Search Filters

Search Results

Found 10 results

510(k) Data Aggregation

    K Number
    K253370

    Validate with FDA (Live)

    Device Name
    LOGIQ Totus
    Date Cleared
    2026-01-08

    (100 days)

    Product Code
    Regulation Number
    892.1550
    Age Range
    0 - 999
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K231989 LOGIQ E10s Diagnostic Ultrasound System, K231301 Vscan Air, K201768 Voluson E10, K220882 Vivid

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    LOGIQ Totus is intended for use by a qualified physician for ultrasound evaluation of Fetal/Obstetrics; Abdominal(including Renal, Gynecology/Pelvic), Pediatric; Small organ(Breast, Testes, Thyroid); Neonatal Cephalic; Adult Cephalic; Cardiac(Adult and Pediatric), Peripheral Vascular, Musculo-skeletal Conventional and Superficial; Urology(including Prostate); Transrectal; Transvaginal; Transesophageal and Intraoperative(Abdominal and Vascular).

    Modes of operation includes: B, M, PW Doppler, CW Doppler, Color Doppler, Color M Doppler, Power Doppler, Harmonic Imaging, Coded Pulse, 3D/4D Imaging mode, Elastography, Shear Wave Elastography, Attenuation Imaging and Combined modes: B/M, B/Color, B/PWD, B/Color/PWD, B/Power/PWD.

    The LOGIQ Totus is intended to be used in a hospital or medical clinic.

    Device Description

    The LOGIQ Totus is full featured, Track 3 device, primarily intended for general purpose diagnostic ultrasound system which consists of a mobile console approximately 490mm wide (monitor width: 545mm), 835mm deep and 1415~1815mm high that provides digital acquisition, processing and display capability. The user interface includes a computer keyboard, specialized controls, 14-inch LCD touch screen and color 23.8-inch LCD & HDU image display.

    AI/ML Overview

    The provided FDA 510(k) clearance letter and summary for the LOGIQ Totus Ultrasound System (K253370) describes the acceptance criteria and the study for the Ultrasound Guided Fat Fraction for adult imaging (UGFF) software feature. This feature is being added to the LOGIQ Totus and is similar to a previously cleared Siemens UDFF feature.

    Here's a breakdown of the requested information based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document describes the performance of the UGFF feature by comparing it to MRI Proton Density Fat Fraction (MRI-PDFF) and, in a separate confirmatory study, to a predicate UDFF device. The "acceptance criteria" are implied by the reported strong correlations and limits of agreement with these reference standards.

    Acceptance Criteria (Implied)Reported Device Performance (UGFF vs. MRI-PDFF - Primary Study, Japan)Reported Device Performance (UGFF vs. MRI-PDFF - Confirmatory Study, US/EU)Reported Device Performance (UGFF vs. UDFF - Confirmatory Study, EU)
    Strong correlation with MRI-PDFFCorrelation coefficient: 0.87Correlation coefficient: 0.90N/A (compared to UDFF instead of MRI-PDFF)
    Acceptable agreement (Bland-Altman) with MRI-PDFFOffset: -0.32% LOA: -6.0% to 5.4% 91.6% patients within ±8.4%Offset: -0.1% LOA: -3.6% to 3.4% 95.0% patients within ±4.6%N/A (compared to UDFF instead of MRI-PDFF)
    Strong correlation with predicate UDFF deviceN/AN/ACorrelation coefficient: 0.88
    Acceptable agreement (Bland-Altman) with predicate UDFF deviceN/AN/AOffset: -1.2% LOA: -5.0% to 2.6% All patients within ±4.7%
    No statistically significant effect of demographic confounders on measurementsConfirmed for BMI, SCD, and other demographic confounders on AC, BSC, and NSR.Not explicitly stated for confirmatory studies but implied.Not explicitly stated for confirmatory studies but implied.

    2. Sample Size Used for the Test Set and Data Provenance

    • Primary Study (UGFF vs. MRI-PDFF):

      • Sample Size: 582 participants
      • Data Provenance: External clinical study in Japan (Population: Asian). The study was retrospective or prospective is not specified, but the phrase "obtained from the liver of five hundred and eighty-two (582) participants" suggests a data collection event rather than a purely retrospective analysis of existing medical records. The study is described as an "external clinical study," further suggesting a dedicated data collection.
    • First Confirmatory Study (UGFF vs. MRI-PDFF):

      • Sample Size: 15 US patients and 5 EU patients (total 20 patients)
      • Data Provenance: US and EU patients. Demographic information on the 5 EU patients was unavailable. This was conducted as a "confirmatory study."
    • Second Confirmatory Study (UGFF vs. UDFF):

      • Sample Size: 24 EU patients
      • Data Provenance: EU patients. This was conducted as a "confirmatory study."

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    The document does not specify the number of experts or their qualifications for establishing the ground truth.

    4. Adjudication Method for the Test Set

    The document does not specify an adjudication method. For the UGFF feature, the "ground truth" was objective measurements (MRI-PDFF or a predicate device's UDFF), which typically do not require adjudication by human experts in the same way an image diagnosis might.

    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study Was Done

    No, an MRMC comparative effectiveness study was not done for the UGFF feature as described. The studies focused on comparing the device's output (UGFF index) to an objective reference standard (MRI-PDFF or another device's UDFF), not on how human readers' performance improved with or without AI assistance.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    Yes, a standalone performance evaluation was done. The UGFF index, based on acoustic property measurements, is compared directly to MRI-PDFF and UDFF. This indicates the algorithm's performance independent of human interpretation or intervention in the final measurement calculation. While a technologist operates the ultrasound system, the UGFF index calculation itself is an algorithmic output.

    7. The Type of Ground Truth Used

    The type of ground truth used is MRI Proton Density Fat Fraction (MRI-PDFF) measurements, which are quantitative and objective reference standards for liver fat quantification. Additionally, for one confirmatory study, the ground truth was the Ultrasound-Derived Fat Fraction (UDFF) from a Siemens Acuson S3000/S2000, functioning as a predicate device's output. These are akin to "outcomes data" or "established reference standard measurements."

    8. The Sample Size for the Training Set

    The document states: "During the migration of the AI software feature from LOGIQ E10s (K231989), the algorithm was not retrained and there were no changes to the algorithmic flow or the AI components performing the inferencing." This implies the training set was associated with the original clearance of the Auto Renal Measure Assistant on the LOGIQ E10s (K231989) but the sample size for the training set is not provided in this document.

    9. How the Ground Truth for the Training Set Was Established

    Similarly, since the algorithm was not retrained and the document pertains to the migration of an existing AI feature, the method for establishing the ground truth for the original training set is not provided in this document.

    Ask a Question

    Ask a specific question about this device

    K Number
    K253366

    Validate with FDA (Live)

    Device Name
    LOGIQ Fortis
    Date Cleared
    2026-01-07

    (99 days)

    Product Code
    Regulation Number
    892.1550
    Age Range
    23 - 83
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K232381 LOGIQ Totus Diagnostic Ultrasound System, K231301 Vscan Air, K201768 Voluson E10, K220882 Vivid

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    LOGIQ Fortis is intended for use by a qualified physician for ultrasound evaluation of Fetal/Obstetrics; Abdominal (including Renal, Gynecology/Pelvic); Pediatric; Small Organ (Breast, Testes, Thyroid); Neonatal Cephalic; Adult Cephalic; Cardiac (Adult and Pediatric); Peripheral Vascular; Musculo-skeletal Conventional and Superficial; Urology (including Prostate); Transrectal; Transvaginal; Transesophageal and Intraoperative (Abdominal and Vascular).

    Modes of operation include: B, M, PW Doppler, CW Doppler, Color Doppler, Color M Doppler, Power Doppler, Harmonic Imaging, Coded Pulse, 3D/4D Imaging mode, Elastography, Shear Wave Elastography, Attenuation Imaging and Combined modes: B/M, B/Color, B/PWD, B/Color/PWD, B/Power/PWD.

    The LOGIQ Fortis is intended to be used in a hospital or medical clinic.

    Device Description

    The LOGIQ Fortis is a full featured, Track 3, general purpose diagnostic ultrasound system which consists of a mobile console approximately 575 mm wide (keyboard), 925 mm deep and 1300 mm high that provides digital acquisition, processing and display capability. The user interface includes a digital keyboard (physical keyboard as an option), specialized controls, 12-inch high-resolution color touch screen and 23.8-inch High Contrast LED LCD monitor (or 23.8-inch High Resolution LED LCD monitor as an option).

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study details for the AI features of the LOGIQ Fortis Ultrasound System, based on the provided FDA 510(k) clearance letter:

    AI Features Analyzed:

    1. Auto Abdominal Color Assistant 2.0
    2. Auto Aorta Measure Assistant
    3. Auto Common Bile Duct (CBD) Measure Assistant
    4. Ultrasound Guided Fat Fraction (UGFF)

    1. Auto Abdominal Color Assistant 2.0

    1.1. Acceptance Criteria and Reported Device Performance:

    Acceptance Criteria (Expected)Reported Device Performance (Achieved)
    Detection accuracy $\ge$ 80% (0.80)Accuracy: 94.8%
    Sensitivity (True Positive Rate): $\ge$ 80% (0.80)Sensitivity: 0.91
    Specificity (True Negative Rate): $\ge$ 80% (0.80)Specificity: 0.98
    DICE Similarity Coefficient (Segmentation Accuracy): $\ge$ 0.80 (for Aorta, Kidney, Liver/Spleen/IVC, GB/Urinary Bladder, Pancreas, Air view)DICE score: 0.82

    1.2. Sample Size and Data Provenance (Test Set):

    • Number of individual subjects: 49
    • Number of annotation images: 1186
    • Country: USA (100%)
    • Retrospective/Prospective: Not explicitly stated, but the description "Before the process of data annotation, all information displayed on the device is removed and performed on information extracted purely from Ultrasound B-mode images" and "Readers to ground truth the 'anatomy' visible in static B-Mode image" suggests retrospective analysis of collected images.

    1.3. Number and Qualifications of Experts for Ground Truth (Test Set):

    • Number of Experts: Not specified ("Readers to ground truth the 'anatomy'").
    • Qualifications: Not specified (generally, these would be qualified ultrasonographers or radiologists).

    1.4. Adjudication Method (Test Set): Not specified.

    1.5. MRMC Comparative Effectiveness Study: No, this study evaluates the standalone performance of the AI model.

    1.6. Standalone Performance: Yes, this study was done to evaluate the algorithm's performance in detecting abdominal structures.

    1.7. Type of Ground Truth Used: Expert consensus on "anatomy" visible in static B-Mode images.

    1.8. Sample Size for Training Set: Not explicitly stated, but implied to be separate from the test set.

    1.9. How Ground Truth for Training Set Was Established: Not explicitly stated, but implied to be similar to the test set, with experts annotating B-mode images.


    2. Auto Aorta Measure Assistant

    2.1. Acceptance Criteria and Reported Device Performance:

    Acceptance Criteria (Expected)Reported Device Performance (Achieved)
    Long View Aorta Keystrokes Reduction (AI vs. Manual): Not explicitly stated as a numerical criterion.Average keystrokes: 4.132 $\pm$ 0.291 (without AI) vs. 1.236 $\pm$ 0.340 (with AI)
    Short View Aorta Keystrokes Reduction (AI vs. Manual): Not explicitly stated as a numerical criterion.Average keystrokes: 7.05 $\pm$ 0.158 (without AI) vs. 2.307 $\pm$ 1.0678 (with AI)
    Long View AP Measurement Accuracy: Not explicitly stated as a numerical criterion.Average accuracy: 87.2% (95% CI +/- 1.98%)Average absolute error: 0.253 cm (95% CI 0.049 cm)Limits of Agreement: (-0.15, 0.60) cm (95% CI (-0.26, 0.71) cm)
    Short View AP Measurement Accuracy: Not explicitly stated as a numerical criterion.Average accuracy: 92.9% (95% CI +/- 2.02%)Average absolute error: 0.128 cm (95% CI 0.037 cm)Limits of Agreement: (-0.21, 0.36) cm (95% CI (-0.29, 0.45) cm)
    Short View Trans Measurement Accuracy: Not explicitly stated as a numerical criterion.Average accuracy: 86.9% (95% CI +/- 6.25%)Average absolute error: 0.235 cm (95% CI 0.110 cm)Limits of Agreement: (-0.86, 0.69) cm (95% CI (-1.06, 0.92) cm)

    2.2. Sample Size and Data Provenance (Test Set):

    • Long View Aorta:
      • Subjects: 36 (11 Male, 25 Female)
      • Country: 16 Japan, 20 USA
    • Short View Aorta:
      • Subjects: 35 (11 Male, 24 Female)
      • Country: 15 Japan, 20 USA
    • Retrospective/Prospective: Not explicitly stated, but "Validation images were collected on LOGIQ Fortis" and the truthing process suggests retrospective analysis of collected images.

    2.3. Number and Qualifications of Experts for Ground Truth (Test Set):

    • Number of Experts: Not specified ("Readers to ground truth...").
    • Qualifications: Not specified.

    2.4. Adjudication Method (Test Set): An "arbitrator to select most accurate measurement among all readers" was used. This suggests a form of adjudication, possibly 2+1 or similar, where the arbitrator acts as the tie-breaker/final decision-maker.

    2.5. MRMC Comparative Effectiveness Study: Yes, this study directly compares human performance with and without AI assistance by measuring keystrokes and accuracy.

    • Effect Size (Keystrokes):
      • Long View Aorta: Reduction of ~2.896 keystrokes (4.132 - 1.236)
      • Short View Aorta: Reduction of ~4.743 keystrokes (7.05 - 2.307)
        (While not a traditional effect size like AUC improvement, this quantifies human workflow improvement).

    2.6. Standalone Performance: Partially. The accuracy measurements compare AI baseline against an arbitrator's selected measurement, indicating standalone algorithm accuracy, but the primary focus is on human-in-the-loop efficiency.

    2.7. Type of Ground Truth Used: Expert consensus on measurements, with an arbitrator for final selection.

    2.8. Sample Size for Training Set: Not explicitly stated, but independence from the test set is ensured by "exam site origin."

    2.9. How Ground Truth for Training Set Was Established: Not explicitly stated, but implied to be similar to the test set, with experts performing measurements.


    3. Auto Common Bile Duct (CBD) Measure Assistant

    3.1. Acceptance Criteria and Reported Device Performance:

    Acceptance Criteria (Expected)Reported Device Performance (Achieved)
    Keystrokes Reduction (AI vs. Manual): Not explicitly stated as a numerical criterion.Average reduction: 1.62 $\pm$ 0.375
    Porta Hepatis measurement accuracy without segmentation scroll edit: Not explicitly stated as a numerical criterion.Average accuracy: 59.85% (95% CI +/- 17.86%)Average absolute error: 1.66 mm (95% CI 1.02 mm)Limits of Agreement: (-4.75, 4.37) mm (95% CI (-6.17, 5.79) mm)
    Porta Hepatis measurement accuracy with segmentation scroll edit: Not explicitly stated as a numerical criterion.Average accuracy: 80.56% (95% CI +/- 8.83%)Average absolute error: 0.91 mm (95% CI 0.45 mm)Limits of Agreement: (-1.96, 3.25) mm (95% CI (-2.85, 4.14) mm)

    3.2. Sample Size and Data Provenance (Test Set):

    • Subjects: 25 (11 Male, 14 Female)
    • Countries: USA (40%), Japan (60%)
    • Retrospective/Prospective: Not explicitly stated, but "Validation images were collected on LOGIQ Fortis" and the truthing process suggests retrospective analysis of collected images.

    3.3. Number and Qualifications of Experts for Ground Truth (Test Set):

    • Number of Experts: Not specified ("Readers to ground truth...").
    • Qualifications: Not specified.

    3.4. Adjudication Method (Test Set): An "arbitrator to select most accurate measurement among all readers" was used.

    3.5. MRMC Comparative Effectiveness Study: Yes, this study directly compares human performance with and without AI assistance by measuring keystrokes and accuracy (specifically, accuracy with and without segmentation scroll edit, which implies human interaction with AI).

    • Effect Size (Keystrokes): Average reduction of 1.62 keystrokes.

    3.6. Standalone Performance: Partially. The measurement accuracy with and without segmentation scroll edit provides insight into the algorithm's performance and the benefit of human refinement, but the primary focus is on human-in-the-loop efficiency and accuracy.

    3.7. Type of Ground Truth Used: Expert consensus on measurements, with an arbitrator for final selection.

    3.8. Sample Size for Training Set: Not explicitly stated, but independence from the test set is ensured by "exam site origin."

    3.9. How Ground Truth for Training Set Was Established: Not explicitly stated, but implied to be similar to the test set, with experts performing measurements.


    4. Ultrasound Guided Fat Fraction (UGFF)

    4.1. Acceptance Criteria and Reported Device Performance:

    Acceptance Criteria (Expected)Reported Device Performance (Achieved)
    Correlation with MRI-PDFF (Primary Study - Japan): Not explicitly stated as a numerical criterion.Correlation coefficient: 0.87 (strong correlation)
    Bland-Altman LOA with MRI-PDFF (Primary Study - Japan): Not explicitly stated.Offset: -0.32%LOA: -6.0% to 5.4%91.6% patients had differences smaller than the LOA (within $\pm$8.4%)
    Correlation with MRI-PDFF (Confirmatory Study - US/EU): Not explicitly stated as a numerical criterion.Correlation coefficient: 0.90 (strong correlation)
    Bland-Altman LOA with MRI-PDFF (Confirmatory Study - US/EU): Not explicitly stated.Offset: -0.1%LOA: -3.6% to 3.4%95.0% patients had differences smaller than the LOA (within $\pm$4.6%)
    Correlation with UDFF (Siemens) (Confirmatory Study - EU): Not explicitly stated as a numerical criterion.Correlation coefficient: 0.88 (strong correlation)
    Bland-Altman LOA with UDFF (Siemens) (Confirmatory Study - EU): Not explicitly stated.Offset: -1.2%LOA: -5.0% to 2.6%100% patients had differences smaller than the LOA (within $\pm$4.7%)

    4.2. Sample Size and Data Provenance (Test Set): This section describes the clinical studies used for validation of the UGFF index, rather than a traditional AI test set.

    • Primary Study (Development/Validation of UGFF Index):

      • Subjects: 582 participants
      • Country: Japan
      • Retrospective/Prospective: "external clinical study in Japan" implies prospective data collection, with subsequent analysis.
    • Second Confirmatory Study:

      • Subjects: 15 US patients, 5 EU patients (Total 20)
      • Country: US and EU
      • Retrospective/Prospective: Not specified.
    • Third Confirmatory Study (Comparison with Predicate):

      • Subjects: 24 EU patients
      • Country: EU
      • Retrospective/Prospective: Not specified.

    4.3. Number and Qualifications of Experts for Ground Truth (Test Set):

    • UGFF Study: The ground truth is established by a reference imaging modality (MRI-PDFF) and a comparison device (UDFF), not directly by human experts interpreting ultrasound images for the purpose of the study. The study involves acoustic property measurements.

    4.4. Adjudication Method (Test Set): Not applicable, as the ground truth is based on MRI-PDFF and UDFF, not human interpretation requiring adjudication.

    4.5. MRMC Comparative Effectiveness Study: No, this is a clinical validation against a reference standard and a comparative study against a predicate device.

    4.6. Standalone Performance: Yes, the UGFF index is an algorithm-generated value based on acoustic properties, and its performance is evaluated in a standalone manner against established reference methods (MRI-PDFF) and a legally marketed predicate (UDFF).

    4.7. Type of Ground Truth Used: Quantitative measurements from a reference imaging modality (MRI Proton Density Fat Fraction - MRI-PDFF %) and a comparative device (Ultrasound-Derived Fat Fraction (UDFF, Siemens)).

    4.8. Sample Size for Training Set: The UGFF index is based on a least squares fit (estimation) between acoustic property measurements and MRI-PDFF measurements from the primary 582-subject study. This study effectively serves as the "training" dataset for establishing the correlation and the estimation model.

    4.9. How Ground Truth for Training Set Was Established: MRI-PDFF measurements were obtained from the liver of these 582 participants.


    Ask a Question

    Ask a specific question about this device

    K Number
    K251963

    Validate with FDA (Live)

    Device Name
    LOGIQ E10s
    Date Cleared
    2025-10-29

    (125 days)

    Product Code
    Regulation Number
    892.1550
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K232381, K231301, K201768, K220882, K183575

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The LOGIQ E10s is intended for use by a qualified physician for ultrasound evaluation.

    Specific clinical applications and exam types include: Fetal / Obstetrics; Abdominal (including Renal, Gynecology / Pelvic); Pediatric; Small Organ (Breast, Testes, Thyroid); Neonatal Cephalic; Adult Cephalic; Cardiac (Adult and Pediatric); Peripheral Vascular; Musculo-skeletal Conventional and Superficial; Urology (including Prostate); Transrectal; Transvaginal; Transesophageal and Intraoperative (Abdominal and Vascular).

    Modes of operation include: B, M, PW Doppler, CW Doppler, Color Doppler, Color M Doppler, Power Doppler, Harmonic Imaging, Coded Pulse, 3D/4D Imaging mode, Elastography, Shear Wave Elastography, Attenuation Imaging and Combined modes: B/M, B/Color, B/PWD, B/Color/PWD, B/Power/PWD.

    The LOGIQ E10s is intended to be used in a hospital or medical clinic.

    Device Description

    The LOGIQ E10s is a full featured, Track 3, general purpose diagnostic ultrasound system which consists of a mobile console approximately 585 mm wide (keyboard), 991 mm deep and 1300 mm high that provides digital acquisition, processing and display capability. The user interface includes a computer keyboard, specialized controls, 12-inch high-resolution color touch screen and 23.8-inch High Contrast LED LCD monitor.

    AI/ML Overview

    The provided text describes three AI features: Auto Abdominal Color Assistant 2.0, Auto Aorta Measure Assistant, and Auto Common Bile Duct (CBD) Measure Assistant, along with a UGFF Clinical Study.

    Here's an analysis of the acceptance criteria and study details for each, where available:

    1. Table of Acceptance Criteria and Reported Device Performance

    For Auto Abdominal Color Assistant 2.0

    Acceptance CriteriaReported Device PerformanceMeets Criteria?
    Overall model detection accuracy (sensitivity and specificity): $\ge 80%$ (0.80)Accuracy: 94.8%Yes
    Sensitivity (True Positive Rate): $\ge 80%$ (0.80)Sensitivity: 0.91Yes
    Specificity (True Negative Rate): $\ge 80%$ (0.80)Specificity: 0.98Yes
    DICE Similarity Coefficient (Segmentation Accuracy): $\ge 0.80$DICE score: 0.82Yes

    For Auto Aorta Measure Assistant

    Acceptance CriteriaReported Device PerformanceMeets Criteria?
    No explicit numerical acceptance criteria were provided for keystrokes or measurement accuracy. The study aims to demonstrate improvement in keystrokes and acceptable accuracy. The provided results are the performance reported without specific targets for acceptance.Long View Aorta:- Average keystrokes: 4.132 (without AI) vs. 1.236 (with AI)- Average accuracy: 87.2% with 95% CI of +/- 1.98%- Average absolute error: 0.253 cm with 95% CI of 0.049 cm- Limits of Agreement: (-0.15, 0.60) with 95% CI of (-0.26, 0.71)Short View AP Measurement:- Average accuracy: 92.9% with 95% CI of +/- 2.02%- Average absolute error: 0.128 cm with 95% CI of 0.037 cm- Limits of Agreement: (-0.21, 0.36) with 95% CI of (-0.29, 0.45)Short View Trans Measurement:- Average accuracy: 86.9% with 95% CI of +/- 6.25%- Average absolute error: 0.235 cm with 95% CI of 0.110 cm- Limits of Agreement: (-0.86, 0.69) with 95% CI (-1.06, 0.92)N/A

    For Auto Common Bile Duct (CBD) Measure Assistant

    Acceptance CriteriaReported Device PerformanceMeets Criteria?
    No explicit numerical acceptance criteria were provided for keystrokes or measurement accuracy. The study aims to demonstrate reduction in keystrokes and acceptable accuracy. The provided results are the performance reported without specific targets for acceptance.- Average reduction in keystrokes (manual vs. AI): 1.62 +/- 0.375Keystrokes for Porta Hepatis measurement with segmentation scroll edit- Average accuracy: 80.56% with 95% CI of +/- 8.83%- Average absolute error: 0.91 mm with 95% CI of 0.45 mm- Limits of Agreement: (-1.96, 3.25) with 95% CI of (-2.85, 4.14)Porta Hepatis measurement accuracy without segmentation scroll edit- Average accuracy: 59.85% with 95% CI of +/- 17.86%- Average absolute error: 1.66 mm with 95% CI of 1.02 mm- Limits of Agreement: (-4.75, 4.37) with 95% CI of (-6.17, 5.79)N/A

    For UGFF Clinical Study

    Acceptance Criteria (Implied by intent to demonstrate strong correlation)Reported Device PerformanceMeets Criteria?
    Strong correlation between UFF values and MRI-PDFF (e.g., correlation coefficient $\ge 0.8$)Original study: Correlation coefficient = 0.87Confirmatory study (US/EU): Correlation coefficient = 0.90(Confirmatory study (UGFF vs UDFF): Correlation coefficient = 0.88)Yes
    Acceptable Limits of Agreement with MRI-PDFF (e.g., small offset and LOA with high percentage of patients within LOA)Original study: Offset = -0.32%, LOA = -6.0% to 5.4%, 91.6% patients within LOAConfirmatory study (US/EU): Offset = -0.1%, LOA = -3.6% to 3.4%, 95.0% patients within LOAYes
    No statistically significant effect of BMI, SCD, and other demographic confounders on AC, BSC, and SNR measurements (Implied)The results of the clinical study indicate that BMI, SCD, and other demographic confounders do not have a statistically significant effect on measurements of the AC, BSC, and SNR.Yes

    2. Sample size used for the test set and the data provenance

    Auto Abdominal Color Assistant 2.0:

    • Sample Size: 49 individual subjects (1186 annotation images)
    • Data Provenance: Retrospective, from the USA (100%).

    Auto Aorta Measure Assistant:

    • Sample Size:
      • Long View Aorta: 36 subjects
      • Short View Aorta: 35 subjects
    • Data Provenance: Retrospective, from Japan and USA.

    Auto Common Bile Duct (CBD) Measure Assistant:

    • Sample Size: 25 subjects
    • Data Provenance: Retrospective, from USA (40%) and Japan (60%).

    UGFF Clinical Study:

    • Sample Size:
      • Original study: 582 participants
      • Confirmatory study (US/EU): 15 US patients and 5 EU patients (total 20)
      • Confirmatory study (UGFF vs UDFF): 24 EU patients
    • Data Provenance: Retrospective and Prospective implicitly (clinical study implies data collection).
      • Original Study: Japan (Asian population)
      • Confirmatory Study (US/EU): US and EU (demographic info unavailable for EU patients, US patients: BMI 21.0-37.5, SCD 13.9-26.9)
      • Confirmatory Study (UGFF vs UDFF): EU

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Auto Abdominal Color Assistant 2.0:

    • Number of Experts: Not specified. The text mentions "Readers to ground truth the 'anatomy'".
    • Qualifications of Experts: Not specified.

    Auto Aorta Measure Assistant:

    • Number of Experts: Not specified. The text mentions "Readers to ground truth the AP measurement..." and an "Arbitrator to select most accurate measurement among all readers." This implies multiple readers and a single arbitrator.
    • Qualifications of Experts: Not specified.

    Auto Common Bile Duct (CBD) Measure Assistant:

    • Number of Experts: Not specified. The text mentions "Readers to ground truth the diameter..." and an "Arbitrator to select most accurate measurement among all readers." This implies multiple readers and a single arbitrator.
    • Qualifications of Experts: Not specified.

    UGFF Clinical Study:

    • Number of Experts: Not applicable, as ground truth was established by MRI-PDFF measurements, not expert consensus on images.

    4. Adjudication method for the test set

    Auto Abdominal Color Assistant 2.0:

    • Adjudication Method: Not explicitly described as a specific method (e.g., 2+1). The process mentions "Readers to ground truth" and then comparison to AI predictions, but no specific adjudication among multiple readers' initial ground truths.

    Auto Aorta Measure Assistant:

    • Adjudication Method: Implies an arbitrator-based method. "Arbitrator to select most accurate measurement among all readers." This suggests multiple readers provide measurements, and a single arbitrator makes the final ground truth selection.

    Auto Common Bile Duct (CBD) Measure Assistant:

    • Adjudication Method: Implies an arbitrator-based method. "Arbitrator to select most accurate measurement among all readers." Similar to the Aorta assistant.

    UGFF Clinical Study:

    • Adjudication Method: Not applicable. Ground truth was established by MRI-PDFF measurements.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Auto Abdominal Color Assistant 2.0:

    • MRMC Study: Not explicitly stated as a comparative effectiveness study showing human improvement. The study focuses on the algorithm's performance against ground truth.
    • Effect Size (Human Improvement with AI): Not reported.

    Auto Aorta Measure Assistant:

    • MRMC Study: Yes, an implicit MRMC study comparing human performance with and without AI. Readers performed measurements with and without AI assistance.
    • Effect Size (Human Improvement with AI):
      • Long View Aorta (Keystrokes): Average keystrokes reduced from 4.132 (without AI) to 1.236 (with AI).
      • Short View Aorta (Keystrokes): Average keystrokes reduced from 7.05 (without AI) to 2.307 (with AI).
      • (No specific improvement in diagnostic accuracy for human readers with AI is stated, primarily focuses on efficiency via keystrokes).

    Auto Common Bile Duct (CBD) Measure Assistant:

    • MRMC Study: Yes, an implicit MRMC study comparing human performance with and without AI. Readers performed measurements with and without AI assistance.
    • Effect Size (Human Improvement with AI):
      • Porta Hepatis CBD (Keystrokes): Average reduction in keystrokes for measurements with AI vs. manually is 1.62 +/- 0.375.
      • (No specific improvement in diagnostic accuracy for human readers with AI is stated, primarily focuses on efficiency via keystrokes).

    UGFF Clinical Study:

    • MRMC Study: No, this was a standalone algorithm performance study compared to a reference standard (MRI-PDFF) and a predicate device (UDFF). It did not involve human readers using the AI tool.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Auto Abdominal Color Assistant 2.0:

    • Standalone Performance: Yes. The reported accuracy, sensitivity, specificity, and DICE score are for the algorithm's performance.

    Auto Aorta Measure Assistant:

    • Standalone Performance: Yes, implicitly. The "AI baseline measurement" was compared for accuracy against the arbitrator-selected ground truth. While keystrokes involved human interaction to use the AI, the measurement accuracy is an algorithm output.

    Auto Common Bile Duct (CBD) Measure Assistant:

    • Standalone Performance: Yes, implicitly. The "AI baseline measurement" was compared for accuracy against the arbitrator-selected ground truth.

    UGFF Clinical Study:

    • Standalone Performance: Yes. The study directly assesses the correlation and agreement of the UGFF algorithm's output with MRI-PDFF and another ultrasound-derived fat fraction algorithm.

    7. The type of ground truth used

    Auto Abdominal Color Assistant 2.0:

    • Ground Truth Type: Expert consensus for anatomical visibility ("Readers to ground truth the 'anatomy' visible in static B-Mode image.")

    Auto Aorta Measure Assistant:

    • Ground Truth Type: Expert consensus from multiple readers, adjudicated by an arbitrator, for specific measurements ("Arbitrator to select most accurate measurement among all readers.")

    Auto Common Bile Duct (CBD) Measure Assistant:

    • Ground Truth Type: Expert consensus from multiple readers, adjudicated by an arbitrator, for specific measurements ("Arbitrator to select most accurate measurement among all readers.")

    UGFF Clinical Study:

    • Ground Truth Type: Outcomes data / Quantitative Reference Standard: MRI Proton Density Fat Fraction (MRI-PDFF %).

    8. The sample size for the training set

    Auto Abdominal Color Assistant 2.0:

    • Training Set Sample Size: Not specified beyond "The exams used for test/training validation purpose are separated from the ones used during training process".

    Auto Aorta Measure Assistant:

    • Training Set Sample Size: Not specified beyond "The exams used for regulatory validation purpose are separated from the ones used during model development process".

    Auto Common Bile Duct (CBD) Measure Assistant:

    • Training Set Sample Size: Not specified beyond "The exams used for regulatory validation purpose are separated from the ones used during model development process".

    UGFF Clinical Study:

    • Training Set Sample Size: Not specified. The study describes validation but not the training phase.

    9. How the ground truth for the training set was established

    Auto Abdominal Color Assistant 2.0:

    • Training Set Ground Truth: Not explicitly detailed, but implied to be similar to the test set ground truthing process: "Information extracted purely from Ultrasound B-mode images" and "Readers to ground truth the 'anatomy'".

    Auto Aorta Measure Assistant:

    • Training Set Ground Truth: Not explicitly detailed, but implied to be similar to the test set ground truthing process: "Information extracted purely from Ultrasound B-mode images" and "Readers to ground truth the AP measurement...".

    Auto Common Bile Duct (CBD) Measure Assistant:

    • Training Set Ground Truth: Not explicitly detailed, but implied to be similar to the test set ground truthing process: "Information extracted purely from Ultrasound B-mode images" and "Readers to ground truth the diameter...".

    UGFF Clinical Study:

    • Training Set Ground Truth: Not specified for the training set, but for the validation set, the ground truth was MRI-PDFF measurements.
    Ask a Question

    Ask a specific question about this device

    K Number
    K243226

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-05-08

    (212 days)

    Product Code
    Regulation Number
    892.1550
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K231301

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Ultrasound Imaging System is a software-based imaging system and accessories intended for use by qualified physicians and healthcare professionals who has the ability to conduct ultrasound scan process for evaluation by ultrasound imaging system or fluid flow analysis of the human body. The modes of operation include B mode, M mode, PWD mode, Color Doppler (CD) mode, Power Doppler mode, and the combined mode (B+M, B+CD, B+PWD). Specific clinical applications and exam types including:

    LX Series:
    Ophthalmic,Fetal,General abdominal imaging,Pediatric,Small organ (Nerve, prostate, scrotum, breast),Neonatal cephalic,Trans-rectal,Trans-vaginal,Urology,Musculoskeletal (conventional),Musculoskeletal (superficial),OB/Gyn,Cardiac (adult),Cardiac (pediatric),Peripheral vessel ,Other (Carotid),Pulmonary,Nerve

    128 Series:
    Ophthalmic,Fetal,General abdominal imaging,Pediatric,Small organ (Nerve, prostate, scrotum, breast),Neonatal cephalic,Trans-rectal,Trans-vaginal,Urology,Musculoskeletal (conventional),Musculoskeletal (superficial),OB/Gyn,Cardiac (adult),Cardiac (pediatric),Peripheral vessel ,Other (Carotid),Pulmonary,interventional guidance (free hand needle/ catheter),FAST/EFAST,Nerve

    LU700 Series:
    Ophthalmic,Fetal,General abdominal imaging,Pediatric,Small organ (Nerve, prostate, scrotum, breast),Neonatal cephalic,Trans-rectal,Trans-vaginal,Urology,Musculoskeletal (conventional),Musculoskeletal (superficial),OB/Gyn,Cardiac (adult),Cardiac (pediatric),Peripheral vessel ,Other (Carotid),Pulmonary,interventional guidance (free hand needle/ catheter),FAST/EFAST,Nerve

    The device is intended for use in environments where healthcare is provided by trained healthcare professionals, but not intended for use in emergency medical service, ambulance, or aircraft.

    Device Description

    The Ultrasound Imaging System is a portable, software controlled, handheld ultrasound system used to acquire and display hi-resolution, real-time ultrasound data through a commercial off-the-shelf (COTS) mobile device.

    I. The imaging system software runs as an app on a mobile device.

    II. The imaging system software can be download to a commercial off-the-shelf (COTS) mobile device and utilizes an icon touch-based user interface.

    III. The imaging system consists of a series of wireless transducers employing Wi-Fi-based technology to communicate with traditional tablet/smartphone devices via direct Wi-Fi. This allows the user to export ultrasound images and display them across a range portable personal device.

    IV. The imaging system houses a built-in battery, multichannel beamformer, prescan converter and Wi-Fi components

    A complete list of all the probes and indications including:

    Dual headed probe

    LX Series:

    LX128LC
    Linear transducer: Ophthalmic,General abdominal imaging,Pediatric,Small organ (thyroid, prostate, scrotum, breast),Neonatal cephalic,Musculoskeletal (conventional),Musculoskeletal (superficial),Peripheral vessel ,Other (Carotid),Pulmonary,interventional guidance (free hand needle/ catheter),Nerve

    Convex transducer: Fetal,General abdominal imaging,Pediatric,Small organ (thyroid, prostate, scrotum, breast),Urology,Musculoskeletal (conventional),OB/Gyn,Cardiac (adult),Cardiac (pediatric),Peripheral vessel ,interventional guidance (free hand needle/ catheter),FAST/EFAST,Nerve

    LX128LP
    Linear transducer: Ophthalmic,General abdominal imaging,Pediatric,Small organ (thyroid, prostate, scrotum, breast),Neonatal cephalic,Musculoskeletal (conventional),Musculoskeletal (superficial),Peripheral vessel ,Other (Carotid),Pulmonary,interventional guidance (free hand needle/ catheter),Nerve

    Phased Array transducer: ,Fetal,General abdominal imaging,Pediatric,Cardiac (adult),Cardiac (pediatric),Pulmonary,FAST/EFAST,Nerve

    LX192LC
    Linear transducer: Ophthalmic,General abdominal imaging,Pediatric,Small organ (thyroid, prostate, scrotum, breast),Neonatal cephalic,Musculoskeletal (conventional),Musculoskeletal (superf-dotorial),Peripheral vessel ,Other (Carotid),Pulmonary,interventional guidance (free hand needle/ catheter),Nerve

    Convex transducer: ,Fetal,General abdominal imaging,Pediatric,Small organ (thyroid, prostate, scrotum, breast),Urology,Musculoskeletal (conventional),OB/Gyn,Cardiac (adult),Cardiac (pediatric),Peripheral vessel ,interventional guidance (free hand needle/ catheter),FAST/EFAST,Nerve

    Single headed probe

    128 Series:

    LK128C
    Fetal,General abdominal imaging,Pediatric,Small organ (thyroid, prostate, scrotum, breast),Urology,Musculoskeletal (conventional),OB/Gyn,Cardiac (adult),Cardiac (pediatric),Peripheral vessel ,interventional guidance (free hand needle/ catheter),FAST/EFAST,Nerve

    LK128L
    Ophthalmic,General abdominal imaging,Pediatric,Small organ (thyroid, prostate, scrotum, breast),Neonatal cephalic,Musculoskeletal (conventional),Musculoskeletal (superficial),Peripheral vessel ,Other (Carotid),Pulmonary,interventional guidance (free hand needle/ catheter),Nerve

    LK128LH
    Ophthalmic,General abdominal imaging,Pediatric,Small organ (thyroid, prostate, scrotum, breast),Neonatal cephalic,Musculoskeletal (conventional),Musculoskeletal (superficial),Peripheral vessel ,Other (Carotid),Pulmonary,interventional guidance (free hand needle/ catheter),Nerve

    LK128M
    Fetal,General abdominal imaging,Pediatric,Small organ (thyroid, prostate, scrotum, breast),Neonatal cephalic,Urology,Musculoskeletal (conventional),OB/Gyn,Cardiac (adult),Cardiac (pediatric),Peripheral vessel ,interventional guidance (free hand needle/ catheter)

    LK128PA
    Fetal,General abdominal imaging,Pediatric,Cardiac (adult),Cardiac (pediatric),Pulmonary,FAST/EFAST,Nerve

    LK128E
    Fetal,General abdominal imaging,Pediatric,Small organ (thyroid, prostate, scrotum, breast),Trans-rectal,Trans-vaginal,Urology,OB/Gyn,interventional guidance (free hand needle/ catheter)

    LU700 Series:

    LU700L
    General abdominal imaging,Pediatric,Small organ (thyroid, prostate, scrotum, breast),Neonatal cephalic,Musculoskeletal (conventional),Musculoskeletal (superficial),Peripheral vessel ,Other (Carotid),Pulmonary,interventional guidance (free hand needle/ catheter),Nerve

    LU710L
    Ophthalmic,General abdominal imaging,Pediatric,Small organ (thyroid, prostate, scrotum, breast),Neonatal cephalic,Musculoskeletal (conventional),Musculoskeletal (superficial),Peripheral vessel ,Other (Carotid),Pulmonary,interventional guidance (free hand needle/ catheter),Nerve

    LU710LH
    Ophthalmic,General abdominal imaging,Pediatric,Small organ (thyroid, prostate, scrotum, breast),Neonatal cephalic,Musculoskeletal (conventional),Musculoskeletal (superficial),Peripheral vessel ,Other (Carotid),Pulmonary,interventional guidance (free hand needle/ catheter),Nerve

    LU700C
    General abdominal imaging,Musculoskeletal (conventional),Musculoskeletal (superficial),OB/Gyn,Peripheral vessel ,interventional guidance (free hand needle/ catheter),FAST/EFAST,Nerve

    LU710C
    Fetal,General abdominal imaging,Pediatric,Small organ (thyroid, prostate, scrotum, breast),Urology,Musculoskeletal (conventional),OB/Gyn,Cardiac (adult),Cardiac (pediatric),Peripheral vessel ,interventional guidance (free hand needle/ catheter),FAST/EFAST,Nerve

    LU710M
    Fetal,General abdominal imaging,Pediatric,Small organ (thyroid, prostate, scrotum, breast),Neonatal cephalic,Urology,Musculoskeletal (conventional),OB/Gyn,Cardiac (adult),Cardiac (pediatric),Peripheral vessel ,interventional guidance (free hand needle/ catheter)

    LU710PA
    Fetal,General abdominal imaging,Pediatric,Cardiac (adult),Cardiac (pediatric),Pulmonary,FAST/EFAST,Nerve

    LU710E
    Fetal,General abdominal imaging,Pediatric,Small organ (thyroid, prostate, scrotum, breast),Trans-rectal,Trans-vaginal,Urology,OB/Gyn,interventional guidance (free hand needle/ catheter)

    AI/ML Overview

    The provided FDA 510(k) clearance letter and summary for Leltek Inc.'s Ultrasound Imaging Systems (K243226) address the addition of new dual-headed probes (LX series) to existing cleared devices. While it asserts that the new models meet safety and performance standards, the document does not provide specific acceptance criteria or detailed study results for device performance in the format requested.

    The document primarily focuses on demonstrating substantial equivalence to a predicate device (K241161) and compliance with various recognized standards (e.g., IEC 60601 series, ISO 10993 series). It states that "No additional clinical testing is required" due to the nature of the changes being additions of transducers with established technologies.

    Therefore, the requested information cannot be fully extracted directly from this document. However, I can reconstruct what parts are mentioned or implied.

    Here's a breakdown of what can be inferred or directly stated from the provided text, and what is missing:


    Request for Acceptance Criteria and Study Details

    The provided document (FDA 510(k) Clearance Letter - Leltek Inc. Ultrasound Imaging Systems, K243226) details a submission for adding new dual-headed probes (LX series) to an already cleared Ultrasound Imaging System. It asserts that the new models meet safety and performance standards equivalent to the predicate device, thereby requiring no additional clinical testing.

    The document does not provide specific acceptance criteria or detailed study results for device performance in the format of a comparative table or a comprehensive study description as requested for a new AI/software-based medical device. Instead, it relies on the principle of substantial equivalence and compliance with recognized standards for hardware modifications.

    However, it does provide information on the safety and performance evaluations conducted to support the substantial equivalence.


    Requested Information Breakdown:

    1. Table of Acceptance Criteria and Reported Device Performance

    Not explicitly provided as clear, quantifiable acceptance criteria or reported device performance metrics in the given document.
    The document states that the devices comply with various standards, which inherently means they meet the performance requirements within those standards. It mentions:

    • "full compliance with acoustic output, biocompatibility, cleaning, and disinfection effectiveness"
    • "maximum acoustic output level is under the FDA recommended limit"
    • "All the safety and performance tests of the device meet the essential requirements."

    Without specific numerical targets for metrics like accuracy, sensitivity, or specificity (which are common for AI/software devices, but not the primary focus here for a hardware add-on to an imaging system), a table cannot be constructed. The performance is assessed against the established safety and performance of the predicate device and relevant industry standards.

    2. Sample size used for the test set and the data provenance

    Not applicable in the context of this 510(k) submission for new transducers.
    The submission focuses on the safety and performance of the hardware (new transducers) and their integration with existing software. It explicitly states, "No additional clinical testing is required." Therefore, there is no mention of a clinical "test set" with patient data or its provenance. The testing would be on the physical device's characteristics (e.g., acoustic output, EMC, biocompatibility).

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. As no clinical "test set" or diagnostic performance study is described, there's no mention of experts establishing ground truth for such a test.

    4. Adjudication method for the test set

    Not applicable. As no clinical "test set" or diagnostic performance study is described, there's no mention of an adjudication method.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    No. This is not an AI/Software as a Medical Device (SaMD) submission focused on aiding diagnosis, but rather a submission for a new hardware component (ultrasound transducers) to an imaging system. Therefore, no MRMC study or AI assistance effect size is mentioned.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done

    No. This is not an AI/SaMD submission.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    Not applicable. For this type of submission, the "ground truth" for demonstrating safety and performance relates to engineering specifications, physical measurements (e.g., acoustic output, electrical safety), and material properties (e.g., biocompatibility testing results), rather than clinical diagnostic accuracy against pathology or expert consensus.

    8. The sample size for the training set

    Not applicable. This submission is for hardware. There is no mention of a "training set" in the context of an algorithm or AI.

    9. How the ground truth for the training set was established

    Not applicable. As there is no training set mentioned, this information is not available.


    Summary of Device Safety and Performance Assessment (from the Document):

    The document indicates that the substantial equivalence is established based on the following:

    • Compliance with recognized standards: A comprehensive list of IEC and ISO standards for medical electrical equipment, usability, software lifecycle, biological evaluation (biocompatibility), risk management, and quality management is provided (Pages 14-15).
    • Acoustic Output: The device is tested and determined to be in "full compliance with acoustic output" and the "maximum acoustic output level is under the FDA recommended limit" (Page 16).
    • Biocompatibility: The new models are deemed to have "biosafety equivalence" and passed "biocompatibility" tests (Page 16).
    • Cleaning and Disinfection: Demonstrated "cleaning, and disinfection effectiveness" (Page 16).
    • Software and Hardware Equivalence: The new LX Series probes "utilizes the same software, cover material, and transducer specifications as the 128 Series but replaces a similar PCBA with a dual-headed probe, maintaining the same block diagram." (Page 16)
    • No Pragmatic Detriments: The changes "have no pragmatic detriments" (Page 16).

    In essence, Leltek Inc. demonstrated that the new LX series transducers behave similarly to their predicate devices and comply with relevant safety standards, thus no further clinical performance studies were deemed necessary for this specific 510(k) submission.

    Ask a Question

    Ask a specific question about this device

    K Number
    K242168

    Validate with FDA (Live)

    Date Cleared
    2024-12-20

    (149 days)

    Product Code
    Regulation Number
    892.1550
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K231301 Vscan Air, K211488 Logiq E10, K240111: Venue

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The device is a general purpose ultrasound system intended for use by qualified and trained healthcare professionals. Specific clinical applications remain the same as previously cleared: Fetall OB; Abdominal (including GYN, pelvic and infertility monitoring/follicle development); Pediatric; Small Organ (breast, testes, thyroid etc.); Neonatal and Adult Cephalic; Cardiac (adult and pediatric); Musculo-skeletal Conventional and Superficial; Vascular; Transvaginal (including GYN); Transrectal

    Modes of operation include: B, M, PW Doppler, CW Doppler, Color Doppler, Color M Doppler, Power Doppler, Harmonic Imaging, Coded Pulse, 3D/4D Imaging mode, Elastography, Shear Wave Elastography and Combined modes: B/M, B/Color, B/PWD, B/Color/PWD, B/Power/ PWD, B/ Elastography. The Voluson™ Expert 18, Voluson™ Expert 20, Voluson™ Expert 22 is intended to be used in a hospital or medical clinic.

    Device Description

    The systems are full-featured Track 3 ultrasound systems, primarily for general radiology use and specialized for OB/GYN with particular features for real-time 3D/4D acquisition. They consist of a mobile console with keyboard control panel; color LCD/TFT touch panel, color video display and optional image storage and printing devices. They provide high performance ultrasound imaging and analysis and have comprehensive networking and DICOM capability. They utilize a variety of linear, curved linear, matrix phased array transducers including mechanical and electronic scanning transducers, which provide highly accurate real-time three-dimensional imaging supporting all standard acquisition modes.

    AI/ML Overview

    The provided document describes the predicate devices as the Voluson Expert 18, Voluson Expert 20, Voluson Expert 22. The K-number for the primary predicate device is K231965. The document does NOT describe the acceptance criteria or study that proves the device meets the acceptance criteria for those predicate devices. Instead, it details the testing and acceptance criteria for new or updated AI software features introduced with the new Voluson Expert Series devices (K242168).

    Here's a breakdown of the requested information based on the AI testing summaries provided for the new/updated features: Sono Pelvic Floor 3.0 (MHD and Anal Sphincter), SonoAVC Follicle 2.0, and 1st/2nd Trimester SonoLyst/SonoLystlive.


    Acceptance Criteria and Device Performance for New/Updated AI Features

    1. Table of Acceptance Criteria and Reported Device Performance

    AI FeatureAcceptance CriteriaReported Device Performance
    Sono Pelvic Floor 3.0 (MHD)MHD Tracking, Minimum MHD Frame Detection, Maximum MHD Frame Detection:- On datasets marked as "Good Image Quality": success rate should be 70% or higher.- On datasets marked as "Challenging Image Quality": success rate should be 60% or higher. Overall MHD:- On "Good IQ" datasets: 70% or higher. - On "Challenging Quality" datasets: 60% or higher.MHD Tracking:- Good Image Quality: 89.3%- Challenging Image Quality: 77.7%Minimum MHD Frame Detection:- Good Image Quality: 89.3%- Challenging Image Quality: 83.3%Maximum MHD Frame Detection:- Good Image Quality: 90.66%- Challenging Image Quality: 77.7%Overall MHD:- On Good IQ datasets: 81.9%- On Challenging quality datasets: 60.9%
    Sono Pelvic Floor 3.0 (Anal Sphincter)- On datasets marked as "Good Image Quality": success rate should be 70% or higher.- On datasets marked as "Challenging Image Quality": success rate should be 60% or higher.The document states "Verification results on actual verification data is as follows" but then the table structure is missing the actual performance metrics for Anal Sphincter. It only lists "On Good IQ datasets: 81.9%" and "On Challenging quality datasets: 60.9%" under the MHD section, implying those might be overall success rates for the entire Sono Pelvic Floor 3.0 feature across both components, but it's not explicitly clear. Therefore, the specific reported device performance for "Anal Sphincter" is not clearly presented in the provided text.
    SonoAVC Follicle 2.0- The success rate for the AI feature should be 70% or higher. (This appears to be an overall accuracy criterion).Accuracy:- On test data acquired together with train cohort: 94.73%- On test data acquired consecutively post model development: 92.8%- Overall Accuracy: 93.6%Dice Coefficient by Size Range:- 3-5 mm: 0.937619- 5-10 mm: 0.946289- 10-15 mm: 0.962315- >15 mm: 0.93206
    1st Trimester SonoLyst/SonoLystLive- The average success rate of SonoLyst 1st Trimester IR, X and SonoBiometry CRL and overall traffic light accuracy is 80% or higher.The document states "The average success rate...is 80% or higher" as the acceptance criteria and then mentions "Data used for both training and validation has been collected across multiple geographical sites..." but it does not explicitly provide the numerically reported device performance value that met or exceeded the 80% criterion.
    2nd Trimester SonoLyst/SonoLystLive- Acceptance criteria are met for both subgroups (variety of ultrasound systems/data formats vs. target platform). (The specific numerical criteria for acceptance are not explicitly stated, but rather that the performance met them for demonstration of generalization.)The document states "For both subgroups the acceptance criteria are met." but does not explicitly provide the numerically reported device performance values.

    2. Sample Sizes Used for the Test Set and Data Provenance

    • Sono Pelvic Floor 3.0 (MHD & Anal Sphincter):

      • Test Set Sample Size: 93 volumes for MHD, 106 volumes for Anal Sphincter.
      • Data Provenance: Data is provided by external clinical partners who de-identified the data. Original data collected in 4D volume Cines (*.vol5 or *.4dv6) or 4D/3D volume acquisitions (*.vol2 or *.4dv3).
      • Countries: A diverse range of countries contributed to the test data including Italy, U.S.A, Australia, Germany, Czech Republic, France, India (for MHD); and Italy, U.S.A, France, Germany, India (for Anal Sphincter).
      • Retrospective/Prospective: The data collection method ("re-process data to our needs retrospectively during scan conversion") suggests a retrospective approach to assembling the dataset, although a "standardized data collection protocol was followed for all acquisitions." New data was also acquired post-model development from previously unseen sites to test robustness.
    • SonoAVC Follicle 2.0:

      • Test Set Sample Size: 138 datasets, with a total follicle count of 2708 across all volumes.
      • Data Provenance: External clinical partners provided de-identified data in 3D volumes (*.vol or *.4dv).
      • Countries: Germany, India, Spain, United Kingdom, USA.
      • Retrospective/Prospective: The data was split into train/validation/test at the start of model development (suggesting retrospective). Additionally, consecutive data was acquired post-model development from previously unseen systems and probes to test robustness (suggesting some prospective element for this later test set).
    • 2nd Trimester SonoLyst/SonoLystLive:

      • Test Set Sample Size: "Total number of images: 2.2M", "Total number of cine loops: 3595". It's not explicitly stated how much of this was test data vs. training data, but it implies a large dataset for evaluation.
      • Data Provenance: Systems used for data collection included GEHC Voluson V730, E6, E8, E10, Siemens S2000, and Hitachi Aloka. Formats included DICOM & JPEG for still images and RAW data for cine loops.
      • Countries: UK, Austria, India, and USA.
      • Retrospective/Prospective: Not explicitly stated, but "All training data is independent from the test data at a patient level" implies a pre-existing dataset split rather than newly acquired prospective data solely for testing.
    • 1st Trimester SonoLyst/SonoLystLive:

      • Test Set Sample Size: SonoLyst 1st Trim IR: 5271 images, SonoLyst 1st Trim X: 2400 images, SonoLyst 1st Trim Live: 6000 images, SonoBiometry CRL: 110 images.
      • Data Provenance: Systems included GE Voluson V730, P8, S6/S8, E6, E8, E10, Expert 22, Philips Epiq 7G. Formats included DICOM & JPEG for still images and RAW data for cine loops.
      • Countries: UK, Austria, India, and USA.
      • Retrospective/Prospective: "All training data is independent from the test data at a patient level." "A statistically significant subset of the test data is independent from the training data at a site level, with no test data collected at the site being used in training." This indicates a retrospective collection with careful splitting, and some test data from unseen sites.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    • Sono Pelvic Floor 3.0 (MHD & Anal Sphincter), SonoAVC Follicle 2.0, 2nd Trimester SonoLyst/SonoLystLive, 1st Trimester SonoLyst/SonoLystLive:

      • Number of Experts: Three independent reviewers.
      • Qualifications: "at least two being US Certified sonographers, with extensive clinical experience."
    • Additional for 2nd Trimester SonoLyst/SonoLystLive & 1st Trimester SonoLyst/SonoLystLive:

      • For sorting/grading accuracy review, a "5-sonographer review panel" was used. Qualifications are not specified beyond being sonographers.

    4. Adjudication Method for the Test Set

    • Sono Pelvic Floor 3.0 (MHD & Anal Sphincter), SonoAVC Follicle 2.0, 2nd Trimester SonoLyst/SonoLystLive, 1st Trimester SonoLyst/SonoLystLive:
      • The evaluation was "based on interpretation of the AI output by reviewing clinicians." The evaluation was "conducted by three independent reviewers."
      • For 2nd and 1st Trimester SonoLyst/SonoLystLive, where sorting/grading accuracy was determined, if initial sorting/grading differed from the ground truth (established by a single sonographer then refined), a 5-sonographer review panel was used, and reclassification was based upon the "majority view of the panel." This implies a form of majority vote adjudication for these specific sub-tasks.
      • The general approach for the three reviewers, especially when evaluating AI output, implies an independent review, and while not explicitly stated, differences would likely lead to discussion or a form of consensus/adjudication. However, a strict 'X+Y' model (like 2+1 or 3+1) is not explicitly detailed.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and Effect Size

    • The document does not describe a multi-reader multi-case (MRMC) comparative effectiveness study designed to measure how human readers improve with AI vs. without AI assistance. The studies described are primarily aimed at assessing the standalone performance or workflow utility of the AI features.

    6. If a Standalone (i.e., Algorithm Only Without Human-in-the-Loop Performance) Was Done

    • Yes, standalone performance was assessed for all described AI features. The "Summary test Statistics" and "Verification Results" sections for each feature (Sono Pelvic Floor 3.0, SonoAVC Follicle 2.0, 1st/2nd Trimester SonoLyst/SonoLystLive) report the algorithm's direct performance (e.g., success rates, accuracy, Dice coefficient) against the established ground truth, indicating standalone evaluation. The "interpretation of the AI output by reviewing clinicians" method primarily focuses on validating the AI's direct result rather than a comparative human performance study.

    7. The Type of Ground Truth Used

    • Expert Consensus/Annotation:
      • Sono Pelvic Floor 3.0 (MHD): Ground truth was established through a "two-stage curation process." Curators identified the MHD plane and marked anatomical structures. These curated datasets were then "reviewed by expert arbitrators."
      • Sono Pelvic Floor 3.0 (Anal Sphincter): Ground truth involved "3D segmentation of the Anal Canal using VOCAL tool in the 4D View5 Software." Each volume was "reviewed by a skilled arbitrator for correctness."
      • SonoAVC Follicle 2.0: The "Truthing process for training dataset" indicates a "detailed curation protocol (developed by clinical experts)" and a "two-step approach" with an arbitrator reviewing all datasets for clinical accuracy.
      • 2nd Trimester SonoLyst/SonoLystLive & 1st Trimester SonoLyst/SonoLystLive: Ground truth for sorting/grading was initially done by a single sonographer, then reviewed by a "5-sonographer review panel" for accuracy, with reclassification based on majority view if needed.

    8. The Sample Size for the Training Set

    • Sono Pelvic Floor 3.0 (MHD): Total Volumes: 983
    • Sono Pelvic Floor 3.0 (Anal Sphincter): Total Volumes: 828
    • SonoAVC Follicle 2.0: Total Volumes: 249
    • 2nd Trimester SonoLyst/SonoLystLive: "Total number of images: 2.2M", "Total number of cine loops: 3595". (The precise breakdown of training vs. test from this total isn't given for this feature, but it's a large overall dataset).
    • 1st Trimester SonoLyst/SonoLystLive: 122,711 labelled source images from 35,861 patients.

    9. How the Ground Truth for the Training Set Was Established

    • Sono Pelvic Floor 3.0 (MHD): A two-stage curation process. First, curators identify the MHD plane and then mark anatomical structures. These curated datasets are then reviewed by expert arbitrators and "changes/edits made if necessary to maintain correctness and consistency in curations."
    • Sono Pelvic Floor 3.0 (Anal Sphincter): "3D segmentation of the Anal Canal using VOCAL tool in the 4D View5 Software." Curation protocol involved aligning the volume and segmenting the Anal Canal. Each volume was "reviewed by a skilled arbitrator for correctness."
    • SonoAVC Follicle 2.0: A "two-step approach" was followed. First, curators were trained on a "detailed curation protocol (developed by clinical experts)." Second, an automated quality control step confirmed mask/marking availability, and an arbitrator reviewed all datasets from each curator's completed data pool for clinical accuracy, with inconsistencies discussed by the curation team.
    • 2nd Trimester SonoLyst/SonoLystLive & 1st Trimester SonoLyst/SonoLystLive: The images were initially "curated (sorted and graded) by a single sonographer." If these differed from the ground truth (which implies a higher standard or previous ground truth for comparison), a "5-sonographer review panel" reviewed them and reclassified based on majority view to achieve the final ground truth.
    Ask a Question

    Ask a specific question about this device

    K Number
    K240206

    Validate with FDA (Live)

    Device Name
    Venue Sprint
    Date Cleared
    2024-06-10

    (137 days)

    Product Code
    Regulation Number
    892.1550
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K231301, K170714, K202035, K203137, K200851

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Venue Sprint is a general-purpose diagnostic ultrasound system for use by qualified and trained healthcare professionals or practitioners that are legally authorized or licensed by law in the country. state or other local municipality in which he or she practices, for ultrasound imaging, measurement. display and analysis of the human body and fluid. The users may or may not be working under supervision or authority of a physician. Users may also include medical students working under the supervision or authority of a physician during their education / training.

    The Venue Sprint is intended to be used in a hospital, medical clinic, home environment and road/air ambulance.

    Venue Sprint clinical applications include: abdominal (GYN and Urology), thoracic/pleural, ophthalmic, Fetal/OB, Small Organ (including breast, testes, thyroid), Vascular/Peripheral vascular, neonatal and adult cephalic, pediatric, musculoskeletal (conventional and superficial), cardiac (adults and pediatric, 40 kg and above) and interventional guidance (includes free hand tissue biopsy, fluid drainage, vascular access). Modes of operation include: B. M. PW Doppler, Color Doppler and Harmonic Imaging.

    Device Description

    Venue Sprint is a general-purpose diagnostic ultrasound system intended for use by qualified and trained healthcare professionals to evaluate the body by ultrasound imaging and fluid flow analysis. The Venue Sprint is used together with the Vscan Air probes and provides the user interface for control of the probes and the needed software functionality for analysis of the ultrasound images and saving/storage of the related images and videos.

    AI/ML Overview

    This document describes the Venue Sprint diagnostic ultrasound system (K240206). Based on the provided text, the device is an ultrasound system and does not appear to have AI/ML functionality that requires specific performance metrics beyond general safety and effectiveness. The document explicitly states that clinical studies were not required to support substantial equivalence.

    Therefore, most of the requested information regarding acceptance criteria, specific performance tables, sample sizes, expert ground truth, MRMC studies, or standalone algorithm performance is not present in this 510(k) summary for the Venue Sprint.

    Here's an attempt to answer the questions based only on the provided text:

    1. A table of acceptance criteria and the reported device performance

    The provided document does not contain a specific table of acceptance criteria or performance metrics for an AI/ML component. The "acceptance criteria" for this device appear to be compliance with various safety and performance standards for diagnostic ultrasound systems.

    Acceptance Criteria CategoryReported Device Performance Summary (from document)
    Acoustic OutputComplies with applicable medical device safety standards.
    BiocompatibilityComplies with applicable medical device safety standards; Transducer material is biocompatible.
    Cleaning and Disinfection EffectivenessComplies with applicable medical device safety standards.
    Thermal, Electrical, Electromagnetic, and Mechanical SafetyComplies with applicable medical device safety standards.
    Voluntary Standards ComplianceComplies with: - Marketing Clearance of Diagnostic Ultrasound Systems and Transducers - Guidance- AAMI/ANSI ES60601-1- IEC 60601-1-2- IEC 60601-2-37- IEC 62359- ISO 10993-1- ISO 14971- NEMA PS 3.1-3.20e (DICOM)- AAMI TIR69- IEC 60601-1-11- IEC 60601-1-12
    Quality Assurance MeasuresRisk Analysis, Requirements Reviews, Design Reviews, Testing (unit, integration, performance, safety)

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document explicitly states: "The subject of this premarket submission, Venue Sprint, did not require clinical studies to support substantial equivalence." Therefore, there is no mention of a test set, its sample size, or data provenance from clinical studies within this submission.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    Not applicable, as no clinical studies requiring ground truth establishment for a test set were conducted or described.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable, as no clinical studies requiring ground truth establishment for a test set were conducted or described.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. The document does not describe any AI-assisted features or MRMC studies. The device is described as a "general-purpose diagnostic ultrasound system." The phrase "expanding cleared Auto Inferior Vena Cava (IVC), Auto B-Lines, Real Time ejection fraction (RT-EF) and cNerve" refers to features already cleared on other predicate devices and their expansion to new probes on this system; it does not constitute a new AI feature with its own performance study described here.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable, as no standalone algorithm performance study is described.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    Not applicable, as no clinical studies requiring ground truth were conducted or described.

    8. The sample size for the training set

    Not applicable, as no machine learning model training is described in this submission.

    9. How the ground truth for the training set was established

    Not applicable, as no machine learning model training is described in this submission.

    Ask a Question

    Ask a specific question about this device

    K Number
    K234106

    Validate with FDA (Live)

    Device Name
    Venue Fit
    Date Cleared
    2024-06-10

    (167 days)

    Product Code
    Regulation Number
    892.1550
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    Why did this record match?
    Reference Devices :

    K231301 Vscan Air, K161047 LOGIQ P9 and LOGIQ P7, K231989 LOGIQ E10s/LOGIQ Fortis, K180374 Voluson S8

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Venue Fit is a general purpose diagnostic ultrasound system for use by qualified and trained healthcare professionals or practitioners that are legally authorized or licensed by law in the country, state or other local municipality in which he or she practices, for ultrasound imaging, measurement, display and analysis of the human body and fluid. The users may or may not be working under supervision or authority of a physician. Users may also include medical students working under the supervision or authority of a physician during their education / training. Venue Fit is intended to be used in a hospital or medical clinic. Venue Fit clinical applications include: abdominal (GYN and Urology), thoracic/pleural, ophthalmic, Fetal/OB, Small Organ (including breast, testes, thyroid), Vascular/Peripheral vascular, neonatal and adult cephalic, pediatric, musculoskeletal (conventional and superficial), cardiac (adults and pediatric), Transrectal, Transvaginal, Transesophageal, Intraoperative (vascular) and interventional guidance (includes tissue biopsy, fluid drainage, vascular and non-vascular access). Modes of operation include: B, M, PW Doppler, CW Doppler, Color M Doppler, Color M Doppler, Harmonic Imaging, Coded Pulse and Combined modes: B/M, B/Color M, B/PWD, B/Color/PWD, B/Power/PWD, B/CWD. B/Color/CWD.

    Device Description

    The Venue Fit is a general purpose diagnostic ultrasound system. It is a portable system with a touch screen interface. It can be powered through an electrical wall outlet or an internal battery. It utilizes linear, convex, and phased array transducers and supports standard acquisition modes. Compatible biopsy kits can be used for needle-guidance procedures. The system can display the patient's ECG trace synchronized to the scanned image. A barcode reader and RFID scanner are available as additional input devices. A roller bag is available for transport. It is capable of wired or wireless internet connection and meets DICOM requirements for image storage and archiving.

    AI/ML Overview

    The provided text describes specific features and functionalities of the GE Venue Fit ultrasound system but does not contain information about acceptance criteria, reported device performance, or a specific study proving it meets acceptance criteria as typically outlined for AI/CADe devices.

    The document is a 510(k) Premarket Notification Submission for the Venue Fit ultrasound system. It primarily focuses on demonstrating substantial equivalence to a predicate device (K220848 Venue Fit) regarding general imaging capabilities, technological characteristics, safety, and effectiveness.

    Here's what can be extracted and what is explicitly stated as not applicable:

    1. A table of acceptance criteria and the reported device performance
    Not provided in the document. The document focuses on performance testing in the context of safety and effectiveness, rather than specific diagnostic accuracy metrics.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)
    Not applicable. The document states, "The subject of this premarket submission, Venue Fit, did not require clinical studies to support substantial equivalence." Therefore, there is no test set in the context of a clinical study for diagnostic performance.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)
    Not applicable, as no clinical studies were required.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set
    Not applicable, as no clinical studies were required.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
    Not applicable. This document does not describe an AI/CADe device that assists human readers, nor does it present results from an MRMC study.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
    Not applicable. The Venue Fit is a diagnostic ultrasound system, not a standalone algorithm. Its capabilities, like "Auto Volume Flow (AVF)" or "Bladder Volume Tool", are functionalities of the ultrasound system itself, not standalone AI algorithms with reported diagnostic performance metrics.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)
    Not applicable, as no clinical studies requiring ground truth establishment were mentioned.

    8. The sample size for the training set
    Not applicable. The document does not describe a machine learning algorithm that would have a training set. The "Venue Fit" is a general-purpose diagnostic ultrasound system. While it has "semi-automated tools," the document does not detail their development or any AI-specific training sets.

    9. How the ground truth for the training set was established
    Not applicable, as there is no mention of a training set for an AI algorithm.


    Summary of what is present:

    The document establishes substantial equivalence through a comparison to a predicate device (K220848 Venue Fit) and a list of reference devices (K231301 Vscan Air, K161047 LOGIQ P9 and LOGIQ P7, K231989 LOGIQ E10s/LOGIQ Fortis, K180374 Voluson S8/ S10/ S10 Expert, K202035 Vscan Air).

    It outlines several non-clinical tests performed to ensure safety and compliance with standards:

    • Acoustic output evaluation
    • Biocompatibility
    • Cleaning and disinfection effectiveness
    • Thermal, electrical, electromagnetic, and mechanical safety

    The system states compliance with various voluntary standards including:

    • Marketing Clearance of Diagnostic Ultrasound Systems and Transducers - Guidance for Industry and Food and Drug Administration Staff (February 21, 2023)
    • AAMI/ANSI ES60601-1 (Medical Electrical Equipment - Part 1: General Requirements for Safety)
    • IEC 60601-1-2 (Electromagnetic Compatibility Requirements and Tests)
    • IEC 60601-2-37 (Particular Requirements for the Safety of Ultrasonic Medical Diagnostic and Monitoring Equipment)
    • IEC 62359 (Ultrasonics Field characterization Test methods for the determination of thermal and mechanical indices related to medical diagnostic ultrasonic fields)
    • ISO 10993-1 (Biological Evaluation of Medical Devices-Part 1: Evaluation and Testing Within a Risk Management Process)
    • ISO 14971 (Application of risk management to medical devices)
    • NEMA PS 3.1 3.20e (Digital Imaging and Communications in Medicine (DICOM) Set)
    • AAMI TIR69 (Technical Information Report Risk management of radio-frequency wireless coexistence for medical devices and systems)

    Quality assurance measures applied during development include:

    • Risk Analysis
    • Requirements Reviews
    • Design Reviews
    • Testing on unit level (Module verification)
    • Integration testing (System verification)
    • Performance testing (Verification & Validation)
    • Safety testing (Verification)

    The conclusion states that based on equipment design similarities, conformance to recognized performance standards, and performance testing, the proposed Venue Fit is considered substantially equivalent in safety, effectiveness, and performance to the predicate device.

    Crucially, the document explicitly states: "The subject of this premarket submission, Venue Fit, did not require clinical studies to support substantial equivalence." This means that the information requested regarding acceptance criteria, device performance, sample sizes, ground truth, experts, adjudication, and MRMC/standalone studies in a diagnostic performance context is not available within this document.

    Ask a Question

    Ask a specific question about this device

    K Number
    K240053

    Validate with FDA (Live)

    Device Name
    Venue Go
    Date Cleared
    2024-06-10

    (154 days)

    Product Code
    Regulation Number
    892.1550
    Age Range
    All
    Predicate For
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Venue Go is a general purpose diagnostic ultrasound system for use by qualified and trained healthcare professionals or practitioners that are legally authorized or licensed by law in the country, state or other local municipality in which he or she practices, for ultrasound imaging, measurement, display and analysis of the human body and fluid. The users may or may not be working under supervision or authority of a physician. Users may also include medical students working under the supervision or authority of a physician during their education / training. Venue Go is intended to be used in a hospital or medical clinic. Venue Go clinical applications include: abdominal (GYN and Urology), thoracic/pleural, ophthalmic, Fetal/OB, Small Organ (including breast, testes, thyroid), Vascular/Peripheral vascular, neonatal and adult cephalic, pediatric, musculoskeletal (conventional and superficial), cardiac (adults and pediatric), Transrectal, Transvaginal, Transesophageal, Intraoperative (vascular) and interventional guidance (includes tissue biopsy, fluid drainage, vascular and non-vascular access). Modes of operation include: B, M, PW Doppler, CW Doppler, Color Doppler, Color M Doppler, Power Doppler, Harmonic Imaging, Coded Pulse and Combined modes: B/M, B/Color M, B/PWD, B/Color/PWD, B/Power/PWD, B/CWD, B/Color/CWD.

    Device Description

    Venue Go is a general-purpose diagnostic ultrasound system intended for use by qualified and trained healthcare professionals to evaluate the body by ultrasound imaging and fluid flow analysis.

    The Venue Go is a compact, portable system with a small footprint. The system can be hand carried using an integrated handle, placed on a horizontal surface, attached to a mobile cart or wall mounted. It has a high resolution color LCD monitor, with a simple, multi-touch user interface that makes the system intuitive. The system can be powered through an electrical wall outlet for long term use or from an internal battery for a short time with full functionality and scanning.

    The Venue Go utilizes a variety of linear, convex, and phased array transducers which provide high imaging performance and support standard acquisition modes. Compatible biopsy kits can be used for needle-guidance procedures.

    The system is capable of displaying the patient's ECG trace synchronized to the scanned image. This allows the user to view an image from a specific time of the ECG signal which is used as an input for gating during scanning. The ECG signal can be input directly from the patient or as an output from an ECG monitoring device. ECG information is not intended for monitoring or diagnosis.

    A barcode reader and RFID scanner are available as additional input devices. A roller bag will also be available for the customer to use when transporting the system.
    Venue Go is capable of wireless communication through a built-in Wireless LAN device. The system meets DICOM requirements to support image storage and archiving (local PACS or products such as Q-Path) and allows for output to printing devices.

    AI/ML Overview

    The provided FDA 510(k) summary for the GE Venue Go ultrasound system does not include acceptance criteria for artificial intelligence (AI) performance or the study details to prove the device meets such criteria.

    The document primarily focuses on demonstrating substantial equivalence to a predicate device (Venue Go K220800) and other reference devices, based on:

    • Identical fundamental scientific technology.
    • Similar imaging capabilities, technological characteristics, safety, and effectiveness.
    • Minor updates to the Indications for Use statement for clarity regarding operator qualifications.
    • Addition of new transducers already cleared on other GE devices.
    • New features/functionality such as Auto Volume Flow (AVF), Bladder Volume Tool, expanded MSK diagrams, Venue Coach, electronic software delivery, expanded Auto Inferior Vena Cava (IVC), Auto B-Lines, Real-Time ejection fraction (RT-EF), cNerve for Vscan Air CL and SL probes (which are already cleared with these AI features on predicate Vscan Air K231301 and reference LOGIQ E10s/LOGIQ Fortis K231989), and AppAPI functionality.
    • Conformity to recognized performance standards for acoustic output, biocompatibility, cleaning/disinfection, thermal, electrical, electromagnetic, and mechanical safety.
    • Quality assurance measures like risk analysis, requirements/design reviews, and various levels of testing.

    Specifically, the document states: "The subject of this premarket submission, Venue Go, did not require clinical studies to support substantial equivalence." This indicates that any evaluation of "AI performance" as typically understood (e.g., using a test set with ground truth, performance metrics, and acceptance criteria) was not part of this 510(k) submission.

    The AI-related features mentioned (Auto IVC, Auto B-Lines, RT-EF, cNerve) are noted as being "expanded" or already "cleared" on predicate/reference devices (K231301 Vscan Air, K231989 LOGIQ E10s/LOGIQ Fortis). This implies their performance was likely evaluated as part of those previous 510(k) submissions, and the current submission is leveraging that prior clearance for their inclusion in the Venue Go system when used with the particular probes.

    Therefore, since this 510(k) does not present new AI performance study data for the Venue Go, I cannot extract the requested information. The document focuses on demonstrating that the Venue Go, with its included features, is substantially equivalent to existing cleared devices, rather than proving novel AI algorithm performance.

    Ask a Question

    Ask a specific question about this device

    K Number
    K240111

    Validate with FDA (Live)

    Device Name
    Venue
    Date Cleared
    2024-06-10

    (146 days)

    Product Code
    Regulation Number
    892.1550
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K231301 Vscan Air, K161047 LOGIQ P9 and LOGIQ P7, K231989 LOGIQ E10s/LOGIQ Fortis, K180374 Voluson S8

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Venue is a general purpose diagnostic ultrasound system for use by qualified and trained healthcare professionals or practitioners that are legally authorized or licensed by law in the country. state or other local municipality in which he or she practices, for ultrasound imaging, measurement. display and analysis of the human body and fluid. The users may or may not be working under supervision or authority of a physician. Users may also include medical students working under the supervision or authority of a physician during their education / training.

    Venue is intended to be used in a hospital or medical clinic. Venue clinical applications include: abdominal (GYN and Urology), thoracic/pleural, ophthalmic. Fetal/OB, Small Organ (including breast, testes, thyroid), Vascular/Peripheral vascular, neonatal and adult cephalic, pediatric, musculoskeletal (conventional and superficial), cardiac (adults and pediatric), Transrectal, Transvaginal, Transesophageal, Intraoperative (vascular) and interventional guidance (includes tissue biopsy, fluid drainage, vascular and non-vascular access). Modes of operation include: B. M. PW Doppler, CW Doppler, Color M Doppler, Color M Doppler, Harmonic Imaging, Coded Pulse and Combined modes: B/M, B/Color M, B/PWD, B/Color/PWD, B/Power/PWD,B/CWD, B/Color/CWD.

    Device Description

    The proposed Venue system is a general-purpose, Track 3, diagnostic ultrasound device, intended for ultrasound imaging, measurement and analysis of the human body and fluid that provides digital acquisition, processing and display capabilities. Venue can be used in offices, clinics and hospitals.

    The Venue is a mobile system with a small footprint that easily fits into tight spaces and positioned to accommodate the sometimes-awkward work settings of the point of care user.

    The Venue has a high resolution color LCD monitor, with a simple, multi-touch user interface that makes the system intuitive. The single surface screen provides easy cleanability. Articulated monitor arm enables flexible display positions in order to be accessible and clearly visible in both user-standing and sitting positions.

    The system is capable of displaying the patient's ECG trace synchronized to the scanned image. This allows the user to view an image from a specific time of the ECG signal which is used as an input for gating during scanning. The ECG signal can be input directly from the patient or as an output from an ECG monitoring device. ECG information is not intended for monitoring or diagnosis.

    Barcode reader and RFID scanner are available as additional input devices.

    The Venue has a battery that allows for scanning without the need to plug in to an electrical outlet.

    System meets DICOM requirements to support users image storage and archiving needs and allows for output to printing devices.

    The Venue utilizes a variety of linear, convex, and phased array transducers which provide high imaging capability, supporting all standard acquisition modes. Compatible biopsy kits can be used for needle-guidance procedures.

    The system includes several automated tools designed to simplify and shorten the workflow time of the healthcare professional for some common assessments.

    AI/ML Overview

    The provided document is a 510(k) Summary for a diagnostic ultrasound system (Venue). It does not contain information about acceptance criteria and a study that proves the device meets those criteria for software performance.

    The document states:

    • "The subject of this premarket submission, Venue, did not require clinical studies to support substantial equivalence." (Page 10)
    • The comparison is primarily focused on hardware, transducers, and general features, and states that the Venue system is substantially equivalent to a predicate device regarding "imaging capabilities, technological characteristics and safety and effectiveness." (Page 6)

    Therefore, I cannot extract the requested information regarding acceptance criteria, device performance, sample sizes, data provenance, expert qualifications, ground truth establishment, or multi-reader multi-case studies because this document does not present such a study. The submission focuses on demonstrating substantial equivalence to a predicate device, which often relies on non-clinical tests and comparisons rather than new clinical performance studies.

    Ask a Question

    Ask a specific question about this device

    K Number
    K232285

    Validate with FDA (Live)

    Device Name
    U-Lite PRO
    Manufacturer
    Date Cleared
    2024-01-11

    (164 days)

    Product Code
    Regulation Number
    892.1550
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K171164, K202856, K231301

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    U-Lite PRO is a Handheld Ultrasound system intended for use in environments where healthcare is provided by qualified and trained healthcare professionals.

    It can therefore be used in different configurations, especially:

    • In medical offices (general practitioner's office)
    • In clinics & hospitals (incl. in emergency and critical care units)
    • In a field hospital

    It is used in imaging or examinations rooms.

    It can be used at the bedside. It is not intended for direct use in a sterile environment.

    The U-Lite PRO is not compatible with the use of the HF surgery device or in an MRI system.

    U-Lite PRO is indicated for the visualization of structures and dynamic processes in the human body using ultrasound imaging and fluid flow analysis for diagnosis in the following clinical applications:

    • ophthalmic
    • fetal/obstetric,
    • gynecological,
    • abdominal,
    • pediatric,
    • neonatal cephalic
    • adult cephalic
    • small organ,
    • trans-vaginal,
    • trans-rectal,
    • cardiac adult & pediatric
    • peripheral vascular,
    • urology (including prostate)
    • musculoskeletal (both conventional and superficial)

    Note : The application fields are dependent on the selected probes and the modes of operations.

    Modes of operations include:

    • B-Mode (B)
    • M-Mode (M)
    • Color Doppler (CD)
    • Power Doppler (PD)
    • Spectral Pulsed-Wave Doppler (PWD)
    • Continous Wave Doppler (CWD)
    • Combined :(B+M; B+CD; B+ PD; B+PWD)
    Device Description

    U-Lite PRO is a compact, ultralight battery powered general purpose diagnostic ultrasound scanner. The U-Lite PRO is a notebook-size, battery-operated, generalpurpose track 3 diagnostic ultrasound system. The U-Lite PRO can be handheld measuring 180mm x 115mm x 20mm and weighing 0.7 kg (approximately 1.54 lbs.). The unit is a handheld ultrasound (HHU) imaging system with interchangeable probes with optional stand.

    The U-Lite PRO is used to acquire and display high-resolution LED screen images, realtime ultrasound data and display the data as B Mode, M Mode, PWD Mode, CWD Mode, Color Doppler Mode, Power Doppler, Tissue Harmonic Imaging Mode, and Combined (B +M; B+CD; B+PD; B+PWD).

    AI/ML Overview

    The provided text is a 510(k) summary for the U-Lite PRO ultrasonic pulsed Doppler imaging system. It focuses on demonstrating substantial equivalence to predicate devices through technical comparisons and compliance with various standards, rather than providing detailed clinical study data with specific acceptance criteria and performance metrics for an AI/CADe (Computer-Aided Detection/Diagnosis) component.

    Therefore, the document does not contain the information required to populate a table of acceptance criteria for AI performance, nor does it describe a study proving an AI/CADe device meets such criteria. Specifically:

    • No acceptance criteria for AI were provided. The document describes acoustic output limits and measurement accuracy for the ultrasound system itself, but not for any AI/CADe features.
    • No specific study proving AI performance was described. The document states, "No clinical studies were conducted," and the "Non-clinical Performance Testing" sections focus on electrical safety, EMC, usability, biocompatibility, and software verification/validation, along with acoustic output and measurement range/accuracy of the ultrasound hardware. There is no mention of a study to assess the performance of an AI algorithm in detection, diagnosis, or reader assistance.

    Given the information provided in the document, it is not possible to complete the requested table or describe a study proving the device meets AI/CADe acceptance criteria, as the submission does not detail any AI component or its performance evaluation. The device described appears to be an ultrasound imaging device, not explicitly an AI/CADe system for image analysis.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1