510(k) Data Aggregation

    K Number
    K173713

    Validate with FDA (Live)

    Date Cleared
    2018-03-08

    (94 days)

    Product Code
    Regulation Number
    892.1550
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K152962, K153529, K163691, K162094

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The HS70A Diagnostic Ultrasound System and transducers are intended for diagnostic ultrasound imaging and fluid analysis of the human body.

    The clinical applications include: Fetal/Obstetrics, Abdominal, Gynecology, Intra-operative, Small Organ, Neonatal Cephalic, Adult Cephalic, Trans-rectal, Trans-esoph. (non-Cardiac), Muscular-Skeletal (Conventional, Superficial), Urology, Cardiac Adult, Cardiac Pediatric, Trans-esophageal (Cardiac) and Peripheral vessel.

    Device Description

    The HS70A is a general purpose, mobile, software controlled, diagnostic ultrasound system. Its function is to acquire ultrasound data and to display the data as 2D mode, M mode, Color Doppler imaging, Power Doppler imaging (including Directional Power Doppler mode; S-Flow), PW Spectral Doppler mode, CW Spectral Doppler mode, Harmonic imaging(S-Harmonic), Tissue Doppler imaging, Tissue Doppler Wave, 3D imaging mode (real-time 4D imaging mode), Elastoscan Mode or as a combination of these modes. The HS70A also gives the operator the ability to measure anatomical structures and offers analysis packages that provide information that is used to make a diagnosis by competent health care professionals. The HS70A has real time acoustic output display with two basic indices, a mechanical index and a thermal index, which are both automatically displayed.

    AI/ML Overview

    This document is a 510(k) Premarket Notification for the SAMSUNG MEDISON Co., Ltd. HS70A Diagnostic Ultrasound System. It details the device's intended use, technology, and comparison to predicate devices, but does not include acceptance criteria or the results of a study proving the device meets acceptance criteria related to diagnostic performance.

    The document refers to non-clinical tests for safety and compliance with various standards but explicitly states: "The subject of this premarket submission, HS70A, is not required clinical studies to support substantial equivalence." This means that no clinical performance study was conducted or reported in this submission to evaluate the diagnostic accuracy of the device.

    Therefore, the requested information regarding acceptance criteria and the study proving device performance related to diagnostic accuracy cannot be extracted from the provided text.

    Based on the provided text, here is what can be inferred about the criteria and tests performed for regulatory submission:

    1. A table of acceptance criteria and the reported device performance:

    Since no clinical studies proving diagnostic performance were conducted or reported, no such table can be provided. The document focuses on regulatory compliance and safety standards.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective):

    Not applicable as no clinical test set for diagnostic performance was used or reported in this submission. The tests performed were non-clinical for safety and electrical compatibility.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience):

    Not applicable as no clinical ground truth was established or reported in this submission.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    Not applicable as no clinical test set was used or reported in this submission.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    Not applicable as implied by the statement "The subject of this premarket submission, HS70A, is not required clinical studies to support substantial equivalence." The device is a diagnostic ultrasound system and not explicitly stated to include AI for diagnostic assistance. There is a mention of "E-Strain, S-Detect for Breast, and S-Detect for Thyroid" which are described as "same functionalities in the predicate RS80A," suggesting image processing features rather than a separate AI-driven diagnostic interpretation system that would typically warrant an MRMC study.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done:

    Not applicable as no diagnostic standalone algorithm performance study was reported.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc):

    Not applicable. For the non-clinical tests conducted, the "ground truth" would be the specifications and requirements of the various safety and performance standards (e.g., IEC 60601-1, NEMA UD 2-2004).

    8. The sample size for the training set:

    Not applicable as no machine learning algorithm development training set is mentioned or implied for diagnostic performance.

    9. How the ground truth for the training set was established:

    Not applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    K170493

    Validate with FDA (Live)

    Date Cleared
    2017-03-28

    (39 days)

    Product Code
    Regulation Number
    892.1550
    Reference & Predicate Devices
    Why did this record match?
    Reference Devices :

    K143264, K162094, K153529, K153408, K163691

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The HS50 / HS60 Diagnostic Ultrasound System and transducers are intended for diagnostic ultrasound imaging and fluid analysis of the human body.

    The clinical applications include: Fetal/Obstetrics, Abdominal, Gynecology, Pediatric, Small Organ, Neonatal Cephalic, Adult Cephalic, Trans-rectal, Muscular-Skeletal (Conventional, Superficial), Urology, Cardiac Adult, Cardiac Pediatric and Peripheral vessel.

    Device Description

    The HS50 / HS60 is a general purpose, mobile, software controlled, diagnostic ultrasound system. Its function is to acquire ultrasound data and to display the data as B mode, M mode, Color M mode, Anatomical mode, Color Doppler mode, Pulsed Wave (PW) Spectral Doppler mode, Continuous Wave (CW) Doppler mode, Tissue Doppler Imaging (TDI) mode, Tissue Doppler Wave (TDW) mode, Power Doppler (PD) mode, ElastoScan Mode, 3D/4D/XI STIC imaging mode, Dual mode, Quad mode, Combined mode, Simultaneous mode and Zoom mode. The HS50 and HS60 also gives the operator the ability to measure anatomical structures and offers analysis packages that provide information that is used to make a diagnosis by competent health care professionals. The HS50 / HS60 have real time acoustic output display with two basic indices, a mechanical index and a thermal index, which are both automatically displayed.

    AI/ML Overview

    The provided text is a 510(k) summary for the Samsung Medison HS50/HS60 Diagnostic Ultrasound System. It focuses on demonstrating substantial equivalence to predicate devices rather than proving a device meets specific performance acceptance criteria for a new clinical claim. Therefore, much of the requested information regarding acceptance criteria and a study proving their fulfillment is not directly available in this document.

    However, I can extract information related to the device's technical characteristics and the general safety and effectiveness assessments.

    Summary of Device Features and Equivalence:

    The HS50/HS60 Diagnostic Ultrasound System is a general-purpose, mobile, software-controlled diagnostic ultrasound system. It acquires ultrasound data and displays it in various modes (B, M, Color M, Anatomical, Color Doppler, Pulsed Wave (PW) Spectral Doppler, Continuous Wave (CW) Doppler, Tissue Doppler Imaging (TDI), Tissue Doppler Wave (TDW), Power Doppler (PD), ElastoScan, 3D/4D/XI STIC imaging, Dual, Quad, Combined, Simultaneous, and Zoom modes). It also provides measurement and analysis packages for diagnostic purposes.

    The device's substantial equivalence to predicate devices (H60 (K143264), RS80A (K162094), WS80A (K153529), HM70A (K153408), and HS70A (K163691)) is claimed based on safety, effectiveness, and functionality. All systems transmit ultrasonic energy into patients, process echoes for display of anatomic structures and fluid flow, and allow for measurements and calculations.


    Here's the information formatted to the best of my ability based on the provided text, acknowledging that direct "acceptance criteria" and "study results" in the sense of a new clinical claim are not present for this type of submission:

    1. A table of acceptance criteria and the reported device performance

    The document does not specify quantitative acceptance criteria for a new clinical performance claim, as it is a 510(k) submission for substantial equivalence to existing devices. The "performance" is implicitly deemed equivalent if the device meets all safety standards and performs its intended functions similarly to the predicate devices.

    Acceptance Criteria (Implied for Substantial Equivalence to Predicate Devices)Reported Device Performance (HS50 / HS60 Ultrasound System)
    Safety and Effectiveness"The HS50 / HS60 is a general purpose, mobile, software controlled, diagnostic ultrasound system."
    Consistent intended uses with predicate devices."The HS50 / HS60 Diagnostic Ultrasound System and transducers are intended for diagnostic ultrasound imaging and fluid analysis of the human body." Clinical applications listed are identical to those of predicate devices: Fetal/Obstetrics, Abdominal, Gynecology, Pediatric, Small Organ, Neonatal Cephalic, Adult Cephalic, Trans-rectal, Trans-vaginal, Muscular-Skeletal (Conventional, Superficial), Urology, Cardiac Adult, Cardiac Pediatric and Peripheral vessel.
    Similar technological characteristics (modes, scanhead types, frequencies).The comparison table on pages 22-23 explicitly states that HS50/HS60 supports all modes of operation (B-mode, M-mode, PW Spectral Doppler, CW Doppler, Color Doppler, Power Amplitude Doppler, Tissue Harmonic Imaging, 3D/4D imaging mode, Combined modes) and transducer types (linear, curved linear, endocavity, phased array, static probes) and frequency ranges (1.0 ~ 20.0 MHz) as the identified predicate devices.
    Compliance with relevant safety standards (electrical, acoustic, biocompatibility, EMC)."The device has been evaluated for acoustic output, biocompatibility effectiveness as well as thermal, electrical, electromagnetic and mechanical safety and has been found to conform to applicable medical device safety standards." Specific standards listed include IEC 60601-1, IEC 60601-1-2, IEC 60601-2-37, ISO 10993-1, ISO 10993-5, ISO 10993-10, ISO 14971, NEMA UD 2-2004, NEMA UD 3-2004.
    Similar functionality.The comparison table on pages 22-23 lists various functionalities (Quick Scan, ClearVision, MultiVision, Needle Mate+, Auto IMT+, Strain+, ElastoScan, Panoramic, 3D Imaging (Volume Data Acquisition), 3D Imaging Presentation, 3D Cine/4D Cine, 3D Rendering MPR, 3D XI, 3D MSV/Oblique View, 3D MXI Volume Slice/Mirror View, Volume CT, 3D MagiCut, Volume Calculation (VOCAL, XI VOCAL), XI STIC, HDVI, Realistic Vue, Ez Exam+, CEUS+, 5D NT, 5D Follicle) and marks them as present ("V") in the subject devices (HS50/HS60) and their predicate devices.

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document explicitly states: "Summary of Clinical Tests: Not applicable. The subject of this submission, HS50 / HS60, did not require clinical studies to support substantial equivalence." Therefore, there is no test set sample size, data provenance, or details of a clinical study to report from this document.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    Not applicable, as no clinical studies were performed for this 510(k) submission.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable, as no clinical studies were performed.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is a 510(k) for a diagnostic ultrasound system, not an AI-based interpretation device claiming improved reader performance. The document explicitly states "Not applicable. The subject of this submission, HS50 / HS60, did not require clinical studies to support substantial equivalence."

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is a diagnostic ultrasound system, which is a human-operated device, not a standalone algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    Not applicable, as no clinical studies were performed for a new performance claim. The ground for substantial equivalence relies on comparison to predicate devices, which are already cleared for clinical use.

    8. The sample size for the training set

    Not applicable. This document is for a medical device (ultrasound system), not an AI algorithm requiring a training set in the typical sense for machine learning.

    9. How the ground truth for the training set was established

    Not applicable.