510(k) Data Aggregation

    K Number
    K080069

    Validate with FDA (Live)

    Device Name
    DIMERTEST
    Date Cleared
    2008-02-13

    (34 days)

    Product Code
    Regulation Number
    864.7320
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K945642

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The DIMERTEST® Latex Assay is intended for the rapid qualitative or semi-quantitative evaluation of circulating derivatives of cross-linked fibrin degradation products (D-dimer) in human plasma.

    Device Description

    The DIMERTEST® Latex Kit is a qualitative and semi-quantitative latex agglutination slide test for cross-linked fibrin degradation products in human plasma. The active ingredient in the DIMERTEST® product is the latex reagent. This reagent consists of highly specific D-dimer monoclonal antibodies attached to polystyrene latex particles. When mixed with the latex reagent, the presence of antigen (Ddimer) in a plasma sample results in agglutination of the latex particles which can be seen with the unaided eye. A semi-quantitative estimate of the Ddimer concentration can be made by preparing dilutions of a plasma sample. The concentration is determined according to a titration matrix.

    Plasma from normal individuals is not expected to agglutinate DIMERTEST® Latex. Reactive fibrinolysis will be demonstrated by latex agglutination at a plasma concentration of approximately 200 ng/mL D-dimer.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and the study that proves the device meets them, based on the provided text:

    DIMERTEST® Device Acceptance Criteria and Performance Study

    The DIMERTEST® Latex Assay is intended for the rapid qualitative or semi-quantitative evaluation of circulating derivatives of cross-linked fibrin degradation products (D-dimer) in human plasma. The submission K974596 concerns a modified version of the DIMERTEST® product, where American Diagnostica Inc. (ADI) took over manufacturing from AGEN Biomedical Ltd. and made some changes, including a change in the latex supplier and a refined cut-off value.

    1. Table of Acceptance Criteria and Reported Device Performance

    The provided document doesn't explicitly state "acceptance criteria" with numerical targets in the conventional sense for a new device. Instead, it focuses on demonstrating substantial equivalence to an existing predicate device (DIMERTEST® K882944) by comparing performance characteristics. The implied acceptance criteria are that the modified device's performance (specificity, sensitivity, and analytical characteristics) is comparable to or improved from the predicate device and that the new cut-off is adequately validated.

    Criterion/Performance CharacteristicAcceptance Criteria (Implied for Substantial Equivalence to Predicate)Reported Device Performance (Modified DIMERTEST®)
    Precision/ReproducibilityConsistent results within and between runsIntra-assay: 10 replicates from three plasma pools (D-dimer titers 0 to 4) all had the same values. Inter-assay: 10 plasma pools (D-dimer titers 1 to 16) tested over 10 runs did not vary by more than 1 titer over 28 days.
    Reportable Range (Semi-quantitative)Clearly defined and validated range200 to 3,200 ng/mL D-dimer
    Analytical SpecificityNo significant interference from common plasma componentsNo assay interference detected when plasma samples were spiked with Bilirubin (0.2 mg/dL), Lipids (triglycerides) (30 mg/dL), Hemoglobin (5.0 mg/dL), Protein (gamma globulin) (0.06 g/mL). Reagents are insensitive to rheumatoid factor.
    Assay Cut-offEstablished and validated diagnostic thresholdNew cut-off: 200 ng/mL D-dimer. Validation: Calculated from 145 patient samples (comparison to predicate) and further validated with an additional 373 patient plasmas (comparison to FDA cleared Dimertest Gold EIA K945642).
    Specificity (compared to predicate)Comparable specificity to the predicate device95.3% negative results in normal blood bank donor samples (n=170) compared to 97.6% negative by the predicate DIMERTEST® reagent.
    Sensitivity (compared to predicate)Comparable sensitivity to the predicate device145 plasmas from hospital patients with a high probability of thrombotic conditions were analyzed. (The document describes the method for comparison but does not provide a direct single numerical sensitivity metric for the modified device compared to the predicate in this section).

    2. Sample Sizes and Data Provenance for Test Set

    • Specificity Comparison:
      • Sample Size: 170 Blood Bank donor plasma samples.
      • Data Provenance: In-house comparative study, ostensibly healthy volunteers. The country of origin is not specified but implied to be North America given the submitter's location (Stamford, CT). Retrospective.
    • Sensitivity Comparison:
      • Sample Size: 145 plasmas from hospital patients.
      • Data Provenance: In-house comparative study, patients with a high probability of thrombotic conditions. Country of origin not specified, implied North America. Retrospective.
    • Clinical Cut-off Validation:
      • Sample Size: 373 patient plasmas.
      • Data Provenance: Not explicitly stated, but these were "patient plasmas." Country of origin not specified, implied North America. Contemporaneous testing with an FDA-cleared EIA method suggests a prospective element to this validation step.

    3. Number of Experts and Qualifications for Ground Truth

    The document does not specify the use of experts to establish ground truth for the test set. For the normal donor samples, "ostensibly healthy volunteers" serve as the implicit negative ground truth. For the "hospital patients who had a high probability of thrombotic conditions," the "high probability" suggests clinical assessment as the ground truth, but specific details about how this was determined or by whom are not provided.

    4. Adjudication Method for Test Set

    The document does not describe any adjudication method for the test set. The results are presented as direct comparisons between the modified device and either the predicate device or a separate FDA-cleared EIA method.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    No MRMC comparative effectiveness study was done. This device is a biochemical assay (latex agglutination test), not an imaging or diagnostic device that typically involves human readers interpreting results in a complex way that requires AI assistance. The interpretation (agglutination or not) is largely qualitative or semi-quantitative based on visual inspection.

    6. Standalone Performance (Algorithm Only)

    This device is a standalone diagnostic kit (a latex agglutination assay) that produces a direct result. It does not involve an "algorithm" in the computational sense nor human-in-the-loop performance with an AI system. The performance characteristics described (precision, linearity, analytical specificity, cut-off validation, and method comparison) represent its standalone performance.

    7. Type of Ground Truth Used

    • Specificity Study: Implicitly, "normal individuals" from Blood Bank donor plasma samples served as the negative ground truth.
    • Sensitivity Study: Implicitly, "hospital patients who had a high probability of thrombotic conditions" served as the positive ground truth.
    • Cut-off Validation: The FDA cleared Dimertest Gold EIA method (K945642) served as a comparative reference for determining and validating the new cut-off. This could be considered a reference method ground truth.

    8. Sample Size for the Training Set

    The document does not explicitly mention a separate "training set" for the device's development or performance evaluation in the context of machine learning. The studies described are performance validation studies for the modified device. The 145 patient samples were used to calculate the new clinical cut-off and the 373 patient plasmas were used to validate it. These samples effectively functioned as the data used to refine and confirm a key aspect of the device's operation.

    9. How Ground Truth for the Training Set Was Established

    As there's no explicit "training set" in the machine learning sense, the ground truth for the data used to establish or validate the cut-off was as follows:

    • For the 145 patient plasmas used to calculate the new cut-off, the comparison was made against the D-dimer values determined by the predicate DIMERTEST® reagent.
    • For the 373 patient plasmas used to validate the new cut-off, the comparison was made against the results from the FDA cleared Dimertest Gold EIA method (K945642).
    Ask a Question

    Ask a specific question about this device

    K Number
    K972696

    Validate with FDA (Live)

    Device Name
    IL TEST D-DIMER
    Date Cleared
    1997-11-04

    (109 days)

    Product Code
    Regulation Number
    864.7320
    Age Range
    18 - 120
    Reference & Predicate Devices
    Why did this record match?
    Reference Devices :

    K945642

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    IL Test™ D-Dimer permits the quantitative in vitro diagnostic determination of D-Dimer in human plasma by turbidimetry.

    Device Description

    The IL Test™ D-Dimer Latex Reagent is a suspension of latex particles coated with a monoclonal antibody specific for the D-Dimer domain included in fibrin soluble derivatives. When plasma containing D-Dimer is mixed with the D-Dimer Latex Reagent and Reaction Buffer, the coated latex particles agglutinate. The degree of agglutination is directly proportional to the concentration of D-Dimer in the sample and is determined by measuring the decrease of the transmitted light caused by the aggregates (turbidimetric immunoassay).

    AI/ML Overview

    Here's an analysis of the acceptance criteria and study details for the IL Test™ D-Dimer, based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategorySpecific Criteria (Implicitly based on predicate equivalence)Reported Device Performance (IL Test™ D-Dimer)
    Correlation to Predicater ≥ 0.95 (typical for method comparison studies)0.998 on ACL 6000 and ACL Futura
    Precision (CV)Generally < 10% for clinical assaysACL 6000:4.4% (at 390 ng/mL)2.4% (at 888 ng/mL)2.2% (at 1055 ng/mL)ACL Futura:6.9% (at 411 ng/mL)2.1% (at 912 ng/mL)2.7% (at 1051 ng/mL)
    Intended UseQuantitative in vitro diagnostic determination of D-Dimer in human plasma by turbidimetryMatches predicate's intended use
    Safety and EffectivenessSubstantially equivalent to predicate deviceSubstantially equivalent to predicate device

    Note: The document doesn't explicitly state numerical acceptance criteria for correlation or precision. However, for a 510(k) submission, the device must demonstrate performance that is "substantially equivalent" to a legally marketed predicate device. This implies that the performance metrics (like correlation and precision) of the new device should be comparable to or better than generally accepted standards for such assays, and in this case, implicitly compared to the performance of the predicate device.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size: 105 plasma samples.
    • Data Provenance: Not explicitly stated (e.g., country of origin). The study involved "human plasma," which suggests it's likely from human subjects. The text does not specify if the data was retrospective or prospective, but clinical method comparison studies typically use prospectively collected or retrospectively accessed existing clinical samples.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    • Not applicable / Not explicitly stated. This study is a method comparison study between a new device and a predicate device (AGEN's Dimertest® Gold EIA Kit K945642). The "ground truth" for each sample's D-Dimer concentration is established by the reading from the predicate device itself. It doesn't involve expert interpretation of images or clinical outcomes that require a panel of human experts for ground truth establishment.

    4. Adjudication Method for the Test Set

    • Not applicable. As this is a quantitative assay comparison against a predicate device, there is no expert adjudication process for establishing ground truth for individual cases, unlike studies involving subjective interpretation (e.g., radiology reads). The agreement is based on numerical correlation between the two assay methods.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • No. This is not a MRMC comparative effectiveness study. It's a method comparison study for an in vitro diagnostic (IVD) assay, comparing the performance of a new automated D-Dimer test to an existing one. Such studies typically involve human readers interpreting complex medical data (like images) and analyzing the improvement with AI assistance.

    6. Standalone Performance Study

    • Yes. The data presented focuses on the standalone performance of the IL Test™ D-Dimer device. It evaluates its correlation with the predicate device and its precision independently. The device itself is an automated in vitro diagnostic test, meaning its output (D-Dimer concentration) is generated by the algorithm/instrument without direct human-in-the-loop interpretation during the measurement process.

    7. Type of Ground Truth Used

    • Comparison to a Predicate Device. The "ground truth" for the performance evaluation of the IL Test™ D-Dimer is the D-Dimer concentration determined by the legally marketed predicate device, AGEN's Dimertest® Gold EIA Kit (K945642). This is a common approach for IVD 510(k) clearances, demonstrating substantial equivalence rather than absolute accuracy against a gold standard like pathology or clinical outcomes for every sample.

    8. Sample Size for the Training Set

    • Not explicitly stated in the provided text. For IVD devices, a "training set" in the context of machine learning (AI) as commonly understood today (neural networks, etc.) is not typically described in these older 510(k) submissions, as these were often traditional algorithms/reagent systems. The "training" for such systems would involve assay development and optimization, which isn't described in terms of a specific data set size here. If the device uses a statistical model or calibration curve, the data used to establish that curve would be analogous to a training set, but its size is not specified.

    9. How the Ground Truth for the Training Set Was Established

    • Not applicable / Not explicitly stated. Similar to point 8, the concept of a "training set" with established ground truth for an AI algorithm is not directly relevant or explicitly discussed in this context. The "ground truth" for any internal calibration or development work for this type of turbidimetric immunoassay would typically involve reference materials with known D-Dimer concentrations, often calibrated against international standards if available, or against highly characterized internal reference preparations.