboClear® System is a posterior, cervical screw fixation system, intended to provide immobilization and stabilization of cervical spinal segments in oncological patients.

    The CarboClear® System implants include posterior screws, rods and locking elements (set screw). The implants are made mainly of carbon fiber-reinforced polyetheretherketone (CFR-PEEK). The threaded portion and the spherical head of the screw are encased within a thin titanium shell, and may include a tantalum marker.

    AI/ML Overview

    I am sorry, but the provided text does not contain information about the acceptance criteria and the study that proves a device meets acceptance criteria in the context of an AI/ML-driven medical device. The document is a 510(k) clearance letter from the FDA for a CarboClear® Posterior Cervical Screw System, which is a physical implant, not a software or AI/ML device.

    The document discusses:

    • Device Name: CarboClear® Posterior Cervical Screw System
    • Regulation Number: 21 CFR 888.3075 (Posterior Cervical Screw System)
    • Regulatory Class: Class II
    • Product Code: NKG
    • Indications for Use: Restoring spinal column integrity in patients with advanced stage tumors involving the cervical spine for a limited time.
    • Device Description: Implants (screws, rods, locking elements) made of carbon fiber-reinforced PEEK, with titanium shells and tantalum markers, and associated instruments.
    • Substantial Equivalence: Comparison to predicate devices (Synapse OCT System, Mesa Mini Spinal System, CarboClear® X Pedicle Screw System) based on indications for use, design, materials, technological characteristics, principles of operation, and performance characteristics (static and dynamic tests according to ASTM standards).

    There is no mention of an AI/ML component, algorithm performance, ground truth establishment, expert review, or any of the specific criteria related to an AI/ML performance study as requested in your prompt.

    Therefore, I cannot extract the information required to populate the table or answer the questions related to acceptance criteria and study proving device meets acceptance criteria for an AI/ML device from this document.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 6