Found 5 results

510(k) Data Aggregation

    K Number
    K241605

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-09-05

    (93 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K172009, P960025, K190165, K201267

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Adaptix™ PEEK Interbody System with Nanotechnology devices and the Capstone Control™ PEEK Spinal System with Nanotechnology devices including those with macro-, micro- and nano-roughened surface textures are intended for spinal fusion procedures in skeletally mature patients with degenerative disc disease (defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies) at one or two contiguous spinal levels from L2-S1. These patients should have had six months of nonoperative treatment. These patients may have had a previous non-fusion spinal surgery and/or may have up to Grade 1 spondylolisthesis or retrolisthesis at the involved spinal level(s).
    Additionally, Adaptix™ PEEK Interbody System with Nanotechnology and the Capstone Control™ PEEK Spinal System with Nanotechnology devices can be used as an adjunct to fusion in patients diagnosed with degenerative scoliosis. The Adaptix™ PEEK and the Capstone Control™ PEEK devices are to be used with autograft and/or allograft comprised of cancellous and/or corticocancellous bone graft and/or demineralized allograft bone with bone marrow aspirate. These implants are intended for use with supplemental fixation indicated for lumbar spinal fusion procedures and may be implanted via an open or a minimally invasive posterior approach and/or transforaminal approach.

    Device Description

    The Adaptix™ PEEK Interbody System with Nanotechnology and Capstone Control™ PEEK Spinal System with Nanotechnology consist of interbody implants designed for restoration of sagittal alignment in the lumbar spine. The upper and lower surfaces of the implant incorporate a three-dimensional titanium scaffold with interconnected pores averaging 523 μm, and pore interconnections averaging 229 μm in diameter. This product demonstrates the requirements for nanotechnology. The surface has been deliberately manipulated to produce nanoscale dimensions which exhibit specific properties. The scaffold of the Adaptix™ PEEK and Capstone Control™ PEEK devices is electrochemically treated to possess a controlled nanotopography composed of nanotube arrays having a pore size diameter between 30-90 nanometers. Calcium and phosphate are incorporated into the nanotube surface. The scaffold with nanotubes assists in securing the implant in the intervertebral space and provides radiographic confirmation of the implant location. The Adaptix™ PEEK and Capstone Control™ PEEK devices are available in a variety of sizes to accommodate the individual anatomic and clinical circumstances of each patient.

    AI/ML Overview

    The provided text describes a medical device, the Adaptix™ PEEK Interbody System with Nanotechnology and Capstone Control™ PEEK Spinal System with Nanotechnology, and its 510(k) submission for substantial equivalence to predicate devices. It does not present acceptance criteria or a study that proves the device meets those criteria in the context of an AI/ML powered medical device.

    The "Performance Data" section solely discusses mechanical and MR compatibility testing, which are standard for interbody fusion devices and not related to AI/ML performance.

    Therefore, I cannot extract the requested information about acceptance criteria and a study proving their fulfillment for an AI/ML device from the given document. The document pertains to a physical medical implant, not an AI/ML software.

    Ask a Question

    Ask a specific question about this device

    K Number
    K230478

    Validate with FDA (Live)

    Date Cleared
    2023-10-19

    (239 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K191537, K173148, K181963, K160125, K172009

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Acro Composites Interbody System is intended for interbody fusion. The devices are designed for use with autogenous and/or allogeneic bone graft comprised of cancellous and/or corticocancellous bone and/or demineralized allograft bone with bone marrow aspirate to facilitate fusion and are to be used with supplemental fixation cleared for the implanted level.
    The Acro Composites cervical devices are intended for anterior interbody fusion in skeletally mature patients who have had at least six weeks of non-operative treatment. The cervical devices are indicated to treat cervical disc degeneration and/or cervical spinal instability, as confirmed by imaging studies (radiographs, CT, MRI), that results in radiculopathy, myelopathy, and/or pain at multiple contiguous levels from C2-T1. The hyperlordotic implants (≥ 10°) are required to be used with an anterior cervical plate.
    The Acro Composites lumbar devices are indicated for use at one or two contiguous levels in the lumbar spine from L2-S1, in skeletally mature patients who have had at least six months of non-operative treatment. The lumbar devices are indicated to treat lumbar degenerative disc disease (DDD) with up to Grade 1 spondylolisthesis or retrolisthesis at the involved spinal level(s). DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by imaging studies (radiographs, CT, MRI). Additionally, the lumbar devices can be used as an adjunct to fusion in patients diagnosed with degenerative scoliosis. The hyperlordotic implants (≥ 20°) should be used with anterior supplemental fixation.

    Device Description

    The Acro Composites Interbody System includes interbody fusion devices for cervical and lumbar implantation manufactured from AcroPek – a carbon fiber reinforced PEKEKK polymer (CFRP) material. The implants are designed as a solid frame to provide surgical stabilization of the spine. Each interbody incorporates a central cavity that can be packed bone graft material. The implants are available in a variety of height, length, width and lordotic angulation combinations to accommodate the patient specific anatomy and clinical circumstances. The implants are sold sterile.

    AI/ML Overview

    The provided document is a 510(k) summary for the Acro Composites Interbody System, a medical device for spinal fusion. It details the device's indications for use, materials, and a declaration of substantial equivalence to predicate devices. However, this document does not describe an AI or software device study. It describes the mechanical performance testing of an intervertebral fusion device to demonstrate its safety and effectiveness.

    Therefore, most of the information requested in your prompt, which pertains to AI/software device studies (e.g., acceptance criteria for diagnostic performance, sample sizes for test/training sets, expert adjudication, MRMC studies, standalone performance, ground truth for AI), is not present in the provided text.

    Based on the information provided, here's what can be extracted:


    1. Table of acceptance criteria and the reported device performance:

    Acceptance Criteria (from predicate device comparison)Reported Device Performance (Acro Composites Interbody System)
    Static and Dynamic axial compression (ASTM F2077)Meet requirements of ASTM F2077
    Static and Dynamic compression-shear (ASTM F2077)Meet requirements of ASTM F2077
    Static and Dynamic torsion (ASTM F2077)Meet requirements of ASTM F2077
    Subsidence (ASTM F2267)Meet requirements of ASTM F2267

    Note: The reported device performance is stated as "The mechanical test results demonstrate that the Acro Composites Interbody System performance is substantially equivalent to the predicate devices" and that it aligns with the specified ASTM standards. Specific numerical values for acceptance criteria or performance are not provided in this summary.

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample Size: Not specified in the document. Mechanical testing typically involves a specific number of samples for each test type (e.g., several devices for compression, shear, and torsion).
    • Data Provenance: Not specified. These are laboratory-based mechanical tests, not clinical data from patients.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • Not applicable. This is not an AI/software device and does not involve human expert interpretation for "ground truth". The "ground truth" here is compliance with engineering standards (ASTM).

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not applicable. (See answer to point 3).

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • Not applicable. This is not an AI/software device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Not applicable. This is not an AI/software device.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • The "ground truth" in this context is compliance with established engineering and biocompatibility standards, specifically:
      • ASTM F2077 (Standard Test Methods for Static and Dynamic Axial Compression, Compression-Shear, and Torsion Testing of Spinal Implants)
      • ASTM F2267 (Standard Test Method for Measuring Load Between Parallel Platens for Intervertebral Body Fusion Devices)
      • ASTM F1876 (PEKEKK resin material standard)
      • ASTM B562 (Gold wire material standard)
      • ASTM F899 (Medical grade stainless steel material standard)

    8. The sample size for the training set

    • Not applicable. This is not an AI/software device and does not involve a "training set."

    9. How the ground truth for the training set was established

    • Not applicable. (See answer to point 8).

    Summary of what the document IS about:

    The document describes the submission of a 510(k) premarket notification for the Acro Composites Interbody System. The intent is to demonstrate "substantial equivalence" to existing, legally marketed predicate devices. This equivalence is primarily shown through:

    • Identical Intended Use: Interbody fusion for cervical and lumbar spine.
    • Similar Technological Characteristics: Basic design (structural column), material (reinforced polymer), and sizes comparable to predicate systems.
    • Performance Data: Mechanical testing (static & dynamic axial compression, compression-shear, torsion, and subsidence) was performed according to ASTM F2077 and F2267 standards. The results demonstrate that the device's performance is substantially equivalent to the predicate devices and meets these standards.
    Ask a Question

    Ask a specific question about this device

    K Number
    K222806

    Validate with FDA (Live)

    Date Cleared
    2022-12-22

    (97 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K161649, K170297, K172446, K172941, K172009, K162264

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Kodiak C Cervical Cages are indicated for use in skeletally mature patients with degenerative disc disease (DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies) of the cervical spine (C2-T1). The Kodiak C Cervical Cages are intended to be used with autograft and/or allograft bone (allogenic bone graft comprised of cancellous and/or corticocancellous bone graft). The Kodiak C Cervical Cages are intended to be used with an FDA cleared cervical supplemental fixation system. Patients should receive 6 weeks of nonoperative treatment prior to treatment.

    The Kodiak C Corpectomy Cages are indicated for use in the thoracolumbar spine (T1-L5) for partial or total replacement of a damaged, collapsed, or unstable vertebral body due to trauma/fracture or tumor, to achieve anterior decompression of the spinal cord and neural tissues, and to restore the height of a collapsed vertebral body. The Kodiak C Corpectomy Cages are intended to be used with autograft and/or allograft bone. The Kodiak C Corpectomy Cages are intended to be used with an FDA cleared supplemental fixation device such as a lumbar pedicle screw system.

    Device Description

    The Met One Technologies Kodiak C Cervical Cage is a cervical intervertebral body fusion device that is implanted into the vertebral body space to improve stability of the spine while supporting fusion. The cervical cages have a central cavity to permit the packing of autograft and/or allograft bone, teeth on the superior and inferior surfaces to resist expulsion, and lattice windows for radiographic visualization. The implants are additively manufactured from Ti-6A1-4V ELI and are available in a variety of height, footprints, and lordotic configurations to suit individual patient anatomy.
    The Met One Technologies Kodiak C Corpectomy Cage is a thoracolumbar vertebral body replacement device (VBR) that is implanted to achieve anterior decompression of the spinal cord and neural tissues and to restore the height of a collapsed vertebral body. The corpectomy cages have a central cavity to permit the packing of autograft and/or allograft bone, teeth on the superior and inferior surfaces to resist expulsion, and lattice windows for radiographic visualization. The implants are available in a variety of heights, footprints, and lordotic configurations to suit individual patient anatomy.

    AI/ML Overview

    This document is a 510(k) Summary for the Kodiak C Spinal Implant System, a medical device. It focuses on demonstrating substantial equivalence to predicate devices, rather than presenting a study proving performance against specific acceptance criteria in the context of AI/ML or diagnostic performance.

    Therefore, the information requested regarding acceptance criteria, study details (sample size, data provenance, expert qualification, adjudication, MRMC, standalone performance, ground truth), training set sample size, and ground truth establishment cannot be fully provided from the given document. This document describes mechanical and material testing, not diagnostic or AI performance.

    Here's an attempt to answer based on the provided text, highlighting what is present and what is missing:

    1. A table of acceptance criteria and the reported device performance

    The document lists performance tests conducted, but it does not explicitly state quantitative acceptance criteria or reported numerical performance values for these tests. It only states that the device "demonstrated substantial equivalence" to predicate devices, implying that the results met relevant industry standards (e.g., ASTM standards) but without providing the actual data or specific thresholds.

    Acceptance Criteria (Implicit)Reported Device Performance (Summary)
    Compliance with ASTM F2077 for Static CompressionDemonstrated substantial equivalence
    Compliance with ASTM F2077 for Dynamic CompressionDemonstrated substantial equivalence
    Compliance with ASTM F2077 for Static TorsionDemonstrated substantial equivalence
    Compliance with ASTM F2077 for Dynamic TorsionDemonstrated substantial equivalence
    Compliance with ASTM F2267 for SubsidenceDemonstrated substantial equivalence
    Expulsion resistanceDemonstrated substantial equivalence

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Test set sample size: Not specified. The document refers to "the following test modes" and implies mechanical testing of devices, not clinical studies with patient data.
    • Data provenance: Not applicable in the context of mechanical device testing. The tests are likely performed in a lab setting.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • Not applicable. This is a medical device approval involving mechanical properties and material composition, not diagnostic interpretation by experts. Ground truth in this context would refer to material specifications and engineering standards, not expert medical opinions.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not applicable. Adjudication methods are relevant for subjective interpretations of data, not for objective mechanical test results.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No. This document does not mention any MRMC study or AI assistance. The device is a physical spinal implant.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • No. This document does not pertain to an algorithm or AI.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • The "ground truth" for this type of device (spinal implant) would be established by engineering specifications, material standards (e.g., ASTM F3001 for Ti-6Al-4V ELI), and biomechanical testing standards (e.g., ASTM F2077, ASTM F2267). The device's performance is compared against these known, objective standards to demonstrate substantial equivalence to legally marketed predicate devices.

    8. The sample size for the training set

    • Not applicable. This document does not describe an AI/ML device that requires a training set.

    9. How the ground truth for the training set was established

    • Not applicable. This document does not describe an AI/ML device.
    Ask a Question

    Ask a specific question about this device

    K Number
    K221858

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2022-10-14

    (109 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K172009, K202488, K190959

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The ZSFab Lumbar Interbody System is intended for lumbar interbody fusion. The devices are indicated for use at one or two contiguous levels in the lumbar spine from L2-S1, in skeletally mature patients who have had at least six months of non-operative treatment. The ZSFab Lumbar Interbody System is indicated to treat lumbar degenerative disc disease (DDD) with up to Grade 1 spondylolisthesis or retrolisthesis at the involved spinal level(s). DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by imaging studies (radiographs, CT, MRI). Additionally, the ZSFab Lumbar Interbody System can be used as an adjunct to fusion in patients diagnosed with degenerative scoliosis. The ZSFab lumbar Interbody System is designed for use with autogenous and/or allogeneic bone graft comprised of cancellous and/or corticocancellous bone and/or demineralized allograft bone with bone marrow aspirate to facilitate fusion and to be used with supplemental fixation cleared for use in the lumbosacral spine.

    Device Description

    The ZSFab Lumbar Interbody System includes additively manufactured interbody fusion devices for lumbar implantation. The implants are designed as a solid frame that includes lattice structures to provide surgical stabilization of the spine. The lattices have near-elliptical pores with axis lengths of 610-1000µm. The endplates are featured with teeth design and stochastic lattice structures with average pore size of 620-710µm. Each lumbar interbody has a central cavity for bone graft material. The implants are available in a variety of height, length, width and lordotic angulation combinations to accommodate the patient specific anatomy and clinical circumstances. The implants are sold sterile.

    AI/ML Overview

    The provided document is a 510(k) summary for a medical device (ZSFab Lumbar Interbody System), which focuses on demonstrating substantial equivalence to existing predicate devices based on design, materials, and mechanical performance. It does not contain information about the performance of an AI/ML powered device, nor does it discuss clinical studies with human readers, ground truth establishment, or multi-reader multi-case (MRMC) studies as would be relevant for an AI/ML product.

    Therefore, I cannot extract the requested information regarding acceptance criteria and a study proving device meets those criteria in the context of an AI/ML device. The document primarily describes pre-clinical (mechanical) testing of a spinal implant.

    Ask a Question

    Ask a specific question about this device

    K Number
    K191791

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2019-09-25

    (84 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K120991, K111569, K151310, K162103, K172009

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The TranS1 Interbody Fusion System is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2-S1. DDD is defined as discogenic back pain with degeneration of the disc confirmed by patient history and radiographic studies. These DDD patients may also have up to Grade I spondylolisthesis or retrolisthesis at the involved level(s). The TranS1 Interbody Fusion System can be used as an adjunct to fusion in patients diagnosed with degenerative scoliosis. These patients should have had six months of non-operative treatment. The TranS1 Interbody Fusion System is designed to be used with autograft and/or allograft comprised of cancellous and/or coricocancellous bone graft, and a supplemental spinal fixation system that is cleared for use in the lumbar spine.

    Device Description

    The TranS1 Interbody Fusion System is used to provide structural stability and maintain disc space distraction in skeletally mature adults requiring intervertebral body fusion. The devices are designed to be used in conjunction with supplemental spinal fixation instrumentation. The subject devices are multiple component systems comprised of single-use implants designed to treat the lumbar spine.

    The TranS1 Interbody Fusion System lumbar implants are fabricated from PEEK (ASTM F2026) with Tantalum (ASTM F560) x-ray markers. The TranS1 Interbody Fusion System implants are available in a range of sizes and shapes, and are designed to accommodate variations in surgical approach and patient anatomy. Each cage has a hollow center to allow placement of autograft and/or allograft comprised of cancellous and/or corticocancellous bone graft. Ridges on the superior and inferior surfaces of the device help to grip the endplates and prevent expulsion.

    AI/ML Overview

    I am sorry, but the provided text only discusses the FDA's 510(k) clearance for the TranS1 Interbody Fusion System, which is a medical device used for spinal fusion procedures. It specifies the intended use, material composition, and references performance testing conducted according to ASTM standards for static and dynamic mechanical properties, as well as subsidence and expulsion.

    However, the text does not contain any information about an AI/ML powered device, acceptance criteria related to AI/ML performance metrics (e.g., accuracy, sensitivity, specificity), or any study details proving an AI/ML device meets such criteria.

    Therefore, I cannot fulfill your request for information about:

    1. A table of acceptance criteria and reported device performance for an AI/ML device.
    2. Sample sizes and data provenance for a test set for an AI/ML device.
    3. Number and qualifications of experts for AI/ML ground truth.
    4. Adjudication method for an AI/ML test set.
    5. MRMC study for an AI/ML device.
    6. Standalone performance for an AI/ML algorithm.
    7. Type of ground truth used for an AI/ML device.
    8. Sample size for the training set for an AI/ML device.
    9. How ground truth was established for the training set for an AI/ML device.