510(k) Data Aggregation

    K Number
    K250280

    Validate with FDA (Live)

    Date Cleared
    2025-07-23

    (173 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The SD TL Implant System is indicated for use in partially or fully edentulous mandibles and maxillae, in support of single or multiple-unit restorations including; cemented retained, screw retained, or overdenture restorations, and terminal or intermediate abutment support for fixed bridgework. Abutments are indicated for screw-retained single restorations or cement-retained single of multi-unit restorations. SD TL Implant System is dedicated for two stage surgical procedures and for immediate loading when there is good primary stability and an appropriate occlusal load. All digitally-designed abutments are intended to be sent to an ARUM DENTISTRY validated milling center for manufacture.

    Device Description

    SD TL Implant System consist of below:
    Fixture

    • SD Tissue Level Fixture
    • SD Bone Level Fixture

    Abutment

    • Multi Angled Cylinder
    • Multi Digital Cylinder
    • Multi Ti Cylinder
    • Multi Healing Cap
    • Healing Abutment
    • Temporary Abutment
    1. Fixture
      This product is a dental implant which is placed into alveolar bone to replace the function of missing teeth. To enhance the osseointegration with the alveolar bone, this titanium dental implant is treated with SLA (Sandblasted with Large-grit and Acid-etching). As a dental implant which is placed into alveolar bone to support dental prostheses such as artificial teeth used to rehabilitate a patient's masticatory function, the product is used as a substructure implanted into the human body.

    An endosseous dental implant is a device made of a material as Pure Titanium (Conforming to ASTM F67) which will be placed in the alveolar bone to replace the function of the missing tooth. The SD TL Implant System consists of dental implants, abutments for use in one or two-stage dental implant placement and restorations.

    The implant-abutment connection is tight and precise fitting with non-submerged external connection and with submerged internal connection. The surface of the fixture is treated with SLA (Sandblasted with Large-grit and Acid-etching). It is only part to be implanted into bone, and to provide connection of prosthetic devices or other components of a dental implant set with human body (mandibular or maxillary bone).

    The dimension ranges of the subject device are below:

    1. SD Tissue Level Fixture: Ø 3.7, 4.2, 4.6, 5.0 (D) x 7.0, 8.5, 10.0, 11.5, 13.0 mm (L)
    2. SD Bone Level Fixture: Ø 6.48 (D) x 7.0, 8.5, 10.0, 11.5 mm (L)
    1. Abutment
      The abutment is made of Ti-6Al-4V Eli (Conforming to ASTM F136) to be used in fabricating patient-specific abutments. The subject devices are indicated for cemented or screw-and cement retained prosthesis (SCRP) restorations. Each patient-specific abutment is individually prescribed by the clinician. The Multi Angled cylinders come in engaging and non-engaging types.
    1. Multi Angled Cylinder: Ø 5.5 (D) x 9.5, 10.5 mm
    2. Multi Digital Cylinder: Ø 5.5 (D) x 6.5, 7.5, 8.5, 9.5 mm
    3. Multi Ti Cylinder: Ø 4.8 (D) x 4.5 mm, Ø 5.5 (D) x 8.0, 9.0 mm
    4. Multi Healing Cap: Ø 4.8, 5.7 (D) x 4.35, 5.85, 7.35 mm
    5. Healing Abutment: Ø 3.5, 3.67, 4.2, 5.2, 6.2, 7.5, 8.5 (D) x 6.9 ~ 13.3mm
    6. Temporary Abutment: Ø 3.7, 4.0 (D) x 10.4, 10.45, 12.4, 12.45 mm

    Tolerance of dimension shall be within ± 1% range.

    Multi Digital Cylinder and Multi Ti Cylinder are used as part of a two-piece abutment, where the base is premanufactured from titanium alloy (Ti-6Al-4V Eli) and the top half is a CAD/CAM zirconia superstructure, milled at a validated milling center. These pieces are cemented together to form the final abutment.

    The Titanium Base abutment is composed of two-piece abutment that is a titanium base at the bottom and a zirconia superstructure (CAD/CAM patient specific superstructure) at the top. The zirconia superstructure is straight only and is not to be designed to provide an angle or divergence correction.
    For the Multi Digital Cylinder and Multi Ti Cylinder the design parameters for the CAD/CAM zirconia superstructure are:

    • Minimum wall thickness – 0.5 mm;
    • Minimum post height for single-unit restorations – 4.5 mm;
    • Maximum gingival height – 5.0 mm;
    • Minimum gingival height – 0.5 mm;
    • Angulation - 0°
      *The post height is defined as measured above the gingival height of the final patient-matched design.

    The digital workflow requires the use of the following equipment:

    • Restorative Material: Non-Sterile Zirconia Block (K190112)
    • Dental Cement: U-Cem Premium & MAZIC Cem (K193260)

    The SD TL Implant System is compatible with the SD Bone Level Fixtures and NB Implant Systems. (as the below table).

    AI/ML Overview

    The provided FDA 510(k) Clearance Letter for the "SD TL Implant System" does not contain information about acceptance criteria or a study proving the device meets those criteria in the context typically seen for Artificial Intelligence (AI) or software as a medical device (SaMD) products.

    This document is for a physical medical device (dental implants and associated components), specifically an endosseous dental implant (Product Code: DZE, NHA; Regulation Number: 21 CFR 872.3640; Regulatory Class: Class II).

    The "performance data" section in this document describes:

    • Biocompatibility testing (ISO 10993-5, ISO 10993-12) to ensure the materials are safe for use in the human body.
    • Sterilization validation (ISO 11137-1, 11137-2, ANSI/AAMI ST79, ISO 17665-1, -2, ISO 11737-1,-2, ISO 11138-1, AAMI / ANSI ST72:2011/(R)2016) to ensure the device is sterile.
    • Shelf-life testing (ASTM F1980) to confirm stability over time.
    • Mechanical performance testing (ISO 14801) for static compression and compression fatigue, which are standard tests for the structural integrity of dental implants.
    • Scanning electron microscopy (SEM) and Energy dispersive X-ray spectroscopy (EDS) for surface characteristics.
    • MR environment condition review to assess safety in MRI environments.

    These tests are standard for a physical implantable device to demonstrate substantial equivalence to a predicate device. They are not related to AI/software performance criteria (like accuracy, sensitivity, specificity, AUC) or human reader study designs (like MRMC studies, ground truth establishment by experts, adjudication methods).

    Therefore, I cannot populate the requested table or answer the questions related to AI/software performance, ground truth, expert consensus, or MRMC studies, as this information is not present in the provided document.

    The document explicitly states: "Non-clinical testing data submitted, referenced or relied on in this submission support demonstrating substantial equivalence." and "The results of the above tests have met the criteria of the standards and demonstrated the substantial equivalence with the primary predicate." This refers to the physical and material properties, not AI algorithm performance.

    Ask a Question

    Ask a specific question about this device

    K Number
    K220079

    Validate with FDA (Live)

    Date Cleared
    2022-12-14

    (338 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K093321, K152520, K173120, K192197, K201981, K212517

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Magicore Narrow System (3.0, 3.5mm) may be used as an artificial root structure for single tooth replacement of mandibular central and lateral incisors and maxillary lateral incisors.
    The implants may be restored immediately

    1. with a temporary prosthesis that is not in functional occlusion,
    2. when splinted together as an artificial root structure for multiple tooth replacement of mandibular incisors, or
    3. for denture stabilization using multiple implants in the anterior mandible and maxilla.
      The implants may be placed in immediate function when good primary stability has been achieved and with appropriate occlusal loading.
    Device Description

    The Magicore Narrow System consists of dental implants, cylinders, caps and screws for use in one or two-stage dental implant placement and restorations. The implant-Abutment connection is tight and precise fitting with internal hex and Morse taper bevel. The surface of the Magicore Narrow implant is treated with RBM (Resorbable Blasted media) or SLA(sand-blasted, large-grit, acid-etched).

    AI/ML Overview

    This document is a 510(k) summary, which is a premarket submission made to FDA to demonstrate that the device to be marketed is at least as safe and effective as a legally marketed predicate device. For dental implants, substantial equivalency is typically demonstrated through engineering and material characteristic comparisons to predicate devices, and performance testing, rather than clinical studies with patient outcomes. Therefore, the questions typically associated with clinical studies (like sample size for test sets, number of experts for ground truth, MRMC studies, training set details, etc.) are not directly applicable in the context of this 510(k) summary.

    The manufacturer is demonstrating substantial equivalence by comparing the "Magicore Narrow System" to several predicate and reference devices. The acceptance criteria and the "study" proving the device meets these criteria are primarily based on comparative technical characteristics and non-clinical performance testing, rather than a clinical trial with human subjects.

    Here's a breakdown based on the provided document, addressing the closest equivalents to your questions:


    1. Table of Acceptance Criteria and Reported Device Performance

    The term "acceptance criteria" here refers to demonstrating that the new device's characteristics and performance are substantially equivalent to legally marketed predicate devices, meaning they do not raise new questions of safety or effectiveness. The performance is "reported" by showing that the subject device's features align with or are within acceptable ranges of the predicate devices, and by outlining non-clinical tests performed.

    Characteristic/Test AreaAcceptance Criteria (Implied by Predicate Equivalence)Reported Device Performance (Summary of Equivalence and Testing)
    Indications for UseMust be substantially equivalent to predicate devices to ensure similar intended clinical application.The Magicore Narrow System (3.0, 3.5mm) has identical indications for use as the primary predicate (s-Clean OneQ-SL Narrow Implant System, K161244) and a reference device (BioHorizons Laser-Lok 3.0 Implant System, K093321): used as an artificial root structure for single tooth replacement of mandibular central and lateral incisors and maxillary lateral incisors; immediate restoration with temporary prosthesis not in functional occlusion; splinted for multiple tooth replacement of mandibular incisors; or for denture stabilization using multiple implants in anterior mandible and maxilla. Implants may be placed in immediate function when good primary stability and appropriate occlusal loading are achieved.
    MaterialsMust use biocompatible materials that are commonly accepted for dental implants and are equivalent to predicate devices.Fixtures and most abutments are made of Ti-6Al-4V ELI (Conforming to ASTM Standard F-136), identical to predicate devices. The Magicore Solid Abutment Cap is made of PolyOxyMethylene (=Acetal).
    Design CharacteristicsFixture and abutment design characteristics (e.g., connection type, surface treatment, diameters, lengths) should be within a clinically acceptable range compared to predicate devices, or differences must be justified as not raising new safety/effectiveness concerns.Fixtures:- Inner Connection: Internal hex, non-submerged (similar to predicates).- Endosseous Implant: Tapered, macro threads (similar to predicates).- Platform Diameters: Ø 4.0.- Fixture Diameters: Ø 3.0, Ø 3.5 (similar to predicates, with Ø 3.3 for one predicate and Ø 3.0 for another).- Implantable Lengths: 11.0, 13.0, 15.0 mm (longer lengths supported by reference device K093321).- Modified Surface: RBM & SLA (Primary predicate K161244 uses SLA; reference device K093321 uses RBM. Differences justified).- Surgical Technique: 1 and 2 stage, self-tapping (similar to predicates).Abutments: Various abutments (Closing Screw, Short Abutment, Magic Abutment, Magicore Solid Abutment, Magicore Solid Abutment Cap, Magicore Healing Cap, Healing Cap Screw, Abutment Screw) are compared to various reference devices (K152520, K192197, K212517, K201981, K173120). Differences in dimensions (diameters, lengths) are noted but justified as not affecting fundamental functions or safety due to similarity in intended use, fundamental scientific technology, principle of operation, general design, technology, functions, and materials.
    SterilizationDevice must be sterile or sterilizable, and sterilization methods must be validated and equivalent to predicate devices.Fixtures are provided sterile via Gamma sterilization (similar to predicates). Closing Screw and Magicore Healing Cap also Gamma sterilized. Other abutments are provided non-sterile for end-user sterilization, with validation tested to ANSVAAMI ST79, ISO 17665-1/2, ISO 11737-1/2, ISO 11138-1 (leveraged from predicate K202479 and K140806).
    BiocompatibilityDevice materials must be biocompatible.Biocompatibility testing for fixtures (ISO 10993-1, 3, 5, 6, 10, 11) and abutments made of Titanium ELI (ISO 10993-1, 5, 6, 10) was leveraged from predicates (K140806 & K162099), demonstrating equivalence with same materials and manufacturing processes.
    Non-Clinical PerformanceMechanical and packaging integrity must be demonstrated as safe and effective.Shelf Life: Tested for subject fixtures according to ASTM F1980 (results met criteria).LAL Testing: Performed for subject fixtures according to USP <85> (referenced in K140806 & K162099, results met criteria).Surface Modification Analysis: Surface roughness, surface composition analysis, and SEM imaging compared between subject (RBM and SLA surfaces) and predicate devices (K152520 and K192197) to demonstrate substantial equivalence.MR Environment Condition: Non-clinical worst-case MRI review performed using scientific rationale and published literature, addressing magnetically induced displacement force and torque based on FDA guidance.Fixture Packaging Performance: Human Factors testing (usability evaluation for aseptic presentation per ISO 11607-1:2019 and FDA guidance), low and high magnification imaging after removal from packaging to check for damage, and Quality System plan for packaging acceptance activities were provided. Results indicated devices conform to product specifications with packaging design.

    2. Sample Size Used for the Test Set and Data Provenance

    This document is a 510(k) summary for a dental implant, which does not typically involve a "test set" or "training set" of patient data in the way an AI/ML device would. Instead, substantial equivalence is demonstrated through comparative engineering data and non-clinical performance testing.

    • Sample Size for Testing: The document refers to various standards (e.g., ASTM F1980, ISO 11137-1/2, USP <85>, ANSV/AAMI ST79 series, ISO 17665-1/2, ISO 11737-1/2, ISO 11138-1, ISO 10993 series) for non-clinical performance tests. The specific sample sizes for these engineering tests are not detailed in this summary but would be part of the full test reports. For example, biomechanical tests (fatigue, static strength) are typically conducted with small sample sizes (e.g., n=5 or n=10 per group, as per ISO standards for implants).
    • Data Provenance: The data comes from non-clinical laboratory testing performed by the manufacturer (InnoBioSurg Co., Ltd.) or leveraged from testing performed for predicate devices from other manufacturers. Data is implicitly prospective in the sense that the manufacturer conducted these tests for this specific submission or leveraged existing valid test data from similar devices. The country of origin for the non-clinical data is not specified but the manufacturer is based in the Republic of Korea.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Their Qualifications

    Not applicable. "Ground truth" in the context of clinical expert consensus for image-based diagnostic or prognostic devices is not relevant for this type of medical device (dental implant). Substantial equivalence is based on engineering and material standards, and comparison to already-cleared predicate devices. The "experts" would be the engineers and quality assurance professionals who conducted and reviewed the non-clinical tests.


    4. Adjudication Method for the Test Set

    Not applicable. There is no "adjudication method" in the sense of reconciling differences in expert annotations or diagnoses, as this is not a diagnostic device relying on human interpretation of complex data.


    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No. An MRMC comparative effectiveness study is not performed for dental implants. These studies are typically conducted for AI/ML-driven diagnostic or screening devices to assess how the AI assists human readers.


    6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) Was Done

    Not applicable. This is not an algorithm-based diagnostic device.


    7. The Type of Ground Truth Used

    The "ground truth" for this device's acceptance is based on:

    • Engineering Standards: Compliance with recognized international and national standards for medical devices and dental implants (e.g., ASTM, ISO standards for materials, sterilization, biocompatibility, mechanical properties).
    • Predicate Device Equivalence: The established safety and effectiveness of legally marketed predicate devices. The "ground truth" is that if the new device is sufficiently similar to a predicate device in termsally relevant characteristics (and any differences do not raise new safety/performance questions), then it is considered safe and effective.
    • Non-Clinical Test Results: Data from physical, chemical, mechanical, and biological (biocompatibility) tests proving that the device meets specified performance requirements outlined in the relevant standards.

    8. The Sample Size for the Training Set

    Not applicable. There is no "training set" as this is not an AI/ML device requiring data to learn patterns.


    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there is no training set.