Search Filters

Search Results

Found 61 results

510(k) Data Aggregation

    K Number
    K251946

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-08-29

    (65 days)

    Product Code
    Regulation Number
    872.3690
    Panel
    Dental
    Age Range
    0 - 21
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Adhesive, Bracket And Tooth Conditioner, Resin
    Device Classification: Class II, 872.3690, 872.3275, 872.3765

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    1. Direct restorative for Class I, II, III, IV, and V cavities
    2. Fissure sealant
    3. Sealing hypersensitive areas
    4. Repair of (in)direct aesthetic restorations, temporary crown & bridge, defect margins when margins are in enamel
    5. Blocking out undercuts
    6. Liner or base
    7. Core build-up
    8. Adhesive cementation of ceramic and composite veneers, inlays and onlays with a thickness (<2.0 mm) and translucency that enables the complete light curing of the cement
    9. Retention of aligner e.g. by fabrication of aligner attachments
    Device Description

    G-ænial Universal Injectable II is a light-cured, nano-filled radiopaque composite resin filled in syringe. The device is used for the restoration of both anterior and posterior teeth, core build-up, adhesive cementation of ceramic and composite veneer, inlays and onlays, and build-up for transparent removable orthodontic retainers. The device is available in 9 shades.

    AI/ML Overview

    This document is an FDA 510(k) clearance letter for a dental resin material, G-ænial Universal Injectable II. It is important to note that this is NOT an AI/ML medical device submission. Therefore, the information provided in the document focuses on the material's physical and chemical properties and biocompatibility, as compared to predicate dental materials.

    The request asks for information typically found in submissions for AI/ML medical devices, such as acceptance criteria based on diagnostic performance metrics (e.g., sensitivity, specificity, AUC), details about test and training sets, expert consensus for ground truth, MRMC studies, and effect sizes of AI assistance. Since this is a dental material, these types of studies are not relevant and are not present in the provided document.

    Therefore, the following response will adapt the requested sections to the context of this dental material, explaining what information is available and what is not, given the nature of the device.


    Acceptance Criteria and Device Performance for G-ænial Universal Injectable II

    The acceptance criteria for G-ænial Universal Injectable II are based on established ISO standards for dental materials and FDA guidance for composite resin devices. The "study that proves the device meets the acceptance criteria" refers to the Performance Bench Tests and Non-Clinical Performance Testing detailed in Section 7 and 8 of the 510(k) summary. These tests assess the physical, chemical, and biological properties of the material.

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria are generally "Complies" with specific quantitative or qualitative thresholds defined by the standards (e.g., ISO 4049, ISO 6874). The document reports that the device Complies with all listed requirements.

    PropertyAcceptance Criterion (Requirement from Standards/Guidance)Reported Device Performance (G-ænial Universal Injectable II)
    Film thickness50 µm or less.Complies
    Sensitivity to lightRemain physically homogeneous.Complies
    Depth of cure (ISO 4049)Opaque shade; 1.0 mm or moreOther shade; 1.5 mm or moreComplies
    Flexural strength80 MPa or more.Complies
    Water sorption40 µg/mm³ or lessComplies
    Solubility7.5 µg/mm³ or lessComplies
    Shade of restoration materialsClosely match the shade of the shade guide. Shall be evenly pigmented.Complies
    Colour stability after irradiation and water sorptionNo more than slight change in colour.Complies
    Radio-opacityEqual to or greater than the radio-opacity of the same thickness of aluminium.Complies
    Depth of cure (ISO 6874)1.5 mm or moreComplies
    Compressive strength100 MPa or more.Complies
    Elastic modulusEquivalent or more than predicate device.Complies
    Surface hardnessEquivalent or more than predicate device.Complies
    Adhesive bond strengthEquivalent or more than predicate device.Complies
    Filler particle size0.01 - 0.5 μm (as per product description)This is a characteristic, not an acceptance criterion, but the device meets this range.

    2. Sample Size Used for the Test Set and Data Provenance

    For a dental material, the "test set" refers to the samples of the material manufactured and subjected to the performance bench tests and biocompatibility assessments.

    • Sample Size: The document does not specify the exact number of samples (e.g., number of specimens for flexural strength, number of animals for biocompatibility tests). It simply states that "Performance testing includes" and "A biocompatibility assessment was completed."
    • Data Provenance: The data provenance is internal to the manufacturer (GC America, Inc.) and derived from laboratory testing of the material according to international ISO standards and FDA guidance documents. There is no indication of "country of origin of the data" in the sense of patient data, nor is it a retrospective or prospective study in the clinical trial sense. These are laboratory-based material characterization tests.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    This question is not applicable to a dental material submission. The "ground truth" for material properties is established by the standardized test methods themselves (e.g., ISO 4049 defines how depth of cure is measured). There are no "experts" establishing ground truth in the sense of clinical interpretations or diagnoses. The expertise lies in adhering to the established test protocols and analyzing results accurately by qualified laboratory personnel.

    4. Adjudication Method for the Test Set

    This concept is not applicable for dental material performance testing. Adjudication methods (like 2+1, 3+1 consensus) are used in studies involving human interpretation of images or clinical outcomes, typically for AI/ML device validation. Here, tests are quantitative measurements of physical/chemical properties or biological responses.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done, and Effect Size of Human Readers Improving with AI vs Without AI Assistance

    This question is not applicable. G-ænial Universal Injectable II is a dental restorative material, not an AI-assisted diagnostic or therapeutic device. There are no "human readers" involved in interpreting its performance, nor does it assist human readers. Therefore, no MRMC study was performed, and no effect size on human reader improvement with AI assistance can be reported.

    6. If a Standalone (i.e., Algorithm Only Without Human-in-the-Loop Performance) was Done

    This question is not applicable. G-ænial Universal Injectable II is a physical dental material, not an algorithm. There is no "standalone performance" of an algorithm. Its performance is measured directly through laboratory tests of its inherent material properties.

    7. The Type of Ground Truth Used (Expert Consensus, Pathology, Outcomes Data, etc.)

    For dental materials, the "ground truth" is based on:

    • Standardized Test Methods: Adherence to established ISO standards (e.g., ISO 4049, ISO 6874, ISO 10993) defines the "truth" for material properties like flexural strength, depth of cure, water sorption, and biocompatibility.
    • Predicate Device Comparison: Performance is also evaluated in comparison to predicate devices, where "equivalence" often serves as a benchmark for acceptance.

    There is no "expert consensus," "pathology," or "outcomes data" in the sense of human diagnostic performance or clinical trial results, as this is a pre-market notification for a material.

    8. The Sample Size for the Training Set

    This question is not applicable. There is no "training set" for a dental material in the context of machine learning. The material itself is manufactured, and specific properties are tested for quality control and regulatory submission.

    9. How the Ground Truth for the Training Set was Established

    This question is not applicable, as there is no training set.

    Ask a Question

    Ask a specific question about this device

    K Number
    K243254

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-08-08

    (297 days)

    Product Code
    Regulation Number
    872.3765
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    20024

    Re: K243254
    Trade/Device Name: Parkell Pit and Fissure Sealant
    Regulation Number: 21 CFR 872.3765
    layer" of composite restorations |
    | Classification Product Code | EBC | EBC |
    | Regulation Number | 872.3765
    | 872.3765 |
    | Principle of operation | Prophylactic sealing of pits and fissures | Prophylactic sealing
    layer" of composite restorations |
    | Classification Product Code | EBC | EBC |
    | Regulation Number | 872.3765
    | 872.3765 |
    | Principle of operation | Prophylactic sealing of pits and fissures | Prophylactic sealing

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Parkell Pit and Fissure Sealant is indicated for prophylactic sealing of pits and fissures as well as for micro-restorative procedures for composite restorations.

    Device Description

    The Device is a light-cured, flowable, resin-based sealant for prophylactic sealing of pits and fissures as well as for micro-restorative procedures. The Device is light-curable under standard power (600 mW/cm²) and contains filling agents which cause the Device to release and recharge beneficial ions (fluoride and calcium).

    AI/ML Overview

    The provided text describes the 510(k) clearance for the "Parkell Pit and Fissure Sealant." However, the clearance letter and accompanying 510(k) summary pertain to a physical dental device (a sealant), not an AI/software medical device.

    Therefore, many of the requested criteria regarding AI/software performance studies (such as sample size for test/training sets, data provenance, expert ground truth, adjudication methods, MRMC studies, standalone performance, etc.) are not applicable and are not mentioned in this document.

    The document focuses on the physical and chemical properties of the sealant and compares them to a predicate device. The performance data is based on non-clinical, in-vitro testing of these physical properties.

    Below is the information that can be extracted from the provided text, adapted as best as possible to the requested format, with clear indications where information is not applicable (N/A) due to the nature of the device.


    Acceptance Criteria and Device Performance for Parkell Pit and Fissure Sealant

    This device is a physical dental sealant, not an AI/software medical device. Therefore, the performance evaluation focuses on physical and chemical properties and biocompatibility, not algorithmic performance on image data.

    1. Table of Acceptance Criteria and Reported Device Performance

    PropertyAcceptance Criteria (Pass/Fail)Reported Device Performance (Parkell Pit and Fissure Sealant)
    Bond Strength to Dry Enamel≥10 MPa≥10 MPa
    Compressive Strength≥200 MPa≥200 MPa
    Flexural Strength≥90 MPa≥90 MPa
    Depth of Cure1.5-2.5 mm1.5-2.5 mm
    Shrinkage≤8%≤8%
    Viscosity (initial)1-5 Pa.s1-5 Pa.s
    Shelf LifeNot explicitly stated2 years (established by testing)
    Material BiocompatibilitySubstantially equivalent to predicate deviceSubstantially equivalent to predicate device
    Beneficial Ion ReleaseFluoride & CalciumFluoride & Calcium (vs. Predicate's Fluoride, Calcium, Phosphate)

    2. Sample size used for the test set and the data provenance

    • Sample Size: Not specified in the document. The testing was non-clinical (in-vitro).
    • Data Provenance: Non-clinical physical property testing. Not applicable for geographical or retrospective/prospective distinctions.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • N/A. This is a physical dental material. "Ground truth" in this context typically refers to objective measurements from laboratory testing equipment (e.g., universal testing machines for strength, viscometers for viscosity, etc.), not expert interpretation of data like in AI/imaging studies.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • N/A. As above, this is laboratory-based physical property testing, not subjective assessment requiring adjudication.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • N/A. This is not an AI-assisted device. No MRMC study was performed.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    • N/A. This is not an algorithm. Standalone performance is not applicable.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    • Laboratory Standard Measurements / In-vitro physical property testing. The performance criteria (e.g., strength in MPa, shrinkage in %, viscosity in Pa.s) are based on standardized tests for dental materials.

    8. The sample size for the training set

    • N/A. This is not an AI/machine learning device. No training set was used.

    9. How the ground truth for the training set was established

    • N/A. As above, no training set was used.
    Ask a Question

    Ask a specific question about this device

    K Number
    K232498

    Validate with FDA (Live)

    Date Cleared
    2023-08-18

    (1 days)

    Product Code
    Regulation Number
    872.3765
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    plus - Bioprotection by Nobio, UltraSeal XT hydro - Bioprotection by Nobio Regulation Number: 21 CFR 872.3765
    |
    | Regulation Number: | 21 CFR 872.3765

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    UltraSeal XT plus bioprotection by Nobio sealant - UltraSeal XT plus sealant for prophylactic sealing of pits and fissures and can be used where the use of a flowable composite is indicated. The bioprotection by Nobio reduces demineralization, which is part of the caries formation process.

    UltraSeal XT hydro bioprotection by Nobio sealant - Use UltraSeal XT hydro sealant for prophylactic sealing of pits and fissures. The addition of the bioprotection by Nobio reduces demineralization, which is part of the caries formation process.

    Device Description

    UltraSeal XT plus bioprotection by Nobio sealant and flowable composite – UltraSeal XT plus sealant is a 58% filled, light-cured, radiopaque, methacrylate-based, thixotropic resin sealant. It is used with PrimaDry drying and priming agent to aid in avoiding moisture contamination which can cause microleakage and poor retention. It is a Type 1 Class 2 Group 1 polymer-based dental restorative flowable resin which is suitable for occlusal surfaces. It can be used where the use of a flowable is indicated. It is compatible with adhesives and bonding agents. UltraSeal XT plus sealant has a radiopacity value of 1.44 mm of aluminum. Aluminum has a radiopacity equivalent to that of dentin. Thus, 1 mm of material (having a radiopacity equivalent to 1 mm of aluminum) has a radiopacity equivalent to that of dentin-and 2 mm of aluminum is equivalent to enamel. The addition of the bioprotection by Nobio reduces demineralization, which is part of the caries formation process.

    UltraSeal XT hydro bioprotection by Nobio sealant – UltraSeal XT hydro sealant is a Class 2, 53% filled, light-cured, radiopaque, methacrylate-based, thixotropic resin sealant. It is partly hydrophobic and hydrophilic before it is cured, hydrophobic once cured, and has a selfadhesive quality. UltraSeal XT hydro sealant chemistry provides the option of a visual verification for marginal retention-with the use of a black light upon placement and at recall visits. The UV light is not included in the UltraSeal XT hydro sealant kit. The addition of the bioprotection by Nobio reduces demineralization, which is part of the caries formation process.

    Some of the silica-based filler particles (max 1.2% wt/wt of the total formulation) contained in all the UltraSeal XT plus Bioprotection by Nobio and UltraSeal XT hydro Bioprotection by Nobio are decorated with quaternary ammonium functional groups that are covalently bound to the filler particles' silica core via a silane linker (herein referred to as "QASi"). Following light induced polymerization, QASi particles (produced by Nobio) remain permanently entrapped within the sealant and destroy microorganisms by contact. As the cell membrane of microorganisms is negatively charged and the QASi particles have strong positive charges, microorganisms are electrostatically attracted to the positively charged cured material's surface resulting in disruption of their cell membrane and immediate microbial lysis.

    Both subject devices have a depth of cure ≥ 1.5mm, are curable at wavelengths of 385-515nm and will remain uncured after light exposure while in their primary container. UltraSeal XT plus Bioprotection by Nobio is also indicated for use as a flowable composite. It has a flexural strength of ≥ 80 MPa, Water Sortpion ≤ 40 µ g/mm3, Water Solubility ≤ 7.5 µ g/mm3, Radio-Opacity, ≥ 1mm of Al, Surface Hardness ≥ 20 HK and Ambient light sensistivity resulting in the product being physically homogeneous after 60 seconds.

    AI/ML Overview

    The provided text focuses on the substantial equivalence determination for dental sealants and does not contain information about a medical device involving AI or machine learning. Therefore, I cannot extract acceptance criteria and study details related to AI/ML device performance from this document.

    The document discusses physical and chemical properties of dental sealants and their biocompatibility, which are typically evaluated through bench testing and ISO standards, not through clinical studies with human readers or AI algorithms. As such, information regarding sample sizes for test sets, data provenance, expert adjudication, MRMC studies, standalone performance, training sets, or ground truth establishment in the context of AI/ML is absent.

    Ask a Question

    Ask a specific question about this device

    K Number
    K230455

    Validate with FDA (Live)

    Date Cleared
    2023-07-25

    (154 days)

    Product Code
    Regulation Number
    872.3765
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Province 276800 CHINA

    Re: K230455

    Trade/Device Name: Enamel Coating Resin Regulation Number: 21 CFR 872.3765

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Proseal Enamel Coating Resin is a light curing material for sealing the enamel pits and fissures of teeth.

    Device Description

    Proseal Enamel Coating Resin is a light-curing fissure sealant and is mainly composed of methacrylate resin, photo initiator system and inorganic fillers. It is packaged in syringes or bottles.

    AI/ML Overview

    This document is a 510(k) Summary for the Proseal Enamel Coating Resin. It focuses on demonstrating substantial equivalence to a predicate device rather than presenting a study proving a device meets specific acceptance criteria for performance in a diagnostic or clinical setting.

    Therefore, many of the requested fields cannot be filled from the provided text as they relate to the performance of an AI/diagnostic device, which is not what this document describes.

    Here's an analysis based on the available information:

    1. A table of acceptance criteria and the reported device performance

    The document states that in-vitro bench tests were performed and that the "test results indicated that the Proseal Enamel Coating Resin meets the pass/fail criteria and supports substantial equivalence when compared to the predicate device on physical properties." It also notes that the device is classified as Class 2 sealant in accordance with ISO 6874:2015.

    The specific acceptance criteria (pass/fail criteria) are implied to be derived from ISO 6874:2015 and FDA guidance "Dental Composite Resin Devices - Premarket Notification [510(k)] Submissions Document issued on: October 26, 2005". However, the document does not list the specific numerical acceptance criteria.

    The reported device performance is only described qualitatively as "meets the pass/fail criteria." Specific numeric performance values for each test (depth of cure, flexural strength, shear bonding strength, compressive strength, water sorption, solubility, film thickness, and elastic modulus) are not provided in this summary.

    Acceptance Criteria (Derived from ISO 6874:2015 & FDA Guidance)Reported Device Performance
    (Specific numerical criteria not detailed in the document)Meets criteria
    Depth of CureMeets criteria
    Flexural StrengthMeets criteria
    Shear Bonding StrengthMeets criteria
    Compressive StrengthMeets criteria
    Water SorptionMeets criteria
    SolubilityMeets criteria
    Film ThicknessMeets criteria
    Elastic ModulusMeets criteria

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document mentions "in-vitro bench tests" for physical properties and "Biocompatibility tests" but does not specify the sample size for these tests. Data provenance (country of origin, retrospective/prospective) is not mentioned for the testing.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    Not applicable. This is a material science study, not a study evaluating human expert performance or diagnostic accuracy.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable. This is a material science study.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is a material science product, not an AI or diagnostic device that would involve human readers.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    Not applicable. This is a material science product.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    For the physical property tests, the "ground truth" would be the scientifically established and standardized measurement protocols and evaluation criteria defined by ISO 6874:2015 and FDA guidance for dental composite resin devices. For biocompatibility tests, the ground truth would be established by ISO 10993 standards.

    8. The sample size for the training set

    Not applicable. There is no AI algorithm being trained.

    9. How the ground truth for the training set was established

    Not applicable. There is no AI algorithm being trained.

    Ask a Question

    Ask a specific question about this device

    K Number
    K190998

    Validate with FDA (Live)

    Date Cleared
    2019-11-08

    (206 days)

    Product Code
    Regulation Number
    872.3765
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Illinois 60047

    Re: K190998

    Trade/Device Name: BA Pit & Fissure Sealant Regulation Number: 21 CFR 872.3765
    |
    | CFR Section | 21 CFR 872.3765
    | 21 CFR 872.3765
    | 21 CFR 872.3765
    company names.

    • BA Pit & Fissure Sealant is classified under product code EBC, with respect to 21 CRF 872.3765
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    BA Pit & Fissure Sealant is intended to seal pit and fissure depressions/faults in the biting surfaces of teeth. For dental professional use only.

    Device Description

    Pit and Fissure sealants are used as a preventive measure to fill defects and prevent decay within crevices, voids or fissures on the surface of teeth. These voids are more challenging to keep free of substances that can lead to caries and eventual breakdown of tooth structure. BA Pit & Fissure Sealant is a material designed to fill these voids with a wear resistant material, ultimately preserving natural tooth structure.

    BA Pit & Fissure Sealant is a light activated / photopolymerizable, glass filled, urethane dimethacrylate material that is placed onto an etched enamel surface and light activated for 20 seconds. The result after application is a tooth that has been sealed with a tough, wear resistant material.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and the study that proves the device meets them, based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    The document does not explicitly state "acceptance criteria" with numerical targets for each test. Instead, it presents the results of various non-clinical performance tests for the subject device (BA Pit & Fissure Sealant) and then compares them to a predicate device (Pulpdent (Activa) Pit & Fissure Sealant with MCP) and sometimes a reference device (Prevent Seal) to establish substantial equivalence. The "acceptance criterion" in this context is generally that the subject device's performance is "similar" or "equivalent" to the predicate device, or that any differences do not raise additional concerns regarding safety or efficacy.

    TestAcceptance Criteria (implied - "similar/equivalent to predicate/reference" or "no additional concerns")Reported Device Performance (BA Pit & Fissure Sealant)
    Compressive StrengthSimilar to predicate and reference devices.Exhibited very similar compressive strengths to the predicate device and reference device.
    Diametral Tensile StrengthSimilar to predicate device.Exhibited similar diametral tensile strength compared to the predicate device.
    Elastic ModulusLevel of flexibility that allows absorption of occlusal forces without damage, supporting efficacious use.Material is flexible and will absorb significant forces without reaching permanent deformation; deformation limited by tooth structure allows absorption of occlusal forces without damage.
    Working TimeEquivalent to predicate device.Unlimited working time, equivalent to the predicate device.
    Depth of CureVery similar to predicate device; minor differences acceptable for occlusal surface/thin layers and do not impact safety/efficacy.Exhibited a very similar depth of cure to the predicate device. Minor difference not a concern for pit and fissure sealants.
    Film ThicknessNearly equivalent to reference device.Nearly equivalent to the reference device.
    CytotoxicitySame result as predicate device.Provided the same result as the predicate device.
    Accelerated Shelf-Life (interim)"Passing" results at 18 months, supporting an 18-month shelf-life.All test points to-date have yielded "passing" results, supporting an 18-month shelf-life (interim analysis).
    Ion Release (Calcium, Phosphate, Fluoride)Measurable ions released; minor differences to predicate acceptable as oral environment naturally fluctuates, and concentrations are very low.Released measurable calcium, phosphate, and fluoride. Released more than predicate, but differences are low (ppm/ppb) and oral environment fluctuates, so no concerns. Substantial equivalence supported.

    2. Sample sizes used for the test set and the data provenance

    The document describes non-clinical benchtop testing. For these types of tests, sample sizes are typically specified within the referenced ISO or ADA standards. However, the exact sample sizes for each specific test conducted for K190998 are not explicitly mentioned in the provided text.

    The data provenance is retrospective, as the tests were conducted prior to the 510(k) submission to demonstrate substantial equivalence. The country of origin of the data is not specified, but given the applicant is Apex Dental Materials, Inc. with an address in Lake Zurich, Illinois, it is likely the studies were conducted in the USA or by contract labs.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    This section is not applicable as the document describes non-clinical benchtop performance testing, not studies involving human interpretation or expert-established ground truth. The "ground truth" for these tests would be the measurement obtained from the laboratory instruments according to the specified standards.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    This section is not applicable as the document describes non-clinical benchtop performance testing, not studies involving human reading or adjudication.

    5. If a multi-reader, multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This section is not applicable. The device is "BA Pit & Fissure Sealant," which is a material used for dental sealing, not an AI-powered diagnostic or assistive tool for human readers. No MRMC study or AI component is mentioned.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done

    This section is not applicable. The device is a physical material (dental sealant), not an algorithm or software device.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The "ground truth" for the non-clinical tests is based on measurements obtained following standardized test methods (e.g., ISO, ADA standards). For example, for compressive strength, the ground truth is the force at which the material fractures, as measured by a testing machine according to the specified standard.

    8. The sample size for the training set

    This section is not applicable. The device is a physical material, not an AI model, and therefore does not have a "training set."

    9. How the ground truth for the training set was established

    This section is not applicable. The device is a physical material, not an AI model, and therefore does not have a "training set" or ground truth relevant to AI model training.

    Ask a Question

    Ask a specific question about this device

    K Number
    K190339

    Validate with FDA (Live)

    Device Name
    Helioseal F Plus
    Date Cleared
    2019-07-29

    (165 days)

    Product Code
    Regulation Number
    872.3765
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Amherst, New York 14228

    Re: K190339

    Trade/Device Name: Helioseal F Plus Regulation Number: 21 CFR 872.3765
    |
    | Classification Name: | Sealant, pit and fissure, and conditioner Resin (872.3765

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Helioseal F Plus is used to seal fissures, pits and foramina caeca.

    Device Description

    Helioseal® F Plus is a light-curing, white shaded fissure sealant featuring fluoride release. Helioseal F Plus is supplied in either a syringe or cavifil delivery form. The fissure sealant is composed of dimethacrylates. In the handling technique, the dental professional will clean the enamel surface to be sealed, isolate the working field, conditioning is performed, a thorough rinse and dry to remove the conditioner, before the application of Helioseal F Plus to the tooth surface.

    AI/ML Overview

    This document is a 510(k) premarket notification for a dental device, specifically a pit and fissure sealant. It demonstrates substantial equivalence to a predicate device, rather than providing a performance study proving a device meets specific acceptance criteria as would be typical for an AI/ML medical device.

    Therefore, the requested information regarding acceptance criteria, study design for AI/ML performance, sample sizes, expert involvement, ground truth establishment, and MRMC studies is not applicable to this document.

    The document primarily focuses on demonstrating equivalence through:

    • Comparison to Predicate Device: Detailed comparison of indications for use, contraindications, technology, principles of operation, and physical properties between Helioseal F Plus (subject device) and Helioseal F (predicate device).
    • Bench Testing: Non-clinical performance testing for physical properties (flexural strength, curing depth, light intensity, wavelength for curing, water sorption, water solubility, radio-opacity) in accordance with FDA Guidance and EN ISO 6874:2015.
    • Biocompatibility Testing: Evaluation for cytotoxicity and genotoxicity according to ISO 10993-1, ISO 7405, and ISO 14971.

    The conclusion states that the devices are substantially equivalent, implying that the new device performs similarly to the already legally marketed predicate device. There are no acceptance criteria, in the sense of accuracy/recall/precision metrics for an AI/ML algorithm, or a human reader study, included in this type of submission.

    Ask a Question

    Ask a specific question about this device

    K Number
    K172169

    Validate with FDA (Live)

    Date Cleared
    2018-01-05

    (171 days)

    Product Code
    Regulation Number
    872.3765
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    K172169

    Trade/Device Name: Pulpdent (Activa) Pit and Fissure Sealant with MCP Regulation Number: 21 CFR 872.3765
    Review Panel: Dental Classification Name: Pit and Fissure Sealant FDA Product Code: EBC, 21 CFR Part 872.3765
    substantially equivalent under the 510(k) Premarket Notification process as Class II Dental Device under CFR 872.3765
    substantially equivalent under the 510(k) Premarket Notification process as Class II Dental Devices under CFR 872.3765

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Pulpdent's Activa Pit and Fissure Sealant with MCP is intended to seal pit and fissure depressions/faults in the enamel, in the biting surfaces of teeth. For dental professional use only.

    Device Description

    Activa Pit and Fissure Sealant is a light cured, flowable dental sealant material, available in a single barrel syringe. This sealant is designed with MCP (Modified Calcium Phosphate); it releases calcium, phosphate, and fluoride ions into the oral environment. It contains no Bisphenol A, no BisGMA, and no BPA derivatives.

    AI/ML Overview

    This document is a 510(k) premarket notification for a dental pit and fissure sealant. It does not describe an AI/ML-driven medical device, and therefore the requested information regarding acceptance criteria and study data for an AI/ML device is not present in the provided text.

    The document discusses substantial equivalence to a predicate device based on material composition, intended use, and physical properties, not on performance metrics of an AI algorithm.

    Therefore, I cannot extract the information required by your prompt from the provided text.

    Ask a Question

    Ask a specific question about this device

    K Number
    K171330

    Validate with FDA (Live)

    Device Name
    Nanova Sealant
    Date Cleared
    2017-09-08

    (126 days)

    Product Code
    Regulation Number
    872.3765
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Columbia, Missouri 65202

    Re: K171330

    Trade/Device Name: Nanova™ Sealant Regulation Number: 21 CFR 872.3765

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Nanova Sealant is indicated for use as a pit and fissure sealant

    Device Description

    Not Found

    AI/ML Overview

    This document is a 510(k) clearance letter for the Nanova™ Sealant, a pit and fissure sealant. It confirms that the device has been found substantially equivalent to a predicate device.

    However, the provided text does NOT contain any information about acceptance criteria, device performance studies, sample sizes, ground truth establishment, expert qualifications, adjudication methods, or MRMC studies.

    The document is a regulatory communication from the FDA, and while it confirms the device can be legally marketed, it does not detail the technical performance studies that would typically be included in a 510(k) submission to demonstrate substantial equivalence. Such performance data would be in the original 510(k) submission (K171330), not in the clearance letter itself.

    Therefore, I cannot provide the requested information from the given text.

    Ask a Question

    Ask a specific question about this device

    K Number
    K162598

    Validate with FDA (Live)

    Device Name
    HAPI Seal
    Manufacturer
    Date Cleared
    2017-05-23

    (246 days)

    Product Code
    Regulation Number
    872.3765
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Schaumburg, Illinois 60193

    Re: K162598

    Trade/Device Name: HAPI Seal Regulation Number: 21 CFR 872.3765
    Name: HAPI Seal Pit & Fissure Sealant ЕВС Pit and fissure sealant and conditioner Class II per 21 CFR 872.3765

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Pit and fissure sealant

    Device Description

    HAPI Seal is a light-cured, fluoride containing, resin-based pit & fissure sealant designed for sealing the enamel pits and fissures of teeth.

    AI/ML Overview

    The provided text is a 510(k) summary for a dental device, HAPI Seal, and does not describe a study involving an AI algorithm or human readers. Therefore, several of the requested categories (2, 3, 4, 5, 6, 7, 8, 9) are not applicable.

    Here's the information that can be extracted from the document:

    1. Table of acceptance criteria and the reported device performance:

    Acceptance Criteria / RequirementReported Device Performance
    Depth of CureHAPI Seal meets the requirements of ISO 6874:2015.
    Flexural StrengthHAPI Seal meets the requirements of ISO 4049:2009 for Flexural Strength.
    Shear Bond Strength (Modified ISO 29022)HAPI Seal is equivalent to the predicate.
    Light Curability (Cure time)HAPI Seal is equivalent to the predicate.
    Ambient Light SensitivityHAPI Seal is equivalent to the predicate.
    Flexural Modulus (ANSI/ADA Spec No. 27)HAPI Seal is equivalent to the predicate.
    Cumulative Fluoride ReleaseHAPI Seal is equivalent to the predicate.
    Compressive Strength (ANSI/ADA Spec No. 27)HAPI Seal is equivalent to the predicate.
    Surface Hardness (Barcol-Colman 934-1)HAPI Seal is equivalent to the predicate.
    Shrinkage (Volumetric)HAPI Seal is equivalent to the predicate.
    Biocompatibility (Cytotoxicity, Oral Toxicity)HAPI Seal was not toxic in the oral toxicity test (10 mice, 14 days). An evaluation using ISO 7405:2008 and ISO 10993-1 was conducted.

    2. Sample size used for the test set and the data provenance:

    • Oral Toxicity Study: 10 mice were used for a 14-day study.
    • Other performance tests: The document mentions that HAPI Seal "meets" or is "equivalent" to the predicate for various physical/mechanical properties based on specific ISO or ANSI/ADA standards. However, it does not explicitly state the sample sizes used for these tests. The data provenance is not specified (e.g., country of origin, retrospective or prospective), but these are laboratory tests done to regulatory standards.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    This information is not applicable as the studies described are laboratory performance and biocompatibility tests, not studies requiring expert interpretation of data.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set:

    This information is not applicable.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    This information is not applicable.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

    This information is not applicable.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    The ground truth for the physical/mechanical properties and biocompatibility was established through adherence to recognized international and national standards (e.g., ISO 6874:2015, ISO 4049:2009, ISO 29022:2013, ANSI/ADA Spec No. 27, ISO 7405:2008, ISO 10993-1).

    8. The sample size for the training set:

    This information is not applicable as this is not an AI algorithm study.

    9. How the ground truth for the training set was established:

    This information is not applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    K161580

    Validate with FDA (Live)

    Device Name
    Premier Sealant
    Date Cleared
    2016-10-18

    (132 days)

    Product Code
    Regulation Number
    872.3765
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    Why did this record match?
    510k Summary Text (Full-text Search) :

    Meeting, Pennsylvania 19462

    Re: K161580 Trade/Device Name: Premier Sealant Regulation Number: 21 CFR 872.3765

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Premier Sealant, a prescription only medical device used for prophylactic sealing of pits and fissures. It may also be used for micro-restorative or "initial layer" of composite restorations.

    Device Description

    Not Found

    AI/ML Overview

    I am sorry, but the provided text from the FDA 510(k) premarket notification for the "Premier Sealant" does not contain any information about a medical device that uses artificial intelligence (AI) or machine learning.

    The document is a standard FDA clearance letter for a dental pit and fissure sealant, which is a physical product, not a software-based diagnostic or assistive device that would involve acceptance criteria for AI performance.

    Therefore, I cannot provide the requested information regarding:

    1. A table of acceptance criteria and reported device performance.
    2. Sample sizes for test set or data provenance.
    3. Number of experts or their qualifications for ground truth.
    4. Adjudication methods.
    5. MRMC comparative effectiveness study or human reader improvement with AI.
    6. Standalone algorithm performance.
    7. Type of ground truth used.
    8. Training set sample size.
    9. How ground truth for the training set was established.

    This information is simply not present in the provided text as the device in question is a traditional dental material, not an AI-powered diagnostic tool.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 7